sourcefile~~hvacunitarybypassvav.f90~~EfferentGraph sourcefile~hvacunitarybypassvav.f90 HVACUnitaryBypassVAV.f90 sourcefile~datahvacglobals.f90 DataHVACGlobals.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~hvacfancomponent.f90 HVACFanComponent.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacfancomponent.f90 sourcefile~hvachxassistedcoolingcoil.f90 HVACHXAssistedCoolingCoil.f90 sourcefile~datahvacglobals.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~datazoneequipment.f90 DataZoneEquipment.f90 sourcefile~datahvacglobals.f90->sourcefile~datazoneequipment.f90 sourcefile~hvacheatingcoils.f90 HVACHeatingCoils.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacheatingcoils.f90 sourcefile~mixedair.f90 MixedAir.f90 sourcefile~datahvacglobals.f90->sourcefile~mixedair.f90 sourcefile~hvacwatercoilcomponent.f90 HVACWaterCoilComponent.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dxcoil.f90 DXCoil.f90 sourcefile~datahvacglobals.f90->sourcefile~dxcoil.f90 sourcefile~general.f90 General.f90 sourcefile~datahvacglobals.f90->sourcefile~general.f90 sourcefile~hvacsteamcoilcomponent.f90 HVACSteamCoilComponent.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~heatrecovery.f90 HeatRecovery.f90 sourcefile~datahvacglobals.f90->sourcefile~heatrecovery.f90 sourcefile~runtimelanguageprocessor.f90 RuntimeLanguageProcessor.f90 sourcefile~datahvacglobals.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~refrigeratedcase.f90 RefrigeratedCase.f90 sourcefile~datahvacglobals.f90->sourcefile~refrigeratedcase.f90 sourcefile~watermanager.f90 WaterManager.f90 sourcefile~datahvacglobals.f90->sourcefile~watermanager.f90 sourcefile~hvacunitarysystem.f90 HVACUnitarySystem.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacunitarysystem.f90 sourcefile~desiccantdehumidifiers.f90 DesiccantDehumidifiers.f90 sourcefile~datahvacglobals.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~hvacdxsystem.f90 HVACDXSystem.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacdxsystem.f90 sourcefile~photovoltaicthermalcollectors.f90 PhotovoltaicThermalCollectors.f90 sourcefile~datahvacglobals.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~hvacevapcomponent.f90 HVACEvapComponent.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacevapcomponent.f90 sourcefile~hvactranspiredcollector.f90 HVACTranspiredCollector.f90 sourcefile~datahvacglobals.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~hvacwatertoair.f90 HVACWatertoAir.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacwatertoair.f90 sourcefile~setpointmanager.f90 SetPointManager.f90 sourcefile~datahvacglobals.f90->sourcefile~setpointmanager.f90 sourcefile~branchinputmanager.f90 BranchInputManager.f90 sourcefile~datahvacglobals.f90->sourcefile~branchinputmanager.f90 sourcefile~hvacwatertoairmultispeedhp.f90 HVACWatertoAirMultiSpeedHP.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~packagedthermalstoragecoil.f90 PackagedThermalStorageCoil.f90 sourcefile~datahvacglobals.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~plantwaterthermaltank.f90 PlantWaterThermalTank.f90 sourcefile~datahvacglobals.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~plantsolarcollectors.f90 PlantSolarCollectors.f90 sourcefile~datahvacglobals.f90->sourcefile~plantsolarcollectors.f90 sourcefile~standardratings.f90 StandardRatings.f90 sourcefile~datahvacglobals.f90->sourcefile~standardratings.f90 sourcefile~hvacfancomponent.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~hvacfancomponent.f90->sourcefile~mixedair.f90 sourcefile~hvacfancomponent.f90->sourcefile~dxcoil.f90 sourcefile~hvacfancomponent.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvacfancomponent.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~hvacfancomponent.f90->sourcefile~hvacevapcomponent.f90 sourcefile~hvacfancomponent.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~hvachxassistedcoolingcoil.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~hvachxassistedcoolingcoil.f90->sourcefile~mixedair.f90 sourcefile~hvachxassistedcoolingcoil.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvachxassistedcoolingcoil.f90->sourcefile~hvacdxsystem.f90 sourcefile~datazoneequipment.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~datazoneequipment.f90->sourcefile~hvacfancomponent.f90 sourcefile~datazoneequipment.f90->sourcefile~mixedair.f90 sourcefile~datazoneequipment.f90->sourcefile~refrigeratedcase.f90 sourcefile~datazoneequipment.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datazoneequipment.f90->sourcefile~hvacevapcomponent.f90 sourcefile~userdefinedcomponents.f90 UserDefinedComponents.f90 sourcefile~datazoneequipment.f90->sourcefile~userdefinedcomponents.f90 sourcefile~datazoneequipment.f90->sourcefile~setpointmanager.f90 sourcefile~datazoneequipment.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~datazoneequipment.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~heatbalanceconvectioncoeffs.f90 HeatBalanceConvectionCoeffs.f90 sourcefile~datazoneequipment.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~plantutilities.f90 PlantUtilities.f90 sourcefile~plantutilities.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~plantutilities.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~plantutilities.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~plantutilities.f90->sourcefile~refrigeratedcase.f90 sourcefile~plantutilities.f90->sourcefile~hvacunitarysystem.f90 sourcefile~plantutilities.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~plantutilities.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~plantutilities.f90->sourcefile~userdefinedcomponents.f90 sourcefile~plantutilities.f90->sourcefile~hvacwatertoair.f90 sourcefile~plantutilities.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~plantutilities.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~plantutilities.f90->sourcefile~plantsolarcollectors.f90 sourcefile~datasizing.f90 DataSizing.f90 sourcefile~datasizing.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~datasizing.f90->sourcefile~hvacfancomponent.f90 sourcefile~datasizing.f90->sourcefile~datazoneequipment.f90 sourcefile~datasizing.f90->sourcefile~plantutilities.f90 sourcefile~datasizing.f90->sourcefile~hvacheatingcoils.f90 sourcefile~datasizing.f90->sourcefile~mixedair.f90 sourcefile~datasizing.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~datasizing.f90->sourcefile~dxcoil.f90 sourcefile~dataplant.f90 DataPlant.f90 sourcefile~datasizing.f90->sourcefile~dataplant.f90 sourcefile~datasizing.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~inputprocessor.f90 InputProcessor.f90 sourcefile~datasizing.f90->sourcefile~inputprocessor.f90 sourcefile~datasizing.f90->sourcefile~heatrecovery.f90 sourcefile~datasizing.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datasizing.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~datasizing.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~datasizing.f90->sourcefile~hvacevapcomponent.f90 sourcefile~datasizing.f90->sourcefile~hvacwatertoair.f90 sourcefile~datasizing.f90->sourcefile~branchinputmanager.f90 sourcefile~datasizing.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~datasizing.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~datasizing.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~emsmanager.f90 EMSManager.f90 sourcefile~emsmanager.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~emsmanager.f90->sourcefile~hvacfancomponent.f90 sourcefile~emsmanager.f90->sourcefile~hvacheatingcoils.f90 sourcefile~emsmanager.f90->sourcefile~mixedair.f90 sourcefile~emsmanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~emsmanager.f90->sourcefile~dxcoil.f90 sourcefile~emsmanager.f90->sourcefile~heatrecovery.f90 sourcefile~emsmanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~emsmanager.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~emsmanager.f90->sourcefile~hvacdxsystem.f90 sourcefile~emsmanager.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~emsmanager.f90->sourcefile~hvacevapcomponent.f90 sourcefile~emsmanager.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~emsmanager.f90->sourcefile~userdefinedcomponents.f90 sourcefile~emsmanager.f90->sourcefile~setpointmanager.f90 sourcefile~datainterfaces.f90 DataInterfaces.f90 sourcefile~datainterfaces.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~datainterfaces.f90->sourcefile~hvacfancomponent.f90 sourcefile~datainterfaces.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~datainterfaces.f90->sourcefile~datazoneequipment.f90 sourcefile~datainterfaces.f90->sourcefile~plantutilities.f90 sourcefile~datainterfaces.f90->sourcefile~emsmanager.f90 sourcefile~datainterfaces.f90->sourcefile~hvacheatingcoils.f90 sourcefile~reportsizingmanager.f90 ReportSizingManager.f90 sourcefile~datainterfaces.f90->sourcefile~reportsizingmanager.f90 sourcefile~datainterfaces.f90->sourcefile~mixedair.f90 sourcefile~dataenvironment.f90 DataEnvironment.f90 sourcefile~datainterfaces.f90->sourcefile~dataenvironment.f90 sourcefile~psychroutines.f90 PsychRoutines.f90 sourcefile~datainterfaces.f90->sourcefile~psychroutines.f90 sourcefile~branchnodeconnections.f90 BranchNodeConnections.f90 sourcefile~datainterfaces.f90->sourcefile~branchnodeconnections.f90 sourcefile~schedulemanager.f90 ScheduleManager.f90 sourcefile~datainterfaces.f90->sourcefile~schedulemanager.f90 sourcefile~datainterfaces.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~datainterfaces.f90->sourcefile~dxcoil.f90 sourcefile~datainterfaces.f90->sourcefile~general.f90 sourcefile~datainterfaces.f90->sourcefile~dataplant.f90 sourcefile~nodeinputmanager.f90 NodeInputManager.f90 sourcefile~datainterfaces.f90->sourcefile~nodeinputmanager.f90 sourcefile~datainterfaces.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~fluidproperties.f90 FluidProperties.f90 sourcefile~datainterfaces.f90->sourcefile~fluidproperties.f90 sourcefile~datainterfaces.f90->sourcefile~inputprocessor.f90 sourcefile~curvemanager.f90 CurveManager.f90 sourcefile~datainterfaces.f90->sourcefile~curvemanager.f90 sourcefile~datainterfaces.f90->sourcefile~heatrecovery.f90 sourcefile~dataheatbalance.f90 DataHeatBalance.f90 sourcefile~datainterfaces.f90->sourcefile~dataheatbalance.f90 sourcefile~datainterfaces.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~outputprocessor.f90 OutputProcessor.f90 sourcefile~datainterfaces.f90->sourcefile~outputprocessor.f90 sourcefile~outairnodemanager.f90 OutAirNodeManager.f90 sourcefile~datainterfaces.f90->sourcefile~outairnodemanager.f90 sourcefile~dataruntimelanguage.f90 DataRuntimeLanguage.f90 sourcefile~datainterfaces.f90->sourcefile~dataruntimelanguage.f90 sourcefile~sqlitefortranroutines.f90 SQLiteFortranRoutines.f90 sourcefile~datainterfaces.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~globalnames.f90 GlobalNames.f90 sourcefile~datainterfaces.f90->sourcefile~globalnames.f90 sourcefile~datainterfaces.f90->sourcefile~refrigeratedcase.f90 sourcefile~datainterfaces.f90->sourcefile~watermanager.f90 sourcefile~faultsmanager.f90 FaultsManager.f90 sourcefile~datainterfaces.f90->sourcefile~faultsmanager.f90 sourcefile~datainterfaces.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datainterfaces.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~datainterfaces.f90->sourcefile~hvacdxsystem.f90 sourcefile~datainterfaces.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~datainterfaces.f90->sourcefile~hvacevapcomponent.f90 sourcefile~datainterfaces.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~datainterfaces.f90->sourcefile~userdefinedcomponents.f90 sourcefile~datainterfaces.f90->sourcefile~hvacwatertoair.f90 sourcefile~datainterfaces.f90->sourcefile~setpointmanager.f90 sourcefile~datainterfaces.f90->sourcefile~branchinputmanager.f90 sourcefile~datainterfaces.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~datainterfaces.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~datainterfaces.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~datainterfaces.f90->sourcefile~plantsolarcollectors.f90 sourcefile~datainterfaces.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~vectorutilities.f90 VectorUtilities.f90 sourcefile~datainterfaces.f90->sourcefile~vectorutilities.f90 sourcefile~datainterfaces.f90->sourcefile~standardratings.f90 sourcefile~datazonecontrols.f90 DataZoneControls.f90 sourcefile~datazonecontrols.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~datazonecontrols.f90->sourcefile~emsmanager.f90 sourcefile~datazonecontrols.f90->sourcefile~mixedair.f90 sourcefile~datazonecontrols.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datazonecontrols.f90->sourcefile~setpointmanager.f90 sourcefile~hvacheatingcoils.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~hvacheatingcoils.f90->sourcefile~mixedair.f90 sourcefile~hvacheatingcoils.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvacheatingcoils.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacfancomponent.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacheatingcoils.f90 sourcefile~reportsizingmanager.f90->sourcefile~mixedair.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~reportsizingmanager.f90->sourcefile~dxcoil.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~reportsizingmanager.f90->sourcefile~heatrecovery.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~reportsizingmanager.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacevapcomponent.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacwatertoair.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~reportsizingmanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~reportsizingmanager.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataloopnode.f90 DataLoopNode.f90 sourcefile~dataloopnode.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~dataloopnode.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataloopnode.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~dataloopnode.f90->sourcefile~datazoneequipment.f90 sourcefile~dataloopnode.f90->sourcefile~plantutilities.f90 sourcefile~dataloopnode.f90->sourcefile~emsmanager.f90 sourcefile~dataloopnode.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataloopnode.f90->sourcefile~mixedair.f90 sourcefile~dataloopnode.f90->sourcefile~branchnodeconnections.f90 sourcefile~dataloopnode.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataloopnode.f90->sourcefile~dxcoil.f90 sourcefile~dataloopnode.f90->sourcefile~dataplant.f90 sourcefile~dataloopnode.f90->sourcefile~nodeinputmanager.f90 sourcefile~dataloopnode.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~dataloopnode.f90->sourcefile~curvemanager.f90 sourcefile~dataloopnode.f90->sourcefile~heatrecovery.f90 sourcefile~dataloopnode.f90->sourcefile~outairnodemanager.f90 sourcefile~dataloopnode.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataloopnode.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataloopnode.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~dataloopnode.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataloopnode.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~dataloopnode.f90->sourcefile~hvacevapcomponent.f90 sourcefile~dataloopnode.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~dataloopnode.f90->sourcefile~userdefinedcomponents.f90 sourcefile~dataloopnode.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataloopnode.f90->sourcefile~setpointmanager.f90 sourcefile~dataloopnode.f90->sourcefile~branchinputmanager.f90 sourcefile~dataloopnode.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataloopnode.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataloopnode.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataloopnode.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataloopnode.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~dataairsystems.f90 DataAirSystems.f90 sourcefile~dataairsystems.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~dataairsystems.f90->sourcefile~emsmanager.f90 sourcefile~dataairsystems.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataairsystems.f90->sourcefile~mixedair.f90 sourcefile~dataairsystems.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataairsystems.f90->sourcefile~dxcoil.f90 sourcefile~dataairsystems.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataairsystems.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~dataairsystems.f90->sourcefile~hvacevapcomponent.f90 sourcefile~dataairsystems.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataairsystems.f90->sourcefile~setpointmanager.f90 sourcefile~dataairsystems.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataairsystems.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~mixedair.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~dataenvironment.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~dataenvironment.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataenvironment.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataenvironment.f90->sourcefile~mixedair.f90 sourcefile~dataenvironment.f90->sourcefile~psychroutines.f90 sourcefile~dataenvironment.f90->sourcefile~schedulemanager.f90 sourcefile~dataenvironment.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataenvironment.f90->sourcefile~dxcoil.f90 sourcefile~dataenvironment.f90->sourcefile~nodeinputmanager.f90 sourcefile~dataenvironment.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~dataenvironment.f90->sourcefile~heatrecovery.f90 sourcefile~dataenvironment.f90->sourcefile~dataheatbalance.f90 sourcefile~dataenvironment.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~dataenvironment.f90->sourcefile~outputprocessor.f90 sourcefile~dataenvironment.f90->sourcefile~outairnodemanager.f90 sourcefile~dataenvironment.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~dataenvironment.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataenvironment.f90->sourcefile~watermanager.f90 sourcefile~dataenvironment.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataenvironment.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~dataenvironment.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataenvironment.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~dataenvironment.f90->sourcefile~hvacevapcomponent.f90 sourcefile~dataenvironment.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~dataenvironment.f90->sourcefile~userdefinedcomponents.f90 sourcefile~dataenvironment.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataenvironment.f90->sourcefile~setpointmanager.f90 sourcefile~dataenvironment.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataenvironment.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataenvironment.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataenvironment.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataenvironment.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~psychroutines.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~psychroutines.f90->sourcefile~hvacfancomponent.f90 sourcefile~psychroutines.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~psychroutines.f90->sourcefile~hvacheatingcoils.f90 sourcefile~psychroutines.f90->sourcefile~mixedair.f90 sourcefile~psychroutines.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~psychroutines.f90->sourcefile~dxcoil.f90 sourcefile~psychroutines.f90->sourcefile~nodeinputmanager.f90 sourcefile~psychroutines.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~psychroutines.f90->sourcefile~heatrecovery.f90 sourcefile~psychroutines.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~psychroutines.f90->sourcefile~outairnodemanager.f90 sourcefile~psychroutines.f90->sourcefile~refrigeratedcase.f90 sourcefile~psychroutines.f90->sourcefile~hvacunitarysystem.f90 sourcefile~psychroutines.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~psychroutines.f90->sourcefile~hvacdxsystem.f90 sourcefile~psychroutines.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~psychroutines.f90->sourcefile~hvacevapcomponent.f90 sourcefile~psychroutines.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~psychroutines.f90->sourcefile~userdefinedcomponents.f90 sourcefile~psychroutines.f90->sourcefile~hvacwatertoair.f90 sourcefile~psychroutines.f90->sourcefile~setpointmanager.f90 sourcefile~psychroutines.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~psychroutines.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~psychroutines.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~psychroutines.f90->sourcefile~plantsolarcollectors.f90 sourcefile~psychroutines.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~datazoneenergydemands.f90 DataZoneEnergyDemands.f90 sourcefile~datazoneenergydemands.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~datazoneenergydemands.f90->sourcefile~mixedair.f90 sourcefile~datazoneenergydemands.f90->sourcefile~refrigeratedcase.f90 sourcefile~datazoneenergydemands.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datazoneenergydemands.f90->sourcefile~hvacevapcomponent.f90 sourcefile~datazoneenergydemands.f90->sourcefile~userdefinedcomponents.f90 sourcefile~datazoneenergydemands.f90->sourcefile~setpointmanager.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacfancomponent.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~branchnodeconnections.f90->sourcefile~datazoneequipment.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacheatingcoils.f90 sourcefile~branchnodeconnections.f90->sourcefile~mixedair.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~branchnodeconnections.f90->sourcefile~dxcoil.f90 sourcefile~branchnodeconnections.f90->sourcefile~nodeinputmanager.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~branchnodeconnections.f90->sourcefile~heatrecovery.f90 sourcefile~branchnodeconnections.f90->sourcefile~refrigeratedcase.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacunitarysystem.f90 sourcefile~branchnodeconnections.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacdxsystem.f90 sourcefile~branchnodeconnections.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacevapcomponent.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~branchnodeconnections.f90->sourcefile~userdefinedcomponents.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacwatertoair.f90 sourcefile~branchnodeconnections.f90->sourcefile~branchinputmanager.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~branchnodeconnections.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~branchnodeconnections.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~branchnodeconnections.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataairloop.f90 DataAirLoop.f90 sourcefile~dataairloop.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~dataairloop.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataairloop.f90->sourcefile~emsmanager.f90 sourcefile~dataairloop.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataairloop.f90->sourcefile~mixedair.f90 sourcefile~dataairloop.f90->sourcefile~dxcoil.f90 sourcefile~dataairloop.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataairloop.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataairloop.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~dataairloop.f90->sourcefile~setpointmanager.f90 sourcefile~schedulemanager.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~schedulemanager.f90->sourcefile~hvacfancomponent.f90 sourcefile~schedulemanager.f90->sourcefile~datazoneequipment.f90 sourcefile~schedulemanager.f90->sourcefile~emsmanager.f90 sourcefile~schedulemanager.f90->sourcefile~hvacheatingcoils.f90 sourcefile~schedulemanager.f90->sourcefile~mixedair.f90 sourcefile~schedulemanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~schedulemanager.f90->sourcefile~dxcoil.f90 sourcefile~schedulemanager.f90->sourcefile~nodeinputmanager.f90 sourcefile~schedulemanager.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~schedulemanager.f90->sourcefile~heatrecovery.f90 sourcefile~schedulemanager.f90->sourcefile~outputprocessor.f90 sourcefile~schedulemanager.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~schedulemanager.f90->sourcefile~refrigeratedcase.f90 sourcefile~schedulemanager.f90->sourcefile~watermanager.f90 sourcefile~schedulemanager.f90->sourcefile~faultsmanager.f90 sourcefile~schedulemanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~schedulemanager.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~schedulemanager.f90->sourcefile~hvacdxsystem.f90 sourcefile~schedulemanager.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~schedulemanager.f90->sourcefile~hvacevapcomponent.f90 sourcefile~schedulemanager.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~schedulemanager.f90->sourcefile~setpointmanager.f90 sourcefile~schedulemanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~schedulemanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~schedulemanager.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~schedulemanager.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~hvacwatercoilcomponent.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~hvacwatercoilcomponent.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~hvacwatercoilcomponent.f90->sourcefile~mixedair.f90 sourcefile~hvacwatercoilcomponent.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvacwatercoilcomponent.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~dxcoil.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~dxcoil.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~dxcoil.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dxcoil.f90->sourcefile~heatrecovery.f90 sourcefile~dxcoil.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dxcoil.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~dxcoil.f90->sourcefile~hvacdxsystem.f90 sourcefile~dxcoil.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~general.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~general.f90->sourcefile~hvacfancomponent.f90 sourcefile~general.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~general.f90->sourcefile~datazoneequipment.f90 sourcefile~general.f90->sourcefile~plantutilities.f90 sourcefile~general.f90->sourcefile~emsmanager.f90 sourcefile~general.f90->sourcefile~hvacheatingcoils.f90 sourcefile~general.f90->sourcefile~reportsizingmanager.f90 sourcefile~general.f90->sourcefile~mixedair.f90 sourcefile~general.f90->sourcefile~dataenvironment.f90 sourcefile~general.f90->sourcefile~psychroutines.f90 sourcefile~general.f90->sourcefile~branchnodeconnections.f90 sourcefile~general.f90->sourcefile~schedulemanager.f90 sourcefile~general.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~general.f90->sourcefile~dxcoil.f90 sourcefile~general.f90->sourcefile~dataplant.f90 sourcefile~general.f90->sourcefile~nodeinputmanager.f90 sourcefile~general.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~general.f90->sourcefile~fluidproperties.f90 sourcefile~general.f90->sourcefile~curvemanager.f90 sourcefile~general.f90->sourcefile~heatrecovery.f90 sourcefile~general.f90->sourcefile~dataheatbalance.f90 sourcefile~general.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~general.f90->sourcefile~outputprocessor.f90 sourcefile~general.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~general.f90->sourcefile~refrigeratedcase.f90 sourcefile~general.f90->sourcefile~watermanager.f90 sourcefile~general.f90->sourcefile~hvacunitarysystem.f90 sourcefile~general.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~general.f90->sourcefile~hvacdxsystem.f90 sourcefile~general.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~general.f90->sourcefile~hvacevapcomponent.f90 sourcefile~general.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~general.f90->sourcefile~userdefinedcomponents.f90 sourcefile~general.f90->sourcefile~hvacwatertoair.f90 sourcefile~general.f90->sourcefile~setpointmanager.f90 sourcefile~general.f90->sourcefile~branchinputmanager.f90 sourcefile~general.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~general.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~general.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~general.f90->sourcefile~plantsolarcollectors.f90 sourcefile~general.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~general.f90->sourcefile~vectorutilities.f90 sourcefile~general.f90->sourcefile~standardratings.f90 sourcefile~dataplant.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~dataplant.f90->sourcefile~plantutilities.f90 sourcefile~dataplant.f90->sourcefile~dataairsystems.f90 sourcefile~dataplant.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataplant.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~dataplant.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataplant.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataplant.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~dataplant.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~dataplant.f90->sourcefile~userdefinedcomponents.f90 sourcefile~dataplant.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataplant.f90->sourcefile~setpointmanager.f90 sourcefile~dataplant.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataplant.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataplant.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataplant.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataplant.f90->sourcefile~standardratings.f90 sourcefile~dataprecisionglobals.f90 DataPrecisionGlobals.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datahvacglobals.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datazoneequipment.f90 sourcefile~dataprecisionglobals.f90->sourcefile~plantutilities.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datasizing.f90 sourcefile~dataprecisionglobals.f90->sourcefile~emsmanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datainterfaces.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datazonecontrols.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataprecisionglobals.f90->sourcefile~reportsizingmanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataloopnode.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataairsystems.f90 sourcefile~dataprecisionglobals.f90->sourcefile~mixedair.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataenvironment.f90 sourcefile~dataprecisionglobals.f90->sourcefile~psychroutines.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datazoneenergydemands.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataairloop.f90 sourcefile~dataprecisionglobals.f90->sourcefile~schedulemanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dxcoil.f90 sourcefile~dataprecisionglobals.f90->sourcefile~general.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataplant.f90 sourcefile~dataglobals.f90 DataGlobals.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataglobals.f90 sourcefile~dataprecisionglobals.f90->sourcefile~nodeinputmanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~dataprecisionglobals.f90->sourcefile~fluidproperties.f90 sourcefile~dataprecisionglobals.f90->sourcefile~inputprocessor.f90 sourcefile~dataprecisionglobals.f90->sourcefile~curvemanager.f90 sourcefile~outputreportpredefined.f90 OutputReportPredefined.f90 sourcefile~dataprecisionglobals.f90->sourcefile~outputreportpredefined.f90 sourcefile~datacontaminantbalance.f90 DataContaminantBalance.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datacontaminantbalance.f90 sourcefile~dataairflownetwork.f90 DataAirflowNetwork.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataairflownetwork.f90 sourcefile~databranchairloopplant.f90 DataBranchAirLoopPlant.f90 sourcefile~dataprecisionglobals.f90->sourcefile~databranchairloopplant.f90 sourcefile~dataipshortcuts.f90 DataIPShortCuts.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataipshortcuts.f90 sourcefile~datasystemvariables.f90 DataSystemVariables.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datasystemvariables.f90 sourcefile~datasurfaces.f90 DataSurfaces.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datasurfaces.f90 sourcefile~datavectortypes.f90 DataVectorTypes.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datavectortypes.f90 sourcefile~databsdfwindow.f90 DataBSDFWindow.f90 sourcefile~dataprecisionglobals.f90->sourcefile~databsdfwindow.f90 sourcefile~dataprecisionglobals.f90->sourcefile~heatrecovery.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataheatbalance.f90 sourcefile~datacomplexfenestration.f90 DataComplexFenestration.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datacomplexfenestration.f90 sourcefile~dataequivalentlayerwindow.f90 DataEquivalentLayerWindow.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataequivalentlayerwindow.f90 sourcefile~dataprecisionglobals.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~dataprecisionglobals.f90->sourcefile~outputprocessor.f90 sourcefile~dataprecisionglobals.f90->sourcefile~outairnodemanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataruntimelanguage.f90 sourcefile~dataprecisionglobals.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~dataroomair.f90 DataRoomAir.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataroomair.f90 sourcefile~dataprecisionglobals.f90->sourcefile~globalnames.f90 sourcefile~dataprecisionglobals.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataprecisionglobals.f90->sourcefile~watermanager.f90 sourcefile~datawater.f90 DataWater.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datawater.f90 sourcefile~dataheatbalfansys.f90 DataHeatBalFanSys.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataheatbalfansys.f90 sourcefile~dataprecisionglobals.f90->sourcefile~faultsmanager.f90 sourcefile~datadefineequip.f90 Datadefineequip.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datadefineequip.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataprecisionglobals.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataprecisionglobals.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacevapcomponent.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~dataprecisionglobals.f90->sourcefile~userdefinedcomponents.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataprecisionglobals.f90->sourcefile~setpointmanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~branchinputmanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataerrortracking.f90 DataErrorTracking.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataerrortracking.f90 sourcefile~dataprecisionglobals.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataprecisionglobals.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataprecisionglobals.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataphotovoltaics.f90 DataPhotovoltaics.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataphotovoltaics.f90 sourcefile~dataprecisionglobals.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~dataprecisionglobals.f90->sourcefile~vectorutilities.f90 sourcefile~dataheatbalsurface.f90 DataHeatBalSurface.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataheatbalsurface.f90 sourcefile~dataprecisionglobals.f90->sourcefile~standardratings.f90 sourcefile~dataglobals.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~dataglobals.f90->sourcefile~datahvacglobals.f90 sourcefile~dataglobals.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataglobals.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~dataglobals.f90->sourcefile~datazoneequipment.f90 sourcefile~dataglobals.f90->sourcefile~plantutilities.f90 sourcefile~dataglobals.f90->sourcefile~datasizing.f90 sourcefile~dataglobals.f90->sourcefile~emsmanager.f90 sourcefile~dataglobals.f90->sourcefile~datazonecontrols.f90 sourcefile~dataglobals.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataglobals.f90->sourcefile~reportsizingmanager.f90 sourcefile~dataglobals.f90->sourcefile~dataloopnode.f90 sourcefile~dataglobals.f90->sourcefile~dataairsystems.f90 sourcefile~dataglobals.f90->sourcefile~mixedair.f90 sourcefile~dataglobals.f90->sourcefile~dataenvironment.f90 sourcefile~dataglobals.f90->sourcefile~psychroutines.f90 sourcefile~dataglobals.f90->sourcefile~branchnodeconnections.f90 sourcefile~dataglobals.f90->sourcefile~dataairloop.f90 sourcefile~dataglobals.f90->sourcefile~schedulemanager.f90 sourcefile~dataglobals.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataglobals.f90->sourcefile~dxcoil.f90 sourcefile~dataglobals.f90->sourcefile~general.f90 sourcefile~dataglobals.f90->sourcefile~dataplant.f90 sourcefile~dataglobals.f90->sourcefile~nodeinputmanager.f90 sourcefile~dataglobals.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~dataglobals.f90->sourcefile~fluidproperties.f90 sourcefile~dataglobals.f90->sourcefile~inputprocessor.f90 sourcefile~dataglobals.f90->sourcefile~curvemanager.f90 sourcefile~dataglobals.f90->sourcefile~outputreportpredefined.f90 sourcefile~dataglobals.f90->sourcefile~datacontaminantbalance.f90 sourcefile~dataglobals.f90->sourcefile~dataairflownetwork.f90 sourcefile~dataglobals.f90->sourcefile~databranchairloopplant.f90 sourcefile~dataglobals.f90->sourcefile~dataipshortcuts.f90 sourcefile~dataglobals.f90->sourcefile~datasurfaces.f90 sourcefile~dataglobals.f90->sourcefile~databsdfwindow.f90 sourcefile~dataglobals.f90->sourcefile~heatrecovery.f90 sourcefile~dataglobals.f90->sourcefile~dataheatbalance.f90 sourcefile~dataglobals.f90->sourcefile~datacomplexfenestration.f90 sourcefile~dataglobals.f90->sourcefile~dataequivalentlayerwindow.f90 sourcefile~dataglobals.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~dataglobals.f90->sourcefile~outputprocessor.f90 sourcefile~dataglobals.f90->sourcefile~outairnodemanager.f90 sourcefile~dataglobals.f90->sourcefile~dataruntimelanguage.f90 sourcefile~sortandstringutilities.f90 SortAndStringUtilities.f90 sourcefile~dataglobals.f90->sourcefile~sortandstringutilities.f90 sourcefile~dataoutputs.f90 DataOutputs.f90 sourcefile~dataglobals.f90->sourcefile~dataoutputs.f90 sourcefile~dataglobals.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~dataglobalconstants.f90 DataGlobalConstants.f90 sourcefile~dataglobals.f90->sourcefile~dataglobalconstants.f90 sourcefile~dataglobals.f90->sourcefile~dataroomair.f90 sourcefile~dataglobals.f90->sourcefile~globalnames.f90 sourcefile~dataglobals.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataglobals.f90->sourcefile~watermanager.f90 sourcefile~dataglobals.f90->sourcefile~datawater.f90 sourcefile~dataglobals.f90->sourcefile~faultsmanager.f90 sourcefile~dataglobals.f90->sourcefile~datadefineequip.f90 sourcefile~dataglobals.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataglobals.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~dataglobals.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataglobals.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~dataglobals.f90->sourcefile~hvacevapcomponent.f90 sourcefile~dataglobals.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~dataglobals.f90->sourcefile~userdefinedcomponents.f90 sourcefile~dataglobals.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataglobals.f90->sourcefile~setpointmanager.f90 sourcefile~dataglobals.f90->sourcefile~branchinputmanager.f90 sourcefile~dataglobals.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataglobals.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataglobals.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataglobals.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataglobals.f90->sourcefile~dataphotovoltaics.f90 sourcefile~dataglobals.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~dataglobals.f90->sourcefile~vectorutilities.f90 sourcefile~databranchnodeconnections.f90 DataBranchNodeConnections.f90 sourcefile~dataglobals.f90->sourcefile~databranchnodeconnections.f90 sourcefile~dataglobals.f90->sourcefile~standardratings.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacfancomponent.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~nodeinputmanager.f90->sourcefile~datazoneequipment.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacheatingcoils.f90 sourcefile~nodeinputmanager.f90->sourcefile~mixedair.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~nodeinputmanager.f90->sourcefile~dxcoil.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~nodeinputmanager.f90->sourcefile~heatrecovery.f90 sourcefile~nodeinputmanager.f90->sourcefile~outairnodemanager.f90 sourcefile~nodeinputmanager.f90->sourcefile~refrigeratedcase.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~nodeinputmanager.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacdxsystem.f90 sourcefile~nodeinputmanager.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacevapcomponent.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~nodeinputmanager.f90->sourcefile~userdefinedcomponents.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacwatertoair.f90 sourcefile~nodeinputmanager.f90->sourcefile~setpointmanager.f90 sourcefile~nodeinputmanager.f90->sourcefile~branchinputmanager.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~nodeinputmanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~nodeinputmanager.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~nodeinputmanager.f90->sourcefile~plantsolarcollectors.f90 sourcefile~hvacsteamcoilcomponent.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~hvacsteamcoilcomponent.f90->sourcefile~mixedair.f90 sourcefile~hvacsteamcoilcomponent.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvacsteamcoilcomponent.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~fluidproperties.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~fluidproperties.f90->sourcefile~plantutilities.f90 sourcefile~fluidproperties.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~fluidproperties.f90->sourcefile~nodeinputmanager.f90 sourcefile~fluidproperties.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~fluidproperties.f90->sourcefile~refrigeratedcase.f90 sourcefile~fluidproperties.f90->sourcefile~hvacunitarysystem.f90 sourcefile~fluidproperties.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~fluidproperties.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~fluidproperties.f90->sourcefile~userdefinedcomponents.f90 sourcefile~fluidproperties.f90->sourcefile~hvacwatertoair.f90 sourcefile~fluidproperties.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~fluidproperties.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~fluidproperties.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~fluidproperties.f90->sourcefile~plantsolarcollectors.f90 sourcefile~fluidproperties.f90->sourcefile~standardratings.f90 sourcefile~inputprocessor.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~inputprocessor.f90->sourcefile~hvacfancomponent.f90 sourcefile~inputprocessor.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~inputprocessor.f90->sourcefile~datazoneequipment.f90 sourcefile~inputprocessor.f90->sourcefile~emsmanager.f90 sourcefile~inputprocessor.f90->sourcefile~hvacheatingcoils.f90 sourcefile~inputprocessor.f90->sourcefile~mixedair.f90 sourcefile~inputprocessor.f90->sourcefile~branchnodeconnections.f90 sourcefile~inputprocessor.f90->sourcefile~schedulemanager.f90 sourcefile~inputprocessor.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~inputprocessor.f90->sourcefile~dxcoil.f90 sourcefile~inputprocessor.f90->sourcefile~general.f90 sourcefile~inputprocessor.f90->sourcefile~dataplant.f90 sourcefile~inputprocessor.f90->sourcefile~nodeinputmanager.f90 sourcefile~inputprocessor.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~inputprocessor.f90->sourcefile~fluidproperties.f90 sourcefile~inputprocessor.f90->sourcefile~curvemanager.f90 sourcefile~inputprocessor.f90->sourcefile~heatrecovery.f90 sourcefile~inputprocessor.f90->sourcefile~dataheatbalance.f90 sourcefile~inputprocessor.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~inputprocessor.f90->sourcefile~outputprocessor.f90 sourcefile~inputprocessor.f90->sourcefile~outairnodemanager.f90 sourcefile~inputprocessor.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~inputprocessor.f90->sourcefile~dataglobalconstants.f90 sourcefile~inputprocessor.f90->sourcefile~globalnames.f90 sourcefile~inputprocessor.f90->sourcefile~refrigeratedcase.f90 sourcefile~inputprocessor.f90->sourcefile~watermanager.f90 sourcefile~inputprocessor.f90->sourcefile~faultsmanager.f90 sourcefile~inputprocessor.f90->sourcefile~hvacunitarysystem.f90 sourcefile~inputprocessor.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~inputprocessor.f90->sourcefile~hvacdxsystem.f90 sourcefile~inputprocessor.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~inputprocessor.f90->sourcefile~hvacevapcomponent.f90 sourcefile~inputprocessor.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~inputprocessor.f90->sourcefile~userdefinedcomponents.f90 sourcefile~inputprocessor.f90->sourcefile~hvacwatertoair.f90 sourcefile~inputprocessor.f90->sourcefile~setpointmanager.f90 sourcefile~inputprocessor.f90->sourcefile~branchinputmanager.f90 sourcefile~inputprocessor.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~inputprocessor.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~inputprocessor.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~inputprocessor.f90->sourcefile~plantsolarcollectors.f90 sourcefile~inputprocessor.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~curvemanager.f90->sourcefile~hvacfancomponent.f90 sourcefile~curvemanager.f90->sourcefile~hvacheatingcoils.f90 sourcefile~curvemanager.f90->sourcefile~mixedair.f90 sourcefile~curvemanager.f90->sourcefile~dxcoil.f90 sourcefile~curvemanager.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~curvemanager.f90->sourcefile~refrigeratedcase.f90 sourcefile~curvemanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~curvemanager.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~curvemanager.f90->sourcefile~hvacwatertoair.f90 sourcefile~curvemanager.f90->sourcefile~setpointmanager.f90 sourcefile~curvemanager.f90->sourcefile~branchinputmanager.f90 sourcefile~curvemanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~curvemanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~curvemanager.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~curvemanager.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~curvemanager.f90->sourcefile~standardratings.f90 sourcefile~outputreportpredefined.f90->sourcefile~hvacfancomponent.f90 sourcefile~outputreportpredefined.f90->sourcefile~hvacheatingcoils.f90 sourcefile~outputreportpredefined.f90->sourcefile~reportsizingmanager.f90 sourcefile~outputreportpredefined.f90->sourcefile~mixedair.f90 sourcefile~outputreportpredefined.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~outputreportpredefined.f90->sourcefile~dxcoil.f90 sourcefile~outputreportpredefined.f90->sourcefile~outputprocessor.f90 sourcefile~outputreportpredefined.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~outputreportpredefined.f90->sourcefile~hvacwatertoair.f90 sourcefile~outputreportpredefined.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~outputreportpredefined.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~outputreportpredefined.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~outputreportpredefined.f90->sourcefile~standardratings.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacfancomponent.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacheatingcoils.f90 sourcefile~datacontaminantbalance.f90->sourcefile~mixedair.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~datacontaminantbalance.f90->sourcefile~dxcoil.f90 sourcefile~datacontaminantbalance.f90->sourcefile~nodeinputmanager.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~datacontaminantbalance.f90->sourcefile~heatrecovery.f90 sourcefile~datacontaminantbalance.f90->sourcefile~outairnodemanager.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacevapcomponent.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacwatertoair.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataairflownetwork.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataairflownetwork.f90->sourcefile~hvacunitarysystem.f90 sourcefile~databranchairloopplant.f90->sourcefile~plantutilities.f90 sourcefile~databranchairloopplant.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~databranchairloopplant.f90->sourcefile~curvemanager.f90 sourcefile~databranchairloopplant.f90->sourcefile~branchinputmanager.f90 sourcefile~databranchairloopplant.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~databranchairloopplant.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~databranchairloopplant.f90->sourcefile~standardratings.f90 sourcefile~dataipshortcuts.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataipshortcuts.f90->sourcefile~mixedair.f90 sourcefile~dataipshortcuts.f90->sourcefile~schedulemanager.f90 sourcefile~dataipshortcuts.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataipshortcuts.f90->sourcefile~general.f90 sourcefile~dataipshortcuts.f90->sourcefile~inputprocessor.f90 sourcefile~dataipshortcuts.f90->sourcefile~curvemanager.f90 sourcefile~dataipshortcuts.f90->sourcefile~heatrecovery.f90 sourcefile~dataipshortcuts.f90->sourcefile~outputprocessor.f90 sourcefile~dataipshortcuts.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataipshortcuts.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~dataipshortcuts.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataipshortcuts.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~dataipshortcuts.f90->sourcefile~hvacevapcomponent.f90 sourcefile~dataipshortcuts.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~dataipshortcuts.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataipshortcuts.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataipshortcuts.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataipshortcuts.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~datasystemvariables.f90->sourcefile~schedulemanager.f90 sourcefile~datasystemvariables.f90->sourcefile~inputprocessor.f90 sourcefile~datasystemvariables.f90->sourcefile~curvemanager.f90 sourcefile~datasystemvariables.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~datasystemvariables.f90->sourcefile~outputprocessor.f90 sourcefile~datasystemvariables.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~datastringglobals.f90 DataStringGlobals.f90 sourcefile~datastringglobals.f90->sourcefile~schedulemanager.f90 sourcefile~datastringglobals.f90->sourcefile~general.f90 sourcefile~datastringglobals.f90->sourcefile~inputprocessor.f90 sourcefile~datastringglobals.f90->sourcefile~datasystemvariables.f90 sourcefile~datastringglobals.f90->sourcefile~outputprocessor.f90 sourcefile~datastringglobals.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~datasurfaces.f90->sourcefile~emsmanager.f90 sourcefile~datasurfaces.f90->sourcefile~general.f90 sourcefile~datasurfaces.f90->sourcefile~datacontaminantbalance.f90 sourcefile~datasurfaces.f90->sourcefile~dataheatbalance.f90 sourcefile~datasurfaces.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~datasurfaces.f90->sourcefile~watermanager.f90 sourcefile~datasurfaces.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~datasurfaces.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~datasurfaces.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~datasurfaces.f90->sourcefile~plantsolarcollectors.f90 sourcefile~datasurfaces.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~datasurfaces.f90->sourcefile~vectorutilities.f90 sourcefile~datavectortypes.f90->sourcefile~datasurfaces.f90 sourcefile~datavectortypes.f90->sourcefile~databsdfwindow.f90 sourcefile~datavectortypes.f90->sourcefile~dataheatbalance.f90 sourcefile~datavectortypes.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~datavectortypes.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~datavectortypes.f90->sourcefile~vectorutilities.f90 sourcefile~databsdfwindow.f90->sourcefile~datasurfaces.f90 sourcefile~databsdfwindow.f90->sourcefile~dataheatbalance.f90 sourcefile~heatrecovery.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~heatrecovery.f90->sourcefile~mixedair.f90 sourcefile~heatrecovery.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~dataheatbalance.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~dataheatbalance.f90->sourcefile~datazoneequipment.f90 sourcefile~dataheatbalance.f90->sourcefile~emsmanager.f90 sourcefile~dataheatbalance.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataheatbalance.f90->sourcefile~mixedair.f90 sourcefile~dataheatbalance.f90->sourcefile~dxcoil.f90 sourcefile~dataheatbalance.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~dataheatbalance.f90->sourcefile~outputprocessor.f90 sourcefile~dataheatbalance.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~dataheatbalance.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataheatbalance.f90->sourcefile~watermanager.f90 sourcefile~dataheatbalance.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataheatbalance.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~dataheatbalance.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataheatbalance.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~dataheatbalance.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~dataheatbalance.f90->sourcefile~userdefinedcomponents.f90 sourcefile~dataheatbalance.f90->sourcefile~setpointmanager.f90 sourcefile~dataheatbalance.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataheatbalance.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataheatbalance.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataheatbalance.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~datacomplexfenestration.f90->sourcefile~dataheatbalance.f90 sourcefile~dataequivalentlayerwindow.f90->sourcefile~dataheatbalance.f90 sourcefile~runtimelanguageprocessor.f90->sourcefile~emsmanager.f90 sourcefile~outputprocessor.f90->sourcefile~emsmanager.f90 sourcefile~outputprocessor.f90->sourcefile~nodeinputmanager.f90 sourcefile~outputprocessor.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~outairnodemanager.f90->sourcefile~emsmanager.f90 sourcefile~outairnodemanager.f90->sourcefile~mixedair.f90 sourcefile~outairnodemanager.f90->sourcefile~dxcoil.f90 sourcefile~outairnodemanager.f90->sourcefile~refrigeratedcase.f90 sourcefile~outairnodemanager.f90->sourcefile~desiccantdehumidifiers.f90 sourcefile~outairnodemanager.f90->sourcefile~hvacevapcomponent.f90 sourcefile~outairnodemanager.f90->sourcefile~setpointmanager.f90 sourcefile~outairnodemanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~outairnodemanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~outairnodemanager.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataruntimelanguage.f90->sourcefile~emsmanager.f90 sourcefile~dataruntimelanguage.f90->sourcefile~general.f90 sourcefile~dataruntimelanguage.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~dataruntimelanguage.f90->sourcefile~userdefinedcomponents.f90 sourcefile~sortandstringutilities.f90->sourcefile~inputprocessor.f90 sourcefile~sortandstringutilities.f90->sourcefile~outputprocessor.f90 sourcefile~dataoutputs.f90->sourcefile~inputprocessor.f90 sourcefile~dataoutputs.f90->sourcefile~outputprocessor.f90 sourcefile~sqlitefortranroutines.f90->sourcefile~reportsizingmanager.f90 sourcefile~sqlitefortranroutines.f90->sourcefile~outputprocessor.f90 sourcefile~dataglobalconstants.f90->sourcefile~outputprocessor.f90 sourcefile~dataglobalconstants.f90->sourcefile~hvacevapcomponent.f90 sourcefile~dataroomair.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~dataroomair.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~globalnames.f90->sourcefile~hvacheatingcoils.f90 sourcefile~globalnames.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~globalnames.f90->sourcefile~dxcoil.f90 sourcefile~globalnames.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~globalnames.f90->sourcefile~userdefinedcomponents.f90 sourcefile~globalnames.f90->sourcefile~hvacwatertoair.f90 sourcefile~globalnames.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~globalnames.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~globalnames.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~refrigeratedcase.f90->sourcefile~hvacheatingcoils.f90 sourcefile~refrigeratedcase.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~watermanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~watermanager.f90->sourcefile~dxcoil.f90 sourcefile~watermanager.f90->sourcefile~refrigeratedcase.f90 sourcefile~watermanager.f90->sourcefile~hvacevapcomponent.f90 sourcefile~watermanager.f90->sourcefile~userdefinedcomponents.f90 sourcefile~watermanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~watermanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~datawater.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~datawater.f90->sourcefile~dxcoil.f90 sourcefile~datawater.f90->sourcefile~refrigeratedcase.f90 sourcefile~datawater.f90->sourcefile~watermanager.f90 sourcefile~datawater.f90->sourcefile~hvacevapcomponent.f90 sourcefile~datawater.f90->sourcefile~userdefinedcomponents.f90 sourcefile~datawater.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~datawater.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataheatbalfansys.f90->sourcefile~mixedair.f90 sourcefile~dataheatbalfansys.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataheatbalfansys.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataheatbalfansys.f90->sourcefile~hvacevapcomponent.f90 sourcefile~dataheatbalfansys.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataheatbalfansys.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~faultsmanager.f90->sourcefile~mixedair.f90 sourcefile~datadefineequip.f90->sourcefile~mixedair.f90 sourcefile~hvacunitarysystem.f90->sourcefile~mixedair.f90 sourcefile~desiccantdehumidifiers.f90->sourcefile~mixedair.f90 sourcefile~hvacdxsystem.f90->sourcefile~mixedair.f90 sourcefile~hvacdxsystem.f90->sourcefile~hvacunitarysystem.f90 sourcefile~photovoltaicthermalcollectors.f90->sourcefile~mixedair.f90 sourcefile~hvacevapcomponent.f90->sourcefile~mixedair.f90 sourcefile~hvactranspiredcollector.f90->sourcefile~mixedair.f90 sourcefile~userdefinedcomponents.f90->sourcefile~mixedair.f90 sourcefile~hvacwatertoair.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datahvaccontrollers.f90 DataHVACControllers.f90 sourcefile~datahvaccontrollers.f90->sourcefile~hvacunitarysystem.f90 sourcefile~setpointmanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~setpointmanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~branchinputmanager.f90->sourcefile~dataplant.f90 sourcefile~branchinputmanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvacwatertoairmultispeedhp.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvacwatertoairmultispeedhp.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataerrortracking.f90->sourcefile~nodeinputmanager.f90 sourcefile~dataerrortracking.f90->sourcefile~branchinputmanager.f90 sourcefile~dataerrortracking.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~packagedthermalstoragecoil.f90->sourcefile~hvacdxsystem.f90 sourcefile~plantwaterthermaltank.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~plantsolarcollectors.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataphotovoltaics.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~heatbalanceconvectioncoeffs.f90->sourcefile~photovoltaicthermalcollectors.f90 sourcefile~heatbalanceconvectioncoeffs.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~vectorutilities.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~dataheatbalsurface.f90->sourcefile~hvactranspiredcollector.f90 sourcefile~dataheatbalsurface.f90->sourcefile~heatbalanceconvectioncoeffs.f90 sourcefile~databranchnodeconnections.f90->sourcefile~branchnodeconnections.f90 sourcefile~databranchnodeconnections.f90->sourcefile~dxcoil.f90 sourcefile~standardratings.f90->sourcefile~dxcoil.f90
Help

Files Dependent On This One

sourcefile~~hvacunitarybypassvav.f90~~AfferentGraph sourcefile~hvacunitarybypassvav.f90 HVACUnitaryBypassVAV.f90 sourcefile~simairservingzones.f90 SimAirServingZones.f90 sourcefile~hvacunitarybypassvav.f90->sourcefile~simairservingzones.f90 sourcefile~sizingmanager.f90 SizingManager.f90 sourcefile~simairservingzones.f90->sourcefile~sizingmanager.f90 sourcefile~hvacmanager.f90 HVACManager.f90 sourcefile~simairservingzones.f90->sourcefile~hvacmanager.f90 sourcefile~simulationmanager.f90 SimulationManager.f90 sourcefile~sizingmanager.f90->sourcefile~simulationmanager.f90 sourcefile~hvacmanager.f90->sourcefile~simulationmanager.f90 sourcefile~heatbalanceairmanager.f90 HeatBalanceAirManager.f90 sourcefile~hvacmanager.f90->sourcefile~heatbalanceairmanager.f90 sourcefile~energyplus.f90 EnergyPlus.f90 sourcefile~simulationmanager.f90->sourcefile~energyplus.f90 sourcefile~utilityroutines.f90 UtilityRoutines.f90 sourcefile~simulationmanager.f90->sourcefile~utilityroutines.f90 sourcefile~heatbalanceairmanager.f90->sourcefile~simulationmanager.f90 sourcefile~heatbalancesurfacemanager.f90 HeatBalanceSurfaceManager.f90 sourcefile~heatbalanceairmanager.f90->sourcefile~heatbalancesurfacemanager.f90 sourcefile~heatbalancesurfacemanager.f90->sourcefile~simulationmanager.f90 sourcefile~heatbalancemanager.f90 HeatBalanceManager.f90 sourcefile~heatbalancesurfacemanager.f90->sourcefile~heatbalancemanager.f90 sourcefile~heatbalancemanager.f90->sourcefile~sizingmanager.f90 sourcefile~heatbalancemanager.f90->sourcefile~simulationmanager.f90
Help


Source Code

MODULE HVACUnitaryBypassVAV

  ! Module containing the routines for modeling changeover-bypass VAV systems

  ! MODULE INFORMATION:
  !       AUTHOR         Richard Raustad
  !       DATE WRITTEN   July 2006
  !       MODIFIED       B. Nigusse, FSEC - January 2012 - Added steam and hot water heating coils
  !
  !       RE-ENGINEERED  na

  ! PURPOSE OF THIS MODULE:
  ! To encapsulate the data and algorithms needed to simulate changeover-bypass
  ! variable-air-volume (CBVAV) systems, which are considered "Air Loop Equipment" in EnergyPlus

  ! METHODOLOGY EMPLOYED:
  ! Units are modeled as a collection of components: outside air mixer,
  ! supply air fan, DX cooing coil, DX/gas/elec heating coil, and variable volume boxes.
  ! Control is accomplished by calculating the load in all zones to determine a mode of operation.
  ! The system will either cool, heat, or operate based on fan mode selection.

  ! The CBVAV system is initialized with no load (coils off) to determine the outlet temperature.
  ! A setpoint temperature is calculated on FirstHVACIteration = TRUE to force one VAV box fully open.
  ! Once the setpoint is calculated, the inlet node mass flow rate on FirstHVACIteration = FALSE is used to
  ! determine the bypass fraction. The simulation converges quickly on mass flow rate. If the zone
  ! temperatures float in the deadband, additional iterations are required to converge on mass flow rate.

  ! REFERENCES:
  ! "Temp & VVT Commercial Comfort Systems," Engineering Training Manual, Technical Development Program, Carrier Corp., 1995.
  ! "VariTrac Changeover Bypass VAV (Tracker System CB)," VAV-PRC003-EN, Trane Company, June 2004.
  ! "Ventilation for Changeover-Bypass VAV Systems," D. Stanke, ASHRAE Journal Vol. 46, No. 11, November 2004.
  !  Lawrence Berkeley Laboratory. Nov. 1993. DOE-2 Supplement Version 2.1E, Winklemann et.al.

  ! OTHER NOTES: None

  ! USE STATEMENTS:
  ! Use statements for data only modules
USE DataPrecisionGlobals
USE DataLoopNode
USE DataGlobals,     ONLY: BeginEnvrnFlag, MaxNameLength, SysSizingCalc, WarmupFlag, DoingSizing, SecInHour, ScheduleAlwaysOn
USE DataInterfaces,  ONLY: SetupOutputVariable, ShowWarningError, ShowFatalError, ShowSevereError, &
                           ShowContinueError, ShowContinueErrorTimeStamp, ShowRecurringWarningErrorAtEnd, &
                           ShowWarningMessage
USE DataHVACGlobals, ONLY: SmallMassFlow, SmallLoad, FanElecPower, DXElecCoolingPower, DXElecHeatingPower, &
                           OnOffFanPartLoadFraction, ElecHeatingCoilPower, SmallAirVolFlow, &
                           CycFanCycCoil, ContFanCycCoil, DrawThru, BlowThru, Coil_HeatingWater, Coil_HeatingSteam
USE DataEnvironment, ONLY: StdBaroPress, OutDryBulbTemp, OutBaroPress, StdRhoAir
USE DXCoils,         ONLY: DXCoilPartLoadRatio

IMPLICIT NONE         ! Enforce explicit typing of all variables

PRIVATE ! Everything private unless explicitly made public

  ! MODULE PARAMETER DEFINITIONS
! Compressor operation
INTEGER, PARAMETER :: On             = 1                ! Normal compressor operation
INTEGER, PARAMETER :: Off            = 0                ! Signal DXCoil that compressor should not run

! DX Coils supported in this module
INTEGER, PARAMETER :: CoilDX_CoolingSingleSpeed       = 1 ! Coil:DX:CoolingBypassFactorEmpirical
INTEGER, PARAMETER :: CoilDX_CoolingHXAssisted        = 2 ! Coil:DX:HeatExchangerAssisted
INTEGER, PARAMETER :: CoilDX_CoolingTwoStageWHumControl = 3 ! Coil:Cooling:DX:TwoStageWithHumidityControlMode
                                                 ! formerly (v3 and beyond) Coil:DX:MultiMode:CoolingEmpirical
INTEGER, PARAMETER :: CoilDX_HeatingEmpirical         = 4 ! Coil:DX:HeatingEmpirical
INTEGER, PARAMETER :: Coil_HeatingGas                 = 5 ! Coil:Gas:Heating
INTEGER, PARAMETER :: Coil_HeatingElectric            = 6 ! Coil:Electric:Heating

! Dehumidification control modes (DehumidControlMode) for Multimode units only
INTEGER, PARAMETER :: DehumidControl_None       = 0
INTEGER, PARAMETER :: DehumidControl_Multimode  = 1
INTEGER, PARAMETER :: DehumidControl_CoolReheat = 2

! Mode of operation
 INTEGER, PARAMETER :: CoolingMode         = 1            ! System operating mode is cooling
 INTEGER, PARAMETER :: HeatingMode         = 2            ! System operating mode is heating

! Priority control mode (prioritized thermostat signal)
INTEGER, PARAMETER :: CoolingPriority      = 1            ! Controls CBVAV system based on cooling priority
INTEGER, PARAMETER :: HeatingPriority      = 2            ! Controls CBVAV system based on heating priority
INTEGER, PARAMETER :: ZonePriority         = 3            ! Controls CBVAV system based on zone priority

! Airflow control for contant fan mode
INTEGER, PARAMETER :: UseCompressorOnFlow  = 1            ! Set compressor OFF air flow rate equal to compressor ON air flow rate
INTEGER, PARAMETER :: UseCompressorOffFlow = 2            ! Set compressor OFF air flow rate equal to user defined value

  ! DERIVED TYPE DEFINITIONS
TYPE CBVAVData
  ! input data
 CHARACTER(len=MaxNameLength) :: Name                     = ' ' ! Name of unit
 CHARACTER(len=MaxNameLength) :: UnitType                 = ' ' ! Type of unit
 CHARACTER(len=MaxNameLength) :: Sched                    = ' ' ! Availability schedule name
 INTEGER                      :: SchedPtr                 = 0   ! Index number to availability schedule
 REAL(r64)                    :: MaxCoolAirVolFlow        = 0.0d0 ! System air volumetric flow rate during cooling operation [m3/s]
 REAL(r64)                    :: MaxHeatAirVolFlow        = 0.0d0 ! System air volumetric flow rate during heating operation [m3/s]
 REAL(r64)                    :: MaxNoCoolHeatAirVolFlow  = 0.0d0 ! System air volumetric flow rate when no cooling or heating [m3/s]
 REAL(r64)                    :: MaxCoolAirMassFlow       = 0.0d0 ! System air mass flow rate during cooling operation [kg/s]
 REAL(r64)                    :: MaxHeatAirMassFlow       = 0.0d0 ! System air mass flow rate during heating operation [kg/s]
 REAL(r64)                    :: MaxNoCoolHeatAirMassFlow = 0.0d0 ! System air mass flow rate when no cooling or heating [kg/s]
 REAL(r64)                    :: CoolOutAirVolFlow        = 0.0d0 ! OA volumetric flow rate during cooling operation [m3/s]
 REAL(r64)                    :: HeatOutAirVolFlow        = 0.0d0 ! OA volumetric flow rate during heating operation [m3/s]
 REAL(r64)                    :: NoCoolHeatOutAirVolFlow  = 0.0d0 ! OA volumetric flow rate when no cooling or heating [m3/s]
 REAL(r64)                    :: CoolOutAirMassFlow       = 0.0d0 ! OA mass flow rate during cooling operation [kg/s]
 REAL(r64)                    :: HeatOutAirMassFlow       = 0.0d0 ! OA mass flow rate during heating operation [kg/s]
 REAL(r64)                    :: NoCoolHeatOutAirMassFlow = 0.0d0 ! OA mass flow rate when no cooling or heating [kg/s]
 INTEGER                      :: OutAirSchPtr             = 0   ! Index number to outside air multiplier schedule
 INTEGER                      :: AirInNode                = 0   ! Inlet air node number for CBVAV unit
 INTEGER                      :: AirOutNode               = 0   ! Outlet air node number for CBVAV unit
 INTEGER                      :: CondenserNodeNum         = 0   ! DX Coil condenser air inlet node number
 INTEGER                      :: MixerOutsideAirNode      = 0   ! Outside air node number for OA mixer
 INTEGER                      :: MixerMixedAirNode        = 0   ! Mixed air node number for OA mixer
 INTEGER                      :: MixerReliefAirNode       = 0   ! Relief air node number for OA mixer
 INTEGER                      :: MixerInletAirNode        = 0   ! Return air node number for OA mixer
 INTEGER                      :: SplitterOutletAirNode    = 0   ! Air node number for splitter (last component outlet node)
 CHARACTER(len=MaxNameLength) :: OAMixType                = ' ' ! type of outside air mixer
 CHARACTER(len=MaxNameLength) :: OAMixName                = ' ' ! Name of OA mixer
 INTEGER                      :: OAMixIndex               = 0   ! Index to OA mixer
 CHARACTER(len=MaxNameLength) :: FanName                  = ' ' ! Name of fan
 CHARACTER(len=MaxNameLength) :: FanType                  = ' ' ! Type of fan
 INTEGER                      :: FanPlace                 = 0   ! Fan placement is either blowthru (1) or drawthru (2)
 INTEGER                      :: FanType_Num              = 0   ! Fan type number (see DataHVACGlobals)
 INTEGER                      :: FanIndex                 = 0   ! Index number to fan
 INTEGER                      :: FanOpModeSchedPtr        = 0   ! Fan operating mode schedule pointer
 REAL(r64)                    :: FanVolFlow               = 0.0d0 ! Volumetric flow rate of system supply air fan [m3/s]
 REAL(r64)                    :: HeatingSpeedRatio        = 1.0d0 ! Fan speed ratio in heating mode
 REAL(r64)                    :: CoolingSpeedRatio        = 1.0d0 ! Fan speed ratio in cooling mode
 REAL(r64)                    :: NoHeatCoolSpeedRatio     = 1.0d0 ! Fan speed ratio when no cooling or heating
 LOGICAL                      :: CheckFanFlow          = .TRUE. ! Check fan volumetric flow versus system flow in init routine.
 CHARACTER(len=MaxNameLength) :: DXCoolCoilName           = ' ' ! Name of DX cooling coil
 CHARACTER(len=MaxNameLength) :: DXCoolCoilType           = ' ' ! Type of DX cooling coil,Coil:DX:CoolingBypassFactorEmpirical or
                                                                !               CoilSystem:Cooling:DX:HeatExchangerAssisted
 INTEGER                      :: DXCoolCoilType_Num       = 0   ! Numeric equivalent for DX cooling coil type
 INTEGER                      :: CoolCoilCompIndex        = 0   ! cooling coil component index number
 INTEGER                      :: DXCoolCoilIndexNum       = 0   ! actual DX cooling coil index number
 INTEGER                      :: DXHeatCoilIndexNum       = 0   ! actual DX heating coil index number
 CHARACTER(len=MaxNameLength) :: HeatCoilName             = ' ' ! Name of heating coil
 CHARACTER(len=MaxNameLength) :: HeatCoilType             = ' ' ! Type of heating coil,Coil:DX:HeatingEmpirical
                                                                ! Coil:Heater:Gas, Coil:Heater:Electric, Coil:Heater:Water
                                                                ! Coil:Heater:Steam
 INTEGER                      :: HeatCoilType_Num         = 0   ! Numeric equivalent for DX heating coil type
 INTEGER                      :: HeatCoilIndex            = 0   ! DX heating coil index number
 INTEGER                      :: OpMode                   =0    ! mode of operation; 1=cycling fan, cycling compressor
                                                                !                    2=continuous fan, cycling compresor
 INTEGER                      :: CoilControlNode          = 0   ! heating coil hot water or steam inlet node
 INTEGER                      :: CoilOutletNode      = 0   ! outlet node for hot water and steam coil
 INTEGER                      :: LoopNum                  = 0   ! plant loop index for water heating coil
 INTEGER                      :: LoopSide                 = 0   ! plant loop side  index for water heating coil
 INTEGER                      :: BranchNum                = 0   ! plant loop branch index for water heating coil
 INTEGER                      :: CompNum                  = 0   ! plant loop component index for water heating coil
 Integer                      :: HotWaterCoilMaxIterIndex  = 0  ! Index to recurring warning message
 Integer                      :: HotWaterCoilMaxIterIndex2 = 0  ! Index to recurring warning message
 REAL(r64)                    :: MaxHeatCoilFluidFlow     = 0.0d0 ! water or steam mass flow rate for heating coil [kg/s]
 REAL(r64)                    :: DesignHeatingCapacity    = 0.0d0 ! design heating capacity of the heating coil
 REAL(r64)                    :: DesignSuppHeatingCapacity= 0.0d0 ! Operating capacity of supplemental Heating Coil [W]
 REAL(r64)                    :: MinOATCompressor         = 0.0d0 ! Minimum OAT for compressor operation [C]
 REAL(r64)                    :: MinLATCooling            = 0.0d0 ! Minimum leaving air temp for compressor cooling operation [C]
 REAL(r64)                    :: MaxLATHeating            = 0.0d0 ! Maximum leaving air temp for heating operation [C]
 ! Report data
 REAL(r64)                    :: TotHeatEnergyRate        = 0.0d0 ! Total heating output [W]
 REAL(r64)                    :: TotHeatEnergy            = 0.0d0 ! Total heating output [J]
 REAL(r64)                    :: TotCoolEnergyRate        = 0.0d0 ! Total cooling output [W]
 REAL(r64)                    :: TotCoolEnergy            = 0.0d0 ! Total cooling output [J]
 REAL(r64)                    :: SensHeatEnergyRate       = 0.0d0 ! Sensible heating output [W]
 REAL(r64)                    :: SensHeatEnergy           = 0.0d0 ! Sensible heating output [J]
 REAL(r64)                    :: SensCoolEnergyRate       = 0.0d0 ! Sensible cooling output [W]
 REAL(r64)                    :: SensCoolEnergy           = 0.0d0 ! Sensible cooling output [J]
 REAL(r64)                    :: LatHeatEnergyRate        = 0.0d0 ! Latent heating output [W]
 REAL(r64)                    :: LatHeatEnergy            = 0.0d0 ! Latent heating output [J]
 REAL(r64)                    :: LatCoolEnergyRate        = 0.0d0 ! Latent cooling output [W]
 REAL(r64)                    :: LatCoolEnergy            = 0.0d0 ! Latent cooling output [J]
 REAL(r64)                    :: ElecPower                = 0.0d0 ! Electricity consumed [W]
 REAL(r64)                    :: ElecConsumption          = 0.0d0 ! Electricity consumed [J]
 REAL(r64)                    :: FanPartLoadRatio         = 0.0d0 ! Fan part-load ratio for time step
 REAL(r64)                    :: CompPartLoadRatio        = 0.0d0 ! Compressor part-load ratio for time step
 INTEGER                      :: LastMode                 = 0   ! Last mode of operation, coolingmode or heatingmode
 INTEGER                      :: AirFlowControl           = 0   ! Fan control mode, UseCompressorOnFlow or UseCompressorOffFlow
 REAL(r64)                    :: CompPartLoadFrac         = 0.0d0 ! Compressor part load ratio
 INTEGER                      :: AirLoopNumber            = 0   ! Air loop served by the CBVAV system
 INTEGER                      :: NumControlledZones       = 0
 INTEGER, DIMENSION(:), ALLOCATABLE :: ControlledZoneNum        ! Index to controlled zones
 INTEGER, DIMENSION(:), ALLOCATABLE :: ActualZoneNum            ! Actual zone number of controlled zone
 INTEGER, DIMENSION(:), ALLOCATABLE :: ActualZoneNodeNum        ! Actual zone node num of controlled zone
 INTEGER, DIMENSION(:), ALLOCATABLE :: CBVAVBoxOutletNode       ! Outlet node of CBVAV Box in controlled zone
 INTEGER, DIMENSION(:), ALLOCATABLE :: ZoneSequenceCoolingNum ! Index to cooling sequence/priority for this zone
 INTEGER, DIMENSION(:), ALLOCATABLE :: ZoneSequenceHeatingNum ! Index to heating sequence/priority for this zone

 INTEGER                      :: PriorityControl          = 0   ! Control mode - CoolingPriority, HeatingPriority, or ZonePriority
 INTEGER                      :: NumZonesCooled           = 0   ! Number of zones requesting cooling
 INTEGER                      :: NumZonesHeated           = 0   ! Number of zones requesting heating
 INTEGER                      :: PLRMaxIter               = 0   ! Counter for recurring warning message
 INTEGER                      :: PLRMaxIterIndex          = 0   ! Index to recurring warning message
 INTEGER                      :: DXCoilInletNode          = 0   ! Inlet node number of DX cooling coil
 INTEGER                      :: DXCoilOutletNode         = 0   ! Outlet node number of DX cooling coil
 INTEGER                      :: HeatingCoilInletNode     = 0   ! Inlet node of heating coil
 INTEGER                      :: HeatingCoilOutletNode    = 0   ! Outlet node of heating coil
 INTEGER                      :: FanInletNodeNum          = 0   ! fan inlet node number
 REAL(r64)                    :: OutletTempSetpoint       = 0.0d0 ! Oulet node temperature setpoint [C]
 REAL(r64)                    :: CoilTempSetpoint         = 0.0d0 ! Coil oulet node temperature setpoint (inc. fan heat) [C]
 INTEGER                      :: HeatCoolMode             = 0   ! System operating mode (0 = floating, 1 = cooling, 2 = heating)
 REAL(r64)                    :: BypassMassFlowRate       = 0.0d0 ! Bypass mass flow rate report variable [m3/s]
 INTEGER                      :: DehumidificationMode     = 0   ! Dehumidification mode (0=normal, 1=enhanced)
 INTEGER                      :: DehumidControlType       = 0   ! Dehumidification control type (currently only for multimode coil)
 LOGICAL                      :: HumRatMaxCheck         =.TRUE. ! Used in Init for warning messages
 INTEGER                      :: DXIterationExceeded      = 0   ! Counter for DX coil messages
 INTEGER                      :: DXIterationExceededIndex = 0   ! Counter for DX coil messages
 INTEGER                      :: DXIterationFailed        = 0   ! Counter for DX coil messages
 INTEGER                      :: DXIterationFailedIndex   = 0   ! Counter for DX coil messages
 INTEGER                      :: HXDXIterationExceeded    = 0   ! Counter for HX assisted DX coil messages
 INTEGER                      :: HXDXIterationExceededIndex= 0  ! Counter for HX assisted DX coil messages
 INTEGER                      :: HXDXIterationFailed      = 0   ! Counter for HX assisted DX coil messages
 INTEGER                      :: HXDXIterationFailedIndex = 0   ! Counter for HX assisted DX coil messages
 INTEGER                      :: MMDXIterationExceeded    = 0   ! Counter for multimode DX coil messages
 INTEGER                      :: MMDXIterationExceededIndex= 0  ! Counter for multimode DX coil messages
 INTEGER                      :: MMDXIterationFailed      = 0   ! Counter for multimode DX coil messages
 INTEGER                      :: MMDXIterationFailedIndex = 0   ! Counter for multimode DX coil messages
 INTEGER                      :: DMDXIterationExceeded    = 0   ! Counter for dehumidifying multimode DX coil messages
 INTEGER                      :: DMDXIterationExceededIndex= 0  ! Counter for dehumidifying multimode DX coil messages
 INTEGER                      :: DMDXIterationFailed      = 0   ! Counter for dehumidifying multimode DX coil messages
 INTEGER                      :: DMDXIterationFailedIndex = 0   ! Counter for dehumidifying multimode DX coil messages
 INTEGER                      :: CRDXIterationExceeded    = 0   ! Counter for cool reheat multimode DX coil messages
 INTEGER                      :: CRDXIterationExceededIndex= 0  ! Counter for cool reheat multimode DX coil messages
 INTEGER                      :: CRDXIterationFailed      = 0   ! Counter for cool reheat multimode DX coil messages
 INTEGER                      :: CRDXIterationFailedIndex = 0   ! Counter for cool reheat multimode DX coil messages
END TYPE CBVAVData

  ! MODULE VARIABLE DECLARATIONS:
TYPE (CBVAVData), ALLOCATABLE, DIMENSION(:) :: CBVAV

INTEGER      :: NumCBVAV               = 0     ! Number of CBVAV systems in input file
REAL(r64)    :: CompOnMassFlow         = 0.0d0   ! System air mass flow rate w/ compressor ON
REAL(r64)    :: OACompOnMassFlow       = 0.0d0   ! OA mass flow rate w/ compressor ON
REAL(r64)    :: CompOffMassFlow        = 0.0d0   ! System air mass flow rate w/ compressor OFF
REAL(r64)    :: OACompOffMassFlow      = 0.0d0   ! OA mass flow rate w/ compressor OFF
REAL(r64)    :: CompOnFlowRatio        = 0.0d0   ! fan flow ratio when coil on
REAL(r64)    :: CompOffFlowRatio       = 0.0d0   ! fan flow ratio when coil off
REAL(r64)    :: FanSpeedRatio          = 0.0d0   ! ratio of air flow ratio passed to fan object
REAL(r64)    :: ByPassDuctFlowFraction = 0.0d0   ! Fraction of unit mass flow that returns to inlet of CBVAV unit through bypass duct
REAL(r64)    :: PartLoadFrac           = 0.0d0   ! Compressor part-load fraction
REAL(r64)    :: SaveCompressorPLR      = 0.0d0   ! Holds DX compressor PLR from active DX coil
REAL(r64)    :: TempSteamIn            = 100.0d0 ! steam coil steam inlet temperature
LOGICAL, ALLOCATABLE, DIMENSION(:) :: CheckEquipName

  ! SUBROUTINE SPECIFICATIONS FOR MODULE

PUBLIC  SimUnitaryBypassVAV
PRIVATE SimCBVAV
PRIVATE GetCBVAV
PRIVATE InitCBVAV
PRIVATE SizeCBVAV
PRIVATE ControlCBVAVOutput
PRIVATE CalcCBVAV
PRIVATE SetAverageAirFlow
PRIVATE ReportCBVAV
PRIVATE CalcNonDXHeatingCoils

CONTAINS

SUBROUTINE SimUnitaryBypassVAV(CompName, FirstHVACIteration, AirLoopNum, CompIndex)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2006
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! Manages the simulation of a changeover-bypass VAV system. Called from SimAirServingZones.

          ! METHODOLOGY EMPLOYED:
          ! NA

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE General,        ONLY: TrimSigDigits
  USE InputProcessor, ONLY: FindItemInList

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  CHARACTER(len=*), INTENT    (IN) :: CompName            ! Name of the CBVAV system
  LOGICAL,          INTENT    (IN) :: FirstHVACIteration  ! TRUE if 1st HVAC simulation of system time step
  INTEGER,          INTENT    (IN) :: AirLoopNum          ! air loop index
  INTEGER,          INTENT (INOUT) :: CompIndex           ! Index to changeover-bypass VAV system

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER      :: CBVAVNum                ! Index of CBVAV system being simulated
  LOGICAL,SAVE :: GetInputFlag = .TRUE.  ! First time, input is "gotten"
  REAL(r64)    :: OnOffAirFlowRatio      ! Ratio of compressor ON airflow to average airflow over timestep
  REAL(r64)    :: QUnitOut               ! Sensible capacity delivered by this air loop system
  REAL(r64)    :: QZnLoad                ! Zone load required by all zones served by this air loop system
  LOGICAL      :: HXUnitOn          ! flag to enable heat exchanger

          ! FLOW

  ! First time SimUnitaryBypassVAV is called, get the input for all the CBVAVs
  IF (GetInputFlag) THEN
    CALL GetCBVAV
    GetInputFlag = .FALSE.
  END IF

  ! Find the correct changeover-bypass VAV unit
  IF (CompIndex == 0) THEN
    CBVAVNum = FindItemInList(CompName,CBVAV%Name,NumCBVAV)
    IF (CBVAVNum == 0) THEN
      CALL ShowFatalError('SimUnitaryBypassVAV: Unit not found='//TRIM(CompName))
    END IF
    CompIndex=CBVAVNum
  ELSE
    CBVAVNum=CompIndex
    IF (CBVAVNum > NumCBVAV .or. CBVAVNum < 1) THEN
      CALL ShowFatalError('SimUnitaryBypassVAV:  Invalid CompIndex passed='//  &
                          TRIM(TrimSigDigits(CBVAVNum))// &
                          ', Number of Units='//TRIM(TrimSigDigits(NumCBVAV))//  &
                          ', Entered Unit name='//TRIM(CompName))
    END IF
    IF (CheckEquipName(CBVAVNum)) THEN
      IF (CompName /= CBVAV(CBVAVNum)%Name) THEN
        CALL ShowFatalError('SimUnitaryBypassVAV: Invalid CompIndex passed='//  &
                            TRIM(TrimSigDigits(CBVAVNum))// &
                            ', Unit name='//TRIM(CompName)//', stored Unit Name for that index='//  &
                            TRIM(CBVAV(CBVAVNum)%Name))
      END IF
      CheckEquipName(CBVAVNum)=.false.
    ENDIF
  END IF

  OnOffAirFlowRatio = 0.0d0
  HXUnitOn = .TRUE.

  ! Initialize the changeover-bypass VAV system
  CALL InitCBVAV(CBVAVNum, FirstHVACIteration, AirLoopNum, QZnLoad, OnOffAirFlowRatio, HXUnitOn)

  ! Simulate the unit
  CALL SimCBVAV(CBVAVNum, FirstHVACIteration, QZnLoad, QUnitOut, OnOffAirFlowRatio, HXUnitOn)

  ! Report the result of the simulation
  CALL ReportCBVAV(CBVAVNum)

  RETURN
END SUBROUTINE SimUnitaryBypassVAV

SUBROUTINE SimCBVAV(CBVAVNum,FirstHVACIteration,QZnReq,QSensUnitOut,OnOffAirFlowRatio, HXUnitOn)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2006
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! Simulate a changeover-bypass VAV system.

          ! METHODOLOGY EMPLOYED:
          ! Calls ControlCBVAVOutput to obtain the desired unit output

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE Psychrometrics,  ONLY: PsyHFnTdbW

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  LOGICAL, INTENT (IN)    :: FirstHVACIteration ! TRUE if 1st HVAC simulation of system timestep
  INTEGER, INTENT (IN)    :: CBVAVNum            ! Index of the current CBVAV system being simulated
  REAL(r64),    INTENT (INOUT) :: QZnReq             ! Zone load for all zones served by this air loop system
  REAL(r64),    INTENT (OUT)   :: QSensUnitOut       ! Sensible delivered capacity [W]
  REAL(r64),    INTENT (INOUT) :: OnOffAirFlowRatio  ! Ratio of compressor ON airflow to AVERAGE airflow over timestep
  LOGICAL, INTENT (INOUT) :: HXUnitOn           ! flag to enable heat exchanger

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  LOGICAL :: UnitOn            ! TRUE if unit is on
  INTEGER :: OutletNode        ! CBVAV air outlet node
  INTEGER :: InletNode         ! CBVAV air inlet node
  REAL(r64)    :: QTotUnitOut       ! Total delivered capacity [W]
  REAL(r64)    :: AirMassFlow       ! Air mass flow rate [kg/s]
  REAL(r64)    :: HeatingPower      ! Power consumption of DX heating coil or electric heating coil [W]
  REAL(r64)    :: MinOutletHumRat   ! Minimum of inlet and outlet air humidity ratio [kg/kg]
  REAL(r64)    :: PartLoadFrac

  ! zero the fan and DX coils electricity consumption
  FanElecPower         = 0.0d0
  DXElecCoolingPower   = 0.0d0
  DXElecHeatingPower   = 0.0d0
  ElecHeatingCoilPower = 0.0d0
  SaveCompressorPLR    = 0.0d0

  ! initialize local variables
  UnitOn       = .TRUE.
  QSensUnitOut = 0.0d0
  OutletNode   = CBVAV(CBVAVNum)%AirOutNode
  InletNode    = CBVAV(CBVAVNum)%AirInNode
  AirMassFlow  = Node(InletNode)%MassFlowRate
  PartLoadFrac = 0.0d0

  ! set the on/off flags
  IF (CBVAV(CBVAVNum)%OPMode == CycFanCycCoil) THEN
    ! cycling unit only runs if there is a cooling or heating load.
     IF (CBVAV(CBVAVNum)%HeatCoolMode .EQ. 0 .OR. AirMassFlow < SmallMassFlow) THEN
       UnitOn = .FALSE.
     END IF
  ELSE IF  (CBVAV(CBVAVNum)%OPMode == ContFanCycCoil) THEN
    ! continuous unit: fan runs if scheduled on; coil runs only if there is a cooling or heating load
    IF (AirMassFlow.LT.SmallMassFlow) THEN
      UnitOn = .FALSE.
    END IF
  END IF

  OnOffFanPartLoadFraction = 1.0d0

  IF(UnitOn)THEN
    CALL ControlCBVAVOutput(CBVAVNum,FirstHVACIteration,QZnReq,PartLoadFrac,OnOffAirFlowRatio, HXUnitOn)
  ELSE
    CALL CalcCBVAV(CBVAVNum, FirstHVACIteration, PartLoadFrac, QSensUnitOut, QZnReq, OnOffAirFlowRatio, HXUnitOn)
  END IF

  ! calculate delivered capacity
  AirMassFlow = Node(OutletNode)%MassFlowRate

  QTotUnitOut = AirMassFlow * (Node(OutletNode)%Enthalpy - Node(InletNode)%Enthalpy)

  MinOutletHumRat = MIN(Node(InletNode)%HumRat,Node(OutletNode)%HumRat)

  QSensUnitOut = AirMassFlow * (PsyHFnTdbW(Node(OutletNode)%Temp,MinOutletHumRat) - &
                                PsyHFnTdbW(Node(InletNode)%Temp,MinOutletHumRat))

  ! report variables
  CBVAV(CBVAVNum)%CompPartLoadRatio = SaveCompressorPLR
  IF (UnitOn) THEN
    CBVAV(CBVAVNum)%FanPartLoadRatio = 1.0d0
  ELSE
    CBVAV(CBVAVNum)%FanPartLoadRatio = 0.0d0
  END IF

  CBVAV(CBVAVNum)%TotCoolEnergyRate  = ABS(MIN(0.0d0, QTotUnitOut))
  CBVAV(CBVAVNum)%TotHeatEnergyRate  = ABS(MAX(0.0d0, QTotUnitOut))
  CBVAV(CBVAVNum)%SensCoolEnergyRate = ABS(MIN(0.0d0, QSensUnitOut))
  CBVAV(CBVAVNum)%SensHeatEnergyRate = ABS(MAX(0.0d0, QSensUnitOut))
  CBVAV(CBVAVNum)%LatCoolEnergyRate  = ABS(MIN(0.0d0, (QTotUnitOut - QSensUnitOut)))
  CBVAV(CBVAVNum)%LatHeatEnergyRate  = ABS(MAX(0.0d0, (QTotUnitOut - QSensUnitOut)))

  IF(CBVAV(CBVAVNum)%HeatCoilType_Num .EQ. CoilDX_HeatingEmpirical)THEN
    HeatingPower = DXElecHeatingPower
  ELSEIF(CBVAV(CBVAVNum)%HeatCoilType_Num .EQ. Coil_HeatingElectric)THEN
    HeatingPower = ElecHeatingCoilPower
  ELSE
    HeatingPower = 0.0d0
  END IF

  CBVAV(CBVAVNum)%ElecPower = FanElecPower + DXElecCoolingPower + HeatingPower

  RETURN
END SUBROUTINE SimCBVAV

SUBROUTINE GetCBVAV

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2006
          !       MODIFIED       Bereket Nigusse, FSEC, April 2011: added OA Mixer object type
          !
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! Obtains input data for changeover-bypass VAV systems and stores it in CBVAV data structures

          ! METHODOLOGY EMPLOYED:
          ! Uses "Get" routines to read in data.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE Fans,                  ONLY: GetFanType, GetFanIndex, GetFanVolFlow, GetFanInletNode, GetFanOutletNode
  USE General,               ONLY: TrimSigDigits
  USE DXCoils,               ONLY: GetMinOATDXCoilCompressor => GetMinOATCompressor, &
                                   GetDXCoilInletNode=>GetCoilInletNode, GetDXCoilOutletNode=>GetCoilOutletNode, &
                                   GetDXCoilCondenserInletNode=>GetCoilCondenserInletNode, GetDXCoolCoilIndex=>GetDXCoilIndex
  USE MixedAir,              ONLY: GetOAMixerNodeNumbers
  USE DataSizing,            ONLY: AutoSize
  USE DataAirLoop,           ONLY: AirToZoneNodeInfo
  USE HeatingCoils,          ONLY: GetCoilInletNode, GetCoilOutletNode
  USE InputProcessor,        ONLY: GetNumObjectsFound, GetObjectItem, VerifyName, SameString
  USE DataAirSystems,        ONLY: PrimaryAirSystem
  USE ScheduleManager,       ONLY: CheckScheduleValueMinMax, GetScheduleIndex
  USE DataHVACGlobals,       ONLY: FanType_SimpleConstVolume, FanType_SimpleVAV, FanType_SimpleOnOff, FanType_ZoneExhaust, &
                                   NumPrimaryAirSys
  USE NodeInputManager,      ONLY: GetOnlySingleNode
  USE DataZoneEquipment,     ONLY: ZoneEquipConfig, ZoneEquipList,AirDistUnit_Num, DirectAir_Num
  USE BranchNodeConnections, ONLY: SetUpCompSets, TestCompSet
  USE DataZoneControls,      ONLY: TempControlledZone, NumTempControlledZones
  USE HVACHXAssistedCoolingCoil,  ONLY: GetHXDXCoilName, GetHXDXCoilInletNode=>GetCoilInletNode, &
                                        GetHXDXCoilOutletNode=>GetCoilOutletNode

  USE SteamCoils,            ONLY: GetSteamCoilAirInletNode=>GetCoilAirInletNode, GetSteamCoilIndex, &
                                   GetSteamCoilAirOutletNode=>GetCoilAirOutletNode, &
                                   GetSteamCoilSteamInletNode=>GetCoilSteamInletNode, &
                                   GetCoilMaxSteamFlowRate=>GetCoilMaxSteamFlowRate, GetTypeOfCoil, ZoneLoadControl
  USE WaterCoils,            ONLY: GetCoilWaterInletNode, GetCoilMaxWaterFlowRate, &
                                   GetWaterCoilInletNode=>GetCoilInletNode,GetWaterCoilOutletNode=>GetCoilOutletNode
  USE FluidProperties,       ONLY: GetSatDensityRefrig

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
          ! na

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER                        :: CBVAVIndex        ! Loop index
  INTEGER                        :: CBVAVNum          ! Current CBVAV number
  CHARACTER(len=MaxNameLength), &
                   DIMENSION(19) :: Alphas            ! Alpha items for object
  REAL(r64),       DIMENSION(11) :: Numbers           ! Numeric items for object
  CHARACTER(len=MaxNameLength)   :: CompSetFanInlet   ! Used in SetUpCompSets call
  CHARACTER(len=MaxNameLength)   :: CompSetCoolInlet  ! Used in SetUpCompSets call
  CHARACTER(len=MaxNameLength)   :: CompSetFanOutlet  ! Used in SetUpCompSets call
  CHARACTER(len=MaxNameLength)   :: CompSetCoolOutlet ! Used in SetUpCompSets call
  INTEGER                        :: NumAlphas         ! Number of Alphas for each GetObjectItem call
  INTEGER                        :: NumNumbers        ! Number of Numbers for each GetObjectItem call
  INTEGER                        :: IOStatus          ! Used in GetObjectItem
  LOGICAL                        :: ErrorsFound=.false.    ! Set to true if errors in input, fatal at end of routine
  LOGICAL                        :: DXErrorsFound=.false.  ! Set to true if errors in get coil input
!unused0509  LOGICAL                        :: FanErrorsFound=.false. ! Set to true if errors in get fan input
  LOGICAL                        :: IsNotOK           ! Flag to verify name
  LOGICAL                        :: IsBlank           ! Flag for blank name
  CHARACTER(len=MaxNameLength)   :: CurrentModuleObject    ! Object type for getting and error messages
  LOGICAL                        :: FanErrFlag = .FALSE. ! Error flag returned during CALL to GetFanType
  LOGICAL                        :: ErrFlag = .FALSE. ! Error flag returned during CALL to mining functions
  INTEGER                        :: FanIndex          ! Index to CBVAV's supply air fan
  REAL(r64)                      :: FanVolFlow        ! Maximum air volumetric flow rate of fan
  INTEGER                        :: AirLoopNum        ! Index to air loop served by this system
  INTEGER                        :: AirLoopZoneNum    ! Index to controlled zone
  INTEGER                        :: BranchNum         ! Index to branch containing this system
  INTEGER                        :: CompNum           ! Index to this system
  INTEGER, DIMENSION(4)          :: OANodeNums        ! Node numbers of OA mixer (OA, EA, RA, MA)
  CHARACTER(len=MaxNameLength)   :: HXDXCoolCoilName  ! Name of DX cooling coil used with Heat Exchanger Assisted Cooling Coil
  CHARACTER(len=MaxNameLength)   :: MixerInletNodeName     ! Name of mixer inlet node
  CHARACTER(len=MaxNameLength)   :: SplitterOutletNodeName ! Name of splitter outlet node
  INTEGER                        :: ControlNodeNum    ! Number of control zone when humidity control is specified
  INTEGER                        :: TstatZoneNum      ! Index to thermostats
  LOGICAL                        :: FoundTstatZone    ! TRUE if thermostat found in controlled zone
  LOGICAL                        :: OANodeErrFlag     ! TRUE if DX Coil condenser node is not found
  LOGICAL                        :: DXCoilErrFlag     ! used in warning messages
  CHARACTER(Len=MaxNameLength), DIMENSION(19) :: cAlphaFields   ! Alpha field names
  CHARACTER(Len=MaxNameLength), DIMENSION(11) :: cNumericFields ! Numeric field names
  LOGICAL,                      DIMENSION(19) :: lAlphaBlanks   ! Logical array, alpha field input BLANK = .true.
  LOGICAL,                      DIMENSION(11) :: lNumericBlanks ! Logical array, numeric field input BLANK = .true.
  INTEGER                        :: EquipNum = 0                ! local do loop index for equipment listed for a zone
  INTEGER                        :: HeatCoilInletNodeNum        ! Heating coil air inlet node number
  INTEGER                        :: HeatCoilOutletNodeNum       ! Heating coil air outlet node number
  INTEGER                        :: TempNodeNum                 ! HW coil water inlet node
  INTEGER                        :: SteamIndex                  ! steam coil index
  REAL(r64)                      :: SteamDensity                ! steam coil steam density

  Alphas = ' '
  Numbers = 0.0d0
  cAlphaFields=' '
  cNumericFields=' '
  lAlphaBlanks=.true.
  lNumericBlanks=.true.

  ! find the number of each type of CBVAV unit
  CurrentModuleObject = 'AirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypass'
  NumCBVAV = GetNumObjectsFound(CurrentModuleObject)

  ! allocate the data structures
  ALLOCATE(CBVAV(NumCBVAV))
  ALLOCATE(CheckEquipName(NumCBVAV))
  CheckEquipName=.true.

  ! loop over CBVAV units; get and load the input data
  DO CBVAVIndex = 1,NumCBVAV
    HeatCoilInletNodeNum = 0
    HeatCoilOutletNodeNum = 0
    CALL GetObjectItem(CurrentModuleObject,CBVAVIndex,Alphas,NumAlphas,Numbers,NumNumbers,IOStatus, &
                       NumBlank=lNumericBlanks,AlphaBlank=lAlphaBlanks, &
                       AlphaFieldNames=cAlphaFields,NumericFieldNames=cNumericFields)

    CBVAVNum = CBVAVIndex
    IsNotOK=.FALSE.
    IsBlank=.FALSE.
    CALL VerifyName(Alphas(1),CBVAV%Name,CBVAVNum-1,IsNotOK,IsBlank,TRIM(CurrentModuleObject)//' Name')
    IF (IsNotOK) THEN
      ErrorsFound=.true.
      IF (IsBlank) Alphas(1)='xxxxx'
    ENDIF
    CBVAV(CBVAVNum)%Name = Alphas(1)
    CBVAV(CBVAVNum)%UnitType = CurrentModuleObject
    CBVAV(CBVAVNum)%Sched = Alphas(2)
    IF (lAlphaBlanks(2)) THEN
      CBVAV(CBVAVNum)%SchedPtr = ScheduleAlwaysOn
    ELSE
      CBVAV(CBVAVNum)%SchedPtr = GetScheduleIndex(Alphas(2))  ! convert schedule name to pointer (index number)
      IF (CBVAV(CBVAVNum)%SchedPtr .EQ. 0) THEN
        CALL ShowSevereError(TRIM(CurrentModuleObject)//' '//TRIM(cAlphaFields(2))//' not found = '//TRIM(Alphas(2)))
        CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
        ErrorsFound=.TRUE.
      END IF
    ENDIF

    CBVAV(CBVAVNum)%MaxCoolAirVolFlow       = Numbers(1)
    IF (CBVAV(CBVAVNum)%MaxCoolAirVolFlow .LE. 0.0d0 .AND. CBVAV(CBVAVNum)%MaxCoolAirVolFlow .NE. AutoSize) THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cNumericFields(1))//' = ' &
                           //TRIM(TrimSigDigits(Numbers(1),7)))
      CALL ShowContinueError(TRIM(cNumericFields(1))//' must be greater than zero.')
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      ErrorsFound = .TRUE.
    END IF

    CBVAV(CBVAVNum)%MaxHeatAirVolFlow       = Numbers(2)
    IF (CBVAV(CBVAVNum)%MaxHeatAirVolFlow .LE. 0.0d0 .AND. CBVAV(CBVAVNum)%MaxHeatAirVolFlow .NE. AutoSize) THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cNumericFields(2))//' = ' &
                           //TRIM(TrimSigDigits(Numbers(2),7)))
      CALL ShowContinueError(TRIM(cNumericFields(2))//' must be greater than zero.')
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      ErrorsFound = .TRUE.
    END IF

    CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow = Numbers(3)
    IF (CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .LT. 0.0d0 .AND. CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .NE. AutoSize) THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cNumericFields(3))//' = ' &
                           //TRIM(TrimSigDigits(Numbers(3),7)))
      CALL ShowContinueError(TRIM(cNumericFields(3))//' must be greater than or equal to zero.')
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      ErrorsFound = .TRUE.
    END IF

    CBVAV(CBVAVNum)%CoolOutAirVolFlow       = Numbers(4)
    IF (CBVAV(CBVAVNum)%CoolOutAirVolFlow .LT. 0.0d0 .AND. CBVAV(CBVAVNum)%CoolOutAirVolFlow .NE. AutoSize) THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cNumericFields(4))//' = ' &
                         //TRIM(TrimSigDigits(Numbers(4),7)))
      CALL ShowContinueError(TRIM(cNumericFields(4))//' must be greater than or equal to zero.')
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      ErrorsFound = .TRUE.
    END IF

    CBVAV(CBVAVNum)%HeatOutAirVolFlow       = Numbers(5)
    IF (CBVAV(CBVAVNum)%HeatOutAirVolFlow .LT. 0.0d0 .AND. CBVAV(CBVAVNum)%HeatOutAirVolFlow .NE. AutoSize) THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cNumericFields(5))//' = ' &
                           //TRIM(TrimSigDigits(Numbers(5),7)))
      CALL ShowContinueError(TRIM(cNumericFields(5))//' must be greater than or equal to zero.')
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      ErrorsFound = .TRUE.
    END IF

    CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow = Numbers(6)
    IF (CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow .LT. 0.0d0 .AND. CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow .NE. AutoSize) THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cNumericFields(6))//' = ' &
                           //TRIM(TrimSigDigits(Numbers(6),7)))
      CALL ShowContinueError(TRIM(cNumericFields(6))//' must be greater than or equal to zero.')
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      ErrorsFound = .TRUE.
    END IF

    CBVAV(CBVAVNum)%OutAirSchPtr = GetScheduleIndex(Alphas(3))  ! convert schedule name to pointer (index number)
    IF (CBVAV(CBVAVNum)%OutAirSchPtr .NE. 0) THEN
      IF(.NOT. CheckScheduleValueMinMax(CBVAV(CBVAVNum)%OutAirSchPtr,'<', 0.0d0, '>', 1.0d0))THEN
        CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
        CALL ShowContinueError('The schedule values in '//TRIM(cAlphaFields(3))//' must be 0 to 1.')
        ErrorsFound=.TRUE.
      END IF
    END IF

    CBVAV(CBVAVNum)%AirInNode =  GetOnlySingleNode(Alphas(4),ErrorsFound,TRIM(CurrentModuleObject),Alphas(1), &
                                                   NodeType_Air,NodeConnectionType_Inlet,1,ObjectIsParent)

    MixerInletNodeName       = Alphas(5)
    SplitterOutletNodeName   = Alphas(6)

    CBVAV(CBVAVNum)%AirOutNode = GetOnlySingleNode(Alphas(7),ErrorsFound,TRIM(CurrentModuleObject),Alphas(1), &
                                                   NodeType_Air,NodeConnectionType_Outlet,1,ObjectIsParent)

    CBVAV(CBVAVNum)%MixerInletAirNode = GetOnlySingleNode(MixerInletNodeName,ErrorsFound,TRIM(CurrentModuleObject),Alphas(1), &
                                                          NodeType_Air,NodeConnectionType_Internal,1,ObjectIsParent)

    CBVAV(CBVAVNum)%MixerInletAirNode = &
               GetOnlySingleNode(MixerInletNodeName,ErrorsFound,TRIM(CurrentModuleObject),TRIM(Alphas(1)//'_Mixer'), &
                                 NodeType_Air,NodeConnectionType_Outlet,1,ObjectIsParent)

    CBVAV(CBVAVNum)%SplitterOutletAirNode = &
               GetOnlySingleNode(SplitterOutletNodeName,ErrorsFound,TRIM(CurrentModuleObject),Alphas(1), &
                                 NodeType_Air,NodeConnectionType_Internal,1,ObjectIsParent)

    CBVAV(CBVAVNum)%SplitterOutletAirNode = &
               GetOnlySingleNode(SplitterOutletNodeName,ErrorsFound,TRIM(CurrentModuleObject),TRIM(Alphas(1)//'_Splitter'), &
                                 NodeType_Air,NodeConnectionType_Inlet,1,ObjectIsParent)

    CBVAV(CBVAVNum)%OAMixType  = Alphas(8)
    CBVAV(CBVAVNum)%OAMixName  = Alphas(9)

    ErrFlag = .false.
    CALL ValidateComponent(CBVAV(CBVAVNum)%OAMixType,CBVAV(CBVAVNum)%OAMixName,ErrFlag,TRIM(CurrentModuleObject))
    IF (ErrFlag) THEN
       CALL ShowContinueError('specified in '//TRIM(CurrentModuleObject)//' = "'//TRIM(CBVAV(CBVAVNum)%Name)//'".')
       ErrorsFound = .TRUE.
    ELSE
       ! Get OA Mixer node numbers
       OANodeNums = GetOAMixerNodeNumbers(CBVAV(CBVAVNum)%OAMixName, ErrFlag)
       IF (ErrFlag) THEN
         CALL ShowContinueError('that was specified in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
         CALL ShowContinueError('..OutdoorAir:Mixer is required. Enter an OutdoorAir:Mixer object with this name.')
         ErrorsFound=.true.
       ELSE
         CBVAV(CBVAVNum)%MixerOutsideAirNode = OANodeNums(1)
         CBVAV(CBVAVNum)%MixerReliefAirNode  = OANodeNums(2)
         ! CBVAV(CBVAVNum)%MixerInletAirNode  = OANodeNums(3)
         CBVAV(CBVAVNum)%MixerMixedAirNode   = OANodeNums(4)
       ENDIF
    ENDIF

    IF(CBVAV(CBVAVNum)%MixerInletAirNode .NE. OANodeNums(3))THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
      CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(5))//' = '//TRIM(MixerInletNodeName)//'.')
      CALL ShowContinueError(TRIM(cAlphaFields(5))//' must be the same as'// &
                             ' the return air stream node specified in the OutdoorAir:Mixer object.')
      ErrorsFound = .TRUE.
    END IF

    IF(CBVAV(CBVAVNum)%MixerInletAirNode .EQ. CBVAV(CBVAVNum)%AirInNode)THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
      CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(5))//' = '//TRIM(MixerInletNodeName)//'.')
      CALL ShowContinueError(TRIM(cAlphaFields(5))//' must be different than the '//TRIM(cAlphaFields(4))//'.')
      ErrorsFound = .TRUE.
    END IF

    IF(CBVAV(CBVAVNum)%SplitterOutletAirNode .EQ. CBVAV(CBVAVNum)%AirOutNode)THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
      CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(6))//' = '//TRIM(SplitterOutletNodeName)//'.')
      CALL ShowContinueError(TRIM(cAlphaFields(6))//' must be different than the '//TRIM(cAlphaFields(7))//'.')
      ErrorsFound = .TRUE.
    END IF

    CBVAV(CBVAVNum)%FanType       = Alphas(10)
    CBVAV(CBVAVNum)%FanName       = Alphas(11)

    IF(SameString(Alphas(12),'BlowThrough'))THEN
      CBVAV(CBVAVNum)%FanPlace    = BlowThru
    ELSEIF(SameString(Alphas(12),'DrawThrough'))THEN
      CBVAV(CBVAVNum)%FanPlace    = DrawThru
    ELSE
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cAlphaFields(12))//' = '//TRIM(Alphas(12)))
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      ErrorsFound = .TRUE.
    END IF

    IF(CBVAV(CBVAVNum)%FanPlace == DrawThru)THEN
      IF(CBVAV(CBVAVNum)%SplitterOutletAirNode .NE. &
           GetFanOutletNode(CBVAV(CBVAVNum)%FanType,CBVAV(CBVAVNum)%FanName,ErrorsFound))THEN
        CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
        CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(6))//' = '//TRIM(SplitterOutletNodeName)//'.')
        CALL ShowContinueError(TRIM(cAlphaFields(6))//' must be the same as the fan outlet node specified in ' &
                               //TRIM(cAlphaFields(10))//' = '//TRIM(CBVAV(CBVAVNum)%FanType)//': '// &
                               TRIM(CBVAV(CBVAVNum)%FanName)//' when draw through '//TRIM(cAlphaFields(11))//' is selected.')
        ErrorsFound = .TRUE.
      END IF
    END IF

    CALL GetFanType(CBVAV(CBVAVNum)%FanName,CBVAV(CBVAVNum)%FanType_Num,FanErrFlag,CurrentModuleObject,CBVAV(CBVAVNum)%Name)
    IF(FanErrFlag)THEN
      CALL ShowContinueError(' illegal '//TRIM(cAlphaFields(11))//'="'//TRIM(Alphas(11))//'".')
      ErrorsFound = .TRUE.
      FanVolFlow = 9999.0d0
    ELSE
      CBVAV(CBVAVNum)%FanInletNodeNum=GetFanInletNode(CBVAV(CBVAVNum)%FanType,CBVAV(CBVAVNum)%FanName,FanErrFlag)
      CALL GetFanIndex(CBVAV(CBVAVNum)%FanName,FanIndex,FanErrFlag)
      CALL GetFanVolFlow(FanIndex,CBVAV(CBVAVNum)%FanVolFlow)
      FanVolFlow = CBVAV(CBVAVNum)%FanVolFlow
    END IF

    IF(FanVolFlow .NE. AutoSize)THEN
      IF(FanVolFlow .LT. CBVAV(CBVAVNum)%MaxCoolAirVolFlow .AND. CBVAV(CBVAVNum)%MaxCoolAirVolFlow .NE. AutoSize)THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' - air flow rate = '//TRIM(TrimSigDigits(FanVolFlow,7))// &
                              ' in '//TRIM(cAlphaFields(11))//' = '//TRIM(CBVAV(CBVAVNum)%FanName)//' is less than the '// &
                              TRIM(cNumericFields(1)))
        CALL ShowContinueError(' '//TRIM(cNumericFields(1))//' is reset to the'// &
                               ' fan flow rate and the simulation continues.')
        CALL ShowContinueError(' Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
        CBVAV(CBVAVNum)%MaxCoolAirVolFlow = FanVolFlow
      END IF
      IF(FanVolFlow .LT. CBVAV(CBVAVNum)%MaxHeatAirVolFlow .AND. CBVAV(CBVAVNum)%MaxHeatAirVolFlow .NE. AutoSize)THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' - air flow rate = '//TRIM(TrimSigDigits(FanVolFlow,7))// &
                              ' in '//TRIM(cAlphaFields(11))//' = '//TRIM(CBVAV(CBVAVNum)%FanName)//' is less than the '// &
                              TRIM(cNumericFields(2)))
        CALL ShowContinueError(' '//TRIM(cNumericFields(2))//' is reset to the'// &
                               ' fan flow rate and the simulation continues.')
        CALL ShowContinueError(' Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
        CBVAV(CBVAVNum)%MaxHeatAirVolFlow = FanVolFlow
      END IF
    END IF

!   only check that OA flow in cooling is >= SA flow in cooling when they are not autosized
    IF (CBVAV(CBVAVNum)%CoolOutAirVolFlow .GT. CBVAV(CBVAVNum)%MaxCoolAirVolFlow .AND. &
        CBVAV(CBVAVNum)%CoolOutAirVolFlow .NE. AutoSize .AND. CBVAV(CBVAVNum)%MaxCoolAirVolFlow .NE. AutoSize) THEN
      CALL ShowWarningError(TRIM(CurrentModuleObject)//': '//TRIM(cNumericFields(4))//' cannot be greater than '// &
                           TRIM(cNumericFields(1)))
      CALL ShowContinueError(' '//TRIM(cNumericFields(4))//' is reset to the'// &
                             ' fan flow rate and the simulation continues.')
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      CBVAV(CBVAVNum)%CoolOutAirVolFlow = FanVolFlow
    END IF

!   only check that SA flow in heating is >= OA flow in heating when they are not autosized
    IF (CBVAV(CBVAVNum)%HeatOutAirVolFlow .GT. CBVAV(CBVAVNum)%MaxHeatAirVolFlow .AND. &
        CBVAV(CBVAVNum)%HeatOutAirVolFlow .NE. AutoSize .AND. CBVAV(CBVAVNum)%MaxHeatAirVolFlow .NE. AutoSize) THEN
      CALL ShowWarningError(TRIM(CurrentModuleObject)//': '//TRIM(cNumericFields(5))//' cannot be greater than '// &
                           TRIM(cNumericFields(2)))
      CALL ShowContinueError(' '//TRIM(cNumericFields(5))//' is reset to the'// &
                             ' fan flow rate and the simulation continues.')
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      CBVAV(CBVAVNum)%HeatOutAirVolFlow = FanVolFlow
    END IF

    IF(SameString(Alphas(14),'Coil:Cooling:DX:SingleSpeed') .OR. &
       SameString(Alphas(14),'CoilSystem:Cooling:DX:HeatExchangerAssisted') .OR. &
       SameString(Alphas(14),'Coil:Cooling:DX:TwoStageWithHumidityControlMode')) THEN

      CBVAV(CBVAVNum)%DXCoolCoilType = Alphas(14)
      CBVAV(CBVAVNum)%DXCoolCoilName = Alphas(15)

      IF (SameString(Alphas(14),'Coil:Cooling:DX:SingleSpeed')) THEN
        CBVAV(CBVAVNum)%DXCoolCoilType_Num = CoilDX_CoolingSingleSpeed
        CBVAV(CBVAVNum)%DXCoilInletNode = &
                      GetDXCoilInletNode(CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,DXErrorsFound)
        CBVAV(CBVAVNum)%DXCoilOutletNode = &
                      GetDXCoilOutletNode(CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,DXErrorsFound)
        IF(DXErrorsFound)THEN
          CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
          CALL ShowContinueError('Coil:Cooling:DX:SingleSpeed "'//TRIM(CBVAV(CBVAVNum)%DXCoolCoilName)//'" not found.')
          ErrorsFound = .TRUE.
        ELSE

          DXCoilErrFlag=.false.
          CALL GetDXCoolCoilIndex(CBVAV(CBVAVNum)%DXCoolCoilName,CBVAV(CBVAVNum)%DXCoolCoilIndexNum, &
                              DXCoilErrFlag, CBVAV(CBVAVNum)%DXCoolCoilType)
          IF(DXCoilErrFlag)CALL ShowContinueError('...occurs in '//TRIM(CBVAV(CBVAVNum)%UnitType)// &
                                                  ' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')

!         Mine outdoor condenser node from DX coil object
          OANodeErrFlag = .FALSE.
          CBVAV(CBVAVNum)%CondenserNodeNum = &
            GetDXCoilCondenserInletNode(CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,OANodeErrFlag)
          IF(OANodeErrFlag)CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
        END IF
      ELSEIF (SameString(Alphas(14),'CoilSystem:Cooling:DX:HeatExchangerAssisted')) THEN
        CBVAV(CBVAVNum)%DXCoolCoilType_Num = CoilDX_CoolingHXAssisted
        HXDXCoolCoilName = GetHXDXCoilName(CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,DXErrorsFound)
        CBVAV(CBVAVNum)%DXCoilInletNode = &
                      GetHXDXCoilInletNode(CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,DXErrorsFound)
        CBVAV(CBVAVNum)%DXCoilOutletNode = &
                      GetHXDXCoilOutletNode(CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,DXErrorsFound)
        IF(DXErrorsFound)THEN
          CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
          CALL ShowContinueError('CoilSystem:Cooling:DX:HeatExchangerAssisted "'//TRIM(CBVAV(CBVAVNum)%DXCoolCoilName)//  &
             '" not found.')
          ErrorsFound = .TRUE.
        ELSE

          DXCoilErrFlag=.false.
          CALL GetDXCoolCoilIndex( &
               GetHXDXCoilName(CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,DXCoilErrFlag), &
               CBVAV(CBVAVNum)%DXCoolCoilIndexNum, DXCoilErrFlag, 'Coil:Cooling:DX:SingleSpeed')
          IF(DXCoilErrFlag)CALL ShowContinueError('...occurs in '//TRIM(CBVAV(CBVAVNum)%UnitType)// &
                                                  ' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')

!         Mine outdoor condenser node from DX coil through HXAssistedDXCoil object
          OANodeErrFlag = .FALSE.
          CBVAV(CBVAVNum)%CondenserNodeNum = &
            GetDXCoilCondenserInletNode('Coil:Cooling:DX:SingleSpeed', HXDXCoolCoilName, OANodeErrFlag)
          IF(OANodeErrFlag)CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
        END IF
      ELSEIF (SameString(Alphas(14),'Coil:Cooling:DX:TwoStageWithHumidityControlMode')) THEN
        CBVAV(CBVAVNum)%DXCoolCoilType_Num = CoilDX_CoolingTwoStageWHumControl
        CBVAV(CBVAVNum)%DXCoilInletNode = &
                      GetDXCoilInletNode(CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,DXErrorsFound)
        CBVAV(CBVAVNum)%DXCoilOutletNode = &
                      GetDXCoilOutletNode(CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,DXErrorsFound)
        IF(DXErrorsFound)THEN
          CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
          CALL ShowContinueError('Coil:Cooling:DX:TwoStageWithHumidityControlMode "'//TRIM(CBVAV(CBVAVNum)%DXCoolCoilName)// &
                                 '" not found.')
          ErrorsFound = .TRUE.
        ELSE

          DXCoilErrFlag=.false.
          CALL GetDXCoolCoilIndex(CBVAV(CBVAVNum)%DXCoolCoilName,CBVAV(CBVAVNum)%DXCoolCoilIndexNum, &
                              DXCoilErrFlag, CBVAV(CBVAVNum)%DXCoolCoilType)
          IF(DXCoilErrFlag)CALL ShowContinueError('...occurs in '//TRIM(CBVAV(CBVAVNum)%UnitType)// &
                                                  ' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')

!         Mine outdoor condenser node from multimode DX coil object
          OANodeErrFlag = .FALSE.
          CBVAV(CBVAVNum)%CondenserNodeNum = &
            GetDXCoilCondenserInletNode(CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,OANodeErrFlag)
          IF(OANodeErrFlag)CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
        END IF
      END IF

    ELSE
       CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
       CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(14))//' = '//TRIM(Alphas(14)))
       ErrorsFound = .TRUE.
    END IF

    CBVAV(CBVAVNum)%FanOpModeSchedPtr = GetScheduleIndex(Alphas(13))  ! convert schedule name to pointer (index number)
    IF (CBVAV(CBVAVNum)%FanOpModeSchedPtr .NE. 0) THEN
      IF(.NOT. CheckScheduleValueMinMax(CBVAV(CBVAVNum)%FanOpModeSchedPtr, '<', 0.0d0, '>', 1.0d0))THEN
        CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
        CALL ShowContinueError('The schedule values in '//TRIM(cAlphaFields(13))//' must be 0 to 1.')
        CALL ShowContinueError('A value of 0 represents cycling fan mode, any other value up to 1 represents constant fan mode.')
        ErrorsFound=.TRUE.
      END IF

!     Check supply air fan operating mode for cycling fan, if NOT cycling fan set AirFlowControl
      IF(.NOT. CheckScheduleValueMinMax(CBVAV(CBVAVNum)%FanOpModeSchedPtr,'>=',0.0d0,'<=',0.0d0))THEN !Objexx Range is 0 to 0?
!       set air flow control mode,
!       UseCompressorOnFlow  = operate at last cooling or heating air flow requested when compressor is off
!       UseCompressorOffFlow = operate at value specified by user (no input for this object type, UseCompONFlow)
!       AirFlowControl only valid if fan opmode = ContFanCycCoil
        IF (CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .EQ. 0.0d0) THEN
            CBVAV(CBVAVNum)%AirFlowControl = UseCompressorOnFlow
        ELSE
          CBVAV(CBVAVNum)%AirFlowControl = UseCompressorOffFlow
        END IF
      END IF

    ELSE
      IF(.NOT. lAlphaBlanks(13))THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
        CALL ShowContinueError(TRIM(cAlphaFields(13))//' = '//TRIM(Alphas(13))// &
                               ' not found. Supply air fan operating mode set to constant operation and simulation continues.')
      END IF
      CBVAV(CBVAVNum)%OpMode = ContFanCycCoil
      IF (CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .EQ. 0.0d0) THEN
          CBVAV(CBVAVNum)%AirFlowControl = UseCompressorOnFlow
      ELSE
        CBVAV(CBVAVNum)%AirFlowControl = UseCompressorOffFlow
      END IF
    END IF

!   Check FanVolFlow, must be >= CBVAV flow
    IF(FanVolFlow .NE. AutoSize)THEN
      IF(FanVolFlow .LT. CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .AND. CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .NE. AutoSize &
         .AND. CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .NE. 0.0d0)THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' - air flow rate = '//TRIM(TrimSigDigits(FanVolFlow,7))// &
                              ' in '//TRIM(cAlphaFields(11))//' = '//TRIM(CBVAV(CBVAVNum)%FanName)//' is less than '// &
                              TRIM(cNumericFields(3)))
        CALL ShowContinueError(' '//TRIM(cNumericFields(3))//' is reset to the'// &
                               ' fan flow rate and the simulation continues.')
        CALL ShowContinueError(' Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
        CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow = FanVolFlow
      END IF
    END IF
!   only check that OA flow when compressor is OFF is >= SA flow when compressor is OFF when both are not autosized and
!   that MaxNoCoolHeatAirVolFlow is /= 0 (trigger to use compressor ON flow, see AirFlowControl variable initialization above)
    IF (CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow .GT. CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .AND. &
        CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow .NE. AutoSize .AND. CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .NE. AutoSize .AND. &
        CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .NE. 0.0d0) THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//': '//TRIM(cNumericFields(6))//' cannot be greater than '//  &
                             TRIM(cNumericFields(3)))
        CALL ShowContinueError(' '//TRIM(cNumericFields(6))//' is reset to'// &
                               ' the fan flow rate and the simulation continues.')
        CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
        CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow = FanVolFlow
    END IF

    IF(SameString(Alphas(16),'Coil:Heating:DX:SingleSpeed') .OR. &
       SameString(Alphas(16),'Coil:Heating:Gas') .OR. &
       SameString(Alphas(16),'Coil:Heating:Electric').OR. &
       SameString(Alphas(16),'Coil:Heating:Water').OR. &
       SameString(Alphas(16),'Coil:Heating:Steam')) THEN
       CBVAV(CBVAVNum)%HeatCoilType   = Alphas(16)
       CBVAV(CBVAVNum)%HeatCoilName   = Alphas(17)

       IF (SameString(Alphas(16),'Coil:Heating:DX:SingleSpeed')) THEN
         CBVAV(CBVAVNum)%HeatCoilType_Num = CoilDX_HeatingEmpirical
         CBVAV(CBVAVNum)%MinOATCompressor        = &
           GetMinOATDXCoilCompressor(CBVAV(CBVAVNum)%HeatCoilType,CBVAV(CBVAVNum)%HeatCoilName,ErrorsFound)
         CBVAV(CBVAVNum)%HeatingCoilInletNode = &
                       GetDXCoilInletNode(CBVAV(CBVAVNum)%HeatCoilType,CBVAV(CBVAVNum)%HeatCoilName,ErrorsFound)
         CBVAV(CBVAVNum)%HeatingCoilOutletNode = &
                       GetDXCoilOutletNode(CBVAV(CBVAVNum)%HeatCoilType,CBVAV(CBVAVNum)%HeatCoilName,ErrorsFound)
         CALL GetDXCoolCoilIndex(CBVAV(CBVAVNum)%HeatCoilName,CBVAV(CBVAVNum)%DXHeatCoilIndexNum, &
                                 DXCoilErrFlag, CBVAV(CBVAVNum)%HeatCoilType)
         IF(DXCoilErrFlag)CALL ShowContinueError('...occurs in '//TRIM(CBVAV(CBVAVNum)%UnitType)// &
                                                 ' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')

       ELSEIF (SameString(Alphas(16),'Coil:Heating:Gas')) THEN
         CBVAV(CBVAVNum)%HeatCoilType_Num = Coil_HeatingGas
         CBVAV(CBVAVNum)%MinOATCompressor        = -999.9d0
         CBVAV(CBVAVNum)%HeatingCoilInletNode = &
                       GetCoilInletNode(CBVAV(CBVAVNum)%HeatCoilType,CBVAV(CBVAVNum)%HeatCoilName,ErrorsFound)
         CBVAV(CBVAVNum)%HeatingCoilOutletNode = &
                       GetCoilOutletNode(CBVAV(CBVAVNum)%HeatCoilType,CBVAV(CBVAVNum)%HeatCoilName,ErrorsFound)
       ELSEIF (SameString(Alphas(16),'Coil:Heating:Electric')) THEN
         CBVAV(CBVAVNum)%HeatCoilType_Num = Coil_HeatingElectric
         CBVAV(CBVAVNum)%MinOATCompressor        = -999.9d0
         CBVAV(CBVAVNum)%HeatingCoilInletNode = &
                       GetCoilInletNode(CBVAV(CBVAVNum)%HeatCoilType,CBVAV(CBVAVNum)%HeatCoilName,ErrorsFound)
         CBVAV(CBVAVNum)%HeatingCoilOutletNode = &
                       GetCoilOutletNode(CBVAV(CBVAVNum)%HeatCoilType,CBVAV(CBVAVNum)%HeatCoilName,ErrorsFound)
       ELSEIF (SameString(Alphas(16),'Coil:Heating:Water')) THEN
         CBVAV(CBVAVNum)%HeatCoilType_Num = Coil_HeatingWater
         ErrFlag = .FALSE.
         CBVAV(CBVAVNum)%CoilControlNode = GetCoilWaterInletNode('Coil:Heating:Water',  &
                                                 CBVAV(CBVAVNum)%HeatCoilName,ErrFlag)
         CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                                CBVAV(CBVAVNum)%HeatCoilName,ErrFlag)
         HeatCoilInletNodeNum = GetWaterCoilInletNode('Coil:Heating:Water', &
                                CBVAV(CBVAVNum)%HeatCoilName,ErrFlag)
         CBVAV(CBVAVNum)%HeatingCoilInletNode = HeatCoilInletNodeNum
         HeatCoilOutletNodeNum = GetWaterCoilOutletNode('Coil:Heating:Water', &
                                 CBVAV(CBVAVNum)%HeatCoilName,ErrFlag)
         CBVAV(CBVAVNum)%HeatingCoilOutletNode = HeatCoilOutletNodeNum
         IF(ErrFlag)THEN
           CALL ShowContinueError('...occurs in '//TRIM(CBVAV(CBVAVNum)%UnitType)// &
                                             ' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')
           ErrorsFound = .TRUE.
         END IF
       ELSEIF (SameString(Alphas(16),'COIL:HEATING:STEAM')) THEN
         CBVAV(CBVAVNum)%HeatCoilType_Num = Coil_HeatingSteam
         ErrFlag = .FALSE.
         CBVAV(CBVAVNum)%HeatCoilIndex      = GetSTeamCoilIndex('COIL:HEATING:STEAM',CBVAV(CBVAVNum)%HeatCoilName,ErrFlag)

         HeatCoilInletNodeNum = GetSteamCoilAirInletNode(CBVAV(CBVAVNum)%HeatCoilIndex, &
                                                CBVAV(CBVAVNum)%HeatCoilName,ErrFlag)
         CBVAV(CBVAVNum)%HeatingCoilInletNode  =  HeatCoilInletNodeNum
         CBVAV(CBVAVNum)%CoilControlNode = GetSteamCoilSteamInletNode(CBVAV(CBVAVNum)%HeatCoilIndex, &
                                                CBVAV(CBVAVNum)%HeatCoilName, ErrFlag)
         CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow = GetCoilMaxSteamFlowRate(CBVAV(CBVAVNum)%HeatCoilIndex,ErrFlag)
         SteamIndex = 0 ! Function GetSatDensityRefrig will look up steam index if 0 is passed
         SteamDensity=GetSatDensityRefrig("STEAM",TempSteamIn,1.0d0,SteamIndex,'GetUnitaryHeatCool:VAVChangeoverBypass')
         IF(CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow .GT. 0.0d0)THEN
           CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow = &
                              GetCoilMaxSteamFlowRate(CBVAV(CBVAVNum)%HeatCoilIndex,ErrFlag) * SteamDensity
         END IF
         HeatCoilOutletNodeNum = GetSteamCoilAirOutletNode(CBVAV(CBVAVNum)%HeatCoilIndex,CBVAV(CBVAVNum)%HeatCoilName,ErrFlag)
         CBVAV(CBVAVNum)%HeatingCoilOutletNode = HeatCoilOutletNodeNum
         IF(ErrFlag)THEN
           CALL ShowContinueError('...occurs in '//TRIM(CBVAV(CBVAVNum)%UnitType)// &
                                             ' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')
           ErrorsFound = .TRUE.
         END IF
       END IF
    ELSE
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cAlphaFields(16))//' = '//TRIM(Alphas(16)))
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      ErrorsFound = .TRUE.
    END IF

    IF(CBVAV(CBVAVNum)%DXCoilOutletNode .NE. CBVAV(CBVAVNum)%HeatingCoilInletNode)THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal coil placement. Cooling coil must be upstream of heating coil.')
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      ErrorsFound = .TRUE.
    END IF

    IF(CBVAV(CBVAVNum)%FanPlace == BlowThru) THEN
      IF(CBVAV(CBVAVNum)%SplitterOutletAirNode .NE. CBVAV(CBVAVNum)%HeatingCoilOutletNode)THEN
        CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
        CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(6))//' = '//TRIM(SplitterOutletNodeName)//'.')
        CALL ShowContinueError(TRIM(cAlphaFields(6))//' must be the same as the outlet node specified'// &
                            ' in the heating coil object = '//TRIM(CBVAV(CBVAVNum)%HeatCoilType)//': '// &
                            TRIM(CBVAV(CBVAVNum)%HeatCoilName)//' when blow through '//TRIM(cAlphaFields(12))//' is selected.')
        ErrorsFound = .TRUE.
      END IF
      IF(CBVAV(CBVAVNum)%MixerMixedAirNode .NE. CBVAV(CBVAVNum)%FanInletNodeNum)THEN
        CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
        CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(11))//'. The fan inlet node name must be the same as the mixed'// &
                               ' air node specified in the '//TRIM(cAlphaFields(9))//' = '//TRIM(CBVAV(CBVAVNum)%OAMixName)// &
                               ' when blow through '//TRIM(cAlphaFields(12))//' is selected.')
        ErrorsFound = .TRUE.
      END IF
    END IF

    IF(CBVAV(CBVAVNum)%FanPlace == DrawThru) THEN
      IF(CBVAV(CBVAVNum)%MixerMixedAirNode .NE. CBVAV(CBVAVNum)%DXCoilInletNode)THEN
        CALL ShowSevereError(TRIM(CurrentModuleObject)//': '//TRIM(CBVAV(CBVAVNum)%Name))
        CALL ShowContinueError('Illegal cooling coil placement. The cooling coil inlet node name must be the same as the mixed' &
                               //' air node specified in the '//TRIM(cAlphaFields(9))//' = '//TRIM(CBVAV(CBVAVNum)%OAMixName) &
                               //' when draw through '//TRIM(cAlphaFields(12))//' is selected.')
        ErrorsFound = .TRUE.
      END IF
    END IF

    IF(SameString(Alphas(18),'CoolingPriority'))THEN
      CBVAV(CBVAVNum)%PriorityControl    = CoolingPriority
    ELSEIF(SameString(Alphas(18),'HeatingPriority'))THEN
      CBVAV(CBVAVNum)%PriorityControl    = HeatingPriority
    ELSEIF(SameString(Alphas(18),'ZonePriority'))THEN
      CBVAV(CBVAVNum)%PriorityControl    = ZonePriority
    ELSE
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cAlphaFields(18))//' = '//TRIM(Alphas(18)))
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      CALL ShowContinueError('Valid choices are CoolingPriority, HeatingPriority, or ZonePriority.')
      ErrorsFound = .TRUE.
    END IF

    IF(Numbers(7) .GT. 0.0d0)THEN
      CBVAV(CBVAVNum)%MinLATCooling = Numbers(7)
    ELSE
      CBVAV(CBVAVNum)%MinLATCooling = 10.0d0
    END IF

    IF(Numbers(8) .GT. 0.0d0)THEN
      CBVAV(CBVAVNum)%MaxLATHeating = Numbers(8)
    ELSE
      CBVAV(CBVAVNum)%MaxLATHeating = 50.0d0
    END IF

    IF (CBVAV(CBVAVNum)%MinLATCooling .GT. CBVAV(CBVAVNum)%MaxLATHeating) THEN
      CALL ShowWarningError(TRIM(CurrentModuleObject)//': illegal leaving air temperature specified.')
      CALL ShowContinueError('Resetting '//TRIM(cNumericFields(7))//' equal to '// &
                             TRIM(cNumericFields(8))//' and the simulation continues.')
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      CBVAV(CBVAVNum)%MinLATCooling = CBVAV(CBVAVNum)%MaxLATHeating
    END IF

    ! Dehumidification control mode
    IF (SameString(Alphas(19),'None')) THEN
      CBVAV(CBVAVNum)%DehumidControlType=DehumidControl_None
    ELSEIF (SameString(Alphas(19),' ')) THEN
      CBVAV(CBVAVNum)%DehumidControlType=DehumidControl_None
    ELSEIF (SameString(Alphas(19),'Multimode')) THEN
      IF (CBVAV(CBVAVNum)%DXCoolCoilType_Num == CoilDX_CoolingTwoStageWHumControl) THEN
          CBVAV(CBVAVNum)%DehumidControlType=DehumidControl_Multimode
      ELSE
        CALL ShowWarningError('Invalid '//TRIM(cAlphaFields(19))//' = '//TRIM(Alphas(19)))
        CALL ShowContinueError('In '//TRIM(CurrentModuleObject)//' "'//TRIM(CBVAV(CBVAVNum)%Name)//'".')
        CALL ShowContinueError('Valid only with '//TRIM(cAlphaFields(14))//' = Coil:Cooling:DX:TwoStageWithHumidityControlMode.')
        CALL ShowContinueError('Setting '//TRIM(cAlphaFields(19))//' to "None" and the simulation continues.')
        CBVAV(CBVAVNum)%DehumidControlType=DehumidControl_None
      END IF
    ELSEIF (SameString(Alphas(19),'CoolReheat')) THEN
      IF (CBVAV(CBVAVNum)%DXCoolCoilType_Num == CoilDX_CoolingTwoStageWHumControl) THEN
          CBVAV(CBVAVNum)%DehumidControlType=DehumidControl_CoolReheat
      ELSE
        CALL ShowWarningError('Invalid '//TRIM(cAlphaFields(19))//' = '//TRIM(Alphas(19)))
        CALL ShowContinueError('In '//TRIM(CurrentModuleObject)//' "'//TRIM(CBVAV(CBVAVNum)%Name)//'".')
        CALL ShowContinueError('Valid only with '//TRIM(cAlphaFields(14))//' = Coil:Cooling:DX:TwoStageWithHumidityControlMode.')
        CALL ShowContinueError('Setting '//TRIM(cAlphaFields(19))//' to "None" and the simulation continues.')
        CBVAV(CBVAVNum)%DehumidControlType=DehumidControl_None
      END IF
    ELSE
      CALL ShowSevereError('Invalid '//TRIM(cAlphaFields(19))//' ='//TRIM(Alphas(19)))
      CALL ShowContinueError('In '//TRIM(CurrentModuleObject)//' "'//TRIM(CBVAV(CBVAVNum)%Name)//'".')
    END IF

    IF (CBVAV(CBVAVNum)%DXCoolCoilType_Num .GT. 0)THEN
      ControlNodeNum = GetOnlySingleNode(Alphas(7),ErrorsFound,TRIM(CurrentModuleObject),Alphas(1), &
                                         NodeType_Air,NodeConnectionType_Sensor,1,ObjectIsParent)
    END IF

!   Initialize last mode of compressor operation
    CBVAV(CBVAVNum)%LastMode = HeatingMode

    IF(CBVAV(CBVAVNum)%FanType_Num .NE. FanType_SimpleOnOff .AND. CBVAV(CBVAVNum)%FanType_Num .NE. FanType_SimpleConstVolume)THEN
      CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cAlphaFields(10))//' in fan object = '// &
                            TRIM(CBVAV(CBVAVNum)%FanName))
      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
      CALL ShowContinueError(' The fan object type must be Fan:OnOff or Fan:ConstantVolume.')
      ErrorsFound = .TRUE.
    ELSE IF(CBVAV(CBVAVNum)%FanType_Num == FanType_SimpleOnOff .OR. CBVAV(CBVAVNum)%FanType_Num == FanType_SimpleConstVolume)THEN
      IF(CBVAV(CBVAVNum)%FanType_Num.EQ.FanType_SimpleOnOff .AND. &
           .NOT. SameString(CBVAV(CBVAVNum)%FanType,'Fan:OnOff'))THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' has '//TRIM(cAlphaFields(10))//' = '// &
                              TRIM(CBVAV(CBVAVNum)%FanType)//' which is inconsistent with the fan object.')
        CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
        CALL ShowContinueError(' The fan object ('//TRIM(CBVAV(CBVAVNum)%FanName)// &
                               ') is actually a valid fan type and the simulation continues.')
        CALL ShowContinueError(' Node connections errors may result due to the inconsistent fan type.')
      END IF
      IF(CBVAV(CBVAVNum)%FanType_Num.EQ.FanType_SimpleConstVolume .AND. &
        .NOT. SameString(CBVAV(CBVAVNum)%FanType,'Fan:ConstantVolume'))THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' has '//TRIM(cAlphaFields(10))//' = '// &
                              TRIM(CBVAV(CBVAVNum)%FanType)//' which is inconsistent with fan object.')
        CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(CBVAV(CBVAVNum)%Name))
        CALL ShowContinueError(' The fan object ('//TRIM(CBVAV(CBVAVNum)%FanName)// &
                               ') is actually a valid fan type and the simulation continues.')
        CALL ShowContinueError(' Node connections errors may result due to the inconsistent fan type.')
      END IF
    END IF

    ! Add fan to component sets array
    IF (CBVAV(CBVAVNum)%FanPlace == BlowThru) THEN
      CompSetFanInlet   = NodeID(CBVAV(CBVAVNum)%MixerMixedAirNode)
      CompSetFanOutlet  = NodeID(CBVAV(CBVAVNum)%DXCoilInletNode)
    ELSE
      CompSetFanInlet   = NodeID(CBVAV(CBVAVNum)%HeatingCoilOutletNode)
      CompSetFanOutlet  = SplitterOutletNodeName
    END IF
    CompSetCoolInlet  = NodeID(CBVAV(CBVAVNum)%DXCoilInletNode)
    CompSetCoolOutlet = NodeID(CBVAV(CBVAVNum)%DXCoilOutletNode)

    ! Add fan to component sets array
    CALL SetUpCompSets(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name, &
                       CBVAV(CBVAVNum)%FanType,CBVAV(CBVAVNum)%FanName,CompSetFanInlet,CompSetFanOutlet)

    ! Add cooling coil to component sets array
    CALL SetUpCompSets(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name, &
                       CBVAV(CBVAVNum)%DXCoolCoilType,CBVAV(CBVAVNum)%DXCoolCoilName,CompSetCoolInlet,CompSetCoolOutlet)

    ! Add heating coil to component sets array
    CALL SetUpCompSets(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name, &
                       CBVAV(CBVAVNum)%HeatCoilType,CBVAV(CBVAVNum)%HeatCoilName,NodeID(CBVAV(CBVAVNum)%HeatingCoilInletNode), &
                       NodeID(CBVAV(CBVAVNum)%HeatingCoilOutletNode))

    ! Set up component set for OA mixer - use OA node and Mixed air node
    CALL SetUpCompSets(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name, &
                       CBVAV(CBVAVNum)%OAMixType,CBVAV(CBVAVNum)%OAMixName,NodeID(CBVAV(CBVAVNum)%MixerOutsideAirNode), &
                       NodeID(CBVAV(CBVAVNum)%MixerMixedAirNode))

    CALL TestCompSet(CBVAV(CBVAVNum)%UnitType,CBVAV(CBVAVNum)%Name,NodeID(CBVAV(CBVAVNum)%AirInNode), &
                     NodeID(CBVAV(CBVAVNum)%AirOutNode),'Air Nodes')

!   Find air loop associated with CBVAV system
    DO AirLoopNum = 1, NumPrimaryAirSys
      DO BranchNum = 1, PrimaryAirSystem(AirLoopNum)%NumBranches
         DO CompNum = 1, PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%TotalComponents
           IF(.NOT. SameString(PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%Name, &
                   CBVAV(CBVAVNum)%Name) .OR. &
                  .NOT. SameString(PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%TypeOf, &
                   CBVAV(CBVAVNum)%UnitType))CYCLE
                   CBVAV(CBVAVNum)%AirLoopNumber = AirLoopNum
!         Should EXIT here or do other checking?
              EXIT
         END DO
      END DO
    END DO

    IF(CBVAV(CBVAVNum)%AirLoopNumber .GT. 0)THEN
      CBVAV(CBVAVNum)%NumControlledZones = AirToZoneNodeInfo(CBVAV(CBVAVNum)%AirLoopNumber)%NumZonesCooled
      ALLOCATE (CBVAV(CBVAVNum)%ControlledZoneNum(CBVAV(CBVAVNum)%NumControlledZones))
      ALLOCATE (CBVAV(CBVAVNum)%ActualZoneNum(CBVAV(CBVAVNum)%NumControlledZones))
      ALLOCATE (CBVAV(CBVAVNum)%ActualZoneNodeNum(CBVAV(CBVAVNum)%NumControlledZones))
      ALLOCATE (CBVAV(CBVAVNum)%CBVAVBoxOutletNode(CBVAV(CBVAVNum)%NumControlledZones))
      ALLOCATE (CBVAV(CBVAVNum)%ZoneSequenceCoolingNum(CBVAV(CBVAVNum)%NumControlledZones))
      ALLOCATE (CBVAV(CBVAVNum)%ZoneSequenceHeatingNum(CBVAV(CBVAVNum)%NumControlledZones))

      CBVAV(CBVAVNum)%ControlledZoneNum = 0
      CBVAV(CBVAVNum)%ActualZoneNum     = 0
      DO AirLoopZoneNum = 1, AirToZoneNodeInfo(CBVAV(CBVAVNum)%AirLoopNumber)%NumZonesCooled
        CBVAV(CBVAVNum)%ControlledZoneNum(AirLoopZoneNum) = &
                                    AirToZoneNodeInfo(CBVAV(CBVAVNum)%AirLoopNumber)%CoolCtrlZoneNums(AirLoopZoneNum)
        IF(CBVAV(CBVAVNum)%ControlledZoneNum(AirLoopZoneNum) .GT. 0)THEN
          CBVAV(CBVAVNum)%ActualZoneNodeNum(AirLoopZoneNum) = &
                         ZoneEquipConfig(CBVAV(CBVAVNum)%ControlledZoneNum(AirLoopZoneNum))%ZoneNode
          CBVAV(CBVAVNum)%ActualZoneNum(AirLoopZoneNum) = &
                         ZoneEquipConfig(CBVAV(CBVAVNum)%ControlledZoneNum(AirLoopZoneNum))%ActualZoneNum
          CBVAV(CBVAVNum)%CBVAVBoxOutletNode(AirLoopZoneNum) = &
                         AirToZoneNodeInfo(CBVAV(CBVAVNum)%AirLoopNumber)%CoolZoneInletNodes(AirLoopZoneNum)
          ! check for thermostat in controlled zone
          FoundTstatZone = .FALSE.
          DO TstatZoneNum = 1, NumTempControlledZones
            IF(TempControlledZone(TstatZoneNum)%ActualZoneNum .NE. CBVAV(CBVAVNum)%ControlledZoneNum(AirLoopZoneNum))CYCLE
            FoundTstatZone = .TRUE.
          END DO
          IF(.NOT. FoundTstatZone)THEN
            CALL ShowWarningError(TRIM(CurrentModuleObject)//' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')
            CALL ShowContinueError('Thermostat not found in zone = ' &
                                   //TRIM(ZoneEquipConfig(CBVAV(CBVAVNum)%ControlledZoneNum(AirLoopZoneNum))%ZoneName)// &
                                   ' and the simulation continues.')
            CALL ShowContinueError('This zone will not be controlled to a temperature setpoint.')
          END IF
        ELSE
         CALL ShowSevereError('Controlled Zone node not found.')
         ErrorsFound = .TRUE.
        END IF
        IF (ZoneEquipConfig(CBVAV(CBVAVNum)%ActualZoneNum(AirLoopZoneNum))%EquipListIndex > 0) THEN
          DO EquipNum = 1, ZoneEquipList(ZoneEquipConfig(CBVAV(CBVAVNum)%ActualZoneNum(AirLoopZoneNum))%EquipListIndex) &
                                %NumOfEquipTypes
            IF ((ZoneEquipList(ZoneEquipConfig(CBVAV(CBVAVNum)%ActualZoneNum(AirLoopZoneNum))%EquipListIndex)% &
                                EquipType_Num(EquipNum) == AirDistUnit_Num) &
                .OR. (ZoneEquipList(ZoneEquipConfig(CBVAV(CBVAVNum)%ActualZoneNum(AirLoopZoneNum))%EquipListIndex)% &
                                EquipType_Num(EquipNum) == DirectAir_Num) ) THEN
              CBVAV(CBVAVNum)%ZoneSequenceCoolingNum(AirLoopZoneNum) = &
                         ZoneEquipList(ZoneEquipConfig(CBVAV(CBVAVNum)%ActualZoneNum(AirLoopZoneNum))% &
                                EquipListIndex)%CoolingPriority(EquipNum)
              CBVAV(CBVAVNum)%ZoneSequenceHeatingNum(AirLoopZoneNum) = &
                         ZoneEquipList(ZoneEquipConfig(CBVAV(CBVAVNum)%ActualZoneNum(AirLoopZoneNum))% &
                                EquipListIndex)%HeatingPriority(EquipNum)
            ENDIF
          ENDDO
        ENDIF

      END DO
    ELSE
    END IF

  END DO ! CBVAVIndex = 1,NumCBVAV

  IF (ErrorsFound) THEN
    CALL ShowFatalError('GetCBVAV: Errors found in getting '//TRIM(CurrentModuleObject)//' input.')
    CALL ShowContinueError('... Preceding condition causes termination.')
  END IF

  DO CBVAVNum=1,NumCBVAV
    ! Setup Report variables for the Fan Coils
    CALL SetupOutputVariable('Unitary System Total Heating Rate [W]',CBVAV(CBVAVNum)%TotHeatEnergyRate,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Total Heating Energy [J]',CBVAV(CBVAVNum)%TotHeatEnergy,&
                             'System','Sum',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Total Cooling Rate [W]',CBVAV(CBVAVNum)%TotCoolEnergyRate,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Total Cooling Energy [J]',CBVAV(CBVAVNum)%TotCoolEnergy,&
                             'System','Sum',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Sensible Heating Rate [W]',CBVAV(CBVAVNum)%SensHeatEnergyRate,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Sensible Heating Energy [J]',CBVAV(CBVAVNum)%SensHeatEnergy,&
                             'System','Sum',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Sensible Cooling Rate [W]',CBVAV(CBVAVNum)%SensCoolEnergyRate,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Sensible Cooling Energy [J]',CBVAV(CBVAVNum)%SensCoolEnergy,&
                             'System','Sum',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Latent Heating Rate [W]',CBVAV(CBVAVNum)%LatHeatEnergyRate,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Latent Heating Energy [J]',CBVAV(CBVAVNum)%LatHeatEnergy,&
                             'System','Sum',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Latent Cooling Rate [W]',CBVAV(CBVAVNum)%LatCoolEnergyRate,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Latent Cooling Energy [J]',CBVAV(CBVAVNum)%LatCoolEnergy,&
                             'System','Sum',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Electric Power [W]',CBVAV(CBVAVNum)%ElecPower,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Electric Energy [J]',CBVAV(CBVAVNum)%ElecConsumption,&
                             'System','Sum',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Fan Part Load Ratio []',CBVAV(CBVAVNum)%FanPartLoadRatio,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Compressor Part Load Ratio []',CBVAV(CBVAVNum)%CompPartLoadRatio,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Bypass Air Mass Flow Rate [kg/s]',CBVAV(CBVAVNum)%BypassMassFlowRate,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
    CALL SetupOutputVariable('Unitary System Air Outlet Setpoint Temperature [C]',CBVAV(CBVAVNum)%OutletTempSetpoint,&
                             'System','Average',CBVAV(CBVAVNum)%Name)
  END DO

  RETURN
END SUBROUTINE GetCBVAV

SUBROUTINE InitCBVAV(CBVAVNum, FirstHVACIteration, AirLoopNum, QZnReq, OnOffAirFlowRatio, HXUnitOn)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2006
          !       MODIFIED       B. Griffith, May 2009, EMS setpoint check
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine is for initializations of the changeover-bypass VAV system components.

          ! METHODOLOGY EMPLOYED:
          ! Uses the status flags to trigger initializations. The CBVAV system is simulated with no load (coils off) to
          ! determine the outlet temperature. A setpoint temperature is calculated on FirstHVACIteration = TRUE.
          ! Once the setpoint is calculated, the inlet mass flow rate on FirstHVACIteration = FALSE is used to
          ! determine the bypass fraction. The simulation converges quickly on mass flow rate. If the zone
          ! temperatures float in the deadband, additional iterations are required to converge on mass flow rate.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE Fans,                 ONLY: GetFanIndex, GetFanVolFlow
  USE General,              ONLY: TrimSigDigits
  USE DataSizing,           ONLY: AutoSize
  USE Psychrometrics,       ONLY: PsyRhoAirFnPbTdbW
  USE ScheduleManager,      ONLY: GetCurrentScheduleValue
  USE DataAirLoop,          ONLY: AirLoopControlInfo
  USE DataGlobals,          ONLY: AnyEnergyManagementSystemInModel
  USE EMSManager,           ONLY: CheckIfNodeSetpointManagedByEMS, iHumidityRatioMaxSetpoint
  USE SteamCoils,           ONLY: SimulateSteamCoilComponents, GetCoilMaxSteamFlowRate=>GetCoilMaxSteamFlowRate, &
                                  GetSteamCoilCapacity=>GetCoilCapacity
  USE WaterCoils,           ONLY: GetCoilMaxWaterFlowRate, SimulateWaterCoilComponents
  USE DataPlant,            ONLY: TypeOf_CoilSteamAirHeating, ScanPlantLoopsForObject, TypeOf_CoilWaterSimpleHeating, &
                                  PlantLoop
  USE FluidProperties,      ONLY: GetDensityGlycol, GetSatDensityRefrig
  USE PlantUtilities,       ONLY: SetComponentFlowRate, InitComponentNodes
  USE DataGlobals,          ONLY: InitConvTemp, AnyPlantInModel

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT (IN)    :: CBVAVNum            ! Index of the current CBVAV unit being simulated
  LOGICAL, INTENT (IN)    :: FirstHVACIteration ! TRUE if first HVAC iteration
  INTEGER, INTENT (IN)    :: AirLoopNum         ! air loop index
  REAL(r64),    INTENT (INOUT) :: QZnReq             ! Heating/Cooling load for all zones
  REAL(r64),    INTENT (INOUT) :: OnOffAirFlowRatio  ! Ratio of compressor ON airflow to average airflow over timestep
  LOGICAL, INTENT (INOUT) :: HXUnitOn           ! flag to enable heat exchanger

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER             :: InNode                           ! Inlet node number in CBVAV loop
  INTEGER             :: OutNode                          ! Outlet node number in CBVAV loop
  INTEGER             :: MixerOutsideAirNode              ! Outside air node number in CBVAV loop
  REAL(r64)           :: RhoAir                           ! Air density at InNode
  LOGICAL,SAVE        :: MyOneTimeFlag = .TRUE.           ! Initialization flag
  LOGICAL, ALLOCATABLE, SAVE, DIMENSION(:) :: MyEnvrnFlag ! Used for initializations each begin environment flag
  LOGICAL, ALLOCATABLE, SAVE, DIMENSION(:) :: MySizeFlag  ! Used for sizing CBVAV inputs one time
  LOGICAL, ALLOCATABLE, SAVE, DIMENSION(:) :: MyPlantScanFlag  ! Used for initializations plant component for heating coils
  REAL(r64)           :: QSensUnitOut                     ! Output of CBVAV system with coils off
  REAL(r64)           :: OutsideAirMultiplier             ! Outside air multiplier schedule (= 1.0 if no schedule)
  LOGICAL                        :: FanErrFlag = .FALSE.  ! Error flag returned during CALL to GetFanType
  INTEGER                        :: FanIndex              ! Index to CBVAV's supply air fan
  CHARACTER(len=MaxNameLength)   :: CurrentModuleObject        ! Object type for error messages
  LOGICAL                        :: EMSSetpointCheck = .FALSE. ! local temporary
  LOGICAL                        :: ErrorsFound=.false.  ! Set to true if errors in input, fatal at end of routine
  INTEGER                        :: SteamIndex           ! steam coil index
  REAL(r64)                      :: FluidDensity         ! steam or water coil fluid density
  REAL(r64)                      :: CoilMaxVolFlowRate   ! water or steam max volumetric water flow rate
  REAL(r64)                      :: QCoilActual          ! actual CBVAV steam heating coil load met (W)
  LOGICAL                        :: ErrorFlag            ! local error flag returned from data mining
  REAL(r64)                      :: mdot                 ! heating coil fluid mass flow rate, kg/s

  InNode  = CBVAV(CBVAVNum)%AirInNode
  OutNode = CBVAV(CBVAVNum)%AirOutNode

! Do the one time initializations
  IF (MyOneTimeFlag) THEN

    ALLOCATE(MyEnvrnFlag(NumCBVAV))
    ALLOCATE(MySizeFlag(NumCBVAV))
    ALLOCATE(MyPlantScanFlag(NumCBVAV))
    MyEnvrnFlag = .TRUE.
    MySizeFlag = .TRUE.
    MyPlantScanFlag = .TRUE.

    MyOneTimeFlag = .FALSE.

  END IF

  IF (MyPlantScanFlag(CBVAVNum) .AND. ALLOCATED(PlantLoop)) THEN
    IF ( (CBVAV(CBVAVNum)%HeatCoilType_Num == Coil_HeatingWater) .OR. &
         (CBVAV(CBVAVNum)%HeatCoilType_Num == Coil_HeatingSteam) ) THEN
      IF (CBVAV(CBVAVNum)%HeatCoilType_Num == Coil_HeatingWater) THEN

        ErrorFlag=.false.
        CALL ScanPlantLoopsForObject( CBVAV(CBVAVNum)%HeatCoilName, &
                                          TypeOf_CoilWaterSimpleHeating , &
                                          CBVAV(CBVAVNum)%LoopNum, &
                                          CBVAV(CBVAVNum)%LoopSide, &
                                          CBVAV(CBVAVNum)%BranchNum, &
                                          CBVAV(CBVAVNum)%CompNum,   &
                                          ErrFlag=ErrorFlag)
        IF (ErrorFlag) THEN
          CALL ShowFatalError('InitCBVAV: Program terminated for previous conditions.')
        ENDIF

        CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                                 CBVAV(CBVAVNum)%HeatCoilName,ErrorsFound)

        IF(CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow .GT. 0.0d0)THEN
          FluidDensity = GetDensityGlycol(PlantLoop(CBVAV(CBVAVNum)%LoopNum)%FluidName, &
                                InitConvTemp, &
                                PlantLoop(CBVAV(CBVAVNum)%LoopNum)%FluidIndex, &
                                'InitCBVAV')
          CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                                 CBVAV(CBVAVNum)%HeatCoilName,ErrorsFound) * FluidDensity
        END IF

      ELSEIF (CBVAV(CBVAVNum)%HeatCoilType_Num == Coil_HeatingSteam) THEN

        ErrorFlag=.false.
        CALL ScanPlantLoopsForObject( CBVAV(CBVAVNum)%HeatCoilName, &
                                      TypeOf_CoilSteamAirHeating , &
                                      CBVAV(CBVAVNum)%LoopNum, &
                                      CBVAV(CBVAVNum)%LoopSide, &
                                      CBVAV(CBVAVNum)%BranchNum, &
                                      CBVAV(CBVAVNum)%CompNum,   &
                                      ErrFlag=ErrorFlag)

        IF (ErrorFlag) THEN
          CALL ShowFatalError('InitCBVAV: Program terminated for previous conditions.')
        ENDIF

        CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow = GetCoilMaxSteamFlowRate(CBVAV(CBVAVNum)%HeatCoilIndex,ErrorsFound)

        IF(CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow .GT. 0.0d0)THEN
          SteamIndex = 0 ! Function GetSatDensityRefrig will look up steam index if 0 is passed
          FluidDensity=GetSatDensityRefrig('STEAM',TempSteamIn,1.0d0,SteamIndex,'InitCBVAV')
          CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow =   &
             GetCoilMaxSteamFlowRate(CBVAV(CBVAVNum)%HeatCoilIndex,ErrorsFound) * FluidDensity
        END IF

      ENDIF

         !fill outlet node for heating coil
      CBVAV(CBVAVNum)%CoilOutletNode =  &
            PlantLoop(CBVAV(CBVAVNum)%LoopNum)%LoopSide(CBVAV(CBVAVNum)%LoopSide) &
                      %Branch(CBVAV(CBVAVNum)%BranchNum)%Comp(CBVAV(CBVAVNum)%CompNum)%NodeNumOut
      MyPlantScanFlag(CBVAVNum) = .FALSE.

    ELSE ! CBVAV is not connected to plant
      MyPlantScanFlag(CBVAVNum) = .FALSE.
    ENDIF
  ELSEIF (MyPlantScanFlag(CBVAVNum) .AND. .NOT. AnyPlantInModel) THEN
    MyPlantScanFlag(CBVAVNum) = .FALSE.
  ENDIF

  IF ( .NOT. SysSizingCalc .AND. MySizeFlag(CBVAVNum) ) THEN
    CALL SizeCBVAV(CBVAVNum)
    ! Pass the fan cycling schedule index up to the air loop. Set the air loop unitary system flag.
    AirLoopControlInfo(AirLoopNum)%CycFanSchedPtr = CBVAV(CBVAVNum)%FanOpModeSchedPtr
!   Set UnitarySys flag to FALSE and let the heating coil autosize independently of the cooling coil
    AirLoopControlInfo(AirLoopNum)%UnitarySys = .FALSE.
    AirLoopControlInfo(AirLoopNum)%FanOpMode = CBVAV(CBVAVNum)%OpMode
    MySizeFlag(CBVAVNum) = .FALSE.
  END IF

! Do the Begin Environment initializations
  IF (BeginEnvrnFlag .and. MyEnvrnFlag(CBVAVNum)) THEN
    MixerOutsideAirNode = CBVAV(CBVAVNum)%MixerOutsideAirNode
    RhoAir = StdRhoAir
    ! set the mass flow rates from the input volume flow rates
    CBVAV(CBVAVNum)%MaxCoolAirMassFlow = RhoAir*CBVAV(CBVAVNum)%MaxCoolAirVolFlow
    CBVAV(CBVAVNum)%CoolOutAirMassFlow = RhoAir*CBVAV(CBVAVNum)%CoolOutAirVolFlow
    CBVAV(CBVAVNum)%MaxHeatAirMassFlow = RhoAir*CBVAV(CBVAVNum)%MaxHeatAirVolFlow
    CBVAV(CBVAVNum)%HeatOutAirMassFlow = RhoAir*CBVAV(CBVAVNum)%HeatOutAirVolFlow
    CBVAV(CBVAVNum)%MaxNoCoolHeatAirMassFlow = RhoAir*CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow
    CBVAV(CBVAVNum)%NoCoolHeatOutAirMassFlow = RhoAir*CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow
    ! set the node max and min mass flow rates
    Node(MixerOutsideAirNode)%MassFlowRateMax = MAX(CBVAV(CBVAVNum)%CoolOutAirMassFlow,CBVAV(CBVAVNum)%HeatOutAirMassFlow)
    Node(MixerOutsideAirNode)%MassFlowRateMaxAvail = MAX(CBVAV(CBVAVNum)%CoolOutAirMassFlow,CBVAV(CBVAVNum)%HeatOutAirMassFlow)
    Node(MixerOutsideAirNode)%MassFlowRateMin = 0.0d0
    Node(MixerOutsideAirNode)%MassFlowRateMinAvail = 0.0d0
    Node(InNode)%MassFlowRateMax = MAX(CBVAV(CBVAVNum)%MaxCoolAirMassFlow,CBVAV(CBVAVNum)%MaxHeatAirMassFlow)
    Node(InNode)%MassFlowRateMaxAvail = MAX(CBVAV(CBVAVNum)%MaxCoolAirMassFlow,CBVAV(CBVAVNum)%MaxHeatAirMassFlow)
    Node(InNode)%MassFlowRateMin = 0.0d0
    Node(InNode)%MassFlowRateMinAvail = 0.0d0
    Node(OutNode)%Temp = Node(InNode)%Temp
    Node(OutNode)%HumRat = Node(InNode)%HumRat
    Node(OutNode)%Enthalpy = Node(InNode)%Enthalpy
    Node(CBVAV(CBVAVNum)%MixerReliefAirNode) = Node(MixerOutsideAirNode)
    MyEnvrnFlag(CBVAVNum) = .FALSE.
    CBVAV(CBVAVNum)%LastMode = HeatingMode
!   set fluid-side hardware limits
    IF(CBVAV(CBVAVNum)%CoilControlNode .GT. 0)THEN
       !    If water coil max water flow rate is autosized, simulate once in order to mine max water flow rate
      IF(CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow .EQ. Autosize)THEN
        IF (CBVAV(CBVAVNum)%HeatCoilType_Num == Coil_HeatingWater) THEN
            CALL SimulateWaterCoilComponents(CBVAV(CBVAVNum)%HeatCoilName,FirstHVACIteration, &
                                             CBVAV(CBVAVNum)%HeatCoilIndex)
            ErrorFlag = .FALSE.
            CoilMaxVolFlowRate = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                              CBVAV(CBVAVNum)%HeatCoilName,ErrorFlag)
            IF (ErrorFlag) Then
              ErrorsFound = .TRUE.
            ENDIF
            IF(CoilMaxVolFlowRate .NE. Autosize) THEN
              FluidDensity = GetDensityGlycol(PlantLoop(CBVAV(CBVAVNum)%LoopNum)%fluidName, &
                                     InitConvTemp, &
                                     PlantLoop(CBVAV(CBVAVNum)%LoopNum)%fluidIndex, &
                                     'InitCBVAV')
              CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow = CoilMaxVolFlowRate * FluidDensity
            ENDIF
        ENDIF
        IF (CBVAV(CBVAVNum)%HeatCoilType_Num == Coil_HeatingSteam) THEN
            CALL SimulateSteamCoilComponents(CBVAV(CBVAVNum)%HeatCoilName, &
                                             FirstHVACIteration,    &
                                             1.0d0, & !QCoilReq, simulate any load > 0 to get max capacity of steam coil
                                             CBVAV(CBVAVNum)%HeatCoilIndex, QCoilActual)
            ErrorFlag = .FALSE.
            CoilMaxVolFlowRate = GetCoilMaxSteamFlowRate(CBVAV(CBVAVNum)%HeatCoilIndex,ErrorFlag)
            IF (ErrorFlag) Then
              ErrorsFound = .TRUE.
            ENDIF
            IF(CoilMaxVolFlowRate .NE. Autosize) THEN
              SteamIndex = 0 ! Function GetSatDensityRefrig will look up steam index if 0 is passed
              FluidDensity=GetSatDensityRefrig('STEAM',TempSteamIn,1.0d0,SteamIndex,'InitCBVAV')
              CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow = CoilMaxVolFlowRate * FluidDensity
            ENDIF
        ENDIF
      ENDIF  ! end of IF(CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow .EQ. Autosize)THEN

      Call InitComponentNodes(0.d0, CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow, &
                                    CBVAV(CBVAVNum)%CoilControlNode, &
                                    CBVAV(CBVAVNum)%CoilOutletNode, &
                                    CBVAV(CBVAVNum)%LoopNum, &
                                    CBVAV(CBVAVNum)%LoopSide, &
                                    CBVAV(CBVAVNum)%BranchNum, &
                                    CBVAV(CBVAVNum)%CompNum )

    END IF  ! end of IF(CBVAV(CBVAVNum)%CoilControlNode .GT. 0)THEN
  END IF ! end one time inits

  IF (.NOT. BeginEnvrnFlag) THEN
    MyEnvrnFlag(CBVAVNum) = .TRUE.
  END IF

! IF CBVAV system was not autosized and the fan is autosized, check that fan volumetric flow rate is greater than CBVAV flow rates
  IF(.NOT. DoingSizing .AND. CBVAV(CBVAVNum)%CheckFanFlow)THEN
    CurrentModuleObject = 'AirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypass'
    FanErrFlag = .FALSE.
    CALL GetFanIndex(CBVAV(CBVAVNum)%FanName,FanIndex,FanErrFlag)
    IF (FanErrFlag) THEN
      CALL ShowContinueError('...Fan occurs in '//TRIM(CurrentModuleObject)//  &
                ' ='//TRIM(CBVAV(CBVAVNum)%Name))
    ELSE
!     Only get the fan volumetric flow rate if the fan is valid, otherwise GetFanVolFlow returns a 0 and
!     the following warnings are written to the error file.
      CALL GetFanVolFlow(FanIndex,CBVAV(CBVAVNum)%FanVolFlow)
    ENDIF
    IF(CBVAV(CBVAVNum)%FanVolFlow .NE. AutoSize)THEN
!     Check fan versus system supply air flow rates
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%MaxCoolAirVolFlow)THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' - air flow rate = ' &
                            //TRIM(TrimSigDigits(CBVAV(CBVAVNum)%FanVolFlow,7))//' in fan object ' &
                            //TRIM(CBVAV(CBVAVNum)%FanName)//' is less than the maximum CBVAV system air flow rate' &
                            //' when cooling is required ('//TRIM(TrimSigDigits(CBVAV(CBVAVNum)%MaxCoolAirVolFlow,7))//').')
        CALL ShowContinueError(' The CBVAV system flow rate when cooling is required is reset to the' &
                              //' fan flow rate and the simulation continues.')
        CALL ShowContinueError(' Occurs in Changeover-bypass VAV system = '//TRIM(CBVAV(CBVAVNum)%Name))
        CBVAV(CBVAVNum)%MaxCoolAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
      END IF
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%MaxHeatAirVolFlow)THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' - air flow rate = ' &
                            //TRIM(TrimSigDigits(CBVAV(CBVAVNum)%FanVolFlow,7))//' in fan object ' &
                            //TRIM(CBVAV(CBVAVNum)%FanName)//' is less than the maximum CBVAV system air flow rate' &
                            //' when heating is required ('//TRIM(TrimSigDigits(CBVAV(CBVAVNum)%MaxHeatAirVolFlow,7))//').')
        CALL ShowContinueError(' The CBVAV system flow rate when heating is required is reset to the' &
                              //' fan flow rate and the simulation continues.')
        CALL ShowContinueError(' Occurs in Changeover-bypass VAV system = '//TRIM(CBVAV(CBVAVNum)%Name))
        CBVAV(CBVAVNum)%MaxHeatAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
      END IF
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .AND. &
         CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .NE. 0.0d0)THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' - air flow rate = ' &
                            //TRIM(TrimSigDigits(CBVAV(CBVAVNum)%FanVolFlow,7))//' in fan object ' &
                            //TRIM(CBVAV(CBVAVNum)%FanName)//' is less than the maximum CBVAV system air flow rate when no ' &
                       //'heating or cooling is needed ('//TRIM(TrimSigDigits(CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow,7))//').')
        CALL ShowContinueError(' The CBVAV system flow rate when no heating or cooling is needed is reset to the' &
                              //' fan flow rate and the simulation continues.')
        CALL ShowContinueError(' Occurs in Changeover-bypass VAV system = '//TRIM(CBVAV(CBVAVNum)%Name))
        CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
      END IF
!     Check fan versus outdoor air flow rates
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%CoolOutAirVolFlow)THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' - air flow rate = ' &
                            //TRIM(TrimSigDigits(CBVAV(CBVAVNum)%FanVolFlow,7))//' in fan object ' &
                            //TRIM(CBVAV(CBVAVNum)%FanName)//' is less than the maximum CBVAV outdoor air flow rate' &
                            //' when cooling is required ('//TRIM(TrimSigDigits(CBVAV(CBVAVNum)%CoolOutAirVolFlow,7))//').')
        CALL ShowContinueError(' The CBVAV outdoor flow rate when cooling is required is reset to the' &
                              //' fan flow rate and the simulation continues.')
        CALL ShowContinueError(' Occurs in Changeover-bypass VAV system = '//TRIM(CBVAV(CBVAVNum)%Name))
        CBVAV(CBVAVNum)%CoolOutAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
      END IF
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%HeatOutAirVolFlow)THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' - air flow rate = ' &
                            //TRIM(TrimSigDigits(CBVAV(CBVAVNum)%FanVolFlow,7))//' in fan object ' &
                            //TRIM(CBVAV(CBVAVNum)%FanName)//' is less than the maximum CBVAV outdoor air flow rate' &
                            //' when heating is required ('//TRIM(TrimSigDigits(CBVAV(CBVAVNum)%HeatOutAirVolFlow,7))//').')
        CALL ShowContinueError(' The CBVAV outdoor flow rate when heating is required is reset to the' &
                              //' fan flow rate and the simulation continues.')
        CALL ShowContinueError(' Occurs in Changeover-bypass VAV system = '//TRIM(CBVAV(CBVAVNum)%Name))
        CBVAV(CBVAVNum)%HeatOutAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
      END IF
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow)THEN
        CALL ShowWarningError(TRIM(CurrentModuleObject)//' - air flow rate = ' &
                            //TRIM(TrimSigDigits(CBVAV(CBVAVNum)%FanVolFlow,7))//' in fan object ' &
                            //TRIM(CBVAV(CBVAVNum)%FanName)//' is less than the maximum CBVAV outdoor air flow rate when no ' &
                       //'heating or cooling is needed ('//TRIM(TrimSigDigits(CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow,7))//').')
        CALL ShowContinueError(' The CBVAV outdoor flow rate when no heating or cooling is needed is reset to the' &
                              //' fan flow rate and the simulation continues.')
        CALL ShowContinueError(' Occurs in Changeover-bypass VAV system = '//TRIM(CBVAV(CBVAVNum)%Name))
        CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
      END IF
      MixerOutsideAirNode = CBVAV(CBVAVNum)%MixerOutsideAirNode
      RhoAir = StdRhoAir
      ! set the mass flow rates from the reset volume flow rates
      CBVAV(CBVAVNum)%MaxCoolAirMassFlow = RhoAir*CBVAV(CBVAVNum)%MaxCoolAirVolFlow
      CBVAV(CBVAVNum)%CoolOutAirMassFlow = RhoAir*CBVAV(CBVAVNum)%CoolOutAirVolFlow
      CBVAV(CBVAVNum)%MaxHeatAirMassFlow = RhoAir*CBVAV(CBVAVNum)%MaxHeatAirVolFlow
      CBVAV(CBVAVNum)%HeatOutAirMassFlow = RhoAir*CBVAV(CBVAVNum)%HeatOutAirVolFlow
      CBVAV(CBVAVNum)%MaxNoCoolHeatAirMassFlow = RhoAir*CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow
      CBVAV(CBVAVNum)%NoCoolHeatOutAirMassFlow = RhoAir*CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow
      ! set the node max and min mass flow rates based on reset volume flow rates
      Node(MixerOutsideAirNode)%MassFlowRateMax = MAX(CBVAV(CBVAVNum)%CoolOutAirMassFlow,CBVAV(CBVAVNum)%HeatOutAirMassFlow)
      Node(MixerOutsideAirNode)%MassFlowRateMaxAvail = MAX(CBVAV(CBVAVNum)%CoolOutAirMassFlow,CBVAV(CBVAVNum)%HeatOutAirMassFlow)
      Node(MixerOutsideAirNode)%MassFlowRateMin = 0.0d0
      Node(MixerOutsideAirNode)%MassFlowRateMinAvail = 0.0d0
      Node(InNode)%MassFlowRateMax = MAX(CBVAV(CBVAVNum)%MaxCoolAirMassFlow,CBVAV(CBVAVNum)%MaxHeatAirMassFlow)
      Node(InNode)%MassFlowRateMaxAvail = MAX(CBVAV(CBVAVNum)%MaxCoolAirMassFlow,CBVAV(CBVAVNum)%MaxHeatAirMassFlow)
      Node(InNode)%MassFlowRateMin = 0.0d0
      Node(InNode)%MassFlowRateMinAvail = 0.0d0
      Node(OutNode)%Temp = Node(InNode)%Temp
      Node(OutNode)%HumRat = Node(InNode)%HumRat
      Node(OutNode)%Enthalpy = Node(InNode)%Enthalpy
      Node(CBVAV(CBVAVNum)%MixerReliefAirNode) = Node(MixerOutsideAirNode)
      CBVAV(CBVAVNum)%CheckFanFlow = .FALSE.
      IF(CBVAV(CBVAVNum)%FanVolFlow .GT. 0.0d0)THEN
        CBVAV(CBVAVNum)%HeatingSpeedRatio = CBVAV(CBVAVNum)%MaxHeatAirVolFlow/CBVAV(CBVAVNum)%FanVolFlow
        CBVAV(CBVAVNum)%CoolingSpeedRatio = CBVAV(CBVAVNum)%MaxCoolAirVolFlow/CBVAV(CBVAVNum)%FanVolFlow
        CBVAV(CBVAVNum)%NoHeatCoolSpeedRatio = &
                                        CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow/CBVAV(CBVAVNum)%FanVolFlow
      END IF
    END IF
  END IF

  IF(CBVAV(CBVAVNum)%FanOpModeSchedPtr .GT. 0)THEN
    IF(GetCurrentScheduleValue(CBVAV(CBVAVNum)%FanOpModeSchedPtr) .EQ. 0.0d0)THEN
      CBVAV(CBVAVNum)%OpMode = CycFanCycCoil
    ELSE
      CBVAV(CBVAVNum)%OpMode = ContFanCycCoil
    END IF
  END IF

! Returns load only for zones requesting cooling (heating). If in deadband, Qzoneload = 0.
  CALL GetZoneLoads(CBVAVNum, QZnReq)

  IF(CBVAV(CBVAVNum)%OutAirSchPtr .GT. 0)THEN
    OutsideAirMultiplier = GetCurrentScheduleValue(CBVAV(CBVAVNum)%OutAirSchPtr)
  ELSE
    OutsideAirMultiplier = 1.0d0
  END IF

  ! Set the inlet node mass flow rate
  IF (CBVAV(CBVAVNum)%OpMode .EQ. ContFanCycCoil) THEN
  ! constant fan mode
    IF (CBVAV(CBVAVNum)%HeatCoolMode == HeatingMode) THEN
      CompOnMassFlow = CBVAV(CBVAVNum)%MaxHeatAirMassFlow
      CompOnFlowRatio = CBVAV(CBVAVNum)%HeatingSpeedRatio
      OACompOnMassFlow   = CBVAV(CBVAVNum)%HeatOutAirMassFlow * OutsideAirMultiplier
      CBVAV(CBVAVNum)%LastMode = HeatingMode
    ELSE IF (CBVAV(CBVAVNum)%HeatCoolMode == CoolingMode) THEN
      CompOnMassFlow = CBVAV(CBVAVNum)%MaxCoolAirMassFlow
      CompOnFlowRatio = CBVAV(CBVAVNum)%CoolingSpeedRatio
      OACompOnMassFlow   = CBVAV(CBVAVNum)%CoolOutAirMassFlow * OutsideAirMultiplier
      CBVAV(CBVAVNum)%LastMode = CoolingMode
    ELSE
      CompOnMassFlow = CBVAV(CBVAVNum)%MaxNoCoolHeatAirMassFlow
      CompOnFlowRatio = CBVAV(CBVAVNum)%NoHeatCoolSpeedRatio
      OACompOnMassFlow   = CBVAV(CBVAVNum)%NoCoolHeatOutAirMassFlow * OutsideAirMultiplier
    END IF

    IF (CBVAV(CBVAVNum)%AirFlowControl .EQ. UseCompressorOnFlow) THEN
      IF (CBVAV(CBVAVNum)%LastMode .EQ. HeatingMode) THEN
        CompOffMassFlow = CBVAV(CBVAVNum)%MaxHeatAirMassFlow
        CompOffFlowRatio = CBVAV(CBVAVNum)%HeatingSpeedRatio
        OACompOffMassFlow   = CBVAV(CBVAVNum)%HeatOutAirMassFlow * OutsideAirMultiplier
      ELSE
        CompOffMassFlow = CBVAV(CBVAVNum)%MaxCoolAirMassFlow
        CompOffFlowRatio = CBVAV(CBVAVNum)%CoolingSpeedRatio
        OACompOffMassFlow   = CBVAV(CBVAVNum)%CoolOutAirMassFlow * OutsideAirMultiplier
      END IF
    ELSE
      CompOffMassFlow = CBVAV(CBVAVNum)%MaxNoCoolHeatAirMassFlow
      CompOffFlowRatio = CBVAV(CBVAVNum)%NoHeatCoolSpeedRatio
      OACompOffMassFlow   = CBVAV(CBVAVNum)%NoCoolHeatOutAirMassFlow * OutsideAirMultiplier
    END IF
  ELSE
  ! cycling fan mode
    IF (CBVAV(CBVAVNum)%HeatCoolMode == HeatingMode) THEN
      CompOnMassFlow = CBVAV(CBVAVNum)%MaxHeatAirMassFlow
      CompOnFlowRatio = CBVAV(CBVAVNum)%HeatingSpeedRatio
      OACompOnMassFlow   = CBVAV(CBVAVNum)%HeatOutAirMassFlow * OutsideAirMultiplier
    ELSE IF (CBVAV(CBVAVNum)%HeatCoolMode == CoolingMode) THEN
      CompOnMassFlow = CBVAV(CBVAVNum)%MaxCoolAirMassFlow
      CompOnFlowRatio = CBVAV(CBVAVNum)%CoolingSpeedRatio
      OACompOnMassFlow   = CBVAV(CBVAVNum)%CoolOutAirMassFlow * OutsideAirMultiplier
    ELSE
      CompOnMassFlow = CBVAV(CBVAVNum)%MaxCoolAirMassFlow
      CompOnFlowRatio = CBVAV(CBVAVNum)%CoolingSpeedRatio
      OACompOnMassFlow = CBVAV(CBVAVNum)%CoolOutAirMassFlow * OutsideAirMultiplier
    END IF
    CompOffMassFlow = 0.0d0
    CompOffFlowRatio = 0.0d0
    OACompOffMassFlow = 0.0d0
  END IF

! Check for correct control node at outlet of unit
  IF(CBVAV(CBVAVNum)%HumRatMaxCheck)THEN
    IF (CBVAV(CBVAVNum)%DehumidControlType .GT. 0)THEN
      IF(Node(OutNode)%HumRatMax .EQ. SensedNodeFlagValue)THEN
        IF (.NOT. AnyEnergyManagementSystemInModel) THEN
          CALL ShowWarningError('Unitary System:VAV:ChangeOverBypass = '//TRIM(CBVAV(CBVAVNum)%Name))
          CALL ShowContinueError('Use SetpointManager:SingleZone:Humidity:Maximum to place a humidity setpoint at' // &
                                 ' the air outlet node of the unitary system.')
          CALL ShowContinueError('Setting Dehumidification Control Type to None and simulation continues.')
          CBVAV(CBVAVNum)%DehumidControlType = 0
        ELSE
            ! need call to EMS to check node
          EMSSetpointCheck = .FALSE.
          CALL CheckIfNodeSetpointManagedByEMS(OutNode,iHumidityRatioMaxSetpoint, EMSSetpointCheck)
          IF (EMSSetpointCheck) THEN
            CALL ShowWarningError('Unitary System:VAV:ChangeOverBypass = '//TRIM(CBVAV(CBVAVNum)%Name))
            CALL ShowContinueError('Use SetpointManager:SingleZone:Humidity:Maximum to place a humidity setpoint at' // &
                                   ' the air outlet node of the unitary system.')
            CALL ShowContinueError('Or use an EMS Actuator to place a maximum humidity setpoint at' // &
                                   ' the air outlet node of the unitary system.')
            CALL ShowContinueError('Setting Dehumidification Control Type to None and simulation continues.')
            CBVAV(CBVAVNum)%DehumidControlType = 0
          ENDIF
        ENDIF
      END IF
      CBVAV(CBVAVNum)%HumRatMaxCheck = .FALSE.
    ELSE
      CBVAV(CBVAVNum)%HumRatMaxCheck = .FALSE.
    END IF
  END IF

  ! Set the inlet node mass flow rate
  IF (GetCurrentScheduleValue(CBVAV(CBVAVNum)%SchedPtr) .gt. 0.0d0 .AND. CompOnMassFlow .NE. 0.0d0) THEN
    OnOffAirFlowRatio = 1.0d0
    IF(FirstHVACIteration)THEN
      Node(CBVAV(CBVAVNum)%AirInNode)%MassFlowRate           = CompOnMassFlow
      Node(CBVAV(CBVAVNum)%MixerInletAirNode)%MassFlowRate   = CompOnMassFlow
      Node(CBVAV(CBVAVNum)%MixerOutsideAirNode)%MassFlowRate = OACompOnMassFlow
      Node(CBVAV(CBVAVNum)%MixerReliefAirNode)%MassFlowRate  = OACompOnMassFlow
      ByPassDuctFlowFraction = 0.0d0
      PartLoadFrac           = 0.0d0
    ELSE
      IF (CBVAV(CBVAVNum)%HeatCoolMode /= 0) THEN
        PartLoadFrac = 1.0d0
      ELSE
        PartLoadFrac = 0.0d0
      END IF
      IF(CBVAV(CBVAVNum)%OpMode .EQ. CycFanCycCoil) THEN
        ByPassDuctFlowFraction = 0.0d0
      ELSE
        ByPassDuctFlowFraction = MAX(0.0d0,1.0d0 - (Node(CBVAV(CBVAVNum)%AirInNode)%MassFlowRate / CompOnMassFlow ))
      END IF
    END IF
  ELSE
    PartLoadFrac = 0.0d0
    Node(CBVAV(CBVAVNum)%AirInNode)%MassFlowRate           = 0.0d0
    Node(CBVAV(CBVAVNum)%AirOutNode)%MassFlowRate          = 0.0d0
    Node(CBVAV(CBVAVNum)%AirOutNode)%MassFlowRateMaxAvail  = 0.0d0

    Node(CBVAV(CBVAVNum)%MixerInletAirNode)%MassFlowRate   = 0.0d0
    Node(CBVAV(CBVAVNum)%MixerOutsideAirNode)%MassFlowRate = 0.0d0
    Node(CBVAV(CBVAVNum)%MixerReliefAirNode)%MassFlowRate  = 0.0d0

    OnOffAirFlowRatio      = 1.0d0
    ByPassDuctFlowFraction = 0.0d0

  END IF

  CALL CalcCBVAV(CBVAVNum,FirstHVACIteration,PartLoadFrac,QSensUnitOut,QZnReq,OnOffAirFlowRatio, HXUnitOn)

! If unit is scheduled OFF, setpoint is equal to inlet node temperature.
  IF (GetCurrentScheduleValue(CBVAV(CBVAVNum)%SchedPtr) .EQ. 0.0d0) THEN
    CBVAV(CBVAVNum)%OutletTempSetpoint = Node(InNode)%Temp
    RETURN
  END IF

  CALL SetAverageAirFlow(CBVAVNum, OnOffAirFlowRatio, FirstHVACIteration)

  IF(FirstHVACIteration)CBVAV(CBVAVNum)%OutletTempSetpoint = CalcSetpointTempTarget(CBVAVNum)

! The setpoint is used to control the DX coils at their respective outlet nodes (not the unit outlet), correct
! for fan heat for draw thru units only (fan heat is included at the outlet of each coil when blowthru is used)
  CBVAV(CBVAVNum)%CoilTempSetpoint = CBVAV(CBVAVNum)%OutletTempSetpoint
  IF(CBVAV(CBVAVNum)%FanPlace == DrawThru)THEN
    CBVAV(CBVAVNum)%CoilTempSetpoint = CBVAV(CBVAVNum)%CoilTempSetpoint - &
                 (Node(CBVAV(CBVAVNum)%AirOutNode)%Temp-Node(CBVAV(CBVAVNum)%FanInletNodeNum)%Temp)
  END IF

  IF(FirstHVACIteration) THEN
    IF (CBVAV(CBVAVNum)%HeatCoilType_Num == Coil_HeatingWater) THEN
            CALL SimulateWaterCoilComponents(CBVAV(CBVAVNum)%HeatCoilName,FirstHVACIteration, &
                                             CBVAV(CBVAVNum)%HeatCoilIndex)

      !     set air-side and steam-side mass flow rates
      Node(CBVAV(CBVAVNum)%HeatingCoilInletNode)%MassFlowRate = CompOnMassFlow
      mdot = CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow
      Call SetComponentFlowRate(mdot, &
                                CBVAV(CBVAVNum)%CoilControlNode, &
                                CBVAV(CBVAVNum)%CoilOutletNode, &
                                CBVAV(CBVAVNum)%LoopNum, &
                                CBVAV(CBVAVNum)%LoopSide, &
                                CBVAV(CBVAVNum)%BranchNum, &
                                CBVAV(CBVAVNum)%CompNum )

      !     simulate water coil to find operating capacity
      CALL SimulateWaterCoilComponents(CBVAV(CBVAVNum)%HeatCoilName,FirstHVACIteration, &
                                       CBVAV(CBVAVNum)%HeatCoilIndex, QCoilActual)
      CBVAV(CBVAVNum)%DesignSuppHeatingCapacity = QCoilActual

    END IF ! from IF(MSHeatPump(MSHeatPumpNum)%SuppHeatCoilType == Coil_HeatingWater) THEN

    IF(CBVAV(CBVAVNum)%HeatCoilType_Num == Coil_HeatingSteam) THEN

      !     set air-side and steam-side mass flow rates
      Node(CBVAV(CBVAVNum)%HeatingCoilInletNode)%MassFlowRate = CompOnMassFlow
      mdot = CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow
      Call SetComponentFlowRate(mdot, &
                                CBVAV(CBVAVNum)%CoilControlNode, &
                                CBVAV(CBVAVNum)%CoilOutletNode, &
                                CBVAV(CBVAVNum)%LoopNum, &
                                CBVAV(CBVAVNum)%LoopSide, &
                                CBVAV(CBVAVNum)%BranchNum, &
                                CBVAV(CBVAVNum)%CompNum )

!     simulate steam coil to find operating capacity
      CALL SimulateSteamCoilComponents(CBVAV(CBVAVNum)%HeatCoilName, &
                                       FirstHVACIteration,    &
                                       1.0d0, & !QCoilReq, simulate any load > 0 to get max capacity of steam coil
                                       CBVAV(CBVAVNum)%HeatCoilIndex, QCoilActual)
      CBVAV(CBVAVNum)%DesignSuppHeatingCapacity = QCoilActual

    END IF ! from IF(CBVAV(CBVAVNum)%HeatCoilType_Num == Coil_HeatingSteam) THEN
  END IF ! from IF( FirstHVACIteration ) THEN

  IF(CBVAV(CBVAVNum)%HeatCoolMode == 0 .AND. CBVAV(CBVAVNum)%OpMode == CycFanCycCoil .OR. CompOnMassFlow .EQ. 0.0d0)THEN
    QZnReq = 0.0d0
    PartLoadFrac = 0.0d0
    Node(CBVAV(CBVAVNum)%AirInNode)%MassFlowRate           = 0.0d0
    Node(CBVAV(CBVAVNum)%AirOutNode)%MassFlowRateMaxAvail  = 0.0d0
    Node(CBVAV(CBVAVNum)%MixerInletAirNode)%MassFlowRate   = 0.0d0
    Node(CBVAV(CBVAVNum)%MixerOutsideAirNode)%MassFlowRate = 0.0d0
    Node(CBVAV(CBVAVNum)%MixerReliefAirNode)%MassFlowRate  = 0.0d0
  END IF

  RETURN
END SUBROUTINE InitCBVAV

SUBROUTINE SizeCBVAV(CBVAVNum)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2006
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine is for sizing changeover-bypass VAV components.

          ! METHODOLOGY EMPLOYED:
          ! Obtains flow rates from the zone sizing arrays.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DataSizing
  USE InputProcessor
  USE ReportSizingManager, ONLY: ReportSizingOutput

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN) :: CBVAVNum       ! Index to CBVAV system

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
          ! na

  IF (CBVAV(CBVAVNum)%MaxCoolAirVolFlow == AutoSize) THEN

    IF (CurSysNum > 0) THEN

      CALL CheckSysSizing(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name)
      CBVAV(CBVAVNum)%MaxCoolAirVolFlow   = FinalSysSizing(CurSysNum)%DesMainVolFlow
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%MaxCoolAirVolFlow .AND. CBVAV(CBVAVNum)%FanVolFlow .NE. AutoSize)THEN
        CBVAV(CBVAVNum)%MaxCoolAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
        CALL ShowWarningError(TRIM(CBVAV(CBVAVNum)%UnitType)//' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')
        CALL ShowContinueError('The CBVAV system supply air fan air flow rate is less than the autosized value' &
                             //' for the maximum air flow rate in cooling mode. Consider autosizing the fan for' &
                             //' this simulation.')
        CALL ShowContinueError('The maximum air flow rate in cooling mode ' &
                             //'is reset to the supply air fan flow rate and the simulation continues.')
      END IF
      IF (CBVAV(CBVAVNum)%MaxCoolAirVolFlow < SmallAirVolFlow) THEN
        CBVAV(CBVAVNum)%MaxCoolAirVolFlow = 0.0d0
      END IF
      CALL ReportSizingOutput(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name, &
                              'maximum cooling air flow rate [m3/s]', CBVAV(CBVAVNum)%MaxCoolAirVolFlow)

    END IF

  END IF

  IF (CBVAV(CBVAVNum)%MaxHeatAirVolFlow == AutoSize) THEN

    IF (CurSysNum > 0) THEN

      CALL CheckSysSizing(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name)
      CBVAV(CBVAVNum)%MaxHeatAirVolFlow   = FinalSysSizing(CurSysNum)%DesMainVolFlow
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%MaxHeatAirVolFlow .AND. CBVAV(CBVAVNum)%FanVolFlow .NE. AutoSize)THEN
        CBVAV(CBVAVNum)%MaxHeatAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
        CALL ShowWarningError(TRIM(CBVAV(CBVAVNum)%UnitType)//' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')
        CALL ShowContinueError('The CBVAV system supply air fan air flow rate is less than the autosized value' &
                             //' for the maximum air flow rate in heating mode. Consider autosizing the fan for' &
                             //' this simulation.')
        CALL ShowContinueError('The maximum air flow rate in heating mode ' &
                             //'is reset to the supply air fan flow rate and the simulation continues.')
      END IF
      IF (CBVAV(CBVAVNum)%MaxHeatAirVolFlow < SmallAirVolFlow) THEN
        CBVAV(CBVAVNum)%MaxHeatAirVolFlow = 0.0d0
      END IF
      CALL ReportSizingOutput(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name, &
                              'maximum heating air flow rate [m3/s]', CBVAV(CBVAVNum)%MaxHeatAirVolFlow)

    END IF

  END IF

  IF (CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow == AutoSize) THEN

    IF (CurSysNum > 0) THEN

      CALL CheckSysSizing(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name)
      CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow .AND. &
         CBVAV(CBVAVNum)%FanVolFlow .NE. AutoSize)THEN
        CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
        CALL ShowWarningError(TRIM(CBVAV(CBVAVNum)%UnitType)//' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')
        CALL ShowContinueError('The CBVAV system supply air fan air flow rate is less than the autosized value' &
                             //' for the maximum air flow rate when no heating or cooling is needed. Consider' &
                             //' autosizing the fan for this simulation.')
        CALL ShowContinueError('The maximum air flow rate when no heating or cooling is needed ' &
                             //'is reset to the supply air fan flow rate and the simulation continues.')
      END IF
      IF (CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow < SmallAirVolFlow) THEN
        CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow = 0.0d0
      END IF

      CALL ReportSizingOutput(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name, &
                              'maximum air flow rate when compressor/coil is off [m3/s]', CBVAV(CBVAVNum)%MaxNoCoolHeatAirVolFlow)

    END IF

  END IF

  IF (CBVAV(CBVAVNum)%CoolOutAirVolFlow == AutoSize) THEN

    IF (CurSysNum > 0) THEN

      CALL CheckSysSizing(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name)
      CBVAV(CBVAVNum)%CoolOutAirVolFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%CoolOutAirVolFlow .AND. CBVAV(CBVAVNum)%FanVolFlow .NE. AutoSize)THEN
        CBVAV(CBVAVNum)%CoolOutAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
        CALL ShowWarningError(TRIM(CBVAV(CBVAVNum)%UnitType)//' "'//TRIM(CBVAV(CBVAVNum)%Name)//'"')
        CALL ShowContinueError('The CBVAV system supply air fan air flow rate is less than the autosized value' &
                             //' for the outdoor air flow rate in cooling mode. Consider autosizing the fan for' &
                             //' this simulation.')
        CALL ShowContinueError('The outdoor air flow rate in cooling mode ' &
                             //'is reset to the supply air fan flow rate and the simulation continues.')
      END IF
      IF (CBVAV(CBVAVNum)%CoolOutAirVolFlow < SmallAirVolFlow) THEN
        CBVAV(CBVAVNum)%CoolOutAirVolFlow = 0.0d0
      END IF
      CALL ReportSizingOutput(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name, &
                              'maximum outside air flow rate in cooling [m3/s]',CBVAV(CBVAVNum)%CoolOutAirVolFlow)

    END IF

  END IF

  IF (CBVAV(CBVAVNum)%HeatOutAirVolFlow == AutoSize) THEN

    IF (CurSysNum > 0) THEN

      CALL CheckSysSizing(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name)
      CBVAV(CBVAVNum)%HeatOutAirVolFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%HeatOutAirVolFlow .AND. CBVAV(CBVAVNum)%FanVolFlow .NE. AutoSize)THEN
        CBVAV(CBVAVNum)%HeatOutAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
        CALL ShowContinueError('The CBVAV system supply air fan air flow rate is less than the autosized value' &
                             //' for the outdoor air flow rate in heating mode. Consider autosizing the fan for' &
                             //' this simulation.')
        CALL ShowContinueError('The outdoor air flow rate in heating mode ' &
                             //'is reset to the supply air fan flow rate and the simulation continues.')
      END IF
      IF (CBVAV(CBVAVNum)%HeatOutAirVolFlow < SmallAirVolFlow) THEN
        CBVAV(CBVAVNum)%HeatOutAirVolFlow = 0.0d0
      END IF
      CALL ReportSizingOutput(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name, &
                              'maximum outdoor air flow rate in heating [m3/s]',CBVAV(CBVAVNum)%CoolOutAirVolFlow)

    END IF

  END IF

  IF (CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow == AutoSize) THEN

    IF (CurSysNum > 0) THEN

      CALL CheckSysSizing(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name)
      CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
      IF(CBVAV(CBVAVNum)%FanVolFlow .LT. CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow .AND. &
         CBVAV(CBVAVNum)%FanVolFlow .NE. AutoSize)THEN
        CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow = CBVAV(CBVAVNum)%FanVolFlow
        CALL ShowContinueError('The CBVAV system supply air fan air flow rate is less than the autosized value' &
                             //' for the outdoor air flow rate when no heating or cooling is needed. Consider' &
                             //' autosizing the fan for this simulation.')
        CALL ShowContinueError('The outdoor air flow rate when no heating or cooling is needed ' &
                             //'is reset to the supply air fan flow rate and the simulation continues.')
      END IF
      IF (CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow < SmallAirVolFlow) THEN
        CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow = 0.0d0
      END IF
      CALL ReportSizingOutput(CBVAV(CBVAVNum)%UnitType, CBVAV(CBVAVNum)%Name, &
                            'maximum outdoor air flow rate when compressor is off [m3/s]',CBVAV(CBVAVNum)%NoCoolHeatOutAirVolFlow)

    END IF

  END IF

  RETURN
END SUBROUTINE SizeCBVAV

SUBROUTINE ControlCBVAVOutput(CBVAVNum,FirstHVACIteration,QZnReq,PartLoadFrac,OnOffAirFlowRatio, HXUnitOn)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2006
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! Determine the part load fraction of the CBVAV system for this time step.

          ! METHODOLOGY EMPLOYED:
          ! Use RegulaFalsi technique to iterate on part-load ratio until convergence is achieved.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DataHVACGlobals,           ONLY: SmallTempDiff
  USE ScheduleManager,           ONLY: GetCurrentScheduleValue

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT   (IN)  :: CBVAVNum           ! Index to CBVAV system
  LOGICAL, INTENT   (IN)  :: FirstHVACIteration ! Flag for 1st HVAC iteration
  REAL(r64)   , INTENT (INOUT) :: QZnReq             ! Cooling or heating output needed by zone [W]
  REAL(r64)   , INTENT   (OUT) :: PartLoadFrac       ! Unit part load fraction
  REAL(r64)   , INTENT (INOUT) :: OnOffAirFlowRatio  ! Ratio of compressor ON airflow to AVERAGE airflow over timestep
  LOGICAL, INTENT (INOUT) :: HXUnitOn           ! flag to enable heat exchanger

          ! SUBROUTINE PARAMETER DEFINITIONS:
          !
  INTEGER, PARAMETER :: MaxIter  = 50           ! Maximum number of iterations

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  REAL(r64)          :: FullOutput              ! Unit full output when compressor is operating [W]

  PartLoadFrac  = 0.0d0

  IF (GetCurrentScheduleValue(CBVAV(CBVAVNum)%SchedPtr) .EQ. 0.0d0) RETURN

  ! Get operating result
  PartLoadFrac  = 1.0d0
  CALL CalcCBVAV(CBVAVNum, FirstHVACIteration, PartLoadFrac, FullOutput, QZnReq, OnOffAirFlowRatio, HXUnitOn)

  IF((Node(CBVAV(CBVAVNum)%AirOutNode)%Temp - CBVAV(CBVAVNum)%OutletTempSetpoint) .GT. SmallTempDiff .AND. &
      CBVAV(CBVAVNum)%HeatCoolMode .GT. 0 .AND. PartLoadFrac .LT. 1.0d0)THEN
    CALL CalcCBVAV(CBVAVNum, FirstHVACIteration, PartLoadFrac, FullOutput, QZnReq, OnOffAirFlowRatio, HXUnitOn)
  END IF

  RETURN

END SUBROUTINE ControlCBVAVOutput

SUBROUTINE CalcCBVAV(CBVAVNum,FirstHVACIteration,PartLoadFrac,LoadMet,QZnReq,OnOffAirFlowRatio, HXUnitOn)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2006
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! Simulate the components making up the changeover-bypass VAV system.

          ! METHODOLOGY EMPLOYED:
          ! Simulates the unit components sequentially in the air flow direction.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE Fans,                      ONLY: SimulateFanComponents
  USE DXCoils,                   ONLY: SimDXCoil, SimDXCoilMultiMode
  USE General,                   ONLY: SolveRegulaFalsi, RoundSigDigits
  USE MixedAir,                  ONLY: SimOAMixer
  USE DataHVACGlobals,           ONLY: SmallTempDiff
  USE Psychrometrics,            ONLY: PsyHFnTdbW, PsyCpAirFnWTdb, PsyTdpFnWPb
  USE HVACHXAssistedCoolingCoil, ONLY: SimHXAssistedCoolingCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT    (IN) :: CBVAVNum              ! Unit index in fan coil array
  LOGICAL, INTENT    (IN) :: FirstHVACIteration   ! Flag for 1st HVAC iteration
  REAL(r64)   , INTENT (INOUT) :: PartLoadFrac         ! Compressor part load fraction
  REAL(r64)   , INTENT   (OUT) :: LoadMet              ! Load met by unit (W)
  REAL(r64)   , INTENT (INOUT) :: QZnReq               ! Zone load (W)
  REAL(r64)   , INTENT (INOUT) :: OnOffAirFlowRatio    ! Ratio of compressor ON airflow to AVERAGE airflow over timestep
  LOGICAL, INTENT (IN)    :: HXUnitOn           ! flag to enable heat exchanger

          ! SUBROUTINE PARAMETER DEFINITIONS:
  INTEGER, PARAMETER  ::   MaxIte = 500           ! Maximum number of iterations

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER      :: OutletNode           ! CBVAV air outlet node
  INTEGER      :: InletNode            ! CBVAV air inlet node
  REAL(r64)    :: MinHumRat            ! Minimum humidity ratio for sensible capacity calculation (kg/kg)
  REAL(r64)    :: Par(6)               ! RegulaFalsi parameters
  INTEGER      :: SolFla               ! Flag of RegulaFalsi solver
  REAL(r64)    :: QHeater              ! Load to be met by heater [W]
  REAL(r64)    :: QHeaterActual        ! actual heating load met [W]
  REAL(r64)    :: CpAir                ! Specific heat of air [J/kg-K]
  INTEGER      :: MixerOutsideAirNode  ! Outside air node number in OA mixer
  INTEGER      :: MixerReliefAirNode   ! Relief air node number in OA mixer
  INTEGER      :: DehumidMode          ! Dehumidification mode (0=normal, 1=enhanced)
  REAL(r64)    :: ApproachTemp
  REAL(r64)    :: DesiredDewPoint
  REAL(r64)    :: OutdoorDryBulbTemp   ! Dry-bulb temperature at outdoor condenser
  REAL(r64)    :: OutdoorBaroPress     ! Barometric pressure at outdoor condenser
          ! FLOW

  OutletNode = CBVAV(CBVAVNum)%AirOutNode
  InletNode  = CBVAV(CBVAVNum)%AirInNode
  MixerOutsideAirNode = CBVAV(CBVAVNum)%MixerOutsideAirNode
  MixerReliefAirNode  = CBVAV(CBVAVNum)%MixerReliefAirNode
  IF (CBVAV(CBVAVNum)%CondenserNodeNum > 0) THEN
    OutdoorDryBulbTemp = Node(CBVAV(CBVAVNum)%CondenserNodeNum)%Temp
    OutdoorBaroPress   = Node(CBVAV(CBVAVNum)%CondenserNodeNum)%Press
  ELSE
    OutdoorDryBulbTemp = OutDryBulbTemp
    OutdoorBaroPress   = OutBaroPress
  ENDIF

  SaveCompressorPLR = 0.0d0

! Bypass excess system air through bypass duct and calculate new mixed air conditions at OA mixer inlet node
  Node(CBVAV(CBVAVNum)%MixerInletAirNode)%Temp = (1.0d0 - ByPassDuctFlowFraction) * Node(InletNode)%Temp + &
                                          ByPassDuctFlowFraction * Node(OutletNode)%Temp
  Node(CBVAV(CBVAVNum)%MixerInletAirNode)%HumRat = (1.0d0 - ByPassDuctFlowFraction) * Node(InletNode)%HumRat + &
                                          ByPassDuctFlowFraction * Node(OutletNode)%HumRat
  Node(CBVAV(CBVAVNum)%MixerInletAirNode)%Enthalpy = PsyHFnTdbW(Node(CBVAV(CBVAVNum)%MixerInletAirNode)%Temp, &
                                                               Node(CBVAV(CBVAVNum)%MixerInletAirNode)%HumRat)
  CALL SimOAMixer(CBVAV(CBVAVNum)%OAMixName,FirstHVACIteration,CBVAV(CBVAVNum)%OAMixIndex)

  IF (CBVAV(CBVAVNum)%FanPlace .EQ. BlowThru)&
       CALL SimulateFanComponents(CBVAV(CBVAVNum)%FanName,FirstHVACIteration,CBVAV(CBVAVNum)%FanIndex,FanSpeedRatio)

! Simulate cooling coil if zone load is negative (cooling load)
  IF (CBVAV(CBVAVNum)%HeatCoolMode == CoolingMode) THEN
    IF(OutdoorDryBulbTemp .GE. CBVAV(CBVAVNum)%MinOATCompressor)THEN

      SELECT CASE(CBVAV(CBVAVNum)%DXCoolCoilType_Num)

      CASE(CoilDX_CoolingHXAssisted)
        CALL SimHXAssistedCoolingCoil(CBVAV(CBVAVNum)%DXCoolCoilName,FirstHVACIteration,On,PartLoadFrac, &
                                      CBVAV(CBVAVNum)%CoolCoilCompIndex, ContFanCycCoil, HXUnitEnable=HXUnitOn)
        IF(Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp .LE. CBVAV(CBVAVNum)%CoilTempSetpoint)THEN
!         If coil inlet temp is already below the setpoint, simulated with coil off
          PartLoadFrac = 0.0d0
          CALL SimHXAssistedCoolingCoil(CBVAV(CBVAVNum)%DXCoolCoilName,FirstHVACIteration,Off,PartLoadFrac, &
                                        CBVAV(CBVAVNum)%CoolCoilCompIndex, ContFanCycCoil, HXUnitEnable=HXUnitOn)
        ELSE IF(Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp .LT. CBVAV(CBVAVNum)%CoilTempSetpoint .AND. &
                Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp .GT. CBVAV(CBVAVNum)%CoilTempSetpoint)THEN
          Par(1) = REAL(CBVAV(CBVAVNum)%CoolCoilCompIndex,r64)
          Par(2) = CBVAV(CBVAVNum)%CoilTempSetpoint
          Par(3) = OnOffAirFlowRatio
          Par(4) = REAL(CBVAVNum,r64)
          IF(FirstHVACIteration)THEN
            Par(5) = 1.0d0
          ELSE
            Par(5) = 0.0d0
          END IF
          IF(HXUnitOn)THEN
            Par(6) = 1.0d0
          ELSE
            Par(6) = 0.0d0
          END IF
          CALL SolveRegulaFalsi(SmallTempDiff, MaxIte, SolFla, PartLoadFrac, HXAssistDXCoilResidual, 0.0d0, 1.0d0, Par)
          CALL SimHXAssistedCoolingCoil(CBVAV(CBVAVNum)%DXCoolCoilName,FirstHVACIteration,On,PartLoadFrac, &
                                    CBVAV(CBVAVNum)%CoolCoilCompIndex, ContFanCycCoil, HXUnitEnable=HXUnitOn)
          IF (SolFla == -1 .AND. .NOT. WarmupFlag) THEN
            IF(CBVAV(CBVAVNum)%HXDXIterationExceeded .LT. 1)THEN
              CBVAV(CBVAVNum)%HXDXIterationExceeded = CBVAV(CBVAVNum)%HXDXIterationExceeded + 1
              CALL ShowWarningError('Iteration limit exceeded calculating HX assisted DX unit part-load ratio, for unit = '// &
                              TRIM(CBVAV(CBVAVNum)%DXCoolCoilName))
              CALL ShowContinueError('Calculated part-load ratio = '//TRIM(RoundSigDigits(PartLoadFrac,3)))
              CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation continues.'// &
                                            ' Occurrence info: ')
            ELSE
              CALL ShowRecurringWarningErrorAtEnd(TRIM(CBVAV(CBVAVNum)%Name)// &
                                        ', Iteration limit exceeded for HX assisted DX unit part-load ratio error continues.', &
                                           CBVAV(CBVAVNum)%HXDXIterationExceededIndex,PartLoadFrac,PartLoadFrac)
            END IF
          ELSE IF (SolFla == -2 .AND. .NOT. WarmupFlag) THEN
            PartLoadFrac = MAX(0.0d0,MIN(1.0d0,(Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp - CBVAV(CBVAVNum)%CoilTempSetpoint) / &
                           (Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp - Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp)))
            IF(CBVAV(CBVAVNum)%HXDXIterationFailed .LT. 1)THEN
              CBVAV(CBVAVNum)%HXDXIterationFailed = CBVAV(CBVAVNum)%HXDXIterationFailed + 1
              CALL ShowSevereError('HX assisted DX unit part-load ratio calculation failed: part-load ratio limits exceeded, ' &
                               //'for unit = '//TRIM(CBVAV(CBVAVNum)%DXCoolCoilName))
              CALL ShowContinueErrorTimeStamp('An estimated part-load ratio of '//TRIM(RoundSigDigits(PartLoadFrac,3))// &
                                            'will be used and the simulation continues. Occurrence info: ')
            ELSE
              CALL ShowRecurringWarningErrorAtEnd(TRIM(CBVAV(CBVAVNum)%Name)// &
                                        ', Part-load ratio calculation failed for HX assisted DX unit error continues.', &
                                           CBVAV(CBVAVNum)%HXDXIterationFailedIndex,PartLoadFrac,PartLoadFrac)
            END IF
          END IF
        END IF
      CASE(CoilDX_CoolingSingleSpeed)
        CALL SimDXCoil(CBVAV(CBVAVNum)%DXCoolCoilName,On,FirstHVACIteration,PartLoadFrac,CBVAV(CBVAVNum)%CoolCoilCompIndex,  &
           ContFanCycCoil, OnOffAirFlowRatio)
        IF(Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp .LT. CBVAV(CBVAVNum)%CoilTempSetpoint)THEN
!         If coil inlet temp is already below the setpoint, simulated with coil off
          PartLoadFrac = 0.0d0
          CALL SimDXCoil(CBVAV(CBVAVNum)%DXCoolCoilName,On,FirstHVACIteration,PartLoadFrac,CBVAV(CBVAVNum)%CoolCoilCompIndex,  &
             ContFanCycCoil, OnOffAirFlowRatio)
        ELSE IF(Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp .LT. CBVAV(CBVAVNum)%CoilTempSetpoint .AND. &
                Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp .GT. CBVAV(CBVAVNum)%CoilTempSetpoint)THEN
          Par(1) = REAL(CBVAV(CBVAVNum)%CoolCoilCompIndex,r64)
          Par(2) = CBVAV(CBVAVNum)%CoilTempSetpoint
          Par(3) = OnOffAirFlowRatio
          CALL SolveRegulaFalsi(SmallTempDiff, MaxIte, SolFla, PartLoadFrac, DOE2DXCoilResidual, 0.0d0, 1.0d0, Par)
          CALL SimDXCoil(CBVAV(CBVAVNum)%DXCoolCoilName,On,FirstHVACIteration,PartLoadFrac,  &
             CBVAV(CBVAVNum)%CoolCoilCompIndex,ContFanCycCoil, OnOffAirFlowRatio)
          IF (SolFla == -1 .AND. .NOT. WarmupFlag) THEN
            IF(CBVAV(CBVAVNum)%DXIterationExceeded .LT. 1)THEN
              CBVAV(CBVAVNum)%DXIterationExceeded = CBVAV(CBVAVNum)%DXIterationExceeded + 1
              CALL ShowWarningError('Iteration limit exceeded calculating DX unit part-load ratio, for unit = '// &
                              TRIM(CBVAV(CBVAVNum)%DXCoolCoilName))
              CALL ShowContinueError('Calculated part-load ratio = '//TRIM(RoundSigDigits(PartLoadFrac,3)))
              CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation continues.'// &
                                            ' Occurrence info: ')
            ELSE
              CALL ShowRecurringWarningErrorAtEnd(TRIM(CBVAV(CBVAVNum)%Name)// &
                                        ', Iteration limit exceeded for DX unit part-load ratio calculation error continues.', &
                                           CBVAV(CBVAVNum)%DXIterationExceededIndex,PartLoadFrac,PartLoadFrac)
            END IF
          ELSE IF (SolFla == -2 .AND. .NOT. WarmupFlag) THEN
            PartLoadFrac = MAX(0.0d0,MIN(1.0d0,(Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp - CBVAV(CBVAVNum)%CoilTempSetpoint) / &
                           (Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp - Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp)))
            IF(CBVAV(CBVAVNum)%DXIterationFailed .LT. 1)THEN
              CBVAV(CBVAVNum)%DXIterationFailed = CBVAV(CBVAVNum)%DXIterationFailed + 1
              CALL ShowSevereError('DX unit part-load ratio calculation failed: part-load ratio limits exceeded, for unit = '// &
                               TRIM(CBVAV(CBVAVNum)%DXCoolCoilName))
              CALL ShowContinueErrorTimeStamp('An estimated part-load ratio of '//TRIM(RoundSigDigits(PartLoadFrac,3))// &
                                            'will be used and the simulation continues. Occurrence info: ')
            ELSE
              CALL ShowRecurringWarningErrorAtEnd(TRIM(CBVAV(CBVAVNum)%Name)// &
                                        ', Part-load ratio calculation failed for DX unit error continues.', &
                                           CBVAV(CBVAVNum)%DXIterationFailedIndex,PartLoadFrac,PartLoadFrac)
            END IF
          END IF
        END IF

      CASE (CoilDX_CoolingTwoStageWHumControl)  ! Coil:Cooling:DX:TwoStageWithHumidityControlMode
                                                 ! formerly (v3 and beyond) Coil:DX:MultiMode:CoolingEmpirical

        ! If DXCoolingSystem runs with a cooling load then set PartLoadFrac on Cooling System and the Mass Flow
        ! Multimode coil will switch to enhanced dehumidification if available and needed, but it
        ! still runs to meet the sensible load

        ! Determine required part load for normal mode

        ! Get full load result
        DehumidMode  = 0
        CBVAV(CBVAVNum)%DehumidificationMode = DehumidMode
        CALL SimDXCoilMultiMode(CBVAV(CBVAVNum)%DXCoolCoilName,On,FirstHVACIteration,PartLoadFrac,DehumidMode,  &
           CBVAV(CBVAVNum)%CoolCoilCompIndex,ContFanCycCoil)
        IF (Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp < CBVAV(CBVAVNum)%CoilTempSetpoint) THEN
          PartLoadFrac = 0.0d0
          CALL SimDXCoilMultiMode(CBVAV(CBVAVNum)%DXCoolCoilName,On,FirstHVACIteration,PartLoadFrac,DehumidMode, &
                                  CBVAV(CBVAVNum)%CoolCoilCompIndex,ContFanCycCoil)
        ELSE IF (Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp > CBVAV(CBVAVNum)%CoilTempSetpoint) THEN
          PartLoadFrac = 1.0d0
        ELSE
          Par(1) = REAL(CBVAV(CBVAVNum)%CoolCoilCompIndex,r64)
          Par(2) = CBVAV(CBVAVNum)%CoilTempSetpoint
          ! Dehumidification mode = 0 for normal mode, 1+ for enhanced mode
          Par(3) = REAL(DehumidMode,r64)
          CALL SolveRegulaFalsi(SmallTempDiff, MaxIte, SolFla, PartLoadFrac, MultiModeDXCoilResidual, 0.0d0, 1.0d0, Par)
          IF (SolFla == -1) THEN
            IF(CBVAV(CBVAVNum)%MMDXIterationExceeded .LT. 1)THEN
              CBVAV(CBVAVNum)%MMDXIterationExceeded = CBVAV(CBVAVNum)%MMDXIterationExceeded + 1
              CALL ShowWarningError('Iteration limit exceeded calculating DX unit part-load ratio, for unit='// &
                            TRIM(CBVAV(CBVAVNum)%Name))
              CALL ShowContinueErrorTimeStamp('Part-load ratio returned = '//TRIM(RoundSigDigits(PartLoadFrac,2)))
              CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation continues.'// &
                                            ' Occurrence info: ')
            ELSE
              CALL ShowRecurringWarningErrorAtEnd(TRIM(CBVAV(CBVAVNum)%Name)// &
                                      ', Iteration limit exceeded calculating DX unit part-load ratio error continues.', &
                                         CBVAV(CBVAVNum)%MMDXIterationExceededIndex,PartLoadFrac,PartLoadFrac)
            END IF
          ELSE IF (SolFla == -2) THEN
            PartLoadFrac = MAX(0.0d0,MIN(1.0d0,(Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp - CBVAV(CBVAVNum)%CoilTempSetpoint) / &
                         (Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp - Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp)))
            IF(CBVAV(CBVAVNum)%MMDXIterationFailed .LT. 1)THEN
              CBVAV(CBVAVNum)%MMDXIterationFailed = CBVAV(CBVAVNum)%MMDXIterationFailed + 1
              CALL ShowSevereError('DX unit part-load ratio calculation failed: part-load ratio limits exceeded, for unit='// &
                             TRIM(CBVAV(CBVAVNum)%Name))
              CALL ShowContinueError('Estimated part-load ratio = '//TRIM(RoundSigDigits(PartLoadFrac,3)))
              CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation continues.'// &
                                              ' Occurrence info: ')
            ELSE
              CALL ShowRecurringWarningErrorAtEnd(TRIM(CBVAV(CBVAVNum)%Name)// &
                                      ', Part-load ratio calculation failed for DX unit error continues.', &
                                         CBVAV(CBVAVNum)%MMDXIterationFailedIndex,PartLoadFrac,PartLoadFrac)
            END IF
          END IF
        END IF

       ! If humidity setpoint is not satisfied and humidity control type is Multimode,
       ! then turn on enhanced dehumidification mode 1

       IF (( Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%HumRat > Node(OutletNode)%HumRatMax ) .AND. &
           ( Node(CBVAV(CBVAVNum)%DXCoilInletNode)%HumRat > Node(OutletNode)%HumRatMax ) .AND. &
           ( CBVAV(CBVAVNum)%DehumidControlType .EQ. DehumidControl_Multimode ) .AND. &
             Node(OutletNode)%HumRatMax .GT. 0.0d0) THEN

         ! Determine required part load for enhanced dehumidification mode 1

         ! Get full load result
         PartLoadFrac = 1.0d0
         DehumidMode  = 1
         CBVAV(CBVAVNum)%DehumidificationMode = DehumidMode
         CALL SimDXCoilMultiMode(CBVAV(CBVAVNum)%DXCoolCoilName,On,FirstHVACIteration,PartLoadFrac,DehumidMode,  &
            CBVAV(CBVAVNum)%CoolCoilCompIndex, ContFanCycCoil)
         IF (Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp < CBVAV(CBVAVNum)%CoilTempSetpoint) THEN
           PartLoadFrac = 0.0d0
         ELSE IF (Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp > CBVAV(CBVAVNum)%CoilTempSetpoint) THEN
           PartLoadFrac = 1.0d0
         ELSE
           Par(1) = REAL(CBVAV(CBVAVNum)%CoolCoilCompIndex,r64)
           Par(2) = CBVAV(CBVAVNum)%CoilTempSetpoint
           ! Dehumidification mode = 0 for normal mode, 1+ for enhanced mode
           Par(3) = REAL(DehumidMode,r64)
           CALL SolveRegulaFalsi(SmallTempDiff, MaxIte, SolFla, PartLoadFrac, MultiModeDXCoilResidual, 0.0d0, 1.0d0, Par)
           IF (SolFla == -1) THEN
             IF(CBVAV(CBVAVNum)%DMDXIterationExceeded .LT. 1)THEN
               CBVAV(CBVAVNum)%DMDXIterationExceeded = CBVAV(CBVAVNum)%DMDXIterationExceeded + 1
               CALL ShowWarningError('Iteration limit exceeded calculating DX unit dehumidifying part-load ratio, '// &
                                 'for unit = '//TRIM(CBVAV(CBVAVNum)%Name))
               CALL ShowContinueErrorTimeStamp('Part-load ratio returned='//TRIM(RoundSigDigits(PartLoadFrac,2)))
               CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation continues.'// &
                                            ' Occurrence info: ')
             ELSE
               CALL ShowRecurringWarningErrorAtEnd(TRIM(CBVAV(CBVAVNum)%Name)// &
                                     ', Iteration limit exceeded calculating DX unit dehumidifying part-load ratio error ' &
                                        //'continues.',CBVAV(CBVAVNum)%DMDXIterationExceededIndex,PartLoadFrac,PartLoadFrac)
             END IF
           ELSE IF (SolFla == -2) THEN
             PartLoadFrac = MAX(0.0d0,MIN(1.0d0,(Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp-CBVAV(CBVAVNum)%CoilTempSetpoint) / &
                               (Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp - Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp)))
             IF(CBVAV(CBVAVNum)%DMDXIterationFailed .LT. 1)THEN
                CBVAV(CBVAVNum)%DMDXIterationFailed = CBVAV(CBVAVNum)%DMDXIterationFailed + 1
               CALL ShowSevereError('DX unit dehumidifying part-load ratio calculation failed: part-load ratio '// &
                                    'limits exceeded, for unit = '//TRIM(CBVAV(CBVAVNum)%Name))
               CALL ShowContinueError('Estimated part-load ratio = '//TRIM(RoundSigDigits(PartLoadFrac,3)))
               CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation continues.'// &
                                               ' Occurrence info: ')
             ELSE
               CALL ShowRecurringWarningErrorAtEnd(TRIM(CBVAV(CBVAVNum)%Name)// &
                                     ', Dehumidifying part-load ratio calculation failed for DX unit error continues.', &
                                        CBVAV(CBVAVNum)%DMDXIterationFailedIndex,PartLoadFrac,PartLoadFrac)
             END IF
           END IF
         END IF
       END IF ! End if humidity ratio setpoint not met - multimode humidity control

          ! If humidity setpoint is not satisfied and humidity control type is CoolReheat,
          ! then run to meet latent load

          IF (( Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%HumRat > Node(OutletNode)%HumRatMax) .AND. &
              ( Node(CBVAV(CBVAVNum)%DXCoilInletNode)%HumRat > Node(OutletNode)%HumRatMax) .AND. &
              (CBVAV(CBVAVNum)%DehumidControlType .EQ. DehumidControl_CoolReheat) .AND. &
               Node(OutletNode)%HumRatMax .GT. 0.0d0) THEN

            ! Determine revised desired outlet temperature  - use approach temperature control strategy
            ! based on CONTROLLER:SIMPLE TEMPANDHUMRAT control type.

            ! Calculate the approach temperature (difference between SA dry-bulb temp and SA dew point temp)
            ApproachTemp = Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp - &
                           PsyTdpFnWPb(Node(OutletNode)%HumRat,OutdoorBaroPress)
            ! Calculate the dew point temperature at the SA humidity ratio setpoint
            DesiredDewPoint = PsyTdpFnWPb(Node(OutletNode)%HumRatMax, OutdoorBaroPress)
            ! Adjust the calculated dew point temperature by the approach temp
            CBVAV(CBVAVNum)%CoilTempSetpoint = &
              MIN(CBVAV(CBVAVNum)%CoilTempSetpoint, (DesiredDewPoint + ApproachTemp))

            ! Determine required part load for cool reheat at adjusted DesiredOutletTemp

            ! Get full load result
            PartLoadFrac = 1.0d0
            DehumidMode  = 0
            CBVAV(CBVAVNum)%DehumidificationMode = DehumidMode
            CALL SimDXCoilMultiMode(CBVAV(CBVAVNum)%DXCoolCoilName,On,FirstHVACIteration,PartLoadFrac,DehumidMode,  &
               CBVAV(CBVAVNum)%CoolCoilCompIndex, ContFanCycCoil)
              IF (Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp < CBVAV(CBVAVNum)%CoilTempSetpoint) THEN
                PartLoadFrac = 0.0d0
              ELSE IF (Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp > CBVAV(CBVAVNum)%CoilTempSetpoint) THEN
                PartLoadFrac = 1.0d0
              ELSE
                Par(1) = REAL(CBVAV(CBVAVNum)%CoolCoilCompIndex,r64)
                Par(2) = CBVAV(CBVAVNum)%CoilTempSetpoint
                ! Dehumidification mode = 0 for normal mode, 1+ for enhanced mode
                Par(3) = REAL(DehumidMode,r64)
                CALL SolveRegulaFalsi(SmallTempDiff, MaxIte, SolFla, PartLoadFrac, MultiModeDXCoilResidual, 0.0d0, 1.0d0, Par)
                IF (SolFla == -1) THEN
                  IF(CBVAV(CBVAVNum)%CRDXIterationExceeded .LT. 1)THEN
                    CBVAV(CBVAVNum)%CRDXIterationExceeded = CBVAV(CBVAVNum)%CRDXIterationExceeded + 1
                    CALL ShowWarningError('Iteration limit exceeded calculating DX unit cool reheat part-load ratio, '// &
                                  'for unit = '//TRIM(CBVAV(CBVAVNum)%Name))
                    CALL ShowContinueErrorTimeStamp('Part-load ratio returned = '//TRIM(RoundSigDigits(PartLoadFrac,2)))
                    CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation '// &
                                            'continues. Occurrence info: ')
                  ELSE
                    CALL ShowRecurringWarningErrorAtEnd(TRIM(CBVAV(CBVAVNum)%Name)// &
                                 ', Iteration limit exceeded calculating cool reheat part-load ratio DX unit error continues.', &
                                    CBVAV(CBVAVNum)%CRDXIterationExceededIndex,PartLoadFrac,PartLoadFrac)
                  END IF
                ELSE IF (SolFla == -2) THEN
                  PartLoadFrac = MAX(0.0d0,MIN(1.0d0,  &
                                              (Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp-CBVAV(CBVAVNum)%CoilTempSetpoint) / &
                               (Node(CBVAV(CBVAVNum)%DXCoilInletNode)%Temp - Node(CBVAV(CBVAVNum)%DXCoilOutletNode)%Temp)))
                  IF(CBVAV(CBVAVNum)%CRDXIterationFailed .LT. 1)THEN
                    CBVAV(CBVAVNum)%CRDXIterationFailed = CBVAV(CBVAVNum)%CRDXIterationFailed + 1
                    CALL ShowSevereError('DX unit cool reheat part-load ratio calculation failed: part-load ratio limits '// &
                                   'exceeded, for unit = '//TRIM(CBVAV(CBVAVNum)%Name))
                    CALL ShowContinueError('Estimated part-load ratio = '//TRIM(RoundSigDigits(PartLoadFrac,3)))
                    CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation '// &
                                               'continues. Occurrence info: ')
                  ELSE
                    CALL ShowRecurringWarningErrorAtEnd(TRIM(CBVAV(CBVAVNum)%Name)// &
                                     ', Dehumidifying part-load ratio calculation failed for DX unit error continues.', &
                                        CBVAV(CBVAVNum)%DMDXIterationFailedIndex,PartLoadFrac,PartLoadFrac)
                  END IF
                END IF
              END IF
          END IF ! End if humidity ratio setpoint not met - CoolReheat humidity control

          IF(PartLoadFrac.GT.1.0d0) THEN
            PartLoadFrac = 1.0d0
          ELSEIF(PartLoadFrac < 0.0d0) THEN
            PartLoadFrac = 0.0d0
          END IF

      CASE DEFAULT
        CALL ShowFatalError('SimCBVAV System: Invalid DX Cooling Coil='//  &
                          TRIM(CBVAV(CBVAVNum)%DXCoolCoilType))

      END SELECT
    ELSE ! IF(OutdoorDryBulbTemp .GE. CBVAV(CBVAVNum)%MinOATCompressor)THEN
!     Simulate DX cooling coil with compressor off
      IF (CBVAV(CBVAVNum)%DXCoolCoilType_Num == CoilDX_CoolingHXAssisted) THEN
        CALL SimHXAssistedCoolingCoil(CBVAV(CBVAVNum)%DXCoolCoilName,FirstHVACIteration,Off,0.0d0,&
                                      CBVAV(CBVAVNum)%CoolCoilCompIndex, ContFanCycCoil, HXUnitEnable=HXUnitOn)
      ELSE IF(CBVAV(CBVAVNum)%DXCoolCoilType_Num == CoilDX_CoolingSingleSpeed)THEN
        CALL SimDXCoil(CBVAV(CBVAVNum)%DXCoolCoilName,Off,FirstHVACIteration, 0.0d0,CBVAV(CBVAVNum)%CoolCoilCompIndex,  &
           ContFanCycCoil, OnOffAirFlowRatio)
      ELSE IF(CBVAV(CBVAVNum)%DXCoolCoilType_Num == CoilDX_CoolingTwoStageWHumControl)THEN
        CALL SimDXCoilMultiMode(CBVAV(CBVAVNum)%DXCoolCoilName,Off,FirstHVACIteration, 0.0d0,0,CBVAV(CBVAVNum)%CoolCoilCompIndex, &
                                ContFanCycCoil)
      END IF
    END IF
    SaveCompressorPLR = DXCoilPartLoadRatio(CBVAV(CBVAVNum)%DXCoolCoilIndexNum)
! Simulate cooling coil with compressor off if zone requires heating
  ELSE ! HeatCoolMode == HeatingMode and no cooling is required, set PLR to 0
    IF (CBVAV(CBVAVNum)%DXCoolCoilType_Num == CoilDX_CoolingHXAssisted) THEN
      CALL SimHXAssistedCoolingCoil(CBVAV(CBVAVNum)%DXCoolCoilName,FirstHVACIteration,Off,0.0d0,CBVAV(CBVAVNum)%CoolCoilCompIndex, &
                                    ContFanCycCoil, HXUnitEnable=HXUnitOn)
    ELSE IF(CBVAV(CBVAVNum)%DXCoolCoilType_Num == CoilDX_CoolingSingleSpeed)THEN
      CALL SimDXCoil(CBVAV(CBVAVNum)%DXCoolCoilName,Off,FirstHVACIteration, 0.0d0,CBVAV(CBVAVNum)%CoolCoilCompIndex,  &
         ContFanCycCoil, OnOffAirFlowRatio)
    ELSE IF(CBVAV(CBVAVNum)%DXCoolCoilType_Num == CoilDX_CoolingTwoStageWHumControl)THEN
      CALL SimDXCoilMultiMode(CBVAV(CBVAVNum)%DXCoolCoilName,Off,FirstHVACIteration,0.0d0,0,CBVAV(CBVAVNum)%CoolCoilCompIndex, &
                              ContFanCycCoil)
    END IF
  END IF

! Simulate the heating coil based on coil type
  SELECT CASE(CBVAV(CBVAVNum)%HeatCoilType_Num)

  CASE(CoilDX_HeatingEmpirical)
!   Simulate DX heating coil if zone load is positive (heating load)
    IF (CBVAV(CBVAVNum)%HeatCoolMode == HeatingMode)THEN
      IF(OutdoorDryBulbTemp .GT. CBVAV(CBVAVNum)%MinOATCompressor)THEN
!       simulate the DX heating coil
        CALL SimDXCoil(CBVAV(CBVAVNum)%HeatCoilName,On,FirstHVACIteration, PartLoadFrac,CBVAV(CBVAVNum)%HeatCoilIndex,  &
           ContFanCycCoil, OnOffAirFlowRatio)
        IF(Node(CBVAV(CBVAVNum)%HeatingCoilOutletNode)%Temp .GT. CBVAV(CBVAVNum)%CoilTempSetpoint .AND. &
           Node(CBVAV(CBVAVNum)%HeatingCoilInletNode)%Temp .LT. CBVAV(CBVAVNum)%CoilTempSetpoint)THEN
            ! iterate to find PLR at CoilTempSetpoint
            Par(1) = REAL(CBVAV(CBVAVNum)%HeatCoilIndex,r64)
            Par(2) = MIN(CBVAV(CBVAVNum)%CoilTempSetpoint,CBVAV(CBVAVNum)%MaxLATHeating)
            Par(3) = OnOffAirFlowRatio
            CALL SolveRegulaFalsi(SmallTempDiff, MaxIte, SolFla, PartLoadFrac, DXHeatingCoilResidual, 0.0d0, 1.0d0, Par)
            CALL SimDXCoil(CBVAV(CBVAVNum)%HeatCoilName,On,FirstHVACIteration, PartLoadFrac,CBVAV(CBVAVNum)%HeatCoilIndex,  &
               ContFanCycCoil, OnOffAirFlowRatio)
            IF (SolFla == -1 .AND. .NOT. WarmupFlag) THEN
              CALL ShowWarningError('Iteration limit exceeded calculating DX unit part-load ratio, for unit = '// &
                                TRIM(CBVAV(CBVAVNum)%HeatCoilName))
              CALL ShowContinueError('Calculated part-load ratio = '//TRIM(RoundSigDigits(PartLoadFrac,3)))
              CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation continues.'// &
                                              ' Occurrence info: ')
            ELSE IF (SolFla == -2 .AND. .NOT. WarmupFlag) THEN
              CALL ShowSevereError('DX unit part-load ratio calculation failed: part-load ratio limits exceeded, for unit = '// &
                                 TRIM(CBVAV(CBVAVNum)%HeatCoilName))
              CALL ShowContinueErrorTimeStamp('A part-load ratio of '//TRIM(RoundSigDigits(PartLoadFrac,3))// &
                                              'will be used and the simulation continues. Occurrence info: ')
              CALL ShowContinueError('Please send this information to the EnergyPlus support group.')
            END IF
        END IF
      ELSE ! OAT .LT. MinOATCompressor
!       simulate DX heating coil with compressor off
        CALL SimDXCoil(CBVAV(CBVAVNum)%HeatCoilName,Off,FirstHVACIteration,0.0d0, CBVAV(CBVAVNum)%HeatCoilIndex,  &
                       ContFanCycCoil, OnOffAirFlowRatio)
      END IF
      SaveCompressorPLR = DXCoilPartLoadRatio(CBVAV(CBVAVNum)%DXHeatCoilIndexNum)
    ELSE ! HeatCoolMode = CoolingMode
!     simulate DX heating coil with compressor off when cooling load is required
      CALL SimDXCoil(CBVAV(CBVAVNum)%HeatCoilName,Off,FirstHVACIteration, 0.0d0,CBVAV(CBVAVNum)%HeatCoilIndex, &
                     ContFanCycCoil, OnOffAirFlowRatio)
    END IF
  CASE(Coil_HeatingGas, Coil_HeatingElectric, Coil_HeatingWater, Coil_HeatingSteam)  ! not a DX heating coil
    IF(CBVAV(CBVAVNum)%HeatCoolMode == HeatingMode)THEN
      CpAir = PsyCpAirFnWTdb(Node(CBVAV(CBVAVNum)%HeatingCoilInletNode)%HumRat,Node(CBVAV(CBVAVNum)%HeatingCoilInletNode)%Temp)
      QHeater = Node(CBVAV(CBVAVNum)%HeatingCoilInletNode)%MassFlowRate * CpAir * &
                  (CBVAV(CBVAVNum)%CoilTempSetpoint - Node(CBVAV(CBVAVNum)%HeatingCoilInletNode)%Temp)
    ELSE
      QHeater = 0.0d0
    END IF
    ! Added None DX heating coils calling point
    CALL CalcNonDXHeatingCoils(CBVAVNum,FirstHVACIteration,QHeater,CBVAV(CBVAVNum)%OpMode,QHeaterActual)
  CASE DEFAULT
        CALL ShowFatalError('SimCBVAV System: Invalid Heating Coil='//  &
                          TRIM(CBVAV(CBVAVNum)%HeatCoilType))

  END SELECT

  IF (CBVAV(CBVAVNum)%FanPlace .EQ. DrawThru)&
     CALL SimulateFanComponents(CBVAV(CBVAVNum)%FanName,FirstHVACIteration,CBVAV(CBVAVNum)%FanIndex,FanSpeedRatio)

  Node(OutletNode)%MassFlowRate =  (1.0d0 - ByPassDuctFlowFraction) * Node(CBVAV(CBVAVNum)%MixerInletAirNode)%MassFlowRate
  Node(OutletNode)%Temp         = Node(CBVAV(CBVAVNum)%SplitterOutletAirNode)%Temp
  Node(OutletNode)%HumRat       = Node(CBVAV(CBVAVNum)%SplitterOutletAirNode)%HumRat
  Node(OutletNode)%Quality      = Node(CBVAV(CBVAVNum)%SplitterOutletAirNode)%Quality
  Node(OutletNode)%Press        = Node(CBVAV(CBVAVNum)%SplitterOutletAirNode)%Press
  Node(OutletNode)%Enthalpy     = Node(CBVAV(CBVAVNum)%SplitterOutletAirNode)%Enthalpy
  Node(OutletNode)%Height       = Node(CBVAV(CBVAVNum)%SplitterOutletAirNode)%Height

  CBVAV(CBVAVNum)%BypassMassFlowRate = ByPassDuctFlowFraction * Node(CBVAV(CBVAVNum)%MixerInletAirNode)%MassFlowRate

! calculate sensible load met using delta enthalpy at a constant (minimum) humidity ratio)
  MinHumRat = MIN(Node(InletNode)%HumRat,Node(OutletNode)%HumRat)
  LoadMet   = Node(OutletNode)%MassFlowRate * &
             (PsyHFnTdbW(Node(OutletNode)%Temp,MinHumRat) - PsyHFnTdbW(Node(InletNode)%Temp,MinHumRat))

RETURN
END SUBROUTINE CalcCBVAV

SUBROUTINE GetZoneLoads(CBVAVNum, QZoneReq)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2006
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine is used to poll the thermostats in each zone and determine the
          ! mode of operation, either cooling, heating, or none.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DataZoneEnergyDemands,      ONLY: ZoneSysEnergyDemand, CurDeadBandOrSetback

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT (IN)    :: CBVAVNum            ! Index to CBVAV unit being simulated
  REAL(r64),    INTENT (INOUT) :: QZoneReq           ! Total zone load served by this air loop

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER             :: ZoneNum          ! Zone number of controlled zone in CBVAV loop
  REAL(r64)           :: QZoneReqCool     ! Total cooling load in all controlled zones [W]
  REAL(r64)           :: QZoneReqHeat     ! Total heating load in all controlled zones [W]
  REAL(r64)           :: ZoneLoad         ! Total load in controlled zone [W]
  REAL(r64)           :: ZoneLoadToCoolSPSequenced
  REAL(r64)           :: ZoneLoadToHeatSPSequenced

  QZoneReqCool = 0.0d0
  QZoneReqHeat = 0.0d0
  CBVAV(CBVAVNum)%NumZonesCooled = 0
  CBVAV(CBVAVNum)%NumZonesHeated = 0
  CBVAV(CBVAVNum)%HeatCoolMode = 0

  DO ZoneNum = 1, CBVAV(CBVAVNum)%NumControlledZones
    IF ((CBVAV(CBVAVNum)%ZoneSequenceCoolingNum(ZoneNum) > 0) .AND. (CBVAV(CBVAVNum)%ZoneSequenceHeatingNum(ZoneNum) > 0)) THEN
      ZoneLoadToCoolSPSequenced = ZoneSysEnergyDemand(CBVAV(CBVAVNum)%ControlledZoneNum(ZoneNum))%&
                  SequencedOutputRequiredToCoolingSP(CBVAV(CBVAVNum)%ZoneSequenceCoolingNum(ZoneNum))
      ZoneLoadToHeatSPSequenced = ZoneSysEnergyDemand(CBVAV(CBVAVNum)%ControlledZoneNum(ZoneNum))%&
                  SequencedOutputRequiredToHeatingSP(CBVAV(CBVAVNum)%ZoneSequenceHeatingNum(ZoneNum))
      IF (ZoneLoadToHeatSPSequenced > 0.d0 .AND. ZoneLoadToCoolSPSequenced > 0.d0) THEN
        ZoneLoad = ZoneLoadToHeatSPSequenced
      ELSEIF (ZoneLoadToHeatSPSequenced < 0.d0 .AND. ZoneLoadToCoolSPSequenced < 0.d0) THEN
        ZoneLoad = ZoneLoadToCoolSPSequenced
      ELSEIF (ZoneLoadToHeatSPSequenced <= 0.d0 .AND. ZoneLoadToCoolSPSequenced >= 0.d0) THEN
        ZoneLoad = 0.d0
      ENDIF
    ELSE
      ZoneLoad= ZoneSysEnergyDemand(CBVAV(CBVAVNum)%ControlledZoneNum(ZoneNum))%RemainingOutputRequired
    ENDIF


    IF(.NOT. CurDeadBandOrSetback(ZoneNum))THEN
      IF(ZoneLoad .GT. 0.0d0 .AND. ABS(ZoneLoad) .GT. SmallLoad)THEN
        QZoneReqHeat = QZoneReqHeat + ZoneLoad
        CBVAV(CBVAVNum)%NumZonesHeated = CBVAV(CBVAVNum)%NumZonesHeated + 1
      ELSE IF(ZoneLoad .LT. 0.0d0 .AND. ABS(ZoneLoad) .GT. SmallLoad)THEN
        QZoneReqCool = QZoneReqCool + ZoneLoad
        CBVAV(CBVAVNum)%NumZonesCooled = CBVAV(CBVAVNum)%NumZonesCooled + 1
      END IF
    END IF
  END DO

  SELECT CASE(CBVAV(CBVAVNum)%PriorityControl)
    CASE (CoolingPriority)
      IF(QZoneReqCool .LT. 0.0d0)THEN
        QZoneReq = QZoneReqCool
        CBVAV(CBVAVNum)%HeatCoolMode = CoolingMode
      ELSE IF(QZoneReqHeat .GT. 0.0d0)THEN
        QZoneReq = QZoneReqHeat
        CBVAV(CBVAVNum)%HeatCoolMode = HeatingMode
      ELSE
        QZoneReq = 0.0d0
      END IF
    CASE (HeatingPriority)
      IF(QZoneReqHeat .GT. 0.0d0)THEN
        QZoneReq = QZoneReqHeat
        CBVAV(CBVAVNum)%HeatCoolMode = HeatingMode
      ELSE IF(QZoneReqCool .LT. 0.0d0)THEN
        QZoneReq = QZoneReqCool
        CBVAV(CBVAVNum)%HeatCoolMode = CoolingMode
      ELSE
        QZoneReq = 0.0d0
      END IF
    CASE (ZonePriority)
      IF(CBVAV(CBVAVNum)%NumZonesHeated .GT. CBVAV(CBVAVNum)%NumZonesCooled)THEN
        IF(QZoneReqHeat .GT. 0.0d0)THEN
          QZoneReq = QZoneReqHeat
          CBVAV(CBVAVNum)%HeatCoolMode = HeatingMode
        ELSE IF(QZoneReqCool .LT. 0.0d0)THEN
          QZoneReq = QZoneReqCool
          CBVAV(CBVAVNum)%HeatCoolMode = CoolingMode
        ELSE
          QZoneReq = 0.0d0
        END IF
      ELSE IF(CBVAV(CBVAVNum)%NumZonesCooled .GT. CBVAV(CBVAVNum)%NumZonesHeated)THEN
        IF(QZoneReqCool .LT. 0.0d0)THEN
          QZoneReq = QZoneReqCool
          CBVAV(CBVAVNum)%HeatCoolMode = CoolingMode
        ELSE IF(QZoneReqHeat .GT. 0.0d0)THEN
          QZoneReq = QZoneReqHeat
          CBVAV(CBVAVNum)%HeatCoolMode = HeatingMode
        ELSE
          QZoneReq = 0.0d0
        END IF
      ELSE
        IF(ABS(QZoneReqCool) .GT. ABS(QZoneReqHeat) .AND. QZoneReqCool .NE. 0.0d0)THEN
          QZoneReq = QZoneReqCool
          CBVAV(CBVAVNum)%HeatCoolMode = CoolingMode
        ELSE IF(ABS(QZoneReqCool) .LT. ABS(QZoneReqHeat) .AND. QZoneReqHeat .NE. 0.0d0)THEN
          QZoneReq = QZoneReqHeat
          CBVAV(CBVAVNum)%HeatCoolMode = HeatingMode
        ELSE IF(ABS(QZoneReqCool) .EQ. ABS(QZoneReqHeat) .AND. QZoneReqCool .NE. 0.0d0)THEN
          QZoneReq = QZoneReqCool
          CBVAV(CBVAVNum)%HeatCoolMode = CoolingMode
        ELSE
          QZoneReq = 0.0d0
        END IF
      END IF
  END SELECT

 RETURN
END SUBROUTINE GetZoneLoads

REAL(r64) FUNCTION CalcSetpointTempTarget(CBVAVNumber)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   August 2006
          !       MODIFIED       na
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          !  Calculate outlet air node temperature setpoint

          ! METHODOLOGY EMPLOYED:
          !  Calculate an outlet temperature to satisfy zone loads. This temperature is calculated
          !  based on 1 zone's VAV box fully opened. The other VAV boxes are partially open (modulated).

          ! REFERENCES:
          !  na

          ! USE STATEMENTS:
  USE Psychrometrics,        ONLY: PsyCpAirFnWTdb
  USE DataZoneEnergyDemands, ONLY: ZoneSysEnergyDemand

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN) :: CBVAVNumber      ! Index to changeover-bypass VAV system

          ! FUNCTION PARAMETER DEFINITIONS:
          !  na

          ! INTERFACE BLOCK SPECIFICATIONS:
          !  na

          ! DERIVED TYPE DEFINITIONS:
          !  na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:

  INTEGER :: OutletNode          ! Outlet node of CBVAV system
  INTEGER :: ZoneNum             ! Index to controlled zone
  INTEGER :: ZoneNodeNum         ! Zone node number of controlled zone
  INTEGER :: BoxOutletNodeNum    ! CBVAV box outlet node (zone supply inlet node)
  REAL(r64)    :: DXCoolCoilInletTemp ! Air temperature of CBVAV DX cooling coil air inlet node [C]
  REAL(r64)    :: OutAirTemp          ! Outlet air temperature of CBVAV system [C]
  REAL(r64)    :: OutAirHumRat        ! Outlet air humidity ratio of CBVAV system [C]
  REAL(r64)    :: ZoneLoad            ! Zone load sensed by thermostat [W]
  REAL(r64)    :: CpSupplyAir         ! Specific heat of CBVAV system outlet air [J/kg-K]
  REAL(r64)    :: QToCoolSetPt        ! Zone load to cooling setpoint [W]
  REAL(r64)    :: QToHeatSetPt        ! Zone load to heating setpoint [W]
  REAL(r64)    :: SupplyAirTemp       ! Supply air temperature required to meet load [C]
  REAL(r64)    :: TSupplyToHeatSetPtMax ! Maximum of the supply air temperatures required to reach the heating setpoint [C]
  REAL(r64)    :: TSupplyToCoolSetPtMin ! Minimum of the supply air temperatures required to reach the cooling setpoint [C]
  REAL(r64)    :: SupplyAirTempToHeatSetPt ! Supply air temperature required to reach the heating setpoint [C]
  REAL(r64)    :: SupplyAirTempToCoolSetPt ! Supply air temperature required to reach the cooling setpoint [C]

  DXCoolCoilInletTemp = Node(CBVAV(CBVAVNumber)%DXCoilInletNode)%Temp
  OutAirTemp = Node(CBVAV(CBVAVNumber)%AirOutNode)%Temp
  OutAirHumRat = Node(CBVAV(CBVAVNumber)%AirOutNode)%HumRat

  IF(CBVAV(CBVAVNumber)%HeatCoolMode == CoolingMode)THEN ! Cooling required
    CalcSetpointTempTarget    = 99999.0d0
  ELSE IF(CBVAV(CBVAVNumber)%HeatCoolMode == HeatingMode)THEN ! Heating required
    CalcSetpointTempTarget    = -99999.0d0
  END IF
  TSupplyToHeatSetPtMax    = -99999.0d0
  TSupplyToCoolSetPtMin    = 99999.0d0

    OutletNode         = CBVAV(CBVAVNumber)%AirOutNode
    DO ZoneNum         = 1, CBVAV(CBVAVNumber)%NumControlledZones
      ZoneNodeNum      = CBVAV(CBVAVNumber)%ActualZoneNodeNum(ZoneNum)
      BoxOutletNodeNum = CBVAV(CBVAVNumber)%CBVAVBoxOutletNode(ZoneNum)
      IF ((CBVAV(CBVAVNumber)%ZoneSequenceCoolingNum(ZoneNum) > 0) .AND. &
          (CBVAV(CBVAVNumber)%ZoneSequenceHeatingNum(ZoneNum) > 0)) THEN
        QToCoolSetPt = ZoneSysEnergyDemand(CBVAV(CBVAVNumber)%ControlledZoneNum(ZoneNum))%&
                    SequencedOutputRequiredToCoolingSP(CBVAV(CBVAVNumber)%ZoneSequenceCoolingNum(ZoneNum))
        QToHeatSetPt = ZoneSysEnergyDemand(CBVAV(CBVAVNumber)%ControlledZoneNum(ZoneNum))%&
                    SequencedOutputRequiredToHeatingSP(CBVAV(CBVAVNumber)%ZoneSequenceHeatingNum(ZoneNum))
        IF (QToHeatSetPt > 0.d0 .AND. QToCoolSetPt > 0.d0) THEN
          ZoneLoad = QToHeatSetPt
        ELSEIF (QToHeatSetPt < 0.d0 .AND. QToCoolSetPt < 0.d0) THEN
          ZoneLoad = QToCoolSetPt
        ELSEIF (QToHeatSetPt <= 0.d0 .AND. QToCoolSetPt >= 0.d0) THEN
          ZoneLoad = 0.d0
        ENDIF
      ELSE
        ZoneLoad     = ZoneSysEnergyDemand(CBVAV(CBVAVNumber)%ControlledZoneNum(ZoneNum))%RemainingOutputRequired
        QToCoolSetPt = ZoneSysEnergyDemand(CBVAV(CBVAVNumber)%ControlledZoneNum(ZoneNum))%OutputRequiredToCoolingSP
        QToHeatSetPt = ZoneSysEnergyDemand(CBVAV(CBVAVNumber)%ControlledZoneNum(ZoneNum))%OutputRequiredToHeatingSP
      ENDIF

      CpSupplyAir      = PsyCpAirFnWTdb(OutAirHumRat,OutAirTemp)

!     Find the supply air temperature that will force the box to full flow
      IF(BoxOutletNodeNum .GT. 0)THEN
        IF(CpSupplyAir*Node(BoxOutletNodeNum)%MassFlowRateMax .EQ. 0.0d0)THEN
          SupplyAirTemp = Node(ZoneNodeNum)%Temp
        ELSE
!         The target supply air temperature is slightly
          SupplyAirTemp = Node(ZoneNodeNum)%Temp + ZoneLoad/(CpSupplyAir*Node(BoxOutletNodeNum)%MassFlowRateMax)
        END IF
      ELSE
        SupplyAirTemp = Node(ZoneNodeNum)%Temp
      END IF

!     Save the MIN (cooling) or MAX (heating) temperature for coil control
!     One box will always operate at maximum damper position minimizing overall system energy use
      IF(CBVAV(CBVAVNumber)%HeatCoolMode == CoolingMode)THEN
        CalcSetpointTempTarget = MIN(SupplyAirTemp,CalcSetpointTempTarget)
      ELSE IF(CBVAV(CBVAVNumber)%HeatCoolMode == HeatingMode)THEN
        CalcSetpointTempTarget = MAX(SupplyAirTemp,CalcSetpointTempTarget)
      ELSE
!       Should use CpAirAtCoolSetpoint or CpAirAtHeatSetpoint here?
!       If so, use ZoneThermostatSetPointLo(ZoneNum) and ZoneThermostatSetPointHi(ZoneNum)
!       along with the zone humidity ratio
        IF(CpSupplyAir*Node(BoxOutletNodeNum)%MassFlowRateMax .EQ. 0.0d0)THEN
          SupplyAirTempToHeatSetPt = Node(ZoneNodeNum)%Temp
          SupplyAirTempToCoolSetPt = Node(ZoneNodeNum)%Temp
        ELSE
          SupplyAirTempToHeatSetPt = Node(ZoneNodeNum)%Temp + QToHeatSetPt/(CpSupplyAir*Node(BoxOutletNodeNum)%MassFlowRateMax)
          SupplyAirTempToCoolSetPt = Node(ZoneNodeNum)%Temp + QToCoolSetPt/(CpSupplyAir*Node(BoxOutletNodeNum)%MassFlowRateMax)
        END IF
        TSupplyToHeatSetPtMax = MAX(SupplyAirTempToHeatSetPt, TSupplyToHeatSetPtMax)
        TSupplyToCoolSetPtMin = MIN(SupplyAirTempToCoolSetPt, TSupplyToCoolSetPtMin)
      END IF

    END DO

!   Account for floating condition where cooling/heating is required to avoid overshooting setpoint
    IF(CBVAV(CBVAVNumber)%HeatCoolMode == 0 .AND. CBVAV(CBVAVNumber)%OpMode == ContFanCycCoil)THEN
      IF(OutAirTemp .GT. TSupplyToCoolSetPtMin)THEN
        CalcSetpointTempTarget          = TSupplyToCoolSetPtMin
        CBVAV(CBVAVNumber)%HeatCoolMode = CoolingMode
      ELSEIF(OutAirTemp .LT. TSupplyToHeatSetPtMax)THEN
        CalcSetpointTempTarget          = TSupplyToHeatSetPtMax
        CBVAV(CBVAVNumber)%HeatCoolMode = HeatingMode
      ELSE
        CalcSetpointTempTarget = OutAirTemp
      END IF
!   Reset setpoint to inlet air temp if unit is OFF and in cycling fan mode
    ELSE IF(CBVAV(CBVAVNumber)%HeatCoolMode == 0 .AND. CBVAV(CBVAVNumber)%OpMode == CycFanCycCoil)THEN
      CalcSetpointTempTarget = Node(CBVAV(CBVAVNumber)%AirInNode)%Temp
!   Reset cooling/heating mode to OFF if mixed air inlet temperature is below/above setpoint temperature.
!   HeatCoolMode = 0 for OFF, 1 for cooling, 2 for heating
    ELSE IF(CBVAV(CBVAVNumber)%HeatCoolMode == CoolingMode .AND. DXCoolCoilInletTemp .LT. CalcSetpointTempTarget)THEN
      CalcSetpointTempTarget = DXCoolCoilInletTemp
      CBVAV(CBVAVNumber)%HeatCoolMode = 0
    ELSE IF(CBVAV(CBVAVNumber)%HeatCoolMode == HeatingMode .AND. DXCoolCoilInletTemp .GT. CalcSetpointTempTarget)THEN
      CalcSetpointTempTarget = DXCoolCoilInletTemp
      CBVAV(CBVAVNumber)%HeatCoolMode = 0
    END IF

!   Limit outlet node temperature to MAX/MIN specified in input
    IF(CalcSetpointTempTarget .LT. CBVAV(CBVAVNumber)%MinLATCooling) CalcSetpointTempTarget = CBVAV(CBVAVNumber)%MinLATCooling
    IF(CalcSetpointTempTarget .GT. CBVAV(CBVAVNumber)%MaxLATHeating) CalcSetpointTempTarget = CBVAV(CBVAVNumber)%MaxLATHeating

  RETURN

END FUNCTION CalcSetpointTempTarget

FUNCTION DOE2DXCoilResidual(PartLoadFrac, Par) RESULT (Residuum)
          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   June 2006
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls CalcDoe2DXCoil to get outlet temperature at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils, ONLY: DXCoilOutletTemp, CalcDoe2DXCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadFrac               ! Compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! Par(1) = DX coil number
                                                    ! Par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum                   ! Residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER :: CoilIndex              ! Index of this coil
  REAL(r64)    :: OutletAirTemp          ! Outlet air temperature [C]
  REAL(r64)    :: OnOffAirFlowFrac       ! Ratio of compressor ON to compressor OFF air mass flow rate

  CoilIndex        = INT(Par(1))
  OnOffAirFlowFrac = Par(3)

  CALL CalcDoe2DXCoil(CoilIndex,On,.FALSE., PartLoadFrac, ContFanCycCoil, OnOffAirFlowRatio=OnOffAirFlowFrac)

  OutletAirTemp = DXCoilOutletTemp(CoilIndex)
  Residuum      = Par(2) - OutletAirTemp

  RETURN
END FUNCTION DOE2DXCoilResidual

FUNCTION HXAssistDXCoilResidual(PartLoadFrac, Par) RESULT (Residuum)
          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   June 2006
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired DX coil outlet temp - actual DX coil outlet temp)
          ! HX Assisted DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls CalcDoe2DXCoil to get outlet temperature at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE HVACHXAssistedCoolingCoil, ONLY: SimHXAssistedCoolingCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadFrac               ! Compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! Par(1) = DX coil number
                                                    ! Par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum                   ! Residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER :: CoilIndex        ! Index of this coil
  REAL(r64)    :: OutletAirTemp    ! Outlet air temperature of DX cooling coil [C]
  REAL(r64)    :: OnOffAirFlowFrac ! Air flow fraction
  INTEGER :: CBVAVNumTemp      ! Local index to changeover-bypass VAV system
  LOGICAL :: FirstHVACIter    ! Local Flag denoting the first pass on the air loop simulation
  LOGICAL :: HXUnitOn         ! flag to enable heat exchanger

  CoilIndex        = INT(Par(1))
  OnOffAirFlowFrac = Par(3)
  CBVAVNumTemp      = INT(Par(4))
  IF(Par(5) .EQ. 1.0d0)THEN
    FirstHVACIter = .TRUE.
  ELSE
    FirstHVACIter = .FALSE.
  END IF
  IF(Par(6) .EQ. 1.0d0)THEN
    HXUnitOn = .TRUE.
  ELSE
    HXUnitOn = .FALSE.
  END IF

  CALL SimHXAssistedCoolingCoil(CBVAV(CBVAVNumTemp)%DXCoolCoilName,FirstHVACIter,On,PartLoadFrac, CoilIndex, &
                                ContFanCycCoil, HXUnitEnable=HXUnitOn)

  OutletAirTemp = Node(CBVAV(CBVAVNumTemp)%DXCoilOutletNode)%Temp
  Residuum      = Par(2) - OutletAirTemp

  RETURN
END FUNCTION HXAssistDXCoilResidual

FUNCTION DXHeatingCoilResidual(PartLoadFrac, Par) RESULT (Residuum)
          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   June 2006
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls CalcDoe2DXCoil to get outlet temperature at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils, ONLY: DXCoilOutletTemp, CalcDXHeatingCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadFrac               ! Compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! Par(1) = DX coil number
                                                    ! Par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum                   ! Residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER :: CoilIndex        ! Index of this coil
  REAL(r64)    :: OutletAirTemp    ! Outlet air temperature [C]
  REAL(r64)    :: OnOffAirFlowFrac ! Ratio of compressor ON to compressor OFF air mass flow rate

  CoilIndex        = INT(Par(1))
  OnOffAirFlowFrac = Par(3)

  CALL CalcDXHeatingCoil(CoilIndex,PartLoadFrac,ContFanCycCoil,OnOffAirFlowFrac)

  OutletAirTemp = DXCoilOutletTemp(CoilIndex)
  Residuum      = Par(2) - OutletAirTemp

  RETURN
END FUNCTION DXHeatingCoilResidual

FUNCTION MultiModeDXCoilResidual(PartLoadRatio, Par) RESULT (Residuum)
          ! FUNCTION INFORMATION:
          !       AUTHOR         M. J. Witte, GARD Analytics, Inc.
          !       DATE WRITTEN   February 2005
          !                      (based on DOE2DXCoilResidual by Richard Raustad, FSEC)
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimDXCoilMultiMode to get outlet temperature at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils, ONLY: DXCoilOutletTemp, SimDXCoilMultiMode

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet temperature [C]
                                                    ! par(3) = dehumidification mode (0=normal, 1=enhanced)
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER :: CoilIndex       ! index of this coil
  REAL(r64) ::    OutletAirTemp   ! outlet air temperature [C]
  INTEGER :: DehumidMode     ! dehumidification mode (par3)
  INTEGER :: FanOpMode       ! allows parent object to control fan mode

  CoilIndex   = INT(Par(1))
  DehumidMode = INT(Par(3))
  FanOpMode = 2
  CALL SimDXCoilMultiMode('',On,.FALSE.,PartLoadRatio,DehumidMode,CoilIndex, FanOpMode)
  OutletAirTemp = DXCoilOutletTemp(CoilIndex)
  Residuum = Par(2) - OutletAirTemp

  RETURN
END FUNCTION MultiModeDXCoilResidual

SUBROUTINE SetAverageAirFlow(CBVAVNum,OnOffAirFlowRatio, FirstHVACIteration)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2006
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! Set the average air mass flow rates for this time step
          ! Set OnOffAirFlowRatio to be used by DX coils

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE MixedAir,              ONLY: SimOAMixer
  USE Psychrometrics,        ONLY: PsyCpAirFnWTdb
  USE ScheduleManager,       ONLY: GetCurrentScheduleValue
  USE DataZoneEnergyDemands, ONLY: ZoneSysEnergyDemand

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT (IN)    :: CBVAVNum            ! Index to CBVAV system
  REAL(r64)   , INTENT (INOUT) :: OnOffAirFlowRatio  ! Ratio of compressor ON airflow to average airflow over timestep
  LOGICAL, INTENT (IN)    :: FirstHVACIteration ! Flag denoting the first pass on the air loop simulation

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER             :: InletNode            ! Inlet node number for CBVAVNum
  INTEGER             :: OutletNode           ! Outlet node number for CBVAVNum
  INTEGER             :: MixerMixedAirNode    ! Mixed air node number in OA mixer
  INTEGER             :: MixerOutsideAirNode  ! Outside air node number in OA mixer
  INTEGER             :: MixerReliefAirNode   ! Relief air node number in OA mixer
  INTEGER             :: MixerInletAirNode   ! Mixed air node number in OA mixer
  REAL(r64)           :: AverageUnitMassFlow  ! Average system air mass flow rate over time step [kg/s]
  REAL(r64)           :: AverageOAMassFlow    ! Average outdoor air mass flow rate over time step [kg/s]
  REAL(r64)           :: CpSupplyAir          ! Specific heat of outlet air [J/kg-K]
  REAL(r64)           :: CpZoneAir            ! Specific heat of zone air [J/kg-K]
  REAL(r64)           :: DeltaCpTemp          ! Temperature difference from supply air to zone air [C]
  REAL(r64)           :: ZoneMassFlow         ! Zone mass flow rate required to meet zone load [kg/s]
  REAL(r64)           :: SystemMassFlow       ! System mass flow rate required for all zones [kg/s]
  INTEGER             :: ZoneNum              ! Index to zone
  REAL(r64)           :: ZoneLoad             ! Zone load calculated by ZoneTempPredictor [W]
  REAL(r64)           :: QToHeatSetPt         ! Load to heating setpoint [W]
  REAL(r64)           :: QToCoolSetPt         ! Load to cooling setpoint [W]
  INTEGER             :: ZoneNodeNum          ! Actual zone number
  INTEGER             :: BoxOutletNodeNum     ! Zone supply air inlet node number

  InletNode           = CBVAV(CBVAVNum)%AirInNode
  OutletNode          = CBVAV(CBVAVNum)%AirOutNode
  MixerMixedAirNode   = CBVAV(CBVAVNum)%MixerMixedAirNode
  MixerOutsideAirNode = CBVAV(CBVAVNum)%MixerOutsideAirNode
  MixerReliefAirNode  = CBVAV(CBVAVNum)%MixerReliefAirNode
  MixerInletAirNode   = CBVAV(CBVAVNum)%MixerInletAirNode

  SystemMassFlow      = 0.0d0
  CpSupplyAir         = PsyCpAirFnWTdb(Node(OutletNode)%HumRat,Node(OutletNode)%Temp)
! Determine zone air flow
  DO ZoneNum = 1, CBVAV(CBVAVNum)%NumControlledZones
    ZoneNodeNum       = CBVAV(CBVAVNum)%ActualZoneNodeNum(ZoneNum)
    BoxOutletNodeNum  = CBVAV(CBVAVNum)%CBVAVBoxOutletNode(ZoneNum)
    IF ((CBVAV(CBVAVNum)%ZoneSequenceCoolingNum(ZoneNum) > 0) .AND. (CBVAV(CBVAVNum)%ZoneSequenceHeatingNum(ZoneNum) > 0)) THEN
      QToCoolSetPt = ZoneSysEnergyDemand(CBVAV(CBVAVNum)%ControlledZoneNum(ZoneNum))%&
                  SequencedOutputRequiredToCoolingSP(CBVAV(CBVAVNum)%ZoneSequenceCoolingNum(ZoneNum))
      QToHeatSetPt = ZoneSysEnergyDemand(CBVAV(CBVAVNum)%ControlledZoneNum(ZoneNum))%&
                  SequencedOutputRequiredToHeatingSP(CBVAV(CBVAVNum)%ZoneSequenceHeatingNum(ZoneNum))
      IF (QToHeatSetPt > 0.d0 .AND. QToCoolSetPt > 0.d0) THEN
        ZoneLoad = QToHeatSetPt
      ELSEIF (QToHeatSetPt < 0.d0 .AND. QToCoolSetPt < 0.d0) THEN
        ZoneLoad = QToCoolSetPt
      ELSEIF (QToHeatSetPt <= 0.d0 .AND. QToCoolSetPt >= 0.d0) THEN
        ZoneLoad = 0.d0
      ENDIF
    ELSE
      ZoneLoad     = ZoneSysEnergyDemand(CBVAV(CBVAVNum)%ControlledZoneNum(ZoneNum))%RemainingOutputRequired
      QToHeatSetPt = ZoneSysEnergyDemand(CBVAV(CBVAVNum)%ControlledZoneNum(ZoneNum))%OutputRequiredToHeatingSP
    ENDIF
    CpZoneAir         = PsyCpAirFnWTdb(Node(ZoneNodeNum)%HumRat,Node(ZoneNodeNum)%Temp)
    DeltaCpTemp       = CpSupplyAir*Node(OutletNode)%Temp - CpZoneAir*Node(ZoneNodeNum)%Temp

    !Need to check DeltaCpTemp and ensure that it is not zero
    IF(DeltaCpTemp .NE. 0.0d0) THEN ! .AND. .NOT. CurDeadBandOrSetback(ZoneNum))THEN
      ZoneMassFlow    = ZoneLoad/DeltaCpTemp
    ELSE
!     reset to 0 so we don't add in the last zone's mass flow rate
      ZoneMassFlow    = 0.0d0
    END IF
    SystemMassFlow    = SystemMassFlow + &
                        MAX(Node(BoxOutletNodeNum)%MassFlowRateMin,MIN(ZoneMassFlow,Node(BoxOutletNodeNum)%MassFlowRateMax))
  END DO

  AverageUnitMassFlow      = CompOnMassFlow
  AverageOAMassFlow        = OACompOnMassFlow
  FanSpeedRatio            = CompOnFlowRatio

  Node(MixerInletAirNode) = Node(InletNode)

  Node(MixerMixedAirNode)%MassFlowRateMin          = 0.0d0

  IF (GetCurrentScheduleValue(CBVAV(CBVAVNum)%SchedPtr) .EQ. 0.0d0 .OR. AverageUnitMassFlow .EQ. 0.0d0) THEN
    Node(InletNode)%MassFlowRate                   = 0.0d0
    Node(MixerOutsideAirNode)%MassFlowRate         = 0.0d0
    Node(MixerReliefAirNode)%MassFlowRate          = 0.0d0
    OnOffAirFlowRatio                              = 0.0d0
    ByPassDuctFlowFraction                         = 0.0d0
  ELSE
    Node(MixerInletAirNode)%MassFlowRate           = AverageUnitMassFlow
    Node(MixerOutsideAirNode)%MassFlowRate         = AverageOAMassFlow
    Node(MixerReliefAirNode)%MassFlowRate          = AverageOAMassFlow
    IF (FirstHVACIteration) THEN
      OnOffAirFlowRatio                            = 1.0d0
      ByPassDuctFlowFraction                       = 0.0d0
    ELSE
      OnOffAirFlowRatio                            = 1.0d0
      ByPassDuctFlowFraction = MAX(0.0d0,1.0d0 - (Node(InletNode)%MassFlowRate/AverageUnitMassFlow))
    END IF
  END IF

  RETURN
END SUBROUTINE SetAverageAirFlow

SUBROUTINE ReportCBVAV(CBVAVNum)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2006
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! Fills some of the report variables for the changeover-bypass VAV system

          ! METHODOLOGY EMPLOYED:
          ! NA

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DataHVACGlobals, ONLY: TimeStepSys

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT (IN) :: CBVAVNum   ! Index of the current CBVAV unit being simulated

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  REAL(r64) :: ReportingConstant

          ! FLOW
  ReportingConstant = TimeStepSys*SecInHour

  CBVAV(CBVAVNum)%TotCoolEnergy   = CBVAV(CBVAVNum)%TotCoolEnergyRate  * ReportingConstant
  CBVAV(CBVAVNum)%TotHeatEnergy   = CBVAV(CBVAVNum)%TotHeatEnergyRate  * ReportingConstant
  CBVAV(CBVAVNum)%SensCoolEnergy  = CBVAV(CBVAVNum)%SensCoolEnergyRate * ReportingConstant
  CBVAV(CBVAVNum)%SensHeatEnergy  = CBVAV(CBVAVNum)%SensHeatEnergyRate * ReportingConstant
  CBVAV(CBVAVNum)%LatCoolEnergy   = CBVAV(CBVAVNum)%LatCoolEnergyRate  * ReportingConstant
  CBVAV(CBVAVNum)%LatHeatEnergy   = CBVAV(CBVAVNum)%LatHeatEnergyRate  * ReportingConstant
  CBVAV(CBVAVNum)%ElecConsumption = CBVAV(CBVAVNum)%ElecPower          * ReportingConstant

  RETURN
END SUBROUTINE ReportCBVAV

SUBROUTINE CalcNonDXHeatingCoils(CBVAVNum,FirstHVACIteration,HeatCoilLoad,FanMode,HeatCoilLoadmet)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Bereket Nigusse, FSEC/UCF
          !       DATE WRITTEN   January 2012
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine simulates the four non dx heating coil types: Gas, Electric, hot water and steam.

          ! METHODOLOGY EMPLOYED:
          ! Simply calls the different heating coil component.  The hot water flow rate matching the coil load
          ! is calculated iteratively.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:

  USE HeatingCoils,              ONLY: SimulateHeatingCoilComponents
  USE WaterCoils,                ONLY: SimulateWaterCoilComponents
  USE SteamCoils,                ONLY: SimulateSteamCoilComponents
  USE PlantUtilities,            ONLY: SetComponentFlowRate
  USE General,                   ONLY: SolveRegulaFalsi,RoundSigDigits
  USE DataHVACGlobals,           ONLY: SmallLoad

  IMPLICIT NONE     ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER,      INTENT(IN)    :: CBVAVNum                  ! Changeover bypass VAV unit index
  LOGICAL,      INTENT(IN)    :: FirstHVACIteration        ! flag for first HVAC iteration in the time step
  REAL(r64),    INTENT(INOUT) :: HeatCoilLoad              ! heating coil load to be met (Watts)
  REAL(r64),    INTENT(OUT)   :: HeatCoilLoadmet           ! coil heating load met
  INTEGER,      INTENT(IN)    :: FanMode                   ! fan operation mode

          ! SUBROUTINE PARAMETER DEFINITIONS:
  REAL(r64), PARAMETER :: ErrTolerance = 0.001d0    ! convergence limit for hotwater coil
  INTEGER, PARAMETER :: SolveMaxIter=50

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  REAL(r64)      :: QCoilActual       ! actual heating load met
  REAL(r64)      :: mdot              ! heating coil steam or hot water mass flow rate
  REAL(r64)      :: MinWaterFlow      ! minimum water mass flow rate
  REAL(r64)      :: MaxHotWaterFlow   ! maximum hot water mass flow rate, kg/s
  REAL(r64)      :: HotWaterMdot      ! actual hot water mass flow rate
  REAL(r64), DIMENSION(3) :: Par      !
  INTEGER        :: SolFlag           ! error flag

  QCoilActual=0.0d0
  IF (HeatCoilLoad > SmallLoad) THEN
     Select Case (CBVAV(CBVAVNum)%HeatCoilType_Num)
        Case (Coil_HeatingGas, Coil_HeatingElectric)
          CALL SimulateHeatingCoilComponents(CBVAV(CBVAVNum)%HeatCoilName,FirstHVACIteration, &
                                             HeatCoilLoad, CBVAV(CBVAVNum)%HeatCoilIndex, &
                                             QCoilActual, .TRUE., FanMode)
        Case (Coil_HeatingWater)
          ! simulate the heating coil at maximum hot water flow rate
          MaxHotWaterFlow = CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow
          Call SetComponentFlowRate(MaxHotWaterFlow , &
                                    CBVAV(CBVAVNum)%CoilControlNode, &
                                    CBVAV(CBVAVNum)%CoilOutletNode, &
                                    CBVAV(CBVAVNum)%LoopNum, &
                                    CBVAV(CBVAVNum)%LoopSide, &
                                    CBVAV(CBVAVNum)%BranchNum, &
                                    CBVAV(CBVAVNum)%CompNum)
          CALL SimulateWaterCoilComponents(CBVAV(CBVAVNum)%HeatCoilName,FirstHVACIteration, &
                                           CBVAV(CBVAVNum)%HeatCoilIndex, QCoilActual, FanMode)
          IF ( QCoilActual > (HeatCoilLoad + SmallLoad)) Then
              ! control water flow to obtain output matching HeatCoilLoad
              SolFlag = 0
              MinWaterFlow = 0.0d0
              Par(1) = REAL(CBVAVNum,r64)
              IF (FirstHVACIteration) THEN
                Par(2) = 1.d0
              ELSE
                Par(2) = 0.0d0
              END IF
              Par(3) = HeatCoilLoad
              CALL SolveRegulaFalsi(ErrTolerance, SolveMaxIter, SolFlag, HotWaterMdot, HotWaterCoilResidual, &
                                    MinWaterFlow, MaxHotWaterFlow, Par)
              IF (SolFlag == -1) THEN
                IF (CBVAV(CBVAVNum)%HotWaterCoilMaxIterIndex == 0) THEN
                  CALL ShowWarningMessage('CalcNonDXHeatingCoils: Hot water coil control failed for '//  &
                     trim(CBVAV(CBVAVNum)%UnitType)//'="'//  &
                     TRIM(CBVAV(CBVAVNum)%Name)//'"')
                  CALL ShowContinueErrorTimeStamp(' ')
                  CALL ShowContinueError('  Iteration limit ['//trim(RoundSigDigits(SolveMaxIter))//  &
                      '] exceeded in calculating hot water mass flow rate')
                ENDIF
                CALL ShowRecurringWarningErrorAtEnd('CalcNonDXHeatingCoils: Hot water coil control failed (iteration limit ['//  &
                   trim(RoundSigDigits(SolveMaxIter))//']) for '//trim(CBVAV(CBVAVNum)%UnitType)//'="'// &
                   TRIM(CBVAV(CBVAVNum)%Name),CBVAV(CBVAVNum)%HotWaterCoilMaxIterIndex)
              ELSE IF (SolFlag == -2) THEN
               IF (CBVAV(CBVAVNum)%HotWaterCoilMaxIterIndex2 == 0) THEN
                 CALL ShowWarningMessage('CalcNonDXHeatingCoils: Hot water coil control failed (maximum flow limits) for '//  &
                     trim(CBVAV(CBVAVNum)%UnitType)//'="'// &
                     TRIM(CBVAV(CBVAVNum)%Name)//'"')
                 CALL ShowContinueErrorTimeStamp(' ')
                 CALL ShowContinueError('...Bad hot water maximum flow rate limits')
                 CALL ShowContinueError('...Given minimum water flow rate='//trim(RoundSigDigits(MinWaterFlow,3))//' kg/s')
                 CALL ShowContinueError('...Given maximum water flow rate='//trim(RoundSigDigits(MaxHotWaterFlow,3))//' kg/s')
               ENDIF
               CALL ShowRecurringWarningErrorAtEnd('CalcNonDXHeatingCoils: Hot water coil control failed (flow limits) for '//  &
                   trim(CBVAV(CBVAVNum)%UnitType)//'="'// &
                   TRIM(CBVAV(CBVAVNum)%Name)//'"', &
                   CBVAV(CBVAVNum)%HotWaterCoilMaxIterIndex2,  &
                   ReportMinOf=MinWaterFlow,ReportMaxOf=MaxHotWaterFlow,ReportMinUnits='[kg/s]',ReportMaxUnits='[kg/s]')
              END IF
              ! simulate the hot water heating coil
              QCoilActual = HeatCoilLoad
              ! simulate the hot water heating coil
              CALL SimulateWaterCoilComponents(CBVAV(CBVAVNum)%HeatCoilName,FirstHVACIteration, &
                                               CBVAV(CBVAVNum)%HeatCoilIndex, QCoilActual, FanMode)
        ENDIF
        Case (Coil_HeatingSteam)
          mdot = CBVAV(CBVAVNum)%MaxHeatCoilFluidFlow
          Call SetComponentFlowRate( mdot , &
                                    CBVAV(CBVAVNum)%CoilControlNode, &
                                    CBVAV(CBVAVNum)%CoilOutletNode, &
                                    CBVAV(CBVAVNum)%LoopNum, &
                                    CBVAV(CBVAVNum)%LoopSide, &
                                    CBVAV(CBVAVNum)%BranchNum, &
                                    CBVAV(CBVAVNum)%CompNum)

          ! simulate the steam heating coil
          CALL SimulateSteamCoilComponents(CBVAV(CBVAVNum)%HeatCoilName, FirstHVACIteration, &
                                           HeatCoilLoad, CBVAV(CBVAVNum)%HeatCoilIndex, &
                                           QCoilActual, FanMode)
     END Select
  ELSE
     Select Case (CBVAV(CBVAVNum)%HeatCoilType_Num)
        Case (Coil_HeatingGas, Coil_HeatingElectric)
          CALL SimulateHeatingCoilComponents(CBVAV(CBVAVNum)%HeatCoilName,FirstHVACIteration, &
                                             HeatCoilLoad, CBVAV(CBVAVNum)%HeatCoilIndex, &
                                             QCoilActual, .TRUE., FanMode)
        Case (Coil_HeatingWater)
          mdot = 0.0d0
          Call SetComponentFlowRate( mdot , &
                                    CBVAV(CBVAVNum)%CoilControlNode, &
                                    CBVAV(CBVAVNum)%CoilOutletNode, &
                                    CBVAV(CBVAVNum)%LoopNum, &
                                    CBVAV(CBVAVNum)%LoopSide, &
                                    CBVAV(CBVAVNum)%BranchNum, &
                                    CBVAV(CBVAVNum)%CompNum)
          QCoilActual = HeatCoilLoad
          ! simulate the hot water heating coil
          CALL SimulateWaterCoilComponents(CBVAV(CBVAVNum)%HeatCoilName,FirstHVACIteration, &
                                           CBVAV(CBVAVNum)%HeatCoilIndex, QCoilActual, FanMode)
        Case (Coil_HeatingSteam)
          mdot = 0.0d0
          Call SetComponentFlowRate( mdot , &
                                    CBVAV(CBVAVNum)%CoilControlNode, &
                                    CBVAV(CBVAVNum)%CoilOutletNode, &
                                    CBVAV(CBVAVNum)%LoopNum, &
                                    CBVAV(CBVAVNum)%LoopSide, &
                                    CBVAV(CBVAVNum)%BranchNum, &
                                    CBVAV(CBVAVNum)%CompNum)
            ! simulate the steam heating coil
          CALL SimulateSteamCoilComponents(CBVAV(CBVAVNum)%HeatCoilName, FirstHVACIteration, &
                                           HeatCoilLoad, CBVAV(CBVAVNum)%HeatCoilIndex, &
                                           QCoilActual, FanMode)
     END Select
  ENDIF
  HeatCoilLoadmet = QCoilActual

 RETURN

END SUBROUTINE CalcNonDXHeatingCoils

FUNCTION HotWaterCoilResidual(HWFlow, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Bereket Nigusse, FSEC/UCF
          !       DATE WRITTEN   January 2012
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (Actual Coil Output - Requested Coil Load) / Requested Coil Load
          ! the actual coil output depends on the hot water flow rate which is varied to minimize the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls HotWaterCoilResidual, and calculates the residual as defined above.
          !

          ! REFERENCES:

          ! USE STATEMENTS:
  USE WaterCoils,     ONLY: SimulateWaterCoilComponents
  USE PlantUtilities, ONLY: SetComponentFlowRate


  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  REAL(r64), INTENT(IN)                         :: HWFlow   ! hot water flow rate in kg/s
  REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par      ! Par(5) is the requested coil load
  REAL(r64)                                     :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER               :: CBVAVNum
  LOGICAL               :: FirstHVACSoln
  REAL(r64)             :: QCoilActual             ! delivered coild load, W
  REAL(r64)             :: HeatCoilLoad            ! requested coild load, W
  REAL(r64)             :: mdot

  CBVAVNum = INT(Par(1))
  IF (Par(2) > 0.0d0) THEN
    FirstHVACSoln = .TRUE.
  ELSE
    FirstHVACSoln = .FALSE.
  END IF
  HeatCoilLoad =  Par(3)
  QCoilActual = HeatCoilLoad
  mdot = HWFlow
  Call SetComponentFlowRate( mdot , &
                             CBVAV(CBVAVNum)%CoilControlNode, &
                             CBVAV(CBVAVNum)%CoilOutletNode, &
                             CBVAV(CBVAVNum)%LoopNum, &
                             CBVAV(CBVAVNum)%LoopSide, &
                             CBVAV(CBVAVNum)%BranchNum, &
                             CBVAV(CBVAVNum)%CompNum)

    ! simulate the hot water supplemental heating coil
  CALL SimulateWaterCoilComponents(CBVAV(CBVAVNum)%HeatCoilName,FirstHVACSoln, &
                                   CBVAV(CBVAVNum)%HeatCoilIndex, QCoilActual, &
                                   CBVAV(CBVAVNum)%OpMode)
  IF (HeatCoilLoad /= 0.0d0) THEN
    Residuum = (QCoilActual - HeatCoilLoad)/ HeatCoilLoad
  ELSE !Objexx:Return Condition added to assure return value is set
    Residuum = 0.0d0
  ENDIF
  RETURN
END FUNCTION HotWaterCoilResidual

!     NOTICE
!
!     Copyright © 1996-2013 The Board of Trustees of the University of Illinois
!     and The Regents of the University of California through Ernest Orlando Lawrence
!     Berkeley National Laboratory.  All rights reserved.
!
!     Portions of the EnergyPlus software package have been developed and copyrighted
!     by other individuals, companies and institutions.  These portions have been
!     incorporated into the EnergyPlus software package under license.   For a complete
!     list of contributors, see "Notice" located in EnergyPlus.f90.
!
!     NOTICE: The U.S. Government is granted for itself and others acting on its
!     behalf a paid-up, nonexclusive, irrevocable, worldwide license in this data to
!     reproduce, prepare derivative works, and perform publicly and display publicly.
!     Beginning five (5) years after permission to assert copyright is granted,
!     subject to two possible five year renewals, the U.S. Government is granted for
!     itself and others acting on its behalf a paid-up, non-exclusive, irrevocable
!     worldwide license in this data to reproduce, prepare derivative works,
!     distribute copies to the public, perform publicly and display publicly, and to
!     permit others to do so.
!
!     TRADEMARKS: EnergyPlus is a trademark of the US Department of Energy.
!

END MODULE HVACUnitaryBypassVAV

AirflowNetworkBalanceManager.f90 AirflowNetworkSolver.f90 BaseboardRadiator.f90 BaseboardRadiatorElectric.f90 BaseboardRadiatorSteam.f90 BaseboardRadiatorWater.f90 BranchInputManager.f90 BranchNodeConnections.f90 ConductionTransferFunctionCalc.f90 CoolTower.f90 CostEstimateManager.f90 CurveManager.f90 CVFOnlyRoutines.f90 DataAirflowNetwork.f90 DataAirLoop.f90 DataAirSystems.f90 DataBranchAirLoopPlant.f90 DataBranchNodeConnections.f90 DataBSDFWindow.f90 DataComplexFenestration.f90 DataContaminantBalance.f90 DataConvergParams.f90 DataConversions.f90 DataCostEstimate.f90 DataDaylighting.f90 DataDaylightingDevices.f90 Datadefineequip.f90 DataDElight.f90 DataEnvironment.f90 DataEquivalentLayerWindow.f90 DataErrorTracking.f90 DataGenerators.f90 DataGlobalConstants.f90 DataGlobals.f90 DataHeatBalance.f90 DataHeatBalFanSys.f90 DataHeatBalSurface.f90 DataHVACControllers.f90 DataHVACGlobals.f90 DataInterfaces.f90 DataIPShortCuts.f90 DataLoopNode.f90 DataMoistureBalance.f90 DataMoistureBalanceEMPD.f90 DataOutputs.f90 DataPhotovoltaics.f90 DataPlant.f90 DataPlantPipingSystems.f90 DataPrecisionGlobals.f90 DataReportingFlags.f90 DataRoomAir.f90 DataRootFinder.f90 DataRuntimeLanguage.f90 DataShadowingCombinations.f90 DataSizing.f90 DataStringGlobals.f90 DataSurfaceColors.f90 DataSurfaceLists.f90 DataSurfaces.f90 DataSystemVariables.f90 DataTimings.f90 DataUCSDSharedData.f90 DataVectorTypes.f90 DataViewFactorInformation.f90 DataWater.f90 DataZoneControls.f90 DataZoneEnergyDemands.f90 DataZoneEquipment.f90 DaylightingDevices.f90 DaylightingManager.f90 DElightManagerF.f90 DElightManagerF_NO.f90 DemandManager.f90 DesiccantDehumidifiers.f90 DirectAir.f90 DisplayRoutines.f90 DXCoil.f90 EarthTube.f90 EconomicLifeCycleCost.f90 EconomicTariff.f90 EcoRoof.f90 ElectricPowerGenerators.f90 ElectricPowerManager.f90 EMSManager.f90 EnergyPlus.f90 ExteriorEnergyUseManager.f90 ExternalInterface_NO.f90 FanCoilUnits.f90 FaultsManager.f90 FluidProperties.f90 General.f90 GeneralRoutines.f90 GlobalNames.f90 HeatBalanceAirManager.f90 HeatBalanceConvectionCoeffs.f90 HeatBalanceHAMTManager.f90 HeatBalanceInternalHeatGains.f90 HeatBalanceIntRadExchange.f90 HeatBalanceManager.f90 HeatBalanceMovableInsulation.f90 HeatBalanceSurfaceManager.f90 HeatBalFiniteDifferenceManager.f90 HeatRecovery.f90 Humidifiers.f90 HVACControllers.f90 HVACCooledBeam.f90 HVACDualDuctSystem.f90 HVACDuct.f90 HVACDXSystem.f90 HVACEvapComponent.f90 HVACFanComponent.f90 HVACFurnace.f90 HVACHeatingCoils.f90 HVACHXAssistedCoolingCoil.f90 HVACInterfaceManager.f90 HVACManager.f90 HVACMixerComponent.f90 HVACMultiSpeedHeatPump.f90 HVACSingleDuctInduc.f90 HVACSingleDuctSystem.f90 HVACSplitterComponent.f90 HVACStandAloneERV.f90 HVACSteamCoilComponent.f90 HVACTranspiredCollector.f90 HVACUnitaryBypassVAV.f90 HVACUnitarySystem.f90 HVACVariableRefrigerantFlow.f90 HVACWaterCoilComponent.f90 HVACWatertoAir.f90 HVACWatertoAirMultiSpeedHP.f90 InputProcessor.f90 MatrixDataManager.f90 MixedAir.f90 MoistureBalanceEMPDManager.f90 NodeInputManager.f90 NonZoneEquipmentManager.f90 OutAirNodeManager.f90 OutdoorAirUnit.f90 OutputProcessor.f90 OutputReportPredefined.f90 OutputReports.f90 OutputReportTabular.f90 PackagedTerminalHeatPump.f90 PackagedThermalStorageCoil.f90 Photovoltaics.f90 PhotovoltaicThermalCollectors.f90 PlantAbsorptionChillers.f90 PlantBoilers.f90 PlantBoilersSteam.f90 PlantCentralGSHP.f90 PlantChillers.f90 PlantCondLoopOperation.f90 PlantCondLoopTowers.f90 PlantEIRChillers.f90 PlantEvapFluidCoolers.f90 PlantExhaustAbsorptionChiller.f90 PlantFluidCoolers.f90 PlantGasAbsorptionChiller.f90 PlantGroundHeatExchangers.f90 PlantHeatExchanger.f90 PlantIceThermalStorage.f90 PlantLoadProfile.f90 PlantLoopEquipment.f90 PlantLoopSolver.f90 PlantManager.f90 PlantOutsideEnergySources.f90 PlantPipeHeatTransfer.f90 PlantPipes.f90 PlantPipingSystemManager.f90 PlantPondGroundHeatExchanger.f90 PlantPressureSystem.f90 PlantPumps.f90 PlantSolarCollectors.f90 PlantSurfaceGroundHeatExchanger.f90 PlantUtilities.f90 PlantValves.f90 PlantWaterSources.f90 PlantWaterThermalTank.f90 PlantWatertoWaterGSHP.f90 PlantWaterUse.f90 PollutionAnalysisModule.f90 PoweredInductionUnits.f90 PsychRoutines.f90 Purchasedairmanager.f90 RadiantSystemHighTemp.f90 RadiantSystemLowTemp.f90 RefrigeratedCase.f90 ReportSizingManager.f90 ReturnAirPath.f90 RoomAirManager.f90 RoomAirModelCrossVent.f90 RoomAirModelDisplacementVent.f90 RoomAirModelMundt.f90 RoomAirModelUFAD.f90 RoomAirModelUserTempPattern.f90 RootFinder.f90 RuntimeLanguageProcessor.f90 ScheduleManager.f90 SetPointManager.f90 SimAirServingZones.f90 SimulationManager.f90 SizingManager.f90 SolarReflectionManager.f90 SolarShading.f90 SortAndStringUtilities.f90 sqlite3.c SQLiteCRoutines.c SQLiteFortranRoutines.f90 SQLiteFortranRoutines_NO.f90 StandardRatings.f90 SurfaceGeometry.f90 SystemAvailabilityManager.f90 SystemReports.f90 TarcogComplexFenestration.f90 ThermalChimney.f90 ThermalComfort.f90 UnitHeater.f90 UnitVentilator.f90 UserDefinedComponents.f90 UtilityRoutines.f90 VectorUtilities.f90 VentilatedSlab.f90 WaterManager.f90 WeatherManager.f90 WindowAC.f90 WindowComplexManager.f90 WindowEquivalentLayer.f90 WindowManager.f90 WindTurbine.f90 Zoneairloopequipmentmanager.f90 ZoneContaminantPredictorCorrector.f90 ZoneDehumidifier.f90 Zoneequipmentmanager.f90 ZonePlenumComponent.f90 ZoneTempPredictorCorrector.f90