TYPE ReportEIRVars
  REAL(r64)    :: ChillerPartLoadRatio  = 0.0d0 ! reporting: Chiller PLR (Load/Capacity)
  REAL(r64)    :: ChillerCyclingRatio   = 0.0d0 ! reporting: Chiller cycling ratio (time on/time step)
  REAL(r64)    :: ChillerFalseLoadRate  = 0.0d0 ! reporting: Chiller false load over and above water side load [J]
  REAL(r64)    :: ChillerFalseLoad      = 0.0d0 ! reporting: Chiller false load over and above water side load [W]
  REAL(r64)    :: Power                 = 0.0d0 ! reporting: Chiller power, W
  REAL(r64)    :: QEvap                 = 0.0d0 ! reporting: Evaporator heat transfer rate [W]
  REAL(r64)    :: QCond                 = 0.0d0 ! reporting: Condenser heat transfer rate [W]
  REAL(r64)    :: Energy                = 0.0d0 ! reporting: Chiller electric consumption [J]
  REAL(r64)    :: EvapEnergy            = 0.0d0 ! reporting: Evaporator heat transfer energy [J]
  REAL(r64)    :: CondEnergy            = 0.0d0 ! reporting: Condenser heat transfer energy [J]
  REAL(r64)    :: CondInletTemp         = 0.0d0 ! reporting: Condenser inlet temperature [C]
  REAL(r64)    :: EvapInletTemp         = 0.0d0 ! reporting: Evaporator inlet temperature [C]
  REAL(r64)    :: CondOutletTemp        = 0.0d0 ! reporting: Condenser outlet temperature [C]
  REAL(r64)    :: EvapOutletTemp        = 0.0d0 ! reporting: Evaporator outlet temperature [C]
  REAL(r64)    :: Evapmdot              = 0.0d0 ! reporting: Evaporator mass flow rate [kg/s]
  REAL(r64)    :: Condmdot              = 0.0d0 ! reporting: Condenser mass flow rate [kg/s]
  REAL(r64)    :: ActualCOP             = 0.0d0 ! reporting: Coefficient of performance
  REAL(r64)    :: QHeatRecovery         = 0.0d0 ! reporting: Heat recovered from water-cooled condenser [W]
  REAL(r64)    :: EnergyHeatRecovery    = 0.0d0 ! reporting: Energy recovered from water-cooled condenser [J]
  REAL(r64)    :: HeatRecInletTemp      = 0.0d0 ! reporting: Heat reclaim inlet temperature [C]
  REAL(r64)    :: HeatRecOutletTemp     = 0.0d0 ! reporting: Heat reclaim outlet temperature [C]
  REAL(r64)    :: HeatRecMassFlow       = 0.0d0 ! reporting: Heat reclaim mass flow rate [kg/s]
  REAL(r64)    :: ChillerCondAvgTemp    = 0.d0  ! reporting: average condenser temp for curves with Heat recovery [C]
  REAL(r64)    :: ChillerCapFT          = 0.0d0 ! reporting: Chiller capacity curve output value
  REAL(r64)    :: ChillerEIRFT          = 0.0d0 ! reporting: Chiller EIRFT curve output value
  REAL(r64)    :: ChillerEIRFPLR        = 0.0d0 ! reporting: Chiller EIRFPLR curve output value
  REAL(r64)    :: CondenserFanPowerUse  = 0.0d0 ! reporting: Air-cooled condenser fan power [W]
  REAL(r64)    :: CondenserFanEnergyConsumption = 0.0d0 ! reporting: Air-cooled condenser fan energy [J]
  REAL(r64)    :: BasinHeaterPower       = 0.0d0  ! Basin heater power (W)
  REAL(r64)    :: BasinHeaterConsumption = 0.0d0  ! Basin heater energy consumption (J)
END TYPE ReportEIRVars