sourcefile~~hvacunitarysystem.f90~~EfferentGraph sourcefile~hvacunitarysystem.f90 HVACUnitarySystem.f90 sourcefile~hvacwatertoair.f90 HVACWatertoAir.f90 sourcefile~hvacwatertoair.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datahvacglobals.f90 DataHVACGlobals.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacwatertoair.f90 sourcefile~hvacfancomponent.f90 HVACFanComponent.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacfancomponent.f90 sourcefile~hvachxassistedcoolingcoil.f90 HVACHXAssistedCoolingCoil.f90 sourcefile~datahvacglobals.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~datazoneequipment.f90 DataZoneEquipment.f90 sourcefile~datahvacglobals.f90->sourcefile~datazoneequipment.f90 sourcefile~setpointmanager.f90 SetPointManager.f90 sourcefile~datahvacglobals.f90->sourcefile~setpointmanager.f90 sourcefile~hvacheatingcoils.f90 HVACHeatingCoils.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacheatingcoils.f90 sourcefile~branchinputmanager.f90 BranchInputManager.f90 sourcefile~datahvacglobals.f90->sourcefile~branchinputmanager.f90 sourcefile~hvacdxsystem.f90 HVACDXSystem.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacdxsystem.f90 sourcefile~hvacwatercoilcomponent.f90 HVACWaterCoilComponent.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~general.f90 General.f90 sourcefile~datahvacglobals.f90->sourcefile~general.f90 sourcefile~dxcoil.f90 DXCoil.f90 sourcefile~datahvacglobals.f90->sourcefile~dxcoil.f90 sourcefile~hvacsteamcoilcomponent.f90 HVACSteamCoilComponent.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~hvacwatertoairmultispeedhp.f90 HVACWatertoAirMultiSpeedHP.f90 sourcefile~datahvacglobals.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~heatrecovery.f90 HeatRecovery.f90 sourcefile~datahvacglobals.f90->sourcefile~heatrecovery.f90 sourcefile~runtimelanguageprocessor.f90 RuntimeLanguageProcessor.f90 sourcefile~datahvacglobals.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~refrigeratedcase.f90 RefrigeratedCase.f90 sourcefile~datahvacglobals.f90->sourcefile~refrigeratedcase.f90 sourcefile~watermanager.f90 WaterManager.f90 sourcefile~datahvacglobals.f90->sourcefile~watermanager.f90 sourcefile~packagedthermalstoragecoil.f90 PackagedThermalStorageCoil.f90 sourcefile~datahvacglobals.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~plantwaterthermaltank.f90 PlantWaterThermalTank.f90 sourcefile~datahvacglobals.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~plantsolarcollectors.f90 PlantSolarCollectors.f90 sourcefile~datahvacglobals.f90->sourcefile~plantsolarcollectors.f90 sourcefile~standardratings.f90 StandardRatings.f90 sourcefile~datahvacglobals.f90->sourcefile~standardratings.f90 sourcefile~hvacfancomponent.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvacfancomponent.f90->sourcefile~dxcoil.f90 sourcefile~hvacfancomponent.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~hvachxassistedcoolingcoil.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvachxassistedcoolingcoil.f90->sourcefile~hvacdxsystem.f90 sourcefile~datahvaccontrollers.f90 DataHVACControllers.f90 sourcefile~datahvaccontrollers.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datazoneequipment.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datazoneequipment.f90->sourcefile~hvacfancomponent.f90 sourcefile~datazoneequipment.f90->sourcefile~setpointmanager.f90 sourcefile~datazoneequipment.f90->sourcefile~refrigeratedcase.f90 sourcefile~datazoneequipment.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~datazoneequipment.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~setpointmanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~setpointmanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~plantutilities.f90 PlantUtilities.f90 sourcefile~plantutilities.f90->sourcefile~hvacunitarysystem.f90 sourcefile~plantutilities.f90->sourcefile~hvacwatertoair.f90 sourcefile~plantutilities.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~plantutilities.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~plantutilities.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~plantutilities.f90->sourcefile~refrigeratedcase.f90 sourcefile~plantutilities.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~plantutilities.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataipshortcuts.f90 DataIPShortCuts.f90 sourcefile~dataipshortcuts.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataipshortcuts.f90->sourcefile~hvacheatingcoils.f90 sourcefile~curvemanager.f90 CurveManager.f90 sourcefile~dataipshortcuts.f90->sourcefile~curvemanager.f90 sourcefile~dataipshortcuts.f90->sourcefile~hvacdxsystem.f90 sourcefile~schedulemanager.f90 ScheduleManager.f90 sourcefile~dataipshortcuts.f90->sourcefile~schedulemanager.f90 sourcefile~dataipshortcuts.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataipshortcuts.f90->sourcefile~general.f90 sourcefile~inputprocessor.f90 InputProcessor.f90 sourcefile~dataipshortcuts.f90->sourcefile~inputprocessor.f90 sourcefile~dataipshortcuts.f90->sourcefile~heatrecovery.f90 sourcefile~outputprocessor.f90 OutputProcessor.f90 sourcefile~dataipshortcuts.f90->sourcefile~outputprocessor.f90 sourcefile~dataipshortcuts.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataipshortcuts.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataipshortcuts.f90->sourcefile~plantsolarcollectors.f90 sourcefile~datasizing.f90 DataSizing.f90 sourcefile~datasizing.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datasizing.f90->sourcefile~hvacwatertoair.f90 sourcefile~datasizing.f90->sourcefile~hvacfancomponent.f90 sourcefile~datasizing.f90->sourcefile~datazoneequipment.f90 sourcefile~datasizing.f90->sourcefile~plantutilities.f90 sourcefile~datasizing.f90->sourcefile~hvacheatingcoils.f90 sourcefile~datasizing.f90->sourcefile~branchinputmanager.f90 sourcefile~datasizing.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~datasizing.f90->sourcefile~dxcoil.f90 sourcefile~dataplant.f90 DataPlant.f90 sourcefile~datasizing.f90->sourcefile~dataplant.f90 sourcefile~datasizing.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~datasizing.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~datasizing.f90->sourcefile~inputprocessor.f90 sourcefile~datasizing.f90->sourcefile~heatrecovery.f90 sourcefile~datasizing.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~datasizing.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~emsmanager.f90 EMSManager.f90 sourcefile~emsmanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~emsmanager.f90->sourcefile~hvacfancomponent.f90 sourcefile~emsmanager.f90->sourcefile~setpointmanager.f90 sourcefile~emsmanager.f90->sourcefile~hvacheatingcoils.f90 sourcefile~emsmanager.f90->sourcefile~hvacdxsystem.f90 sourcefile~emsmanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~emsmanager.f90->sourcefile~dxcoil.f90 sourcefile~emsmanager.f90->sourcefile~heatrecovery.f90 sourcefile~datainterfaces.f90 DataInterfaces.f90 sourcefile~datainterfaces.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datainterfaces.f90->sourcefile~hvacwatertoair.f90 sourcefile~datainterfaces.f90->sourcefile~hvacfancomponent.f90 sourcefile~datainterfaces.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~datainterfaces.f90->sourcefile~datazoneequipment.f90 sourcefile~datainterfaces.f90->sourcefile~setpointmanager.f90 sourcefile~datainterfaces.f90->sourcefile~plantutilities.f90 sourcefile~datainterfaces.f90->sourcefile~emsmanager.f90 sourcefile~datainterfaces.f90->sourcefile~hvacheatingcoils.f90 sourcefile~reportsizingmanager.f90 ReportSizingManager.f90 sourcefile~datainterfaces.f90->sourcefile~reportsizingmanager.f90 sourcefile~datainterfaces.f90->sourcefile~branchinputmanager.f90 sourcefile~datainterfaces.f90->sourcefile~curvemanager.f90 sourcefile~dataenvironment.f90 DataEnvironment.f90 sourcefile~datainterfaces.f90->sourcefile~dataenvironment.f90 sourcefile~dataheatbalance.f90 DataHeatBalance.f90 sourcefile~datainterfaces.f90->sourcefile~dataheatbalance.f90 sourcefile~psychroutines.f90 PsychRoutines.f90 sourcefile~datainterfaces.f90->sourcefile~psychroutines.f90 sourcefile~branchnodeconnections.f90 BranchNodeConnections.f90 sourcefile~datainterfaces.f90->sourcefile~branchnodeconnections.f90 sourcefile~datainterfaces.f90->sourcefile~hvacdxsystem.f90 sourcefile~datainterfaces.f90->sourcefile~schedulemanager.f90 sourcefile~datainterfaces.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~datainterfaces.f90->sourcefile~general.f90 sourcefile~datainterfaces.f90->sourcefile~dxcoil.f90 sourcefile~datainterfaces.f90->sourcefile~dataplant.f90 sourcefile~nodeinputmanager.f90 NodeInputManager.f90 sourcefile~datainterfaces.f90->sourcefile~nodeinputmanager.f90 sourcefile~datainterfaces.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~fluidproperties.f90 FluidProperties.f90 sourcefile~datainterfaces.f90->sourcefile~fluidproperties.f90 sourcefile~datainterfaces.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~datainterfaces.f90->sourcefile~inputprocessor.f90 sourcefile~globalnames.f90 GlobalNames.f90 sourcefile~datainterfaces.f90->sourcefile~globalnames.f90 sourcefile~datainterfaces.f90->sourcefile~heatrecovery.f90 sourcefile~outairnodemanager.f90 OutAirNodeManager.f90 sourcefile~datainterfaces.f90->sourcefile~outairnodemanager.f90 sourcefile~datainterfaces.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~datainterfaces.f90->sourcefile~outputprocessor.f90 sourcefile~dataruntimelanguage.f90 DataRuntimeLanguage.f90 sourcefile~datainterfaces.f90->sourcefile~dataruntimelanguage.f90 sourcefile~sqlitefortranroutines.f90 SQLiteFortranRoutines.f90 sourcefile~datainterfaces.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~datainterfaces.f90->sourcefile~refrigeratedcase.f90 sourcefile~datainterfaces.f90->sourcefile~watermanager.f90 sourcefile~datainterfaces.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~datainterfaces.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~datainterfaces.f90->sourcefile~plantsolarcollectors.f90 sourcefile~datainterfaces.f90->sourcefile~standardratings.f90 sourcefile~datazonecontrols.f90 DataZoneControls.f90 sourcefile~datazonecontrols.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datazonecontrols.f90->sourcefile~setpointmanager.f90 sourcefile~datazonecontrols.f90->sourcefile~emsmanager.f90 sourcefile~hvacheatingcoils.f90->sourcefile~hvacunitarysystem.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacwatertoair.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacfancomponent.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacheatingcoils.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~reportsizingmanager.f90->sourcefile~dxcoil.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~reportsizingmanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~reportsizingmanager.f90->sourcefile~heatrecovery.f90 sourcefile~reportsizingmanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~reportsizingmanager.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataloopnode.f90 DataLoopNode.f90 sourcefile~dataloopnode.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataloopnode.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataloopnode.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataloopnode.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~dataloopnode.f90->sourcefile~datazoneequipment.f90 sourcefile~dataloopnode.f90->sourcefile~setpointmanager.f90 sourcefile~dataloopnode.f90->sourcefile~plantutilities.f90 sourcefile~dataloopnode.f90->sourcefile~emsmanager.f90 sourcefile~dataloopnode.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataloopnode.f90->sourcefile~branchinputmanager.f90 sourcefile~dataloopnode.f90->sourcefile~curvemanager.f90 sourcefile~dataloopnode.f90->sourcefile~branchnodeconnections.f90 sourcefile~dataloopnode.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataloopnode.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataloopnode.f90->sourcefile~dxcoil.f90 sourcefile~dataloopnode.f90->sourcefile~dataplant.f90 sourcefile~dataloopnode.f90->sourcefile~nodeinputmanager.f90 sourcefile~dataloopnode.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~dataloopnode.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataloopnode.f90->sourcefile~heatrecovery.f90 sourcefile~dataloopnode.f90->sourcefile~outairnodemanager.f90 sourcefile~dataloopnode.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataloopnode.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataloopnode.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataloopnode.f90->sourcefile~plantsolarcollectors.f90 sourcefile~branchinputmanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~branchinputmanager.f90->sourcefile~dataplant.f90 sourcefile~dataairsystems.f90 DataAirSystems.f90 sourcefile~dataairsystems.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataairsystems.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataairsystems.f90->sourcefile~setpointmanager.f90 sourcefile~dataairsystems.f90->sourcefile~emsmanager.f90 sourcefile~dataairsystems.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataairsystems.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataairsystems.f90->sourcefile~dxcoil.f90 sourcefile~dataairsystems.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataairsystems.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~curvemanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~curvemanager.f90->sourcefile~hvacwatertoair.f90 sourcefile~curvemanager.f90->sourcefile~hvacfancomponent.f90 sourcefile~curvemanager.f90->sourcefile~setpointmanager.f90 sourcefile~curvemanager.f90->sourcefile~hvacheatingcoils.f90 sourcefile~curvemanager.f90->sourcefile~branchinputmanager.f90 sourcefile~curvemanager.f90->sourcefile~dxcoil.f90 sourcefile~curvemanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~curvemanager.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~curvemanager.f90->sourcefile~refrigeratedcase.f90 sourcefile~curvemanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~curvemanager.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~curvemanager.f90->sourcefile~standardratings.f90 sourcefile~dataheatbalfansys.f90 DataHeatBalFanSys.f90 sourcefile~dataheatbalfansys.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataheatbalfansys.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataheatbalfansys.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataenvironment.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataenvironment.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataenvironment.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataenvironment.f90->sourcefile~setpointmanager.f90 sourcefile~dataenvironment.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataenvironment.f90->sourcefile~dataheatbalance.f90 sourcefile~dataenvironment.f90->sourcefile~psychroutines.f90 sourcefile~dataenvironment.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataenvironment.f90->sourcefile~schedulemanager.f90 sourcefile~dataenvironment.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataenvironment.f90->sourcefile~dxcoil.f90 sourcefile~dataenvironment.f90->sourcefile~nodeinputmanager.f90 sourcefile~dataenvironment.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~dataenvironment.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataenvironment.f90->sourcefile~heatrecovery.f90 sourcefile~dataenvironment.f90->sourcefile~outairnodemanager.f90 sourcefile~dataenvironment.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~dataenvironment.f90->sourcefile~outputprocessor.f90 sourcefile~dataenvironment.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~dataenvironment.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataenvironment.f90->sourcefile~watermanager.f90 sourcefile~dataenvironment.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataenvironment.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataenvironment.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataheatbalance.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataheatbalance.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~dataheatbalance.f90->sourcefile~datazoneequipment.f90 sourcefile~dataheatbalance.f90->sourcefile~setpointmanager.f90 sourcefile~dataheatbalance.f90->sourcefile~emsmanager.f90 sourcefile~dataheatbalance.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataheatbalance.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataheatbalance.f90->sourcefile~dxcoil.f90 sourcefile~dataheatbalance.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~dataheatbalance.f90->sourcefile~outputprocessor.f90 sourcefile~dataheatbalance.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~dataheatbalance.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataheatbalance.f90->sourcefile~watermanager.f90 sourcefile~dataheatbalance.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataheatbalance.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataheatbalance.f90->sourcefile~plantsolarcollectors.f90 sourcefile~psychroutines.f90->sourcefile~hvacunitarysystem.f90 sourcefile~psychroutines.f90->sourcefile~hvacwatertoair.f90 sourcefile~psychroutines.f90->sourcefile~hvacfancomponent.f90 sourcefile~psychroutines.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~psychroutines.f90->sourcefile~setpointmanager.f90 sourcefile~psychroutines.f90->sourcefile~hvacheatingcoils.f90 sourcefile~psychroutines.f90->sourcefile~hvacdxsystem.f90 sourcefile~psychroutines.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~psychroutines.f90->sourcefile~dxcoil.f90 sourcefile~psychroutines.f90->sourcefile~nodeinputmanager.f90 sourcefile~psychroutines.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~psychroutines.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~psychroutines.f90->sourcefile~heatrecovery.f90 sourcefile~psychroutines.f90->sourcefile~outairnodemanager.f90 sourcefile~psychroutines.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~psychroutines.f90->sourcefile~refrigeratedcase.f90 sourcefile~psychroutines.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~psychroutines.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~psychroutines.f90->sourcefile~plantsolarcollectors.f90 sourcefile~datazoneenergydemands.f90 DataZoneEnergyDemands.f90 sourcefile~datazoneenergydemands.f90->sourcefile~hvacunitarysystem.f90 sourcefile~datazoneenergydemands.f90->sourcefile~setpointmanager.f90 sourcefile~datazoneenergydemands.f90->sourcefile~refrigeratedcase.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacunitarysystem.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacwatertoair.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacfancomponent.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~branchnodeconnections.f90->sourcefile~datazoneequipment.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacheatingcoils.f90 sourcefile~branchnodeconnections.f90->sourcefile~branchinputmanager.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacdxsystem.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~branchnodeconnections.f90->sourcefile~dxcoil.f90 sourcefile~branchnodeconnections.f90->sourcefile~nodeinputmanager.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~branchnodeconnections.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~branchnodeconnections.f90->sourcefile~heatrecovery.f90 sourcefile~branchnodeconnections.f90->sourcefile~refrigeratedcase.f90 sourcefile~branchnodeconnections.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~branchnodeconnections.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~branchnodeconnections.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataairloop.f90 DataAirLoop.f90 sourcefile~dataairloop.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataairloop.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataairloop.f90->sourcefile~setpointmanager.f90 sourcefile~dataairloop.f90->sourcefile~emsmanager.f90 sourcefile~dataairloop.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataairloop.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataairloop.f90->sourcefile~dxcoil.f90 sourcefile~hvacdxsystem.f90->sourcefile~hvacunitarysystem.f90 sourcefile~schedulemanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~schedulemanager.f90->sourcefile~hvacfancomponent.f90 sourcefile~schedulemanager.f90->sourcefile~datazoneequipment.f90 sourcefile~schedulemanager.f90->sourcefile~setpointmanager.f90 sourcefile~schedulemanager.f90->sourcefile~emsmanager.f90 sourcefile~schedulemanager.f90->sourcefile~hvacheatingcoils.f90 sourcefile~schedulemanager.f90->sourcefile~hvacdxsystem.f90 sourcefile~schedulemanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~schedulemanager.f90->sourcefile~dxcoil.f90 sourcefile~schedulemanager.f90->sourcefile~nodeinputmanager.f90 sourcefile~schedulemanager.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~schedulemanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~schedulemanager.f90->sourcefile~heatrecovery.f90 sourcefile~schedulemanager.f90->sourcefile~outputprocessor.f90 sourcefile~schedulemanager.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~schedulemanager.f90->sourcefile~refrigeratedcase.f90 sourcefile~schedulemanager.f90->sourcefile~watermanager.f90 sourcefile~schedulemanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~schedulemanager.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~hvacwatercoilcomponent.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvacwatercoilcomponent.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~general.f90->sourcefile~hvacunitarysystem.f90 sourcefile~general.f90->sourcefile~hvacwatertoair.f90 sourcefile~general.f90->sourcefile~hvacfancomponent.f90 sourcefile~general.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~general.f90->sourcefile~datazoneequipment.f90 sourcefile~general.f90->sourcefile~setpointmanager.f90 sourcefile~general.f90->sourcefile~plantutilities.f90 sourcefile~general.f90->sourcefile~emsmanager.f90 sourcefile~general.f90->sourcefile~hvacheatingcoils.f90 sourcefile~general.f90->sourcefile~reportsizingmanager.f90 sourcefile~general.f90->sourcefile~branchinputmanager.f90 sourcefile~general.f90->sourcefile~curvemanager.f90 sourcefile~general.f90->sourcefile~dataenvironment.f90 sourcefile~general.f90->sourcefile~dataheatbalance.f90 sourcefile~general.f90->sourcefile~psychroutines.f90 sourcefile~general.f90->sourcefile~branchnodeconnections.f90 sourcefile~general.f90->sourcefile~hvacdxsystem.f90 sourcefile~general.f90->sourcefile~schedulemanager.f90 sourcefile~general.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~general.f90->sourcefile~dxcoil.f90 sourcefile~general.f90->sourcefile~dataplant.f90 sourcefile~general.f90->sourcefile~nodeinputmanager.f90 sourcefile~general.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~general.f90->sourcefile~fluidproperties.f90 sourcefile~general.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~general.f90->sourcefile~heatrecovery.f90 sourcefile~general.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~general.f90->sourcefile~outputprocessor.f90 sourcefile~general.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~general.f90->sourcefile~refrigeratedcase.f90 sourcefile~general.f90->sourcefile~watermanager.f90 sourcefile~general.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~general.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~general.f90->sourcefile~plantsolarcollectors.f90 sourcefile~general.f90->sourcefile~standardratings.f90 sourcefile~dxcoil.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dxcoil.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~dxcoil.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dxcoil.f90->sourcefile~hvacdxsystem.f90 sourcefile~dxcoil.f90->sourcefile~heatrecovery.f90 sourcefile~dxcoil.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataplant.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataplant.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataplant.f90->sourcefile~setpointmanager.f90 sourcefile~dataplant.f90->sourcefile~plantutilities.f90 sourcefile~dataplant.f90->sourcefile~dataairsystems.f90 sourcefile~dataplant.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataplant.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~dataplant.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataplant.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataplant.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataplant.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataplant.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataplant.f90->sourcefile~standardratings.f90 sourcefile~dataprecisionglobals.f90 DataPrecisionGlobals.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datahvacglobals.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datazoneequipment.f90 sourcefile~dataprecisionglobals.f90->sourcefile~setpointmanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~plantutilities.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataipshortcuts.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datasizing.f90 sourcefile~dataprecisionglobals.f90->sourcefile~emsmanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datainterfaces.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datazonecontrols.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataprecisionglobals.f90->sourcefile~reportsizingmanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataloopnode.f90 sourcefile~dataprecisionglobals.f90->sourcefile~branchinputmanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataairsystems.f90 sourcefile~dataprecisionglobals.f90->sourcefile~curvemanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataheatbalfansys.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataenvironment.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataheatbalance.f90 sourcefile~dataprecisionglobals.f90->sourcefile~psychroutines.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datazoneenergydemands.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataairloop.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataprecisionglobals.f90->sourcefile~schedulemanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataprecisionglobals.f90->sourcefile~general.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dxcoil.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataplant.f90 sourcefile~dataglobals.f90 DataGlobals.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataglobals.f90 sourcefile~dataairflownetwork.f90 DataAirflowNetwork.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataairflownetwork.f90 sourcefile~dataprecisionglobals.f90->sourcefile~nodeinputmanager.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~dataprecisionglobals.f90->sourcefile~fluidproperties.f90 sourcefile~dataprecisionglobals.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataprecisionglobals.f90->sourcefile~inputprocessor.f90 sourcefile~dataprecisionglobals.f90->sourcefile~globalnames.f90 sourcefile~outputreportpredefined.f90 OutputReportPredefined.f90 sourcefile~dataprecisionglobals.f90->sourcefile~outputreportpredefined.f90 sourcefile~datacontaminantbalance.f90 DataContaminantBalance.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datacontaminantbalance.f90 sourcefile~datasurfaces.f90 DataSurfaces.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datasurfaces.f90 sourcefile~datavectortypes.f90 DataVectorTypes.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datavectortypes.f90 sourcefile~databsdfwindow.f90 DataBSDFWindow.f90 sourcefile~dataprecisionglobals.f90->sourcefile~databsdfwindow.f90 sourcefile~dataprecisionglobals.f90->sourcefile~heatrecovery.f90 sourcefile~dataprecisionglobals.f90->sourcefile~outairnodemanager.f90 sourcefile~databranchairloopplant.f90 DataBranchAirLoopPlant.f90 sourcefile~dataprecisionglobals.f90->sourcefile~databranchairloopplant.f90 sourcefile~dataprecisionglobals.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~dataprecisionglobals.f90->sourcefile~outputprocessor.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataruntimelanguage.f90 sourcefile~datasystemvariables.f90 DataSystemVariables.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datasystemvariables.f90 sourcefile~dataprecisionglobals.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~dataroomair.f90 DataRoomAir.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataroomair.f90 sourcefile~dataprecisionglobals.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataprecisionglobals.f90->sourcefile~watermanager.f90 sourcefile~datawater.f90 DataWater.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datawater.f90 sourcefile~dataerrortracking.f90 DataErrorTracking.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataerrortracking.f90 sourcefile~datacomplexfenestration.f90 DataComplexFenestration.f90 sourcefile~dataprecisionglobals.f90->sourcefile~datacomplexfenestration.f90 sourcefile~dataequivalentlayerwindow.f90 DataEquivalentLayerWindow.f90 sourcefile~dataprecisionglobals.f90->sourcefile~dataequivalentlayerwindow.f90 sourcefile~dataprecisionglobals.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataprecisionglobals.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataprecisionglobals.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataprecisionglobals.f90->sourcefile~standardratings.f90 sourcefile~dataglobals.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataglobals.f90->sourcefile~hvacwatertoair.f90 sourcefile~dataglobals.f90->sourcefile~datahvacglobals.f90 sourcefile~dataglobals.f90->sourcefile~hvacfancomponent.f90 sourcefile~dataglobals.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~dataglobals.f90->sourcefile~datazoneequipment.f90 sourcefile~dataglobals.f90->sourcefile~setpointmanager.f90 sourcefile~dataglobals.f90->sourcefile~plantutilities.f90 sourcefile~dataglobals.f90->sourcefile~dataipshortcuts.f90 sourcefile~dataglobals.f90->sourcefile~datasizing.f90 sourcefile~dataglobals.f90->sourcefile~emsmanager.f90 sourcefile~dataglobals.f90->sourcefile~datazonecontrols.f90 sourcefile~dataglobals.f90->sourcefile~hvacheatingcoils.f90 sourcefile~dataglobals.f90->sourcefile~reportsizingmanager.f90 sourcefile~dataglobals.f90->sourcefile~dataloopnode.f90 sourcefile~dataglobals.f90->sourcefile~branchinputmanager.f90 sourcefile~dataglobals.f90->sourcefile~dataairsystems.f90 sourcefile~dataglobals.f90->sourcefile~curvemanager.f90 sourcefile~dataglobals.f90->sourcefile~dataenvironment.f90 sourcefile~dataglobals.f90->sourcefile~dataheatbalance.f90 sourcefile~dataglobals.f90->sourcefile~psychroutines.f90 sourcefile~dataglobals.f90->sourcefile~branchnodeconnections.f90 sourcefile~dataglobals.f90->sourcefile~dataairloop.f90 sourcefile~dataglobals.f90->sourcefile~hvacdxsystem.f90 sourcefile~dataglobals.f90->sourcefile~schedulemanager.f90 sourcefile~dataglobals.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~dataglobals.f90->sourcefile~general.f90 sourcefile~dataglobals.f90->sourcefile~dxcoil.f90 sourcefile~dataglobals.f90->sourcefile~dataplant.f90 sourcefile~dataglobals.f90->sourcefile~dataairflownetwork.f90 sourcefile~dataglobals.f90->sourcefile~nodeinputmanager.f90 sourcefile~dataglobals.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~dataglobals.f90->sourcefile~fluidproperties.f90 sourcefile~dataglobals.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~dataglobals.f90->sourcefile~inputprocessor.f90 sourcefile~dataglobals.f90->sourcefile~globalnames.f90 sourcefile~dataglobals.f90->sourcefile~outputreportpredefined.f90 sourcefile~dataglobals.f90->sourcefile~datacontaminantbalance.f90 sourcefile~dataglobals.f90->sourcefile~datasurfaces.f90 sourcefile~dataglobals.f90->sourcefile~databsdfwindow.f90 sourcefile~dataglobals.f90->sourcefile~heatrecovery.f90 sourcefile~dataglobals.f90->sourcefile~outairnodemanager.f90 sourcefile~dataglobals.f90->sourcefile~databranchairloopplant.f90 sourcefile~dataglobals.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~dataglobals.f90->sourcefile~outputprocessor.f90 sourcefile~dataglobals.f90->sourcefile~dataruntimelanguage.f90 sourcefile~sortandstringutilities.f90 SortAndStringUtilities.f90 sourcefile~dataglobals.f90->sourcefile~sortandstringutilities.f90 sourcefile~dataoutputs.f90 DataOutputs.f90 sourcefile~dataglobals.f90->sourcefile~dataoutputs.f90 sourcefile~dataglobals.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~dataglobalconstants.f90 DataGlobalConstants.f90 sourcefile~dataglobals.f90->sourcefile~dataglobalconstants.f90 sourcefile~dataglobals.f90->sourcefile~dataroomair.f90 sourcefile~dataglobals.f90->sourcefile~refrigeratedcase.f90 sourcefile~dataglobals.f90->sourcefile~watermanager.f90 sourcefile~dataglobals.f90->sourcefile~datawater.f90 sourcefile~dataglobals.f90->sourcefile~datacomplexfenestration.f90 sourcefile~dataglobals.f90->sourcefile~dataequivalentlayerwindow.f90 sourcefile~databranchnodeconnections.f90 DataBranchNodeConnections.f90 sourcefile~dataglobals.f90->sourcefile~databranchnodeconnections.f90 sourcefile~dataglobals.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataglobals.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~dataglobals.f90->sourcefile~plantsolarcollectors.f90 sourcefile~dataglobals.f90->sourcefile~standardratings.f90 sourcefile~dataairflownetwork.f90->sourcefile~hvacunitarysystem.f90 sourcefile~dataairflownetwork.f90->sourcefile~hvacfancomponent.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacunitarysystem.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacwatertoair.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacfancomponent.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~nodeinputmanager.f90->sourcefile~datazoneequipment.f90 sourcefile~nodeinputmanager.f90->sourcefile~setpointmanager.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacheatingcoils.f90 sourcefile~nodeinputmanager.f90->sourcefile~branchinputmanager.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacdxsystem.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~nodeinputmanager.f90->sourcefile~dxcoil.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~nodeinputmanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~nodeinputmanager.f90->sourcefile~heatrecovery.f90 sourcefile~nodeinputmanager.f90->sourcefile~outairnodemanager.f90 sourcefile~nodeinputmanager.f90->sourcefile~refrigeratedcase.f90 sourcefile~nodeinputmanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~nodeinputmanager.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~nodeinputmanager.f90->sourcefile~plantsolarcollectors.f90 sourcefile~hvacsteamcoilcomponent.f90->sourcefile~hvacunitarysystem.f90 sourcefile~fluidproperties.f90->sourcefile~hvacunitarysystem.f90 sourcefile~fluidproperties.f90->sourcefile~hvacwatertoair.f90 sourcefile~fluidproperties.f90->sourcefile~plantutilities.f90 sourcefile~fluidproperties.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~fluidproperties.f90->sourcefile~nodeinputmanager.f90 sourcefile~fluidproperties.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~fluidproperties.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~fluidproperties.f90->sourcefile~refrigeratedcase.f90 sourcefile~fluidproperties.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~fluidproperties.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~fluidproperties.f90->sourcefile~plantsolarcollectors.f90 sourcefile~fluidproperties.f90->sourcefile~standardratings.f90 sourcefile~hvacwatertoairmultispeedhp.f90->sourcefile~hvacunitarysystem.f90 sourcefile~hvacwatertoairmultispeedhp.f90->sourcefile~hvacdxsystem.f90 sourcefile~inputprocessor.f90->sourcefile~hvacunitarysystem.f90 sourcefile~inputprocessor.f90->sourcefile~hvacwatertoair.f90 sourcefile~inputprocessor.f90->sourcefile~hvacfancomponent.f90 sourcefile~inputprocessor.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~inputprocessor.f90->sourcefile~datazoneequipment.f90 sourcefile~inputprocessor.f90->sourcefile~setpointmanager.f90 sourcefile~inputprocessor.f90->sourcefile~emsmanager.f90 sourcefile~inputprocessor.f90->sourcefile~hvacheatingcoils.f90 sourcefile~inputprocessor.f90->sourcefile~branchinputmanager.f90 sourcefile~inputprocessor.f90->sourcefile~curvemanager.f90 sourcefile~inputprocessor.f90->sourcefile~dataheatbalance.f90 sourcefile~inputprocessor.f90->sourcefile~branchnodeconnections.f90 sourcefile~inputprocessor.f90->sourcefile~hvacdxsystem.f90 sourcefile~inputprocessor.f90->sourcefile~schedulemanager.f90 sourcefile~inputprocessor.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~inputprocessor.f90->sourcefile~general.f90 sourcefile~inputprocessor.f90->sourcefile~dxcoil.f90 sourcefile~inputprocessor.f90->sourcefile~dataplant.f90 sourcefile~inputprocessor.f90->sourcefile~nodeinputmanager.f90 sourcefile~inputprocessor.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~inputprocessor.f90->sourcefile~fluidproperties.f90 sourcefile~inputprocessor.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~inputprocessor.f90->sourcefile~globalnames.f90 sourcefile~inputprocessor.f90->sourcefile~heatrecovery.f90 sourcefile~inputprocessor.f90->sourcefile~outairnodemanager.f90 sourcefile~inputprocessor.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~inputprocessor.f90->sourcefile~outputprocessor.f90 sourcefile~inputprocessor.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~inputprocessor.f90->sourcefile~dataglobalconstants.f90 sourcefile~inputprocessor.f90->sourcefile~refrigeratedcase.f90 sourcefile~inputprocessor.f90->sourcefile~watermanager.f90 sourcefile~inputprocessor.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~inputprocessor.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~inputprocessor.f90->sourcefile~plantsolarcollectors.f90 sourcefile~globalnames.f90->sourcefile~hvacwatertoair.f90 sourcefile~globalnames.f90->sourcefile~hvacheatingcoils.f90 sourcefile~globalnames.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~globalnames.f90->sourcefile~dxcoil.f90 sourcefile~globalnames.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~globalnames.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~globalnames.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~globalnames.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~outputreportpredefined.f90->sourcefile~hvacwatertoair.f90 sourcefile~outputreportpredefined.f90->sourcefile~hvacfancomponent.f90 sourcefile~outputreportpredefined.f90->sourcefile~hvacheatingcoils.f90 sourcefile~outputreportpredefined.f90->sourcefile~reportsizingmanager.f90 sourcefile~outputreportpredefined.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~outputreportpredefined.f90->sourcefile~dxcoil.f90 sourcefile~outputreportpredefined.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~outputreportpredefined.f90->sourcefile~outputprocessor.f90 sourcefile~outputreportpredefined.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~outputreportpredefined.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~outputreportpredefined.f90->sourcefile~standardratings.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacwatertoair.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacfancomponent.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacheatingcoils.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~datacontaminantbalance.f90->sourcefile~dxcoil.f90 sourcefile~datacontaminantbalance.f90->sourcefile~nodeinputmanager.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacsteamcoilcomponent.f90 sourcefile~datacontaminantbalance.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~datacontaminantbalance.f90->sourcefile~heatrecovery.f90 sourcefile~datacontaminantbalance.f90->sourcefile~outairnodemanager.f90 sourcefile~datasurfaces.f90->sourcefile~emsmanager.f90 sourcefile~datasurfaces.f90->sourcefile~dataheatbalance.f90 sourcefile~datasurfaces.f90->sourcefile~general.f90 sourcefile~datasurfaces.f90->sourcefile~datacontaminantbalance.f90 sourcefile~datasurfaces.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~datasurfaces.f90->sourcefile~watermanager.f90 sourcefile~datasurfaces.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~datasurfaces.f90->sourcefile~plantsolarcollectors.f90 sourcefile~datavectortypes.f90->sourcefile~dataheatbalance.f90 sourcefile~datavectortypes.f90->sourcefile~datasurfaces.f90 sourcefile~datavectortypes.f90->sourcefile~databsdfwindow.f90 sourcefile~databsdfwindow.f90->sourcefile~dataheatbalance.f90 sourcefile~databsdfwindow.f90->sourcefile~datasurfaces.f90 sourcefile~heatrecovery.f90->sourcefile~hvachxassistedcoolingcoil.f90 sourcefile~outairnodemanager.f90->sourcefile~setpointmanager.f90 sourcefile~outairnodemanager.f90->sourcefile~emsmanager.f90 sourcefile~outairnodemanager.f90->sourcefile~dxcoil.f90 sourcefile~outairnodemanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~outairnodemanager.f90->sourcefile~refrigeratedcase.f90 sourcefile~outairnodemanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~outairnodemanager.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~databranchairloopplant.f90->sourcefile~plantutilities.f90 sourcefile~databranchairloopplant.f90->sourcefile~branchinputmanager.f90 sourcefile~databranchairloopplant.f90->sourcefile~curvemanager.f90 sourcefile~databranchairloopplant.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~databranchairloopplant.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~databranchairloopplant.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~databranchairloopplant.f90->sourcefile~standardratings.f90 sourcefile~runtimelanguageprocessor.f90->sourcefile~emsmanager.f90 sourcefile~outputprocessor.f90->sourcefile~emsmanager.f90 sourcefile~outputprocessor.f90->sourcefile~nodeinputmanager.f90 sourcefile~outputprocessor.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~dataruntimelanguage.f90->sourcefile~emsmanager.f90 sourcefile~dataruntimelanguage.f90->sourcefile~general.f90 sourcefile~dataruntimelanguage.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~datasystemvariables.f90->sourcefile~curvemanager.f90 sourcefile~datasystemvariables.f90->sourcefile~schedulemanager.f90 sourcefile~datasystemvariables.f90->sourcefile~inputprocessor.f90 sourcefile~datasystemvariables.f90->sourcefile~runtimelanguageprocessor.f90 sourcefile~datasystemvariables.f90->sourcefile~outputprocessor.f90 sourcefile~datasystemvariables.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~datastringglobals.f90 DataStringGlobals.f90 sourcefile~datastringglobals.f90->sourcefile~schedulemanager.f90 sourcefile~datastringglobals.f90->sourcefile~general.f90 sourcefile~datastringglobals.f90->sourcefile~inputprocessor.f90 sourcefile~datastringglobals.f90->sourcefile~outputprocessor.f90 sourcefile~datastringglobals.f90->sourcefile~datasystemvariables.f90 sourcefile~datastringglobals.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~sortandstringutilities.f90->sourcefile~inputprocessor.f90 sourcefile~sortandstringutilities.f90->sourcefile~outputprocessor.f90 sourcefile~dataoutputs.f90->sourcefile~inputprocessor.f90 sourcefile~dataoutputs.f90->sourcefile~outputprocessor.f90 sourcefile~sqlitefortranroutines.f90->sourcefile~reportsizingmanager.f90 sourcefile~sqlitefortranroutines.f90->sourcefile~outputprocessor.f90 sourcefile~dataglobalconstants.f90->sourcefile~outputprocessor.f90 sourcefile~dataroomair.f90->sourcefile~sqlitefortranroutines.f90 sourcefile~refrigeratedcase.f90->sourcefile~hvacheatingcoils.f90 sourcefile~refrigeratedcase.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~watermanager.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~watermanager.f90->sourcefile~dxcoil.f90 sourcefile~watermanager.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~watermanager.f90->sourcefile~refrigeratedcase.f90 sourcefile~watermanager.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~datawater.f90->sourcefile~hvacwatercoilcomponent.f90 sourcefile~datawater.f90->sourcefile~dxcoil.f90 sourcefile~datawater.f90->sourcefile~hvacwatertoairmultispeedhp.f90 sourcefile~datawater.f90->sourcefile~refrigeratedcase.f90 sourcefile~datawater.f90->sourcefile~watermanager.f90 sourcefile~datawater.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~dataerrortracking.f90->sourcefile~branchinputmanager.f90 sourcefile~dataerrortracking.f90->sourcefile~nodeinputmanager.f90 sourcefile~datacomplexfenestration.f90->sourcefile~dataheatbalance.f90 sourcefile~dataequivalentlayerwindow.f90->sourcefile~dataheatbalance.f90 sourcefile~databranchnodeconnections.f90->sourcefile~branchnodeconnections.f90 sourcefile~databranchnodeconnections.f90->sourcefile~dxcoil.f90 sourcefile~packagedthermalstoragecoil.f90->sourcefile~hvacdxsystem.f90 sourcefile~plantwaterthermaltank.f90->sourcefile~packagedthermalstoragecoil.f90 sourcefile~plantsolarcollectors.f90->sourcefile~plantwaterthermaltank.f90 sourcefile~standardratings.f90->sourcefile~dxcoil.f90
Help

Files Dependent On This One

sourcefile~~hvacunitarysystem.f90~~AfferentGraph sourcefile~hvacunitarysystem.f90 HVACUnitarySystem.f90 sourcefile~simairservingzones.f90 SimAirServingZones.f90 sourcefile~hvacunitarysystem.f90->sourcefile~simairservingzones.f90 sourcefile~zoneequipmentmanager.f90 Zoneequipmentmanager.f90 sourcefile~hvacunitarysystem.f90->sourcefile~zoneequipmentmanager.f90 sourcefile~outdoorairunit.f90 OutdoorAirUnit.f90 sourcefile~hvacunitarysystem.f90->sourcefile~outdoorairunit.f90 sourcefile~mixedair.f90 MixedAir.f90 sourcefile~hvacunitarysystem.f90->sourcefile~mixedair.f90 sourcefile~sizingmanager.f90 SizingManager.f90 sourcefile~simairservingzones.f90->sourcefile~sizingmanager.f90 sourcefile~hvacmanager.f90 HVACManager.f90 sourcefile~simairservingzones.f90->sourcefile~hvacmanager.f90 sourcefile~zoneequipmentmanager.f90->sourcefile~sizingmanager.f90 sourcefile~zoneequipmentmanager.f90->sourcefile~hvacmanager.f90 sourcefile~outdoorairunit.f90->sourcefile~zoneequipmentmanager.f90 sourcefile~generalroutines.f90 GeneralRoutines.f90 sourcefile~outdoorairunit.f90->sourcefile~generalroutines.f90 sourcefile~mixedair.f90->sourcefile~simairservingzones.f90 sourcefile~simulationmanager.f90 SimulationManager.f90 sourcefile~mixedair.f90->sourcefile~simulationmanager.f90 sourcefile~hvacstandaloneerv.f90 HVACStandAloneERV.f90 sourcefile~mixedair.f90->sourcefile~hvacstandaloneerv.f90 sourcefile~hvaccontrollers.f90 HVACControllers.f90 sourcefile~mixedair.f90->sourcefile~hvaccontrollers.f90 sourcefile~packagedterminalheatpump.f90 PackagedTerminalHeatPump.f90 sourcefile~mixedair.f90->sourcefile~packagedterminalheatpump.f90 sourcefile~airflownetworkbalancemanager.f90 AirflowNetworkBalanceManager.f90 sourcefile~mixedair.f90->sourcefile~airflownetworkbalancemanager.f90 sourcefile~hvacvariablerefrigerantflow.f90 HVACVariableRefrigerantFlow.f90 sourcefile~mixedair.f90->sourcefile~hvacvariablerefrigerantflow.f90 sourcefile~hvacunitarybypassvav.f90 HVACUnitaryBypassVAV.f90 sourcefile~mixedair.f90->sourcefile~hvacunitarybypassvav.f90 sourcefile~fancoilunits.f90 FanCoilUnits.f90 sourcefile~mixedair.f90->sourcefile~fancoilunits.f90 sourcefile~windowac.f90 WindowAC.f90 sourcefile~mixedair.f90->sourcefile~windowac.f90 sourcefile~sizingmanager.f90->sourcefile~simulationmanager.f90 sourcefile~hvacmanager.f90->sourcefile~simulationmanager.f90 sourcefile~heatbalanceairmanager.f90 HeatBalanceAirManager.f90 sourcefile~hvacmanager.f90->sourcefile~heatbalanceairmanager.f90 sourcefile~energyplus.f90 EnergyPlus.f90 sourcefile~simulationmanager.f90->sourcefile~energyplus.f90 sourcefile~utilityroutines.f90 UtilityRoutines.f90 sourcefile~simulationmanager.f90->sourcefile~utilityroutines.f90 sourcefile~heatbalanceairmanager.f90->sourcefile~simulationmanager.f90 sourcefile~heatbalancesurfacemanager.f90 HeatBalanceSurfaceManager.f90 sourcefile~heatbalanceairmanager.f90->sourcefile~heatbalancesurfacemanager.f90 sourcefile~heatbalancesurfacemanager.f90->sourcefile~simulationmanager.f90 sourcefile~heatbalancemanager.f90 HeatBalanceManager.f90 sourcefile~heatbalancesurfacemanager.f90->sourcefile~heatbalancemanager.f90 sourcefile~heatbalancemanager.f90->sourcefile~sizingmanager.f90 sourcefile~heatbalancemanager.f90->sourcefile~simulationmanager.f90 sourcefile~hvacstandaloneerv.f90->sourcefile~zoneequipmentmanager.f90 sourcefile~hvacstandaloneerv.f90->sourcefile~hvacmanager.f90 sourcefile~systemreports.f90 SystemReports.f90 sourcefile~hvacstandaloneerv.f90->sourcefile~systemreports.f90 sourcefile~hvaccontrollers.f90->sourcefile~simairservingzones.f90 sourcefile~hvaccontrollers.f90->sourcefile~simulationmanager.f90 sourcefile~hvacfurnace.f90 HVACFurnace.f90 sourcefile~hvaccontrollers.f90->sourcefile~hvacfurnace.f90 sourcefile~packagedterminalheatpump.f90->sourcefile~zoneequipmentmanager.f90 sourcefile~packagedterminalheatpump.f90->sourcefile~systemreports.f90 sourcefile~airflownetworkbalancemanager.f90->sourcefile~hvacmanager.f90 sourcefile~systemavailabilitymanager.f90 SystemAvailabilityManager.f90 sourcefile~airflownetworkbalancemanager.f90->sourcefile~systemavailabilitymanager.f90 sourcefile~hvacvariablerefrigerantflow.f90->sourcefile~zoneequipmentmanager.f90 sourcefile~plantloopequipment.f90 PlantLoopEquipment.f90 sourcefile~hvacvariablerefrigerantflow.f90->sourcefile~plantloopequipment.f90 sourcefile~hvacunitarybypassvav.f90->sourcefile~simairservingzones.f90 sourcefile~fancoilunits.f90->sourcefile~zoneequipmentmanager.f90 sourcefile~fancoilunits.f90->sourcefile~generalroutines.f90 sourcefile~fancoilunits.f90->sourcefile~systemreports.f90 sourcefile~windowac.f90->sourcefile~zoneequipmentmanager.f90 sourcefile~windowac.f90->sourcefile~systemreports.f90 sourcefile~systemreports.f90->sourcefile~hvacmanager.f90 sourcefile~systemreports.f90->sourcefile~simulationmanager.f90 sourcefile~systemreports.f90->sourcefile~utilityroutines.f90 sourcefile~hvacfurnace.f90->sourcefile~simairservingzones.f90 sourcefile~systemavailabilitymanager.f90->sourcefile~simairservingzones.f90 sourcefile~systemavailabilitymanager.f90->sourcefile~zoneequipmentmanager.f90 sourcefile~systemavailabilitymanager.f90->sourcefile~hvacmanager.f90 sourcefile~systemavailabilitymanager.f90->sourcefile~heatbalanceairmanager.f90 sourcefile~plantmanager.f90 PlantManager.f90 sourcefile~systemavailabilitymanager.f90->sourcefile~plantmanager.f90 sourcefile~plantmanager.f90->sourcefile~hvacmanager.f90 sourcefile~plantmanager.f90->sourcefile~simulationmanager.f90 sourcefile~plantmanager.f90->sourcefile~utilityroutines.f90 sourcefile~plantloopequipment.f90->sourcefile~plantmanager.f90 sourcefile~plantloopsolver.f90 PlantLoopSolver.f90 sourcefile~plantloopequipment.f90->sourcefile~plantloopsolver.f90 sourcefile~plantloopsolver.f90->sourcefile~plantmanager.f90
Help

Source Code


Source Code

MODULE HVACUnitarySystem
  ! Module containing the Unitary System simulation routines
  ! AirloopHVAC:UnitarySystem
  ! Unitary System allows any coil type with fan and coils optional
  ! Unitary System model can be placed anywhere in the simulation:
  !   (air loops, outside air systems, Outdoor air units, zone equipment)
  !   ( not fully tested for all configurations)
  !
  ! Routine calling order:
  !
  !  SimUnitarySystem
  !    GetUnitarySystemInput
  !    InitUnitarySystems
  !    IF(SetPointBased Control)THEN
  !      ControlUnitarySystemToSP   ---->  SimFan (if exists and blowthru)
  !                                        UpdateUnitarySystemControl (cooling coil if exists)
  !                                        ControlCoolingSystem ---> Sim*CoolingCoil
  !                                        CalcUnitaryCoolingSystem
  !                                        UpdateUnitarySystemControl (heating coil if exists)
  !                                        ControlHeatingSystem ---> Sim*HeatingCoil
  !                                        CalcUnitaryHeatingSystem
  !                                        SimFan (if exists and drawthru)
  !                                        UpdateUnitarySystemControl (supp heating coil if exists)
  !                                        ControlSuppHeatingSystem ---> Sim*HeatingCoil
  !                                        CalcUnitarySuppSystemToSP
  !    ELSEIF(LoadBased Control)THEN
  !      ControlUnitarySystemToLoad ---->  UpdateUnitarySystemControl
  !                                        ControlUnitarySystemOutput ---> CalcUnitarySystemToLoad(PLR)
  !                                        CalcUnitarySystemToLoad(FinalPLR w/ supp heater operating)
  !    END IF
  !
  !  ReportUnitarySystem(UnitarySysNum)
  !
  ! MODULE INFORMATION:
  !       AUTHOR         Richard Raustad, FSEC
  !       DATE WRITTEN   February 2013
  !       RE-ENGINEERED  na

  ! PURPOSE OF THIS MODULE:
  ! To encapsulate the data and algorithms required to
  ! manage the Unitary System Component

  ! METHODOLOGY EMPLOYED:
  ! Calculates the part-load ratio of the HVAC system to meet the zone sensible load.
  ! IF humidity control is specified and the latent capacity at the sensible PLR is insufficient to meet the latent load,
  ! enable multimode operation and calculate a part-load ratio to meet the zone sensible load (MultiMode dehumidification control)
  ! or the zone latent load (CoolReheat dehumidification control).
  !
  ! Subroutines:
  !
  ! SimUnitarySystem - Top level simulate routine CALLed by other modules. Each child object is simulated a final time after
  !                    the part-load ratio for child components has been determined.
  !
  !  Note: A supplemental heater augments the heating capacity for both air-to-air and water-to-air heat pump systems.
  !        The supplemental heating coil may be present even if the system is not a heat pump.
  !        The supplemental heating coil is used in the unitarysystem to meet the sensible load when the
  !        primary heating coil is unable to meet the zone load.
  !
  !
  ! Dehumidificaiton control options:
  !
  ! Dehumidification Control NONE:   If a HX assisted cooling coil is selected, the HX is always active (cooling).
  !
  ! Dehumidification Control COOLREHEAT: For cooling operation, the sensible capacity is calculated to
  !                                      meet the thermostat setpoint. If a HX assisted cooling coil is selected,
  !                                      the HX is always active. If the latent load is not met by operating the
  !                                      system at the sensible PLR, a new PLR is calculated to meet the humidistat
  !                                      setpoint. The supplemental heating coil load is then calculated to meet the
  !                                      HEATING setpoint temperature.
  !
  ! Dehumidification Control MULTIMODE: For cooling operation, the sensible capacity is calculated to
  !                                     meet the thermostat setpoint. If a HX assisted cooling coil is selected,
  !                                     the HX is off for this calculation. If the latent load is not met by operating
  !                                     the system at the sensible PLR, a new PLR is calculated with the HX operating
  !                                     and the target is the zone SENSIBLE load (thermostat setpoint). Humidity is not
  !                                     controlled in this mode. No reheat coil is needed in this configuration.
  !
  !
  ! REFERENCES:

  ! OTHER NOTES:  This module is intended to allow any configuration of coil types and location. All possible configurations
  !               have not been fully tested, however, the methodology is to treat all configurations the same. No special
  !               treatment is desired (e.g., IF coiltype == X THEN do this ELSE do something else). DX coils have not been
  !               included as supplemental heating coils, however, there is no reason other than the DX coil module may not
  !               allow a heating only DX system.
  !
  ! USE STATEMENTS:
  ! Use statements for data only modules
USE DataPrecisionGlobals
USE DataLoopNode
USE DataAirloop
USE DataGlobals
USE DataHVACGlobals
USE DataInterfaces
USE DataSizing
USE DataZoneEquipment
USE DataEnvironment, ONLY: StdBaroPress,EnvironmentName,CurMnDy,OutDryBulbTemp,OutHumRat,OutBaroPress,OutWetBulbTemp,StdRhoAir

  ! Use statements for access to subroutines in other modules
USE VariableSpeedCoils, ONLY:MaxSpedLevels
USE ScheduleManager

IMPLICIT NONE         ! Enforce explicit typing of all variables

PRIVATE ! Everything private unless explicitly made public

  !MODULE PARAMETER DEFINITIONS
REAL(r64), PARAMETER :: MinAirMassFlow = 0.001d0

! Last mode of operation
INTEGER, PARAMETER :: CoolingMode = 1 ! last compressor operating mode was in cooling
INTEGER, PARAMETER :: HeatingMode = 2 ! last compressor operating mode was in heating

! Compressor operation
INTEGER, PARAMETER :: On  = 1              ! normal compressor operation
INTEGER, PARAMETER :: Off = 0              ! signal DXCoil that compressor shouldn't run

! Dehumidification control modes (DehumidControlMode)
INTEGER, PARAMETER :: DehumidControl_None       = 0
INTEGER, PARAMETER :: DehumidControl_Multimode  = 1
INTEGER, PARAMETER :: DehumidControl_CoolReheat = 2

! Coil type for SimWater and SimSteamCoil
INTEGER, PARAMETER :: CoolingCoil               = 0
INTEGER, PARAMETER :: HeatingCoil               = 1
INTEGER, PARAMETER :: SuppHeatCoil              = 2

! Supply Air Sizing Option
INTEGER, PARAMETER :: None                            = 1
INTEGER, PARAMETER :: SupplyAirFlowRate               = 2
INTEGER, PARAMETER :: FlowPerFloorArea                = 3
INTEGER, PARAMETER :: FractionOfAutosizedCoolingValue = 4
INTEGER, PARAMETER :: FractionOfAutosizedHeatingValue = 5
INTEGER, PARAMETER :: FlowPerCoolingCapacity          = 6
INTEGER, PARAMETER :: FlowPerHeatingCapacity          = 7

! Airflow control for contant fan mode
INTEGER, PARAMETER :: UseCompressorOnFlow  = 1 ! set compressor OFF air flow rate equal to compressor ON air flow rate
INTEGER, PARAMETER :: UseCompressorOffFlow = 2 ! set compressor OFF air flow rate equal to user defined value

! System Control Type
INTEGER, PARAMETER :: LoadBased     = 1 ! control system based on zone load
INTEGER, PARAMETER :: SetPointBased = 2 ! control system based on coil set point manager

CHARACTER(len=*), PARAMETER :: Blank = ' '

  ! DERIVED TYPE DEFINITIONS
TYPE DesignSpecMSHPData
  CHARACTER(len=MaxNameLength) :: Name =' '                    ! Name of the design specification MSHP
  INTEGER  :: NumOfSpeedCooling         = 0                    ! The number of speeds for cooling
  INTEGER  :: NumOfSpeedHeating         = 0                    ! The number of speeds for heating
  REAL(R64), DIMENSION(:), ALLOCATABLE :: CoolingVolFlowRatio  ! The ratio of flow to max for this speed
  REAL(R64), DIMENSION(:), ALLOCATABLE :: HeatingVolFlowRatio  ! The ratio of flow to max for this speed
END TYPE DesignSpecMSHPData

TYPE UnitarySystemData
! HVAC system specific data
  CHARACTER(len=MaxNameLength) :: UnitarySystemType  = ' '     ! Type of Unitary System
  INTEGER    :: UnitarySystemType_Num                = 0       ! integer type of Unitary System
  CHARACTER(len=MaxNameLength) :: Name               = ' '     ! Name of the Unitary System
  LOGICAL    :: HeatPump                             = .FALSE. ! TRUE if both cooling and heating coils are DX
  INTEGER    :: SysAvailSchedPtr                     = 0       ! System Availability schedule
  INTEGER    :: UnitarySystemInletNodeNum            = 0       ! Parent inlet node number
  INTEGER    :: UnitarySystemOutletNodeNum           = 0       ! Parent outlet node number
  INTEGER    :: CondenserType                        = 0       ! type of condenser (AirCooled, EvapCooled, WaterCooled)
  LOGICAL    :: AirLoopEquipment                     = .TRUE.  ! identifies that this system is part of an air loop
  INTEGER    :: ControlZoneNum                       = 0       ! Index to controlled zone
  INTEGER    :: ZoneSequenceCoolingNum               = 0       ! Index to cooling sequence/priority for this zone
  INTEGER    :: ZoneSequenceHeatingNum               = 0       ! Index to heating sequence/priority for this zone
  INTEGER    :: NodeNumofControlledZone              = 0       ! Node number of controlled zone
  INTEGER    :: ZoneInletNode                        = 0       ! Zone inlet node number in the controlled zone
  REAL(r64)  :: ControlZoneMassFlowFrac              = 0.0d0   ! Fraction of flow to control zone
  LOGICAL    :: Humidistat                           = .FALSE. ! Set to True if dehumidification control mode is set to
  REAL(r64)  :: DesignMaxOutletTemp                  = 80.0d0  ! Maximum supply air temperature from heater [C]
  INTEGER    :: CondenserNodeNum                     = 0       ! index to condenser air inlet node
  INTEGER    :: DehumidControlType_Num               = 0       ! Set to Dehumid Control None, CoolReheat or MultiMode
  INTEGER    :: AirFlowControl                       = 1       ! UseCompressorOnFlow or UseCompressorOffFlow
  INTEGER    :: ControlType                          = 0       ! Setpoint or Load based control
  LOGICAL    :: RequestAutosize                      = .FALSE. ! determines if inputs need autosizing
  LOGICAL    :: RunOnSensibleLoad                    = .TRUE.  ! logical determines if this system will run to
  LOGICAL    :: RunOnLatentLoad                      = .FALSE. ! logical determines if this system will run to
  LOGICAL    :: RunOnLatentOnlyWithSensible          = .FALSE. ! allow latent dehumidification only if sensible load exists
  INTEGER    :: DehumidificationMode                 = 0       ! Dehumidification mode for multimode coil,
                                                               ! 0=normal, 1+=enhanced dehumidification mode
  INTEGER    :: FanOpMode                            = 0       ! Fan operating mode (see parameter above)
  INTEGER    :: LastMode                             = 0       ! last mode of operation, coolingmode or heatingmode
  REAL(r64)  :: AncillaryOnPower                    = 0.0d0    ! Ancillary On-Cycle Electric Power [W]
  REAL(r64)  :: AncillaryOffPower                   = 0.0d0    ! Ancillary Off-Cycle Electric Power [W]

  CHARACTER(len=MaxNameLength) :: DesignSpecMultispeedHPType = ' '  ! Object type for specifying multispeed flow rates
  CHARACTER(len=MaxNameLength) :: DesignSpecMultispeedHPName = ' '  ! Object name for specifying multispeed flow rates

! Cooling coil specific data
  CHARACTER(len=MaxNameLength) :: CoolingCoilName   = ' '      ! coil name (eliminate after blank is accepted in CALL)
  INTEGER    :: CoolingCoilType_Num                 = 0        ! numeric coil type
  INTEGER    :: CoolingCoilIndex                    = 0        ! index to specific cooling coil
  REAL(r64)  :: DesignCoolingCapacity               = 0.0d0    ! cooling coil capacity (W)
  INTEGER    :: CoolingCoilAvailSchPtr              = 0        ! cooling coil availability schedule index
  INTEGER    :: ActualDXCoilIndexForHXAssisted      = 0        ! index to DX coil used in HX assisted object
  REAL(r64)  :: DOASDXCoolingCoilMinTout            = 0.0d0    ! DOAS DX Cooling coil outlet air minimum temperature
  LOGICAL    :: ISHundredPercentDOASDXCoil          = .FALSE.  ! logical determines if this system will run as 100% DOAS
  LOGICAL    :: CoolCoilExists                      = .FALSE.  ! True if a cooling coil is specified in the unitary system
  INTEGER    :: FrostControlStatus                  = 0        ! DOAS coil system frost control status
  INTEGER    :: CoolCoilInletNodeNum                = 0        ! Cooling coil air inlet node number
  INTEGER    :: CoolCoilOutletNodeNum               = 0        ! Cooling coil air outlet node number
  INTEGER    :: CoolCoilFluidOutletNodeNum          = 0        ! Cooling coil fluid outlet node number (from Plant Loop data)
  INTEGER    :: CoolCoilLoopNum                     = 0        ! Plant loop num of chilled water coil
  INTEGER    :: CoolCoilLoopSide                    = 0        ! Supply side or demand side
  INTEGER    :: CoolCoilBranchNum                   = 0        ! Branch of number of the cooling coil in the plant loop
  INTEGER    :: CoolCoilCompNum                     = 0        ! Comp num of the cooling coil in the plant loop
  INTEGER    :: CoolCoilFluidInletNode              = 0        ! Cooling coil fluid inlet node
  REAL(r64)  :: MaxCoolCoilFluidFlow                = Autosize ! Maximum cooling coil fluid flow for chilled water coil
  LOGICAL    :: CoolingCoilUpStream                 = .TRUE.   ! Set to true when coolign coil is upstream in the unitary system
  REAL(R64)  :: CoolCompPartLoadRatio               = 0.0d0    ! Unitary system compressor part load ratio in cooling

! Heating coil specific data
  CHARACTER(len=MaxNameLength) :: HeatingCoilName   =' '       ! coil name (eliminate after blank is accepted in CALL)
  INTEGER    :: HeatingCoilType_Num                 = 0        ! numeric coil type
  INTEGER    :: HeatingCoilIndex                    = 0        ! index to specific heating coil
  REAL(r64)  :: DesignHeatingCapacity               = 0.0d0    ! heating coil capacity (W)
  REAL(r64)  :: HeatingSizingRatio                  = 1.0d0    ! ratio of heating coil to cooling coil size
  LOGICAL    :: DXHeatingCoil                       = .FALSE.  ! specifies if heating coil is DX
  INTEGER    :: HeatCoilInletNodeNum                = 0        ! Heating coil air inlet node number
  INTEGER    :: HeatCoilOutletNodeNum               = 0        ! Heating coil air outlet node number
  INTEGER    :: HeatCoilFluidOutletNodeNum          = 0        ! Heating coil fluid outlet node number (from Plant Loop data)
  INTEGER    :: HeatingCoilPLFCurveIndex            = 0        ! PLF curve index (not used yet?)
  INTEGER    :: HeatingCoilAvailSchPtr              = 0        ! heating coil availability schedule index
  LOGICAL    :: HeatCoilExists                      = .FALSE.  ! True if a heating coil is specified in the unitary system
  INTEGER    :: HeatCoilLoopNum                     = 0        ! Plant loop num of hot water or steam coil
  INTEGER    :: HeatCoilLoopSide                    = 0        ! Supply side or demand side
  INTEGER    :: HeatCoilBranchNum                   = 0        ! Branch of number of the heating coil in the plant loop
  INTEGER    :: HeatCoilCompNum                     = 0        ! Comp num of the heating coil in the plant loop
  INTEGER    :: HeatCoilFluidInletNode              = 0        ! Heating coil fluid inlet node
  REAL(r64)  :: MaxHeatCoilFluidFlow                = Autosize ! Maximum heating coil fluid flow for hot water or steam coil
  REAL(R64)  :: HeatCompPartLoadRatio               = 0.0d0    ! Unitary system compressor part load ratio in heating

! Supplemental heating coil specific data
  CHARACTER(len=MaxNameLength) :: SuppHeatCoilName  = ' '      ! coil name (eliminate after blank is accepted in CALL)
  INTEGER    :: SuppHeatCoilType_Num                = 0        ! numeric coil type
  INTEGER    :: SuppHeatCoilIndex                   = 0        ! index to specific supplemental heating coil
  REAL(r64)  :: DesignSuppHeatingCapacity           = 0.0d0    ! supplemental heating coil capacity (W)
  INTEGER    :: SuppCoilFluidInletNode              = 0        ! supplemental heating coil water/steam inlet node
  INTEGER    :: SuppCoilFluidOutletNodeNum          = 0        ! Supplemental coil fluid outlet node number (from Plant Loop data)
  INTEGER    :: SuppCoilAirInletNode                = 0        ! supplemental heating coil air inlet node
  INTEGER    :: SuppCoilAirOutletNode               = 0        ! supplemental heating coil air outlet node
  INTEGER    :: SuppCoilAvailSchPtr                 = 0        ! supplemental heating coil availability schedule index
  REAL(r64)  :: MaxSuppCoilFluidFlow                = Autosize ! supplemental heating coil maximum water/steam flow rate (m3/s)
  REAL(r64)  :: MaxOATSuppHeat                      = 21.0d0   ! Maximum outdoor dry-bulb temperature for supplemental coil [C]
  LOGICAL    :: SuppCoilExists                      = .FALSE.  ! True if a supp coil is specified in the unitary system
  INTEGER    :: SuppCoilLoopNum                     = 0        ! Plant loop num of supplemental coil
  INTEGER    :: SuppCoilLoopSide                    = 0        ! Supply side or demand side
  INTEGER    :: SuppCoilBranchNum                   = 0        ! Branch of number of the supplemental coil in the plant loop
  INTEGER    :: SuppCoilCompNum                     = 0        ! Comp num of the supplemental coil in the plant loop

! fan specific data
  INTEGER    :: FanType_Num                         = 0        ! Fan type num i.e. OnOff, ConstVol, VAV
  INTEGER    :: FanIndex                            = 0        ! index of fan of a particular type
  REAL(r64)  :: ActualFanVolFlowRate                = 0.0d0    ! Actual or design fan volume flow rate
  INTEGER    :: FanOpModeSchedPtr                   = 0        ! fan operating mode schedule pointer
  INTEGER    :: FanAvailSchedPtr                    = 0        ! fan availability schedule pointer
  INTEGER    :: FanPlace                            = 0        ! Blow through or DrawThrough Fan
  LOGICAL    :: FanExists                           = .FALSE.  ! True if a fan is specified in the unitary system
  REAL(r64)  :: FanDelayTime                        = 0.0d0    ! Fan delay time, time delay for the HP's fan to
                                                               ! shut off after compressor cycle off [s]
! air flow variables
  REAL(r64)  :: MaxCoolAirVolFlow                   = 0.0d0    ! Maximum coil air volumetric flow for cooling [m3/s]
  REAL(r64)  :: MaxHeatAirVolFlow                   = 0.0d0    ! Maximum coil air volumetric flow for heating [m3/s]
  REAL(r64)  :: MaxNoCoolHeatAirVolFlow             = 0.0d0    ! Maximum coil air volumetric flow for no cooling or heating [m3/s]
  REAL(r64)  :: DesignFanVolFlowRate                = 0.0d0    ! Design fan volume flow rate [m3/s]
  REAL(r64)  :: DesignMassFlowRate                  = 0.0d0    ! Design mass flow rate [m3/s]
  REAL(r64)  :: MaxCoolAirMassFlow                  = 0.0d0    ! Maximum coil air mass flow for cooling [kg/s]
  REAL(r64)  :: MaxHeatAirMassFlow                  = 0.0d0    ! Maximum coil air mass flow for heating [kg/s]
  REAL(r64)  :: MaxNoCoolHeatAirMassFlow            = 0.0d0    ! Maximum coil air mass flow for no cooling or heating [kg/s]
  INTEGER    :: CoolingSAFMethod                    = 0        ! Supply air flow method for cooling
  INTEGER    :: HeatingSAFMethod                    = 0        ! Supply air flow method for heating
  INTEGER    :: NoCoolHeatSAFMethod                 = 0        ! Supply air flow method for no cooling or heating

! Heat pump related specific data
  REAL(r64)  :: MinOATCompressor                    = 0.0d0    ! Minimum outdoor temperature below which compressor if off
  REAL(r64)  :: MaxONOFFCyclesperHour               = 0.0d0    ! Maximum cycling rate of unitary system [cycles/hr]
  REAL(r64)  :: HPTimeConstant                      = 0.0d0    ! Heat pump time constant [s]
  REAL(r64)  :: OnCyclePowerFraction                = 0.0d0    ! Fraction of on-cycle power use [~]
  REAL(r64)  :: DesignHRWaterVolumeFlow             = 0.0d0    ! Design water volume flow rate through heat recovery loop [m3/s]
  REAL(R64)  :: WSHPRuntimeFrac                     = 0.0d0    ! Runtime fraction of water source heat pump
  REAL(R64)  :: HeatingCoilSensDemand               = 0.0d0         ! Sensible demand on Heating Coil [W]
  REAL(R64)  :: CoolingCoilSensDemand               = 0.0d0         ! Sensible demand on Cooling Coil [W]
  REAL(R64)  :: CoolingCoilLatentDemand             = 0.0d0         ! Latent demand on Cooling Coil [W]

! Heat recovery related specific data
  INTEGER    :: HeatRecoveryInletNodeNum            = 0        ! Node number on heat recovery water inlet
  INTEGER    :: HeatRecoveryOutletNodeNum           = 0        ! Node number on heat recovery water outlet
  LOGICAL    :: HeatRecActive                       = .FALSE.  ! True when entered Heat Rec Vol Flow Rate > 0
  REAL(r64)  :: DesignHeatRecMassFlowRate           = 0.0d0    ! Design water mass flow rate through heat recovery loop [kg/s]
  REAL(r64)  :: MaxHROutletWaterTemp                = 0.0d0    ! Maximum outlet water temperature for heat recovery [C]
  INTEGER    :: HRLoopNum                           = 0        ! plant loop number for heat recovery
  INTEGER    :: HRLoopSideNum                       = 0        ! Plant loop side (supply or demand) for heat recovery
  INTEGER    :: HRBranchNum                         = 0        ! plant loop branch for heat recovery
  INTEGER    :: HRCompNum                           = 0        ! plant loop component for heat recovery

! set point based control varibles
  INTEGER    :: SystemHeatControlNodeNum            = 0        ! the node number of the node with the setpoint
  INTEGER    :: SystemCoolControlNodeNum            = 0        ! the node number of the node with the setpoint
  INTEGER    :: SuppHeatControlNodeNum              = 0        ! the node number of the node with the setpoint
  REAL(r64)  :: DesiredOutletTemp                   = 0.0d0    ! the setpoint temperature at the unit outlet node
  REAL(r64)  :: DesiredOutletHumRat                 = 1.0d0    ! the setpoint humidity ratio at the unit outlet node

! operational system variables
  REAL(r64)  :: CoolingPartLoadFrac                 = 0.0d0    ! part load cooling fraction for current timestep
  REAL(r64)  :: HeatingPartLoadFrac                 = 0.0d0    ! part load heating fraction for current timestep
  REAL(r64)  :: SuppHeatPartLoadFrac                = 0.0d0    ! part load supp heating fraction for current timestep
  REAL(r64)  :: SupHeaterLoad                       = 0.0d0    ! Supplemental Heat Load for current timestep
  REAL(r64)  :: SenLoadLoss                         = 0.0d0    ! Air distribution system sensible loss [W]
  REAL(r64)  :: LatLoadLoss                         = 0.0d0    ! Air distribution system latent loss [W]
  REAL(r64)  :: SensibleLoadMet                     = 0.0d0    ! System sensible load [W]
  REAL(r64)  :: LatentLoadMet                       = 0.0d0    ! System latent load [W]
  LOGICAL    :: InitHeatPump                        = .TRUE.   ! Heat pump initialization flag (for error reporting)
  INTEGER    :: WaterCyclingMode                    = 0        ! Heat Pump Coil water flow mode; See def in DataHVACGlobals,
                                                               ! 1=water cycling, 2=water constant, 3=water constant on demand

! start of additional varibles for variable speed water source heat pump
  INTEGER   :: HeatCoolMode                         = 0        ! System operating mode (0 = floating, 1 = cooling, 2 = heating)
  INTEGER   :: NumOfSpeedCooling                    = 0        ! The number of speeds for cooling
  INTEGER   :: NumOfSpeedHeating                    = 0        ! The number of speeds for heating
  REAL(r64) :: IdleSpeedRatio                       = 0        ! idle air fan ratio
  REAL(r64) :: IdleVolumeAirRate                    = 0        ! idle air flow rate [m3/s]
  REAL(r64) :: IdleMassFlowRate                     = 0        ! idle air flow rate [kg/s]
  LOGICAL   :: CheckFanFlow                         = .TRUE.   ! Supply airflow check
  REAL(r64), DIMENSION(:), ALLOCATABLE :: HeatVolumeFlowRate   ! Supply air volume flow rate during heating operation
  REAL(r64), DIMENSION(:), ALLOCATABLE :: HeatMassFlowRate     ! Supply air mass flow rate during heating operation
  REAL(r64), DIMENSION(:), ALLOCATABLE :: CoolVolumeFlowRate   ! Supply air volume flow rate during cooling operation
  REAL(r64), DIMENSION(:), ALLOCATABLE :: CoolMassFlowRate     ! Supply air mass flow rate during cooling operation
  REAL(r64), DIMENSION(:), ALLOCATABLE :: MSHeatingSpeedRatio  ! Fan speed ratio in heating mode
  REAL(r64), DIMENSION(:), ALLOCATABLE :: MSCoolingSpeedRatio  ! Fan speed ratio in cooling mode
  REAL(r64) :: NoHeatCoolSpeedRatio                 = 1.0d0    ! Fan speed ratio when no cooling or heating
  INTEGER   :: DesignSpecMSHPIndex                  = 0        ! Index to design specification multispeed heat pump object
  LOGICAL   :: MultiSpeedCoolingCoil                = .FALSE.  ! TRUE when cooling coil multispeed
  LOGICAL   :: MultiSpeedHeatingCoil                = .FALSE.  ! TRUE when heating coil multispeed
  LOGICAL   :: VarSpeedCoolingCoil                  = .FALSE.  ! TRUE when cooling coil variable speed
  LOGICAL   :: VarSpeedHeatingCoil                  = .FALSE.  ! TRUE when heating coil variable speed
  INTEGER   :: CoolingSpeedNum                      = 0        ! speed number for multispeed cooling coils types
  INTEGER   :: HeatingSpeedNum                      = 0        ! speed number for multispeed heating coils types
  REAL(r64) :: CoolingSpeedRatio                    = 1.0d0    ! current compressor speed ratio (variable speed)
  REAL(r64) :: CoolingFanSpeedRatio                 = 1.0d0    ! current fan speed ratio
  REAL(r64) :: HeatingSpeedRatio                    = 1.0d0    ! current compressor speed ratio (variable speed)
  REAL(r64) :: HeatingFanSpeedRatio                 = 1.0d0    ! current fan speed ratio
  REAL(r64) :: CoolingCycRatio                      = 0.0d0    ! cycling part load ratio (variable speed)
  REAL(r64) :: HeatingCycRatio                      = 0.0d0    ! cycling part load ratio (variable speed)
 ! end of additional variables for variable speed water source heat pump

! Report Varibles
  REAL(r64)    :: PartLoadFrac                     = 0.0d0     ! part load fraction for current time step (single speed)
  REAL(R64)    :: FanPartLoadRatio                 = 0.0d0     ! Unitary system fan part load ratio
  REAL(R64)    :: CompPartLoadRatio                = 0.0d0     ! Unitary system compressor part load ratio
  REAL(R64)    :: ElecPower                        = 0.0d0     ! Unitary System Electric Power
  REAL(R64)    :: ElecPowerConsumption             = 0.0d0     ! Electricity power comsumption: CondenserFan+CCHeater+Defrost+aux
  REAL(r64)    :: TotCoolEnergyRate                = 0.0d0     ! Unitary System Total Cooling Rate [W]
  REAL(r64)    :: SensCoolEnergyRate               = 0.0d0     ! Unitary System Sensible Cooling Rate [W]
  REAL(r64)    :: LatCoolEnergyRate                = 0.0d0     ! Unitary System Latent Cooling Rate [W]
  REAL(r64)    :: TotHeatEnergyRate                = 0.0d0     ! Unitary System Total Heating Rate [W]
  REAL(r64)    :: SensHeatEnergyRate               = 0.0d0     ! Unitary System Sensible Heating Rate [W]
  REAL(r64)    :: LatHeatEnergyRate                = 0.0d0     ! Unitary System Latent Heating Rate [W]
  REAL(r64)    :: TotalAuxElecPower                = 0.0d0     ! Unitary System Ancillary Electric Power [W]
  REAL(r64)    :: HeatingAuxElecConsumption        = 0.0d0     ! Unitary System Heating Ancillary Electric Energy [J]
  REAL(r64)    :: CoolingAuxElecConsumption        = 0.0d0     ! Unitary System Cooling Ancillary Electric Energy [J]
  REAL(r64)    :: HeatRecoveryRate                 = 0.0d0     ! Unitary System Heat Recovery Rate [W]
  REAL(r64)    :: HeatRecoveryEnergy               = 0.0d0     ! Unitary System Heat Recovery Energy [J]
  REAL(r64)    :: HeatRecoveryInletTemp            = 0.0d0     ! Unitary System Heat Recovery Inlet Temperature [C]
  REAL(r64)    :: HeatRecoveryOutletTemp           = 0.0d0     ! Unitary System Heat Recovery Outlet Temperature [C]
  REAL(r64)    :: HeatRecoveryMassFlowRate         = 0.0d0     ! Unitary System Heat Recovery Fluid Mass Flow Rate [kg/s]
  REAL(r64)    :: DehumidInducedHeatingDemandRate  = 0.0d0     ! Unitary System
  REAL(r64)    :: EMSSensibleZoneLoadValue         = 0.0d0     ! Value EMS is directing to use
  REAL(r64)    :: EMSMoistureZoneLoadValue         = 0.0d0     ! Value EMS is directing to use
  INTEGER      :: SpeedNum                         = 0         ! speed number of active multi- or variable-speed coil
  REAL(r64)    :: SpeedRatio                       = 0.0d0     ! current compressor speed ratio (variable speed)
  REAL(r64)    :: CycRatio                         = 0.0d0     ! cycling part load ratio (variable speed)

! Warning message variables
  INTEGER      :: HXAssistedSensPLRIter                = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedSensPLRIterIndex           = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedSensPLRFail                = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedSensPLRFailIndex           = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedSensPLRFail2               = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedSensPLRFailIndex2          = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedLatPLRIter                 = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedLatPLRIterIndex            = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedLatPLRFail                 = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedLatPLRFailIndex            = 0     ! used in HX Assisted calculations

  INTEGER      :: HXAssistedCRLatPLRIter               = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedCRLatPLRIterIndex          = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedCRLatPLRFail               = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedCRLatPLRFailIndex          = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedCRLatPLRFail2              = 0     ! used in HX Assisted calculations
  INTEGER      :: HXAssistedCRLatPLRFailIndex2         = 0     ! used in HX Assisted calculations

  INTEGER      :: SensPLRIter                          = 0     ! used in cool coil calculations
  INTEGER      :: SensPLRIterIndex                     = 0     ! used in cool coil calculations
  INTEGER      :: SensPLRFail                          = 0     ! used in cool coil calculations
  INTEGER      :: SensPLRFailIndex                     = 0     ! used in cool coil calculations
  INTEGER      :: LatPLRIter                           = 0     ! used in cool coil calculations
  INTEGER      :: LatPLRIterIndex                      = 0     ! used in cool coil calculations
  INTEGER      :: LatPLRFail                           = 0     ! used in cool coil calculations
  INTEGER      :: LatPLRFailIndex                      = 0     ! used in cool coil calculations

  INTEGER      :: HeatCoilSensPLRIter                  = 0     ! used in heat coil calculations
  INTEGER      :: HeatCoilSensPLRIterIndex             = 0     ! used in heat coil calculations
  INTEGER      :: HeatCoilSensPLRFail                  = 0     ! used in heat coil calculations
  INTEGER      :: HeatCoilSensPLRFailIndex             = 0     ! used in heat coil calculations

  INTEGER      :: SuppHeatCoilSensPLRIter              = 0     ! used in supp heat coil calculations
  INTEGER      :: SuppHeatCoilSensPLRIterIndex         = 0     ! used in supp heat coil calculations
  INTEGER      :: SuppHeatCoilSensPLRFail              = 0     ! used in supp heat coil calculations
  INTEGER      :: SuppHeatCoilSensPLRFailIndex         = 0     ! used in supp heat coil calculations

  INTEGER      :: DXCoilSensPLRIter                    = 0     ! used in DXCoil calculations
  INTEGER      :: DXCoilSensPLRIterIndex               = 0     ! used in DXCoil calculations
  INTEGER      :: DXCoilSensPLRFail                    = 0     ! used in DXCoil calculations
  INTEGER      :: DXCoilSensPLRFailIndex               = 0     ! used in DXCoil calculations

  INTEGER      :: MSpdSensPLRIter                      = 0     ! used in MultiSpeed calculations
  INTEGER      :: MSpdSensPLRIterIndex                 = 0     ! used in MultiSpeed calculations
  INTEGER      :: MSpdCycSensPLRIter                   = 0     ! used in MultiSpeed calculations
  INTEGER      :: MSpdCycSensPLRIterIndex              = 0     ! used in MultiSpeed calculations
  INTEGER      :: MSpdLatPLRIter                       = 0     ! used in MultiSpeed calculations
  INTEGER      :: MSpdLatPLRIterIndex                  = 0     ! used in MultiSpeed calculations
  INTEGER      :: MSpdCycLatPLRIter                    = 0     ! used in MultiSpeed calculations
  INTEGER      :: MSpdCycLatPLRIterIndex               = 0     ! used in MultiSpeed calculations

  INTEGER      :: MaxIterIndex                         = 0     ! used in PLR calculations for sensible load
  INTEGER      :: RegulaFalsIFailedIndex               = 0     ! used in PLR calculations for sensible load
  INTEGER      :: LatMaxIterIndex                      = 0     ! used in PLR calculations for moisture load
  INTEGER      :: LatRegulaFalsIFailedIndex            = 0     ! used in PLR calculations for moisture load

! EMS variables
  LOGICAL      :: DesignFanVolFlowRateEMSOverrideOn       = .FALSE. ! If true, then EMS is calling to override autosize fan flow
  LOGICAL      :: MaxHeatAirVolFlowEMSOverrideOn          = .FALSE. ! If true, then EMS is calling to override autosize fan flow
  LOGICAL      :: MaxCoolAirVolFlowEMSOverrideOn          = .FALSE. ! If true, then EMS is calling to override autosize fan flow
  LOGICAL      :: MaxNoCoolHeatAirVolFlowEMSOverrideOn    = .FALSE. ! If true, then EMS is calling to override autosize fan flow
  REAL(r64)    :: DesignFanVolFlowRateEMSOverrideValue    = 0.0d0   ! EMS value for override of fan flow rate autosize [m3/s]
  REAL(r64)    :: MaxHeatAirVolFlowEMSOverrideValue       = 0.0d0   ! EMS value for override of fan flow rate autosize [m3/s]
  REAL(r64)    :: MaxCoolAirVolFlowEMSOverrideValue       = 0.0d0   ! EMS value for override of fan flow rate autosize [m3/s]
  REAL(r64)    :: MaxNoCoolHeatAirVolFlowEMSOverrideValue = 0.0d0   ! EMS value for override of fan flow rate autosize [m3/s]
  LOGICAL      :: EMSOverrideSensZoneLoadRequest          = .FALSE. ! If true, then EMS is calling to override zone load
  LOGICAL      :: EMSOverrideMoistZoneLoadRequest         = .FALSE. ! If true, then EMS is calling to override zone load

! Staged thermostat control
  Integer      :: StageNum                             = 0     ! Stage number specified by staged thermostat
  LOGICAL      :: Staged                               = .FALSE.  ! Using Staged thermostat
  INTEGER      :: CoolCountAvail                       = 0     ! Counter used to minimize the occurrence of output warnings
  INTEGER      :: CoolIndexAvail                       = 0     ! Index used to minimize the occurrence of output warnings
  INTEGER      :: HeatCountAvail                       = 0     ! Counter used to minimize the occurrence of output warnings
  INTEGER      :: HeatIndexAvail                       = 0     ! Index used to minimize the occurrence of output warnings

END TYPE UnitarySystemData

!MODULE VARIABLE DECLARATIONS:
LOGICAL,SAVE :: GetInputFlag              = .TRUE.     ! Flag to get input only once
LOGICAL      :: EconomizerFlag            = .FALSE.    ! holds air loop economizer status
LOGICAL      :: HeatingLoad               = .FALSE.    ! True when zone needs heating
LOGICAL      :: CoolingLoad               = .FALSE.    ! True when zone needs cooling
REAL(r64)    :: MoistureLoad              = 0.0d0      ! Dehumidification Load (W)
LOGICAL      :: SuppHeatingCoilFlag       = .FALSE.    ! set to TRUE when simulating supplemental heating coil
INTEGER      :: NumUnitarySystem          = 0          ! The Number of Unitary Systems found in the Input
INTEGER      :: NumDesignSpecMultiSpeedHP = 0          ! The number of design specification objects for MSHP
REAL(r64)    :: CompOnMassFlow            = 0.0d0      ! Supply air mass flow rate w/ compressor ON [kg/s]
REAL(r64)    :: CompOffMassFlow           = 0.0d0      ! Supply air mass flow rate w/ compressor OFF [kg/s]
REAL(r64)    :: CompOnFlowRatio           = 0.0d0      ! fan flow ratio when coil on
REAL(r64)    :: CompOffFlowRatio          = 0.0d0      ! fan flow ratio when coil off
REAL(r64)    :: FanSpeedRatio             = 0.0d0      ! ratio of air flow ratio passed to fan object
REAL(r64)    :: CoolHeatPLRRat            = 1.0d0      ! ratio of cooling to heating PLR, used for cycling fan RH control
REAL(r64)    :: OnOffAirFlowRatioSave     = 0.0d0      ! Saves the OnOffAirFlowRatio calculated in RegulaFalsi calls.
REAL(R64)    :: QToCoolSetPt              = 0.0d0      ! load to cooling set point {W}
REAL(R64)    :: QToHeatSetPt              = 0.0d0      ! load to heating set point {W}
REAL(r64)    :: TempSteamIn               = 100.0d0    !  steam coil steam inlet temperature

! Allocatable types
TYPE (DesignSpecMSHPData), ALLOCATABLE, DIMENSION(:) :: DesignSpecMSHP
TYPE (UnitarySystemData),  ALLOCATABLE, DIMENSION(:) :: UnitarySystem
LOGICAL, ALLOCATABLE, DIMENSION(:)                   :: CheckEquipName
LOGICAL, ALLOCATABLE, DIMENSION(:)   :: MultiOrVarSpeedHeatCoil
LOGICAL, ALLOCATABLE, DIMENSION(:)   :: MultiOrVarSpeedCoolCoil

! Subroutine Specifications for the Module
          ! Driver/Manager Routines
PUBLIC  SimUnitarySystem

          ! Initialization routines
PRIVATE InitUnitarySystems
PRIVATE UpdateUnitarySystemControl
PRIVATE InitLoadBasedControl
PRIVATE SizeUnitarySystem

          ! Get Input routines
PRIVATE GetUnitarySystemInput

          ! Control routines to find PLR, check convergence and update nodes
PRIVATE ControlUnitarySystemtoSP   ! simulates set point based control
PRIVATE ControlUnitarySystemtoLoad ! simulates load based control
PRIVATE ControlUnitarySystemOutput ! simulate system to find operating output
PRIVATE ControlCoolingSystem       ! control cooling system to set point
PRIVATE ControlHeatingSystem       ! control heating system to set point
PRIVATE ControlSuppHeatSystem      ! control supplemental heating system to set point

          ! Calc routines to simulate each child component in order

          ! set point based calc routine
PRIVATE CalcUnitarySuppSystemtoSP
          ! Load based calc routine
PRIVATE CalcUnitarySystemToLoad

PRIVATE CalcUnitaryCoolingSystem
PRIVATE CalcUnitaryHeatingSystem
PRIVATE CalcUnitarySuppHeatingSystem
PRIVATE CalcPassiveSystem

          ! Airflow control routines
PRIVATE SetOnOffMassFlowRate  ! sets CompOnMassFlow and CompOffMassFlow
PRIVATE SetAverageAirFlow     ! sets inlet node mass flow rate based on PLR

PRIVATE SetSpeedVariables ! sets speed ratio, cycling ratio, RTF etc for different models

          ! Verify set point exists for SetPointBased control
PRIVATE CheckNodeSetPoint
          ! Heat recovery subroutine
PRIVATE UnitarySystemHeatRecovery
          ! Reporting routines for module
PRIVATE ReportUnitarySystem

          ! RegulaFalsi routines
! ** RAR I'd rather see a SELECT CASE in 1 or 2 generic routines instead of one for each coil type
PRIVATE DXCoilVarSpeedResidual         ! converges on outlet air set point temperature
PRIVATE DXCoilVarSpeedHumRatResidual   ! converges on outlet air set point humidity ratio
PRIVATE DXCoilCyclingResidual          ! converges on outlet air set point temperature
PRIVATE DXCoilCyclingHumRatResidual    ! converges on outlet air set point humidity ratio
PRIVATE DOE2DXCoilResidual             ! converges on outlet air set point temperature
PRIVATE DOE2DXCoilHumRatResidual       ! converges on outlet air set point humidity ratio
PRIVATE DXHeatingCoilResidual          ! converges on outlet air set point temperature
PRIVATE HeatingCoilVarSpeedResidual    ! converges on outlet air set point temperature
PRIVATE HeatingCoilVarSpeedCycResidual ! converges on outlet air set point temperature
PRIVATE MultiModeDXCoilResidual        ! converges on outlet air set point temperature
PRIVATE MultiModeDXCoilHumRatResidual  ! converges on outlet air set point humidity ratio
PRIVATE HXAssistedCoolCoilTempResidual ! converges on outlet air set point temperature
PRIVATE HXAssistedCoolCoilHRResidual   ! converges on outlet air set point humidity ratio
PRIVATE HotWaterHeatingCoilResidual    ! converges on outlet air set point temperature
PRIVATE GasElecHeatingCoilResidual     ! converges on outlet air set point temperature
PRIVATE SteamHeatingCoilResidual       ! converges on outlet air set point temperature
PRIVATE CoolWaterTempResidual          ! converges on outlet air set point temperature
PRIVATE CoolWaterHumRatResidual        ! converges on outlet air set point temperature

PRIVATE CalcUnitarySystemLoadResidual  ! converges on load to be met

PRIVATE CoolWatertoAirHPTempResidual   ! converges on outlet air set point temperature
PRIVATE HeatWatertoAirHPTempResidual   ! converges on outlet air set point temperature
PRIVATE HeatPumpRunFrac                ! calculates RTF based on PLR
PRIVATE SimMultiSpeedCoils             ! simulates multispeed coil types
PRIVATE SimWaterCoils                  ! simulates water coils
PRIVATE SimSteamCoils                  ! simulates steam coils
PRIVATE FrostControlSetPointLimit      ! frost control routine for 100% OA DX coils
PRIVATE GetUnitarySystemDXCoolingCoilIndex ! finds cool coil index in other UnitarySystem objects
PUBLIC  CheckUnitarySysCoilInOASysExists   ! check if UnitarySystem is on OA system
PUBLIC  GetUnitarySystemOAHeatCoolCoil     ! Logical returns if coil is in OA system

CONTAINS

! MODULE SUBROUTINES:
!*************************************************************************
SUBROUTINE SimUnitarySystem(UnitarySystemName,FirstHVACIteration,AirLoopNum,CompIndex, &
                            HeatActive,CoolActive,OAUnitNum,OAUCoilOutTemp,ZoneEquipment)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine manages unitary system component simulation.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE General,          ONLY: TrimSigDigits
  USE DataAirLoop,      ONLY: AirLoopControlInfo
  USE InputProcessor,   ONLY: FindItemInList

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  CHARACTER(len=*), INTENT(IN)       :: UnitarySystemName  ! Name of Unitary System object
  LOGICAL,   INTENT(IN)              :: FirstHVACIteration ! True when first HVAC iteration
  INTEGER,   INTENT(IN)              :: AirLoopNum         ! Primary air loop number
  INTEGER,   INTENT(INOUT)           :: CompIndex          ! Index to Unitary System object
  LOGICAL,   INTENT(OUT),   OPTIONAL :: HeatActive         ! True if heat coil active
  LOGICAL,   INTENT(OUT),   OPTIONAL :: CoolActive         ! True if cool coil active
  INTEGER,   INTENT(IN),    OPTIONAL :: OAUnitNum          ! If the system is an equipment of OutdoorAirUnit
  REAL(r64), INTENT(IN),    OPTIONAL :: OAUCoilOutTemp     ! the coil inlet temperature of OutdoorAirUnit
  LOGICAL,   INTENT(IN),    OPTIONAL :: ZoneEquipment      ! TRUE if called as zone equipment

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER       :: UnitarySysNum         ! Index to AirloopHVAC:UnitarySystem object
  LOGICAL       :: HXUnitOn              ! Flag to control HX for HXAssisted Cooling Coil
  INTEGER       :: CompOn                ! Determines if compressor is on or off

  ! Obtains and Allocates unitary system related parameters from input file
  IF (GetInputFlag) THEN
    ! Get the unitary system input
    CALL GetUnitarySystemInput
    GetInputFlag=.false.
  END IF

  ! Find the correct unitary system Number
  IF (CompIndex == 0) THEN
    UnitarySysNum = FindItemInList(UnitarySystemName,UnitarySystem%Name,NumUnitarySystem)
    IF (UnitarySysNum == 0) THEN
      CALL ShowFatalError('SimDXCoolingSystem: DXUnit not found='//TRIM(UnitarySystemName))
    END IF
    CompIndex=UnitarySysNum
  ELSE
    UnitarySysNum=CompIndex
    IF (UnitarySysNum > NumUnitarySystem .or. UnitarySysNum < 1) THEN
      CALL ShowFatalError('SimUnitarySystem:  Invalid CompIndex passed='//  &
                          TRIM(TrimSigDigits(UnitarySysNum))// &
                          ', Number of Unit Systems='//TRIM(TrimSigDigits(NumUnitarySystem))//  &
                          ', Unitary System name='//TRIM(UnitarySystemName))
    END IF
    IF (CheckEquipName(UnitarySysNum)) THEN
      IF (UnitarySystemName /= UnitarySystem(UnitarySysNum)%Name) THEN
        CALL ShowFatalError('SimUnitarySystem: Invalid CompIndex passed='//  &
                            TRIM(TrimSigDigits(UnitarySysNum))// &
                            ', Unitary System name='//TRIM(UnitarySystemName)//', stored Unit Name for that index='//  &
                            TRIM(UnitarySystem(UnitarySysNum)%Name))
      END IF
      CheckEquipName(UnitarySysNum)=.false.
    END IF
  END IF

  IF(PRESENT(HeatActive))HeatActive = .FALSE.
  IF(PRESENT(CoolActive))CoolActive = .FALSE.

  FanSpeedRatio = 1.0d0
  IF(PRESENT(ZoneEquipment))THEN
    CALL InitUnitarySystems(UnitarySysNum,0,OAUnitNUm,OAUCoilOutTemp, FirstHVACIteration)
  ELSE
    CALL InitUnitarySystems(UnitarySysNum,AirLoopNum,OAUnitNUm,OAUCoilOutTemp, FirstHVACIteration)
  END IF


  HXUnitOn = .FALSE.
  SELECT CASE(UnitarySystem(UnitarySysNum)%ControlType)
    CASE(SetPointBased)
      CompOn = 1
      IF(PRESENT(ZoneEquipment))THEN
        CALL ControlUnitarySystemtoSP(UnitarySysNum,FirstHVACIteration,0,OAUCoilOutTemp,HXUnitOn)
      ELSE
        CALL ControlUnitarySystemtoSP(UnitarySysNum,FirstHVACIteration,AirLoopNum,OAUCoilOutTemp,HXUnitOn)
      END IF
    CASE(LoadBased)
      IF(PRESENT(ZoneEquipment))THEN
        CALL ControlUnitarySystemtoLoad(UnitarySysNum,FirstHVACIteration,0,CompOn,OAUCoilOutTemp,HXUnitOn)
      ELSE
        CALL ControlUnitarySystemtoLoad(UnitarySysNum,FirstHVACIteration,AirLoopNum,CompOn,OAUCoilOutTemp,HXUnitOn)
      END IF
  END SELECT

  ! Report the current output
  IF(PRESENT(ZoneEquipment))THEN
    CALL ReportUnitarySystem(UnitarySysNum, 0)
  ELSE
    CALL ReportUnitarySystem(UnitarySysNum, AirLoopNum)
  END IF

  IF(PRESENT(CoolActive))THEN
    IF(UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac*REAL(CompOn,r64) > 0.0d0)CoolActive = .TRUE.
  END IF
  IF(PRESENT(HeatActive))THEN
    IF(UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac*REAL(CompOn,r64) > 0.0d0 .OR. &
     UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac*REAL(CompOn,r64) > 0.0d0)HeatActive = .TRUE.
  END IF

  ! set econo lockout flag
  ! If the sysem is not an equipment of Outdoor air unit
!  IF (AirLoopNum /=-1 .AND. ALLOCATED(AirLoopControlInfo) .AND. UnitarySystem(UnitarySysNum)%AirLoopEquipment) THEN
  IF (AirLoopNum > 0 .AND. ALLOCATED(AirLoopControlInfo) .AND. UnitarySystem(UnitarySysNum)%AirLoopEquipment) THEN

    IF ( (UnitarySystem(UnitarySysNum)%HeatCompPartLoadRatio > 0.0d0 .OR. &
          UnitarySystem(UnitarySysNum)%SpeedRatio > 0.0d0 .OR. &
          UnitarySystem(UnitarySysNum)%CycRatio > 0.0d0) .AND. &
          AirLoopControlInfo(AirLoopNum)%CanLockoutEconoWithCompressor) THEN
            AirLoopControlInfo(AirLoopNum)%ReqstEconoLockoutWithCompressor = .TRUE.
    ELSE
      AirLoopControlInfo(AirLoopNum)%ReqstEconoLockoutWithCompressor = .FALSE.
    END IF

    IF ((HeatActive) .AND. &
       (AirLoopControlInfo(AirLoopNum)%CanLockoutEconoWithCompressor .OR. &
        AirLoopControlInfo(AirLoopNum)%CanLockoutEconoWithHeating)) THEN
      AirLoopControlInfo(AirLoopNum)%ReqstEconoLockoutWithHeating = .TRUE.
    ELSE
      AirLoopControlInfo(AirLoopNum)%ReqstEconoLockoutWithHeating = .FALSE.
    END IF

  END IF

  ! Calculate heat recovery
  IF (UnitarySystem(UnitarySysNum)%HeatRecActive) THEN
    CALL UnitarySystemHeatRecovery(UnitarySysNum)
  END IF

  ! Coils should have been sized by now. Set this flag to false in case other equipment is downstream of Unitary System.
! can't do this since there are other checks that need this flag (e.g., HVACManager, line 3577)
!  AirLoopControlInfo(AirLoopNum)%UnitarySys = .FALSE.

  RETURN

END SUBROUTINE SimUnitarySystem

! Beginning of Initialization subroutines for the Module
! *****************************************************************************

SUBROUTINE InitUnitarySystems(UnitarySysNum,AirLoopNum,OAUnitNum,OAUCoilOutTemp,FirstHVACIteration)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine is for initializations of the unitary systems.

          ! METHODOLOGY EMPLOYED:
          ! Uses the status flags to trigger initializations.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DataAirLoop,     ONLY: AirLoopControlInfo
  USE DataAirflowNetwork, ONLY: AirflowNetworkUnitarySystem
  USE DataPlant,       ONLY: ScanPlantLoopsForObject, TypeOf_UnitarySystemRecovery, &
                             PlantLoop, TypeOf_CoilSteamAirHeating, TypeOf_CoilWaterSimpleHeating, &
                             TypeOf_CoilWaterCooling, TypeOf_CoilWaterDetailedFlatCooling
  USE FluidProperties, ONLY: GetDensityGlycol, GetSatDensityRefrig
  USE HeatingCoils,    ONLY: SimulateHeatingCoilComponents, GetHeatingCoilCapacity=>GetCoilCapacity
  USE WaterCoils,      ONLY: GetCoilMaxWaterFlowRate, SimulateWaterCoilComponents, SetCoilDesFlow
  USE HVACHXAssistedCoolingCoil,  ONLY: GetHXDXCoilName,GetHXDXCoilIndex, GetCoilObjectTypeNum
  USE SteamCoils,      ONLY: GetCoilMaxSteamFlowRate, SimulateSteamCoilComponents, &
                             GetSteamCoilCapacity=>GetCoilCapacity
  USE PlantUtilities,  ONLY: SetComponentFlowRate, InitComponentNodes

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT (IN)            :: UnitarySysNum       ! number of the current DX Sys being simulated
  INTEGER, INTENT (IN)            :: AirLoopNum          ! number of the current air loop being simulated
  INTEGER, INTENT (IN), OPTIONAL  :: OAUnitNum           ! number of the current Outdoor air unit being simulated
  REAL(r64), INTENT(IN), OPTIONAL :: OAUCoilOutTemp      ! the coil inlet temperature of OutdoorAirUnit
  LOGICAL, INTENT(IN)             :: FirstHVACIteration  ! True when first HVAC iteration

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  LOGICAL, ALLOCATABLE, SAVE, DIMENSION(:) :: MyEnvrnFlag              ! environment flag
  LOGICAL, ALLOCATABLE, SAVE, DIMENSION(:) :: MyPlantScanFlag          ! used for finding on heat recovery plant loop
  LOGICAL, ALLOCATABLE, SAVE, DIMENSION(:) :: MySuppCoilPlantScanFlag  ! used for finding on heat recovery plant loop
  LOGICAL, ALLOCATABLE, SAVE, DIMENSION(:) :: MySetPointCheckFlag      ! tests for set point
  LOGICAL, ALLOCATABLE, SAVE, DIMENSION(:) :: MySizingCheckFlag        ! tests for sizing
  LOGICAL,SAVE                             :: MyOneTimeFlag  = .TRUE.  ! one time flag
  CHARACTER(len=MaxNameLength) :: CoolingCoilType    =' '    ! Coil:Cooling:Water or Coil:Cooling:Water:DetailedGeometry
  CHARACTER(len=MaxNameLength) :: CoolingCoilName    =' '    ! Coil:Cooling:Water or Coil:Cooling:Water:DetailedGeometry
  CHARACTER(len=MaxNameLength) :: HeatingCoilType    =' '    ! Coil:Heating:Water or Coil:Heating:Steam
  LOGICAL             :: errFlag                 = .FALSE.   ! error flag for mining functions
  LOGICAL             :: ErrorsFound             = .FALSE.   ! error flag for mining functions
  INTEGER             :: ControlNode                         ! control node number
  INTEGER             :: OutdoorAirUnitNum                   ! "ONLY" for ZoneHVAC:OutdoorAirUnit
  INTEGER             :: SteamIndex              = 0         ! index of steam quality for steam heating coil
  INTEGER             :: TypeOfCoilWaterCooling  = 0         ! Used for simple water cool coil or detailed geometry
  INTEGER             :: TypeOfCoilWaterHeating  = 0         ! Used for simple water heat coil or steam coil
  REAL(r64)           :: OAUCoilOutletTemp       = 0.0d0     ! "ONLY" for zoneHVAC:OutdoorAirUnit [C]
  REAL(r64)           :: mdot                    = 0.0d0     ! local temporary for mass flow rate (kg/s)
  REAL(r64)           :: SteamDensity            = 0.0d0     ! density of steam at 100C, used for steam heating coils [kg/m3]
  REAL(r64)           :: CoilMaxVolFlowRate      = 0.0d0     ! coil fluid maximum volume flow rate [m3/s]
  REAL(r64)           :: QACTUAL                 = 0.0d0     ! coil actual capacity [W]
  REAL(r64)           :: rho                     = 0.0d0     ! local fluid density [kg/m3]
  REAL(r64)           :: mdotHR                  = 0.0d0     ! heat recovery mass flow rate [kg/s]
!  REAL(r64)           :: SaveMassFlow            = 0.0d0     ! saves node flow rate when checking heat coil capacity [m3/s]

IF (MyOneTimeFlag) THEN

  ALLOCATE(MyEnvrnFlag(NumUnitarySystem))
  ALLOCATE(MyPlantScanFlag(NumUnitarySystem))
  ALLOCATE(MySuppCoilPlantScanFlag(NumUnitarySystem))
  ALLOCATE(MySetPointCheckFlag(NumUnitarySystem))
  ALLOCATE(MySizingCheckFlag(NumUnitarySystem))

  MyEnvrnFlag = .TRUE.
  MyPlantScanFlag = .TRUE.
  MySuppCoilPlantScanFlag = .TRUE.
  MySetPointCheckFlag = .TRUE.
  MySizingCheckFlag = .TRUE.

  MyOneTimeFlag = .FALSE.
  AirflowNetworkUnitarySystem = .TRUE.
END IF

IF ( .NOT. SysSizingCalc .AND. MySizingCheckFlag(UnitarySysNum)) THEN
  IF(UnitarySystem(UnitarySysNum)%FanExists .AND. &
     (UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. &
      (UnitarySystem(UnitarySysNum)%HeatCoilExists .OR. UnitarySystem(UnitarySysNum)%SuppCoilExists))) &
        AirLoopControlInfo(AirLoopNum)%UnitarySys = .TRUE.
  AirLoopControlInfo(AirLoopNum)%UnitarySysSimulating = .TRUE.
  CALL SizeUnitarySystem(UnitarySysNum, FirstHVACIteration, AirLoopNum)
  MySizingCheckFlag(UnitarySysNum) = .FALSE.
  IF (AirLoopNum > 0) THEN
    AirLoopControlInfo(AirLoopNum)%FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode
    AirLoopControlInfo(AirLoopNum)%CycFanSchedPtr = UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr
  END IF
END IF

IF (AirLoopNum .EQ.-1) THEN ! This DX system is component of ZoneHVAC:OutdoorAirUnit
   OutdoorAirUnitNum=OAUnitNum
   OAUCoilOutletTemp=OAUCoilOutTemp
END IF

  ! Scan hot water and steam heating coil plant components for one time initializations
  IF (MyPlantScanFlag(UnitarySysNum) .AND. ALLOCATED(PlantLoop)) THEN
    IF (UnitarySystem(UnitarySysNum)%HeatRecActive) THEN
      errFlag=.FALSE.
      CALL ScanPlantLoopsForObject(UnitarySystem(UnitarySysNum)%Name, &
                                   TypeOf_UnitarySystemRecovery, &
                                   UnitarySystem(UnitarySysNum)%HRLoopNum, &
                                   UnitarySystem(UnitarySysNum)%HRLoopSideNum, &
                                   UnitarySystem(UnitarySysNum)%HRBranchNum, &
                                   UnitarySystem(UnitarySysNum)%HRCompNum, &
                                   errFlag=errFlag)
      IF (errFlag) THEN
        CALL ShowFatalError('InitUnitarySystems: Program terminated for previous conditions.')
      END IF
    END IF
    IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWater .OR. &
        UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterDetailed .OR. &
        UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilWater_CoolingHXAssisted) THEN
        IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWater) THEN
          TypeOfCoilWaterCooling = TypeOf_CoilWaterCooling
          CoolingCoilType = 'Coil:Cooling:Water'
          CoolingCoilName = UnitarySystem(UnitarySysNum)%CoolingCoilName
        ELSE IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterDetailed)THEN
          TypeOfCoilWaterCooling = TypeOf_CoilWaterDetailedFlatCooling
          CoolingCoilType = 'Coil:Cooling:Water:DetailedGeometry'
          CoolingCoilName = UnitarySystem(UnitarySysNum)%CoolingCoilName
        ELSE
          TypeOfCoilWaterCooling = GetCoilObjectTypeNum(cAllCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num), &
                                                        UnitarySystem(UnitarySysNum)%CoolingCoilName,ErrFlag,.TRUE.)
          IF(TypeOfCoilWaterCooling == Coil_CoolingWater)THEN
            TypeOfCoilWaterCooling = TypeOf_CoilWaterCooling
            CoolingCoilType = 'Coil:Cooling:Water'
          ELSE IF(TypeOfCoilWaterCooling == Coil_CoolingWaterDetailed)THEN
            TypeOfCoilWaterCooling = TypeOf_CoilWaterDetailedFlatCooling
            CoolingCoilType = 'Coil:Cooling:Water:DetailedGeometry'
          END IF
          CoolingCoilName = GetHXDXCoilName(cAllCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num), &
                                            UnitarySystem(UnitarySysNum)%CoolingCoilName,ErrFlag)
        END IF
        errFlag=.false.
        CALL ScanPlantLoopsForObject( TRIM(CoolingCoilName), &
                                      TypeOfCoilWaterCooling , &
                                      UnitarySystem(UnitarySysNum)%CoolCoilLoopNum, &
                                      UnitarySystem(UnitarySysNum)%CoolCoilLoopSide, &
                                      UnitarySystem(UnitarySysNum)%CoolCoilBranchNum, &
                                      UnitarySystem(UnitarySysNum)%CoolCoilCompNum,   &
                                      errFlag=errFlag)
        IF (errFlag) THEN
          CALL ShowFatalError('InitUnitarySystem: Program terminated for previous conditions.')
        END IF
        UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow = GetCoilMaxWaterFlowRate(CoolingCoilType,  &
                                                   CoolingCoilName,ErrorsFound)

        IF(UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow .GT. 0.0d0)THEN
            rho = GetDensityGlycol(PlantLoop(UnitarySystem(UnitarySysNum)%CoolCoilLoopNum)%FluidName, &
                                   InitConvTemp, &
                                   PlantLoop(UnitarySystem(UnitarySysNum)%CoolCoilLoopNum)%FluidIndex, &
                                   'InitUnitarySystem')
            UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow = UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow * rho
        END IF
        ! fill outlet node for coil
        UnitarySystem(UnitarySysNum)%CoolCoilFluidOutletNodeNum =  &
            PlantLoop(UnitarySystem(UnitarySysNum)%CoolCoilLoopNum)%LoopSide(UnitarySystem(UnitarySysNum)%CoolCoilLoopSide) &
            %Branch(UnitarySystem(UnitarySysNum)%CoolCoilBranchNum)%Comp(UnitarySystem(UnitarySysNum)%CoolCoilCompNum)%NodeNumOut

    END IF
    IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWater .OR. &
        UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingSteam) THEN
        IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWater) THEN
          TypeOfCoilWaterHeating = TypeOf_CoilWaterSimpleHeating
          HeatingCoilType = 'Coil:Heating:Water'
          CALL SetCoilDesFlow(CALLCoilTypes(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num), &
                              UnitarySystem(UnitarySysNum)%HeatingCoilName, &
                              UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow,&
                              ErrorsFound)
        ELSE
          TypeOfCoilWaterHeating = TypeOf_CoilSteamAirHeating
          HeatingCoilType = 'Coil:Heating:Steam'
        END IF
        errFlag=.false.
        CALL ScanPlantLoopsForObject( UnitarySystem(UnitarySysNum)%HeatingCoilName, &
                                      TypeOfCoilWaterHeating , &
                                      UnitarySystem(UnitarySysNum)%HeatCoilLoopNum, &
                                      UnitarySystem(UnitarySysNum)%HeatCoilLoopSide, &
                                      UnitarySystem(UnitarySysNum)%HeatCoilBranchNum, &
                                      UnitarySystem(UnitarySysNum)%HeatCoilCompNum,   &
                                      errFlag=errFlag)
        IF (errFlag) THEN
          CALL ShowFatalError('InitUnitarySystem: Program terminated for previous conditions.')
        END IF
        IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWater) THEN
          UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow = GetCoilMaxWaterFlowRate(HeatingCoilType,  &
                                                     UnitarySystem(UnitarySysNum)%HeatingCoilName,ErrorsFound)

          IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow .GT. 0.0d0)THEN
              rho = GetDensityGlycol(PlantLoop(UnitarySystem(UnitarySysNum)%HeatCoilLoopNum)%FluidName, &
                                     InitConvTemp, &
                                     PlantLoop(UnitarySystem(UnitarySysNum)%HeatCoilLoopNum)%FluidIndex, &
                                     'InitUnitarySystem')
              UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow = GetCoilMaxWaterFlowRate(HeatingCoilType,  &
                                      UnitarySystem(UnitarySysNum)%HeatingCoilName,ErrorsFound) * rho
          END IF
        ELSE
          UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow =   &
             GetCoilMaxSteamFlowRate(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrorsFound)
          IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow .GT. 0.0d0)THEN
            SteamIndex = 0 ! Function GetSatDensityRefrig will look up steam index if 0 is passed
            SteamDensity=GetSatDensityRefrig('STEAM',TempSteamIn,1.0d0,SteamIndex,'InitUnitarySystem')
            UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow = UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow * SteamDensity
          END IF
        END IF
        ! fill outlet node for coil
        UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum =  &
            PlantLoop(UnitarySystem(UnitarySysNum)%HeatCoilLoopNum)%LoopSide(UnitarySystem(UnitarySysNum)%HeatCoilLoopSide) &
            %Branch(UnitarySystem(UnitarySysNum)%HeatCoilBranchNum)%Comp(UnitarySystem(UnitarySysNum)%HeatCoilCompNum)%NodeNumOut
    END IF

    MyPlantScanFlag(UnitarySysNum) = .FALSE.

  ELSEIF (MyPlantScanFlag(UnitarySysNum) .AND. .NOT. AnyPlantInModel) THEN
    MyPlantScanFlag(UnitarySysNum) = .FALSE.
  END IF

  ! Scan Supplemental hot water and steam heating coil plant components for one time initializations
  IF (MySuppCoilPlantScanFlag(UnitarySysNum) .AND. ALLOCATED(PlantLoop)) THEN
    IF (UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingWater) THEN
        errFlag=.false.
        CALL ScanPlantLoopsForObject( UnitarySystem(UnitarySysNum)%SuppHeatCoilName, &
                                      TypeOf_CoilWaterSimpleHeating , &
                                      UnitarySystem(UnitarySysNum)%SuppCoilLoopNum, &
                                      UnitarySystem(UnitarySysNum)%SuppCoilLoopSide, &
                                      UnitarySystem(UnitarySysNum)%SuppCoilBranchNum, &
                                      UnitarySystem(UnitarySysNum)%SuppCoilCompNum,   &
                                      errFlag=errFlag)
        CALL SetCoilDesFlow(CALLCoilTypes(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num), &
                            UnitarySystem(UnitarySysNum)%SuppHeatCoilName, &
                            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow,&
                            ErrorsFound)

        IF (errFlag) THEN
          CALL ShowFatalError('InitUnitarySystems: Program terminated for previous conditions.')
        END IF
        UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                                   UnitarySystem(UnitarySysNum)%SuppHeatCoilName,ErrorsFound)

        IF(UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow .GT. 0.0d0)THEN
            rho = GetDensityGlycol(PlantLoop(UnitarySystem(UnitarySysNum)%SuppCoilLoopNum)%FluidName, &
                                   InitConvTemp, &
                                   PlantLoop(UnitarySystem(UnitarySysNum)%SuppCoilLoopNum)%FluidIndex, &
                                   'InitUnitarySystems')
            UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                    UnitarySystem(UnitarySysNum)%SuppHeatCoilName,ErrorsFound) * rho
        END IF
        ! fill outlet node for coil
        UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum =  &
            PlantLoop(UnitarySystem(UnitarySysNum)%SuppCoilLoopNum)%LoopSide(UnitarySystem(UnitarySysNum)%SuppCoilLoopSide) &
            %Branch(UnitarySystem(UnitarySysNum)%SuppCoilBranchNum)%Comp(UnitarySystem(UnitarySysNum)%SuppCoilCompNum)%NodeNumOut

    ELSEIF (UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingSteam) THEN
        errFlag=.false.
        CALL ScanPlantLoopsForObject(UnitarySystem(UnitarySysNum)%SuppHeatCoilName, &
                                     TypeOf_CoilSteamAirHeating , &
                                     UnitarySystem(UnitarySysNum)%SuppCoilLoopNum, &
                                     UnitarySystem(UnitarySysNum)%SuppCoilLoopSide, &
                                     UnitarySystem(UnitarySysNum)%SuppCoilBranchNum, &
                                     UnitarySystem(UnitarySysNum)%SuppCoilCompNum,   &
                                     errFlag=errFlag)
        IF (errFlag) THEN
          CALL ShowFatalError('InitUnitarySystems: Program terminated for previous conditions.')
        END IF
        UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow =   &
           GetCoilMaxSteamFlowRate(UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,ErrorsFound)
        IF(UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow .GT. 0.0d0)THEN
          SteamIndex = 0 ! Function GetSatDensityRefrig will look up steam index if 0 is passed
          SteamDensity=GetSatDensityRefrig('STEAM',TempSteamIn,1.0d0,SteamIndex,'InitUnitarySystems')
          UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow = UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow * SteamDensity
        END IF

      ! fill outlet node for coil
      UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum =  &
            PlantLoop(UnitarySystem(UnitarySysNum)%SuppCoilLoopNum)%LoopSide(UnitarySystem(UnitarySysNum)%SuppCoilLoopSide) &
            %Branch(UnitarySystem(UnitarySysNum)%SuppCoilBranchNum)%Comp(UnitarySystem(UnitarySysNum)%SuppCoilCompNum)%NodeNumOut
    END IF

    MySuppCoilPlantScanFlag(UnitarySysNum) = .FALSE.

  ELSEIF (MySuppCoilPlantScanFlag(UnitarySysNum) .AND. .NOT. AnyPlantInModel) THEN
    MySuppCoilPlantScanFlag(UnitarySysNum) = .FALSE.
  END IF

! do the Begin Environment initializations
  IF (BeginEnvrnFlag .and. MyEnvrnFlag(UnitarySysNum)) THEN
    UnitarySystem(UnitarySysNum)%DesignMassFlowRate = UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate * StdRhoAir
    UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow * StdRhoAir
    UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow *  StdRhoAir
    UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirMassFlow = UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow * StdRhoAir
    UnitarySystem(UnitarySysNum)%SenLoadLoss = 0.0d0
    IF (UnitarySystem(UnitarySysNum)%Humidistat) THEN
      UnitarySystem(UnitarySysNum)%LatLoadLoss = 0.0d0
    END IF

    IF ((UnitarySystem(UnitarySysNum)%HeatRecActive) .AND. (.NOT. MyPlantScanFlag(UnitarySysNum)) ) THEN

      rho = GetDensityGlycol(PlantLoop(UnitarySystem(UnitarySysNum)%HRLoopNum)%FluidName, &
                             60.0d0, &
                             PlantLoop(UnitarySystem(UnitarySysNum)%HRLoopNum)%FluidIndex, &
                             'InitUnitarySystems')

      UnitarySystem(UnitarySysNum)%DesignHeatRecMassFlowRate = UnitarySystem(UnitarySysNum)%DesignHRWaterVolumeFlow * rho

      CALL InitComponentNodes(0.0d0, UnitarySystem(UnitarySysNum)%DesignHeatRecMassFlowRate, &
                              UnitarySystem(UnitarySysNum)%HeatRecoveryInletNodeNum, &
                              UnitarySystem(UnitarySysNum)%HeatRecoveryOutletNodeNum, &
                              UnitarySystem(UnitarySysNum)%HRLoopNum, &
                              UnitarySystem(UnitarySysNum)%HRLoopSideNum, &
                              UnitarySystem(UnitarySysNum)%HRBranchNum, &
                              UnitarySystem(UnitarySysNum)%HRCompNum )
    END IF
!   set fluid-side hardware limits
    IF(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode .GT. 0)THEN

      IF(UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow .EQ. Autosize)THEN
          ! If water coil max water flow rate is autosized, simulate once in order to mine max flow rate
        IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWater) THEN
            CoolingCoilType = 'Coil:Cooling:Water'
        ELSE
            CoolingCoilType = 'Coil:Cooling:Water:DetailedGeometry'
        END IF
        CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%CoolingCoilName,FirstHVACIteration, &
                                         UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
        CoilMaxVolFlowRate = GetCoilMaxWaterFlowRate(CoolingCoilType, UnitarySystem(UnitarySysNum)%CoolingCoilName, &
                                                     ErrorsFound)
        IF(CoilMaxVolFlowRate .NE. Autosize) THEN
          rho = GetDensityGlycol(PlantLoop(UnitarySystem(UnitarySysNum)%CoolCoilLoopNum)%fluidName, &
                                 InitConvTemp, &
                                 PlantLoop(UnitarySystem(UnitarySysNum)%CoolCoilLoopNum)%fluidIndex, &
                                 'InitUnitarySystem')
          UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow = CoilMaxVolFlowRate * rho
        END IF
      END IF

      CALL InitComponentNodes(0.0d0, UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow, &
                                    UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode, &
                                    UnitarySystem(UnitarySysNum)%CoolCoilFluidOutletNodeNum, &
                                    UnitarySystem(UnitarySysNum)%CoolCoilLoopNum, &
                                    UnitarySystem(UnitarySysNum)%CoolCoilLoopSide, &
                                    UnitarySystem(UnitarySysNum)%CoolCoilBranchNum, &
                                    UnitarySystem(UnitarySysNum)%CoolCoilCompNum )
    END IF
    IF(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode .GT. 0)THEN

        IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow .EQ. Autosize)THEN
            ! IF water coil max water flow rate is autosized, simulate once in order to mine max flow rate
            IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWater) THEN
                CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%HeatingCoilName,FirstHVACIteration, &
                                                UnitarySystem(UnitarySysNum)%HeatingCoilIndex)
                CoilMaxVolFlowRate = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                                             UnitarySystem(UnitarySysNum)%HeatingCoilName,ErrorsFound)
                IF(CoilMaxVolFlowRate .NE. Autosize) THEN
                    rho = GetDensityGlycol(PlantLoop(UnitarySystem(UnitarySysNum)%HeatCoilLoopNum)%fluidName, &
                                            InitConvTemp, &
                                            PlantLoop(UnitarySystem(UnitarySysNum)%HeatCoilLoopNum)%fluidIndex, &
                                            'InitUnitarySystems')
                    UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow = CoilMaxVolFlowRate * rho
                END IF
            END IF
            ! If steam coil max steam flow rate is autosized, simulate once in order to mine max flow rate
            IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingSteam) THEN
                CALL SimulateSteamCoilComponents(UnitarySystem(UnitarySysNum)%HeatingCoilName, &
                                                FirstHVACIteration,    &
                                                1.0d0, & !QCoilReq, simulate any load > 0 to get max capacity
                                                UnitarySystem(UnitarySysNum)%HeatingCoilIndex, QActual)
                CoilMaxVolFlowRate = GetCoilMaxSteamFlowRate(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrorsFound)
                IF(CoilMaxVolFlowRate .NE. Autosize) THEN
                   SteamIndex = 0 ! Function GetSatDensityRefrig will look up steam index if 0 is passed
                   SteamDensity=GetSatDensityRefrig('STEAM',TempSteamIn,1.0d0,SteamIndex,'InitUnitarySystems')
                   UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow = CoilMaxVolFlowRate * SteamDensity
                END IF
            END IF
        END IF

        CALL InitComponentNodes(0.0d0, UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilLoopNum, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilLoopSide, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilBranchNum, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilCompNum )
    END IF
    IF(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode .GT. 0)THEN
        IF(UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow .EQ. Autosize)THEN
            IF(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingWater) THEN
                ! If water coil max water flow rate is autosized, simulate once in order to mine max flow rate
                CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%SuppHeatCoilName,FirstHVACIteration, &
                                                UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex)
                CoilMaxVolFlowRate = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                                            UnitarySystem(UnitarySysNum)%SuppHeatCoilName,ErrorsFound)
                IF(CoilMaxVolFlowRate .NE. Autosize) THEN
                    rho = GetDensityGlycol(PlantLoop(UnitarySystem(UnitarySysNum)%SuppCoilLoopNum)%fluidName, &
                                        InitConvTemp, &
                                        PlantLoop(UnitarySystem(UnitarySysNum)%SuppCoilLoopNum)%fluidIndex, &
                                        'InitUnitarySystems')
                    UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow = CoilMaxVolFlowRate * rho
                END IF
            END IF
            IF(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingSteam) THEN
                CALL SimulateSteamCoilComponents(UnitarySystem(UnitarySysNum)%SuppHeatCoilName, &
                                                FirstHVACIteration,    &
                                                1.0d0, & !QCoilReq, simulate any load > 0 to get max capacity
                                                UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, QActual)
                CoilMaxVolFlowRate = GetCoilMaxSteamFlowRate(UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,ErrorsFound)
                IF(CoilMaxVolFlowRate .NE. Autosize) THEN
                  SteamIndex = 0 ! Function GetSatDensityRefrig will look up steam index if 0 is passed
                  SteamDensity=GetSatDensityRefrig('STEAM',TempSteamIn,1.0d0,SteamIndex,'InitUnitarySystems')
                  UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow = CoilMaxVolFlowRate * SteamDensity
                END IF
            END IF
            CALL InitComponentNodes(0.0d0, UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilLoopNum, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilLoopSide, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilBranchNum, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilCompNum )
        END IF
    END IF
    IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingGas .OR. &
       UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingElectric)THEN
      CALL SimulateHeatingCoilComponents(UnitarySystem(UnitarySysNum)%HeatingCoilName,FirstHVACIteration, &
                                CompIndex=UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                QCoilReq=1.0d0, &
                                FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                PartLoadRatio=1.0d0)
      UnitarySystem(UnitarySysNum)%DesignHeatingCapacity =   &
             GetHeatingCoilCapacity(CALLCoilTypes(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num), &
                                    UnitarySystem(UnitarySysNum)%HeatingCoilName,ErrFlag)
    END IF
    MyEnvrnFlag(UnitarySysNum) = .FALSE.
  END IF

  IF (.not. BeginEnvrnFlag) THEN
    MyEnvrnFlag(UnitarySysNum) = .TRUE.
  END IF

  !Init maximum available Heat Recovery flow rate
  IF ((UnitarySystem(UnitarySysNum)%HeatRecActive) .AND. (.NOT. MyPlantScanFlag(UnitarySysNum)) ) THEN
    IF (GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%SysAvailSchedPtr) .GT. 0.0d0) THEN
      IF (FirstHVACIteration) THEN
        mdotHR = UnitarySystem(UnitarySysNum)%DesignHeatRecMassFlowRate
      ELSE
        IF (UnitarySystem(UnitarySysNum)%HeatRecoveryMassFlowRate > 0.0d0) THEN
          mdotHR = UnitarySystem(UnitarySysNum)%HeatRecoveryMassFlowRate
        ELSE
          mdotHR = UnitarySystem(UnitarySysNum)%DesignHeatRecMassFlowRate
        END IF
      END IF
    ELSE
      mdotHR = 0.0d0
    END IF

    mdotHR = MIN(Node(UnitarySystem(UnitarySysNum)%HeatRecoveryOutletNodeNum)%MassFlowRateMaxAvail,mdotHR)
    Node(UnitarySystem(UnitarySysNum)%HeatRecoveryInletNodeNum)%MassFlowRate = mdotHR
  END IF

  ! get operating capacity of water and steam coil
  IF(FirstHVACIteration .OR. UnitarySystem(UnitarySysNum)%DehumidControlType_Num == DehumidControl_CoolReheat) THEN
    IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWater .OR. &
       UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterDetailed) THEN
      !     set air-side and steam-side mass flow rates
      mdot = MIN(Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
             UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow)
      Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode)%MassFlowRate = mdot
      !     simulate water coil to find operating capacity
      CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%CoolingCoilName,FirstHVACIteration, &
                                                UnitarySystem(UnitarySysNum)%CoolingCoilIndex, QActual)
      UnitarySystem(UnitarySysNum)%DesignCoolingCapacity = QActual
    END IF ! from IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWater .OR. Coil_CoolingWaterDetailed
    IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWater) THEN
      !     set air-side and steam-side mass flow rates
      mdot = MIN(Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
             UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow)
      Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode)%MassFlowRate = mdot
      !     simulate water coil to find operating capacity
!      SaveMassFlow = Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%MassFlowRate
!      Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%MassFlowRate = UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow
      CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%HeatingCoilName,FirstHVACIteration, &
                                                UnitarySystem(UnitarySysNum)%HeatingCoilIndex, QActual)
      UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = QActual
!      Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%MassFlowRate = SaveMassFlow
    END IF ! from IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWater) THEN

    IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingSteam) THEN

      !     set air-side and steam-side mass flow rates
      mdot = MIN(Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
             UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow)
      Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode)%MassFlowRate = mdot

!     simulate steam coil to find operating capacity
      CALL SimulateSteamCoilComponents(UnitarySystem(UnitarySysNum)%HeatingCoilName, &
                                       FirstHVACIteration,    &
                                       1.0d0, & !QCoilReq, simulate any load > 0 to get max capacity of steam coil
                                       UnitarySystem(UnitarySysNum)%HeatingCoilIndex, QActual)

      UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = &
             GetSteamCoilCapacity(CALLCoilTypes(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num), &
                                                UnitarySystem(UnitarySysNum)%HeatingCoilName,ErrorsFound)
    END IF ! from IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingSteam) THEN
    IF(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingWater) THEN
      !     set air-side and steam-side mass flow rates
      mdot = MIN(Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
             UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow)
      Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode)%MassFlowRate = mdot
!      SaveMassFlow = Node(UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode)%MassFlowRate
!      Node(UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode)%MassFlowRate = UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow
      !     simulate water coil to find operating capacity
      IF(mdot > 0.0d0)THEN
!        Node(UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode)%MassFlowRate = &
!          UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow
        CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%SuppHeatCoilName,FirstHVACIteration, &
                                                UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, QActual)
        UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity = QActual
      ELSE
        UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity = 0.0d0
      END IF
!      Node(UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode)%MassFlowRate = SaveMassFlow

    END IF ! from IF(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingWater) THEN

    IF(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingSteam) THEN

      !     set air-side and steam-side mass flow rates
      mdot = MIN(Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
             UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow)
      Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode)%MassFlowRate = mdot

!     simulate steam coil to find operating capacity
      CALL SimulateSteamCoilComponents(UnitarySystem(UnitarySysNum)%SuppHeatCoilName, &
                                       FirstHVACIteration,    &
                                       1.0d0, & !QCoilReq, simulate any load > 0 to get max capacity of steam coil
                                       UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, QActual)
      UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity = GetSteamCoilCapacity('Coil:Heating:Steam', &
                                                      UnitarySystem(UnitarySysNum)%SuppHeatCoilName,ErrorsFound)

    END IF ! from IF(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingSteam) THEN
END IF ! from IF( FirstHVACIteration ) THEN

IF(MySetPointCheckFlag(UnitarySysNum))THEN
  IF ( .NOT. SysSizingCalc .AND. DOSetPointTest) THEN

    IF(UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
      ControlNode = UnitarySystem(UnitarySysNum)%SystemCoolControlNodeNum
      IF (ControlNode > 0) THEN
        CALL CheckNodeSetPoint(UnitarySysNum,AirLoopNum, ControlNode, CoolingCoil,OAUCoilOutTemp)
      END IF
    END IF

    IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
      ControlNode = UnitarySystem(UnitarySysNum)%SystemHeatControlNodeNum
      IF (ControlNode > 0) THEN
        CALL CheckNodeSetPoint(UnitarySysNum,AirLoopNum, ControlNode,HeatingCoil,OAUCoilOutTemp)
      END IF
    END IF

    IF(UnitarySystem(UnitarySysNum)%SuppCoilExists)THEN
      ControlNode = UnitarySystem(UnitarySysNum)%SuppHeatControlNodeNum
      IF (ControlNode > 0) THEN
        CALL CheckNodeSetPoint(UnitarySysNum,AirLoopNum, ControlNode,SuppHeatCoil,OAUCoilOutTemp)
      END IF
    END IF

    MySetPointCheckFlag(UnitarySysNum) = .FALSE.
  END IF
END IF

UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac  = 0.0d0
UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac  = 0.0d0
UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac = 0.0d0
UnitarySystem(UnitarySysNum)%CoolingCycRatio      = 0.0d0
UnitarySystem(UnitarySysNum)%CoolingSpeedRatio    = 0.0d0
UnitarySystem(UnitarySysNum)%CoolingSpeedNum      = 0.0d0
UnitarySystem(UnitarySysNum)%HeatingCycRatio      = 0.0d0
UnitarySystem(UnitarySysNum)%HeatingSpeedRatio    = 0.0d0
UnitarySystem(UnitarySysNum)%HeatingSpeedNum      = 0.0d0
UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand   = 0.0d0
UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand   = 0.0d0
UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand = 0.0d0
UnitarySystem(UnitarySysNum)%DehumidInducedHeatingDemandRate = 0.0d0

UnitarySystem(UnitarySysNum)%InitHeatPump = .TRUE.

RETURN
END SUBROUTINE InitUnitarySystems

SUBROUTINE CheckNodeSetPoint(UnitarySysNum,AirLoopNum, ControlNode, CoilType,OAUCoilOutTemp)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   March 2013
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine checks for proper set point at control node.

          ! METHODOLOGY EMPLOYED:
          ! Uses the control node to test for set point.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE EMSManager,      ONLY: iTemperatureSetpoint, CheckIfNodeSetpointManagedByEMS, iHumidityRatioMaxSetpoint

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT (IN) :: UnitarySysNum               ! number of the current DX Sys being simulated
  INTEGER, INTENT (IN) :: AirLoopNum                  ! number of the current air loop being simulated
  INTEGER, INTENT (IN) :: ControlNode                 ! Node to test for set point
  INTEGER, INTENT (IN) :: CoilType                    ! True if cooling coil, then test for HumRatMax set point
  REAL(r64), INTENT(IN), OPTIONAL :: OAUCoilOutTemp   ! the coil inlet temperature of OutdoorAirUnit

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
          ! na

IF (AirLoopNum .EQ.-1) THEN                           ! Outdoor Air Unit
  Node(ControlNode)%TempSetPoint = OAUCoilOutTemp     ! Set the coil outlet temperature
  IF(UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil) THEN
    CALL FrostControlSetPointLimit(UnitarySysNum,UnitarySystem(UnitarySysNum)%DesiredOutletTemp,Node(ControlNode)%HumRatMax, &
                                   OutBaroPress, UnitarySystem(UnitarySysNum)%DOASDXCoolingCoilMinTout,1)
  END IF
ELSEIF (AirLoopNum /= -1) THEN ! Not an Outdoor air unit

  IF (Node(ControlNode)%TempSetPoint == SensedNodeFlagValue .AND. &
      UnitarySystem(UnitarySysNum)%ControlType == SetPointBased) THEN
    IF (.NOT. AnyEnergyManagementSystemInModel) THEN
      CALL ShowSevereError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//&
                       ': Missing temperature setpoint for unitary system = ' //TRIM(UnitarySystem(UnitarySysNum)%Name))
      CALL ShowContinueError('  use a Setpoint Manager to establish a setpoint at the coil control node.')
      SetPointErrorFlag = .TRUE.
    ELSE
      CALL CheckIfNodeSetpointManagedByEMS(ControlNode,iTemperatureSetpoint, SetpointErrorFlag)
      IF (SetpointErrorFlag) THEN
        CALL ShowSevereError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//&
                       ': Missing temperature setpoint for unitary system = ' //TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('  use a Setpoint Manager to establish a setpoint at the coil control node.')
        CALL ShowContinueError('  or use an EMS actuator to establish a temperature setpoint at the coil control node.')
      END IF
    END IF
  END IF
  IF ((UnitarySystem(UnitarySysNum)%DehumidControlType_Num .NE. DehumidControl_None) .AND. &
      (Node(ControlNode)%HumRatMax == SensedNodeFlagValue) .AND. &
      UnitarySystem(UnitarySysNum)%ControlType == SetPointBased .AND. CoilType .EQ. CoolingCoil) THEN
    IF (.NOT. AnyEnergyManagementSystemInModel) THEN
      CALL ShowSevereError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//&
                       ': Missing humidity ratio setpoint (HUMRATMAX) for unitary system = ' &
                                  //TRIM(UnitarySystem(UnitarySysNum)%Name))
      CALL ShowContinueError('  use a Setpoint Manager to establish a setpoint at the coil control node.')
      SetPointErrorFlag = .TRUE.
    ELSE
      CALL CheckIfNodeSetpointManagedByEMS(ControlNode,iHumidityRatioMaxSetpoint, SetpointErrorFlag)
      IF (SetpointErrorFlag) THEN
        CALL ShowSevereError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//&
                       ': Missing maximum humidity ratio setpoint (HUMRATMAX) for unitary system = ' &
                                 //TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('  use a Setpoint Manager to establish a setpoint at the coil control node.')
        CALL ShowContinueError('  or use an EMS actuator to establish a maximum humidity ratio setpoint.')
      END IF
    END IF

  END IF
END IF


RETURN
END SUBROUTINE CheckNodeSetPoint

SUBROUTINE UpdateUnitarySystemControl(UnitarySysNum,AirLoopNum,OutNode,ControlNode,OnOffAirFlowRatio, &
                                    OAUCoilOutletTemp,FirstHVACIteration, ZoneLoad,MaxOutletTemp)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine is for sizing unitary systems.

          ! METHODOLOGY EMPLOYED:
          ! Either CALL the coil model to get the size or size coil.
          ! Current method is to use same methodology as is used in coil objects.
          ! Future changes will include a common sizing algorithm and push the calculated
          ! size to the coil object prior to first call (so the coil will not autosize).

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DataAirLoop,           ONLY: AirLoopControlInfo
  USE Psychrometrics,        ONLY: PsyHfgAirFnWTdb
  USE DataHeatBalFanSys,     ONLY: TempControlType
  USE DataZoneEnergyDemands

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT (IN)   :: UnitarySysNum                ! number of the current DX Sys being simulated
  INTEGER, INTENT (IN)   :: AirLoopNum                   ! number of the current air loop being simulated
  INTEGER, INTENT (IN)   :: OutNode                      ! coil outlet node number
  INTEGER, INTENT (IN)   :: ControlNode                  ! control node number
  LOGICAL, INTENT (IN)   :: FirstHVACIteration
  REAL(r64), INTENT (IN) :: OAUCoilOutletTemp            ! "ONLY" for zoneHVAC:OutdoorAirUnit
  REAL(R64), INTENT (INOUT)           :: OnOffAirFlowRatio
  REAL(R64), INTENT (INOUT), OPTIONAL :: ZoneLoad
  REAL(R64), INTENT (IN), OPTIONAL    :: MaxOutletTemp   ! limits heating coil outlet temp [C]

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER   :: ControlType
REAL(r64) :: H2OHtOfVap                  ! Heat of vaporization of air

ControlType = UnitarySystem(UnitarySysNum)%ControlType
! These initializations are done every iteration

SELECT CASE(ControlType)
  CASE(LoadBased)
    IF (AirLoopNum .EQ.-1) THEN ! This IF-THEN routine is just for ZoneHVAC:OutdoorAirUnit
      CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                            ' "'//TRIM(UnitarySystem(UnitarySysNum)%Name)//'"')
      CALL ShowFatalError('...Load based control is not allowed when used with ZoneHVAC:OutdoorAirUnit')
    END IF

  ! here we need to deal with sequenced zone equip
    HeatingLoad = .FALSE.
    CoolingLoad = .FALSE.
    IF (UnitarySystem(UnitarySysNum)%ZoneSequenceCoolingNum > 0 .AND. UnitarySystem(UnitarySysNum)%ZoneSequenceHeatingNum > 0)THEN
      QToCoolSetPt = ZoneSysEnergyDemand(UnitarySystem(UnitarySysNum)%ControlZoneNum)%&
                  SequencedOutputRequiredToCoolingSP(UnitarySystem(UnitarySysNum)%ZoneSequenceCoolingNum)
      QToHeatSetPt = ZoneSysEnergyDemand(UnitarySystem(UnitarySysNum)%ControlZoneNum)%&
                  SequencedOutputRequiredToHeatingSP(UnitarySystem(UnitarySysNum)%ZoneSequenceHeatingNum)
      IF (QToHeatSetPt > 0.0d0 .AND. QToCoolSetPt > 0.0d0 .AND. &
          TempControlType(UnitarySystem(UnitarySysNum)%ControlZoneNum) .NE. SingleCoolingSetPoint) THEN
        ZoneLoad = QToHeatSetPt
        HeatingLoad = .TRUE.
      ELSEIF (QToHeatSetPt > 0.0d0 .AND. QToCoolSetPt > 0.0d0 .AND. &
          TempControlType(UnitarySystem(UnitarySysNum)%ControlZoneNum) .EQ. SingleCoolingSetPoint) THEN
        ZoneLoad = 0.0d0
      ELSEIF (QToHeatSetPt < 0.0d0 .AND. QToCoolSetPt < 0.0d0 .AND. &
          TempControlType(UnitarySystem(UnitarySysNum)%ControlZoneNum) .NE. SingleHeatingSetPoint) THEN
        ZoneLoad = QToCoolSetPt
        CoolingLoad = .TRUE.
      ELSEIF (QToHeatSetPt < 0.0d0 .AND. QToCoolSetPt < 0.0d0 .AND. &
          TempControlType(UnitarySystem(UnitarySysNum)%ControlZoneNum) .EQ. SingleHeatingSetPoint) THEN
        ZoneLoad = 0.0d0
      ELSEIF (QToHeatSetPt <= 0.0d0 .AND. QToCoolSetPt >= 0.0d0) THEN
        ZoneLoad = 0.0d0
      END IF
      MoistureLoad = ZoneSysMoistureDemand(UnitarySystem(UnitarySysNum)%ControlZoneNum)% &
                     SequencedOutputRequiredToDehumidSP(UnitarySystem(UnitarySysNum)%ZoneSequenceCoolingNum)
    ELSE
      ZoneLoad= ZoneSysEnergyDemand(UnitarySystem(UnitarySysNum)%ControlZoneNum)%RemainingOutputRequired
      QToCoolSetPt=ZoneSysEnergyDemand(UnitarySystem(UnitarySysNum)%ControlZoneNum)%OutputRequiredToCoolingSP
      QToHeatSetPt=ZoneSysEnergyDemand(UnitarySystem(UnitarySysNum)%ControlZoneNum)%OutputRequiredToHeatingSP
      MoistureLoad = ZoneSysMoistureDemand(UnitarySystem(UnitarySysNum)%ControlZoneNum)%OutputRequiredToDehumidIFyingSP
    END IF

    IF ( UnitarySystem(UnitarySysNum)%DehumidControlType_Num .NE. DehumidControl_None)THEN
      H2OHtOfVap = PsyHfgAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%HumRat,&
                        Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%Temp,'UpdateUnitarySystemControl')

      ! positive MoistureLoad means no dehumidification load
      MoistureLoad = MIN(0.0d0,MoistureLoad * H2OHtOfVap)
    ELSE
      MoistureLoad = 0.0d0
    END IF

    CALL InitLoadBasedControl(UnitarySysNum,AirLoopNum,FirstHVACIteration,OnOffAirFlowRatio,ZoneLoad)

    ! EMS override point
    IF (UnitarySystem(UnitarySysNum)%EMSOverrideSensZoneLoadRequest) &
      ZoneLoad = UnitarySystem(UnitarySysNum)%EMSSensibleZoneLoadValue
    IF (UnitarySystem(UnitarySysNum)%EMSOverrideMoistZoneLoadRequest) &
      MoistureLoad = UnitarySystem(UnitarySysNum)%EMSMoistureZoneLoadValue

  CASE(SetPointBased)
    IF (AirLoopNum .EQ.-1) THEN ! This IF-THEN routine is just for ZoneHVAC:OutdoorAIRUNIT

      IF (ControlNode.EQ.0) THEN
        UnitarySystem(UnitarySysNum)%DesiredOutletTemp = OAUCoilOutletTemp
        UnitarySystem(UnitarySysNum)%DesiredOutletHumRat = 1.0d0
      ELSEIF (ControlNode.EQ.OutNode) THEN
        UnitarySystem(UnitarySysNum)%DesiredOutletTemp =OAUCoilOutletTemp
      END IF
      ! If the unitary system is an equipment of Outdoor Air Unit, the desired coil outlet humidity level is set to zero
      UnitarySystem(UnitarySysNum)%DesiredOutletHumRat = 1.0d0

    ELSE ! Not Outdoor Air Unit or zone equipment
      IF(AirLoopNum .GT. 0)EconomizerFlag = AirLoopControlInfo(AirLoopNum)%EconoActive
      IF (ControlNode.EQ.0) THEN
        UnitarySystem(UnitarySysNum)%DesiredOutletTemp = 0.0d0
        UnitarySystem(UnitarySysNum)%DesiredOutletHumRat = 1.0d0
      ELSEIF (ControlNode.EQ.OutNode) THEN
        IF (UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil .AND. UnitarySystem(UnitarySysNum)%RunOnSensibleLoad) THEN
          CALL FrostControlSetPointLimit(UnitarySysNum, Node(ControlNode)%TempSetPoint,Node(ControlNode)%HumRatMax,OutBaroPress, &
                                         UnitarySystem(UnitarySysNum)%DOASDXCoolingCoilMinTout,1)
        END IF
        UnitarySystem(UnitarySysNum)%DesiredOutletTemp = Node(ControlNode)%TempSetPoint
        !  IF HumRatMax is zero, then there is no request from SetpointManager:SingleZone:Humidity:Maximum
        IF ((UnitarySystem(UnitarySysNum)%DehumidControlType_Num .NE. DehumidControl_None) .AND. &
            (Node(ControlNode)%HumRatMax .GT. 0.0d0)) THEN
          IF (UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil .AND. UnitarySystem(UnitarySysNum)%RunOnLatentLoad) THEN
            CALL FrostControlSetPointLimit(UnitarySysNum,Node(ControlNode)%TempSetPoint,Node(ControlNode)%HumRatMax,OutBaroPress, &
                                           UnitarySystem(UnitarySysNum)%DOASDXCoolingCoilMinTout,2)
          END IF
          UnitarySystem(UnitarySysNum)%DesiredOutletHumRat = Node(ControlNode)%HumRatMax
        ELSE
          UnitarySystem(UnitarySysNum)%DesiredOutletHumRat = 1.0d0
        END IF
      ELSE
        IF (UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil .AND. UnitarySystem(UnitarySysNum)%RunOnSensibleLoad) THEN
          CALL FrostControlSetPointLimit(UnitarySysNum,Node(ControlNode)%TempSetPoint,Node(ControlNode)%HumRatMax,OutBaroPress, &
                                         UnitarySystem(UnitarySysNum)%DOASDXCoolingCoilMinTout,1)
        END IF
        UnitarySystem(UnitarySysNum)%DesiredOutletTemp = Node(ControlNode)%TempSetPoint - &
          (Node(ControlNode)%Temp - Node(OutNode)%Temp)
        IF (UnitarySystem(UnitarySysNum)%DehumidControlType_Num .NE. DehumidControl_None) THEN
          IF (UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil .AND. UnitarySystem(UnitarySysNum)%RunOnLatentLoad) THEN
            CALL FrostControlSetPointLimit(UnitarySysNum,Node(ControlNode)%TempSetPoint,Node(ControlNode)%HumRatMax,OutBaroPress, &
                                           UnitarySystem(UnitarySysNum)%DOASDXCoolingCoilMinTout,2)
          END IF
          UnitarySystem(UnitarySysNum)%DesiredOutletHumRat = Node(ControlNode)%HumRatMax - &
            (Node(ControlNode)%HumRat - Node(OutNode)%HumRat)
        ELSE
          UnitarySystem(UnitarySysNum)%DesiredOutletHumRat = 1.0d0
        END IF
      END IF
    END IF
    IF(PRESENT(MaxOutletTemp))UnitarySystem(UnitarySysNum)%DesiredOutletTemp = &
        MIN(UnitarySystem(UnitarySysNum)%DesiredOutletTemp,MaxOutletTemp)

  CASE DEFAULT

END SELECT

RETURN
END SUBROUTINE UpdateUnitarySystemControl

SUBROUTINE InitLoadBasedControl(UnitarySysNum,AirLoopNum,FirstHVACIteration,OnOffAirFlowRatio,ZoneLoad)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine is for initializations of the load controlled Unitary Systems.

          ! METHODOLOGY EMPLOYED:
          ! Initialize mass flow rates and speed ratios. Calculate loads and adjust if necessary when using constant fan.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DataAirLoop,           ONLY: AirLoopControlInfo, AirToZoneNodeInfo
  USE Fans,                  ONLY: GetFanDesignVolumeFlowRate, GetFanSpeedRatioCurveIndex
  USE General,               ONLY: RoundSigDigits, TrimSigDigits
  USE DataHeatBalance,       ONLY: Zone
  USE DataHeatBalFanSys,     ONLY: TempControlType
  USE DataAirflowNetwork,    ONLY: SimulateAirflowNetwork, AirflowNetworkControlMultizone, AirflowNetworkFanActivated
  USE Psychrometrics,        ONLY: PsyHFnTdbW
  USE ReportSizingManager,   ONLY: ReportSizingOutput
  USE WaterCoils,            ONLY: GetCoilMaxWaterFlowRate, SimulateWaterCoilComponents
  USE SteamCoils,            ONLY: GetCoilMaxSteamFlowRate, SimulateSteamCoilComponents
  USE DataPlant,             ONLY: PlantLoop
  USE FluidProperties,       ONLY: GetDensityGlycol, GetSatDensityRefrig
  USE PlantUtilities,        ONLY: SetComponentFlowRate, InitComponentNodes
  USE DataZoneEnergyDemands, ONLY: ZoneSysEnergyDemand, CurDeadbandOrSetback, SetBack
  USE DataZoneControls,      ONLY: StageZoneLogic
  USE BranchInputManager,    ONLY: CheckSystemBranchFlow

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT (IN)      :: UnitarySysNum       ! number of the current DX Sys being simulated
  INTEGER, INTENT (IN)      :: AirLoopNum          ! number of the current air loop being simulated
  LOGICAL, INTENT (IN)      :: FirstHVACIteration
  REAL(R64), INTENT (INOUT) :: OnOffAirFlowRatio
  REAL(r64), INTENT (INOUT) :: ZoneLoad

          ! SUBROUTINE PARAMETER DEFINITIONS:
  REAL(r64), PARAMETER :: Small5WLoad = 5.0d0

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  LOGICAL, ALLOCATABLE,SAVE, DIMENSION(:) :: MyEnvrnFlag             ! environment flag
  LOGICAL, ALLOCATABLE,SAVE, DIMENSION(:) :: MyFanFlag               ! used for sizing fan inputs one time
  LOGICAL, ALLOCATABLE,SAVE, DIMENSION(:) :: MyCheckFlag             ! Used to obtain the zone inlet node number
                                                                     ! in the controlled zone
  LOGICAL, ALLOCATABLE,SAVE, DIMENSION(:) :: MyFlowFracFlag          ! Used for calculatig flow fraction once
  LOGICAL, ALLOCATABLE,SAVE, DIMENSION(:) :: MyStagedFlag            ! used for finding on staged thermostat
  LOGICAL, SAVE                 :: MyOneTimeFlag = .TRUE.  ! one time allocation flag
  LOGICAL, SAVE                 :: MyAirLoopPass = .TRUE.  ! one time allocation flag
  INTEGER                       :: AirLoopPass   = 0       ! Number of air loop pass
  CHARACTER(len=MaxNameLength)  :: FanType                 ! used in warning messages
  CHARACTER(len=MaxNameLength)  :: FanName                 ! used in warning messages
  LOGICAL                       :: ErrFlag                 ! error flag for mining functions
  LOGICAL                       :: ErrorsFound             ! error flag for mining functions
  INTEGER                       :: ZoneInNode              ! Zone inlet node number in the controlled zone
  REAL(r64)                     :: MinHumRat               ! Minimum humidity ratio for sensible capacity calculation (kg/kg)
  REAL(r64)                     :: DeltaMassRate           ! DIFference of mass flow rate between
                                                           ! inlet node and system outlet node
  INTEGER                       :: i,j,k                   ! index to get the zone inlet node
  REAL(r64)                     :: MassFlowRate            ! mass flow rate to calculate loss
  REAL(r64)                     :: MaxTemp                 ! Maximum temperature used in latent loss calculation
  INTEGER                       :: EquipNum              = 0                    ! local DO loop index for zone equipment
  INTEGER                       :: ZoneInSysIndex        = 0                    ! number of zone inlet nodes counter in an airloop
  INTEGER                       :: NumAirLoopZones       = 0                    ! number of zone inlet nodes in an air loop
  INTEGER                       :: ZoneInletNodeNum      = 0                    ! zone inlet nodes node number
  LOGICAL                       :: FlowFracFlagReady     = .TRUE.               ! one time flag for calculating flow fraction
  REAL(r64)                     :: SumOfMassFlowRateMax  = 0.0d0                ! the sum of zone inlet mass flow rates
  REAL(r64)                     :: CntrlZoneTerminalUnitMassFlowRateMax = 0.0d0 ! Maximum mass flow rate through controlled zone
  REAL(R64)                     :: rho
  REAL(R64)                     :: QZnReq
  REAL(R64)                     :: QActual
  REAL(R64)                     :: CoilMaxVolFlowRate
  INTEGER                       :: SteamIndex
  REAL(R64)                     :: SteamDensity
  REAL(R64)                     :: SensOutputOff
  REAL(R64)                     :: LatOutputOff
  LOGICAL                       :: HXUnitOn

  IF (MyOneTimeFlag) THEN

    ! initialize the environment and sizing flags
    ALLOCATE(MyEnvrnFlag(NumUnitarySystem))
    ALLOCATE(MyFanFlag(NumUnitarySystem))
    ALLOCATE(MyCheckFlag(NumUnitarySystem))
    ALLOCATE(MyFlowFracFlag(NumUnitarySystem))
    ALLOCATE(MyStagedFlag(NumUnitarySystem))

    MyEnvrnFlag = .TRUE.
    MyFanFlag = .TRUE.
    MyCheckFlag = .TRUE.
    MyFlowFracFlag = .TRUE.
    MyOneTimeFlag = .FALSE.
    MyStagedFlag = .TRUE.

  END IF

! do the Begin Environment initializations
  IF (BeginEnvrnFlag .and. MyEnvrnFlag(UnitarySysNum)) THEN

!   set fluid-side hardware limits
    IF(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode .GT. 0)THEN

        IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow .EQ. Autosize)THEN
            ! IF water coil max water flow rate is autosized, simulate once in order to mine max flow rate
            IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWater) THEN
                CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%HeatingCoilName,FirstHVACIteration, &
                                                UnitarySystem(UnitarySysNum)%HeatingCoilIndex)
                CoilMaxVolFlowRate = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                                             UnitarySystem(UnitarySysNum)%HeatingCoilName,ErrorsFound)
                IF(CoilMaxVolFlowRate .NE. Autosize) THEN
                    rho = GetDensityGlycol(PlantLoop(UnitarySystem(UnitarySysNum)%HeatCoilLoopNum)%fluidName, &
                                            InitConvTemp, &
                                            PlantLoop(UnitarySystem(UnitarySysNum)%HeatCoilLoopNum)%fluidIndex, &
                                            'InitUnitarySystems')
                    UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow = CoilMaxVolFlowRate * rho
                END IF
            END IF
            ! IF steam coil max steam flow rate is autosized, simulate once in order to mine max flow rate
            IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingSteam) THEN
                CALL SimulateSteamCoilComponents(UnitarySystem(UnitarySysNum)%HeatingCoilName, &
                                                FirstHVACIteration,    &
                                                1.0d0, & !QCoilReq, simulate any load > 0 to get max capacity
                                                UnitarySystem(UnitarySysNum)%HeatingCoilIndex, QActual)
                CoilMaxVolFlowRate = GetCoilMaxSteamFlowRate(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrorsFound)
                IF(CoilMaxVolFlowRate .NE. Autosize) THEN
                   SteamIndex = 0 ! Function GetSatDensityRefrig will look up steam index if 0 is passed
                   SteamDensity=GetSatDensityRefrig('STEAM',TempSteamIn,1.0d0,SteamIndex,'InitUnitarySystems')
                   UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow = CoilMaxVolFlowRate * SteamDensity
                END IF
            END IF
        END IF

        CALL InitComponentNodes(0.0d0, UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilLoopNum, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilLoopSide, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilBranchNum, &
                                        UnitarySystem(UnitarySysNum)%HeatCoilCompNum )
    END IF
    IF(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode .GT. 0)THEN
        IF(UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow .EQ. Autosize)THEN
            IF(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingWater) THEN
                ! IF water coil max water flow rate is autosized, simulate once in order to mine max flow rate
                CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%SuppHeatCoilName,FirstHVACIteration, &
                                                UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex)
                CoilMaxVolFlowRate = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                                            UnitarySystem(UnitarySysNum)%SuppHeatCoilName,ErrorsFound)
                IF(CoilMaxVolFlowRate .NE. Autosize) THEN
                    rho = GetDensityGlycol(PlantLoop(UnitarySystem(UnitarySysNum)%SuppCoilLoopNum)%fluidName, &
                                        InitConvTemp, &
                                        PlantLoop(UnitarySystem(UnitarySysNum)%SuppCoilLoopNum)%fluidIndex, &
                                        'InitUnitarySystems')
                    UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow = CoilMaxVolFlowRate * rho
                END IF
            END IF
            IF(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingSteam) THEN
                CALL SimulateSteamCoilComponents(UnitarySystem(UnitarySysNum)%SuppHeatCoilName, &
                                                FirstHVACIteration,    &
                                                1.0d0, & !QCoilReq, simulate any load > 0 to get max capacity
                                                UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, QActual)
                CoilMaxVolFlowRate = GetCoilMaxSteamFlowRate(UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,ErrorsFound)
                IF(CoilMaxVolFlowRate .NE. Autosize) THEN
                SteamIndex = 0 ! Function GetSatDensityRefrig will look up steam index if 0 is passed
                SteamDensity=GetSatDensityRefrig('STEAM',TempSteamIn,1.0d0,SteamIndex,'InitUnitarySystems')
                UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow = CoilMaxVolFlowRate * SteamDensity
                END IF
            END IF
            CALL InitComponentNodes(0.0d0, UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilLoopNum, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilLoopSide, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilBranchNum, &
                                        UnitarySystem(UnitarySysNum)%SuppCoilCompNum )
        END IF
    END IF
    MyEnvrnFlag(UnitarySysNum) = .FALSE.
  END IF

  IF (.not. BeginEnvrnFlag) THEN
    MyEnvrnFlag(UnitarySysNum) = .TRUE.
  END IF

  IF(MyFanFlag(UnitarySysNum))THEN
    IF(UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate /= Autosize)THEN
      IF(UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate .GT. 0.0d0)THEN
        UnitarySystem(UnitarySysNum)%HeatingFanSpeedRatio = &
                  UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow/UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate
        UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio = &
                  UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow/UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate
        UnitarySystem(UnitarySysNum)%NoHeatCoolSpeedRatio = &
                  UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow/UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate
        IF(UnitarySystem(UnitarySysNum)%FanExists)THEN
          IF(GetFanSpeedRatioCurveIndex(FanType,FanName,UnitarySystem(UnitarySysNum)%FanIndex) .GT. 0)THEN
            IF(UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate .EQ. UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .AND. &
               UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate .EQ. UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .AND. &
               UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate .EQ. UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow)THEN
              CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                                ' "'//TRIM(UnitarySystem(UnitarySysNum)%Name)//'"')
              CALL ShowContinueError('...For fan type and name = '//TRIM(FanType)//' "'//TRIM(FanName)//'"')
              CALL ShowContinueError('...Fan power ratio function of speed ratio curve has no impact IF fan volumetric '// &
                                 'flow rate is the same as the unitary system volumetric flow rate.')
              CALL ShowContinueError('...Fan volumetric flow rate            = '// &
                                 TRIM(RoundSigDigits(UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate,5))//' m3/s.')
              CALL ShowContinueError('...Unitary system volumetric flow rate = '// &
                                 TRIM(RoundSigDigits(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow,5))//' m3/s.')
            END IF
          END IF
        ELSE
          CALL CheckSystemBranchFlow(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType),UnitarySystem(UnitarySysNum)%Name, &
                               UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate,0.0d0,ErrFlag)
        END IF
      END IF
      MyFanFlag(UnitarySysNum) = .FALSE.
    ELSE
      IF(UnitarySystem(UnitarySysNum)%FanExists)THEN
        UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate = &
          GetFanDesignVolumeFlowRate(Blank,Blank,ErrFlag,UnitarySystem(UnitarySysNum)%FanIndex)
      ELSE
        CALL CheckSystemBranchFlow(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType),UnitarySystem(UnitarySysNum)%Name, &
                               UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate,0.0d0,ErrFlag)
      END IF
    END IF
  END IF

  ! Get the zone inlet node
  IF (ALLOCATED(ZoneEquipConfig) .AND. MyCheckFlag(UnitarySysNum)) THEN
    DO i=1,NumOfZones
      IF(UnitarySystem(UnitarySysNum)%AirLoopEquipment)THEN
        IF (AirLoopNum .NE. ZoneEquipConfig(i)%AirLoopNum) CYCLE
        IF (UnitarySystem(UnitarySysNum)%ControlZoneNum .EQ. ZoneEquipConfig(i)%ActualZoneNum) THEN
          DO j=1, ZoneEquipConfig(i)%NumInletNodes
            IF (UnitarySystem(UnitarySysNum)%ZoneInletNode .EQ. 0) THEN
              DO k=1,ZoneEquipConfig(i)%NumInletNodes
                IF (ZoneEquipConfig(i)%InletNode(j) .EQ. ZoneEquipConfig(i)%AirDistUnitCool(k)%OutNode) THEN
                  UnitarySystem(UnitarySysNum)%ZoneInletNode = ZoneEquipConfig(i)%InletNode(j)
                  EXIT
                ELSEIF (ZoneEquipConfig(i)%InletNode(j) .EQ. ZoneEquipConfig(i)%AirDistUnitHeat(k)%OutNode) THEN
                  UnitarySystem(UnitarySysNum)%ZoneInletNode = ZoneEquipConfig(i)%InletNode(j)
                  EXIT
                END IF
              END DO
            END IF
          END DO
          !setup unitary system zone equipment sequence information based on finding an air terminal
          IF (ZoneEquipConfig(i)%EquipListIndex > 0) THEN
            DO EquipNum = 1, ZoneEquipList(ZoneEquipConfig(i)%EquipListIndex)%NumOfEquipTypes
              IF ((ZoneEquipList(ZoneEquipConfig(i)%EquipListIndex)%EquipType_Num(EquipNum) == AirDistUnit_Num) &
                  .OR. (ZoneEquipList(ZoneEquipConfig(i)%EquipListIndex)%EquipType_Num(EquipNum) == DirectAir_Num) ) THEN
                UnitarySystem(UnitarySysNum)%ZoneSequenceCoolingNum = &
                         ZoneEquipList(ZoneEquipConfig(i)%EquipListIndex)%CoolingPriority(EquipNum)
                UnitarySystem(UnitarySysNum)%ZoneSequenceHeatingNum = &
                         ZoneEquipList(ZoneEquipConfig(i)%EquipListIndex)%HeatingPriority(EquipNum)
              END IF
            END DO
          END IF
        END IF
      END IF
    END DO
    MyCheckFlag(UnitarySysNum) = .FALSE.
    IF (UnitarySystem(UnitarySysNum)%ZoneInletNode .EQ. 0) THEN
      CALL ShowSevereError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'//TRIM(UnitarySystem(UnitarySysNum)%Name)// &
                             '": The zone inlet node in the controlled zone (' &
                            //Trim(Zone(UnitarySystem(UnitarySysNum)%ControlZoneNum)%Name) //') is not found.')
      CALL ShowFatalError('Subroutine InitLoadBasedControl: '//'Errors found in getting '// &
           TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' input.  '//'Preceding condition(s) causes termination.')
    END IF
  END IF

  ! Find the number of zones (zone Inlet Nodes) attached to an air loop from the air loop number
  IF(MyFlowFracFlag(UnitarySysNum))THEN
    IF(UnitarySystem(UnitarySysNum)%AirLoopEquipment)THEN
      IF(ALLOCATED(AirToZoneNodeInfo))NumAirLoopZones = &
        AirToZoneNodeInfo(AirLoopNum)%NumZonesCooled + AirToZoneNodeInfo(AirLoopNum)%NumZonesHeated
      IF (ALLOCATED(AirToZoneNodeInfo) .AND. MyFlowFracFlag(UnitarySysNum)) THEN
        FlowFracFlagReady = .TRUE.
        ZonesLoop: DO ZoneInSysIndex = 1, NumAirLoopZones
          ! zone inlet nodes for cooling
          IF (AirToZoneNodeInfo(AirLoopNum)%NumZonesCooled > 0) THEN
            IF( AirToZoneNodeInfo(AirLoopNum)%TermUnitCoolInletNodes(ZoneInSysIndex) == -999 )THEN
              ! the data structure for the zones inlet nodes has not been filled
              FlowFracFlagReady = .FALSE.
            END IF
          END IF
          ! zone inlet nodes for heating
          IF (AirToZoneNodeInfo(AirLoopNum)%NumZonesHeated  > 0) THEN
            IF( AirToZoneNodeInfo(AirLoopNum)%TermUnitHeatInletNodes(ZoneInSysIndex) == -999 ) THEN
              ! the data structure for the zones inlet nodes has not been filled
              FlowFracFlagReady = .FALSE.
            END IF
          END IF
        END DO ZonesLoop
      END IF
      IF (ALLOCATED(AirToZoneNodeInfo) .AND. FlowFracFlagReady ) THEN
        SumOfMassFlowRateMax = 0.0d0  ! initialize the sum of the maximum flows
        DO ZoneInSysIndex = 1, NumAirLoopZones
          ZoneInletNodeNum = AirToZoneNodeInfo(AirLoopNum)%TermUnitCoolInletNodes(ZoneInSysIndex)
          SumOfMassFlowRateMax = SumOfMassFlowRateMax + Node(ZoneInletNodeNum)%MassFlowRateMax
          IF(AirToZoneNodeInfo(AirLoopNum)%CoolCtrlZoneNums(ZoneInSysIndex) == UnitarySystem(UnitarySysNum)%ControlZoneNum )THEN
            CntrlZoneTerminalUnitMassFlowRateMax = Node(ZoneInletNodeNum)%MassFlowRateMax
          END IF
        END DO
        IF (SumOfMassFlowRateMax /= 0.0d0 .AND. MyFlowFracFlag(UnitarySysNum)) THEN
          IF (CntrlZoneTerminalUnitMassFlowRateMax >= SmallAirVolFlow ) THEN
              UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac = CntrlZoneTerminalUnitMassFlowRateMax/SumOfMassFlowRateMax
          ELSE
            CALL ShowSevereError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' = '// &
                                 TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError(' The Fraction of Supply Air Flow That Goes Through the Controlling Zone is set to 1.')
          END IF
          CALL ReportSizingOutput(UnitarySystem(UnitarySysNum)%UnitarySystemType,UnitarySystem(UnitarySysNum)%Name, &
                                  'Fraction of Supply Air Flow That Goes Through the Controlling Zone', &
                                  UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac)
          MyFlowFracFlag(UnitarySysNum) = .FALSE.
        END IF
      END IF
    ELSE
      UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac = 1.0d0
    END IF
  END IF ! IF(MyFlowFracFlag(UnitarySysNum))THEN

! What type of logic is this? Is the point to go through the main IF once? or every other time?
  IF (BeginEnvrnFlag .and. MyAirLoopPass) THEN
    AirLoopPass = 0
    MyAirLoopPass = .FALSE.
  END IF
  IF (.not. BeginEnvrnFlag) THEN
    MyAirLoopPass = .TRUE.
  END IF

  AirLoopPass = AirLoopPass + 1
  IF (AirLoopPass > 2) AirLoopPass = 1

  ! reset duct losses from previous iteration
  IF (FirstHVACIteration) THEN
    UnitarySystem(UnitarySysNum)%SenLoadLoss = 0.0d0
    UnitarySystem(UnitarySysNum)%LatLoadLoss = 0.0d0
  END IF

  ! Calcuate air distribution losses
!  IF (.NOT. FirstHVACIteration .AND. AirLoopPass .EQ. 1 .AND. AirflowNetworkFanActivated) THEN
  IF (.NOT. FirstHVACIteration .AND. AirflowNetworkFanActivated) THEN
    ZoneInNode = UnitarySystem(UnitarySysNum)%ZoneInletNode
    MinHumRat = Node(ZoneInNode)%HumRat
    MassFlowRate = Node(ZoneInNode)%MassFlowrate/UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac
    IF(Node(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)%Temp .LT. &
       Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%Temp ) &
      MinHumRat = Node(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)%HumRat
    IF (SimulateAirflowNetwork > AirflowNetworkControlMultizone) THEN
      DeltaMassRate = Node(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)%MassFlowrate - &
                    Node(ZoneInNode)%MassFlowrate/UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac
      IF (DeltaMassRate .LT. 0.0d0) DeltaMassRate = 0.0d0
    ELSE
      MassFlowRate = Node(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)%MassFlowrate
      DeltaMassRate = 0.0d0
    END IF
    UnitarySystem(UnitarySysNum)%SenLoadLoss = &
       MassFlowRate * (PsyHFnTdbW(Node(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)%Temp,MinHumRat)- &
       PsyHFnTdbW(Node(ZoneInNode)%Temp,MinHumRat)) + DeltaMassRate * &
      (PsyHFnTdbW(Node(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)%Temp,MinHumRat) - &
       PsyHFnTdbW(Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%Temp,MinHumRat))
    IF (ABS(UnitarySystem(UnitarySysNum)%SensibleLoadMet) > 0.0d0) THEN
      IF (ABS(UnitarySystem(UnitarySysNum)%SenLoadLoss/UnitarySystem(UnitarySysNum)%SensibleLoadMet) < 0.001d0) &
           UnitarySystem(UnitarySysNum)%SenLoadLoss = 0.0d0
    END IF
    IF(UnitarySystem(UnitarySysNum)%Humidistat)THEN
      MaxTemp = Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%Temp
      UnitarySystem(UnitarySysNum)%LatLoadLoss = &
        MassFlowRate*(PsyHFnTdbW(MaxTemp,Node(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)%HumRat)- &
        PsyHFnTdbW(MaxTemp,Node(ZoneInNode)%HumRat)) + DeltaMassRate * &
        (PsyHFnTdbW(MaxTemp,Node(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)%HumRat) - &
        PsyHFnTdbW(MaxTemp,Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%HumRat))
      IF (ABS(UnitarySystem(UnitarySysNum)%LatentLoadMet) > 0.0d0) THEN
        IF (ABS(UnitarySystem(UnitarySysNum)%LatLoadLoss/UnitarySystem(UnitarySysNum)%LatentLoadMet) < 0.001d0) &
             UnitarySystem(UnitarySysNum)%LatLoadLoss = 0.0d0
      END IF
    END IF
  END IF

  IF (UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr .GT. 0) THEN
    IF (GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr) .EQ. 0.0d0) THEN
      UnitarySystem(UnitarySysNum)%FanOpMode = CycFanCycCoil
    ELSE
      UnitarySystem(UnitarySysNum)%FanOpMode = ContFanCycCoil
      OnOffFanPartLoadFraction = 1.0d0
    END IF
  END IF

!  OpMode = UnitarySystem(UnitarySysNum)%FanOpMode
  IF(ALLOCATED(AirLoopControlInfo) .AND. UnitarySystem(UnitarySysNum)%AirLoopEquipment)THEN
    EconomizerFlag = AirLoopControlInfo(AirLoopNum)%EconoActive
  ELSE
    EconomizerFlag = .FALSE.
  END IF

! System load calculation for cycling fan systems
  IF(UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac .GT. 0.0d0)THEN
    QZnReq = ZoneLoad/UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac
    MoistureLoad = MoistureLoad/UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac
    QToCoolSetPt=QToCoolSetPt/UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac
    QToHeatSetPt=QToHeatSetPt/UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac
    ZoneLoad = QZnReq
  ELSE
    QZnReq = ZoneLoad
    UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac = 1.0d0
  END IF

  CoolingLoad = .FALSE.
  HeatingLoad = .FALSE.

  IF(QZnReq .GT.  Small5WLoad/UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac .AND. &
     .NOT. CurDeadbandOrSetback(UnitarySystem(UnitarySysNum)%ControlZoneNum))THEN
    IF(TempControlType(UnitarySystem(UnitarySysNum)%ControlZoneNum) .NE. SingleCoolingSetPoint)THEN
      HeatingLoad = .TRUE.
    END IF
  ELSEIF(QZnReq .LT. -Small5WLoad/UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac .AND. &
     .NOT. CurDeadbandOrSetback(UnitarySystem(UnitarySysNum)%ControlZoneNum))THEN
    IF(TempControlType(UnitarySystem(UnitarySysNum)%ControlZoneNum) .NE. SingleHeatingSetPoint)THEN
      CoolingLoad = .TRUE.
    END IF
  END IF

! System load calculation for constant fan systems
  IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
    HXUnitOn = .FALSE.
    CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,0.0d0,0.0d0, &
                                 OnOffAirFlowRatio,SensOutputOff,LatOutputOff,HXUnitOn)
    SELECT CASE(TempControlType(UnitarySystem(UnitarySysNum)%ControlZoneNum))
    CASE(SingleHeatingSetPoint)
      CoolingLoad = .FALSE.
      ! No heating load and constant fan pushes zone below heating set point
      IF(SensOutputOff .LT. 0.0d0 .AND. QToHeatSetPt .LT. 0.0d0 .AND. &
         SensOutputOff-QToHeatSetPt .LT. -SmallLoad)THEN
        HeatingLoad = .TRUE.
        CoolingLoad = .FALSE.
        ZoneLoad = QToHeatSetPt
      END IF
    CASE(SingleCoolingSetPoint)
      HeatingLoad = .FALSE.
      ! No heating load and constant fan pushes zone above cooling set point
      IF(SensOutputOff .GT. 0.0d0 .AND. QToCoolSetPt .GT. 0.0d0 .AND. &
         SensOutputOff-QToCoolSetPt .GT. SmallLoad)THEN
        HeatingLoad = .FALSE.
        CoolingLoad = .TRUE.
        ZoneLoad = QToCoolSetPt
      END IF
    CASE(SingleHeatCoolSetPoint)
      ! zone temp above cooling and heating set point temps
      IF(QToHeatSetPt .LT. 0.0d0 .AND. QToCoolSetPt .LT. 0.0d0)THEN
        ! zone pushed below heating set point
        IF(SensOutputOff .LT. 0.0d0 .AND. &
           QToHeatSetPt-SensOutputOff .GT. SmallLoad)THEN
          HeatingLoad = .TRUE.
          CoolingLoad = .FALSE.
          ZoneLoad = QToHeatSetPt
        END IF
      ! zone temp below heating set point temp
      ELSEIF(QToHeatSetPt .GT. 0.0d0 .AND. QToCoolSetPt .GT. 0.0d0)THEN
        ! zone pushed above cooling set point
        IF(SensOutputOff .GT. 0.0d0 .AND. &
           QToCoolSetPt-SensOutputOff .GT. SmallLoad)THEN
          HeatingLoad = .FALSE.
          CoolingLoad = .TRUE.
          ZoneLoad = QToCoolSetPt
        END IF
      END IF
    CASE(DualSetPointWithDeadBand)
      ! zone temp above cooling and heating set point temps
      IF(QToHeatSetPt .LT. 0.0d0 .AND. QToCoolSetPt .LT. 0.0d0)THEN
        ! zone pushed into deadband
        IF(SensOutputOff .LT. 0.0d0 .AND. &
           QToCoolSetPt-SensOutputOff .GT. SmallLoad)THEN
          HeatingLoad = .FALSE.
          CoolingLoad = .FALSE.
          ZoneLoad = 0.0d0
        END IF
        ! zone pushed below heating set point
        IF(SensOutputOff .LT. 0.0d0 .AND. &
           QToHeatSetPt-SensOutputOff .GT. SmallLoad)THEN
          HeatingLoad = .TRUE.
          CoolingLoad = .FALSE.
          ZoneLoad = QToHeatSetPt
        END IF
      ! zone temp below heating set point temp
      ELSEIF(QToHeatSetPt .GT. 0.0d0 .AND. QToCoolSetPt .GT. 0.0d0)THEN
        ! zone pushed into deadband
        IF(SensOutputOff .GT. 0.0d0 .AND. &
           SensOutputOff-QToHeatSetPt .GT. SmallLoad)THEN
          HeatingLoad = .FALSE.
          CoolingLoad = .FALSE.
          ZoneLoad = 0.0d0
        END IF
        ! zone pushed above cooling set point
        IF(SensOutputOff .GT. 0.0d0 .AND. &
           SensOutputOff-QToCoolSetPt .GT. SmallLoad)THEN
          HeatingLoad = .FALSE.
          CoolingLoad = .TRUE.
          ZoneLoad = QToCoolSetPt
        END IF
      ! zone temp between set point temps
      ELSEIF(QToHeatSetPt .LT. 0.0d0 .AND. QToCoolSetPt .GT. 0.0d0)THEN
        ! zone pushed below heating set point
        IF(SensOutputOff .LT. 0.0d0 .AND. &
           SensOutputOff-QToHeatSetPt .LT. -SmallLoad)THEN
          HeatingLoad = .TRUE.
          CoolingLoad = .FALSE.
          ZoneLoad = QToHeatSetPt
        ! zone pushed above cooling set point
        ELSEIF(SensOutputOff .GT. 0.0d0 .AND. &
                SensOutputOff-QToCoolSetPt .GT. SmallLoad)THEN
          HeatingLoad = .FALSE.
          CoolingLoad = .TRUE.
          ZoneLoad = QToCoolSetPt
        END IF
      END IF
    CASE DEFAULT
    END SELECT

    ! IF small loads to meet, just shut down unit
    IF(ABS(ZoneLoad) < Small5WLoad)THEN
      ZoneLoad = 0.0d0
      CoolingLoad = .FALSE.
      HeatingLoad = .FALSE.
    END IF

  END IF

  ! Determine the staged status
  IF (ALLOCATED(StageZoneLogic) .AND.  UnitarySystem(UnitarySysNum)%DesignSpecMSHPIndex > 0) THEN
    IF (StageZoneLogic(UnitarySystem(UnitarySysNum)%ControlZoneNum)) THEN
      UnitarySystem(UnitarySysNum)%Staged = .TRUE.
      UnitarySystem(UnitarySysNum)%StageNum = ZoneSysEnergyDemand(UnitarySystem(UnitarySysNum)%ControlZoneNum)%StageNum
    ELSE
      IF (MyStagedFlag(UnitarySysNum)) THEN
        CALL ShowWarningError('ZoneControl:Thermostat:StagedDualSetpoint is found, but is not applied to '// &
             'this AirLoopHVAC:UnitarySystem object with UnitarySystemPerformance:HeatPump:Multispeed type = ')
        CALL ShowContinueError(Trim(UnitarySystem(UnitarySysNum)%Name) //'. Please make correction. Simulation continues...')
        MyStagedFlag(UnitarySysNum) = .FALSE.
      END IF
    END IF
  END IF

  ! Staged control
  IF (UnitarySystem(UnitarySysNum)%Staged) THEN
    IF (UnitarySystem(UnitarySysNum)%StageNum == 0) THEN
      HeatingLoad = .FALSE.
      CoolingLoad = .FALSE.
      QZnReq = 0.0d0
    ELSE
      QZnReq = ZoneSysEnergyDemand(UnitarySystem(UnitarySysNum)%ControlZoneNum)%RemainingOutputRequired/ &
               UnitarySystem(UnitarySysNum)%ControlZoneMassFlowFrac
      IF (UnitarySystem(UnitarySysNum)%StageNum > 0) THEN
        HeatingLoad = .TRUE.
        CoolingLoad = .FALSE.
      ELSE
        HeatingLoad = .FALSE.
        CoolingLoad = .TRUE.
      END IF
    END IF
  END IF

  IF(UnitarySystem(UnitarySysNum)%DehumidControlType_Num == DehumidControl_MultiMode) THEN
    IF(HeatingLoad)MoistureLoad = 0.0d0
  END IF

  ! Check load control
  IF(UnitarySystem(UnitarySysNum)%RunOnLatentOnlyWithSensible .AND. ZoneLoad == 0.0d0)MoistureLoad = 0.0d0
  IF(.NOT. UnitarySystem(UnitarySysNum)%RunOnSensibleLoad)THEN
    ZoneLoad = 0.0d0
    CoolingLoad = .FALSE.
    HeatingLoad = .FALSE.
  END IF
  IF(.NOT. UnitarySystem(UnitarySysNum)%RunOnLatentLoad)MoistureLoad = 0.0d0

  ! Testing heat pump air to air with RH control with CoolReheat dehumidifaction control showed that when there was heating
  ! and moisture load, the cooling coil was turning on to meet the moisture load and reheat was then turning on to meet both
  ! heating load and excess cooling load caused by cooling coil. Adding the logic below caused the zone temperature,
  ! relative humidity, cooling/heating rate to line up for both the orignal and new file with unitary system object.

   IF(UnitarySystem(UnitarySysNum)%SuppCoilExists)THEN
     IF(UnitarySystem(UnitarySysNum)%DehumidControlType_Num == DehumidControl_CoolReheat) THEN
       IF (MoistureLoad < 0.0d0 .AND. UnitarySystem(UnitarySysNum)%HeatPump) THEN
         HeatingLoad = .FALSE.
         CoolingLoad = .TRUE.
       END IF
     END IF
   END IF

RETURN
END SUBROUTINE InitLoadBasedControl

! End of Initialization subroutines for the Module
! *****************************************************************************

SUBROUTINE SizeUnitarySystem(UnitarySysNum, FirstHVACIteration, AirLoopNum)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine is for sizing unitary system components for which nominal cpacities
          ! and flow rates have not been specified in the input. Coil sizing is preformed in the coil module.
          ! Future modifications will size coils here and "push" this info to the specific coil.

          ! METHODOLOGY EMPLOYED:
          ! Obtains heating capacities and flow rates from the zone or system sizing arrays.
          !
          ! NOTE: In UNITARYSYSTEM:HEATPUMP:AIRTOAIR we are sizing the heating capacity to be
          ! equal to the cooling capacity.  Thus the cooling and
          ! and heating capacities of a DX heat pump system will be identical. In real life the ARI
          ! heating and cooling capacities are close but not identical.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE BranchInputManager,        ONLY: CheckSystemBranchFlow, GetAirBranchIndex, GetBranchFanTypeName, GetBranchFlow
  USE DataAirSystems,            ONLY: PrimaryAirSystem
  USE CurveManager,              ONLY: CurveValue
  USE DXCoils,                   ONLY: SimDXCoil, SimDXCoilMultiSpeed, GetCoilCapacityByIndexType, &
                                       GetDXCoilCapFTCurveIndex !, SetDXCoolingCoilData
  USE Fans,                      ONLY: GetFanDesignVolumeFlowRate
  USE HVACHXAssistedCoolingCoil, ONLY: SimHXAssistedCoolingCoil,GetCoilCapacity,GetHXDXCoilName,GetCoilObjectTypeNum
  USE ReportSizingManager,       ONLY: ReportSizingOutput
  USE VariableSpeedCoils,        ONLY: SimVariableSpeedCoils, VarSpeedCoil, GetCoilCapacityVariableSpeed
  USE WatertoAirHeatPump,        ONLY: SimWaterToAirHP,GetWAHPCoilCapacity=>GetCoilCapacity
  USE WatertoAirHeatPumpSimple,  ONLY: SimWatertoAirHPSimple,GetSimpleCoilCapacity=>GetCoilCapacity
  USE PlantUtilities,            ONLY: RegisterPlantCompDesignFlow
  USE InputProcessor,            ONLY: SameString, FindItemInList,MakeUPPERCase
  USE General,                   ONLY: TrimSigDigits
  USE WaterCoils,                ONLY: SetCoilDesFlow,GetWaterCoilCapacity
  USE Psychrometrics
  USE HVACDXSystem,              ONLY: GetCoolingCoilTypeNameAndIndex
  USE EMSManager,                ONLY: ManageEMS
  USE DataGlobals,               ONLY: emsCallFromUnitarySystemSizing

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN) :: UnitarySysNum
  LOGICAL, INTENT(IN) :: FirstHVACIteration
  INTEGER, INTENT(IN) :: AirLoopNum ! does this need to be optional?

          ! SUBROUTINE PARAMETER DEFINITIONS:
  CHARACTER(len=*), PARAMETER ::  RoutineName='SizeUnitarySystem'
  REAL(r64), PARAMETER ::    MaxRatedVolFlowPerRatedTotCap1 = 0.00006041d0 ! m3/s per watt = 450 cfm/ton
  REAL(r64), PARAMETER ::    MinRatedVolFlowPerRatedTotCap1 = 0.00004027d0 ! m3/s per watt = 300 cfm/ton

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: ThisCtrlZoneNum    ! the controlled zone number of the control zone !!!
  INTEGER   :: Iter               ! iteration count
  REAL(r64) :: MulSpeedFlowScale  ! variable speed air flow scaling factor
  INTEGER   :: MSHPIndex          ! Index to design Specification object
  INTEGER   :: BranchNum          ! Index to branch on air loop
  INTEGER   :: CompNum            ! Index to component on branch
  REAL(r64) :: BranchFlow         ! branch flow rate [m3/s]
  REAL(r64) :: BranchFanFlow      ! branch fan flow rate [m3/s]
  LOGICAL   :: ErrFound           ! logical error flag
  CHARACTER(len=MaxNameLength) :: FanType  ! fan type
  CHARACTER(len=MaxNameLength) :: FanName  ! fan name
  INTEGER   :: DXHeatCoilBranch   ! branch where DX heating coil is located
  INTEGER   :: DXHeatCoilCompNum  ! comp number of DX heating coil on branch
  INTEGER   :: CoolUnitarySystemNum ! index to unitary system with DX cooling coil
  INTEGER   :: CoolCoilIndex      ! index to DX cooling coil
  INTEGER   :: CoolCoilType       ! type of DX cooling coil
  CHARACTER(len=MaxNameLength) :: CoolCoilName ! name of DX cooling coil
  REAL(r64) :: rhoair             ! air density [kg/m3]
  REAL(r64) :: CpAirStd           ! air specific heat [J/kg-k]
  REAL(r64) :: MixTemp            ! mixed air temp used for sizing [C]
  REAL(r64) :: MixHumRat          ! mixed air humidity ratio used for sizing [kg/kg]
  REAL(r64) :: MixEnth            ! mixed air enthalpy used for sizing [J/kg]
  REAL(r64) :: MixWetBulb         ! mixed air wet bulb temp used for sizing [C]
  REAL(r64) :: SupTemp            ! supply air temp used for sizing [C]
  REAL(r64) :: SupHumRat          ! supply air humidity ratio used for sizing [kg/kg]
  REAL(r64) :: SupEnth            ! supply air enthalpy used for sizing [J/kg]
  REAL(r64) :: OutTemp            ! outdoor air temp used for sizing [C]
  REAL(r64) :: OutAirFrac         ! fraction of outdoor air flow
  REAL(r64) :: VolFlowRate        ! volumetric flow rate [m3/s]
  REAL(r64) :: CoolCapAtPeak      ! cooling capacity at peak [W]
  REAL(r64) :: HeatCapAtPeak      ! heating capacity at peak [W]
  INTEGER   :: TimeStepNumAtMax   ! time step at peak
  INTEGER   :: DDNum              ! design day index at peak
  REAL(r64) :: TotCapTempModFac   ! capacity modifier used for sizing
  REAL(r64) :: RatedVolFlowPerRatedTotCap !Rated Air Volume Flow Rate divided by Rated Total Capacity[m3/s-W)
  CHARACTER(len=MaxNameLength) :: SystemType ! type of air loop equipment
  REAL(r64) :: OnOffAirFlowRatio  ! used to pass to cooling coil for sizing
  REAL(r64) :: PartLoadRatio      ! used to pass to cooling coil for sizing
  INTEGER   :: CapFTCurve         ! index to DX coil Capacity as a function of Temperature curve
  LOGICAL   :: TempCoolingLoad    ! size cooling coils with a cooling load, save actual load
  LOGICAL   :: TempHeatingLoad    ! save actual load
  REAL(r64) :: SysCoolingFlow     ! individually sized cooling flow rate [m3/s]
  REAL(r64) :: SysHeatingFlow     ! individually sized heating flow rate [m3/s]
  CHARACTER(len=MaxNameLength) :: HXCoilName         ! cooling coil name in HXAssisted parent
  INTEGER :: ActualCoolCoilType ! cooling coil type in HXAssisted parent

  CALL ManageEMS(emsCallFromUnitarySystemSizing) ! calling point

  ThisCtrlZoneNum = 0
  DXCoolCap = 0.0d0
  UnitaryHeatCap = 0.0d0
  SuppHeatCap = 0.0d0
  TempCoolingLoad = CoolingLoad
  TempHeatingLoad = HeatingLoad
  CoolingLoad = .TRUE.
  HeatingLoad = .FALSE.
  ZoneCoolingOnlyFan = .FALSE.
  ZoneHeatingOnlyFan = .FALSE.
  SysCoolingFlow = 0.0d0
  SysHeatingFlow = 0.0d0
  CoolCapAtPeak = 0.0d0
  HeatCapAtPeak = 0.0d0

!  IF(UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
!    IF(
!    UnitarySystem(UnitarySysNum)%DesignCoolingCapacity =    &
!     GetWaterHXAssistedCoilCapacity(CoolingCoilType,CoolingCoilName,ErrFlag)
!    IF(UnitarySystem(UnitarySysNum)%DesignCoolingCapacity == Autosize) &
!        UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
!    IF (ErrFlag) THEN
!      CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
!      ErrorsFound=.TRUE.
!    END IF
!  END IF

  IF ((CurOASysNum > 0 .OR. CurSysNum > 0) .AND. UnitarySystem(UnitarySysNum)%RequestAutosize) THEN
    CALL CheckSysSizing(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name)
  ELSE IF(CurZoneEqNum > 0)THEN
    CALL CheckZoneSizing(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name)
  END IF

  IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow /= AutoSize) &
    SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
  IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow /= AutoSize) &
    SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow

  IF(UnitarySystem(UnitarySysNum)%RequestAutosize)THEN
  IF (CurOASysNum > 0) THEN
!    CALL CheckSysSizing(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name)
    IF(UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. .NOT. UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
      SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingSAFMethod)
        CASE (SupplyAirFlowRate, None)
          IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
            SysCoolingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          ELSE
            SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
          END IF
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%AirVolFlow = SysCoolingFlow
        CASE (FlowPerFloorArea)
          SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%AirVolFlow = SysCoolingFlow
        CASE (FractionOfAutosizedCoolingValue)
          SysCoolingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow * &
                           UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%AirVolFlow = SysCoolingFlow
        CASE (FlowPerCoolingCapacity)
          VolFlowRate = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          MixTemp = FinalSysSizing(CurSysNum)%CoolOutTemp
          MixHumRat = FinalSysSizing(CurSysNum)%CoolOutHumRat
          SupTemp = FinalSysSizing(CurSysNum)%PrecoolTemp
          SupHumRat = FinalSysSizing(CurSysNum)%PrecoolHumRat
          OutTemp = FinalSysSizing(CurSysNum)%CoolOutTemp
          rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
          MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
          MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
          SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
          IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingSingleSpeed .OR. &
             UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling .OR. &
             UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoSpeed .OR. &
             UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoStageWHumControl)THEN
              CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrFound)
            TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
          ELSE
            TotCapTempModFac = 1.0d0
          END IF
          CoolCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (MixEnth-SupEnth)))
          IF(TotCapTempModFac .GT. 0.d0)THEN
            CoolCapAtPeak = CoolCapAtPeak / TotCapTempModFac
          END IF
          SysCoolingFlow = CoolCapAtPeak * UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%AirVolFlow = SysCoolingFlow
          OASysEqSizing(CurOASysNum)%Capacity = .TRUE.
          OASysEqSizing(CurOASysNum)%DesCoolingLoad = CoolCapAtPeak
        CASE DEFAULT
          IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
            SysCoolingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          ELSE
            SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
          END IF
      END SELECT
    ELSE IF(UnitarySystem(UnitarySysNum)%HeatCoilExists .AND. .NOT. UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
      SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingSAFMethod)
        CASE (SupplyAirFlowRate, None)
          IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
            SysHeatingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          ELSE
            SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
          END IF
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%AirVolFlow = SysHeatingFlow
        CASE (FlowPerFloorArea)
          SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%AirVolFlow = SysHeatingFlow
        CASE (FractionOfAutosizedCoolingValue)
          SysHeatingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow * &
                           UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%AirVolFlow = SysHeatingFlow
        CASE (FlowPerHeatingCapacity)
          VolFlowRate = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          MixTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
          MixHumRat = FinalSysSizing(CurSysNum)%HeatOutHumRat
          SupTemp = FinalSysSizing(CurSysNum)%PrecoolTemp
          SupHumRat = FinalSysSizing(CurSysNum)%PrecoolHumRat
          OutTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
          rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
          MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
          MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
          SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
          IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
             UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
              CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFound)
            TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
          ELSE
            TotCapTempModFac = 1.0d0
          END IF
          HeatCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (SupEnth-MixEnth)))
          IF(TotCapTempModFac .GT. 0.d0)THEN
            HeatCapAtPeak = HeatCapAtPeak / TotCapTempModFac
          END IF
          SysHeatingFlow = HeatCapAtPeak * UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%AirVolFlow = SysCoolingFlow
          OASysEqSizing(CurOASysNum)%Capacity = .TRUE.
          OASysEqSizing(CurOASysNum)%DesCoolingLoad = HeatCapAtPeak
        CASE DEFAULT
          IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
            SysHeatingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          ELSE
            SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
          END IF
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%AirVolFlow = SysCoolingFlow
      END SELECT
    ELSE ! Cooling and Heating coil are present
      SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingSAFMethod)
        CASE (SupplyAirFlowRate, None)
          IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
            SysCoolingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          ELSE
            SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
          END IF
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
        CASE (FlowPerFloorArea)
          SysCoolingFlow = MAX(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow, &
                               UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow)
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
        CASE (FractionOfAutosizedCoolingValue)
          SysCoolingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow * &
              MAX(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow, UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow)
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = SysCoolingFlow
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
        CASE (FlowPerCoolingCapacity)
          VolFlowRate = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          MixTemp = FinalSysSizing(CurSysNum)%CoolOutTemp
          MixHumRat = FinalSysSizing(CurSysNum)%CoolOutHumRat
          SupTemp = FinalSysSizing(CurSysNum)%PrecoolTemp
          SupHumRat = FinalSysSizing(CurSysNum)%PrecoolHumRat
          OutTemp = FinalSysSizing(CurSysNum)%CoolOutTemp
          rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
          MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
          MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
          SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
          IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingSingleSpeed .OR. &
             UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling .OR. &
             UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoSpeed .OR. &
             UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoStageWHumControl)THEN
              CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrFound)
            TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
          ELSE
            TotCapTempModFac = 1.0d0
          END IF
          CoolCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (MixEnth-SupEnth)))
          IF(TotCapTempModFac .GT. 0.d0)THEN
            CoolCapAtPeak = CoolCapAtPeak / TotCapTempModFac
          END IF
          SysCoolingFlow = CoolCapAtPeak * UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%Capacity = .TRUE.
        CASE DEFAULT
          IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
            SysCoolingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          ELSE
            SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
          END IF
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
      END SELECT
      SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingSAFMethod)
        CASE (SupplyAirFlowRate, None)
          IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
            SysHeatingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          ELSE
            SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
          END IF
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
        CASE (FlowPerFloorArea)
          SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
        CASE (FractionOfAutosizedCoolingValue)
          SysHeatingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow * &
              UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = SysHeatingFlow
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
        CASE (FlowPerHeatingCapacity)
          VolFlowRate = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          MixTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
          MixHumRat = FinalSysSizing(CurSysNum)%HeatOutHumRat
          SupTemp = FinalSysSizing(CurSysNum)%PrecoolTemp
          SupHumRat = FinalSysSizing(CurSysNum)%PrecoolHumRat
          OutTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
          rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
          MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
          MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
          SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
          IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
             UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
              CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFound)
            TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
          ELSE
            TotCapTempModFac = 1.0d0
          END IF
          HeatCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (SupEnth-MixEnth)))
          IF(TotCapTempModFac .GT. 0.d0)THEN
            HeatCapAtPeak = HeatCapAtPeak / TotCapTempModFac
          END IF
          SysHeatingFlow = HeatCapAtPeak * UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
          OASysEqSizing(CurOASysNum)%Capacity = .TRUE.
        CASE DEFAULT
          IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
            SysHeatingFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          ELSE
            SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
          END IF
          OASysEqSizing(CurOASysNum)%AirFlow = .TRUE.
      END SELECT
      OASysEqSizing(CurOASysNum)%AirVolFlow = MAX(SysCoolingFlow,SysHeatingFlow)
      OASysEqSizing(CurOASysNum)%DesHeatingLoad = MAX(CoolCapAtPeak,HeatCapAtPeak)
    END IF
  ELSE

    IF (CurSysNum > 0) THEN

!      CALL CheckSysSizing(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name)

      IF(UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. .NOT. UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
        SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingSAFMethod)
          CASE (SupplyAirFlowRate, None)
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
              SysCoolingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
            ELSE
              SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            END IF
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysCoolingFlow
          CASE (FlowPerFloorArea)
            SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysCoolingFlow
          CASE (FractionOfAutosizedCoolingValue)
            SysCoolingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow * &
                             UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysCoolingFlow
          CASE (FlowPerCoolingCapacity)
            VolFlowRate = FinalSysSizing(CurSysNum)%DesMainVolFlow
            SupTemp = FinalSysSizing(CurSysNum)%CoolSupTemp
            SupHumRat = FinalSysSizing(CurSysNum)%CoolSupHumRat
            IF (PrimaryAirSystem(CurSysNum)%NumOACoolCoils == 0) THEN ! there is no precooling of the OA stream
              MixTemp = FinalSysSizing(CurSysNum)%CoolMixTemp
              MixHumRat = FinalSysSizing(CurSysNum)%CoolMixHumRat
            ELSE ! there is precooling of OA stream
              IF (VolFlowRate > 0.0d0) THEN
                OutAirFrac = FinalSysSizing(CurSysNum)%DesOutAirVolFlow / VolFlowRate
              ELSE
                OutAirFrac = 1.0d0
              END IF
              OutAirFrac = MIN(1.0d0,MAX(0.0d0,OutAirFrac))
              MixTemp = OutAirFrac*FinalSysSizing(CurSysNum)%PrecoolTemp + &
                          (1.0d0-OutAirFrac)*FinalSysSizing(CurSysNum)%CoolRetTemp
              MixHumRat = OutAirFrac*FinalSysSizing(CurSysNum)%PrecoolHumRat + &
                            (1.0d0-OutAirFrac)*FinalSysSizing(CurSysNum)%CoolRetHumRat
            END IF
            OutTemp = FinalSysSizing(CurSysNum)%CoolOutTemp
            rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
            MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
            MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
            SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
            IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingSingleSpeed .OR. &
               UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling .OR. &
               UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoSpeed .OR. &
               UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoStageWHumControl)THEN
                CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrFound)
              TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
            ELSE
              TotCapTempModFac = 1.0d0
            END IF
            CoolCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (MixEnth-SupEnth)))
            IF(TotCapTempModFac .GT. 0.d0)THEN
              CoolCapAtPeak = CoolCapAtPeak / TotCapTempModFac
            END IF
            SysCoolingFlow = CoolCapAtPeak * UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysCoolingFlow
            UnitarySysEqSizing(CurSysNum)%Capacity = .TRUE.
            UnitarySysEqSizing(CurSysNum)%DesCoolingLoad = CoolCapAtPeak
          CASE DEFAULT
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
              SysCoolingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
            ELSE
              SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            END IF
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysCoolingFlow
        END SELECT
      ELSE IF(UnitarySystem(UnitarySysNum)%HeatCoilExists .AND. .NOT. UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
        SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingSAFMethod)
          CASE (SupplyAirFlowRate)
            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
              SysHeatingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
            ELSE
              SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            END IF
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysHeatingFlow
          CASE (FlowPerFloorArea)
            SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysHeatingFlow
          CASE (FractionOfAutosizedCoolingValue)
            SysHeatingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow * &
                             UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysHeatingFlow
          CASE (FlowPerHeatingCapacity)
            VolFlowRate = FinalSysSizing(CurSysNum)%DesMainVolFlow
            SupTemp = FinalSysSizing(CurSysNum)%HeatSupTemp
            SupHumRat = FinalSysSizing(CurSysNum)%HeatSupHumRat
            IF (PrimaryAirSystem(CurSysNum)%NumOACoolCoils == 0) THEN ! there is no precooling of the OA stream
              MixTemp = FinalSysSizing(CurSysNum)%HeatMixTemp
              MixHumRat = FinalSysSizing(CurSysNum)%HeatMixHumRat
            ELSE ! there is precooling of OA stream
              IF (VolFlowRate > 0.0d0) THEN
                OutAirFrac = FinalSysSizing(CurSysNum)%DesOutAirVolFlow / VolFlowRate
              ELSE
                OutAirFrac = 1.0d0
              END IF
              OutAirFrac = MIN(1.0d0,MAX(0.0d0,OutAirFrac))
              MixTemp = OutAirFrac*FinalSysSizing(CurSysNum)%PrecoolTemp + &
                          (1.0d0-OutAirFrac)*FinalSysSizing(CurSysNum)%HeatRetTemp
              MixHumRat = OutAirFrac*FinalSysSizing(CurSysNum)%PrecoolHumRat + &
                            (1.0d0-OutAirFrac)*FinalSysSizing(CurSysNum)%HeatRetHumRat
            END IF
            OutTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
            rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
            MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
            MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
            SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
            IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
                CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFound)
              TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
            ELSE
              TotCapTempModFac = 1.0d0
            END IF
            HeatCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (SupEnth-MixEnth)))
            IF(TotCapTempModFac .GT. 0.d0)THEN
              HeatCapAtPeak = HeatCapAtPeak / TotCapTempModFac
            END IF
            SysHeatingFlow = HeatCapAtPeak * UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysHeatingFlow
            UnitarySysEqSizing(CurSysNum)%Capacity = .TRUE.
            UnitarySysEqSizing(CurSysNum)%DesHeatingLoad = HeatCapAtPeak
          CASE DEFAULT
            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
              SysHeatingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
            ELSE
              SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            END IF
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysHeatingFlow
        END SELECT
      ELSE ! Cooling and Heating coil are present
        SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingSAFMethod)
          CASE (SupplyAirFlowRate, None)
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
              SysCoolingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
            ELSE
              SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            END IF
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
          CASE (FlowPerFloorArea)
            SysCoolingFlow = MAX(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow, &
                                 UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow)
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
          CASE (FractionOfAutosizedCoolingValue)
            SysCoolingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow * &
                MAX(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow, UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow)
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
          CASE (FlowPerCoolingCapacity)
            VolFlowRate = FinalSysSizing(CurSysNum)%DesMainVolFlow
            SupTemp = FinalSysSizing(CurSysNum)%CoolSupTemp
            SupHumRat = FinalSysSizing(CurSysNum)%CoolSupHumRat
            IF (PrimaryAirSystem(CurSysNum)%NumOACoolCoils == 0) THEN ! there is no precooling of the OA stream
              MixTemp = FinalSysSizing(CurSysNum)%CoolMixTemp
              MixHumRat = FinalSysSizing(CurSysNum)%CoolMixHumRat
            ELSE ! there is precooling of OA stream
              IF (VolFlowRate > 0.0d0) THEN
                OutAirFrac = FinalSysSizing(CurSysNum)%DesMainVolFlow / VolFlowRate
              ELSE
                OutAirFrac = 1.0d0
              END IF
              OutAirFrac = MIN(1.0d0,MAX(0.0d0,OutAirFrac))
              MixTemp = OutAirFrac*FinalSysSizing(CurSysNum)%PrecoolTemp + &
                          (1.0d0-OutAirFrac)*FinalSysSizing(CurSysNum)%CoolRetTemp
              MixHumRat = OutAirFrac*FinalSysSizing(CurSysNum)%PrecoolHumRat + &
                            (1.0d0-OutAirFrac)*FinalSysSizing(CurSysNum)%CoolRetHumRat
            END IF
            OutTemp = FinalSysSizing(CurSysNum)%CoolOutTemp
            rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
            MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
            MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
            SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
            IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingSingleSpeed .OR. &
               UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling .OR. &
               UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoSpeed .OR. &
               UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoStageWHumControl)THEN
              CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrFound)
              TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
            ELSE
              TotCapTempModFac = 1.0d0
            END IF
            CoolCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (MixEnth-SupEnth)))
            IF(TotCapTempModFac .GT. 0.d0)THEN
              CoolCapAtPeak = CoolCapAtPeak / TotCapTempModFac
            END IF
            SysCoolingFlow = CoolCapAtPeak * UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%Capacity = .TRUE.
          CASE DEFAULT
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
              SysCoolingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
            ELSE
              SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            END IF
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
        END SELECT
        SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingSAFMethod)
          CASE (SupplyAirFlowRate)
            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
              SysHeatingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
            ELSE
              SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            END IF
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
          CASE (FlowPerFloorArea)
            SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
          CASE (FractionOfAutosizedCoolingValue)
            SysHeatingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow * &
                             UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
          CASE (FlowPerHeatingCapacity)
            VolFlowRate = FinalSysSizing(CurSysNum)%DesMainVolFlow
            SupTemp = FinalSysSizing(CurSysNum)%HeatSupTemp
            SupHumRat = FinalSysSizing(CurSysNum)%HeatSupHumRat
            IF (PrimaryAirSystem(CurSysNum)%NumOACoolCoils == 0) THEN ! there is no precooling of the OA stream
              MixTemp = FinalSysSizing(CurSysNum)%HeatMixTemp
              MixHumRat = FinalSysSizing(CurSysNum)%HeatMixHumRat
            ELSE ! there is precooling of OA stream
              IF (VolFlowRate > 0.0d0) THEN
                OutAirFrac = FinalSysSizing(CurSysNum)%DesMainVolFlow / VolFlowRate
              ELSE
                OutAirFrac = 1.0d0
              END IF
              OutAirFrac = MIN(1.0d0,MAX(0.0d0,OutAirFrac))
              MixTemp = OutAirFrac*FinalSysSizing(CurSysNum)%PrecoolTemp + &
                          (1.0d0-OutAirFrac)*FinalSysSizing(CurSysNum)%HeatRetTemp
              MixHumRat = OutAirFrac*FinalSysSizing(CurSysNum)%PrecoolHumRat + &
                            (1.0d0-OutAirFrac)*FinalSysSizing(CurSysNum)%HeatRetHumRat
            END IF
            OutTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
            rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
            MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
            MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
            SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
            IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
              CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFound)
              TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
            ELSE
              TotCapTempModFac = 1.0d0
            END IF
            HeatCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (SupEnth-MixEnth)))
            IF(TotCapTempModFac .GT. 0.d0)THEN
              HeatCapAtPeak = HeatCapAtPeak / TotCapTempModFac
            END IF
            SysHeatingFlow = HeatCapAtPeak * UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
            UnitarySysEqSizing(CurSysNum)%Capacity = .TRUE.
          CASE DEFAULT
            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
              SysHeatingFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
            ELSE
              SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            END IF
            UnitarySysEqSizing(CurSysNum)%AirFlow = .TRUE.
        END SELECT
        UnitarySysEqSizing(CurSysNum)%AirVolFlow = MAX(SysCoolingFlow,SysHeatingFlow)
        UnitarySysEqSizing(CurSysNum)%DesCoolingLoad = MAX(CoolCapAtPeak,HeatCapAtPeak)
      END IF
    ELSEIF (CurZoneEqNum > 0) THEN
      ! if we keep this (zone equipment) then we should probably check to see IF a cooling/heating coil is present
      ! and use just cooling if only a cooling coil, or just heating if only a heating coil
!      CALL CheckZoneSizing(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name)

       IF(UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. .NOT. UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
         ZoneCoolingOnlyFan = .TRUE.
         SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingSAFMethod)
           CASE (SupplyAirFlowRate)
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
              SysCoolingFlow = FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
            ELSE
              SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            END IF
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysCoolingFlow
           CASE (FlowPerFloorArea)
             SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
             UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
             ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
             ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysCoolingFlow
           CASE (FractionOfAutosizedCoolingValue)
             SysCoolingFlow = FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow * &
                              UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
             UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
             ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
             ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysCoolingFlow
           CASE (FlowPerCoolingCapacity)
             VolFlowRate = FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
             IF(ZoneEqDXCoil)THEN
               IF (ZoneEqSizing(CurZoneEqNum)%OAVolFlow > 0.0d0) THEN
                 MixTemp = FinalZoneSizing(CurZoneEqNum)%DesCoolCoilInTemp
                 MixHumRat = FinalZoneSizing(CurZoneEqNum)%DesCoolCoilInHumRat
               ELSE
                 MixTemp = FinalZoneSizing(CurZoneEqNum)%ZoneRetTempAtCoolPeak
                 MixHumRat = FinalZoneSizing(CurZoneEqNum)%ZoneHumRatAtCoolPeak
               END IF
             ELSE
               MixTemp = FinalZoneSizing(CurZoneEqNum)%DesCoolCoilInTemp
               MixHumRat = FinalZoneSizing(CurZoneEqNum)%DesCoolCoilInHumRat
             END IF
             SupTemp = FinalZoneSizing(CurZoneEqNum)%CoolDesTemp
             SupHumRat = FinalZoneSizing(CurZoneEqNum)%CoolDesHumRat
             TimeStepNumAtMax = FinalZoneSizing(CurZoneEqNum)%TimeStepNumAtCoolMax
             DDNum = FinalZoneSizing(CurZoneEqNum)%CoolDDNum
             IF (DDNum > 0 .and. TimeStepNumAtMax > 0) THEN
               OutTemp = DesDayWeath(DDNum)%Temp(TimeStepNumAtMax)
             ELSE
               OutTemp = 0.0d0
             END IF
             rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
             MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
             MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
             SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
             IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingSingleSpeed .OR. &
                UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling .OR. &
                UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoSpeed .OR. &
                UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoStageWHumControl)THEN
               CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrFound)
               TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
             ELSE
               TotCapTempModFac = 1.0d0
             END IF
             CoolCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (MixEnth-SupEnth)))
             IF(TotCapTempModFac .GT. 0.d0)THEN
               CoolCapAtPeak = CoolCapAtPeak / TotCapTempModFac
             END IF
             SysCoolingFlow = CoolCapAtPeak * UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
             UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
             ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
             ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysCoolingFlow
             ZoneEqSizing(CurZoneEqNum)%Capacity = .TRUE.
             ZoneEqSizing(CurZoneEqNum)%DesCoolingLoad = CoolCapAtPeak
           CASE DEFAULT
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
              SysCoolingFlow = FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
            ELSE
              SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            END IF
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysCoolingFlow
         END SELECT
       ELSE IF(UnitarySystem(UnitarySysNum)%HeatCoilExists .AND. .NOT. UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
         ZoneHeatingOnlyFan = .TRUE.
        SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingSAFMethod)
          CASE (SupplyAirFlowRate)
            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
              SysHeatingFlow = FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow
            ELSE
              SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            END IF
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysHeatingFlow
          CASE (FlowPerFloorArea)
            SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysHeatingFlow
          CASE (FractionOfAutosizedCoolingValue)
            SysHeatingFlow = FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow * &
                             UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysHeatingFlow
          CASE (FlowPerHeatingCapacity)
            VolFlowRate = FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow
            IF(ZoneEqDXCoil)THEN
              IF (ZoneEqSizing(CurZoneEqNum)%OAVolFlow > 0.0d0) THEN
                MixTemp = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInTemp
                MixHumRat = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInHumRat
              ELSE
                MixTemp = FinalZoneSizing(CurZoneEqNum)%ZoneRetTempAtHeatPeak
                MixHumRat = FinalZoneSizing(CurZoneEqNum)%ZoneHumRatAtHeatPeak
              END IF
            ELSE
              MixTemp = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInTemp
              MixHumRat = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInHumRat
            END IF
            SupTemp = FinalZoneSizing(CurZoneEqNum)%HeatDesTemp
            SupHumRat = FinalZoneSizing(CurZoneEqNum)%HeatDesHumRat
            TimeStepNumAtMax = FinalZoneSizing(CurZoneEqNum)%TimeStepNumAtHeatMax
            DDNum = FinalZoneSizing(CurZoneEqNum)%HeatDDNum
            IF (DDNum > 0 .and. TimeStepNumAtMax > 0) THEN
              OutTemp = DesDayWeath(DDNum)%Temp(TimeStepNumAtMax)
            ELSE
              OutTemp = 0.0d0
            END IF
            rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
            MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
            MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
            SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
            IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
              CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFound)
              TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
            ELSE
              TotCapTempModFac = 1.0d0
            END IF
            HeatCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (SupEnth-MixEnth)))
            IF(TotCapTempModFac .GT. 0.d0)THEN
              HeatCapAtPeak = HeatCapAtPeak / TotCapTempModFac
            END IF
            SysHeatingFlow = HeatCapAtPeak * UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysHeatingFlow
            ZoneEqSizing(CurZoneEqNum)%Capacity = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%DesHeatingLoad = HeatCapAtPeak
          CASE DEFAULT
            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
              SysHeatingFlow = FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow
            ELSE
              SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            END IF
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysHeatingFlow
        END SELECT
      ELSE
        SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingSAFMethod)
          CASE (SupplyAirFlowRate, None)
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
              SysCoolingFlow = FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
            ELSE
              SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            END IF
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
          CASE (FlowPerFloorArea)
            SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize ! allow reporting for sizing
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
          CASE (FractionOfAutosizedCoolingValue)
            SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow * FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
          CASE (FlowPerCoolingCapacity)
            VolFlowRate = FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
            IF(ZoneEqDXCoil)THEN
              IF (ZoneEqSizing(CurZoneEqNum)%OAVolFlow > 0.0d0) THEN
                MixTemp = FinalZoneSizing(CurZoneEqNum)%DesCoolCoilInTemp
                MixHumRat = FinalZoneSizing(CurZoneEqNum)%DesCoolCoilInHumRat
              ELSE
                MixTemp = FinalZoneSizing(CurZoneEqNum)%ZoneRetTempAtCoolPeak
                MixHumRat = FinalZoneSizing(CurZoneEqNum)%ZoneHumRatAtCoolPeak
              END IF
            ELSE
              MixTemp = FinalZoneSizing(CurZoneEqNum)%DesCoolCoilInTemp
              MixHumRat = FinalZoneSizing(CurZoneEqNum)%DesCoolCoilInHumRat
            END IF
            SupTemp = FinalZoneSizing(CurZoneEqNum)%CoolDesTemp
            SupHumRat = FinalZoneSizing(CurZoneEqNum)%CoolDesHumRat
            TimeStepNumAtMax = FinalZoneSizing(CurZoneEqNum)%TimeStepNumAtCoolMax
            DDNum = FinalZoneSizing(CurZoneEqNum)%CoolDDNum
            IF (DDNum > 0 .and. TimeStepNumAtMax > 0) THEN
              OutTemp = DesDayWeath(DDNum)%Temp(TimeStepNumAtMax)
            ELSE
              OutTemp = 0.0d0
            END IF
            rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
            MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
            MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
            SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
            IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingSingleSpeed .OR. &
               UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling .OR. &
               UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoSpeed .OR. &
               UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoStageWHumControl)THEN
              CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrFound)
              TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
            ELSE
              TotCapTempModFac = 1.0d0
            END IF
            CoolCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (MixEnth-SupEnth)))
            IF(TotCapTempModFac .GT. 0.d0)THEN
              CoolCapAtPeak = CoolCapAtPeak / TotCapTempModFac
            END IF
            SysCoolingFlow = CoolCapAtPeak * UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Autosize
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%Capacity = .TRUE.
          CASE DEFAULT
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize)THEN
              SysCoolingFlow = FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
            ELSE
              SysCoolingFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
            END IF
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
        END SELECT
        SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingSAFMethod)
          CASE (SupplyAirFlowRate)
            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
              SysHeatingFlow = FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow
            ELSE
              SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            END IF
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
          CASE (FlowPerFloorArea)
            SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
          CASE (FractionOfAutosizedCoolingValue)
            SysHeatingFlow = FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow * &
                             UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
          CASE (FlowPerHeatingCapacity)
            VolFlowRate = FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow
            IF(ZoneEqDXCoil)THEN
              IF (ZoneEqSizing(CurZoneEqNum)%OAVolFlow > 0.0d0) THEN
                MixTemp = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInTemp
                MixHumRat = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInHumRat
              ELSE
                MixTemp = FinalZoneSizing(CurZoneEqNum)%ZoneRetTempAtHeatPeak
                MixHumRat = FinalZoneSizing(CurZoneEqNum)%ZoneHumRatAtHeatPeak
              END IF
            ELSE
              MixTemp = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInTemp
              MixHumRat = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInHumRat
            END IF
            SupTemp = FinalZoneSizing(CurZoneEqNum)%HeatDesTemp
            SupHumRat = FinalZoneSizing(CurZoneEqNum)%HeatDesHumRat
            TimeStepNumAtMax = FinalZoneSizing(CurZoneEqNum)%TimeStepNumAtHeatMax
            DDNum = FinalZoneSizing(CurZoneEqNum)%HeatDDNum
            IF (DDNum > 0 .and. TimeStepNumAtMax > 0) THEN
              OutTemp = DesDayWeath(DDNum)%Temp(TimeStepNumAtMax)
            ELSE
              OutTemp = 0.0d0
            END IF
            rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
            MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
            MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
            SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
            IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
              CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFound)
              TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
            ELSE
              TotCapTempModFac = 1.0d0
            END IF
            HeatCapAtPeak = MAX(0.d0, (rhoair * VolFlowRate * (SupEnth-MixEnth)))
            IF(TotCapTempModFac .GT. 0.d0)THEN
              HeatCapAtPeak = HeatCapAtPeak / TotCapTempModFac
            END IF
            SysHeatingFlow = HeatCapAtPeak * UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%Capacity = .TRUE.
          CASE DEFAULT
            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
              SysHeatingFlow = FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow
            ELSE
              SysHeatingFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            END IF
            ZoneEqSizing(CurZoneEqNum)%AirFlow = .TRUE.
        END SELECT
        ZoneEqSizing(CurZoneEqNum)%AirVolFlow = MAX(SysCoolingFlow,SysHeatingFlow)
        ZoneEqSizing(CurZoneEqNum)%DesCoolingLoad = MAX(CoolCapAtPeak,HeatCapAtPeak)
      END IF
    END IF
  END IF
  END IF ! IF(UnitarySystem(UnitarySysNum)%RequestAutosize)THEN

! Not sure yet how to enforce heat pump cooling/heating air flow and capacity limits.
! Other checks are in place (e.g., DXCoolCap) to already account for heat pump DX coils but apply to all coil types.
! This method would actually size the HP to the larger of cooling or heating but not yet ready to implement.
!  IF(UnitarySystem(UnitarySysNum)%HeatPump .AND. UnitarySystem(UnitarySysNum)%RequestAutosize)THEN
!    IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize .AND. &
!       UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize)THEN
!      IF(CurOASysNum > 0)THEN
!        IF(OASysEqSizing(CurOASysNum)%AirFlow .AND. .NOT. OASysEqSizing(CurOASysNum)%Capacity)THEN
!          SysCoolingFlow = MAX(SysCoolingFlow,SysHeatingFlow)
!          SysHeatingFlow = SysCoolingFlow
!          OASysEqSizing(CurOASysNum)%AirVolFlow = SysCoolingFlow
!        ELSE IF(OASysEqSizing(CurOASysNum)%Capacity)THEN
!          SysCoolingFlow = MAX(SysCoolingFlow,SysHeatingFlow)
!          SysHeatingFlow = SysCoolingFlow
!          OASysEqSizing(CurOASysNum)%AirVolFlow = SysCoolingFlow
!          CoolCapAtPeak = MAX(CoolCapAtPeak,HeatCapAtPeak)
!          HeatCapAtPeak = CoolCapAtPeak
!          OASysEqSizing(CurOASysNum)%DesCoolingLoad = CoolCapAtPeak
!          OASysEqSizing(CurOASysNum)%DesHeatingLoad = CoolCapAtPeak * UnitarySystem(UnitarySysNum)%HeatingSizingRatio
!        END IF
!      ELSE IF(CurSysNum > 0)THEN
!        IF(UnitarySysEqSizing(CurSysNum)%AirFlow .AND. .NOT. UnitarySysEqSizing(CurSysNum)%Capacity)THEN
!          SysCoolingFlow = MAX(SysCoolingFlow,SysHeatingFlow)
!          SysHeatingFlow = SysCoolingFlow
!          UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysCoolingFlow
!        ELSE IF(UnitarySysEqSizing(CurSysNum)%Capacity)THEN
!          SysCoolingFlow = MAX(SysCoolingFlow,SysHeatingFlow)
!          SysHeatingFlow = SysCoolingFlow
!          UnitarySysEqSizing(CurSysNum)%AirVolFlow = SysCoolingFlow
!          CoolCapAtPeak = MAX(CoolCapAtPeak,HeatCapAtPeak)
!          HeatCapAtPeak = CoolCapAtPeak
!          UnitarySysEqSizing(CurSysNum)%DesCoolingLoad = CoolCapAtPeak
!          UnitarySysEqSizing(CurSysNum)%DesHeatingLoad = CoolCapAtPeak * UnitarySystem(UnitarySysNum)%HeatingSizingRatio
!        END IF
!      ELSE IF(CurZoneEqNum > 0)THEN
!        IF(ZoneEqSizing(CurZoneEqNum)%AirFlow .AND. .NOT. ZoneEqSizing(CurZoneEqNum)%Capacity)THEN
!          SysCoolingFlow = MAX(SysCoolingFlow,SysHeatingFlow)
!          SysHeatingFlow = SysCoolingFlow
!          ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysCoolingFlow
!        ELSE IF(ZoneEqSizing(CurZoneEqNum)%Capacity)THEN
!          SysCoolingFlow = MAX(SysCoolingFlow,SysHeatingFlow)
!          SysHeatingFlow = SysCoolingFlow
!          ZoneEqSizing(CurZoneEqNum)%AirVolFlow = SysCoolingFlow
!          CoolCapAtPeak = MAX(CoolCapAtPeak,HeatCapAtPeak)
!          HeatCapAtPeak = CoolCapAtPeak
!          ZoneEqSizing(CurZoneEqNum)%DesCoolingLoad = CoolCapAtPeak
!          ZoneEqSizing(CurZoneEqNum)%DesHeatingLoad = CoolCapAtPeak * UnitarySystem(UnitarySysNum)%HeatingSizingRatio
!        END IF
!      END IF
!    END IF
!  END IF

  IF (UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate == AutoSize .AND. &
      UnitarySystem(UnitarySysNum)%FanExists) THEN

    UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = MAX(SysCoolingFlow,SysHeatingFlow)

    IF (UnitarySystem(UnitarySysNum)%DesignFanVolFlowRateEMSOverrideOn) THEN
      UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = UnitarySystem(UnitarySysNum)%DesignFanVolFlowRateEMSOverrideValue
    END IF

    IF(UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate < SmallAirVolFlow) THEN
      UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = 0.0d0
    END IF

    CALL ReportSizingOutput(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name, &
                            'Supply Air Flow Rate [m3/s]', &
                             UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate)

  END IF

  ! not sure what to do if UnitarySystem has only 1 coil type and flow needs to occur when present coil is off
  ! how does constant fan operating mode pertain here?
  IF(UnitarySystem(UnitarySysNum)%HeatCoilExists .AND. .NOT. UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
    UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = SysHeatingFlow
  ELSE IF(UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. .NOT. UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
    UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = SysCoolingFlow
  END IF

    IF (UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == AutoSize .AND. &
      UnitarySystem(UnitarySysNum)%HeatCoilExists) THEN

    IF (CurOASysNum > 0) THEN
      IF(OASysEqSizing(CurOASysNum)%AirFlow)THEN
        UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = OASysEqSizing(CurOASysNum)%AirVolFlow
      ELSE
        UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
      END IF
      IF (UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow < SmallAirVolFlow) THEN
        UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = 0.0d0
      END IF
    ELSE
      IF (CurSysNum > 0) THEN

        IF(UnitarySysEqSizing(CurSysNum)%AirFlow)THEN
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = UnitarySysEqSizing(CurSysNum)%AirVolFlow
        ELSE
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
        END IF
        IF (FinalSysSizing(CurSysNum)%DesMainVolFlow < SmallAirVolFlow) THEN
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = 0.0d0
        END IF

        IF (UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlowEMSOverrideOn) THEN
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlowEMSOverrideValue
        END IF

      ELSEIF (CurZoneEqNum > 0) THEN
        ! if we keep this (zone equipment) then we should probably check to see if a cooling/heating coil is present
        ! and use just cooling if only a cooling coil, or just heating if only a heating coil
        IF(ZoneEqSizing(CurZoneEqNum)%AirFlow)THEN
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = ZoneEqSizing(CurZoneEqNum)%AirVolFlow
        ELSE
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow =   &
                 MAX(FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow,FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow)
        END IF
        IF (UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow < SmallAirVolFlow) THEN
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = 0.0d0
        END IF

        IF (UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlowEMSOverrideOn) THEN
          UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlowEMSOverrideValue
        END IF

      END IF
    END IF

    CALL ReportSizingOutput(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name, &
                            'Supply Air Flow Rate During Heating Operation [m3/s]', &
                            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow)
  END IF

  IF (UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == AutoSize .AND. &
      UnitarySystem(UnitarySysNum)%CoolCoilExists) THEN

    IF (CurOASysNum > 0) THEN
      IF(OASysEqSizing(CurOASysNum)%AirFlow)THEN
        UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = OASysEqSizing(CurOASysNum)%AirVolFlow
      ELSE
        UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
      END IF
    ELSE
      IF (CurSysNum > 0) THEN

        IF(UnitarySysEqSizing(CurSysNum)%AirFlow)THEN
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = UnitarySysEqSizing(CurSysNum)%AirVolFlow
        ELSE
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
        END IF
        IF (UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow < SmallAirVolFlow) THEN
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = 0.0d0
        END IF

        IF (UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlowEMSOverrideOn) THEN
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlowEMSOverrideValue
        END IF

      ELSEIF (CurZoneEqNum > 0) THEN
        ! if we keep this (zone equipment) then we should probably check to see if a cooling/heating coil is present
        ! and use just cooling if only a cooling coil, or just heating if only a heating coil
        IF(ZoneEqSizing(CurZoneEqNum)%AirFlow)THEN
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = ZoneEqSizing(CurZoneEqNum)%AirVolFlow
        ELSE
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow =   &
                 MAX(FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow,FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow)
        END IF
        IF (UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow < SmallAirVolFlow) THEN
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = 0.0d0
        END IF

        IF (UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlowEMSOverrideOn) THEN
          UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlowEMSOverrideValue
        END IF

      END IF
    END IF

    CALL ReportSizingOutput(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name, &
                            'Supply Air Flow Rate During Cooling Operation [m3/s]', &
                             UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow)

  END IF

  IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow == AutoSize .AND. &
      (UnitarySystem(UnitarySysNum)%CoolCoilExists .OR. &
       (UnitarySystem(UnitarySysNum)%HeatCoilExists .OR. UnitarySystem(UnitarySysNum)%SuppCoilExists))) THEN

    IF (CurOASysNum > 0) THEN
      IF(OASysEqSizing(CurOASysNum)%AirFlow)THEN
        UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = OASysEqSizing(CurOASysNum)%AirVolFlow
      ELSE
        UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
      END IF
    ELSE
      IF (CurSysNum > 0) THEN

        IF(UnitarySysEqSizing(CurSysNum)%AirFlow)THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = UnitarySysEqSizing(CurSysNum)%AirVolFlow
        ELSE
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
        END IF
        IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow < SmallAirVolFlow) THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = 0.0d0
        END IF

        IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlowEMSOverrideOn) THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow=UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlowEMSOverrideValue
        END IF

        CALL ReportSizingOutput(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name, &
                               'Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s]', &
                                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow)

      ELSEIF (CurZoneEqNum > 0) THEN
        ! if we keep this (zone equipment) then we should probably check to see if a cooling/heating coil is present
        ! and use just cooling if only a cooling coil, or just heating if only a heating coil
!        CALL CheckZoneSizing(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name)
!  would use this to size cooling or heating only systems except for the case where dual UnitarySystems are on the branch
!  and each has only 1 cooling or heating coil ??? How to handle?
!  Use same logic for other flow rates in this sizing module.
        IF(UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow =   &
                 MAX(FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow,FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow)
        ELSE IF(UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow =   &
                 FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
        ELSE IF(UnitarySystem(UnitarySysNum)%HeatCoilExists .OR. UnitarySystem(UnitarySysNum)%SuppCoilExists)THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow =   &
                 FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow
        ELSE
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = 0.0d0 ! ?
        END IF

        IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow < SmallAirVolFlow) THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = 0.0d0
        END IF

        IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlowEMSOverrideOn) THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow=UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlowEMSOverrideValue
        END IF

        CALL ReportSizingOutput(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name, &
                               'Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s]', &
                                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow)

      END IF
    END IF
  ELSE IF (UnitarySystem(UnitarySysNum)%CoolCoilExists .OR. UnitarySystem(UnitarySysNum)%HeatCoilExists) THEN
    SELECT CASE(UnitarySystem(UnitarySysNum)%NoCoolHeatSAFMethod)
      CASE (SupplyAirFlowRate)
        IF(UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow == Autosize)THEN
          IF (CurOASysNum > 0) THEN
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
          ELSE IF (CurSysNum > 0) THEN
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = FinalSysSizing(CurSysNum)%DesMainVolFlow
          ELSE IF (CurZoneEqNum > 0) THEN
            IF(UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
              UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = &
                MAX(FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow, FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow)
            ELSE IF(UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
              UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
            ELSE IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
              UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow
            ELSE
              ! just guessing here what this should be
              UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = 0.0d0
            END IF
          END IF
        END IF
      CASE (FlowPerFloorArea)
        ! already calculated in GetInput
      CASE (FractionOfAutosizedCoolingValue, FractionOfAutosizedHeatingValue)
        IF (CurOASysNum > 0) THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = &
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow * FinalSysSizing(CurSysNum)%DesOutAirVolFlow
        ELSE IF (CurSysNum > 0) THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = &
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow * FinalSysSizing(CurSysNum)%DesMainVolFlow
        ELSE IF (CurZoneEqNum > 0) THEN
          IF(UnitarySystem(UnitarySysNum)%NoCoolHeatSAFMethod == FractionOfAutosizedCoolingValue)THEN
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = &
              UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow * FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
          ELSE
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = &
              UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow * FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow
          END IF
        END IF
      CASE (FlowPerCoolingCapacity) ! these aren't going to work if the user doesn't choose the same method for all cases
        IF(DXCoolCap .EQ. 0.0d0)THEN
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = &
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow * &
              ZoneEqSizing(CurZoneEqNum)%DesCoolingLoad
        ELSE
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = &
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow * DXCoolCap
        END IF
      CASE (FlowPerHeatingCapacity)
        UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = &
          UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow * &
            ZoneEqSizing(CurZoneEqNum)%DesHeatingLoad
      CASE (None)
        ! what does this mean?
      CASE DEFAULT
      ! wait for CR's
    END SELECT

  ELSE
    UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = 0.0d0
  END IF


  SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)
  CASE(CoilDX_CoolingSingleSpeed)
    CALL SimDXCoil(Blank,On,.TRUE.,0.0d0,UnitarySystem(UnitarySysNum)%CoolingCoilIndex, 1)
    DXCoolCap = GetCoilCapacityByIndexType(UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                           UnitarySystem(UnitarySysNum)%CoolingCoilType_Num,ErrFound)
  CASE(CoilDX_CoolingHXAssisted,CoilWater_CoolingHXAssisted)
    Node(UnitarySystem(UnitarySysNum)%CoolCoilInletNodeNum)%MassFlowRate = SysCoolingFlow
    IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilWater_CoolingHXAssisted)THEN
      HXCoilName = GetHXDXCoilName(cAllCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num), &
                                   UnitarySystem(UnitarySysNum)%CoolingCoilName,ErrFound)
      ActualCoolCoilType = GetCoilObjectTypeNum(cAllCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num), &
                           UnitarySystem(UnitarySysNum)%CoolingCoilName,ErrFound,.TRUE.)
      CALL SetCoilDesFlow(cAllCoilTypes(ActualCoolCoilType),HXCoilName,SysCoolingFlow,ErrFound)
    END IF
    CALL SimHXAssistedCoolingCoil(Blank,.TRUE.,On, &
                                  1.0d0, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, 1, &
                                  HXUnitEnable=.FALSE., OnOffAFR = 1.0d0, EconomizerFlag=.FALSE.)
    IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilWater_CoolingHXAssisted)THEN
      DXCoolCap = GetWaterCoilCapacity(MakeUPPERCase(cAllCoilTypes(ActualCoolCoilType)),HXCoilName,ErrFound)
    ELSE
      DXCoolCap = GetCoilCapacity(cAllCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num), &
                                UnitarySystem(UnitarySysNum)%CoolingCoilName,ErrFound)
    END IF
  CASE(Coil_CoolingWaterDetailed)
    CALL SetCoilDesFlow(cAllCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num), &
                        UnitarySystem(UnitarySysNum)%CoolingCoilName,SysCoolingFlow,ErrFound)
  CASE(Coil_CoolingWaterToAirHPSimple)
    CALL SimWatertoAirHPSimple(Blank, &
           UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
           UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand, UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand, &
           0,0.0d0, UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
           UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
           0,0.0d0,FirstHVACIteration)
    DXCoolCap = GetSimpleCoilCapacity(cAllCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num), &
                                      UnitarySystem(UnitarySysNum)%CoolingCoilName,ErrFound)
  CASE(Coil_CoolingWaterToAirHP)
    CALL SimWatertoAirHP(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
           UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow,UnitarySystem(UnitarySysNum)%FanOpMode,&
           FirstHVACIteration,0.0d0,&
           UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
           UnitarySystem(UnitarySysNum)%HPTimeConstant, &
           UnitarySystem(UnitarySysNum)%FanDelayTime, &
           UnitarySystem(UnitarySysNum)%InitHeatPump, &
           0.0d0,0.0d0,0, 0.0d0)
    DXCoolCap = GetWAHPCoilCapacity(cAllCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num), &
                                    UnitarySystem(UnitarySysNum)%CoolingCoilName,ErrFound)
  CASE(Coil_CoolingWaterToAirHPVSEquationFit, Coil_CoolingAirToAirVariableSpeed)

    IF (UnitarySystem(UnitarySysNum)%NumOfSpeedCooling .GT. 0)THEN
      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedCooling))

      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%CoolMassFlowRate)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%CoolMassFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedCooling))

      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(UnitarySystem(UnitarySysNum)%NumOfSpeedCooling))
    END IF

    CALL SimVariableSpeedCoils(Blank,UnitarySystem(UnitarySysNum)%CoolingCoilIndex,&
           0,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
           UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime,&
           0,0.0d0,0.0d0,1,0.0d0,0.0d0,0.0d0 )     !conduct the sizing operation in the VS WSHP
    UnitarySystem(UnitarySysNum)%NumOfSpeedCooling = VarSpeedCoil(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)%NumOfSpeeds
    DXCoolCap = GetCoilCapacityVariableSpeed(cAllCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num), &
                                      UnitarySystem(UnitarySysNum)%CoolingCoilName,ErrFound)
    MulSpeedFlowScale = VarSpeedCoil(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)%RatedAirVolFlowRate/ &
       VarSpeedCoil(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)%MSRatedAirVolFlowRate(  &
          VarSpeedCoil(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)%NormSpedLevel)
    DO Iter = 1,UnitarySystem(UnitarySysNum)%NumOfSpeedCooling
      UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(Iter) =   &
         VarSpeedCoil(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)%MSRatedAirVolFlowRate(Iter) * MulSpeedFlowScale
      UnitarySystem(UnitarySysNum)%CoolMassFlowRate(Iter) = UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(Iter)* StdRhoAir
! it seems the ratio should reference the actual flow rates, not the fan flow ???
      IF(UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate .GT. 0.0d0 .AND. UnitarySystem(UnitarySysNum)%FanExists)THEN
        UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(Iter) = UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(Iter)/ &
!             UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedCooling)
              UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate
      ELSE
        UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(Iter) = UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(Iter)/ &
             UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedCooling)
      END IF
    END DO

    UnitarySystem(UnitarySysNum)%IdleVolumeAirRate = UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(1)
    UnitarySystem(UnitarySysNum)%IdleMassFlowRate  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(1)
    UnitarySystem(UnitarySysNum)%IdleSpeedRatio    = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(1)

  CASE(CoilDX_MultiSpeedCooling)

    IF (UnitarySystem(UnitarySysNum)%NumOfSpeedCooling .GT. 0)THEN
      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedCooling))

      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%CoolMassFlowRate)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%CoolMassFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedCooling))

      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(UnitarySystem(UnitarySysNum)%NumOfSpeedCooling))
    END IF

    OnOffAirFlowRatio = 1.0d0
    PartLoadRatio = 1.0d0
    CALL SetOnOffMassFlowRate(UnitarySysNum, OnOffAirFlowRatio, PartLoadRatio)
    CALL SimDXCoilMultiSpeed(Blank,1.0d0,1.0d0,UnitarySystem(UnitarySysNum)%CoolingCoilIndex,0,0,0)
    DXCoolCap = GetCoilCapacityByIndexType(UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                           UnitarySystem(UnitarySysNum)%CoolingCoilType_Num,ErrFound)

    MSHPIndex = UnitarySystem(UnitarySysNum)%DesignSpecMSHPIndex

    IF(MSHPIndex .GT. 0)THEN
      DO Iter = DesignSpecMSHP(MSHPIndex)%NumOfSpeedCooling, 1 , -1 ! use reverse order since we divide by CoolVolumeFlowRate(max)
        IF(DesignSpecMSHP(MSHPIndex)%CoolingVolFlowRatio(Iter) == Autosize) &
             DesignSpecMSHP(MSHPIndex)%CoolingVolFlowRatio(Iter) = &
               REAL(Iter,r64)/REAL(DesignSpecMSHP(MSHPIndex)%NumOfSpeedCooling,r64)
        UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(Iter) =   UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow * &
                                                           DesignSpecMSHP(MSHPIndex)%CoolingVolFlowRatio(Iter)
        UnitarySystem(UnitarySysNum)%CoolMassFlowRate(Iter) = UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(Iter)* StdRhoAir
        UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(Iter) = UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(Iter)/ &
                              UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(DesignSpecMSHP(MSHPIndex)%NumOfSpeedCooling)

      END DO
      UnitarySystem(UnitarySysNum)%IdleVolumeAirRate = UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(1)
      UnitarySystem(UnitarySysNum)%IdleMassFlowRate = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(1)
      UnitarySystem(UnitarySysNum)%IdleSpeedRatio   = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(1)
    END IF

  CASE DEFAULT
  END SELECT


  IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
      UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingElectric_MultiStage .OR. &
      UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingGas_MultiStage) THEN

    IF (UnitarySystem(UnitarySysNum)%NumOfSpeedHeating .GT. 0)THEN
      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedHeating))

      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%HeatMassFlowRate)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%HeatMassFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedHeating))

      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(UnitarySystem(UnitarySysNum)%NumOfSpeedHeating))
    END IF

    MSHPIndex = UnitarySystem(UnitarySysNum)%DesignSpecMSHPIndex

    IF(MSHPIndex .GT. 0)THEN
      DO Iter = DesignSpecMSHP(MSHPIndex)%NumOfSpeedHeating, 1 , -1 ! use reverse order since we divide by HeatVolumeFlowRate(max)
        IF(DesignSpecMSHP(MSHPIndex)%HeatingVolFlowRatio(Iter) == Autosize) &
             DesignSpecMSHP(MSHPIndex)%HeatingVolFlowRatio(Iter) = &
                REAL(Iter,r64)/REAL(DesignSpecMSHP(MSHPIndex)%NumOfSpeedHeating,r64)
        UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(Iter) =   UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow * &
                                                                  DesignSpecMSHP(MSHPIndex)%HeatingVolFlowRatio(Iter)
        UnitarySystem(UnitarySysNum)%HeatMassFlowRate(Iter) = UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(Iter)* StdRhoAir
        UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(Iter) = UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(Iter)/ &
                                      UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(DesignSpecMSHP(MSHPIndex)%NumOfSpeedHeating)
      END DO
      UnitarySystem(UnitarySysNum)%IdleVolumeAirRate = UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(1)
      UnitarySystem(UnitarySysNum)%IdleMassFlowRate = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(1)
      UnitarySystem(UnitarySysNum)%IdleSpeedRatio   = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(1)
    END IF
  ELSEIF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
            UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed) THEN
    CALL SimVariableSpeedCoils(Blank,UnitarySystem(UnitarySysNum)%HeatingCoilIndex,&
           0,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
           UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime,&
           0,0.0d0,0.0d0,1,0.0d0,0.0d0,0.0d0 ) !conduct the sizing operation in the VS WSHP

    UnitarySystem(UnitarySysNum)%NumOfSpeedHeating = VarSpeedCoil(UnitarySystem(UnitarySysNum)%HeatingCoilIndex)%NumOfSpeeds

    IF (UnitarySystem(UnitarySysNum)%NumOfSpeedHeating .GT. 0)THEN
      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedHeating))

      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%HeatMassFlowRate)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%HeatMassFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedHeating))

      IF(.NOT. ALLOCATED(UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio)) &
        ALLOCATE(UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(UnitarySystem(UnitarySysNum)%NumOfSpeedHeating))
    END IF

    MulSpeedFlowScale = VarSpeedCoil(UnitarySystem(UnitarySysNum)%HeatingCoilIndex)%RatedAirVolFlowRate/ &
                        VarSpeedCoil(UnitarySystem(UnitarySysNum)%HeatingCoilIndex)%MSRatedAirVolFlowRate(  &
                           VarSpeedCoil(UnitarySystem(UnitarySysNum)%HeatingCoilIndex)%NormSpedLevel)
    DO Iter = 1,UnitarySystem(UnitarySysNum)%NumOfSpeedHeating
      UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(Iter) =   &
         VarSpeedCoil(UnitarySystem(UnitarySysNum)%HeatingCoilIndex)%MSRatedAirVolFlowRate(Iter) * MulSpeedFlowScale
      UnitarySystem(UnitarySysNum)%HeatMassFlowRate(Iter) = UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(Iter)* StdRhoAir
      IF(UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate .GT. 0.0d0 .AND. UnitarySystem(UnitarySysNum)%FanExists)THEN
        UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(Iter) = UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(Iter)/ &
          UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate
      ELSE
        UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(Iter) = UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(Iter)/ &
          UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(UnitarySystem(UnitarySysNum)%NumOfSpeedHeating)
      END IF

    END DO

    IF(UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
      IF(ALLOCATED(UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate))THEN
        UnitarySystem(UnitarySysNum)%IdleVolumeAirRate = &
          MIN(UnitarySystem(UnitarySysNum)%IdleVolumeAirRate,UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(1))
        UnitarySystem(UnitarySysNum)%IdleMassFlowRate  = &
          MIN(UnitarySystem(UnitarySysNum)%IdleMassFlowRate,UnitarySystem(UnitarySysNum)%HeatMassFlowRate(1))
        UnitarySystem(UnitarySysNum)%IdleSpeedRatio    = &
          MIN(UnitarySystem(UnitarySysNum)%IdleSpeedRatio,UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(1))
      ELSE
        UnitarySystem(UnitarySysNum)%IdleVolumeAirRate = UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(1)
        UnitarySystem(UnitarySysNum)%IdleMassFlowRate  = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(1)
        UnitarySystem(UnitarySysNum)%IdleSpeedRatio    = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(1)
      END IF
    ELSE
      UnitarySystem(UnitarySysNum)%IdleVolumeAirRate = UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(1)
      UnitarySystem(UnitarySysNum)%IdleMassFlowRate  = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(1)
      UnitarySystem(UnitarySysNum)%IdleSpeedRatio    = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(1)
    END IF
  END IF

  IF(UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow < 0.0d0)THEN
    IF ( .NOT. SysSizingRunDone) THEN
      BranchNum = GetAirBranchIndex('AirloopHVAC:UnitarySystem',UnitarySystem(UnitarySysNum)%Name)
      FanType = ' '
      FanName = ' '
      BranchFanFlow = 0.0d0
      IF(BranchNum .GT. 0.0d0)CALL GetBranchFanTypeName(BranchNum, FanType, FanName, ErrFound)
      IF(.NOT. ErrFound .AND. BranchNum .GT. 0)BranchFanFlow = GetFanDesignVolumeFlowRate(FanType,FanName,ErrFound)
      IF(BranchNum .GT. 0.0d0)BranchFlow = GetBranchFlow(BranchNum)
      IF(BranchFanFlow > 0.0d0)THEN
        UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = BranchFanFlow
      ELSEIF(BranchFlow > 0.0d0)THEN
        UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = BranchFlow
      ELSEIF(BranchFlow == Autosize)THEN
        ! what do I do?
      END IF
    END IF
  END IF

    !Change the Volume Flow Rates to Mass Flow Rates
    UnitarySystem(UnitarySysNum)%DesignMassFlowRate = UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate * StdRhoAir
    UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow * StdRhoAir
    UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow* StdRhoAir
    UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirMassFlow = UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow* StdRhoAir

    UnitarySystem(UnitarySysNum)%SenLoadLoss = 0.0d0
    IF (UnitarySystem(UnitarySysNum)%Humidistat) THEN
      UnitarySystem(UnitarySysNum)%LatLoadLoss = 0.0d0
    END IF

  IF (UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == AutoSize) THEN

    IF (CurOASysNum > 0) THEN
      IF(OASysEqSizing(CurOASysNum)%Capacity)THEN
        IF(OASysEqSizing(CurOASysNum)%DesHeatingLoad .GT. 0.0d0)THEN
          UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = OASysEqSizing(CurOASysNum)%DesHeatingLoad
        ELSE
          UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = OASysEqSizing(CurOASysNum)%DesCoolingLoad * &
                                                               UnitarySystem(UnitarySysNum)%HeatingSizingRatio
        END IF
      ELSE
        IF (DXCoolCap >= SmallLoad) THEN
          UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = DXCoolCap * UnitarySystem(UnitarySysNum)%HeatingSizingRatio
        ELSE
          UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = 0.0d0
        END IF
      END IF
    ELSE IF (CurZoneEqNum > 0) THEN
      IF(ZoneEqSizing(CurZoneEqNum)%Capacity)THEN
        IF(ZoneEqSizing(CurZoneEqNum)%DesHeatingLoad .GT. 0.0d0)THEN
          UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = ZoneEqSizing(CurZoneEqNum)%DesHeatingLoad
        ELSE
          UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = ZoneEqSizing(CurZoneEqNum)%DesCoolingLoad * &
                                                               UnitarySystem(UnitarySysNum)%HeatingSizingRatio
        END IF
      ELSE
        IF (DXCoolCap >= SmallLoad) THEN
          UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = DXCoolCap * UnitarySystem(UnitarySysNum)%HeatingSizingRatio
        ELSE
          UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = 0.0d0
        END IF
      END IF
    ELSE IF(DXCoolCap > 0 .AND. UnitarySystem(UnitarySysNum)%HeatPump) THEN
      IF (DXCoolCap >= SmallLoad) THEN
        UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = DXCoolCap * UnitarySystem(UnitarySysNum)%HeatingSizingRatio
      ELSE
        UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = 0.0d0
      END IF
    ELSE IF (CurSysNum > 0) THEN

      IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
          UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
          UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .OR. &
          UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHP .OR. &
          UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
          UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)  THEN
        ! for now, find the associated DX cooling coil to identically size heating coil
        DXHeatCoilBranch = 0
        DXHeatCoilCompNum = 0
        IF(UnitarySystem(UnitarySysNum)%DXHeatingCoil .AND. .NOT. UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
          BRANCHLoop: DO BranchNum = 1, PrimaryAirSystem(AirLoopNum)%NumBranches
            DO CompNum = 1, PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%TotalComponents
              IF(.NOT. SameString(PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%TypeOf, &
                           UnitarySystem(UnitarySysNum)%UnitarySystemType)) CYCLE
              IF(.NOT. SameString(PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%Name, &
                           UnitarySystem(UnitarySysNum)%Name)) CYCLE
              DXHeatCoilBranch = BranchNum
              DXHeatCoilCompNum = CompNum
              EXIT BRANCHLoop
            END DO
          END DO BRANCHLoop
        END IF
        IF(DXHeatCoilCompNum .GT. 0)THEN
          DO CompNum = PrimaryAirSystem(AirLoopNum)%Branch(DXHeatCoilBranch)%TotalComponents, 1, -1
            IF(SameString(PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%TypeOf, &
                        UnitarySystem(UnitarySysNum)%UnitarySystemType)) THEN
              IF(SameString(PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%Name, &
                        UnitarySystem(UnitarySysNum)%Name))CYCLE
              CoolCoilIndex = &
                GetUnitarySystemDXCoolingCoilIndex(PrimaryAirSystem(AirLoopNum)%Branch(DXHeatCoilBranch)%Comp(CompNum)%Name)
              IF(CoolCoilIndex .GT. 0)THEN
                CoolUnitarySystemNum = FinditemInList(PrimaryAirSystem(AirLoopNum)%Branch(DXHeatCoilBranch)%Comp(CompNum)%Name, &
                                                    UnitarySystem%Name,NumUnitarySystem)
                CoolCoilType = UnitarySystem(CoolUnitarySystemNum)%CoolingCoilType_Num
                DXCoolCap = GetCoilCapacityByIndexType(CoolCoilIndex,CoolCoilType,ErrFound)
                UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = DXCoolCap*UnitarySystem(UnitarySysNum)%HeatingSizingRatio
                EXIT
              END IF
            ELSE IF(SameString(PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%TypeOf, &
                        'CoilSystem:Cooling:DX'))THEN
              CoolCoilType  = 0
              CoolCoilIndex = 0
              CoolCoilName =' '
              CALL GetCoolingCoilTypeNameAndIndex(PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%Name, &
                                              CoolCoilType,CoolCoilIndex,CoolCoilName,ErrFound)
              SELECT CASE(CoolCoilType)
                CASE(CoilDX_CoolingSingleSpeed,CoilDX_CoolingTwoSpeed,CoilDX_CoolingTwoStageWHumControl)
                  DXCoolCap = GetCoilCapacityByIndexType(CoolCoilIndex,CoolCoilType,ErrFound)
                CASE(CoilDX_CoolingHXAssisted)
                  DXCoolCap = GetCoilCapacity(cAllCoilTypes(CoolCoilType), CoolCoilName,ErrFound)
                CASE(Coil_CoolingAirToAirVariableSpeed)
                  DXCoolCap = GetCoilCapacityByIndexType(CoolCoilIndex,CoolCoilType,ErrFound)
                ! the following CASE's are not allowed in CoilSystem:Cooling:DX
                CASE(Coil_CoolingWaterToAirHPSimple)
                  DXCoolCap = GetSimpleCoilCapacity(cAllCoilTypes(CoolCoilType), CoolCoilName,ErrFound)
                CASE(Coil_CoolingWaterToAirHP)
                  DXCoolCap = GetWAHPCoilCapacity(cAllCoilTypes(CoolCoilType), CoolCoilName,ErrFound)
                CASE(Coil_CoolingWaterToAirHPVSEquationFit)
                  DXCoolCap = GetCoilCapacityVariableSpeed(cAllCoilTypes(CoolCoilType), CoolCoilName,ErrFound)
                CASE(CoilDX_MultiSpeedCooling)
                  DXCoolCap = GetCoilCapacityByIndexType(CoolCoilIndex,CoolCoilType,ErrFound)
                CASE DEFAULT
              END SELECT

              UnitarySystem(UnitarySysNum)%CoolingCoilIndex = CoolCoilIndex
              IF(UnitarySystem(UnitarySysNum)%CoolingCoilIndex .GT. 0)THEN
                IF (DXCoolCap > 0.0d0) UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = &
                   DXCoolCap*UnitarySystem(UnitarySysNum)%HeatingSizingRatio
!                EXIT - don't exit, see if there is a UnitarySystem on the branch more upstream of the CoilSystem
              END IF
            END IF
          END DO
          IF(DXCoolCap == 0.0d0)THEN
            IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize)THEN
              VolFlowRate = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
              IF (VolFlowRate >= SmallAirVolFlow) THEN
                IF (CurOASysNum > 0) THEN ! coil is in the OA stream
                  MixTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
                  MixHumRat = FinalSysSizing(CurSysNum)%HeatOutHumRat
                  SupTemp = FinalSysSizing(CurSysNum)%PrecoolTemp
                  SupHumRat = FinalSysSizing(CurSysNum)%PrecoolHumRat
                  OutTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
                ELSE IF(CurSysNum > 0)THEN ! coil is on the main air loop
                  SupTemp = FinalSysSizing(CurSysNum)%HeatSupTemp
                  SupHumRat = FinalSysSizing(CurSysNum)%HeatSupHumRat
                  MixTemp = FinalSysSizing(CurSysNum)%HeatMixTemp
                  MixHumRat = FinalSysSizing(CurSysNum)%HeatMixHumRat
                  OutTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
                ELSE ! coil is zone equipment
                  IF (ZoneEqSizing(CurZoneEqNum)%OAVolFlow > 0.0d0) THEN
                    MixTemp = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInTemp
                    MixHumRat = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInHumRat
                  ELSE
                    MixTemp = FinalZoneSizing(CurZoneEqNum)%ZoneRetTempAtCoolPeak
                    MixHumRat = FinalZoneSizing(CurZoneEqNum)%ZoneHumRatAtCoolPeak
                  END IF
                  SupTemp = FinalZoneSizing(CurZoneEqNum)%HeatDesTemp
                  SupHumRat = FinalZoneSizing(CurZoneEqNum)%HeatDesHumRat
                  TimeStepNumAtMax = FinalZoneSizing(CurZoneEqNum)%TimeStepNumAtCoolMax
                  DDNum = FinalZoneSizing(CurZoneEqNum)%CoolDDNum
                  IF (DDNum > 0 .and. TimeStepNumAtMax > 0) THEN
                    OutTemp = DesDayWeath(DDNum)%Temp(TimeStepNumAtMax)
                  ELSE
                    OutTemp = 0.0d0
                  ENDIF
                END IF
                rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
                MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
                MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
                SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
                IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
                   UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
                  CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFound)
                  TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
                ELSE
                  TotCapTempModFac = 1.0d0
                END IF
                HeatCapAtPeak = MAX(0.0d0, (rhoair * VolFlowRate * (SupEnth-MixEnth)))
                IF(TotCapTempModFac .GT. 0.0d0)THEN
                  UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = HeatCapAtPeak / TotCapTempModFac
                ELSE
                  UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = HeatCapAtPeak
                END IF
                IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity .GT. 0.d0)THEN
                  RatedVolFlowPerRatedTotCap = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow /   &
                     UnitarySystem(UnitarySysNum)%DesignHeatingCapacity
                ELSE
                  RatedVolFlowPerRatedTotCap = 0.0d0
                END IF
                ! check capacity to make sure design volume flow per total capacity is within range
                IF (RatedVolFlowPerRatedTotCap .LT. MinRatedVolFlowPerRatedTotCap1) THEN
                  HeatCapAtPeak = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow &
                                                   / MinRatedVolFlowPerRatedTotCap1
                  UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = HeatCapAtPeak
                  DXCoolCap = HeatCapAtPeak
                ELSEIF (RatedVolFlowPerRatedTotCap .GT. MaxRatedVolFlowPerRatedTotCap1) THEN
                  HeatCapAtPeak = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow &
                                                    / MaxRatedVolFlowPerRatedTotCap1
                  UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = HeatCapAtPeak
                  DXCoolCap = HeatCapAtPeak
                END IF
              END IF ! IF (VolFlowRate >= SmallAirVolFlow) THEN
            END IF ! IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize)THEN
          END IF ! IF(DXCoolCap == 0.0d0)THEN
        ELSE
          IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize)THEN
            VolFlowRate = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow
            IF (VolFlowRate >= SmallAirVolFlow) THEN
              IF (CurOASysNum > 0) THEN ! coil is in the OA stream
                MixTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
                MixHumRat = FinalSysSizing(CurSysNum)%HeatOutHumRat
                SupTemp = FinalSysSizing(CurSysNum)%PrecoolTemp
                SupHumRat = FinalSysSizing(CurSysNum)%PrecoolHumRat
                OutTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
              ELSE IF(CurSysNum > 0)THEN ! coil is on the main air loop
                SupTemp = FinalSysSizing(CurSysNum)%HeatSupTemp
                SupHumRat = FinalSysSizing(CurSysNum)%HeatSupHumRat
                MixTemp = FinalSysSizing(CurSysNum)%HeatMixTemp
                MixHumRat = FinalSysSizing(CurSysNum)%HeatMixHumRat
                OutTemp = FinalSysSizing(CurSysNum)%HeatOutTemp
              ELSE ! coil is zone equipment
                IF (ZoneEqSizing(CurZoneEqNum)%OAVolFlow > 0.0d0) THEN
                  MixTemp = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInTemp
                  MixHumRat = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInHumRat
                ELSE
                  MixTemp = FinalZoneSizing(CurZoneEqNum)%ZoneRetTempAtCoolPeak
                  MixHumRat = FinalZoneSizing(CurZoneEqNum)%ZoneHumRatAtCoolPeak
                END IF
                SupTemp = FinalZoneSizing(CurZoneEqNum)%HeatDesTemp
                SupHumRat = FinalZoneSizing(CurZoneEqNum)%HeatDesHumRat
                TimeStepNumAtMax = FinalZoneSizing(CurZoneEqNum)%TimeStepNumAtHeatMax
                DDNum = FinalZoneSizing(CurZoneEqNum)%HeatDDNum
                IF (DDNum > 0 .and. TimeStepNumAtMax > 0) THEN
                  OutTemp = DesDayWeath(DDNum)%Temp(TimeStepNumAtMax)
                ELSE
                  OutTemp = 0.0d0
                ENDIF
              END IF
              rhoair = PsyRhoAirFnPbTdbW(StdBaroPress,MixTemp,MixHumRat,RoutineName)
              MixEnth = PsyHFnTdbW(MixTemp,MixHumRat,RoutineName)
              MixWetBulb = PsyTwbFnTdbWPb(MixTemp,MixHumRat,StdBaroPress,RoutineName)
              SupEnth = PsyHFnTdbW(SupTemp,SupHumRat,RoutineName)
              IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
                CapFTCurve = GetDXCoilCapFTCurveIndex(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFound)
                TotCapTempModFac = CurveValue(CapFTCurve,MixWetBulb,OutTemp)
              ELSE
                TotCapTempModFac = 1.0d0
              END IF
              HeatCapAtPeak = MAX(0.0d0, (rhoair * VolFlowRate * (SupEnth-MixEnth)))
              IF(TotCapTempModFac .GT. 0.0d0)THEN
                UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = HeatCapAtPeak / TotCapTempModFac
              ELSE
                UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = HeatCapAtPeak
              END IF
              DXCoolCap = UnitarySystem(UnitarySysNum)%DesignHeatingCapacity
              IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity .GT. 0.d0)THEN
                RatedVolFlowPerRatedTotCap = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow /   &
                   UnitarySystem(UnitarySysNum)%DesignHeatingCapacity
              ELSE
                RatedVolFlowPerRatedTotCap = 0.0d0
              END IF
              ! check capacity to make sure design volume flow per total capacity is within range
              IF (RatedVolFlowPerRatedTotCap .LT. MinRatedVolFlowPerRatedTotCap1) THEN
                HeatCapAtPeak = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow &
                                                 / MinRatedVolFlowPerRatedTotCap1
                UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = HeatCapAtPeak
                DXCoolCap = HeatCapAtPeak
              ELSEIF (RatedVolFlowPerRatedTotCap .GT. MaxRatedVolFlowPerRatedTotCap1) THEN
                HeatCapAtPeak = UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow &
                                                  / MaxRatedVolFlowPerRatedTotCap1
                UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = HeatCapAtPeak
                DXCoolCap = HeatCapAtPeak
              END IF
            END IF ! IF (VolFlowRate >= SmallAirVolFlow) THEN
          END IF ! IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize)THEN
        END IF ! IF(DXHeatCoilCompNum .GT. 0)THEN

      ELSE ! else not a HP heating coil
        IF (CurOASysNum > 0) THEN
          IF(OASysEqSizing(CurOASysNum)%Capacity) &
            UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = OASysEqSizing(CurOASysNum)%DesHeatingLoad
        ELSE IF (CurSysNum > 0) THEN
          IF(UnitarySysEqSizing(CurSysNum)%Capacity) &
            UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = UnitarySysEqSizing(CurSysNum)%DesHeatingLoad
        ELSE IF (CurZoneEqNum > 0) THEN
          IF(ZoneEqSizing(CurZoneEqNum)%Capacity) &
            UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = ZoneEqSizing(CurZoneEqNum)%DesHeatingLoad
        END IF
        IF (UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize) THEN
          IF (CurOASysNum > 0) THEN
            IF(OASysEqSizing(CurOASysNum)%AirFlow)THEN
              VolFlowRate = OASysEqSizing(CurOASysNum)%AirVolFlow
            ELSE
              VolFlowRate = FinalSysSizing(CurSysNum)%DesOutAirVolFlow
            END IF
          ELSE
            IF(CurZoneEqNum > 0)THEN
              IF(ZoneEqSizing(CurZoneEqNum)%AirFlow)THEN
                VolFlowRate = ZoneEqSizing(CurZoneEqNum)%AirVolFlow
              ELSE
                VolFlowRate = FinalZoneSizing(CurZoneEqNum)%DesHeatVolFlow
              END IF
            ELSE
              IF(UnitarySysEqSizing(CurSysNum)%AirFlow)THEN
                VolFlowRate = UnitarySysEqSizing(CurSysNum)%AirVolFlow
              ELSE
                SELECT CASE(CurDuctType)
                  CASE(Main)
                    VolFlowRate = FinalSysSizing(CurSysNum)%SysAirMinFlowRat*FinalSysSizing(CurSysNum)%DesMainVolFlow
                  CASE(Cooling)
                    VolFlowRate = FinalSysSizing(CurSysNum)%SysAirMinFlowRat*FinalSysSizing(CurSysNum)%DesCoolVolFlow
                  CASE(Heating)
                    VolFlowRate = FinalSysSizing(CurSysNum)%DesHeatVolFlow
                  CASE(Other)
                    VolFlowRate = FinalSysSizing(CurSysNum)%DesMainVolFlow
                  CASE DEFAULT
                    VolFlowRate = FinalSysSizing(CurSysNum)%DesMainVolFlow
                END SELECT
              END IF
            END IF
          END IF
          ! get the outside air fraction
          IF (CurOASysNum > 0) THEN
            OutAirFrac = 1.0d0
          ELSE IF (CurSysNum > 0) THEN
            IF (FinalSysSizing(CurSysNum)%HeatOAOption == MinOA) THEN
              IF (VolFlowRate > 0.0d0) THEN
                OutAirFrac = FinalSysSizing(CurSysNum)%DesOutAirVolFlow / VolFlowRate
              ELSE
                OutAirFrac = 1.0d0
              END IF
            ELSE
              OutAirFrac = 1.0d0
            END IF
            OutAirFrac = MIN(1.0d0,MAX(0.0d0,OutAirFrac))
          ELSE
            OutAirFrac = 1.0d0
          END IF
          ! coil inlet temperature
          IF (CurZoneEqNum > 0) THEN
            MixTemp = FinalZoneSizing(CurZoneEqNum)%DesHeatCoilInTemp
            CpAirStd = PsyCpAirFnWTdb(0.0d0,20.0d0)
            HeatCapAtPeak = CpAirStd*StdRhoAir*VolFlowRate*(FinalZoneSizing(CurZoneEqNum)%HeatDesTemp - MixTemp)
            ZoneEqSizing(CurZoneEqNum)%Capacity = .TRUE.
            ZoneEqSizing(CurZoneEqNum)%DesHeatingLoad = HeatCapAtPeak
          ELSE
            IF (CurOASysNum == 0 .AND. PrimaryAirSystem(CurSysNum)%NumOAHeatCoils > 0) THEN
              MixTemp = OutAirFrac*FinalSysSizing(CurSysNum)%PreheatTemp + &
                         (1.0d0-OutAirFrac)*FinalSysSizing(CurSysNum)%HeatRetTemp
            ELSE
              MixTemp = OutAirFrac*FinalSysSizing(CurSysNum)%HeatOutTemp + &
                         (1.0d0-OutAirFrac)*FinalSysSizing(CurSysNum)%HeatRetTemp
            END IF
            ! coil load
            IF (CurOASysNum > 0) THEN
              IF(OASysEqSizing(CurOASysNum)%Capacity)THEN
                HeatCapAtPeak = OASysEqSizing(CurOASysNum)%DesHeatingLoad
              ELSE
                CpAirStd = PsyCpAirFnWTdb(0.0d0,20.0d0)
                HeatCapAtPeak = CpAirStd*StdRhoAir*VolFlowRate*(FinalSysSizing(CurSysNum)%PreheatTemp - MixTemp)
              END IF
            ELSE
              IF(UnitarySysEqSizing(CurSysNum)%Capacity)THEN
                HeatCapAtPeak = UnitarySysEqSizing(CurSysNum)%DesHeatingLoad
              ELSE
                CpAirStd = PsyCpAirFnWTdb(0.0d0,20.0d0)
                HeatCapAtPeak = CpAirStd*StdRhoAir*VolFlowRate*(FinalSysSizing(CurSysNum)%HeatSupTemp - MixTemp)
              END IF
            END IF
            UnitaryHeatCap = HeatCapAtPeak
          END IF
          UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = HeatCapAtPeak
        END IF
      END IF

      IF (UnitarySystem(UnitarySysNum)%DesignHeatingCapacity < SmallLoad) THEN
        UnitarySystem(UnitarySysNum)%DesignHeatingCapacity = 0.0d0
      END IF

    END IF

    CALL ReportSizingOutput(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name, &
                            'Nominal Heating Capacity [W]', &
                            UnitarySystem(UnitarySysNum)%DesignHeatingCapacity)

  END IF

  UnitaryHeatCap = UnitarySystem(UnitarySysNum)%DesignHeatingCapacity

  IF (UnitarySystem(UnitarySysNum)%DesignCoolingCapacity == AutoSize) THEN

    IF (CurOASysNum > 0) THEN
      IF (DXCoolCap >= SmallLoad) THEN
        UnitarySystem(UnitarySysNum)%DesignCoolingCapacity = DXCoolCap
      ELSE
        UnitarySystem(UnitarySysNum)%DesignCoolingCapacity = 0.0d0
      END IF
    ELSE IF (CurZoneEqNum > 0) THEN

      IF (DXCoolCap >= SmallLoad) THEN
        UnitarySystem(UnitarySysNum)%DesignCoolingCapacity = DXCoolCap
      ELSE
        UnitarySystem(UnitarySysNum)%DesignCoolingCapacity = 0.0d0
      END IF
    ELSE IF (CurSysNum > 0) THEN

      IF (DXCoolCap >= SmallLoad) THEN
        UnitarySystem(UnitarySysNum)%DesignCoolingCapacity = DXCoolCap
      ELSE
        UnitarySystem(UnitarySysNum)%DesignCoolingCapacity = 0.0d0
      END IF
    END IF

    CALL ReportSizingOutput(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name, &
                            'Nominal Cooling Capacity [W]', &
                            UnitarySystem(UnitarySysNum)%DesigncoolingCapacity)

  END IF

  IF (UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp == AutoSize .AND. &
      (UnitarySystem(UnitarySysNum)%HeatCoilExists .OR. UnitarySystem(UnitarySysNum)%SuppCoilExists)) THEN

    IF (CurOASysNum > 0) THEN
      UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp = FinalSysSizing(CurSysNum)%HeatSupTemp
    ELSE IF (CurZoneEqNum > 0) THEN
      UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp = FinalZoneSizing(CurZoneEqNum)%HeatDesTemp
    ELSE IF (CurSysNum > 0) THEN
      UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp = FinalSysSizing(CurSysNum)%HeatSupTemp
    END IF

    CALL ReportSizingOutput(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name, &
                            'Maximum Supply Air Temperature from Unitary Heater [C]', &
                            UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp)

  END IF

  IF (UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity == AutoSize) THEN

    IF (CurOASysNum > 0) THEN
      UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity = FinalSysSizing(CurSysNum)%HeatCap
    ELSE IF (CurZoneEqNum > 0) THEN
      UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity = FinalZoneSizing(CurZoneEqNum)%DesHeatLoad
    ELSE IF (CurSysNum > 0) THEN

      ! set the supplemental heating capacity to the actual heating load
      UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity = FinalSysSizing(CurSysNum)%HeatCap
      ! If reheat needed for humidity control, make sure supplemental heating is at least as big
      ! as the cooling capacity
      IF (UnitarySystem(UnitarySysNum)%Humidistat .AND. &
          UnitarySystem(UnitarySysNum)%DehumidControlType_Num == DehumidControl_CoolReheat) THEN
        UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity = MAX(UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity, &
                                                            UnitarySystem(UnitarySysNum)%DesignCoolingCapacity)
        IF (UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity < SmallLoad) THEN
          UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity = 0.0d0
        END IF
      END IF

    END IF

    CALL ReportSizingOutput(UnitarySystem(UnitarySysNum)%UnitarySystemType, UnitarySystem(UnitarySysNum)%Name, &
                            'Supplemental Heating Coil Nominal Capacity [W]', &
                            UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity)

  END IF

  SuppHeatCap = UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity

  IF (UnitarySystem(UnitarySysNum)%HeatRecActive) THEN
    CALL RegisterPlantCompDesignFlow(UnitarySystem(UnitarySysNum)%HeatRecoveryInletNodeNum, &
                              UnitarySystem(UnitarySysNum)%DesignHRWaterVolumeFlow )
  END IF

  IF(CurOASysNum .EQ. 0 .AND. CurZoneEqNum .EQ. 0)THEN
    BranchFlow = 0.0d0
    SystemType = cFurnaceTypes(UnitarySystem(UnitarySysNum)%UnitarySystemType_Num)
    ErrFound  = .FALSE.
    ! check branch flow rate vs system flow rate. Branch must match system of OA system is present
    CALL CheckSystemBranchFlow(TRIM(SystemType),UnitarySystem(UnitarySysNum)%Name, &
                               BranchFlow,UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate,ErrFound)
    IF(ErrFound)CALL ShowContinueError('...occurs in '//TRIM(SystemType)//' "'//TRIM(UnitarySystem(UnitarySysNum)%Name))
    IF(UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate .LE. 0.0d0)THEN
      IF(BranchFlow .NE. Autosize)THEN
        UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = BranchFlow
      ELSE
        UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = MAX(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow, &
                                                                UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow)
      END IF
      UnitarySystem(UnitarySysNum)%DesignMassFlowRate = UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate * StdRhoAir
    END IF
  END IF

  CoolingLoad = TempCoolingLoad
  HeatingLoad = TempHeatingLoad

  RETURN

END SUBROUTINE SizeUnitarySystem


! Get Input Section of the Module
!******************************************************************************
SUBROUTINE GetUnitarySystemInput

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   February 2013
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! Obtains input data for system and stores it in System data structures

          ! METHODOLOGY EMPLOYED:
          ! Uses "Get" routines to read in data.

          ! REFERENCES:

          ! USE STATEMENTS:
    USE InputProcessor
    USE NodeInputManager,           ONLY: GetOnlySingleNode
    USE DataHeatBalance,            ONLY: Zone
    USE BranchNodeConnections,      ONLY: SetUpCompSets, TestCompSet
    USE HVACHXAssistedCoolingCoil,  ONLY: GetHXDXCoilName
    USE DataIPShortCuts
    USE General,                    ONLY: TrimSigDigits
    USE DataHVACControllers,        ONLY: ControllerTypes, ControllerSimple_Type
    USE DXCoils,                    ONLY: SetCoilSystemCoolingData, GetDXCoilAvailSchPtr,SetDXCoolingCoilData
    USE DataAirSystems,             ONLY: PrimaryAirSystem
    USE DataZoneControls,           ONLY: TempControlledZone, NumTempControlledZones, HumidityControlZone,   &
                                          NumHumidityControlZones, ComfortControlledZone, NumComfortControlledZones
    USE WaterToAirHeatPumpSimple,   ONLY: GetWtoAHPSimpleCoilCapacity=>GetCoilCapacity,  &
                                          GetWtoAHPSimpleCoilInletNode=>GetCoilInletNode, &
                                          GetWtoAHPSimpleCoilOutletNode=>GetCoilOutletNode, &
                                          GetWtoAHPSimpleCoilIndex=>GetCoilIndex, &
                                          SetSimpleWSHPData, GetWtoAHPSimpleCoilAirFlow=>GetCoilAirFlowRate
    USE VariableSpeedCoils,         ONLY: GetCoilCapacityVariableSpeed, &
                                          GetCoilInletNodeVariableSpeed, &
                                          GetCoilOutletNodeVariableSpeed, &
                                          GetCoilIndexVariableSpeed, &
                                          GetCoilAirFlowRateVariableSpeed,&
                                          SetVarSpeedCoilData, GetVSCoilCondenserInletNode, &
                                          GetVSCoilMinOATCompressor, GetVSCoilNumOfSpeeds
    USE WaterToAirHeatPump,         ONLY: GetWtoAHPCoilCapacity=>GetCoilCapacity, &
                                          GetWtoAHPCoilInletNode=>GetCoilInletNode, &
                                          GetWtoAHPCoilOutletNode=>GetCoilOutletNode,GetWtoAHPCoilIndex=>GetCoilIndex
    USE HeatingCoils,               ONLY: GetHeatingCoilCapacity=>GetCoilCapacity,GetHeatingCoilInletNode=>GetCoilInletNode, &
                                          GetHeatingCoilOutletNode=>GetCoilOutletNode, GetHeatingCoilIndex=>GetCoilIndex, &
                                          GetHeatingCoilTypeNum, GetHeatingCoilPLFCurveIndex, GetCoilAvailScheduleIndex
    USE DXCoils,                    ONLY: GetDXCoilCapacity=>GetCoilCapacity,GetMinOATDXCoilCompressor=>GetMinOATCompressor,  &
                                          GetDXCoilInletNode=>GetCoilInletNode, GetDXCoilOutletNode=>GetCoilOutletNode, &
                                          GetDXCoilCondenserInletNode=>GetCoilCondenserInletNode,GetDXCoilIndex, &
                                          GetDXCoilTypeNum=>GetCoilTypeNum,SetDXCoolingCoilData,GetDXCoilAirFlow,SetDXCoilTypeData
    USE HVACHXAssistedCoolingCoil,  ONLY: GetDXHXAsstdCoilCapacity=>GetCoilCapacity,GetDXHXAsstdCoilInletNode=>GetCoilInletNode, &
                                          GetDXHXAsstdCoilOutletNode=>GetCoilOutletNode,GetHXDXCoilName,GetHXDXCoilIndex, &
                                          GetHXAssistedCoilTypeNum=>GetCoilGroupTypeNum, GetActualDXCoilIndex, &
                                          GetWaterHXAssistedCoilCapacity=>GetCoilCapacity, GetHXCoilAirFlowRate,   &
                                          GetCoilObjectTypeNum
    USE WaterCoils,                 ONLY: GetCoilWaterInletNode, GetCoilWaterOutletNode, GetCoilMaxWaterFlowRate, &
                                          GetWaterCoilInletNode=>GetCoilInletNode,GetWaterCoilOutletNode=>GetCoilOutletNode, &
                                          GetWaterCoilAvailScheduleIndex, GetWaterCoilIndex
    USE SteamCoils,                 ONLY: GetSteamCoilAirInletNode=>GetCoilAirInletNode, GetSteamCoilIndex, &
                                          GetSteamCoilAirOutletNode=>GetCoilAirOutletNode, &
                                          GetSteamCoilSteamInletNode=>GetCoilSteamInletNode, &
                                          GetCoilMaxSteamFlowRate=>GetCoilMaxSteamFlowRate, ZoneLoadControl, &
                                          GetSteamCoilAvailScheduleIndex
    USE Fans,                       ONLY: GetFanDesignVolumeFlowRate,GetFanInletNode,GetFanOutletNode,GetFanIndex, &
                                          GetFanAvailSchPtr, GetFanType, GetFanIndex
    USE FluidProperties,            ONLY: GetSatDensityRefrig
    USE EMSManager,                 ONLY: ManageEMS
    USE SetPointManager,            ONLY: NodeHasSPMCtrlVarType, iCtrlVarType_Temp, iCtrlVarType_HumRat

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
          ! na

          ! SUBROUTINE PARAMETER DEFINITIONS:
  CHARACTER(len=*), PARAMETER :: RoutineName='GetUnitarySystemInput: ' ! include trailing blank space

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
    CHARACTER(len=MaxNameLength), ALLOCATABLE, DIMENSION(:) :: Alphas         ! Alpha input items for object
    CHARACTER(len=MaxNameLength), ALLOCATABLE, DIMENSION(:) :: cAlphaFields   ! Alpha field names
    CHARACTER(len=MaxNameLength), ALLOCATABLE, DIMENSION(:) :: cNumericFields ! Numeric field names
    CHARACTER(len=MaxNameLength) :: CurrentModuleObject ! for ease in getting objects
    CHARACTER(len=MaxNameLength) :: CoolingCoilType     ! Used in mining function calls
    CHARACTER(len=MaxNameLength) :: CoolingCoilName     ! Used in mining function calls
    CHARACTER(len=MaxNameLength) :: HeatingCoilType     ! Used in mining function calls
    CHARACTER(len=MaxNameLength) :: HeatingCoilName     ! Used in mining function calls
    REAL(r64)                    :: HeatingSizingRatio  ! Used to size DX heating coil wrt DX cooling coil
    CHARACTER(len=MaxNameLength) :: SuppHeatCoilType    ! Used in mining function calls
    CHARACTER(len=MaxNameLength) :: SuppHeatCoilName    ! Used in mining function calls
    CHARACTER(len=MaxNameLength) :: FanType             ! Used in mining function calls
    CHARACTER(len=MaxNameLength) :: FanName             ! Used in mining function calls
    INTEGER                      :: FanIndex            ! Used in mining function calls
    LOGICAL, ALLOCATABLE, DIMENSION(:)   :: lAlphaBlanks      ! Logical array, alpha field input BLANK = .true.
    LOGICAL, ALLOCATABLE, DIMENSION(:)   :: lNumericBlanks    ! Logical array, numeric field input BLANK = .true.
    REAL(r64), ALLOCATABLE, DIMENSION(:) :: Numbers     ! Numeric input items for object
    REAL(r64)  :: FanVolFlowRate                        ! Fan Max Flow Rate from Fan object (for comparisons to validity)
    REAL(r64)  :: SteamDensity                          ! steam density
    REAL(r64)  :: TotalFloorAreaOnAirLoop               ! AirloopHVAC total floor area served
    LOGICAL    :: ErrorsFound = .FALSE.                 ! If errors detected in input
    LOGICAL    :: IsNotOK                               ! Flag to verify name
    LOGICAL    :: IsBlank                               ! Flag for blank name
    LOGICAL    :: AirNodeFound                          ! used in error checking
    LOGICAL    :: AirLoopFound                          ! used in error checking
    LOGICAL    :: ErrFlag                               ! Mining function error flag
    LOGICAL    :: PrintMessage                          ! flag to print or not print message
    LOGICAL    :: InletNodeNotControlled                ! True if using controller on water coil
    INTEGER    :: UnitarySysNum                         ! The Unitary System object currently loading
    INTEGER    :: DesignSpecNum                         ! The design Specification object (multispeed coils) currently loading
    INTEGER    :: NumAlphas                             ! The number of alpha arguments in each object
    INTEGER    :: NumNumbers                            ! The number of numeric arguments in each object
    INTEGER    :: IOStatus                              ! The status of the GetObjectItem call
    INTEGER    :: TotalArgs=0                           ! Total number of alpha and numeric arguments (max) for a
                                                        ! certain object in the input file
    INTEGER    :: FanInletNode                          ! Used for node checking warning messages
    INTEGER    :: FanOutletNode                         ! Used for node checking warning messages
    INTEGER    :: CoolingCoilInletNode                  ! Used for node checking warning messages
    INTEGER    :: CoolingCoilOutletNode                 ! Used for node checking warning messages
    INTEGER    :: HeatingCoilInletNode                  ! Used for node checking warning messages
    INTEGER    :: HeatingCoilOutletNode                 ! Used for node checking warning messages
    INTEGER    :: SupHeatCoilInletNode                  ! Used for node checking warning messages
    INTEGER    :: SupHeatCoilOutletNode                 ! Used for node checking warning messages
    INTEGER    :: TotalZonesOnAirLoop                   ! number of zones connected to air loop
    LOGICAL    :: ZoneEquipmentFound                    ! TRUE if Unitary System found connected to zone exhaust node
    INTEGER    :: ActualCoolCoilType                    ! Coil type number for HX assisted coils
    INTEGER    :: ControlledZoneNum                     ! loop counter
    INTEGER    :: ZoneExhNum                            ! loop counter
    INTEGER    :: EquipNum                              ! loop counter
    INTEGER    :: ZoneInletNum                          ! loop counter
    INTEGER    :: AirLoopNumber                         ! loop counter
    INTEGER    :: BranchNum                             ! loop counter
    INTEGER    :: CompNum                               ! loop counter
    INTEGER    :: OACompNum                             ! loop counter
    INTEGER    :: TstatZoneNum                          ! loop counter
    INTEGER    :: HeatingCoilPLFCurveIndex              ! index of heating coil PLF curve
    INTEGER    :: SteamIndex                            ! steam index
    INTEGER    :: DXCoilIndex                           ! index to DX coil
    INTEGER    :: HSTATZoneNum                          ! zone index where humidistat is located
    INTEGER    :: TempAlphas                            ! temp alpha array
    INTEGER    :: TempNumbers                           ! temp number array
    INTEGER    :: Index                                 ! index to multispeed coil speed data
    INTEGER    :: SpeedNum                              ! multispeed coil speed
    INTEGER    :: NumOfSpeedCooling                     ! number of cooling speeds for multispeed coil
    INTEGER    :: NumOfSpeedHeating                     ! number of heating speeds for multispeed coil
    INTEGER    :: StartingSpeedRatioInput               ! field where speed ratio inputs start
    INTEGER    :: MaxSpeedNum                           ! maximum number of numeric inputs in design specification object
    INTEGER    :: OASysNum                              ! loop counter index to outside air system
    INTEGER    :: AirLoopNum                            ! loop counter index to primary air system
    CHARACTER(len=MaxNameLength)   :: HXCoilName        ! Cooling coil name within HX assembly

    ! local integer representation of input field numbers (i.e., alpha=A1 or numeric=N1)
    INTEGER    :: iNameAlphaNum                         ! get input index to unitary system name
    INTEGER    :: iControlTypeAlphaNum                  ! get input index to unitary system control type
    INTEGER    :: iControlZoneAlphaNum                  ! get input index to unitary system control zone
    INTEGER    :: iDehumidControlAlphaNum               ! get input index to unitary system dehumidification control
    INTEGER    :: iSysAvailSchedAlphaNum                ! get input index to unitary system avail schedule
    INTEGER    :: iFanTypeAlphaNum                      ! get input index to unitary system fan type
    INTEGER    :: iFanNameAlphaNum                      ! get input index to unitary system fan name
    INTEGER    :: iFanPlaceAlphaNum                     ! get input index to unitary system fan placement
    INTEGER    :: iFanSchedAlphaNum                     ! get input index to unitary system fan mode op schedule
    INTEGER    :: iHeatingCoilTypeAlphaNum              ! get input index to unitary system heating coil type
    INTEGER    :: iHeatingCoilNameAlphaNum              ! get input index to unitary system heating coil name
    INTEGER    :: iHeatingCoilSizeRatioNumericNum       ! get input index to unitary system heating coil sizing ratio
    INTEGER    :: iCoolingCoilTypeAlphaNum              ! get input index to unitary system cooling coil type
    INTEGER    :: iCoolingCoilNameAlphaNum              ! get input index to unitary system cooling coil name
    INTEGER    :: iDOASDXCoilAlphaNum                   ! get input index to unitary system DX coil DOAS specified
    INTEGER    :: iRunOnLatentLoadAlphaNum              ! get input index to unitary system run on latent load
    INTEGER    :: iSuppHeatCoilTypeAlphaNum             ! get input index to unitary system supp heat coil type
    INTEGER    :: iSuppHeatCoilNameAlphaNum             ! get input index to unitary system supp heat coil name
    INTEGER    :: iHeatSAFMAlphaNum                     ! get input index to unitary system heat supp air flow method
    INTEGER    :: iCoolSAFMAlphaNum                     ! get input index to unitary system cool supp air flow method
    INTEGER    :: iMaxCoolAirVolFlowNumericNum          ! get input index to unitary system cool supply air flow
    INTEGER    :: iMaxHeatAirVolFlowNumericNum          ! get input index to unitary system heat supply air flow
    INTEGER    :: iNoCoolHeatSAFMAlphaNum               ! get input index to unitary system no cool/heat supply air flow
    INTEGER    :: iMaxNoCoolHeatAirVolFlowNumericNum    ! get input index to unitary system no cool/heat supply air flow
    INTEGER    :: iDesignSpecMSHPTypeAlphaNum           ! get input index to unitary system MSHP coil type
    INTEGER    :: iDesignSpecMSHPNameAlphaNum           ! get input index to unitary system MSHP coil name
    INTEGER    :: iAirInletNodeNameAlphaNum             ! get input index to unitary system air inlet node
    INTEGER    :: iAirOutletNodeNameAlphaNum            ! get input index to unitary system air outlet node
    INTEGER    :: iDOASDXMinTempNumericNum              ! get input index to unitary system DOAS DX coil min outlet temp
    INTEGER    :: iCoolFlowPerFloorAreaNumericNum       ! get input index to unitary system cool flow per floor area
    INTEGER    :: iCoolFlowPerFracCoolNumericNum        ! get input index to unitary system cool flow per fraction cool
    INTEGER    :: iCoolFlowPerCoolCapNumericNum         ! get input index to unitary system cool flow per cooling cap
    INTEGER    :: iHeatFlowPerFloorAreaNumericNum       ! get input index to unitary system heat flow per floor area
    INTEGER    :: iHeatFlowPerFracCoolNumericNum        ! get input index to unitary system heat flow per fraction heat
    INTEGER    :: iHeatFlowPerHeatCapNumericNum         ! get input index to unitary system heat flow per heating cap
    INTEGER    :: iNoCoolHeatFlowPerFloorAreaNumericNum ! get input index to unitary system no cool/heat FPA
    INTEGER    :: iNoCoolHeatFlowPerFracCoolNumericNum  ! get input index to unitary system no cool/heat FPFC
    INTEGER    :: iNoCoolHeatFlowPerFracHeatNumericNum  ! get input index to unitary system no cool/heat FPFH
    INTEGER    :: iNoCoolHeatFlowPerCoolCapNumericNum   ! get input index to unitary system no cool/heat FPCC
    INTEGER    :: iNoCoolHeatFlowPerHeatCapNumericNum   ! get input index to unitary system no cool/heat FPHC
    INTEGER    :: iDesignMaxOutletTempNumericNum        ! get input index to unitary system design max outlet temp
    INTEGER    :: iMaxOATSuppHeatNumericNum             ! get input index to unitary system maximum OAT for supp operation
    INTEGER    :: iCondenserNodeAlphaNum                ! get input index to unitary system condenser node
    INTEGER    :: iMaxONOFFCycPerHourNumericNum         ! get input index to unitary system WSHP max cycle per hour
    INTEGER    :: iHPTimeConstantNumericNum             ! get input index to unitary system WSHP time constant
    INTEGER    :: iOnCyclePowerFracNumericNum           ! get input index to unitary system WSHP on cycle power
    INTEGER    :: iFanDelayTimeNumericNum               ! get input index to unitary system WSHP off cycle power
    INTEGER    :: iAncillaryOnPowerNumericNum           ! get input index to unitary system ancillary on power
    INTEGER    :: iAncillaryOffPowerNumericNum          ! get input index to unitary system ancillary off power
    INTEGER    :: iDesignHRWaterVolFlowNumericNum       ! get input index to unitary system design HR water flow
    INTEGER    :: iMaxHROutletWaterTempNumericNum       ! get input index to unitary system max HR outlet temp
    INTEGER    :: iHRWaterInletNodeAlphaNum             ! get input index to unitary system HR water inlet node
    INTEGER    :: iHRWaterOutletNodeAlphaNum            ! get input index to unitary system HR water outlet node

    CurrentModuleObject='AirloopHVAC:UnitarySystem'
    NumUnitarySystem = GetNumObjectsFound(TRIM(CurrentModuleObject))

    ALLOCATE(UnitarySystem(NumUnitarySystem))
    ALLOCATE(CheckEquipName(NumUnitarySystem))
    ALLOCATE(MultiOrVarSpeedHeatCoil(NumUnitarySystem))
    ALLOCATE(MultiOrVarSpeedCoolCoil(NumUnitarySystem))
    CheckEquipName = .TRUE.
    MultiOrVarSpeedHeatCoil = .FALSE.
    MultiOrVarSpeedCoolCoil = .FALSE.


    CALL GetObjectDefMaxArgs(TRIM(CurrentModuleObject),TotalArgs,NumAlphas,NumNumbers)
    TempAlphas = NumAlphas
    TempNumbers = NumNumbers

    CurrentModuleObject='UnitarySystemPerformance:HeatPump:Multispeed'
    NumDesignSpecMultiSpeedHP = GetNumObjectsFound(TRIM(CurrentModuleObject))
    CALL GetObjectDefMaxArgs(TRIM(CurrentModuleObject),TotalArgs,NumAlphas,NumNumbers)

    NumAlphas = MAX(TempAlphas, NumAlphas)
    NumNumbers = MAX(TempNumbers, NumNumbers)

    ALLOCATE(Alphas(NumAlphas))
    Alphas=' '
    ALLOCATE(cAlphaFields(NumAlphas))
    cAlphaFields=' '
    ALLOCATE(cNumericFields(NumNumbers))
    cNumericFields=' '
    ALLOCATE(Numbers(NumNumbers))
    Numbers=0.0d0
    ALLOCATE(lAlphaBlanks(NumAlphas))
    lAlphaBlanks=.TRUE.
    ALLOCATE(lNumericBlanks(NumNumbers))
    lNumericBlanks=.TRUE.

      ! Get the data for the DesignSpecification object
      CurrentModuleObject='UnitarySystemPerformance:HeatPump:Multispeed'
      ALLOCATE(DesignSpecMSHP(NumDesignSpecMultiSpeedHP))

      DO DesignSpecNum = 1, NumDesignSpecMultiSpeedHP

        CALL GetObjectItem(TRIM(CurrentModuleObject),DesignSpecNum,Alphas,NumAlphas,Numbers,NumNumbers,IOStatus, &
                           NumBlank=lNumericBlanks,AlphaBlank=lAlphaBlanks, &
                           AlphaFieldNames=cAlphaFields,NumericFieldNames=cNumericFields)

        IsNotOK=.FALSE.
        IsBlank=.FALSE.
        CALL VerifyName(Alphas(1),DesignSpecMSHP%Name,DesignSpecNum-1,IsNotOK,IsBlank,TRIM(CurrentModuleObject)//' Name')
        IF (IsNotOK) THEN
          ErrorsFound=.TRUE.
          IF (IsBlank) Alphas(1)='xxxxx'
        END IF

        DesignSpecMSHP(DesignSpecNum)%Name = Alphas(1)

        DesignSpecMSHP(DesignSpecNum)%NumOfSpeedHeating = Numbers(1)
        NumOfSpeedHeating = DesignSpecMSHP(DesignSpecNum)%NumOfSpeedHeating

        DesignSpecMSHP(DesignSpecNum)%NumOfSpeedCooling = Numbers(2)
        NumOfSpeedCooling = DesignSpecMSHP(DesignSpecNum)%NumOfSpeedCooling

        ! initialize number of speeds (MIN = 4 or greater of cooling and heating speeds x 2)
        MaxSpeedNum = 0 ! set to 0 so we know if the inputs are valid

        IF(MOD(REAL(NumNumbers-2,r64),2.0d0) .GT. 0.0d0)THEN
          ! check that the number of numeric speed input fields match the number of speeds
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(DesignSpecMSHP(DesignSpecNum)%Name))
          CALL ShowContinueError('Illegal number of entries in Supply Air Flow Rate fields.')
          CALL ShowContinueError('..number of required Supply Air Flow Rate fields = '// &
               TRIM(TrimSigDigits(2*(MAX(NumOfSpeedCooling,NumOfSpeedHeating)),0)))
          CALL ShowContinueError('..number of actual Supply Air Flow Rate fields   = '//TRIM(TrimSigDigits((NumNumbers-2),0)))
          ErrorsFound=.TRUE.
        ELSE
          MaxSpeedNum = (NumNumbers-2)/2 ! Extensible fields included (>4) for cooling and heating
        END IF

        IF(MaxSpeedNum .LT. MAX(NumOfSpeedHeating,NumOfSpeedCooling))THEN
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(DesignSpecMSHP(DesignSpecNum)%Name))
          CALL ShowContinueError('Illegal number of entries in Supply Air Flow Rate fields.')
          CALL ShowContinueError('..number of required Supply Air Flow Rate fields = '// &
               TRIM(TrimSigDigits(2*(MAX(NumOfSpeedCooling,NumOfSpeedHeating)),0)))
          CALL ShowContinueError('..number of actual Supply Air Flow Rate fields   = '//TRIM(TrimSigDigits((NumNumbers-2),0)))
          ErrorsFound=.TRUE.
        END IF

        StartingSpeedRatioInput = 3 ! start the index counter at the first input for heating (e.g. 3+0*2)
        IF(NumOfSpeedHeating .GT. 0 .AND. MaxSpeedNum > 0) THEN
          ALLOCATE(DesignSpecMSHP(DesignSpecNum)%HeatingVolFlowRatio(MaxSpeedNum))
          DO SpeedNum = 1, NumOfSpeedHeating
            DesignSpecMSHP(DesignSpecNum)%HeatingVolFlowRatio(SpeedNum) = Numbers(StartingSpeedRatioInput+((SpeedNum-1)*2))
          END DO
        END IF

        StartingSpeedRatioInput = 4 ! start the index counter at the first input for heating (e.g. 4+0*2)
        IF(NumOfSpeedCooling .GT. 0 .AND. MaxSpeedNum > 0) THEN
          ALLOCATE(DesignSpecMSHP(DesignSpecNum)%CoolingVolFlowRatio(MaxSpeedNum))
          DO SpeedNum = 1, NumOfSpeedCooling
            DesignSpecMSHP(DesignSpecNum)%CoolingVolFlowRatio(SpeedNum) = Numbers(StartingSpeedRatioInput+((SpeedNum-1)*2))
          END DO
        END IF

      END DO

      ! AirLoopHVAC:UnitarySystem,
      iNameAlphaNum                   = 1  ! A1,  \field Name - \required-field
      iControlTypeAlphaNum            = 2  ! A2,  \field Control Type
      iControlZoneAlphaNum            = 3  ! A3,  \field Controlling Zone or Thermostat Location
      iDehumidControlAlphaNum         = 4  ! A4,  \field dehumidification Control Type
      iSysAvailSchedAlphaNum          = 5  ! A5,  \field Availability Schedule Name
      iAirInletNodeNameAlphaNum       = 6  ! A6,  \field Air Inlet Node Name - \required-field
      iAirOutletNodeNameAlphaNum      = 7  ! A7,  \field Air Outlet Node Name - \required-field
      iFanTypeAlphaNum                = 8  ! A8,  \field Supply Fan Object Type
      iFanNameAlphaNum                = 9  ! A9,  \field Supply Fan Name
      iFanPlaceAlphaNum               = 10 ! A10, \field Fan Placement
      iFanSchedAlphaNum               = 11 ! A11, \field Supply Air Fan Operating Mode Schedule Name
      iHeatingCoilTypeAlphaNum        = 12 ! A12, \field Heating Coil Object Type
      iHeatingCoilNameAlphaNum        = 13 ! A13, \field Heating Coil Name
      iHeatingCoilSizeRatioNumericNum = 1  ! N1,  \field DX Heating Coil Sizing Ratio
      iCoolingCoilTypeAlphaNum        = 14 ! A14, \field Cooling Coil Object Type
      iCoolingCoilNameAlphaNum        = 15 ! A15, \field Cooling Coil Name
      iDOASDXCoilAlphaNum             = 16 ! A16, \field Use DOAS DX Cooling Coil
      iDOASDXMinTempNumericNum        = 2  ! N2 , \field DOAS DX Cooling Coil Leaving Minimum Air Temperature
      iRunOnLatentLoadAlphaNum        = 17 ! A17, \field Run on Latent Load
      iSuppHeatCoilTypeAlphaNum       = 18 ! A18, \field Supplemental Heating Coil Object Type
      iSuppHeatCoilNameAlphaNum       = 19 ! A19, \field Supplemental Heating Coil Name
      iCoolSAFMAlphaNum               = 20 ! A20, \field Supply air Flow Rate Method During Cooling Operation
      iMaxCoolAirVolFlowNumericNum    = 3  ! N3,  \field Supply Air Flow Rate During Cooling Operation
      iCoolFlowPerFloorAreaNumericNum = 4  ! N4,  \field Supply Air Flow Rate Per Floor Area During Cooling Operation
      iCoolFlowPerFracCoolNumericNum  = 5  ! N5,  \field Fraction of Autosized Design Cooling Supply Air Flow Rate
      iCoolFlowPerCoolCapNumericNum   = 6  ! N6,  \field Design Supply Air Flow Rate Per Unit of Capacity During Cooling Operation
      iHeatSAFMAlphaNum               = 21 ! A21, \field Supply air Flow Rate Method During Heating Operation
      iMaxHeatAirVolFlowNumericNum    = 7  ! N7,  \field Supply Air Flow Rate During Heating Operation
      iHeatFlowPerFloorAreaNumericNum = 8  ! N8,  \field Supply Air Flow Rate Per Floor Area during Heating Operation
      iHeatFlowPerFracCoolNumericNum  = 9  ! N9,  \field Fraction of Autosized Design Heating Supply Air Flow Rate
      iHeatFlowPerHeatCapNumericNum   = 10 ! N10, \field Design Supply Air Flow Rate Per Unit of Capacity During Heating Operation
      iNoCoolHeatSAFMAlphaNum         = 22 ! A22, \field Supply air Flow Rate Method When No Cooling or Heating is Required
      iMaxNoCoolHeatAirVolFlowNumericNum = 11 ! N11, \field Supply Air Flow Rate When No Cooling or Heating is Required
      iNoCoolHeatFlowPerFloorAreaNumericNum = 12 ! N12, \field Supply Air Flow Rate Per Floor Area When No Cooling/Heating is Req
      iNoCoolHeatFlowPerFracCoolNumericNum = 13 ! N13, \field Fraction of Autosized Design Cooling Supply Air Flow Rate
      iNoCoolHeatFlowPerFracHeatNumericNum = 14 ! N14, \field Fraction of Autosized Design Heating Supply Air Flow Rate
      iNoCoolHeatFlowPerCoolCapNumericNum = 15 ! N15, \field Design Supply Air Flow Rate Per Unit of Capacity During Cooling Op
      iNoCoolHeatFlowPerHeatCapNumericNum = 16 ! N16, \field Design Supply Air Flow Rate Per Unit of Capacity During Heating Op
      iDesignMaxOutletTempNumericNum  = 17 ! N17, \field Maximum Supply Air Temperature
      iMaxOATSuppHeatNumericNum       = 18 ! N18, \field Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Op
      iCondenserNodeAlphaNum          = 23 ! A23, \field Outdoor Dry-Bulb Temperature Sensor Node Name
      iMaxONOFFCycPerHourNumericNum   = 19 ! N19, \field Maximum Cycling Rate
      iHPTimeConstantNumericNum       = 20 ! N20, \field Heat Pump Time Constant
      iOnCyclePowerFracNumericNum     = 21 ! N21, \field Fraction of On-Cycle Power Use
      iFanDelayTimeNumericNum         = 22 ! N22, \field Heat Pump Fan Delay Time
      iAncillaryOnPowerNumericNum     = 23 ! N23, \field Ancilliary On-Cycle Electric Power
      iAncillaryOffPowerNumericNum    = 24 ! N24, \field Ancilliary Off-Cycle Electric Power
      iDesignHRWaterVolFlowNumericNum = 25 ! N25, \field Design Heat Recovery Water Flow Rate
      iMaxHROutletWaterTempNumericNum = 26 ! N26, \field Maximum Temperature for Heat Recovery
      iHRWaterInletNodeAlphaNum       = 24 ! A24, \field Heat Recovery Water Inlet Node Name
      iHRWaterOutletNodeAlphaNum      = 25 ! A25, \field Heat Recovery Water Outlet Node Name

      iDesignSpecMSHPTypeAlphaNum     = 26 ! A26, \field design Specification Multispeed Heat Pump Object Type
      iDesignSpecMSHPNameAlphaNum     = 27 ! A27; \field design Specification Multispeed Heat Pump Object Name


      ! Get the data for the Unitary System
      CurrentModuleObject='AirloopHVAC:UnitarySystem'
      DO UnitarySysNum = 1,  NumUnitarySystem

        FanInletNode          = 0
        FanOutletNode         = 0
        FanVolFlowRate        = 0.0d0
        CoolingCoilInletNode  = 0
        CoolingCoilOutletNode = 0
        HeatingCoilInletNode  = 0
        HeatingCoilOutletNode = 0
        SupHeatCoilInletNode  = 0
        SupHeatCoilOutletNode = 0

        CurrentModuleObject  = 'AirLoopHVAC:UnitarySystem'
        UnitarySystem(UnitarySysNum)%UnitarySystemType = CurrentModuleObject
        UnitarySystem(UnitarySysNum)%UnitarySystemType_Num = UnitarySystem_AnyCoilType

        CALL GetObjectItem(TRIM(CurrentModuleObject),UnitarySysNum,Alphas,NumAlphas,Numbers,NumNumbers,IOStatus, &
                           NumBlank=lNumericBlanks,AlphaBlank=lAlphaBlanks, &
                           AlphaFieldNames=cAlphaFields,NumericFieldNames=cNumericFields)

        IsNotOK=.FALSE.
        IsBlank=.FALSE.
        CALL VerifyName(Alphas(iNameAlphaNum),UnitarySystem%Name,UnitarySysNum-1, &
                        IsNotOK,IsBlank,TRIM(CurrentModuleObject)//' Name')
        IF (IsNotOK) THEN
          ErrorsFound=.TRUE.
          IF (IsBlank) Alphas(iNameAlphaNum)='xxxxx'
        END IF

        UnitarySystem(UnitarySysNum)%Name            = Alphas(iNameAlphaNum)

        IF(SameString(Alphas(iControlTypeAlphaNum),'Load'))THEN
          UnitarySystem(UnitarySysNum)%ControlType = LoadBased
        ELSEIF(SameString(Alphas(iControlTypeAlphaNum),'SetPoint'))THEN
          UnitarySystem(UnitarySysNum)%ControlType = SetPointBased
        ELSE
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iControlTypeAlphaNum))//' = '//TRIM(Alphas(iControlTypeAlphaNum)))
          ErrorsFound=.TRUE.
        END IF

         !Get the Controlling Zone or Location of the Thermostat
        UnitarySystem(UnitarySysNum)%ControlZoneNum = FindItemInList(Alphas(iControlZoneAlphaNum),Zone%Name,NumOfZones)

        IF(.NOT. lAlphaBlanks(iDehumidControlAlphaNum))THEN
          IF (SameString(Alphas(iDehumidControlAlphaNum),'None') .OR. &
              SameString(Alphas(iDehumidControlAlphaNum),'Multimode') .OR. &
              SameString(Alphas(iDehumidControlAlphaNum),'CoolReheat'))THEN
            AirNodeFound=.FALSE.
            IF(SameString(Alphas(iDehumidControlAlphaNum),'Multimode'))THEN
              UnitarySystem(UnitarySysNum)%DehumidControlType_Num = DehumidControl_Multimode
              UnitarySystem(UnitarySysNum)%Humidistat = .TRUE.
            END IF
            IF(SameString(Alphas(iDehumidControlAlphaNum),'CoolReheat'))THEN
              UnitarySystem(UnitarySysNum)%DehumidControlType_Num = DehumidControl_CoolReheat
              UnitarySystem(UnitarySysNum)%Humidistat = .TRUE.
              IF(lAlphaBlanks(iSuppHeatCoilNameAlphaNum))THEN
              END IF
            END IF
            IF(SameString(Alphas(iDehumidControlAlphaNum),'None'))THEN
              UnitarySystem(UnitarySysNum)%DehumidControlType_Num = DehumidControl_None
              UnitarySystem(UnitarySysNum)%Humidistat = .FALSE.
            END IF
            IF(UnitarySystem(UnitarySysNum)%Humidistat .AND. &
               UnitarySystem(UnitarySysNum)%ControlType == LoadBased)THEN
              DO HstatZoneNum = 1, NumHumidityControlZones
                IF(HumidityControlZone(HstatZoneNum)%ActualZoneNum .NE. UnitarySystem(UnitarySysNum)%ControlZoneNum)CYCLE
                AirNodeFound=.TRUE.
              END DO
              IF (.not. AirNodeFound) THEN
                CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                CALL ShowContinueError('Did not find Air Node (Zone with Humidistat).')
                CALL ShowContinueError('specified '//TRIM(cAlphaFields(iControlZoneAlphaNum))//' = '// &
                                       TRIM(Alphas(iControlZoneAlphaNum)))
                ErrorsFound=.TRUE.
             END IF
            END IF
          ELSE ! invalid input
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iDehumidControlAlphaNum))//' = '// &
                                   TRIM(Alphas(iDehumidControlAlphaNum)))
            UnitarySystem(UnitarySysNum)%Humidistat = .FALSE.
            ErrorsFound=.TRUE.
          END IF
        END IF

        IF (lAlphaBlanks(iSysAvailSchedAlphaNum)) THEN
          UnitarySystem(UnitarySysNum)%SysAvailSchedPtr        = ScheduleAlwaysOn
        ELSE
          UnitarySystem(UnitarySysNum)%SysAvailSchedPtr        = GetScheduleIndex(Alphas(iSysAvailSchedAlphaNum))
          IF (UnitarySystem(UnitarySysNum)%SysAvailSchedPtr == 0) THEN
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iSysAvailSchedAlphaNum))//' = '// &
                                   TRIM(Alphas(iSysAvailSchedAlphaNum)))
            ErrorsFound=.TRUE.
          END IF
        END IF

        UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum = &
            GetOnlySingleNode(Alphas(iAirInletNodeNameAlphaNum),ErrorsFound,CurrentModuleObject,Alphas(iNameAlphaNum), &
                     NodeType_Air,NodeConnectionType_Inlet,1,ObjectIsParent)
        UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum = &
            GetOnlySingleNode(Alphas(iAirOutletNodeNameAlphaNum),ErrorsFound,CurrentModuleObject,Alphas(iNameAlphaNum), &
                     NodeType_Air,NodeConnectionType_Outlet,1,ObjectIsParent)

         !Get fan data
        FanType = Alphas(iFanTypeAlphaNum)
        FanName = Alphas(iFanNameAlphaNum)

        IF(.NOT. lAlphaBlanks(iFanTypeAlphaNum))THEN
          IsNotOK=.FALSE.
          CALL GetFanType(FanName, UnitarySystem(UnitarySysNum)%FanType_Num, IsNotOK,   &
               CurrentModuleObject,Alphas(iNameAlphaNum))
          IF (IsNotOK) THEN
            ErrorsFound=.TRUE.
          END IF
          UnitarySystem(UnitarySysNum)%FanExists = .TRUE.
        END IF

        IF (UnitarySystem(UnitarySysNum)%FanType_Num == FanType_SimpleOnOff .OR. &
            UnitarySystem(UnitarySysNum)%FanType_Num == FanType_SimpleConstVolume .OR. &
            UnitarySystem(UnitarySysNum)%FanType_Num == FanType_SimpleVAV)THEN
          IsNotOK=.FALSE.
          CALL ValidateComponent(FanType,FanName,IsNotOK,TRIM(CurrentModuleObject))
          IF (IsNotOK) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.

          ELSE ! mine data from fan object

            ! Get the fan index
            ErrFlag=.FALSE.
            CALL GetFanIndex(FanName, UnitarySystem(UnitarySysNum)%FanIndex, ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get the Design Fan Volume Flow Rate
            ErrFlag=.FALSE.
            FanVolFlowRate = GetFanDesignVolumeFlowRate(FanType,FanName,ErrFlag)
            IF(FanVolFlowRate == Autosize)UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            UnitarySystem(UnitarySysNum)%ActualFanVolFlowRate = FanVolFlowRate
            UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = FanVolFlowRate
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get the Fan Inlet Node
            ErrFlag=.FALSE.
            FanInletNode = GetFanInletNode(FanType,FanName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get the Fan Outlet Node
            ErrFlag=.FALSE.
            FanOutletNode = GetFanOutletNode(FanType,FanName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get the fan's availability schedule
            ErrFlag=.FALSE.
            UnitarySystem(UnitarySysNum)%FanAvailSchedPtr = GetFanAvailSchPtr(FanType,FanName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

          END IF ! IF (IsNotOK) THEN

        ELSEIF(UnitarySystem(UnitarySysNum)%FanExists)THEN
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iFanTypeAlphaNum))//' = '//TRIM(Alphas(iFanTypeAlphaNum)))
          ErrorsFound=.TRUE.
        END IF ! IF (UnitarySystem(UnitarySysNum)%FanType_Num...

        ! Add fan to component sets array
        IF(UnitarySystem(UnitarySysNum)%FanExists)CALL SetUpCompSets(CurrentModuleObject, Alphas(iNameAlphaNum), &
                           Alphas(iFanTypeAlphaNum),Alphas(iFanNameAlphaNum),NodeID(FanInletNode),NodeID(FanOutletNode))

        IF (SameString(Alphas(iFanPlaceAlphaNum),'BlowThrough') )      &
               UnitarySystem(UnitarySysNum)%FanPlace = BlowThru
        IF (SameString(Alphas(iFanPlaceAlphaNum),'DrawThrough') )      &
              UnitarySystem(UnitarySysNum)%FanPlace = DrawThru
        IF (UnitarySystem(UnitarySysNum)%FanPlace .EQ.0 .AND. UnitarySystem(UnitarySysNum)%FanExists) THEN
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iFanPlaceAlphaNum))//' = '//TRIM(Alphas(iFanPlaceAlphaNum)))
          ErrorsFound = .TRUE.
        END IF

        UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr     = GetScheduleIndex(Alphas(iFanSchedAlphaNum))
        IF (.NOT. lAlphaBlanks(iFanSchedAlphaNum) .AND. UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr == 0) THEN
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iFanSchedAlphaNum))//' = '//TRIM(Alphas(iFanSchedAlphaNum)))
          ErrorsFound=.TRUE.
        ELSEIF (lAlphaBlanks(iFanSchedAlphaNum)) THEN
          IF(UnitarySystem(UnitarySysNum)%ControlType == SetPointBased)THEN
            ! Fan operating mode must be constant fan so that the coil outlet temp is proportional to PLR
            ! Cycling fan always outputs the full load outlet air temp so should not be used with set point based control
            UnitarySystem(UnitarySysNum)%FanOpMode = ContFanCycCoil
          ELSE
            UnitarySystem(UnitarySysNum)%FanOpMode = CycFanCycCoil
            IF(UnitarySystem(UnitarySysNum)%FanType_Num /= FanType_SimpleOnOff)THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError(TRIM(cAlphaFields(iFanTypeAlphaNum))//' = '//TRIM(Alphas(iFanTypeAlphaNum)))
              CALL ShowContinueError('Fan type must be Fan:OnOff when '//  &
                                     TRIM(cAlphaFields(iFanSchedAlphaNum))//' = Blank.')
              ErrorsFound=.TRUE.
            END IF
          END IF
        ELSE IF(.NOT. lAlphaBlanks(iFanSchedAlphaNum) .AND. UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr .GT. 0 .AND. &
                UnitarySystem(UnitarySysNum)%ControlType == SetPointBased)THEN
          IF (.NOT. CheckScheduleValueMinMax(UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr,'>',0.0d0,'<=',1.0d0)) THEN
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('For '//TRIM(cAlphaFields(iFanTypeAlphaNum))//' = '//TRIM(Alphas(iFanTypeAlphaNum)))
            CALL ShowContinueError('Fan operating mode must be continuous (fan operating mode schedule values > 0).')
            CALL ShowContinueError('Error found in '//TRIM(cAlphaFields(iFanSchedAlphaNum))//' = '//TRIM(Alphas(iFanSchedAlphaNum)))
            CALL ShowContinueError('...schedule values must be (>0., <=1.)')
            ErrorsFound=.TRUE.
          END IF
        END IF

        ! Check fan's schedule for cycling fan operation IF constant volume fan is used
        IF(UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr .GT. 0 .AND. &
           UnitarySystem(UnitarySysNum)%FanType_Num == FanType_SimpleConstVolume)THEN
          IF (.NOT. CheckScheduleValueMinMax(UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr,'>',0.0d0,'<=',1.0d0)) THEN
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('For '//TRIM(cAlphaFields(iFanTypeAlphaNum))//' = '//TRIM(Alphas(iFanTypeAlphaNum)))
            CALL ShowContinueError('Fan operating mode must be continuous (fan operating mode schedule values > 0).')
            CALL ShowContinueError('Error found in '//TRIM(cAlphaFields(iFanSchedAlphaNum))//' = '// &
                                   TRIM(Alphas(iFanSchedAlphaNum)))
            CALL ShowContinueError('...schedule values must be (>0., <=1.)')
            ErrorsFound=.TRUE.
          END IF
        END IF

            !Get coil data
        HeatingCoilType = Alphas(iHeatingCoilTypeAlphaNum)
        HeatingCoilName = Alphas(iHeatingCoilNameAlphaNum)
        IF(NumNumbers .GT. (iHeatingCoilSizeRatioNumericNum-1))THEN
          HeatingSizingRatio = Numbers(iHeatingCoilSizeRatioNumericNum)
          UnitarySystem(UnitarySysNum)%HeatingSizingRatio = HeatingSizingRatio
        ELSE
          HeatingSizingRatio = 1.0d0
        END IF
        HeatingCoilPLFCurveIndex = 0
        UnitarySystem(UnitarySysNum)%HeatingCoilName = HeatingCoilName
        IF(.NOT. lAlphaBlanks(iHeatingCoilTypeAlphaNum))THEN
          UnitarySystem(UnitarySysNum)%HeatCoilExists = .TRUE.
          PrintMessage = .FALSE.
        END IF

        IF (SameString(HeatingCoilType, 'Coil:Heating:DX:VariableSpeed') )THEN
          UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = Coil_HeatingAirToAirVariableSpeed
        ELSEIF (SameString(HeatingCoilType,'Coil:Heating:DX:MultiSpeed')) THEN
          UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = CoilDX_MultiSpeedHeating
        ELSEIF (SameString(HeatingCoilType,'Coil:Heating:Water')) THEN
          UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = Coil_HeatingWater
        ELSEIF (SameString(HeatingCoilType,'Coil:Heating:Steam')) THEN
          UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = Coil_HeatingSteam
        ELSEIF (SameString(HeatingCoilType,'Coil:Heating:WaterToAirHeatPump:EquationFit')) THEN
            UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = Coil_HeatingWaterToAirHPSimple
        ELSEIF (SameString(HeatingCoilType,'Coil:Heating:WaterToAirHeatPump:ParameterEstimation')) THEN
            UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = Coil_HeatingWaterToAirHP
        ELSEIF (SameString(HeatingCoilType,'Coil:Heating:WaterToAirHeatPump:VariableSpeedEquationFit')) THEN
            UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = Coil_HeatingWaterToAirHPVSEquationFit
        ELSEIF (SameString(HeatingCoilType,'Coil:Heating:Electric:MultiStage')) THEN
            UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = Coil_HeatingElectric_MultiStage
        ELSEIF (SameString(HeatingCoilType,'Coil:Heating:Gas:MultiStage')) THEN
            UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = Coil_HeatingGas_MultiStage
        ELSEIF (SameString(HeatingCoilType,'Coil:Heating:Gas')          .OR. &
                SameString(HeatingCoilType,'Coil:Heating:Electric')     .OR. &
                SameString(HeatingCoilType,'Coil:Heating:Desuperheater')) THEN
            UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = GetHeatingCoilTypeNum(HeatingCoilType,HeatingCoilName,ErrFlag)
        ELSE IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
          UnitarySystem(UnitarySysNum)%HeatingCoilType_Num = &
                 GetDXCoilTypeNum(HeatingCoilType,HeatingCoilName,ErrFlag,PrintMessage)
        END IF

        IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)  THEN

          UnitarySystem(UnitarySysNum)%DXHeatingCoil = .TRUE.
          ErrFlag = .FALSE.

          CALL ValidateComponent(HeatingCoilType,HeatingCoilName,IsNotOK,  &
                                 TRIM(CurrentModuleObject))
          IF (IsNotOK) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.

          ELSE ! mine data from DX heating coil

            ! Get DX heating coil index
            CALL GetDXCoilIndex(HeatingCoilName,UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            UnitarySystem(UnitarySysNum)%HeatingCoilAvailSchPtr = GetDXCoilAvailSchPtr(HeatingCoilType,HeatingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            ! Get DX heating coil capacity
            UnitarySystem(UnitarySysNum)%DesignHeatingCapacity =    &
               GetDXCoilCapacity(HeatingCoilType,HeatingCoilName,ErrFlag)
            IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            ! Get DX coil air flow rate.
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow   = GetDXCoilAirFlow(HeatingCoilType,HeatingCoilName,ErrFlag)
            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            ! Get the Heating Coil Nodes
            HeatingCoilInletNode = GetDXCoilInletNode(HeatingCoilType,HeatingCoilName,ErrFlag)
            HeatingCoilOutletNode = GetDXCoilOutletNode(HeatingCoilType,HeatingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            CALL SetDXCoolingCoilData(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrorsFound, &
                                      HeatSizeRatio=HeatingSizingRatio)
          END IF

        ELSEIF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit) THEN

          UnitarySystem(UnitarySysNum)%DXHeatingCoil = .TRUE.

          CALL ValidateComponent(HeatingCoilType,HeatingCoilName,IsNotOK,  &
                                 TRIM(CurrentModuleObject))
          IF (IsNotOK) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.
          ELSE

            UnitarySystem(UnitarySysNum)%HeatingCoilIndex = GetCoilIndexVariableSpeed(HeatingCoilType, HeatingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            UnitarySystem(UnitarySysNum)%NumOfSpeedHeating = GetVSCoilNumOfSpeeds(HeatingCoilName,ErrFlag)

            UnitarySystem(UnitarySysNum)%HeatingCoilAvailSchPtr = ScheduleAlwaysOn

            HeatingCoilInletNode=GetCoilInletNodeVariableSpeed(HeatingCoilType, HeatingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            HeatingCoilOutletNode=GetCoilOutletNodeVariableSpeed(HeatingCoilType, HeatingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

          END IF
        ELSEIF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating) THEN
          UnitarySystem(UnitarySysNum)%DXHeatingCoil = .TRUE.
          ErrFlag = .FALSE.
          CALL GetDXCoilIndex(HeatingCoilName,UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                              ErrFlag, TRIM(HeatingCoilType))
          IF(ErrFlag) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.true.
            ErrFlag = .FALSE.
          END IF

          UnitarySystem(UnitarySysNum)%HeatingCoilAvailSchPtr = GetDXCoilAvailSchPtr(HeatingCoilType,HeatingCoilName,ErrFlag)

          HeatingCoilInletNode = GetDXCoilInletNode(HeatingCoilType,HeatingCoilName,ErrFlag)
          IF(ErrFlag)THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound = .TRUE.
            ErrFlag = .FALSE.
          END IF
          HeatingCoilOutletNode = GetDXCoilOutletNode(HeatingCoilType,HeatingCoilName,ErrFlag)
          IF(ErrFlag)THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound = .TRUE.
            ErrFlag = .FALSE.
          END IF

!            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize) &
!                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
!            IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize) &
!                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

        ELSEIF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingElectric_MultiStage .OR. &
                UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingGas_MultiStage ) THEN

          ErrFlag = .FALSE.
          CALL GetHeatingCoilIndex(HeatingCoilName,UnitarySystem(UnitarySysNum)%HeatingCoilIndex, ErrFlag)
          IF (ErrFlag) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.
            ErrFlag = .FALSE.
          END IF
          HeatingCoilInletNode = GetHeatingCoilInletNode(HeatingCoilType,HeatingCoilName,ErrFlag)
          IF (ErrFlag) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.
            ErrFlag = .FALSE.
          END IF
          HeatingCoilOutletNode = GetHeatingCoilOutletNode(HeatingCoilType,HeatingCoilName,ErrFlag)
          IF (ErrFlag) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.
            ErrFlag = .FALSE.
          END IF

          UnitarySystem(UnitarySysNum)%DesignHeatingCapacity =    &
            GetHeatingCoilCapacity(HeatingCoilType,HeatingCoilName,ErrFlag)

!            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize) &
!                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
          IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize) &
               UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

        ELSEIF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingGas          .OR. &
                UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingElectric     .OR. &
                UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingDesuperheater) THEN
            ErrFlag = .FALSE.
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            ELSE

              CALL ValidateComponent(HeatingCoilType,HeatingCoilName,IsNotOK,  &
                                     TRIM(CurrentModuleObject))
              IF (IsNotOK) THEN
                CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                ErrorsFound=.TRUE.

              ELSE ! mine data from heating coil

                ! Get heating coil index
                ErrFlag=.FALSE.
                CALL GetHeatingCoilIndex(HeatingCoilName,UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFlag)
                IF (ErrFlag) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound=.TRUE.
                  ErrFlag=.FALSE.
                END IF

                ! Get the design heating capacity
                UnitarySystem(UnitarySysNum)%DesignHeatingCapacity =   &
                   GetHeatingCoilCapacity(HeatingCoilType,HeatingCoilName,ErrFlag)
                IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize) &
                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
                IF (ErrFlag) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound=.TRUE.
                  ErrFlag=.FALSE.
                END IF

                UnitarySystem(UnitarySysNum)%HeatingCoilAvailSchPtr = &
                       GetCoilAvailScheduleIndex(HeatingCoilType,HeatingCoilName,ErrFlag)

                ! Get the Heating Coil Inlet Node
                HeatingCoilInletNode = &
                       GetHeatingCoilInletNode(HeatingCoilType,HeatingCoilName,ErrFlag)
                IF (ErrFlag) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound=.TRUE.
                  ErrFlag=.FALSE.
                END IF

                ! Get the Heating Coil Outlet Node
                HeatingCoilOutletNode = &
                       GetHeatingCoilOutletNode(HeatingCoilType,HeatingCoilName,ErrFlag)
                IF (ErrFlag) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound=.TRUE.
                  ErrFlag=.FALSE.
                END IF

                ! Get the Heating Coil PLF Curve Index
                HeatingCoilPLFCurveIndex = &
                       GetHeatingCoilPLFCurveIndex(HeatingCoilType,HeatingCoilName,ErrFlag)
                IF (ErrFlag) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound=.TRUE.
                  ErrFlag=.FALSE.
                END IF
               ! These heating coil types do not have an air flow input field
               IF(NumNumbers < iMaxHeatAirVolFlowNumericNum)THEN
                 UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
               END IF
              END IF ! IF (IsNotOK) THEN

            END IF

        ELSEIF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWater) THEN
            CALL ValidateComponent(HeatingCoilType,HeatingCoilName,IsNotOK,TRIM(CurrentModuleObject))
            IF (IsNotOK) THEN
                CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                ErrorsFound=.TRUE.
            ELSE ! mine data from heating coil object

                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%HeatingCoilAvailSchPtr = &
                       GetWaterCoilAvailScheduleIndex(HeatingCoilType,HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                UnitarySystem(UnitarySysNum)%HeatingCoilIndex = GetWaterCoilIndex('COIL:HEATING:WATER',HeatingCoilName,ErrFlag)
                IF (UnitarySystem(UnitarySysNum)%HeatingCoilIndex .EQ. 0) THEN
                  CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iHeatingCoilNameAlphaNum))//' = ' &
                                  //TRIM(HeatingCoilName))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil water Inlet or control Node number
                UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode = &
                    GetCoilWaterInletNode('Coil:Heating:Water',HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil hot water max volume flow rate
                UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                                           HeatingCoilName,ErrFlag)
                IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow == Autosize) &
                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil Inlet Node
                HeatingCoilInletNode =  GetWaterCoilInletNode('Coil:Heating:Water',HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil Outlet Node
                HeatingCoilOutletNode = GetWaterCoilOutletNode('Coil:Heating:Water',HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

            END IF

        ELSEIF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingSteam) THEN
            CALL ValidateComponent(HeatingCoilType,HeatingCoilName,IsNotOK,TRIM(CurrentModuleObject))
            IF (IsNotOK) THEN
                CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                ErrorsFound=.TRUE.
            ELSE ! mine data from heating coil object

                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%HeatingCoilAvailSchPtr = &
                       GetSteamCoilAvailScheduleIndex(HeatingCoilType,HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                UnitarySystem(UnitarySysNum)%HeatingCoilIndex = GetSteamCoilIndex('COIL:HEATING:STEAM',HeatingCoilName,ErrFlag)
                IF (UnitarySystem(UnitarySysNum)%HeatingCoilIndex .EQ. 0) THEN
                  CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iHeatingCoilNameAlphaNum))//' = ' &
                                  //TRIM(HeatingCoilName))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil steam inlet node number
                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode = &
                    GetSteamCoilSteamInletNode('Coil:Heating:Steam',HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil steam max volume flow rate
                UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow = &
                    GetCoilMaxSteamFlowRate(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,ErrFlag)
                IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow == Autosize) &
                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

                IF (UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow .GT. 0.0d0)THEN
                  SteamIndex = 0      ! Function GetSatDensityRefrig will look up steam index if 0 is passed
                  SteamDensity=GetSatDensityRefrig("STEAM",TempSteamIn,1.0d0,SteamIndex,'GetAirLoopHVACHeatCoolInput')
                  UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow = &
                                UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow * SteamDensity
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil Inlet Node
                ErrFlag = .FALSE.
                HeatingCoilInletNode = &
                         GetSteamCoilAirInletNode(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil Outlet Node
                HeatingCoilOutletNode = &
                         GetSteamCoilAirOutletNode(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

               IF(NumNumbers < iMaxHeatAirVolFlowNumericNum)THEN
                 UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Autosize
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
               END IF

            END IF

        ELSEIF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple) THEN
            UnitarySystem(UnitarySysNum)%DXHeatingCoil = .TRUE.
            CALL ValidateComponent(HeatingCoilType,HeatingCoilName,IsNotOK,TRIM(CurrentModuleObject))
            IF (IsNotOK) THEN
                CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                ErrorsFound=.TRUE.
            ELSE ! mine data from heating coil object

                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%HeatingCoilAvailSchPtr = ScheduleAlwaysOn
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                UnitarySystem(UnitarySysNum)%HeatingCoilIndex = GetWtoAHPSimpleCoilIndex(HeatingCoilType,HeatingCoilName,ErrFlag)
                IF (UnitarySystem(UnitarySysNum)%HeatingCoilIndex .EQ. 0) THEN
                  CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iHeatingCoilNameAlphaNum))//' = ' &
                                  //TRIM(HeatingCoilName))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil Inlet Node
                ErrFlag = .FALSE.
                HeatingCoilInletNode = GetWtoAHPSimpleCoilInletNode(HeatingCoilType, HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil Outlet Node
                HeatingCoilOutletNode = GetWtoAHPSimpleCoilOutletNode(HeatingCoilType, HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

!                IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow == Autosize) &
!                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
!                IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize) &
!                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
!                IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow == Autosize) &
!                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF

        ELSEIF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHP) THEN
            UnitarySystem(UnitarySysNum)%DXHeatingCoil = .TRUE.
            CALL ValidateComponent(HeatingCoilType,HeatingCoilName,IsNotOK,TRIM(CurrentModuleObject))
            IF (IsNotOK) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                ErrorsFound=.TRUE.
            ELSE ! mine data from heating coil object

                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%HeatingCoilAvailSchPtr = ScheduleAlwaysOn
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                UnitarySystem(UnitarySysNum)%HeatingCoilIndex =  GetWtoAHPCoilIndex(HeatingCoilType, HeatingCoilName,ErrFlag)
                IF (UnitarySystem(UnitarySysNum)%HeatingCoilIndex .EQ. 0) THEN
                  CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iHeatingCoilNameAlphaNum))//' = ' &
                                  //TRIM(HeatingCoilName))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil Inlet Node
                ErrFlag = .FALSE.
                HeatingCoilInletNode = GetWtoAHPCoilInletNode(HeatingCoilType, HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Heating Coil Outlet Node
                HeatingCoilOutletNode = GetWtoAHPCoilOutletNode(HeatingCoilType, HeatingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

!                IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow == Autosize) &
!                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
!                IF(UnitarySystem(UnitarySysNum)%DesignHeatingCapacity == Autosize) &
!                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
!                IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow == Autosize) &
!                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            END IF

        ELSEIF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iHeatingCoilTypeAlphaNum))//' = '// &
                                 TRIM(Alphas(iHeatingCoilTypeAlphaNum)))
          ErrorsFound=.TRUE.
        END IF ! IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingGas .OR. &, etc.

        IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
           UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingElectric_MultiStage .OR. &
           UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingGas_MultiStage) THEN
          UnitarySystem(UnitarySysNum)%MultiSpeedHeatingCoil = .TRUE.
        ELSEIF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
           UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed ) THEN
          UnitarySystem(UnitarySysNum)%VarSpeedHeatingCoil = .TRUE.
        END IF

        ! coil outlet node set point has priority, IF not exist, then use system outlet node
        IF(NodeHasSPMCtrlVarType(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum, iCtrlVarType_Temp)) &
            UnitarySystem(UnitarySysNum)%SystemHeatControlNodeNum = UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum
        IF(NodeHasSPMCtrlVarType(HeatingCoilOutletNode, iCtrlVarType_Temp)) &
          UnitarySystem(UnitarySysNum)%SystemHeatControlNodeNum = HeatingCoilOutletNode

        UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum  = HeatingCoilInletNode
        UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum = HeatingCoilOutletNode
        UnitarySystem(UnitarySysNum)%HeatingCoilName       = HeatingCoilName

        ! Add heating coil to component sets array
        IF(UnitarySystem(UnitarySysNum)%HeatCoilExists) THEN
          IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num .NE. CoilDX_MultiSpeedHeating) THEN
            CALL SetUpCompSets(CurrentModuleObject, Alphas(iNameAlphaNum), &
                               Alphas(iHeatingCoilTypeAlphaNum),Alphas(iHeatingCoilNameAlphaNum), &
                               NodeID(HeatingCoilInletNode), NodeID(HeatingCoilOutletNode))
          ELSE
            CALL SetUpCompSets(CurrentModuleObject, Alphas(iNameAlphaNum), &
                               Alphas(iHeatingCoilTypeAlphaNum),Alphas(iHeatingCoilNameAlphaNum), &
                               'UNDEFINED', 'UNDEFINED')
          END IF
        END IF
        ! Get Cooling Coil Information IF available
        CoolingCoilType = Alphas(iCoolingCoilTypeAlphaNum)
        CoolingCoilName = Alphas(iCoolingCoilNameAlphaNum)
        IF(.NOT. lAlphaBlanks(iCoolingCoilTypeAlphaNum))THEN
          UnitarySystem(UnitarySysNum)%CoolCoilExists = .TRUE.

!       Find the type of coil. do not print message since this may not be the correct coil type.
        ErrFlag = .FALSE.
        IF (SameString(CoolingCoilType, 'Coil:Cooling:DX:VariableSpeed') )THEN
          UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = Coil_CoolingAirToAirVariableSpeed
        ELSEIF (SameString(CoolingCoilType,'Coil:Cooling:DX:MultiSpeed')) THEN
          UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = CoilDX_MultiSpeedCooling
        ELSEIF (SameString(CoolingCoilType,'Coil:Cooling:Water')) THEN
          UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = Coil_CoolingWater
        ELSEIF (SameString(CoolingCoilType,'Coil:Cooling:Water:DetailedGeometry')) THEN
          UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = Coil_CoolingWaterDetailed
        ELSEIF (SameString(CoolingCoilType,'Coil:Cooling:DX:TwoStageWithHumidityControlMode')) THEN
          UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = CoilDX_CoolingTwoStageWHumControl
        ELSEIF (SameString(CoolingCoilType,'CoilSystem:Cooling:DX:HeatExchangerAssisted')) THEN
          UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = &
                 GetHXAssistedCoilTypeNum(CoolingCoilType,CoolingCoilName,ErrFlag,PrintMessage)
        ELSEIF (SameString(CoolingCoilType,'CoilSystem:Cooling:Water:HeatExchangerAssisted')) THEN
          ! why use a mining function, why not just set it using the integer representation?
          UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = &
                 GetHXAssistedCoilTypeNum(CoolingCoilType,CoolingCoilName,ErrFlag,PrintMessage)
        ELSEIF (SameString(CoolingCoilType,'Coil:Cooling:WaterToAirHeatPump:EquationFit')) THEN
            UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = Coil_CoolingWaterToAirHPSimple
        ELSEIF (SameString(CoolingCoilType,'Coil:Cooling:WaterToAirHeatPump:ParameterEstimation')) THEN
            UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = Coil_CoolingWaterToAirHP
        ELSEIF (SameString(CoolingCoilType,'Coil:Cooling:WaterToAirHeatPump:VariableSpeedEquationFit')) THEN
            UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = Coil_CoolingWaterToAirHPVSEquationFit
        ELSEIF (SameString(CoolingCoilType,'Coil:Cooling:DX:SingleSpeed')) THEN
          UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = &
                 GetDXCoilTypeNum(CoolingCoilType,CoolingCoilName,ErrFlag,PrintMessage)
        ELSEIF (SameString(CoolingCoilType,'Coil:Cooling:DX:TwoSpeed')) THEN
          UnitarySystem(UnitarySysNum)%CoolingCoilType_Num = &
                 GetDXCoilTypeNum(CoolingCoilType,CoolingCoilName,ErrFlag,PrintMessage)
        ELSE
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iCoolingCoilTypeAlphaNum))//' = '// &
                                 TRIM(Alphas(iCoolingCoilTypeAlphaNum)))
        END IF

        IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingSingleSpeed .OR. &
            UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoSpeed)THEN
          CALL ValidateComponent(CoolingCoilType,CoolingCoilName,IsNotOK,  &
                                 TRIM(CurrentModuleObject))
          IF (IsNotOK) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.

          ELSE ! mine data from DX cooling coil

            IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoSpeed) &
                 UnitarySystem(UnitarySysNum)%NumOfSpeedCooling = 2

            ! Get DX cooling coil index
            CALL GetDXCoilIndex(CoolingCoilName,UnitarySystem(UnitarySysNum)%CoolingCoilIndex,IsNotOK)
            IF(IsNotOK)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr = GetDXCoilAvailSchPtr(CoolingCoilType,CoolingCoilName,ErrFlag)

            ! Get DX cooling coil capacity
            ErrFlag = .FALSE.
            UnitarySystem(UnitarySysNum)%DesignCoolingCapacity =    &
                 GetDXCoilCapacity(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(UnitarySystem(UnitarySysNum)%DesignCoolingCapacity == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get DX coil air flow rate. Latter fields will overwrite this IF input field is present
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow   = GetDXCoilAirFlow(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            ! Get the Cooling Coil Nodes
            ErrFlag=.FALSE.
            CoolingCoilInletNode = GetDXCoilInletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            CoolingCoilOutletNode = GetDXCoilOutletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get Outdoor condenser node from DX coil object
            ErrFlag=.FALSE.
            UnitarySystem(UnitarySysNum)%CondenserNodeNum = &
                    GetDXCoilCondenserInletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            IF(UnitarySystem(UnitarySysNum)%FanExists)THEN
              ErrFlag = .FALSE.
              CALL GetFanIndex(FanName,FanIndex,ErrFlag,CurrentModuleObject)
              CALL SetDXCoolingCoilData(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrFlag, &
                                        SupplyFanName=FanName)
              CALL SetDXCoolingCoilData(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrFlag, &
                                        SupplyFanIndex=FanIndex)
              IF (ErrFlag) THEN
                CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                ErrorsFound=.TRUE.
              END IF
            END IF
            IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
              IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
                UnitarySystem(UnitarySysNum)%HeatPump = .TRUE.
              END IF
            END IF

          END IF ! IF (IsNotOK) THEN

          ! Push heating coil PLF curve index to DX coil
          IF(HeatingCoilPLFCurveIndex .GT. 0)THEN
            CALL SetDXCoolingCoilData(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrorsFound, &
                                      HeatingCoilPLFCurvePTR=HeatingCoilPLFCurveIndex)
          END IF

        ELSEIF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoStageWHumControl)THEN
          CALL ValidateComponent(CoolingCoilType,CoolingCoilName,IsNotOK,  &
                                 TRIM(CurrentModuleObject))
          IF (IsNotOK) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.

          ELSE ! mine data from DX cooling coil

            ! Get DX cooling coil index
            CALL GetDXCoilIndex(CoolingCoilName,UnitarySystem(UnitarySysNum)%CoolingCoilIndex,IsNotOK)
            IF(IsNotOK)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr = GetDXCoilAvailSchPtr(CoolingCoilType,CoolingCoilName,ErrFlag)

            ! Get DX cooling coil capacity
            ErrFlag = .FALSE.
            UnitarySystem(UnitarySysNum)%DesignCoolingCapacity =    &
                 GetDXCoilCapacity(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(UnitarySystem(UnitarySysNum)%DesignCoolingCapacity == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get DX coil air flow rate. Later fields will overwrite this IF input field is present
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow   = GetDXCoilAirFlow(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            ! Get the Cooling Coil Nodes
            ErrFlag=.FALSE.
            CoolingCoilInletNode = GetDXCoilInletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            CoolingCoilOutletNode = GetDXCoilOutletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get Outdoor condenser node from DX coil object
            ErrFlag=.FALSE.
            UnitarySystem(UnitarySysNum)%CondenserNodeNum = &
                    GetDXCoilCondenserInletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

          END IF ! IF (IsNotOK) THEN

          ! Push heating coil PLF curve index to DX coil
          IF(HeatingCoilPLFCurveIndex .GT. 0)THEN
            CALL SetDXCoolingCoilData(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrorsFound, &
                                      HeatingCoilPLFCurvePTR=HeatingCoilPLFCurveIndex)
          END IF

            IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
              IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
                UnitarySystem(UnitarySysNum)%HeatPump = .TRUE.
              END IF
            END IF

        ELSEIF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingHXAssisted)THEN
          CALL ValidateComponent(CoolingCoilType,CoolingCoilName,IsNotOK,  &
                                 TRIM(CurrentModuleObject))
          IF (IsNotOK) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.

          ELSE ! mine data from heat exchanger assisted cooling coil

            ! Get DX heat exchanger assisted cooling coil index
            CALL GetHXDXCoilIndex(CoolingCoilName,UnitarySystem(UnitarySysNum)%CoolingCoilIndex,IsNotOK)
            IF(IsNotOK)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr = &
              GetDXCoilAvailSchPtr(CALLCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilIndex), &
                                   GetHXDXCoilName(CoolingCoilType,CoolingCoilName,IsNotOK),ErrFlag)

            ! Get DX cooling coil capacity
            ErrFlag = .FALSE.
            UnitarySystem(UnitarySysNum)%DesignCoolingCapacity =    &
               GetDXHXAsstdCoilCapacity(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(UnitarySystem(UnitarySysNum)%DesignCoolingCapacity == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get the Cooling Coil Nodes
            ErrFlag=.FALSE.
            CoolingCoilInletNode = GetDXHXAsstdCoilInletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            CoolingCoilOutletNode = GetDXHXAsstdCoilOutletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get Outdoor condenser node from heat exchanger assisted DX coil object
            ErrFlag=.FALSE.
            UnitarySystem(UnitarySysNum)%CondenserNodeNum = &
                GetDXCoilCondenserInletNode('COIL:COOLING:DX:SINGLESPEED', &
                GetHXDXCoilName(CoolingCoilType,CoolingCoilName,ErrFlag), ErrFlag)

            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Push heating coil PLF curve index to DX coil
            IF(HeatingCoilPLFCurveIndex .GT. 0)THEN
              ! get the actual index to the DX cooling coil object
              DXCoilIndex = GetActualDXCoilIndex(CoolingCoilType,CoolingCoilName,ErrorsFound)
              UnitarySystem(UnitarySysNum)%ActualDXCoilIndexforHXAssisted = DXCoilIndex
              CALL SetDXCoolingCoilData(DXCoilIndex,ErrorsFound, &
                                        HeatingCoilPLFCurvePTR=HeatingCoilPLFCurveIndex)
            END IF

            IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
              IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
                UnitarySystem(UnitarySysNum)%HeatPump = .TRUE.
              END IF
            END IF

          END IF ! IF (IsNotOK) THEN
        ELSEIF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilWater_CoolingHXAssisted)THEN
          CALL ValidateComponent(CoolingCoilType,CoolingCoilName,IsNotOK,  &
                                 TRIM(CurrentModuleObject))
          IF (IsNotOK) THEN
            CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.

          ELSE ! mine data from heat exchanger assisted cooling coil

            ErrFlag = .FALSE.
            ActualCoolCoilType = GetCoilObjectTypeNum(CoolingCoilType,CoolingCoilName,ErrFlag,.TRUE.)
            HXCoilName = GetHXDXCoilName(CoolingCoilType,CoolingCoilName,ErrFlag)

            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Get DX heat exchanger assisted cooling coil index
            ErrFlag = .FALSE.
            CALL GetHXDXCoilIndex(CoolingCoilName,UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ErrFlag = .FALSE.
            UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr = &
              GetWaterCoilAvailScheduleIndex(cAllCoilTypes(ActualCoolCoilType),HXCoilName,ErrFlag)
            UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow = &
              GetCoilMaxWaterFlowRate(cAllCoilTypes(ActualCoolCoilType),HXCoilName,ErrFlag)
            ! Get the Cooling Coil water Inlet Node number
            UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode = &
              GetCoilWaterInletNode(cAllCoilTypes(ActualCoolCoilType),HXCoilName,ErrFlag)
!            UnitarySystem(UnitarySysNum)%CoolCoilFluidOutletNodeNum = &
!              GetCoilWaterOutletNode(cAllCoilTypes(ActualCoolCoilType),HXCoilName,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

   ! this needs to be the coil index, not the parent
   ! CAN't do this here, we need to know the air flow rate first
!            UnitarySystem(UnitarySysNum)%DesignCoolingCapacity =    &
!               GetDXHXAsstdCoilCapacity(CoolingCoilType,CoolingCoilName,ErrFlag)
!            UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr = GetDXCoilAvailSchPtr(CoolingCoilType,CoolingCoilName,ErrFlag)

            ! Get the Cooling Coil Nodes
            ErrFlag=.FALSE.
            CoolingCoilInletNode = GetDXHXAsstdCoilInletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            CoolingCoilOutletNode = GetDXHXAsstdCoilOutletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = GetHXCoilAirFlowRate(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            UnitarySystem(UnitarySysNum)%CondenserNodeNum = 0
           IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF

            ! Push heating coil PLF curve index to DX coil
            IF(HeatingCoilPLFCurveIndex .GT. 0)THEN
              ! get the actual index to the DX cooling coil object
              DXCoilIndex = GetActualDXCoilIndex(CoolingCoilType,CoolingCoilName,ErrorsFound)
              UnitarySystem(UnitarySysNum)%ActualDXCoilIndexforHXAssisted = DXCoilIndex
              CALL SetDXCoolingCoilData(DXCoilIndex,ErrorsFound, &
                                        HeatingCoilPLFCurvePTR=HeatingCoilPLFCurveIndex)
            END IF

            IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
              IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
                UnitarySystem(UnitarySysNum)%HeatPump = .TRUE.
              END IF
            END IF

          END IF ! IF (IsNotOK) THEN
        ELSEIF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingAirToAirVariableSpeed .OR. &
                 UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHPVSEquationFit)THEN
          CALL ValidateComponent(CoolingCoilType,CoolingCoilName,IsNotOK,  &
                                 TRIM(CurrentModuleObject))
          IF (IsNotOK) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.TRUE.
          ELSE
            ErrFlag = .FALSE.
            UnitarySystem(UnitarySysNum)%CoolingCoilIndex = GetCoilIndexVariableSpeed(CoolingCoilType, &
                        CoolingCoilName,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            CoolingCoilInletNode =GetCoilInletNodeVariableSpeed(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            CoolingCoilOutletNode =GetCoilOutletNodeVariableSpeed(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            UnitarySystem(UnitarySysNum)%CondenserNodeNum = GetVSCoilCondenserInletNode(CoolingCoilName,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr = ScheduleAlwaysOn

            UnitarySystem(UnitarySysNum)%NumOfSpeedCooling = GetVSCoilNumOfSpeeds(CoolingCoilName,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
              ErrFlag = .FALSE.
            END IF

            ErrFlag=.FALSE.
            UnitarySystem(UnitarySysNum)%DesignCoolingCapacity =   &
              GetCoilCapacityVariableSpeed(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(UnitarySystem(UnitarySysNum)%DesignCoolingCapacity == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF
          END IF

          ! why was this done?
          IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingAirToAirVariableSpeed) THEN
             ErrFlag=.FALSE.
             UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow       &
                = GetCoilAirFlowRateVariableSpeed(CoolingCoilType,CoolingCoilName,ErrFlag)
             IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize) &
                  UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

             IF (ErrFlag) THEN
                CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                ErrorsFound=.TRUE.
             END IF

!            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = &
!                 MIN(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow,UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow)
!            IF(UnitarySystem(UnitarySysNum)%FanExists)THEN
!              IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow /= Autosize .AND. &
!                 UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow /= Autosize .AND. &
!                 .NOT. UnitarySystem(UnitarySysNum)%RequestAutosize)THEN
!                 UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = &
!                   MAX(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow,UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow)
!              ELSE
!                UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = Autosize
!              END IF
!            END IF
          END IF

          IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
            IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
              UnitarySystem(UnitarySysNum)%HeatPump = .TRUE.
            END IF
          END IF

        ELSEIF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling) THEN
          ErrFlag = .FALSE.
          CALL GetDXCoilIndex(CoolingCoilName,UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                              ErrFlag, TRIM(CoolingCoilType))
          IF(ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.true.
            ErrFlag = .FALSE.
          END IF

          UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr = GetDXCoilAvailSchPtr(CoolingCoilType,CoolingCoilName,ErrFlag)

          CoolingCoilInletNode = GetDXCoilInletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
          IF(ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.true.
            ErrFlag = .FALSE.
          END IF
          CoolingCoilOutletNode = GetDXCoilOutletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
          IF(ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            ErrorsFound=.true.
            ErrFlag = .FALSE.
          END IF

!          IF(UnitarySystem(UnitarySysNum)%DesignCoolingCapacity == Autosize) &
!               UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

          IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
            IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
               UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
              UnitarySystem(UnitarySysNum)%HeatPump = .TRUE.
            END IF
          END IF

        ELSEIF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWater .OR. &
                UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterDetailed) THEN

          CALL ValidateComponent(CoolingCoilType,CoolingCoilName,IsNotOK,TRIM(CurrentModuleObject))
          IF (IsNotOK) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
          ELSE ! mine data from Cooling coil object

            ErrFlag = .FALSE.
            UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr = &
                 GetWaterCoilAvailScheduleIndex(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound = .TRUE.
              ErrFlag = .FALSE.
            END IF

            UnitarySystem(UnitarySysNum)%CoolingCoilIndex = GetWaterCoilIndex(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF (UnitarySystem(UnitarySysNum)%CoolingCoilIndex .EQ. 0) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' illegal '//TRIM(cAlphaFields(iCoolingCoilNameAlphaNum))//' = ' &
                              //TRIM(HeatingCoilName))
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound = .TRUE.
              ErrFlag = .FALSE.
            END IF

            ! Get the Cooling Coil water Inlet Node number
            UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode = GetCoilWaterInletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound = .TRUE.
              ErrFlag = .FALSE.
            END IF

            InletNodeNotControlled = .TRUE.
          !  CALL CheckCoilWaterInletNode(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode,InletNodeNotControlled)
            IF(.NOT. InletNodeNotControlled)THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError(TRIM(ControllerTypes(ControllerSimple_Type))//' found for '// &
                                     TRIM(CoolingCoilType)//' = "'//TRIM(CoolingCoilName)//'."')
              CALL ShowContinueError('...water coil controllers are not used with '// &
                                      TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType))
              ErrorsFound = .TRUE.
            END IF

            ! Get the Cooling Coil chilled water max volume flow rate
            ErrFlag = .FALSE.
            UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow = GetCoilMaxWaterFlowRate(CoolingCoilType,  &
                                           CoolingCoilName,ErrFlag)
            IF(UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound = .TRUE.
              ErrFlag = .FALSE.
            END IF

            ! Get the Cooling Coil Inlet Node
            CoolingCoilInletNode =  GetWaterCoilInletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound = .TRUE.
              ErrFlag = .FALSE.
            END IF

            ! Get the Cooling Coil Outlet Node
            CoolingCoilOutletNode = GetWaterCoilOutletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
            IF(ErrFlag)THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound = .TRUE.
              ErrFlag = .FALSE.
            END IF
          END IF
        ELSEIF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHPSimple) THEN
            CALL ValidateComponent(CoolingCoilType,CoolingCoilName,IsNotOK,TRIM(CurrentModuleObject))
            IF (IsNotOK) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            ELSE ! mine data from Cooling coil object

                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr = ScheduleAlwaysOn
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                UnitarySystem(UnitarySysNum)%CoolingCoilIndex =  GetWtoAHPSimpleCoilIndex(CoolingCoilType,CoolingCoilName,ErrFlag)
                IF (UnitarySystem(UnitarySysNum)%CoolingCoilIndex .EQ. 0) THEN
                  CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iCoolingCoilNameAlphaNum))//' = ' &
                                  //TRIM(CoolingCoilName))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Cooling Coil Inlet Node
                ErrFlag = .FALSE.
                CoolingCoilInletNode = GetWtoAHPSimpleCoilInletNode(CoolingCoilType, CoolingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Cooling Coil Outlet Node
                CoolingCoilOutletNode = GetWtoAHPSimpleCoilOutletNode(CoolingCoilType, CoolingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

!                IF(UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow == Autosize) &
!                     UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            END IF

            IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
              IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
                UnitarySystem(UnitarySysNum)%HeatPump = .TRUE.
              END IF
            END IF

        ELSEIF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHP) THEN
            CALL ValidateComponent(CoolingCoilType,CoolingCoilName,IsNotOK,TRIM(CurrentModuleObject))
            IF (IsNotOK) THEN
                CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                ErrorsFound=.TRUE.
            ELSE ! mine data from Cooling coil object

                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr = ScheduleAlwaysOn
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                UnitarySystem(UnitarySysNum)%CoolingCoilIndex =  GetWtoAHPCoilIndex(CoolingCoilType, CoolingCoilName,ErrFlag)
                IF (UnitarySystem(UnitarySysNum)%CoolingCoilIndex .EQ. 0) THEN
                  CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iCoolingCoilNameAlphaNum))//' = ' &
                                  //TRIM(CoolingCoilName))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Cooling Coil Inlet Node
                ErrFlag = .FALSE.
                CoolingCoilInletNode = GetWtoAHPCoilInletNode(CoolingCoilType, CoolingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

                ! Get the Cooling Coil Outlet Node
                CoolingCoilOutletNode = GetWtoAHPCoilOutletNode(CoolingCoilType, CoolingCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                  ErrFlag = .FALSE.
                END IF

!                IF(UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow == Autosize) &
!                     UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            END IF

            IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
              IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
                 UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical)THEN
                UnitarySystem(UnitarySysNum)%HeatPump = .TRUE.
              END IF
            END IF

        ELSE ! IF(.NOT. lAlphaBlanks(16))THEN
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iCoolingCoilTypeAlphaNum))//' = '// &
                                 TRIM(Alphas(iCoolingCoilTypeAlphaNum)))
          ErrorsFound=.TRUE.
        END IF

        IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling) THEN
          UnitarySystem(UnitarySysNum)%MultiSpeedCoolingCoil = .TRUE.
        ELSEIF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHPVSEquationFit .OR. &
           UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingAirToAirVariableSpeed) THEN
          UnitarySystem(UnitarySysNum)%VarSpeedCoolingCoil = .TRUE.
        END IF

        IF(NodeHasSPMCtrlVarType(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum, iCtrlVarType_Temp)) &
            UnitarySystem(UnitarySysNum)%SystemCoolControlNodeNum = UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum
        IF(NodeHasSPMCtrlVarType(CoolingCoilOutletNode, iCtrlVarType_Temp)) &
          UnitarySystem(UnitarySysNum)%SystemCoolControlNodeNum = CoolingCoilOutletNode

        UnitarySystem(UnitarySysNum)%CoolCoilInletNodeNum  = CoolingCoilInletNode
        UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum = CoolingCoilOutletNode
        UnitarySystem(UnitarySysNum)%CoolingCoilName       = CoolingCoilName

        END IF

        IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .AND. &
            UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHPSimple) THEN
          UnitarySystem(UnitarySysNum)%WaterCyclingMode = WaterCycling
          CALL SetSimpleWSHPData(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrorsFound, &
                                 UnitarySystem(UnitarySysNum)%WaterCyclingMode, &
                                 CompanionHeatingCoilNum=UnitarySystem(UnitarySysNum)%HeatingCoilIndex)
        END IF

        IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPVSEquationFit .AND. &
            UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHPVSEquationFit) THEN
          CALL SetVarSpeedCoilData(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,ErrorsFound, &
                                CompanionHeatingCoilNum=UnitarySystem(UnitarySysNum)%HeatingCoilIndex)
        END IF

        ! Add cooling coil to component sets array
        IF(UnitarySystem(UnitarySysNum)%CoolCoilExists) THEN
          IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num .NE. CoilDX_MultiSpeedCooling) THEN
            CALL SetUpCompSets(CurrentModuleObject, Alphas(iNameAlphaNum), &
                               Alphas(iCoolingCoilTypeAlphaNum), Alphas(iCoolingCoilNameAlphaNum), &
                               NodeID(CoolingCoilInletNode), NodeID(CoolingCoilOutletNode))
          ELSE
            CALL SetUpCompSets(CurrentModuleObject, Alphas(iNameAlphaNum), &
                               Alphas(iCoolingCoilTypeAlphaNum), Alphas(iCoolingCoilNameAlphaNum), &
                               'UNDEFINED', 'UNDEFINED')
          END IF
        END IF
        ! Run as 100% DOAS DX coil
        IF (lAlphaBlanks(iDOASDXCoilAlphaNum) .AND. NumAlphas < iDOASDXCoilAlphaNum)THEN
            UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil= .FALSE.
        ELSE
            IF (SameString(Alphas(iDOASDXCoilAlphaNum),'Yes')) THEN
              UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil= .TRUE.
            ELSEIF (SameString(Alphas(iDOASDXCoilAlphaNum),' ')) THEN
              UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil= .FALSE.
            ELSEIF (SameString(Alphas(iDOASDXCoilAlphaNum),'No')) THEN
              UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil= .FALSE.
            ELSE
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Invalid entry for '//TRIM(cAlphaFields(iDOASDXCoilAlphaNum))//' :'// &
                                     TRIM(Alphas(iDOASDXCoilAlphaNum)))
              CALL ShowContinueError('Must be Yes or No.')
            END IF
        END IF

        ! considered as as 100% DOAS DX cooling coil
        IF (UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil) THEN
           ! set the system DX Coil application type to the child DX coil
           CALL SetDXCoilTypeData(UnitarySystem(UnitarySysNum)%CoolingCoilName)
        END IF
        ! DOAS DX Cooling Coil Leaving Minimum Air Temperature
        IF (NumNumbers > 0)THEN
          IF (.NOT. lNumericBlanks(iDOASDXMinTempNumericNum))THEN
             UnitarySystem(UnitarySysNum)%DOASDXCoolingCoilMinTout = Numbers(iDOASDXMinTempNumericNum)
          END IF
        END IF

        !Get Latent Load Control flag
        IF(.NOT. lAlphaBlanks(iRunOnLatentLoadAlphaNum))THEN
          IF(SameString(Alphas(iRunOnLatentLoadAlphaNum),'SensibleOnlyLoadControl')) THEN
            UnitarySystem(UnitarySysNum)%RunOnSensibleLoad = .TRUE.
            UnitarySystem(UnitarySysNum)%RunOnLatentLoad = .FALSE.
          ELSE IF(SameString(Alphas(iRunOnLatentLoadAlphaNum),'LatentOnlyLoadControl'))THEN
            UnitarySystem(UnitarySysNum)%RunOnSensibleLoad = .FALSE.
            UnitarySystem(UnitarySysNum)%RunOnLatentLoad = .TRUE.
          ELSE IF(SameString(Alphas(iRunOnLatentLoadAlphaNum),'LatentOrSensibleLoadControl'))THEN
            UnitarySystem(UnitarySysNum)%RunOnSensibleLoad = .TRUE.
            UnitarySystem(UnitarySysNum)%RunOnLatentLoad = .TRUE.
          ELSE IF(SameString(Alphas(iRunOnLatentLoadAlphaNum),'LatentWithSensibleLoadControl'))THEN
            UnitarySystem(UnitarySysNum)%RunOnSensibleLoad = .TRUE.
            UnitarySystem(UnitarySysNum)%RunOnLatentLoad = .TRUE.
            UnitarySystem(UnitarySysNum)%RunOnLatentOnlyWithSensible = .TRUE.
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Invalid entry for '//TRIM(cAlphaFields(iRunOnLatentLoadAlphaNum))//' :'// &
                                   TRIM(Alphas(iRunOnLatentLoadAlphaNum)))
            CALL ShowContinueError('Must be SensibleOnlyLoadControl, LatentOnlyLoadControl,'// &
                                   ' LatentOrSensibleLoadControl, or LatentWithSensibleLoadControl.')
          END IF
        END IF

        !Get reheat coil data if humidistat is used
        SuppHeatCoilType = Alphas(iSuppHeatCoilTypeAlphaNum)
        SuppHeatCoilName = Alphas(iSuppHeatCoilNameAlphaNum)
        UnitarySystem(UnitarySysNum)%SuppHeatCoilName = SuppHeatCoilName
        ErrFlag = .FALSE.

        IF (SameString(SuppHeatCoilType,'Coil:Heating:Water')) THEN
          UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num = Coil_HeatingWater
        ELSEIF (SameString(SuppHeatCoilType,'Coil:Heating:Steam')) THEN
          UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num = Coil_HeatingSteam
        ELSEIF (SameString(SuppHeatCoilType,'Coil:Heating:Gas')          .OR. &
                SameString(SuppHeatCoilType,'Coil:Heating:Electric')     .OR. &
                SameString(SuppHeatCoilType,'Coil:Heating:DesuperHeater')) THEN
            UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num = GetHeatingCoilTypeNum(SuppHeatCoilType,SuppHeatCoilName,ErrFlag)
        END IF

        IF(.NOT. lAlphaBlanks(iSuppHeatCoilTypeAlphaNum))THEN
          UnitarySystem(UnitarySysNum)%SuppCoilExists = .TRUE.

          IF (UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingGas          .OR. &
              UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingElectric     .OR. &
              UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingDesuperheater) THEN

            UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num = GetHeatingCoilTypeNum(SuppHeatCoilType,SuppHeatCoilName,ErrFlag)
            IF (ErrFlag) THEN
               CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
               ErrorsFound=.TRUE.
            ELSE

              CALL ValidateComponent(SuppHeatCoilType,SuppHeatCoilName,IsNotOK,  &
                                   TRIM(CurrentModuleObject))
              IF (IsNotOK) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                ErrorsFound=.TRUE.

              ELSE ! mine data from reheat coil

                ! Get the heating coil index
                CALL GetHeatingCoilIndex(SuppHeatCoilName,UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,IsNotOK)
                IF (IsNotOK) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound=.TRUE.
                END IF

                ! Get the design supplemental heating capacity
                ErrFlag=.FALSE.
                UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity =   &
                    GetHeatingCoilCapacity(SuppHeatCoilType,SuppHeatCoilName,ErrFlag)
                IF(UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity == Autosize) &
                     UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

                IF (ErrFlag) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound=.TRUE.
                END IF

                ! Get the Reheat Coil Inlet Node
                ErrFlag=.FALSE.
                SupHeatCoilInletNode = GetHeatingCoilInletNode(SuppHeatCoilType,SuppHeatCoilName,ErrFlag)
                IF (ErrFlag) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound=.TRUE.
                END IF

                ! Get the Reheat Coil Outlet Node
                ErrFlag=.FALSE.
                SupHeatCoilOutletNode = GetHeatingCoilOutletNode(SuppHeatCoilType,SuppHeatCoilName,ErrFlag)
                IF (ErrFlag) THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound=.TRUE.
                END IF

              END IF  ! IF (IsNotOK) THEN
            END IF

            UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode = SupHeatCoilInletNode
            UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode = SupHeatCoilOutletNode

          ELSEIF (UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingWater) THEN

            CALL ValidateComponent(SuppHeatCoilType,SuppHeatCoilName,IsNotOK,TRIM(CurrentModuleObject))
            IF (IsNotOK) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            ELSE ! mine data from heating coil object

                ! Get the Heating Coil water Inlet or control Node number
                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode = &
                      GetCoilWaterInletNode('Coil:Heating:Water',SuppHeatCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                END IF

                ! Get the ReHeat Coil hot water max volume flow rate
                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow = GetCoilMaxWaterFlowRate('Coil:Heating:Water',  &
                                                           SuppHeatCoilName,ErrFlag)
                IF(UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow == Autosize) &
                     UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                END IF

                ! Get the ReHeat Coil Inlet Node
                ErrFlag = .FALSE.
                SupHeatCoilInletNode =  GetWaterCoilInletNode('Coil:Heating:Water',SuppHeatCoilName,ErrFlag)
                UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode = SupHeatCoilInletNode
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                END IF

                ! Get the ReHeat Coil Outlet Node
                ErrFlag = .FALSE.
                SupHeatCoilOutletNode = GetWaterCoilOutletNode('Coil:Heating:Water',SuppHeatCoilName,ErrFlag)
                UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode = SupHeatCoilOutletNode
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                END IF

!                IF(UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow == Autosize) &
!                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
!                IF(UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity == Autosize) &
!                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            END IF

          ELSEIF (UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingSteam) THEN

            CALL ValidateComponent(SuppHeatCoilType,SuppHeatCoilName,IsNotOK,TRIM(CurrentModuleObject))
            IF (IsNotOK) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            ELSE ! mine data from heating coil object

                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex = GetSTeamCoilIndex('COIL:HEATING:STEAM',SuppHeatCoilName,ErrFlag)
                IF (UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex .EQ. 0) THEN
                    CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                    CALL ShowSevereError('Illegal '//TRIM(cAlphaFields(iSuppHeatCoilNameAlphaNum))//' = ' &
                                  //TRIM(SuppHeatCoilName))
                    ErrorsFound = .TRUE.
                END IF

                ! Get the Heating Coil steam inlet node number
                ErrFlag = .FALSE.
                UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode = &
                    GetSteamCoilSteamInletNode('Coil:Heating:Steam',SuppHeatCoilName,ErrFlag)
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                END IF

                ! Get the Heating Coil steam max volume flow rate
                UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow = &
                    GetCoilMaxSteamFlowRate(UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,ErrFlag)
                IF(UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow == Autosize) &
                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

                IF (UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow .GT. 0.0d0)THEN
                   SteamIndex = 0      ! Function GetSatDensityRefrig will look up steam index if 0 is passed
                   SteamDensity=GetSatDensityRefrig("STEAM",TempSteamIn,1.0d0,SteamIndex,'GetAirLoopHVACHeatCoolInput')
                   UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow = &
                                GetCoilMaxSteamFlowRate(UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,ErrFlag) * SteamDensity
                END IF

                ! Get the Heating Coil Inlet Node
                ErrFlag = .FALSE.
                SupHeatCoilInletNode = &
                         GetSteamCoilAirInletNode(UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,SuppHeatCoilName,ErrFlag)
                UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode = SupHeatCoilInletNode
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                END IF

                ! Get the Heating Coil Outlet Node
                ErrFlag = .FALSE.
                SupHeatCoilOutletNode = &
                         GetSteamCoilAirOutletNode(UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,SuppHeatCoilName,ErrFlag)
                UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode = SupHeatCoilOutletNode
                IF(ErrFlag)THEN
                  CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  ErrorsFound = .TRUE.
                END IF

!                IF(UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity == Autosize) &
!                   UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            END IF

          ELSE  ! Illegal reheating coil type
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iSuppHeatCoilTypeAlphaNum))//' = '// &
                                   TRIM(Alphas(iSuppHeatCoilTypeAlphaNum)))
            ErrorsFound=.TRUE.
          END IF ! IF (UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num == Coil_HeatingGas .OR. &, etc.

        END IF ! IF(.NOT. lAlphaBlanks(iSuppHeatCoilTypeAlphaNum))THEN

        IF(NodeHasSPMCtrlVarType(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum, iCtrlVarType_Temp)) &
            UnitarySystem(UnitarySysNum)%SuppHeatControlNodeNum = UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum
        IF(NodeHasSPMCtrlVarType(SupHeatCoilOutletNode, iCtrlVarType_Temp)) &
          UnitarySystem(UnitarySysNum)%SuppHeatControlNodeNum = SupHeatCoilOutletNode

        ! Add supplemental heating coil to component sets array
        IF(UnitarySystem(UnitarySysNum)%SuppCoilExists)CALL SetUpCompSets(CurrentModuleObject, Alphas(iNameAlphaNum), &
                             Alphas(iSuppHeatCoilTypeAlphaNum),Alphas(iSuppHeatCoilNameAlphaNum), &
                             NodeID(SupHeatCoilInletNode),NodeID(SupHeatCoilOutletNode))

        TotalZonesOnAirLoop = 0
        TotalFloorAreaOnAirLoop = 0.0d0
        AirLoopNumber = 0

 !***... only need to do this for load based control?
        ! Get the node number for the zone with the thermostat ! what if ControlZoneNum does = 0 if it's an OA sys?
        IF (UnitarySystem(UnitarySysNum)%ControlZoneNum >  0) THEN
          AirNodeFound=.FALSE.
          AirLoopFound=.FALSE.
          DO ControlledZoneNum = 1,NumOfZones
            IF (ZoneEquipConfig(ControlledZoneNum)%ActualZoneNum /= UnitarySystem(UnitarySysNum)%ControlZoneNum) CYCLE
!             Find the controlled zone number for the specified thermostat location
              UnitarySystem(UnitarySysNum)%NodeNumofControlledZone=ZoneEquipConfig(ControlledZoneNum)%ZoneNode
!             Determine if system is on air loop served by the thermostat location specified
              AirLoopNumber = ZoneEquipConfig(ControlledZoneNum)%AirLoopNum
              IF(AirLoopNumber .GT. 0)THEN
                DO BranchNum = 1, PrimaryAirSystem(AirLoopNumber)%NumBranches
                  DO CompNum = 1, PrimaryAirSystem(AirLoopNumber)%Branch(BranchNum)%TotalComponents
                    IF(.NOT. SameString(PrimaryAirSystem(AirLoopNumber)%Branch(BranchNum)%Comp(CompNum)%Name, &
                             Alphas(iNameAlphaNum)) .OR. &
                       .NOT. SameString(PrimaryAirSystem(AirLoopNumber)%Branch(BranchNum)%Comp(CompNum)%TypeOf, &
                             CurrentModuleObject))CYCLE
                    AirLoopFound=.TRUE.
                    EXIT
                  END DO
                  IF(AirLoopFound)EXIT
                END DO
                DO TstatZoneNum = 1, NumTempControlledZones
                  IF(TempControlledZone(TstatZoneNum)%ActualZoneNum .NE. UnitarySystem(UnitarySysNum)%ControlZoneNum)CYCLE
                  AirNodeFound=.TRUE.
                END DO
                DO TstatZoneNum = 1, NumComfortControlledZones
                  IF(ComfortControlledZone(TstatZoneNum)%ActualZoneNum .NE. UnitarySystem(UnitarySysNum)%ControlZoneNum)CYCLE
                  AirNodeFound=.TRUE.
                END DO
              END IF
            EXIT
          END DO
          IF(AirLoopNumber .GT. 0)THEN
            DO ControlledZoneNum = 1,NumOfZones
              IF (ZoneEquipConfig(ControlledZoneNum)%AirLoopNum == AirLoopNumber) THEN
                TotalZonesOnAirLoop = TotalZonesOnAirLoop + 1
                TotalFloorAreaOnAirLoop = TotalFloorAreaOnAirLoop+Zone(ZoneEquipConfig(ControlledZoneNum)%ActualZoneNum)%FloorArea
              END IF
            END DO
          ELSE
            IF (CurOASysNum > 0) THEN
!            IF(ALLOCATED(OutsideAirSys))THEN
              DO OASysNum = 1, NumOASystems
                DO OACompNum = 1, OutsideAirSys(OASysNum)%NumComponents
                  IF(.NOT. SameString(OutsideAirSys(OASysNum)%ComponentName(OACompNum), &
                           Alphas(iNameAlphaNum)) .OR. &
                     .NOT. SameString(OutsideAirSys(OASysNum)%ComponentType(OACompNum), &
                           CurrentModuleObject))CYCLE
                  AirLoopFound=.TRUE.
                  AirLoopNumber = OASysNum
                  UnitarySystem(UnitarySysNum)%AirLoopEquipment = .FALSE.
                  EXIT
                END DO
                IF(AirLoopFound)EXIT
              END DO
            END IF
          END IF
        ELSE ! this works IF it's zone equipment, but what IF it's air loop equipment?
          AirLoopScan: DO AirLoopNum = 1, NumPrimaryAirSys
            BranchScan: DO BranchNum = 1, PrimaryAirSystem(AirLoopNum)%NumBranches
              CompScan: DO CompNum = 1, PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%TotalComponents
                IF(SameString(PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%Name, Alphas(iNameAlphaNum)) .OR. &
                   SameString(PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%TypeOf, CurrentModuleObject))THEN
                  AirLoopNumber = AirLoopNum
                  AirLoopFound=.TRUE.
                ELSE IF(PrimaryAirSystem(AirLoopNum)%OASysExists)THEN
                  IF(ALLOCATED(OutsideAirSys))THEN
                    OASysScan: DO OASysNum = 1, NumOASystems
                      IF(.NOT. SameString(OutsideAirSys(OASysNum)%Name, &
                               PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%Name) .OR. &
                         .NOT. SameString('AirloopHVAC:OutdoorAirSystem', &
                               PrimaryAirSystem(AirLoopNum)%Branch(BranchNum)%Comp(CompNum)%TypeOf))CYCLE
                      DO OACompNum = 1, OutsideAirSys(OASysNum)%NumComponents
                        IF(.NOT. SameString(OutsideAirSys(OASysNum)%ComponentName(OACompNum), &
                                 Alphas(iNameAlphaNum)) .OR. &
                           .NOT. SameString(OutsideAirSys(OASysNum)%ComponentType(OACompNum), &
                                 CurrentModuleObject))CYCLE
                        AirLoopFound=.TRUE.
                        AirLoopNumber = AirLoopNum
                        UnitarySystem(UnitarySysNum)%AirLoopEquipment = .FALSE.
                        EXIT
                      END DO
!                      IF(AirLoopFound)EXIT OASysScan  WHY aren't these working? I get a break here in the debugger
                    END DO OASysScan
                  END IF
                END IF
!                IF(AirLoopFound)EXIT CompScan
              END DO CompScan
!              IF(AirLoopFound)EXIT BranchScan
            END DO BranchScan
!            IF(AirLoopFound)EXIT AirLoopScan
          END DO AirLoopScan
          IF(.NOT. AirLoopFound)THEN
            DO ControlledZoneNum = 1,NumOfZones
              DO ZoneExhNum = 1, ZoneEquipConfig(ControlledZoneNum)%NumExhaustNodes
                IF (ZoneEquipConfig(ControlledZoneNum)%ExhaustNode(ZoneExhNum) /= &
                    UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum) CYCLE
!               Find the controlled zone number for the specified thermostat location
                UnitarySystem(UnitarySysNum)%NodeNumofControlledZone=ZoneEquipConfig(ControlledZoneNum)%ZoneNode
                UnitarySystem(UnitarySysNum)%ControlZoneNum = ControlledZoneNum
                TotalFloorAreaOnAirLoop = Zone(ZoneEquipConfig(ControlledZoneNum)%ActualZoneNum)%FloorArea
                UnitarySystem(UnitarySysNum)%AirLoopEquipment = .FALSE.
                UnitarySystem(UnitarySysNum)%ZoneInletNode = ZoneEquipConfig(ControlledZoneNum)%ExhaustNode(ZoneExhNum)
                IF (ZoneEquipConfig(ControlledZoneNum)%EquipListIndex > 0) THEN
                  DO EquipNum = 1, ZoneEquipList(ZoneEquipConfig(ControlledZoneNum)%EquipListIndex)%NumOfEquipTypes
                    IF ((ZoneEquipList(ZoneEquipConfig(ControlledZoneNum)%EquipListIndex)%EquipType_Num(EquipNum) /= &
                         ZoneUnitarySystem_Num).OR. &
                       ZoneEquipList(ZoneEquipConfig(ControlledZoneNum)%EquipListIndex)%EquipName(EquipNum) /= &
                         UnitarySystem(UnitarySysNum)%Name)CYCLE
                      UnitarySystem(UnitarySysNum)%ZoneSequenceCoolingNum = &
                            ZoneEquipList(ZoneEquipConfig(ControlledZoneNum)%EquipListIndex)%CoolingPriority(EquipNum)
                      UnitarySystem(UnitarySysNum)%ZoneSequenceHeatingNum = &
                            ZoneEquipList(ZoneEquipConfig(ControlledZoneNum)%EquipListIndex)%HeatingPriority(EquipNum)
                  END DO
                END IF
                EXIT
              END DO
              DO ZoneInletNum = 1, ZoneEquipConfig(ControlledZoneNum)%NumInletNodes
                IF (ZoneEquipConfig(ControlledZoneNum)%InletNode(ZoneInletNum) /= &
                      UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum) CYCLE
                UnitarySystem(UnitarySysNum)%AirLoopEquipment = .FALSE.
                EXIT
              END DO
            END DO
          ELSE
            DO ControlledZoneNum = 1,NumOfZones
              IF (ZoneEquipConfig(ControlledZoneNum)%AirLoopNum == AirLoopNumber) THEN
                TotalZonesOnAirLoop = TotalZonesOnAirLoop + 1
                TotalFloorAreaOnAirLoop = TotalFloorAreaOnAirLoop+Zone(ZoneEquipConfig(ControlledZoneNum)%ActualZoneNum)%FloorArea
              END IF
            END DO
          END IF
        END IF

        IF (UnitarySystem(UnitarySysNum)%ControlZoneNum == 0 .AND. &
            UnitarySystem(UnitarySysNum)%ControlType == LoadBased) THEN
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iControlZoneAlphaNum))//' = '//TRIM(Alphas(iControlZoneAlphaNum)))
          ErrorsFound=.TRUE.
        END IF

        ! if a user connects the Unitary System as zone equipment, try to find the connection
        ZoneEquipmentFound=.FALSE.
        IF(UnitarySystem(UnitarySysNum)%AirLoopEquipment .AND. .NOT. AirLoopFound)THEN
          IF(UnitarySystem(UnitarySysNum)%ControlZoneNum > 0)THEN
            DO ControlledZoneNum = 1,NumOfZones
              DO ZoneExhNum = 1, ZoneEquipConfig(ControlledZoneNum)%NumExhaustNodes
                IF (ZoneEquipConfig(ControlledZoneNum)%ExhaustNode(ZoneExhNum) /= &
                    UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum) CYCLE
                IF(UnitarySystem(UnitarySysNum)%ControlZoneNum /= ControlledZoneNum)THEN
                  CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                  CALL ShowContinueError('Did not find Air Node (Zone with Thermostat).')
                  CALL ShowContinueError('specified '//TRIM(cAlphaFields(iControlZoneAlphaNum))//' = '// &
                                       TRIM(Alphas(iControlZoneAlphaNum)))
                  ErrorsFound=.TRUE.
                END IF
                IF(UnitarySystem(UnitarySysNum)%ControlZoneNum == ControlledZoneNum)THEN
                  ZoneEquipmentFound = .TRUE.
                  UnitarySystem(UnitarySysNum)%AirLoopEquipment = .FALSE.
                  UnitarySystem(UnitarySysNum)%ZoneInletNode = ZoneEquipConfig(ControlledZoneNum)%ExhaustNode(ZoneExhNum)
                END IF
              END DO
            END DO
          END IF
          IF(AirLoopNumber == 0 .AND. .NOT. ZoneEquipmentFound .AND. UnitarySystem(UnitarySysNum)%ControlType == LoadBased)THEN
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(Alphas(1)))
            CALL ShowContinueError('Did not find an AirLoopHVAC.')
            CALL ShowContinueError('specified '//TRIM(cAlphaFields(iControlZoneAlphaNum))//' = '// &
                                   TRIM(Alphas(iControlZoneAlphaNum)))
            IF (.not. AirNodeFound .AND. .NOT. ZoneEquipmentFound .AND. UnitarySystem(UnitarySysNum)%ControlType == LoadBased)THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(Alphas(1)))
              CALL ShowContinueError('Did not find air node (zone with thermostat).')
              CALL ShowContinueError('specified '//TRIM(cAlphaFields(iControlZoneAlphaNum))//' = '// &
                                   TRIM(Alphas(iControlZoneAlphaNum)))
              CALL ShowContinueError('Both a ZoneHVAC:EquipmentConnections object and a ZoneControl:Thermostat object' &
                                //' must be specified for this zone.')
            END IF
            IF (.not. AirLoopFound .AND. .NOT. ZoneEquipmentFound .AND. UnitarySystem(UnitarySysNum)%ControlType == LoadBased)THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(Alphas(1)))
              CALL ShowSevereError('Did not find correct AirLoopHVAC.')
              CALL ShowContinueError('specified '//TRIM(cAlphaFields(iControlZoneAlphaNum))//' = '// &
                                   TRIM(Alphas(iControlZoneAlphaNum)))
            END IF
            IF(UnitarySystem(UnitarySysNum)%ControlType == LoadBased)ErrorsFound=.TRUE.
          END IF
        END IF

        IF(.NOT. ZoneEquipmentFound)CALL TestCompSet(CurrentModuleObject,Alphas(iNameAlphaNum), &
              Alphas(iAirInletNodeNameAlphaNum),Alphas(iAirOutletNodeNameAlphaNum),'Air Nodes')

        ! Determine supply air flow rate sizing method for cooling mode
        IF(SameString(Alphas(iCoolSAFMAlphaNum),'SupplyAirFlowRate'))THEN
          UnitarySystem(UnitarySysNum)%CoolingSAFMethod    = SupplyAirFlowRate

          IF (.NOT. lNumericBlanks(iMaxCoolAirVolFlowNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow   = Numbers(iMaxCoolAirVolFlowNumericNum)
            IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            IF (UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .LE. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iMaxCoolAirVolFlowNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iMaxCoolAirVolFlowNumericNum),7)))
              ErrorsFound = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iMaxCoolAirVolFlowNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iCoolSAFMAlphaNum),'FlowPerFloorArea'))THEN

          UnitarySystem(UnitarySysNum)%CoolingSAFMethod    = FlowPerFloorArea
          IF (.NOT. lNumericBlanks(iCoolFlowPerFloorAreaNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow   = Numbers(iCoolFlowPerFloorAreaNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .LE. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iCoolFlowPerFloorAreaNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iCoolFlowPerFloorAreaNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iCoolFlowPerFloorAreaNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = &
                UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow * TotalFloorAreaOnAirLoop
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iCoolFlowPerFloorAreaNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iCoolSAFMAlphaNum),'FractionOfAutosizedCoolingValue'))THEN

          UnitarySystem(UnitarySysNum)%CoolingSAFMethod  = FractionOfAutosizedCoolingValue
          IF (.NOT. lNumericBlanks(iCoolFlowPerFracCoolNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Numbers(iCoolFlowPerFracCoolNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .LE. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iCoolFlowPerFracCoolNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iCoolFlowPerFracCoolNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iCoolFlowPerFracCoolNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iCoolFlowPerFracCoolNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iCoolSAFMAlphaNum),'FlowPerCoolingCapacity'))THEN

          UnitarySystem(UnitarySysNum)%CoolingSAFMethod  = FlowPerCoolingCapacity
          IF (.NOT. lNumericBlanks(iCoolFlowPerCoolCapNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = Numbers(iCoolFlowPerCoolCapNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .LE. 0.d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iCoolFlowPerCoolCapNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iCoolFlowPerCoolCapNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iCoolFlowPerCoolCapNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iCoolFlowPerCoolCapNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iCoolSAFMAlphaNum),'None') .OR. lAlphaBlanks(iCoolSAFMAlphaNum))THEN
          UnitarySystem(UnitarySysNum)%CoolingSAFMethod  = None
!          UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE. ! ??
        ELSE
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
          ErrorsFound=.TRUE.
        END IF

        ! Determine supply air flow rate sizing method for heating mode
        IF(SameString(Alphas(iHeatSAFMAlphaNum),'SupplyAirFlowRate'))THEN
          UnitarySystem(UnitarySysNum)%HeatingSAFMethod    = SupplyAirFlowRate
          IF (.NOT. lNumericBlanks(iMaxHeatAirVolFlowNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow   = Numbers(iMaxHeatAirVolFlowNumericNum)
            IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            IF (UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .LE. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iMaxHeatAirVolFlowNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iMaxHeatAirVolFlowNumericNum),7)))
              ErrorsFound = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iMaxHeatAirVolFlowNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iHeatSAFMAlphaNum),'FlowPerFloorArea'))THEN
          UnitarySystem(UnitarySysNum)%HeatingSAFMethod    = FlowPerFloorArea
          IF (.NOT. lNumericBlanks(iHeatFlowPerFloorAreaNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow   = Numbers(iHeatFlowPerFloorAreaNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .LE. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iHeatFlowPerFloorAreaNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iHeatFlowPerFloorAreaNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iHeatFlowPerFloorAreaNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = &
                UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow * TotalFloorAreaOnAirLoop
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iHeatFlowPerFloorAreaNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iHeatSAFMAlphaNum),'FractionOfAutosizedHeatingValue'))THEN
          UnitarySystem(UnitarySysNum)%HeatingSAFMethod  = FractionOfAutosizedHeatingValue
          IF (.NOT. lNumericBlanks(iHeatFlowPerFracCoolNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Numbers(iHeatFlowPerFracCoolNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .LE. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iHeatFlowPerFracCoolNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iHeatFlowPerFracCoolNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iHeatFlowPerFracCoolNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iHeatFlowPerFracCoolNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iHeatSAFMAlphaNum),'FlowPerHeatingCapacity'))THEN
          UnitarySystem(UnitarySysNum)%HeatingSAFMethod  = FlowPerHeatingCapacity
          IF (.NOT. lNumericBlanks(iHeatFlowPerHeatCapNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = Numbers(iHeatFlowPerHeatCapNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .LE. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iHeatFlowPerHeatCapNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iHeatFlowPerHeatCapNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iHeatFlowPerHeatCapNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iHeatFlowPerHeatCapNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iHeatSAFMAlphaNum),'None') .OR. lAlphaBlanks(iHeatSAFMAlphaNum))THEN
          UnitarySystem(UnitarySysNum)%HeatingSAFMethod  = None
!          UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE. ! ??
        ELSE
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
          ErrorsFound=.TRUE.
        END IF

        ! Determine supply air flow rate sizing method when cooling or heating is not needed
        IF(SameString(Alphas(iNoCoolHeatSAFMAlphaNum),'SupplyAirFlowRate'))THEN
          UnitarySystem(UnitarySysNum)%NoCoolHeatSAFMethod    = SupplyAirFlowRate
          IF (.NOT. lNumericBlanks(iMaxNoCoolHeatAirVolFlowNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = Numbers(iMaxNoCoolHeatAirVolFlowNumericNum)
            IF(UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow == Autosize) &
                 UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.

            IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .LT. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iMaxNoCoolHeatAirVolFlowNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iMaxNoCoolHeatAirVolFlowNumericNum),7)))
              ErrorsFound = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                   TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iMaxNoCoolHeatAirVolFlowNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iNoCoolHeatSAFMAlphaNum),'FlowPerFloorArea'))THEN
          UnitarySystem(UnitarySysNum)%NoCoolHeatSAFMethod    = FlowPerFloorArea
          IF (.NOT. lNumericBlanks(iNoCoolHeatFlowPerFloorAreaNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow   = Numbers(iNoCoolHeatFlowPerFloorAreaNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .LT. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                     TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iNoCoolHeatFlowPerFloorAreaNumericNum))//' = '// &
                                      TRIM(TrimSigDigits(Numbers(iNoCoolHeatFlowPerFloorAreaNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                     TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iNoCoolHeatFlowPerFloorAreaNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = &
                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow * TotalFloorAreaOnAirLoop
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                   TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iNoCoolHeatFlowPerFloorAreaNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iNoCoolHeatSAFMAlphaNum),'FractionOfAutosizedCoolingValue'))THEN
          UnitarySystem(UnitarySysNum)%NoCoolHeatSAFMethod  = FractionOfAutosizedCoolingValue
          IF (.NOT. lNumericBlanks(iNoCoolHeatFlowPerFracCoolNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = Numbers(iNoCoolHeatFlowPerFracCoolNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .LT. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                     TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iNoCoolHeatFlowPerFracCoolNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iNoCoolHeatFlowPerFracCoolNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                     TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iNoCoolHeatFlowPerFracCoolNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                   TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iNoCoolHeatFlowPerFracCoolNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iNoCoolHeatSAFMAlphaNum),'FractionOfAutosizedHeatingValue'))THEN
          UnitarySystem(UnitarySysNum)%NoCoolHeatSAFMethod  = FractionOfAutosizedHeatingValue
          IF (.NOT. lNumericBlanks(iNoCoolHeatFlowPerFracHeatNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = Numbers(iNoCoolHeatFlowPerFracHeatNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .LT. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                     TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iNoCoolHeatFlowPerFracHeatNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iNoCoolHeatFlowPerFracHeatNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                     TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iNoCoolHeatFlowPerFracHeatNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                   TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iNoCoolHeatFlowPerFracHeatNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iNoCoolHeatSAFMAlphaNum),'FlowPerCoolingCapacity'))THEN
          UnitarySystem(UnitarySysNum)%NoCoolHeatSAFMethod  = FlowPerCoolingCapacity
          IF (.NOT. lNumericBlanks(iNoCoolHeatFlowPerCoolCapNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = Numbers(iNoCoolHeatFlowPerCoolCapNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .LT. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                     TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iNoCoolHeatFlowPerCoolCapNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iNoCoolHeatFlowPerCoolCapNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                     TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iNoCoolHeatFlowPerCoolCapNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                   TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iNoCoolHeatFlowPerCoolCapNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iNoCoolHeatSAFMAlphaNum),'FlowPerHeatingCapacity'))THEN
          UnitarySystem(UnitarySysNum)%NoCoolHeatSAFMethod  = FlowPerHeatingCapacity
          IF (.NOT. lNumericBlanks(iNoCoolHeatFlowPerHeatCapNumericNum)) THEN
            UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow = Numbers(iNoCoolHeatFlowPerHeatCapNumericNum)
            IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .LT. 0.0d0 .AND. &
                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .NE. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                     TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iNoCoolHeatFlowPerHeatCapNumericNum))//' = '// &
                                     TRIM(TrimSigDigits(Numbers(iNoCoolHeatFlowPerHeatCapNumericNum),7)))
              ErrorsFound = .TRUE.
            ! Autosized input is not allowed
            ELSEIF(UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .EQ. AutoSize) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                     TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
              CALL ShowContinueError('Illegal '//TRIM(cNumericFields(iNoCoolHeatFlowPerHeatCapNumericNum))//' = Autosize')
              ErrorsFound = .TRUE.
            ELSE
              UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Input for '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                   TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
            CALL ShowContinueError('Blank field not allowed for '//TRIM(cNumericFields(iNoCoolHeatFlowPerHeatCapNumericNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(SameString(Alphas(iNoCoolHeatSAFMAlphaNum),'None') .OR. lAlphaBlanks(iNoCoolHeatSAFMAlphaNum))THEN
          UnitarySystem(UnitarySysNum)%NoCoolHeatSAFMethod  = None
!          UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE. ! ??
        ELSE
          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '// &
                                 TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
          ErrorsFound=.TRUE.
        END IF

!!       Check that the same air flow method is used if cooling and heating coil present
!        IF(UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
!          IF(UnitarySystem(UnitarySysNum)%CoolingSAFMethod /= UnitarySystem(UnitarySysNum)%HeatingSAFMethod .OR. &
!             UnitarySystem(UnitarySysNum)%CoolingSAFMethod /= UnitarySystem(UnitarySysNum)%NoCoolHeatSAFMethod)THEN
!          CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
!          CALL ShowContinueError('Illegal supply air flow method.')
!          CALL ShowContinueError(TRIM(cAlphaFields(iCoolSAFMAlphaNum))//' = '//TRIM(Alphas(iCoolSAFMAlphaNum)))
!          CALL ShowContinueError(TRIM(cAlphaFields(iHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iHeatSAFMAlphaNum)))
!          CALL ShowContinueError(TRIM(cAlphaFields(iNoCoolHeatSAFMAlphaNum))//' = '//TRIM(Alphas(iNoCoolHeatSAFMAlphaNum)))
!          CALL ShowContinueError('...Supply air flow methods must be the same when both a cooling and heating coil are present.')
!          ErrorsFound=.TRUE.
!          END IF
!        END IF

!       Fan operating mode (cycling or constant) schedule. IF constant fan, then set AirFlowControl
        IF(UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr .GT. 0)THEN
          IF (.NOT. CheckScheduleValueMinMax(UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr,'>=',0.0d0,'<=',0.0d0)) THEN
!           set fan operating mode to continuous so sizing can set VS coil data
            UnitarySystem(UnitarySysNum)%FanOpMode = ContFanCycCoil
!           set air flow control mode:
!             UseCompressorOnFlow = operate at last cooling or heating air flow requested when compressor is off
!             UseCompressorOffFlow = operate at value specified by user
!           AirFlowControl only valid if fan opmode = ContFanCycComp
            IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .EQ. 0.0d0) THEN
              UnitarySystem(UnitarySysNum)%AirFlowControl = UseCompressorOnFlow
            ELSE
              UnitarySystem(UnitarySysNum)%AirFlowControl = UseCompressorOffFlow
            END IF
          END IF
        END IF

       IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num /= CoilDX_CoolingHXAssisted .AND. &
          UnitarySystem(UnitarySysNum)%CoolingCoilType_Num /= CoilDX_CoolingTwoStageWHumControl .AND. &
          UnitarySystem(UnitarySysNum)%DehumidControlType_Num == DehumidControl_Multimode) THEN
         CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
         CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iDehumidControlAlphaNum))//' = '// &
                                TRIM(Alphas(iDehumidControlAlphaNum)))
         CALL ShowContinueError('Multimode control must be used with a Heat Exchanger Assisted or Multimode Cooling Coil.')
         IF(lAlphaBlanks(iSuppHeatCoilNameAlphaNum))THEN
         ELSE
           CALL ShowContinueError('Dehumidification control type is assumed to be CoolReheat'// &
                                  ' and the simulation continues.')
           UnitarySystem(UnitarySysNum)%DehumidControlType_Num = DehumidControl_CoolReheat
         END IF
       END IF

!       Check placement of cooling coil with respect to fan placement and dehumidification control type

       IF (UnitarySystem(UnitarySysNum)%FanExists) THEN
         IF(UnitarySystem(UnitarySysNum)%FanPlace == BlowThru)THEN
           IF(FanOutletNode == HeatingCoilInletNode .AND. &
              UnitarySystem(UnitarySysNum)%DehumidControlType_Num /= DehumidControl_CoolReheat)THEN
             UnitarySystem(UnitarySysNum)%CoolingCoilUpstream = .FALSE.
           END IF
         ELSEIF(UnitarySystem(UnitarySysNum)%FanPlace == DrawThru)THEN
           IF(HeatingCoilOutletNode == CoolingCoilInletNode .AND. &
              UnitarySystem(UnitarySysNum)%DehumidControlType_Num /= DehumidControl_CoolReheat)THEN
             UnitarySystem(UnitarySysNum)%CoolingCoilUpstream = .FALSE.
           END IF
         END IF
       ELSE
         IF(HeatingCoilOutletNode == CoolingCoilInletNode .AND. &
            UnitarySystem(UnitarySysNum)%DehumidControlType_Num /= DehumidControl_CoolReheat)THEN
           UnitarySystem(UnitarySysNum)%CoolingCoilUpstream = .FALSE.
         END IF
       END IF

       ! check node connections
       IF(UnitarySystem(UnitarySysNum)%FanPlace .EQ. BlowThru)THEN

          IF(FanInletNode /= UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum) THEN
             CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
             CALL ShowContinueError('When a blow through fan is specified, the fan inlet node name must be '// &
                                    'the same as the unitary system inlet node name.')
             CALL ShowContinueError('...Fan inlet node name           = '//TRIM(NodeID(FanInletNode)))
             CALL ShowContinueError('...UnitarySystem inlet node name = ' &
                                    //TRIM(NodeID(UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum)))
             ErrorsFound=.TRUE.
          END IF
          IF(UnitarySystem(UnitarySysNum)%CoolingCoilUpstream)THEN
            IF(FanOutletNode /= CoolingCoilInletNode .AND. &
               UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. UnitarySystem(UnitarySysNum)%FanExists) THEN
               CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
               CALL ShowContinueError('When a blow through fan is specified, the fan outlet node name must be '// &
                                      'the same as the cooling coil inlet node name.')
               CALL ShowContinueError('...Fan outlet node name         = '//TRIM(NodeID(FanOutletNode)))
               CALL ShowContinueError('...Cooling coil inlet node name = '//TRIM(NodeID(CoolingCoilInletNode)))
               ErrorsFound=.TRUE.
            END IF
            IF(CoolingCoilOutletNode /= HeatingCoilInletNode .AND. &
               UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. UnitarySystem(UnitarySysNum)%HeatCoilExists) THEN
               CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
               CALL ShowContinueError('The cooling coil outlet node name must be '// &
                                      'the same as the heating coil inlet node name.')
               CALL ShowContinueError('...Cooling coil outlet node name = '//TRIM(NodeID(CoolingCoilOutletNode)))
               CALL ShowContinueError('...Heating coil inlet node name  = '//TRIM(NodeID(HeatingCoilInletNode)))
               ErrorsFound=.TRUE.
            END IF
            IF(UnitarySystem(UnitarySysNum)%SuppCoilExists)THEN
              IF(SupHeatCoilOutletNode /= UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum) THEN
                CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                CALL ShowContinueError('The reheat coil outlet node name must be '// &
                                       'the same as the unitary system outlet node name.')
                CALL ShowContinueError('...Reheat coil outlet node name   = '//TRIM(NodeID(SupHeatCoilOutletNode)))
                CALL ShowContinueError('...UnitarySystem outlet node name = ' &
                                      //TRIM(NodeID(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)))
!                ErrorsFound=.TRUE.
              END IF
            ELSE ! IF((UnitarySystem(UnitarySysNum)%Humidistat ...
              ! Heating coil outlet node name must be the same as the Unitary system outlet node name
              IF (UnitarySystem(UnitarySysNum)%HeatCoilExists .AND. &
                  HeatingCoilOutletNode /= UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum) THEN
                CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                CALL ShowContinueError('When a blow through fan is specified, '//&
                               'the heating coil outlet node name must be the same as the unitary system outlet node name.')
                CALL ShowContinueError('...Heating coil outlet node name  = '//TRIM(NodeID(HeatingCoilOutletNode)))
                CALL ShowContinueError('...Unitary system outlet node name = ' &
                                         //TRIM(NodeID(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)))
                ErrorsFound=.TRUE.
              END IF
            END IF
          ELSE ! IF(UnitarySystem(UnitarySysNum)%CoolingCoilUpstream)THEN
            IF(FanOutletNode /= HeatingCoilInletNode .AND. UnitarySystem(UnitarySysNum)%FanExists .AND. &
               UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
               CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
               CALL ShowContinueError('When a blow through fan is specified, the fan outlet node name must be '// &
                                      'the same as the heating coil inlet node name.')
               CALL ShowContinueError('...Fan outlet node name         = '//TRIM(NodeID(FanOutletNode)))
               CALL ShowContinueError('...Heating coil inlet node name = '//TRIM(NodeID(HeatingCoilInletNode)))
               ErrorsFound=.TRUE.
            END IF
            IF(HeatingCoilOutletNode /= CoolingCoilInletNode .AND. UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. &
               UnitarySystem(UnitarySysNum)%HeatCoilExists) THEN
               CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
               CALL ShowContinueError('The heating coil outlet node name must be '// &
                                      'the same as the cooling coil inlet node name.')
               CALL ShowContinueError('...Heating coil outlet node name = '//TRIM(NodeID(HeatingCoilOutletNode)))
               CALL ShowContinueError('...Cooling coil inlet node name  = '//TRIM(NodeID(CoolingCoilInletNode)))
               ErrorsFound=.TRUE.
            END IF
            IF(CoolingCoilOutletNode /= UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum .AND. &
               UnitarySystem(UnitarySysNum)%CoolCoilExists) THEN
               CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
               CALL ShowContinueError('When a blow through fan is specified, the cooling coil outlet node name must be '// &
                                      'the same as the unitary system outlet node name.')
               CALL ShowContinueError('...Cooling coil outlet node name   = '//TRIM(NodeID(CoolingCoilOutletNode)))
               CALL ShowContinueError('...UnitarySystem outlet node name  = ' &
                                      //TRIM(NodeID(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)))
               ErrorsFound=.TRUE.
            END IF
          END IF

        ELSE ! ELSE from IF(UnitarySystem(UnitarySysNum)%FanPlace .EQ. BlowThru)THEN

          IF(UnitarySystem(UnitarySysNum)%CoolingCoilUpstream)THEN
            IF(CoolingCoilInletNode /= UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum .AND. &
               CoolingCoilInletNode /= 0 .AND. UnitarySystem(UnitarySysNum)%FanExists) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('When a draw through fan is specified, the cooling coil inlet node name must be '// &
                                     'the same as the unitary system inlet node name.')
              CALL ShowContinueError('...Cooling coil inlet node name  = '//TRIM(NodeID(CoolingCoilInletNode)))
              CALL ShowContinueError('...UnitarySystem inlet node name = ' &
                                     //TRIM(NodeID(UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum)))
                ErrorsFound=.TRUE.
            END IF
            IF(CoolingCoilOutletNode /= HeatingCoilInletNode .AND. &
               UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. UnitarySystem(UnitarySysNum)%HeatCoilExists) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('The cooling coil outlet node name must be '// &
                                     'the same as the heating coil inlet node name.')
              CALL ShowContinueError('...Cooling coil outlet node name = '//TRIM(NodeID(CoolingCoilOutletNode)))
              CALL ShowContinueError('...Heating coil inlet node name  = '//TRIM(NodeID(HeatingCoilInletNode)))
              ErrorsFound=.TRUE.
            END IF
            IF(HeatingCoilOutletNode /= FanInletNode .AND. &
               UnitarySystem(UnitarySysNum)%HeatCoilExists .AND. UnitarySystem(UnitarySysNum)%FanExists) THEN
              CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('When a draw through fan is specified, the heating coil outlet node name must be '// &
                                     'the same as the fan inlet node name.')
              CALL ShowContinueError('...Heating coil outlet node name = '//TRIM(NodeID(HeatingCoilOutletNode)))
              CALL ShowContinueError('...Fan inlet node name           = '//TRIM(NodeID(FanInletNode)))
              ErrorsFound=.TRUE.
            END IF
            IF(UnitarySystem(UnitarySysNum)%SuppCoilExists)THEN
              IF(FanOutletNode /= SupHeatCoilInletNode .AND. UnitarySystem(UnitarySysNum)%FanExists) THEN
                CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                CALL ShowContinueError('When a draw through fan is specified, the fan outlet node name must be '// &
                                       'the same as the reheat coil inlet node name.')
                CALL ShowContinueError('...Fan outlet node name        = '//TRIM(NodeID(FanOutletNode)))
                CALL ShowContinueError('...Reheat coil inlet node name = '//TRIM(NodeID(SupHeatCoilInletNode)))
!                ErrorsFound=.TRUE.
              END IF
              IF(SupHeatCoilOutletNode /= UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum) THEN
                CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                CALL ShowContinueError('The reheat coil outlet node name must be '// &
                                       'the same as the unitary system outlet node name.')
                CALL ShowContinueError('...Reheat coil outlet node name   = '//TRIM(NodeID(SupHeatCoilOutletNode)))
                CALL ShowContinueError('...UnitarySystem outlet node name = ' &
                                                  //TRIM(NodeID(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)))
              END IF
            ELSE
              IF(FanOutletNode /= UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum .AND. &
                 UnitarySystem(UnitarySysNum)%FanExists) THEN
                CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                CALL ShowContinueError('When a draw through fan is specified, the fan outlet node name must be '// &
                                       'the same as the unitary system outlet node name.')
                CALL ShowContinueError('...Fan outlet node name        = '//TRIM(NodeID(FanOutletNode)))
                CALL ShowContinueError('...Unitary system outlet node name = '// &
                                       TRIM(NodeID(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)))
                ErrorsFound=.TRUE.
              END IF
            END IF
          ELSE ! IF(UnitarySystem(UnitarySysNum)%CoolingCoilUpstream)THEN
            IF(HeatingCoilInletNode /= UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum .AND. &
               HeatingCoilInletNode /= 0 .AND. UnitarySystem(UnitarySysNum)%FanExists) THEN
               CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
               CALL ShowContinueError('When a draw through fan is specified, the heating coil inlet node name must be '// &
                                      'the same as the unitary system inlet node name.')
               CALL ShowContinueError('...Heating coil inlet node name  = '//TRIM(NodeID(HeatingCoilInletNode)))
               CALL ShowContinueError('...UnitarySystem inlet node name = ' &
                                      //TRIM(NodeID(UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum)))
               ErrorsFound=.TRUE.
            END IF
            IF(HeatingCoilOutletNode /= CoolingCoilInletNode .AND. &
               UnitarySystem(UnitarySysNum)%HeatCoilExists .AND. UnitarySystem(UnitarySysNum)%CoolCoilExists) THEN
               CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
               CALL ShowContinueError('The heating coil outlet node name must be '// &
                                      'the same as the cooling coil inlet node name.')
               CALL ShowContinueError('...Heating coil outlet node name = '//TRIM(NodeID(HeatingCoilOutletNode)))
               CALL ShowContinueError('...Cooling coil inlet node name  = '//TRIM(NodeID(CoolingCoilInletNode)))
               ErrorsFound=.TRUE.
            END IF
            IF(CoolingCoilOutletNode /= FanInletNode .AND. &
               UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. UnitarySystem(UnitarySysNum)%FanExists) THEN
               CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
               CALL ShowContinueError('When a draw through fan is specified, the cooling coil outlet node name must be '// &
                                      'the same as the fan inlet node name.')
               CALL ShowContinueError('...Cooling coil outlet node name = '//TRIM(NodeID(CoolingCoilOutletNode)))
               CALL ShowContinueError('...Fan inlet node name           = '//TRIM(NodeID(FanInletNode)))
               ErrorsFound=.TRUE.
            END IF
            IF(FanOutletNode /= UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum .AND. &
               UnitarySystem(UnitarySysNum)%FanExists) THEN
               CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
               CALL ShowContinueError('When a draw through fan is specified, the fan outlet node name must be '// &
                                      'the same as the unitary system outlet node name.')
               CALL ShowContinueError('...Fan outlet node name           = '//TRIM(NodeID(FanOutletNode)))
               CALL ShowContinueError('...UnitarySystem outlet node name = ' &
                                       //TRIM(NodeID(UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum)))
               ErrorsFound=.TRUE.
            END IF
          END IF
        END IF ! ELSE from IF(UnitarySystem(UnitarySysNum)%FanPlace .EQ. BlowThru)THEN

        !Set the unitary system supplemental heater max outlet temperature
        ! this field will be 0 if the input is not specified (included) in the input file
        ! someone may use a default other than what we intended, allow it to be used
        ! so if this field is blank, and the input field is included, read the default, otherwise use 80
        IF (.NOT. lNumericBlanks(iDesignMaxOutletTempNumericNum) .AND. NumNumbers .GT. (iDesignMaxOutletTempNumericNum-1)) THEN
          UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp = Numbers(iDesignMaxOutletTempNumericNum)
          IF(UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp == Autosize) &
               UnitarySystem(UnitarySysNum)%RequestAutosize = .TRUE.
        END IF

        !Set maximum Outdoor air temperature for supplemental heating coil operation
        ! this field will be 0 if the input is not specified (included) in the input file
        ! someone may use a default other than what we intended, allow it to be used
        ! so if this field is blank, and the input field is included, read the default, otherwise use 9999
        IF (.NOT. lNumericBlanks(iMaxOATSuppHeatNumericNum) .AND. NumNumbers .GT. (iMaxOATSuppHeatNumericNum-1)) THEN
          UnitarySystem(UnitarySysNum)%MaxOATSuppHeat = Numbers(iMaxOATSuppHeatNumericNum)
        ! Can't let MaxOATSuppHeat default to 21C if using cool reheat since it would shut off supp heater when dehumidifying
        ! this may also allow supplemental heater to operate when in heating mode when it should not
        ELSE IF(NumNumbers .LT. iMaxOATSuppHeatNumericNum .AND. &
                UnitarySystem(UnitarySysNum)%DehumidControlType_Num == DehumidControl_CoolReheat)THEN
          UnitarySystem(UnitarySysNum)%MaxOATSuppHeat = 999.0d0
        END IF

        IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .NE. Autosize .AND. &
           UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .NE. Autosize .AND. &
           UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .NE. Autosize .AND. &
           .NOT. UnitarySystem(UnitarySysNum)%RequestAutosize)THEN
!           (UnitarySystem(UnitarySysNum)%CoolingSAFMethod .LE. SupplyAirFlowRate .OR. &
!            UnitarySystem(UnitarySysNum)%HeatingSAFMethod .LE. SupplyAirFlowRate))THEN
          UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = MAX(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow, &
                                                                    UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow, &
                                                                    UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow)
        ELSE
          IF(UnitarySystem(UnitarySysNum)%FanExists)THEN
            UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = Autosize
          END IF
  ! need more of this type of warning when flow cannot be determined
          IF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .EQ. 0.0d0 .AND. &
             UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
             IF(UnitarySystem(UnitarySysNum)%FanExists)THEN
               IF(UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. &
                  UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow /= Autosize)THEN
                 IF(UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow == 0.0d0)THEN
                   UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate
                 END IF
               END IF
             ELSEIF(UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
               UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow
             ELSE
               IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num /= CoilDX_HeatingEmpirical .AND. &
                  UnitarySystem(UnitarySysNum)%HeatingCoilType_Num /= CoilDX_MultiSpeedHeating .AND. &
                  UnitarySystem(UnitarySysNum)%HeatingCoilType_Num /= Coil_HeatingAirToAirVariableSpeed)THEN
                 CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                 CALL ShowContinueError('When non-DX heating coils are specified, the heating air flow rate must be '// &
                                        'entered in '//TRIM(cAlphaFields(iHeatSAFMAlphaNum)))
                 ErrorsFound=.TRUE.
               END IF
             END IF
          ELSEIF(UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .EQ. 0.0d0 .AND. &
             .NOT. UnitarySystem(UnitarySysNum)%FanExists .AND. &
             .NOT. UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
                 CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                 CALL ShowContinueError('When non-DX heating coils are specified, the heating air flow rate must be '// &
                                        'entered in '//TRIM(cAlphaFields(iHeatSAFMAlphaNum)))
          END IF
        END IF

        IF(FanVolFlowRate .NE. AutoSize .AND. UnitarySystem(UnitarySysNum)%FanExists)THEN
          IF(FanVolFlowRate .LT. UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .AND. &
               UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow .NE. AutoSize .AND. &
               UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('... air flow rate = '//TRIM(TrimSigDigits(FanVolFlowRate,7))//' in fan object '// &
                 TRIM(FanName)//' is less than the maximum HVAC system air flow rate in cooling mode.')
            CALL ShowContinueError(' The '//TRIM(cNumericFields(iMaxCoolAirVolFlowNumericNum))//' is reset to the' &
                                 //' fan flow rate and the simulation continues.')
            UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlow = FanVolFlowRate
            UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = FanVolFlowRate
          END IF
          IF(FanVolFlowRate .LT. UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .AND. &
               UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow .NE. AutoSize .AND. &
               UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('... air flow rate = '//TRIM(TrimSigDigits(FanVolFlowRate,7))//' in fan object '// &
                 TRIM(FanName)//' is less than the maximum HVAC system air flow rate in heating mode.')
            CALL ShowContinueError(' The '//TRIM(cNumericFields(3))//' is reset to the' &
                                 //' fan flow rate and the simulation continues.')
            UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlow = FanVolFlowRate
            UnitarySystem(UnitarySysNum)%DesignFanVolFlowRate = FanVolFlowRate
          END IF
        END IF

        IF(UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr .GT. 0)THEN
          IF (.NOT. CheckScheduleValueMinMax(UnitarySystem(UnitarySysNum)%FanOpModeSchedPtr,'>=',0.0d0,'<=',0.0d0)) THEN
!           set air flow control mode:
!             UseCompressorOnFlow = operate at last cooling or heating air flow requested when compressor is off
!             UseCompressorOffFlow = operate at value specified by user
!           AirFlowControl only valid IF fan opmode = ContFanCycComp
            IF (UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlow .EQ. 0.0d0) THEN
              UnitarySystem(UnitarySysNum)%AirFlowControl = UseCompressorOnFlow
            ELSE
              UnitarySystem(UnitarySysNum)%AirFlowControl = UseCompressorOffFlow
            END IF
          END IF
        END IF

        !Set minimum OAT for heat pump compressor operation
        ! get from coil module
        ErrFlag=.FALSE.
        IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed) THEN
            UnitarySystem(UnitarySysNum)%MinOATCompressor = GetVSCoilMinOATCompressor(HeatingCoilName,ErrFlag)
        ELSEIF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical .OR. &
                UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating) THEN
            UnitarySystem(UnitarySysNum)%MinOATCompressor =    &
               GetMinOATDXCoilCompressor(HeatingCoilType,HeatingCoilName,ErrFlag)
!       ELSEIF  ***... make sure we catch all possbile coil types here ...***
        ELSE
            UnitarySystem(UnitarySysNum)%MinOATCompressor = -1000.0d0
        END IF
        IF (ErrFlag) THEN
          CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          ErrorsFound=.TRUE.
        END IF


!       Mine heatpump Outdoor condenser node from DX coil object
        ErrFlag=.FALSE.
        IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingSingleSpeed) THEN
          UnitarySystem(UnitarySysNum)%CondenserNodeNum = &
            GetDXCoilCondenserInletNode(CoolingCoilType,CoolingCoilName,ErrFlag)
        ELSEIF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingAirToAirVariableSpeed) THEN
          UnitarySystem(UnitarySysNum)%CondenserNodeNum = GetVSCoilCondenserInletNode(CoolingCoilName,ErrFlag)
        ELSEIF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingHXAssisted) THEN
          UnitarySystem(UnitarySysNum)%CondenserNodeNum = &
            GetDXCoilCondenserInletNode('Coil:Cooling:DX:SingleSpeed', &
            GetHXDXCoilName(CoolingCoilType,CoolingCoilName,ErrFlag), &
            ErrFlag)
        ELSE
          IF(.NOT. lAlphaBlanks(iCondenserNodeAlphaNum))THEN
            UnitarySystem(UnitarySysNum)%CondenserNodeNum = &
               GetOnlySingleNode(Alphas(iCondenserNodeAlphaNum),ErrFlag,CurrentModuleObject,Alphas(1), &
                            NodeType_Air,NodeConnectionType_Inlet,1,ObjectIsParent)
          ELSE
            ! do nothing?
          END IF
        END IF
        IF (ErrFlag) THEN
          CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
          ErrorsFound=.TRUE.
        END IF

        !Set the heatpump cycling rate
        UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour = Numbers(iMaxONOFFCycPerHourNumericNum)
        IF(NumNumbers .LT. iMaxONOFFCycPerHourNumericNum)THEN
          UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour = 2.5d0
        END IF

        !Set the heat pump time constant
        UnitarySystem(UnitarySysNum)%HPTimeConstant = Numbers(iHPTimeConstantNumericNum)
        IF(NumNumbers .LT. iHPTimeConstantNumericNum)THEN
          UnitarySystem(UnitarySysNum)%HPTimeConstant = 60.0d0
        END IF

        !Set the heat pump on-cycle power use fraction
        UnitarySystem(UnitarySysNum)%OnCyclePowerFraction = Numbers (iOnCyclePowerFracNumericNum)
        IF(NumNumbers .LT. iOnCyclePowerFracNumericNum)THEN
          UnitarySystem(UnitarySysNum)%OnCyclePowerFraction = 0.01d0
        END IF

        !Set the heat pump fan delay time
        UnitarySystem(UnitarySysNum)%FanDelayTime = Numbers(iFanDelayTimeNumericNum)
        IF(NumNumbers .LT. iFanDelayTimeNumericNum)THEN
          UnitarySystem(UnitarySysNum)%FanDelayTime = 60.0d0
        END IF

        UnitarySystem(UnitarySysNum)%AncillaryOnPower  = Numbers(iAncillaryOnPowerNumericNum)
        UnitarySystem(UnitarySysNum)%AncillaryOffPower = Numbers(iAncillaryOffPowerNumericNum)

        UnitarySystem(UnitarySysNum)%DesignHRWaterVolumeFlow = Numbers(iDesignHRWaterVolFlowNumericNum)
        UnitarySystem(UnitarySysNum)%MaxHROutletWaterTemp = Numbers(iMaxHROutletWaterTempNumericNum)

        IF(UnitarySystem(UnitarySysNum)%DesignHRWaterVolumeFlow .GT. 0.0d0)THEN
          UnitarySystem(UnitarySysNum)%HeatRecActive = .TRUE.
          ErrFlag=.FALSE.
          IF(.NOT. lAlphaBlanks(iHRWaterInletNodeAlphaNum) .AND. .NOT. lAlphaBlanks(iHRWaterOutletNodeAlphaNum))THEN
            UnitarySystem(UnitarySysNum)%HeatRecoveryInletNodeNum = &
              GetOnlySingleNode(Alphas(iHRWaterInletNodeAlphaNum),ErrFlag,'Unitary System Heat receovery',Alphas(iNameAlphaNum), &
                NodeType_Water,NodeConnectionType_Inlet,3,ObjectIsParent)
            UnitarySystem(UnitarySysNum)%HeatRecoveryOutletNodeNum = &
              GetOnlySingleNode(Alphas(iHRWaterOutletNodeAlphaNum),ErrFlag,'Unitary System Heat receovery',Alphas(iNameAlphaNum), &
                NodeType_Water,NodeConnectionType_Inlet,3,ObjectIsParent)

            CALL TestCompSet(CurrentModuleObject,Alphas(iNameAlphaNum),Alphas(iHRWaterInletNodeAlphaNum), &
                             Alphas(iHRWaterOutletNodeAlphaNum), 'Unitary System Heat receovery Nodes')

            IF (ErrFlag) THEN
              CALL ShowContinueError('Occurs in '//TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
              ErrorsFound=.TRUE.
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iHRWaterInletNodeAlphaNum))//' = '// &
                                   TRIM(Alphas(iHRWaterInletNodeAlphaNum)))
            CALL ShowContinueError('Illegal '//TRIM(cAlphaFields(iHRWaterOutletNodeAlphaNum))//' = '// &
                                   TRIM(Alphas(iHRWaterOutletNodeAlphaNum)))
            CALL ShowContinueError('... heat recovery nodes must be specified when ' &
                                   //TRIM(cNumericFields(iDesignHRWaterVolFlowNumericNum))//' is greater than 0.')
            CALL ShowContinueError('... '//TRIM(cNumericFields(iDesignHRWaterVolFlowNumericNum))//' = '// &
                                   TRIM(TrimSigDigits(UnitarySystem(UnitarySysNum)%DesignHRWaterVolumeFlow,7)))
            ErrorsFound=.TRUE.
          END IF
        END IF

        IF(.NOT. lAlphaBlanks(iDesignSpecMSHPTypeAlphaNum) .AND. .NOT. lAlphaBlanks(iDesignSpecMSHPNameAlphaNum))THEN
          UnitarySystem(UnitarySysNum)%DesignSpecMultispeedHPType = Alphas(iDesignSpecMSHPTypeAlphaNum)
          UnitarySystem(UnitarySysNum)%DesignSpecMultispeedHPName = Alphas(iDesignSpecMSHPNameAlphaNum)

          UnitarySystem(UnitarySysNum)%DesignSpecMSHPIndex = &
            FindItemInList(UnitarySystem(UnitarySysNum)%DesignSpecMultispeedHPName,DesignSpecMSHP%Name,NumDesignSpecMultiSpeedHP)
          DesignSpecNum = UnitarySystem(UnitarySysNum)%DesignSpecMSHPIndex

          IF(DesignSpecNum .GT. 0)THEN

            IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
                UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingElectric_MultiStage .OR. &
                UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingGas_MultiStage) THEN
              UnitarySystem(UnitarySysNum)%NumOfSpeedHeating = DesignSpecMSHP(DesignSpecNum)%NumOfSpeedHeating
              ALLOCATE(UnitarySystem(UnitarySysNum)%HeatMassFlowRate(DesignSpecMSHP(DesignSpecNum)%NumOfSpeedHeating))
              ALLOCATE(UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(DesignSpecMSHP(DesignSpecNum)%NumOfSpeedHeating))
              ALLOCATE(UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(DesignSpecMSHP(DesignSpecNum)%NumOfSpeedHeating))
              UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio = 1.0d0
            END IF

            IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling) THEN
              UnitarySystem(UnitarySysNum)%NumOfSpeedCooling = DesignSpecMSHP(DesignSpecNum)%NumOfSpeedCooling
              ALLOCATE(UnitarySystem(UnitarySysNum)%CoolMassFlowRate(DesignSpecMSHP(DesignSpecNum)%NumOfSpeedCooling))
              ALLOCATE(UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(DesignSpecMSHP(DesignSpecNum)%NumOfSpeedCooling))
              ALLOCATE(UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(DesignSpecMSHP(DesignSpecNum)%NumOfSpeedCooling))
              UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio = 1.0d0
            END IF
          ELSE
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('... one or both of the following inputs are invalid.')
            CALL ShowContinueError('Field '//TRIM(cAlphaFields(iDesignSpecMSHPTypeAlphaNum))//' = '// &
                                   TRIM(Alphas(iDesignSpecMSHPTypeAlphaNum)))
            CALL ShowContinueError('Field '//TRIM(cAlphaFields(iDesignSpecMSHPNameAlphaNum))//' = '// &
                                   TRIM(Alphas(iDesignSpecMSHPNameAlphaNum)))
            ErrorsFound = .TRUE.
          END IF
        ELSEIF(lAlphaBlanks(iDesignSpecMSHPTypeAlphaNum) .AND. .NOT. lAlphaBlanks(iDesignSpecMSHPNameAlphaNum) .OR. &
                .NOT. lAlphaBlanks(iDesignSpecMSHPTypeAlphaNum) .AND. lAlphaBlanks(iDesignSpecMSHPNameAlphaNum))THEN
            CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('... one or both of the following inputs are invalid.')
            CALL ShowContinueError('Field '//TRIM(cAlphaFields(iDesignSpecMSHPTypeAlphaNum))//' = '// &
                                   TRIM(Alphas(iDesignSpecMSHPTypeAlphaNum)))
            CALL ShowContinueError('Field '//TRIM(cAlphaFields(iDesignSpecMSHPNameAlphaNum))//' = '// &
                                   TRIM(Alphas(iDesignSpecMSHPNameAlphaNum)))
            ErrorsFound = .TRUE.
        ELSEIF(UnitarySystem(UnitarySysNum)%NumOfSpeedHeating .GT. 0)THEN
          NumOfSpeedHeating = UnitarySystem(UnitarySysNum)%NumOfSpeedHeating

          ALLOCATE(UnitarySystem(UnitarySysNum)%HeatMassFlowRate(NumOfSpeedHeating))
          ALLOCATE(UnitarySystem(UnitarySysNum)%HeatVolumeFlowRate(NumOfSpeedHeating))
          ALLOCATE(UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(NumOfSpeedHeating))
          UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio = 1.0d0

        ELSEIF(UnitarySystem(UnitarySysNum)%NumOfSpeedCooling .GT. 0)THEN
          NumOfSpeedCooling = UnitarySystem(UnitarySysNum)%NumOfSpeedCooling

          ALLOCATE(UnitarySystem(UnitarySysNum)%CoolMassFlowRate(NumOfSpeedCooling))
          ALLOCATE(UnitarySystem(UnitarySysNum)%CoolVolumeFlowRate(NumOfSpeedCooling))
          ALLOCATE(UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(NumOfSpeedCooling))
          UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio = 1.0d0

        END IF

        IF(UnitarySystem(UnitarySysNum)%MultiSpeedCoolingCoil) THEN

           Index = UnitarySystem(UnitarySysNum)%DesignSpecMSHPIndex
           IF(Index .GT. 0) &
             UnitarySystem(UnitarySysNum)%NumOfSpeedCooling = DesignSpecMSHP(Index)%NumOfSpeedCooling

           IF (UnitarySystem(UnitarySysNum)%NumOfSpeedCooling == 0) THEN
             CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
             CALL ShowContinueError('... Cooling coil object type requires valid number of speeds for cooling to be specified')
            ErrorsFound = .TRUE.
           END IF
        END IF
        IF(UnitarySystem(UnitarySysNum)%MultiSpeedHeatingCoil) THEN

           Index = UnitarySystem(UnitarySysNum)%DesignSpecMSHPIndex
           IF(Index .GT. 0) &
             UnitarySystem(UnitarySysNum)%NumOfSpeedHeating = DesignSpecMSHP(Index)%NumOfSpeedHeating

           IF (UnitarySystem(UnitarySysNum)%NumOfSpeedHeating == 0) THEN
             CALL ShowSevereError(TRIM(CurrentModuleObject)//' = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
             CALL ShowContinueError('... Heating coil object type requires valid number of speeds for heating to be specified')
            ErrorsFound = .TRUE.
           END IF
        END IF

        ! set global logicals that denote coil type
        IF (UnitarySystem(UnitarySysNum)%MultiSpeedHeatingCoil .OR. UnitarySystem(UnitarySysNum)%VarSpeedHeatingCoil) THEN
          MultiOrVarSpeedHeatCoil(UnitarySysNum) = .TRUE.
        END IF
        IF (UnitarySystem(UnitarySysNum)%MultiSpeedCoolingCoil .OR. UnitarySystem(UnitarySysNum)%VarSpeedCoolingCoil) THEN
          MultiOrVarSpeedCoolCoil(UnitarySysNum) = .TRUE.
        END IF

      END DO  !End of the Unitary System Loop

      IF (ErrorsFound) THEN
          CALL ShowFatalError(RoutineName//'Errors found in input.  Program terminates.')
      END IF

      ! Setup Report variables for the Unitary System that are not reported in the components themselves
      DO UnitarySysNum=1,NumUnitarySystem
        CALL SetupOutputVariable('Unitary System Part Load Ratio []',UnitarySystem(UnitarySysNum)%PartLoadFrac, &
                             'System','Average',UnitarySystem(UnitarySysNum)%Name)
        CALL SetupOutputVariable('Unitary System Total Cooling Rate [W]',UnitarySystem(UnitarySysNum)%TotCoolEnergyRate, &
                             'System','Average',UnitarySystem(UnitarySysNum)%Name)
        CALL SetupOutputVariable('Unitary System Sensible Cooling Rate [W]',UnitarySystem(UnitarySysNum)%SensCoolEnergyRate, &
                             'System','Average',UnitarySystem(UnitarySysNum)%Name)
        CALL SetupOutputVariable('Unitary System Latent Cooling Rate [W]',UnitarySystem(UnitarySysNum)%LatCoolEnergyRate, &
                             'System','Average',UnitarySystem(UnitarySysNum)%Name)
        CALL SetupOutputVariable('Unitary System Total Heating Rate [W]',UnitarySystem(UnitarySysNum)%TotHeatEnergyRate, &
                             'System','Average',UnitarySystem(UnitarySysNum)%Name)
        CALL SetupOutputVariable('Unitary System Sensible Heating Rate [W]',UnitarySystem(UnitarySysNum)%SensHeatEnergyRate, &
                             'System','Average',UnitarySystem(UnitarySysNum)%Name)
        CALL SetupOutputVariable('Unitary System Latent Heating Rate [W]',UnitarySystem(UnitarySysNum)%LatHeatEnergyRate, &
                             'System','Average',UnitarySystem(UnitarySysNum)%Name)
        CALL SetupOutputVariable('Unitary System Ancillary Electric Power [W]', &
                              UnitarySystem(UnitarySysNum)%TotalAuxElecPower, &
                             'System','Average',UnitarySystem(UnitarySysNum)%Name)

!        IF(UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_CoolReheat)THEN
          CALL SetupOutputVariable('Unitary System Dehumidification Induced Heating Demand Rate [W]', &
                                   UnitarySystem(UnitarySysNum)%DehumidInducedHeatingDemandRate, 'System','Average', &
                                   UnitarySystem(UnitarySysNum)%Name)
!        END IF

        IF(UnitarySystem(UnitarySysNum)%FanExists)THEN
          CALL SetupOutputVariable('Unitary System Fan Part Load Ratio []',UnitarySystem(UnitarySysNum)%FanPartLoadRatio, &
                             'System','Average',UnitarySystem(UnitarySysNum)%Name)
        END IF

        CALL SetupOutputVariable('Unitary System Compressor Part Load Ratio []', &
                                 UnitarySystem(UnitarySysNum)%CompPartLoadRatio, &
                                 'System','Average',UnitarySystem(UnitarySysNum)%Name)

        CALL SetupOutputVariable('Unitary System Frost Control Status []',UnitarySystem(UnitarySysNum)%FrostControlStatus, &
                                 'System','Average',UnitarySystem(UnitarySysNum)%Name)

        IF(UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
          CALL SetupOutputVariable('Unitary System Heating Ancillary Electric Energy [J]', &
                  UnitarySystem(UnitarySysNum)%HeatingAuxElecConsumption,'System','Sum',UnitarySystem(UnitarySysNum)%Name, &
                  ResourceTypeKey='Electric',EndUseKey='Heating',GroupKey='System')
        END IF

        SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)
          CASE(CoilDX_CoolingTwoSpeed)
            CALL SetupOutputVariable('Unitary System Cycling Ratio []',UnitarySystem(UnitarySysNum)%CycRatio, &
                                'System','Average',UnitarySystem(UnitarySysNum)%Name)
            CALL SetupOutputVariable('Unitary System Compressor Speed Ratio []',UnitarySystem(UnitarySysNum)%SpeedRatio, &
                                'System','Average',UnitarySystem(UnitarySysNum)%Name)
          CASE(CoilDX_MultiSpeedCooling)
            CALL SetupOutputVariable('Unitary System Cooling Ancillary Electric Energy [J]', &
                     UnitarySystem(UnitarySysNum)%CoolingAuxElecConsumption,'System','Sum',UnitarySystem(UnitarySysNum)%Name, &
                     ResourceTypeKey='Electric',EndUseKey='Cooling',GroupKey='System')
            CALL SetupOutputVariable('Unitary System Electric Power [W]',UnitarySystem(UnitarySysNum)%ElecPower,&
                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
            CALL SetupOutputVariable('Unitary System Electric Energy [J]',UnitarySystem(UnitarySysNum)%ElecPowerConsumption, &
                                     'System','Sum',UnitarySystem(UnitarySysNum)%Name)
!            CALL SetupOutputVariable('Unitary System Cooling Coil Cycling Ratio []',UnitarySystem(UnitarySysNum)%CoolingCycRatio, &
!                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
!            CALL SetupOutputVariable('Unitary System Cooling Coil Speed Ratio []',UnitarySystem(UnitarySysNum)%CoolingSpeedRatio, &
!                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
!            CALL SetupOutputVariable('Unitary System Cooling Coil Speed Level []',UnitarySystem(UnitarySysNum)%CoolingSpeedNum, &
!                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
            IF (UnitarySystem(UnitarySysNum)%HeatRecActive) THEN
              CALL SetupOutputVariable('Unitary System Heat Recovery Rate [W]',UnitarySystem(UnitarySysNum)%HeatRecoveryRate, &
                      'System','Average',UnitarySystem(UnitarySysNum)%Name)
              CALL SetupOutputVariable('Unitary System Heat Recovery Inlet Temperature [C]', &
                      UnitarySystem(UnitarySysNum)%HeatRecoveryInletTemp,'System','Average',UnitarySystem(UnitarySysNum)%Name)
              CALL SetupOutputVariable('Unitary System Heat Recovery Outlet Temperature [C]', &
                      UnitarySystem(UnitarySysNum)%HeatRecoveryOutletTemp,'System','Average',UnitarySystem(UnitarySysNum)%Name)
              CALL SetupOutputVariable('Unitary System Heat Recovery Fluid Mass Flow Rate [kg/s]', &
                      UnitarySystem(UnitarySysNum)%HeatRecoveryMassFlowRate,'System','Average',UnitarySystem(UnitarySysNum)%Name)
              CALL SetupOutputVariable('Unitary System Heat Recovery Energy [J]', &
                      UnitarySystem(UnitarySysNum)%HeatRecoveryEnergy,'System','Sum',UnitarySystem(UnitarySysNum)%Name)
            END IF
          CASE (Coil_CoolingAirToAirVariableSpeed, Coil_CoolingWaterToAirHPVSEquationFit, &
                Coil_CoolingWaterToAirHPSimple, Coil_CoolingWaterToAirHP)
            CALL SetupOutputVariable('Unitary System Requested Sensible Cooling Rate [W]', &
                                  UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand, &
                                  'System','Average',UnitarySystem(UnitarySysNum)%Name)
            CALL SetupOutputVariable('Unitary System Requested Latent Cooling Rate [W]', &
                                  UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand, &
                                  'System','Average',UnitarySystem(UnitarySysNum)%Name)
          CASE DEFAULT
        END SELECT

        SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)
          CASE(CoilDX_MultiSpeedHeating, Coil_HeatingElectric_MultiStage, Coil_HeatingGas_MultiStage)
!            CALL SetupOutputVariable('Unitary System Heating Coil Cycling Ratio []', &
!                                      UnitarySystem(UnitarySysNum)%HeatingCycRatio, &
!                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
!            CALL SetupOutputVariable('Unitary System Heating Coil Speed Ratio []', &
!                                      UnitarySystem(UnitarySysNum)%HeatingSpeedRatio, &
!                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
!            CALL SetupOutputVariable('Unitary System Heating Coil Speed Level []', &
!                                      UnitarySystem(UnitarySysNum)%HeatingSpeedNum, &
!                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
          CASE (Coil_HeatingAirToAirVariableSpeed, Coil_HeatingWaterToAirHPVSEquationFit, &
                Coil_HeatingWaterToAirHPSimple, Coil_HeatingWaterToAirHP)
            CALL SetupOutputVariable('Unitary System Requested Heating Rate [W]', &
                                      UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand, &
                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
          CASE DEFAULT
        END SELECT

        IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling .OR. &
           UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_MultiSpeedHeating .OR. &
           UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingElectric_MultiStage .OR. &
           UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingGas_MultiStage) THEN
            CALL SetupOutputVariable('Unitary System DX Coil Cycling Ratio []',UnitarySystem(UnitarySysNum)%CycRatio, &
                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
            CALL SetupOutputVariable('Unitary System DX Coil Speed Ratio []',UnitarySystem(UnitarySysNum)%SpeedRatio, &
                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
            CALL SetupOutputVariable('Unitary System DX Coil Speed Level []',UnitarySystem(UnitarySysNum)%SpeedNum, &
                                     'System','Average',UnitarySystem(UnitarySysNum)%Name)
        END IF

        IF (AnyEnergyManagementSystemInModel) THEN
          CALL SetupEMSActuator('AirLoopHVAC:UnitarySystem', UnitarySystem(UnitarySysNum)%Name,   &
                                'Autosized Supply Air Flow Rate', '[m3/s]',                          &
                                UnitarySystem(UnitarySysNum)%DesignFanVolFlowRateEMSOverrideOn,   &
                                UnitarySystem(UnitarySysNum)%DesignFanVolFlowRateEMSOverrideValue )
          CALL SetupEMSActuator('AirLoopHVAC:UnitarySystem', UnitarySystem(UnitarySysNum)%Name,   &
                                'Autosized Supply Air Flow Rate During Cooling Operation', '[m3/s]', &
                                UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlowEMSOverrideOn,      &
                                UnitarySystem(UnitarySysNum)%MaxCoolAirVolFlowEMSOverrideValue )
          CALL SetupEMSActuator('AirLoopHVAC:UnitarySystem', UnitarySystem(UnitarySysNum)%Name,   &
                                'Autosized Supply Air Flow Rate During Heating Operation', '[m3/s]', &
                                UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlowEMSOverrideOn,      &
                                UnitarySystem(UnitarySysNum)%MaxHeatAirVolFlowEMSOverrideValue )
          CALL SetupEMSActuator('AirLoopHVAC:UnitarySystem', UnitarySystem(UnitarySysNum)%Name,   &
                                'Autosized Supply Air Flow Rate During No Heating or Cooling Operation', '[m3/s]', &
                                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlowEMSOverrideOn, &
                                UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirVolFlowEMSOverrideValue )
        END IF

      END DO

      DEALLOCATE(Alphas)
      DEALLOCATE(cAlphaFields)
      DEALLOCATE(cNumericFields)
      DEALLOCATE(Numbers)
      DEALLOCATE(lAlphaBlanks)
      DEALLOCATE(lNumericBlanks)

      IF (AnyEnergyManagementSystemInModel) THEN
        DO UnitarySysNum = 1, NumUnitarySystem
          CALL SetupEMSInternalVariable('Unitary HVAC Design Heating Capacity', UnitarySystem(UnitarySysNum)%Name, '[W]', &
                        UnitarySystem(UnitarySysNum)%DesignHeatingCapacity  )
          CALL SetupEMSInternalVariable('Unitary HVAC Design Cooling Capacity', UnitarySystem(UnitarySysNum)%Name, '[W]', &
                        UnitarySystem(UnitarySysNum)%DesignCoolingCapacity  )
          CALL SetupEMSActuator('Unitary HVAC', UnitarySystem(UnitarySysNum)%Name, 'Sensible Load Request' , '[W]', &
                        UnitarySystem(UnitarySysNum)%EMSOverrideSensZoneLoadRequest, &
                        UnitarySystem(UnitarySysNum)%EMSSensibleZoneLoadValue )
          CALL SetupEMSActuator('Unitary HVAC', UnitarySystem(UnitarySysNum)%Name, 'Moisture Load Request' , '[W]', &
                        UnitarySystem(UnitarySysNum)%EMSOverrideMoistZoneLoadRequest, &
                        UnitarySystem(UnitarySysNum)%EMSMoistureZoneLoadValue )

        END DO
      END IF

      CALL ManageEMS(emsCALLFromComponentGetInput)


  RETURN

END SUBROUTINE GetUnitarySystemInput


! End of Get Input subroutines for the Module
!******************************************************************************


! Beginning of Calculation subroutines for the DXCoolingSystem Module
! *****************************************************************************

SUBROUTINE ControlUnitarySystemtoSP(UnitarySysNum, FirstHVACIteration, AirLoopNum,OAUCoilOutTemp,HXUnitOn)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine manages DXCoolingSystem component simulation.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE Fans,             ONLY: SimulateFanComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)          :: UnitarySysNum       ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL, INTENT(IN)          :: FirstHVACIteration  ! True when first HVAC iteration
  INTEGER, INTENT(IN)          :: AirLoopNum          ! Primary air loop number
  REAL(r64), INTENT(IN), OPTIONAL :: OAUCoilOutTemp   ! the coil inlet temperature of OutdoorAirUnit
  LOGICAL, INTENT(INOUT), OPTIONAL :: HXUnitOn        ! Flag to control HX for HXAssisted Cooling Coil

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  REAL(R64)                     :: PartLoadRatio         ! coil operating part-load ratio
  REAL(R64)                     :: OnOffAirFlowRatio     ! Setpoint based coil control does not use this variable
  REAL(R64)                     :: CoilCoolHeatRat       ! ratio of cooling to heating PLR for cycling fan RH control
  INTEGER                       :: CompOn                ! compressor control (0=off, 1=on)

  OnOffAirFlowRatio = 1.0d0
  CoilCoolHeatRat   = 1.0d0

  !CALL the series of components that simulate a Unitary System
  IF (UnitarySystem(UnitarySysNum)%FanExists .AND. UnitarySystem(UnitarySysNum)%FanPlace .EQ. BlowThru) THEN
    CALL SimulateFanComponents(Blank,FirstHVACIteration,UnitarySystem(UnitarySysNum)%FanIndex,FanSpeedRatio)
  END IF

  IF(UnitarySystem(UnitarySysNum)%CoolingCoilUpstream)THEN

    IF (UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
      CALL UpdateUnitarySystemControl(UnitarySysNum,AirLoopNum, &
                            UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum, &
                            UnitarySystem(UnitarySysNum)%SystemCoolControlNodeNum, &
                            OnOffAirFlowRatio,OAUCoilOutTemp,FirstHVACIteration)
      CALL ControlCoolingSystem(UnitarySysNum, FirstHVACIteration, HXUnitOn)
      PartLoadRatio = UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac
      CompOn = 0
      IF(PartLoadRatio > 0.0d0)CompOn = 1
      CALL CalcUnitaryCoolingSystem(UnitarySysNum,FirstHVACIteration,PartLoadRatio, &
                                    CompOn,OnOffAirFlowRatio,CoilCoolHeatRat,HXUnitOn)
    END IF
    IF (UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
      CALL UpdateUnitarySystemControl(UnitarySysNum,AirLoopNum, &
                            UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum, &
                            UnitarySystem(UnitarySysNum)%SystemHeatControlNodeNum, &
                            OnOffAirFlowRatio,OAUCoilOutTemp,FirstHVACIteration, &
                            MaxOutletTemp=UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp)
      CALL ControlHeatingSystem(UnitarySysNum, FirstHVACIteration)
      PartLoadRatio = UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac
      CompOn = 0
      IF(PartLoadRatio > 0.0d0)CompOn = 1
      CALL CalcUnitaryHeatingSystem(UnitarySysNum,FirstHVACIteration,PartLoadRatio, CompOn, OnOffAirFlowRatio)
    END IF

  ELSE

    IF (UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
      CALL UpdateUnitarySystemControl(UnitarySysNum,AirLoopNum, &
                            UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum, &
                            UnitarySystem(UnitarySysNum)%SystemHeatControlNodeNum, &
                            OnOffAirFlowRatio,OAUCoilOutTemp,FirstHVACIteration, &
                            MaxOutletTemp=UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp)
      CALL ControlHeatingSystem(UnitarySysNum, FirstHVACIteration)
      PartLoadRatio = UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac
      CompOn = 0
      IF(PartLoadRatio > 0.0d0)CompOn = 1
      CALL CalcUnitaryHeatingSystem(UnitarySysNum,FirstHVACIteration,PartLoadRatio, CompOn, OnOffAirFlowRatio)
    END IF
    IF (UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
      CALL UpdateUnitarySystemControl(UnitarySysNum,AirLoopNum, &
                            UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum, &
                            UnitarySystem(UnitarySysNum)%SystemCoolControlNodeNum, &
                            OnOffAirFlowRatio,OAUCoilOutTemp,FirstHVACIteration)
      CALL ControlCoolingSystem(UnitarySysNum, FirstHVACIteration, HXUnitOn)
      PartLoadRatio = UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac
      CompOn = 0
      IF(PartLoadRatio > 0.0d0)CompOn = 1
      CALL CalcUnitaryCoolingSystem(UnitarySysNum,FirstHVACIteration,PartLoadRatio, &
                                    CompOn,OnOffAirFlowRatio,CoilCoolHeatRat,HXUnitOn)
    END IF

  END IF

  IF (UnitarySystem(UnitarySysNum)%FanExists .AND. UnitarySystem(UnitarySysNum)%FanPlace .EQ. DrawThru) THEN
    CALL SimulateFanComponents(Blank,FirstHVACIteration,UnitarySystem(UnitarySysNum)%FanIndex,FanSpeedRatio)
  END IF

  IF (UnitarySystem(UnitarySysNum)%SuppCoilExists)THEN
    SuppHeatingCoilFlag = .TRUE.
    CALL UpdateUnitarySystemControl(UnitarySysNum,AirLoopNum, &
                          UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode, &
                          UnitarySystem(UnitarySysNum)%SuppHeatControlNodeNum, &
                          OnOffAirFlowRatio,OAUCoilOutTemp,FirstHVACIteration, &
                          MaxOutletTemp=UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp)
    CALL ControlSuppHeatSystem(UnitarySysNum, FirstHVACIteration)
    CALL CalcUnitarySuppSystemToSP(UnitarySysNum,FirstHVACIteration)
    SuppHeatingCoilFlag = .FALSE.
  END IF


  UnitarySystem(UnitarySysNum)%InitHeatPump = .FALSE.
  RETURN

END SUBROUTINE ControlUnitarySystemtoSP

SUBROUTINE ControlUnitarySystemtoLoad(UnitarySysNum, FirstHVACIteration, AirLoopNum,CompOn,OAUCoilOutTemp,HXUnitOn)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine manages DXCoolingSystem component simulation.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DataAirLoop, ONLY: AirLoopControlInfo
  USE PlantUtilities,    ONLY: SetComponentFlowRate

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)              :: UnitarySysNum    ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL, INTENT(IN)              :: FirstHVACIteration  ! True when first HVAC iteration
  INTEGER, INTENT(IN)              :: AirLoopNum          ! Primary air loop number
  INTEGER, INTENT(INOUT)           :: CompOn              ! Determines if compressor is on or off
  REAL(r64), INTENT(IN),  OPTIONAL :: OAUCoilOutTemp      ! the coil inlet temperature of OutdoorAirUnit
  LOGICAL, INTENT(INOUT), OPTIONAL :: HXUnitOn            ! Flag to control HX for HXAssisted Cooling Coil

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DEFINITIONS:
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  REAL(R64)                     :: CoolPLR          ! cooling part-load ratio
  REAL(R64)                     :: HeatPLR          ! heating part-load ratio
  REAL(R64)                     :: SuppPLR          ! supplemental heating part-load ratio
  REAL(R64)                     :: SensOutput       ! Sensible output of Unitary System (W)
  REAL(R64)                     :: LatOutput        ! Latent output of Unitary System (W)
  REAL(R64)                     :: ZoneLoad           ! zone load (W)
  REAL(R64)                     :: OnOffAirFlowRatio  ! ratio of on to off air flow
  REAL(R64)                     :: QZnReq             ! zone load (W)
  REAL(R64)                     :: FullSensibleOutput ! sensible output of Unitary System (W)
!  REAL(R64)                     :: FullLatentOutput   ! latent output of Unitary System (W)
  REAL(R64)                     :: SupHeaterLoad    ! additional heating required by supplemental heater (W)
  REAL(r64)                     :: HeatCoilLoad     ! load pass to heating coil (W)

  OnOffAirFlowRatio = 1.0d0
  QZnReq = 0.0d0
  CALL UpdateUnitarySystemControl(UnitarySysNum,AirLoopNum, &
                            UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum, &
                            UnitarySystem(UnitarySysNum)%SystemCoolControlNodeNum, OnOffAirFlowRatio, &
                            OAUCoilOutTemp, FirstHVACIteration, ZoneLoad)

! will not be running supplemental heater on this CALL (simulate with supplemental heater off)
  FullSensibleOutput = 0.0d0
  ! using furnace module logic
  ! first check to see if cycling fan with economizer can meet the load
  IF(AirLoopNum > 0)THEN
    IF ( UnitarySystem(UnitarySysNum)%CoolCoilExists .AND. UnitarySystem(UnitarySysNum)%HeatCoilExists .AND. &
        UnitarySystem(UnitarySysNum)%CoolingCoilType_Num /= Coil_CoolingAirToAirVariableSpeed .AND. &
        UnitarySystem(UnitarySysNum)%HeatingCoilType_Num /= Coil_HeatingAirToAirVariableSpeed .AND. &
        .NOT. FirstHVACIteration .AND. UnitarySystem(UnitarySysNum)%FanOpMode == CycFanCycCoil .AND. CoolingLoad &
         .AND. AirLoopControlInfo(AirLoopNum)%EconoActive) THEN
      CompOn=0
      CALL ControlUnitarySystemOutput(UnitarySysNum, FirstHVACIteration, OnOffAirFlowRatio, &
                                    HXUnitOn, ZoneLoad, FullSensibleOutput, CompOn)
      IF (UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac >= 1.0d0 .OR. UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac >= 1.0d0 &
           .OR. (UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac <= 0.0d0 .AND. &
                 UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac <= 0.0d0)) THEN
        CompOn=1
        CALL ControlUnitarySystemOutput(UnitarySysNum, FirstHVACIteration, OnOffAirFlowRatio, &
                                      HXUnitOn, ZoneLoad, FullSensibleOutput, CompOn)
      END IF
    ELSE
      CompOn = 1
      CALL ControlUnitarySystemOutput(UnitarySysNum, FirstHVACIteration, OnOffAirFlowRatio, &
                                  HXUnitOn, ZoneLoad, FullSensibleOutput, CompOn)
    END IF
  ELSE
    CompOn = 1
    CALL ControlUnitarySystemOutput(UnitarySysNum, FirstHVACIteration, OnOffAirFlowRatio, &
                                  HXUnitOn, ZoneLoad, FullSensibleOutput, CompOn)
  END IF
  CoolPLR = UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac
  HeatPLR = UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac
  HeatCoilLoad = HeatPLR * UnitarySystem(UnitarySysNum)%DesignHeatingCapacity
  SensOutput = 0.0d0
  LatOutput  = 0.0d0

  IF(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode .GT. 0)THEN
    CALL SetComponentFlowRate( Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode)%MassFlowRate, &
                               UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode,  &
                               UnitarySystem(UnitarySysNum)%CoolCoilFluidOutletNodeNum,&
                               UnitarySystem(UnitarySysNum)%CoolCoilLoopNum, &
                               UnitarySystem(UnitarySysNum)%CoolCoilLoopSide, &
                               UnitarySystem(UnitarySysNum)%CoolCoilBranchNum, &
                               UnitarySystem(UnitarySysNum)%CoolCoilCompNum )
  END IF
  IF(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode .GT. 0)THEN
    CALL SetComponentFlowRate( Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode)%MassFlowRate, &
                               UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode,  &
                               UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum,&
                               UnitarySystem(UnitarySysNum)%HeatCoilLoopNum, &
                               UnitarySystem(UnitarySysNum)%HeatCoilLoopSide, &
                               UnitarySystem(UnitarySysNum)%HeatCoilBranchNum, &
                               UnitarySystem(UnitarySysNum)%HeatCoilCompNum )
  END IF

  IF (UnitarySystem(UnitarySysNum)%SuppCoilExists .AND. (HeatingLoad .OR. CoolingLoad .OR. MoistureLoad<0.0d0)) THEN
    IF((FullSensibleOutput < (QToHeatSetPt - SmallLoad)) .AND. .NOT. FirstHVACIteration)THEN
      SupHeaterLoad = MAX(0.0d0,QToHeatSetPt - FullSensibleOutput)
      UnitarySystem(UnitarySysNum)%SupHeaterLoad = 0.0d0
! what does this line even do? I know we want the supplemental heater on only if there is a dehum load,
! but for HP's the supp heater should also run if the heating coil can't turn on
! (i.e., this line calc's a supp heater load, then next line also calc's it?)
      IF (MoistureLoad < 0.0d0) &
        UnitarySystem(UnitarySysNum)%SupHeaterLoad = SupHeaterLoad
! so it look's like this next line should only be valid for HP's.
      IF(UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity .GT. 0.0d0)THEN
        UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac = &
             MIN(1.0d0,SupHeaterLoad/UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity)
      END IF
    ELSE
      SupHeaterLoad = 0.0d0
      UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac = 0.0d0
    END IF
  ELSE
    SupHeaterLoad = 0.0d0
    UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac = 0.0d0
  END IF

  CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
         OnOffAirFlowRatio,SensOutput,LatOutput,HXUnitOn,HeatCoilLoad=HeatCoilLoad, &
         SuppCoilLoad=SupHeaterLoad,CompOn=CompOn)

  ! check supplemental heating coil outlet temp based on maximum allowed
  IF(UnitarySystem(UnitarySysNum)%SuppCoilExists)THEN
    SuppPLR = UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac
    ! only need to test for high supply air temp if supplemental coil is operating
    IF(SuppPLR > 0.0d0)THEN
      CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR,OnOffAirFlowRatio, &
             SensOutput,LatOutput,HXUnitOn,HeatCoilLoad=HeatCoilLoad,SuppCoilLoad=SupHeaterLoad, CompOn=CompOn)
      IF(UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity .GT. 0.0d0)THEN
        UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac = SupHeaterLoad/UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity
      ELSE
        UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac = 0.0d0
      END IF
    END IF
  END IF

  IF(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode .GT. 0)THEN
    CALL SetComponentFlowRate( Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode)%MassFlowRate, &
                               UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode,  &
                               UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum,&
                               UnitarySystem(UnitarySysNum)%SuppCoilLoopNum, &
                               UnitarySystem(UnitarySysNum)%SuppCoilLoopSide, &
                               UnitarySystem(UnitarySysNum)%SuppCoilBranchNum, &
                               UnitarySystem(UnitarySysNum)%SuppCoilCompNum )
  END IF

  IF (UnitarySystem(UnitarySysNum)%HeatRecActive) THEN
    CALL SetComponentFlowRate(Node(UnitarySystem(UnitarySysNum)%HeatRecoveryInletNodeNum)%MassFlowRate, &
                              UnitarySystem(UnitarySysNum)%HeatRecoveryInletNodeNum, &
                              UnitarySystem(UnitarySysNum)%HeatRecoveryOutletNodeNum, &
                              UnitarySystem(UnitarySysNum)%HRLoopNum, &
                              UnitarySystem(UnitarySysNum)%HRLoopSideNum, &
                              UnitarySystem(UnitarySysNum)%HRBranchNum, &
                              UnitarySystem(UnitarySysNum)%HRCompNum )
  END IF

  RETURN

END SUBROUTINE ControlUnitarySystemtoLoad

SUBROUTINE ControlUnitarySystemOutput(UnitarySysNum, FirstHVACIteration, OnOffAirFlowRatio, HXUnitOn, &
                                      ZoneLoad, FullSensibleOutput, CompOn)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine determines operating PLR and calculates the load based system output.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE General,           ONLY: SolveRegulaFalsi, TrimSigDigits
  USE DataHeatBalFanSys, ONLY: TempControlType
  USE Psychrometrics,    ONLY: PsyCpAirFnWTdb

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)              :: UnitarySysNum    ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL, INTENT(IN)              :: FirstHVACIteration  ! True when first HVAC iteration
  REAL(R64), INTENT(INOUT)         :: OnOffAirFlowRatio   ! ratio of heating PLR to cooling PLR (is this correct?)
  LOGICAL, INTENT(INOUT), OPTIONAL :: HXUnitOn            ! Flag to control HX for HXAssisted Cooling Coil
  REAL(R64), INTENT(IN)            :: ZoneLoad
  REAL(R64), INTENT(INOUT)         :: FullSensibleOutput
  INTEGER, OPTIONAL, INTENT(INOUT) :: CompOn

          ! SUBROUTINE PARAMETER DEFINITIONS:
  INTEGER,   PARAMETER  ::  MaxIter = 100        ! maximum number of iterations
  REAL(r64), PARAMETER  ::  MinPLR  = 0.0d0      ! minimum part load ratio allowed

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DEFINITIONS:
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName           ! Name of Unitary System object
  INTEGER                       :: InletNode          ! DX System inlet node number
  INTEGER                       :: OutletNode         ! DX System outlet node number
  INTEGER                       :: OpMode             ! fan operating mode (cycling or constant)
  REAL(R64)                     :: PartLoadRatio      ! operating part-load ratio
  REAL(R64)                     :: SensOutputOff      ! sensible output at PLR = 0 [W]
  REAL(R64)                     :: LatOutputOff       ! latent output at PLR = 0 [W]
  REAL(R64)                     :: SensOutputOn       ! sensible output at PLR = 1 [W]
  REAL(R64)                     :: LatOutputOn        ! latent output at PLR = 1 [W]
  REAL(R64)                     :: CoolPLR            ! cooing part load ratio
  REAL(R64)                     :: HeatPLR            ! heating part load ratio
  REAL(r64), DIMENSION(10)      :: Par                ! parameters passed to RegulaFalsi function
  INTEGER                       :: SolFlag            ! return flag from RegulaFalsi for sensible load
  INTEGER                       :: SolFlagLat         ! return flag from RegulaFalsi for latent load
  REAL(r64)                     :: TempLoad           ! represents either a sensible or latent load [W]
  REAL(r64)                     :: TempSysOutput      ! represents either a sensible or latent capacity [W]
  REAL(R64)                     :: TempSensOutput     ! iterative sensible capacity [W]
  REAL(R64)                     :: TempLatOutput      ! iterative latent capacity [W]
  REAL(R64)                     :: TempMinPLR         ! iterative minimum PLR
  REAL(R64)                     :: TempMaxPLR         ! iterative maximum PLR
  INTEGER                       :: SpeedNum           ! multi-speed coil speed number
  INTEGER                       :: CompressorONFlag   ! 0= compressor off, 1= compressor off
  REAL(r64)                     :: CoolingOnlySensibleOutput ! use to calculate dehumidification induced heating [W]
  REAL(r64)                     :: CpAir                     ! specific heat of air [J/kg_C]

  CompName = UnitarySystem(UnitarySysNum)%Name
  InletNode = UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum
  OutletNode = UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum
  OpMode = UnitarySystem(UnitarySysNum)%FanOpMode
  ! Pass full mass flow rate on FirstHVACIteration to set MassFlowRateMax
  IF(FirstHVACIteration .AND. UnitarySystem(UnitarySysNum)%AirLoopEquipment)THEN
    IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingSingleSpeed .OR. &
        UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingHXAssisted .OR. &
        UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == CoilDX_HeatingEmpirical .OR. &
        UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingAirToAirVariableSpeed .OR. &
        UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingAirToAirVariableSpeed .OR. &
        UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHPSimple .OR. &
        UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple) THEN
      PartLoadRatio = 1.0d0
      IF(HeatingLoad)THEN
        UnitarySystem(UnitarySysNum)%HeatingSpeedNum = UnitarySystem(UnitarySysNum)%NumOfSpeedHeating
        UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 1.0d0
      ELSE
!        CoolingLoad = .TRUE.
        UnitarySystem(UnitarySysNum)%CoolingSpeedNum = UnitarySystem(UnitarySysNum)%NumOfSpeedCooling
        UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 1.0d0
      END IF
    ELSE
      IF(HeatingLoad)THEN
        PartLoadRatio = 0.0d0
        UnitarySystem(UnitarySysNum)%HeatingSpeedNum = UnitarySystem(UnitarySysNum)%NumOfSpeedHeating
        UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 1.0d0
        IF (UnitarySystem(UnitarySysNum)%Staged .AND. ABS(UnitarySystem(UnitarySysNum)%StageNum) .LT. &
            UnitarySystem(UnitarySysNum)%NumOfSpeedHeating) THEN
          UnitarySystem(UnitarySysNum)%HeatingSpeedNum = ABS(UnitarySystem(UnitarySysNum)%StageNum)
          IF (UnitarySystem(UnitarySysNum)%HeatingSpeedNum == 1) UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 0.0d0
        END IF
      ELSE
!        CoolingLoad = .TRUE.
        PartLoadRatio = 1.0d0
        UnitarySystem(UnitarySysNum)%CoolingSpeedNum = UnitarySystem(UnitarySysNum)%NumOfSpeedCooling
        UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 1.0d0
        IF (UnitarySystem(UnitarySysNum)%Staged .AND. ABS(UnitarySystem(UnitarySysNum)%StageNum) .LT. &
            UnitarySystem(UnitarySysNum)%NumOfSpeedCooling) THEN
          UnitarySystem(UnitarySysNum)%CoolingSpeedNum = ABS(UnitarySystem(UnitarySysNum)%StageNum)
          IF (UnitarySystem(UnitarySysNum)%CoolingSpeedNum == 1) UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
        END IF
      END IF
    END IF
    CALL SetOnOffMassFlowRate(UnitarySysNum, OnOffAirFlowRatio, PartLoadRatio)
    IF(HeatingLoad)THEN
      UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac=1.0d0
    ELSE
      UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac=1.0d0
    END IF
    CompOn=0
    RETURN
  END IF

  IF(GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%SysAvailSchedPtr) .LE. 0.0d0)THEN
    RETURN
  END IF

  PartLoadRatio = 0.0d0   ! Get no load result
  SolFlag = 0    ! # of iterations IF positive, -1 means failed to converge, -2 means bounds are incorrect
  SolFlagLat = 0    ! # of iterations IF positive, -1 means failed to converge, -2 means bounds are incorrect

  SensOutputOff = 0.0d0
  LatOutputOff  = 0.0d0
  CoolPLR       = 0.0d0
  HeatPLR       = 0.0d0
  CompressorONFlag = 0

  UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac   = 0.0d0

  CALL SetOnOffMassFlowRate(UnitarySysNum, OnOffAirFlowRatio, PartLoadRatio)

  IF (HeatingLoad) THEN
    UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand   = ZoneLoad
    UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand   = 0.0d0
    UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand = 0.0d0
  ELSE IF(CoolingLoad .OR. MoistureLoad < 0.0d0)THEN
    UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand   = 0.0d0
    IF(CoolingLoad)THEN
      UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand   = ABS(ZoneLoad)
    ELSE
      UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand   = 0.0d0
    END IF
    UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand = ABS(MoistureLoad)
  ELSE
    RETURN
  END IF

  CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                               OnOffAirFlowRatio,SensOutputOff,LatOutputOff,HXUnitOn,CompOn=CompressorONFlag)
  FullSensibleOutput = SensOutputOff

  IF(.NOT. HeatingLoad .AND. .NOT. CoolingLoad) THEN
    ! no load
    IF(MoistureLoad >= 0.0d0 .OR. MoistureLoad > LatOutputOff) RETURN
    ! Dehumcontrol_Multimode only controls RH if there is a sensible load
    IF(UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_Multimode) RETURN
  END IF

! determine if PLR=0 meets the load
  SELECT CASE (TempControlType(UnitarySystem(UnitarySysNum)%ControlZoneNum))
    CASE(SingleHeatingSetPoint)
      IF(HeatingLoad .AND. SensOutputOff .GT. ZoneLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
      IF(.NOT. HeatingLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
    CASE(SingleCoolingSetPoint)
      IF(CoolingLoad .AND. SensOutputOff .LT. ZoneLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
      IF(.NOT. CoolingLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
    CASE(SingleHeatCoolSetPoint, DualSetPointWithDeadBand)
      IF(HeatingLoad .AND. SensOutputOff .GT. ZoneLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
      IF(CoolingLoad .AND. SensOutputOff .LT. ZoneLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
      IF(.NOT. HeatingLoad .AND. .NOT. CoolingLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
    CASE DEFAULT
      ! should never get here
  END SELECT

! if a variable speed unit, the SensOutputOff at SpeedNum=1 must be checked to see if it exceeds the ZoneLoad
! This is still no load but at the first speed above idle
  IF(HeatingLoad .AND. UnitarySystem(UnitarySysNum)%NumOfSpeedHeating > 0 .OR. &
     CoolingLoad .AND. UnitarySystem(UnitarySysNum)%NumOfSpeedCooling > 0)THEN
    IF(UnitarySystem(UnitarySysNum)%Staged)THEN
      IF(HeatingLoad)THEN
        UnitarySystem(UnitarySysNum)%HeatingSpeedNum   = UnitarySystem(UnitarySysNum)%StageNum
      ELSE
        UnitarySystem(UnitarySysNum)%CoolingSpeedNum   = ABS(UnitarySystem(UnitarySysNum)%StageNum)
      END IF
    ELSE
      IF(HeatingLoad)THEN
        UnitarySystem(UnitarySysNum)%HeatingSpeedNum   = 1
      ELSE
        UnitarySystem(UnitarySysNum)%CoolingSpeedNum   = 1
      END IF
    END IF
    CALL SetOnOffMassFlowRate(UnitarySysNum, OnOffAirFlowRatio, PartLoadRatio)
    CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                                 OnOffAirFlowRatio,SensOutputOff,LatOutputOff,HXUnitOn,CompOn=CompressorONFlag)
    FullSensibleOutput = SensOutputOff

    SELECT CASE (TempControlType(UnitarySystem(UnitarySysNum)%ControlZoneNum))
      CASE(SingleHeatingSetPoint)
        IF(HeatingLoad .AND. SensOutputOff .GT. ZoneLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
        IF(.NOT. HeatingLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
      CASE(SingleCoolingSetPoint)
        IF(CoolingLoad .AND. SensOutputOff .LT. ZoneLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
        IF(.NOT. CoolingLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
      CASE(SingleHeatCoolSetPoint, DualSetPointWithDeadBand)
        IF(HeatingLoad .AND. SensOutputOff .GT. ZoneLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
        IF(CoolingLoad .AND. SensOutputOff .LT. ZoneLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
        IF(.NOT. HeatingLoad .AND. .NOT. CoolingLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad .GT. LatOutputOff))RETURN
      CASE DEFAULT
      ! should never get here
    END SELECT
  END IF

  PartLoadRatio = 1.0d0  ! Get full load result
  IF(PRESENT(CompOn))THEN
    CompressorONFlag = CompOn
  ELSE
    CompressorONFlag = 1
  END IF

  IF(HeatingLoad)THEN
    CoolPLR       = 0.0d0
    HeatPLR       = 1.0d0
    UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 1.0d0
    UnitarySystem(UnitarySysNum)%HeatingCycRatio = 1.0d0
    UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac   = HeatPLR
    UnitarySystem(UnitarySysNum)%HeatingSpeedNum = UnitarySystem(UnitarySysNum)%NumOfSpeedHeating
    IF (UnitarySystem(UnitarySysNum)%Staged .AND. UnitarySystem(UnitarySysNum)%StageNum > 0) THEN
      UnitarySystem(UnitarySysNum)%HeatingSpeedNum = MIN(UnitarySystem(UnitarySysNum)%StageNum, &
                                                         UnitarySystem(UnitarySysNum)%NumOfSpeedHeating)
      CALL SetOnOffMassFlowRate(UnitarySysNum, OnOffAirFlowRatio, PartLoadRatio)
      UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 0.0d0
      CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                         OnOffAirFlowRatio,SensOutputOff,LatOutputOff,HXUnitOn,CompOn=CompressorONFlag)
      IF(SensOutputOff .GT. ZoneLoad)RETURN
      UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 1.0d0
    END IF
  ELSEIF(CoolingLoad .OR. MoistureLoad < LatOutputOff)THEN
    CoolPLR       = 1.0d0
    HeatPLR       = 0.0d0
    UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 1.0d0
    UnitarySystem(UnitarySysNum)%CoolingCycRatio   = 1.0d0
    UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac   = CoolPLR
    UnitarySystem(UnitarySysNum)%CoolingSpeedNum = UnitarySystem(UnitarySysNum)%NumOfSpeedCooling
    IF (UnitarySystem(UnitarySysNum)%Staged .AND. UnitarySystem(UnitarySysNum)%StageNum < 0) THEN
      UnitarySystem(UnitarySysNum)%CoolingSpeedNum = MIN(ABS(UnitarySystem(UnitarySysNum)%StageNum), &
                                                         UnitarySystem(UnitarySysNum)%NumOfSpeedCooling)
      CALL SetOnOffMassFlowRate(UnitarySysNum, OnOffAirFlowRatio, PartLoadRatio)
      UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
      CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                         OnOffAirFlowRatio,SensOutputOff,LatOutputOff,HXUnitOn,CompOn=CompressorONFlag)
      IF(SensOutputOff .LT. ZoneLoad)RETURN
      UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 1.0d0
    END IF
  ELSE
    ! will return here when no cooling or heating load and MoistureLoad > LatOutputOff (i.e., PLR=0)
    RETURN
  END IF

  CALL SetOnOffMassFlowRate(UnitarySysNum, OnOffAirFlowRatio, PartLoadRatio)

  CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                         OnOffAirFlowRatio,SensOutputOn,LatOutputOn,HXUnitOn,CompOn=CompressorONFlag)
  FullSensibleOutput = SensOutputOn

  ! turn on HX if DehumidControl_Multimode
  IF(UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_Multimode .AND. &
     MoistureLoad < 0.0d0 .AND. MoistureLoad < LatOutputOn .AND. CoolingLoad)THEN
    HXUnitOn = .TRUE.
    CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                         OnOffAirFlowRatio,SensOutputOn,LatOutputOn,HXUnitOn,CompOn=CompressorONFlag)
    FullSensibleOutput = SensOutputOn
  END IF

  ! test to see if full capacity is less than load, if so set to PLR=1 and RETURN if no moisture load
  IF(HeatingLoad .AND. UnitarySystem(UnitarySysNum)%NumOfSpeedHeating .LE. 1 .OR. &
     CoolingLoad .AND. UnitarySystem(UnitarySysNum)%NumOfSpeedCooling .LE. 1)THEN
  SELECT CASE (TempControlType(UnitarySystem(UnitarySysNum)%ControlZoneNum))
    CASE(SingleHeatingSetPoint)
      IF(HeatingLoad .AND. SensOutputOn .LT. ZoneLoad)THEN
        UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac = 1.0d0
        UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac     = 1.0d0
        IF(MoistureLoad >= 0.0d0 .OR. (MoistureLoad < 0.0d0 .AND. MoistureLoad < LatOutputOn))RETURN
      END IF
      IF(.NOT. HeatingLoad .AND. &
         (MoistureLoad >= 0.0d0 .OR. (MoistureLoad < 0.0d0 .AND. MoistureLoad < LatOutputOn)))RETURN
    CASE(SingleCoolingSetPoint)
      IF(CoolingLoad .AND. SensOutputOn .GT. ZoneLoad)THEN
        UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac = 1.0d0
        UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac     = 1.0d0
        IF(MoistureLoad >= 0.0d0 .OR. (MoistureLoad < 0.0d0 .AND. MoistureLoad < LatOutputOn))RETURN
      END IF
      IF(.NOT. CoolingLoad .AND. &
        (MoistureLoad >= 0.0d0 .OR. (MoistureLoad < 0.0d0 .AND. MoistureLoad < LatOutputOn)))RETURN
    CASE(SingleHeatCoolSetPoint, DualSetPointWithDeadBand)
      IF(HeatingLoad .AND. SensOutputOn .LT. ZoneLoad)THEN
        UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac = 1.0d0
        UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac     = 1.0d0
        IF(MoistureLoad >= 0.0d0 .OR. (MoistureLoad < 0.0d0 .AND. MoistureLoad > LatOutputOn))THEN
          RETURN
        END IF
      END IF
      IF(CoolingLoad .AND. SensOutputOn .GT. ZoneLoad)THEN
        UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac = 1.0d0
        UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac     = 1.0d0
        RETURN
      END IF
      IF(.NOT. HeatingLoad .AND. .NOT. CoolingLoad .AND. &
        (MoistureLoad >= 0.0d0 .OR. (MoistureLoad < 0.0d0 .AND. MoistureLoad < LatOutputOn)))THEN
        RETURN
      END IF
  CASE DEFAULT
    ! no other choices for thermostat control
  END SELECT
  END IF
! will find speed for multispeed coils here and then RegulaFalsi on PLR at a fixed speed

! Do the non-variable or non-multispeed coils have a NumOfSpeed = 0 ? We don't need to do this for single speed coils.
! Check to see which speed to meet the load
  UnitarySystem(UnitarySysNum)%HeatingSpeedNum = 0
  UnitarySystem(UnitarySysNum)%CoolingSpeedNum = 0
  IF (.NOT. UnitarySystem(UnitarySysNum)%Staged) THEN
    IF(HeatingLoad)THEN
      DO SpeedNum=1,UnitarySystem(UnitarySysNum)%NumOfSpeedHeating
        CoolPLR       = 0.0d0
        HeatPLR       = 1.0d0
        IF(SpeedNum == 1)THEN
          UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 0.0d0
        ELSE
          UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 1.0d0
        END IF
        UnitarySystem(UnitarySysNum)%HeatingCycRatio = 1.0d0
        UnitarySystem(UnitarySysNum)%HeatingSpeedNum = SpeedNum
        CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                         OnOffAirFlowRatio,SensOutputOn,LatOutputOn,HXUnitOn,CompOn=CompressorONFlag)
        IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num /= Coil_HeatingWaterToAirHPVSEquationFit) THEN
          UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 0.0d0
          UnitarySystem(UnitarySysNum)%HeatingSpeedNum = SpeedNum-1
          IF(UnitarySystem(UnitarySysNum)%HeatingSpeedNum .EQ. 0)THEN
            UnitarySystem(UnitarySysNum)%HeatingCycRatio = 0.0d0
            HeatPLR = 0.0d0
          ELSE
            UnitarySystem(UnitarySysNum)%HeatingCycRatio = 1.0d0
            HeatPLR = 1.0d0
          END IF
          CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                       OnOffAirFlowRatio,SensOutputOff,LatOutputOff,HXUnitOn,CompOn=CompressorONFlag)
          UnitarySystem(UnitarySysNum)%HeatingSpeedNum = SpeedNum
        END IF
        IF (ZoneLoad <= SensOutputOn) THEN
          EXIT
        END IF
      END DO
    ELSE ! Cooling or moisture load
      DO SpeedNum=1,UnitarySystem(UnitarySysNum)%NumOfSpeedCooling
        CoolPLR       = 1.0d0
        HeatPLR       = 0.0d0
        IF(SpeedNum == 1)THEN
          UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
        ELSE
          UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 1.0d0
        END IF
        UnitarySystem(UnitarySysNum)%CoolingCycRatio = 1.0d0
        UnitarySystem(UnitarySysNum)%CoolingSpeedNum = SpeedNum
        CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR,OnOffAirFlowRatio, &
                                     SensOutputOn,LatOutputOn,HXUnitOn,CompOn=CompressorONFlag)

        IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num /= Coil_CoolingWaterToAirHPVSEquationFit) THEN
          UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
          UnitarySystem(UnitarySysNum)%CoolingSpeedNum = SpeedNum-1
          IF(UnitarySystem(UnitarySysNum)%CoolingSpeedNum .EQ. 0)THEN
            UnitarySystem(UnitarySysNum)%CoolingCycRatio = 0.0d0
            CoolPLR = 0.0d0
          ELSE
            UnitarySystem(UnitarySysNum)%CoolingCycRatio = 1.0d0
            CoolPLR = 1.0d0
          END IF
          CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR,OnOffAirFlowRatio, &
                                       SensOutputOff,LatOutputOff,HXUnitOn,CompOn=CompressorONFlag)
          UnitarySystem(UnitarySysNum)%CoolingSpeedNum = SpeedNum
          END IF
        IF (ZoneLoad >= SensOutputOn) THEN
          EXIT
        END IF
      END DO
    END IF
  ELSE ! IF (.NOT. UnitarySystem(UnitarySysNum)%Staged) THEN
  ! Staged control
   IF(HeatingLoad)THEN
      CoolPLR       = 0.0d0
      HeatPLR       = 1.0d0
      SpeedNum = UnitarySystem(UnitarySysNum)%StageNum
      IF(SpeedNum == 1)THEN
        UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 0.0d0
      ELSE
        UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 1.0d0
        SpeedNum = MIN(UnitarySystem(UnitarySysNum)%StageNum,UnitarySystem(UnitarySysNum)%NumOfSpeedHeating)
      END IF
      UnitarySystem(UnitarySysNum)%HeatingCycRatio = 1.0d0
      UnitarySystem(UnitarySysNum)%HeatingSpeedNum = SpeedNum
      CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                         OnOffAirFlowRatio,SensOutputOn,LatOutputOn,HXUnitOn,CompOn=CompressorONFlag)
      IF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num /= Coil_HeatingWaterToAirHPVSEquationFit) THEN
        UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 0.0d0
        UnitarySystem(UnitarySysNum)%HeatingSpeedNum = SpeedNum-1
        IF(UnitarySystem(UnitarySysNum)%HeatingSpeedNum .EQ. 0)THEN
          UnitarySystem(UnitarySysNum)%HeatingCycRatio = 0.0d0
          HeatPLR = 0.0d0
        ELSE
          UnitarySystem(UnitarySysNum)%HeatingCycRatio = 1.0d0
          HeatPLR = 1.0d0
        END IF
        CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                       OnOffAirFlowRatio,SensOutputOff,LatOutputOff,HXUnitOn,CompOn=CompressorONFlag)
        UnitarySystem(UnitarySysNum)%HeatingSpeedNum = SpeedNum
      END IF
      IF (ZoneLoad <= SensOutputOn) THEN
!        EXIT ????????????
      END IF
   ELSE ! Cooling or moisture load
      CoolPLR       = 1.0d0
      HeatPLR       = 0.0d0
      SpeedNum = ABS(UnitarySystem(UnitarySysNum)%StageNum)
      IF(SpeedNum == 1)THEN
        UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
      ELSE
        UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 1.0d0
        SpeedNum = MIN(ABS(UnitarySystem(UnitarySysNum)%StageNum),UnitarySystem(UnitarySysNum)%NumOfSpeedCooling)
      END IF
      UnitarySystem(UnitarySysNum)%CoolingCycRatio = 1.0d0
      UnitarySystem(UnitarySysNum)%CoolingSpeedNum = SpeedNum
      CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR,OnOffAirFlowRatio, &
                                   SensOutputOn,LatOutputOn,HXUnitOn,CompOn=CompressorONFlag)

      IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num /= Coil_CoolingWaterToAirHPVSEquationFit) THEN
        UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
        UnitarySystem(UnitarySysNum)%CoolingSpeedNum = SpeedNum-1
        IF(UnitarySystem(UnitarySysNum)%CoolingSpeedNum .EQ. 0)THEN
          UnitarySystem(UnitarySysNum)%CoolingCycRatio = 0.0d0
          CoolPLR = 0.0d0
        ELSE
          UnitarySystem(UnitarySysNum)%CoolingCycRatio = 1.0d0
          CoolPLR = 1.0d0
        END IF
        CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR,OnOffAirFlowRatio, &
                                     SensOutputOff,LatOutputOff,HXUnitOn,CompOn=CompressorONFlag)
        UnitarySystem(UnitarySysNum)%CoolingSpeedNum = SpeedNum
      END IF
      IF (ZoneLoad >= SensOutputOn) THEN
!        EXIT ???????????
      END IF
   END IF
  END IF ! IF (.NOT. UnitarySystem(UnitarySysNum)%Staged) THEN

  FullSensibleOutput = SensOutputOn

  IF(.NOT. HeatingLoad .AND. .NOT. CoolingLoad .AND. (MoistureLoad >= 0.0d0 .OR. MoistureLoad < LatOutputOn))THEN
    ! if no load, or only a moisture load which can't be met at PLR=1, RETURN
    RETURN
  END IF
  ! must test to see if load is bounded by capacity before calling RegulaFalsi
  IF((HeatingLoad .AND. ZoneLoad < SensOutputOn) .OR. (CoolingLoad .AND. ZoneLoad > SensOutputOn))THEN
    IF((HeatingLoad .AND. ZoneLoad > SensOutputOff) .OR. (CoolingLoad .AND. ZoneLoad < SensOutputOff))THEN
      Par(1)  = REAL(UnitarySysNum,r64)
      Par(2)  = 0.0d0  ! FLAG, IF 1.0 then FirstHVACIteration equals TRUE, if 0.0 then FirstHVACIteration equals false
      IF(FirstHVACIteration)Par(2)=1.0d0
      Par(3)  = REAL(UnitarySystem(UnitarySysNum)%FanOpMode,r64)
      Par(4)  = CompressorONFlag ! CompOp
      Par(5)  = ZoneLoad
      Par(6)  = 0.0d0 ! FLAG, 0.0 if heating load, 1.0 IF cooling or moisture load
      IF(CoolingLoad)Par(6)  = 1.0d0
      Par(7)  = 1.0d0 ! FLAG, 0.0 if latent load, 1.0 if sensible load to be met
      Par(8)  = OnOffAirFlowRatio ! Ratio of compressor ON mass flow rate to AVERAGE mass flow rate over time step
      Par(9)  = 0.0d0 ! HXUnitOn is always false for HX
      Par(10) = UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac
!     Tolerance is in fraction of load, MaxIter = 30, SolFalg = # of iterations or error as appropriate
      CALL SolveRegulaFalsi(0.001d0, MaxIter, SolFlag, PartLoadRatio, CalcUnitarySystemLoadResidual, 0.0d0, 1.0d0, Par)

      IF (SolFlag == -1) THEN
        IF(HeatingLoad)THEN
          ! IF iteration limit is exceeded, find tighter boundary of solution and repeat RegulaFalsi
          ! This does cause a problem when coil cannot turn on when OAT < min allowed or scheduled off
          ! If max iteration limit is exceeded, how do we know if the heating coil is operating?
          TempMaxPLR = -0.1d0
          TempSensOutput = SensOutputOff
          DO WHILE((TempSensOutput - ZoneLoad) .LT. 0.0d0 .AND. TempMaxPLR .LT. 1.0d0)
            ! find upper limit of HeatingPLR
            TempMaxPLR = TempMaxPLR + 0.1d0

            ! SUBROUTINE SetSpeedVariables(UnitarySysNum, SensibleLoad, PartLoadRatio)
            CALL SetSpeedVariables(UnitarySysNum, .TRUE., TempMaxPLR)
            CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,TempMaxPLR, &
                                         OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
          END DO
          TempMinPLR = TempMaxPLR
          DO WHILE((TempSensOutput - ZoneLoad) .GT. 0.0d0 .AND. TempMinPLR .GT. 0.0d0)
            ! pull upper limit of HeatingPLR down to last valid limit (i.e. heat output still exceeds SystemSensibleLoad)
            TempMaxPLR = TempMinPLR
            ! find minimum limit of HeatingPLR
            TempMinPLR = TempMinPLR - 0.01d0
            CALL SetSpeedVariables(UnitarySysNum, .TRUE., TempMinPLR)
            CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,TempMinPLR, &
                                         OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
          END DO
          ! Now solve again with tighter PLR limits
          CALL SolveRegulaFalsi(0.001d0, MaxIter, SolFlag, HeatPLR, CalcUnitarySystemLoadResidual, TempMinPLR, TempMaxPLR, Par)
          CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                                       OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
        ELSEIF(CoolingLoad)THEN
          ! RegulaFalsi may not find cooling PLR when the latent degradation model is used.
          ! IF iteration limit is exceeded, find tighter boundary of solution and repeat RegulaFalsi
          TempMaxPLR = -0.1d0
          TempSysOutput = SensOutputOff
          TempLoad = ZoneLoad
          DO WHILE((TempSysOutput - TempLoad) .GT. 0.0d0 .AND. TempMaxPLR .LT. 1.0d0)
            ! find upper limit of HeatingPLR
            TempMaxPLR = TempMaxPLR + 0.1d0
            CALL SetSpeedVariables(UnitarySysNum, .TRUE., TempMaxPLR)
            CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,TempMaxPLR,HeatPLR, &
                                       OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
            TempSysOutput = TempSensOutput
          END DO
          TempMinPLR = TempMaxPLR
          DO WHILE((TempSysOutput - TempLoad) .LT. 0.0d0 .AND. TempMinPLR .GT. 0.0d0)
            ! pull upper limit of HeatingPLR DOwn to last valid limit (i.e. heat output still exceeds SystemSensibleLoad)
            TempMaxPLR = TempMinPLR
            ! find minimum limit of HeatingPLR
            TempMinPLR = TempMinPLR - 0.01d0
            CALL SetSpeedVariables(UnitarySysNum, .TRUE., TempMinPLR)
            CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,TempMinPLR,HeatPLR, &
                                         OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
            TempSysOutput = TempSensOutput
          END DO
          ! Now solve again with tighter PLR limits
          CALL SolveRegulaFalsi(0.001d0, MaxIter, SolFlag, CoolPLR, CalcUnitarySystemLoadResidual, TempMinPLR, TempMaxPLR, Par)
          CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                                       OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
        END IF ! IF(HeatingLoad)THEN
        IF (SolFlag == -1) THEN
          IF(ABS(ZoneLoad - TempSensOutput) .GT. SmallLoad)THEN
            IF(UnitarySystem(UnitarySysNum)%MaxIterIndex == 0)THEN
              CALL ShowWarningMessage('Coil control failed to converge for ' &
               //TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//':'//TRIM(UnitarySystem(UnitarySysNum)%Name))
              CALL ShowContinueError('  Iteration limit exceeded in calculating system sensible part-load ratio.')
              CALL ShowContinueErrorTimeStamp('Sensible load to be met = ' &
               //TRIM(TrimSigDigits(ZoneLoad,2))//' (watts), sensible output = ' &
               //TRIM(TrimSigDigits(TempSensOutput,2))//' (watts), and the simulation continues.')
            END IF
            CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
             //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - Iteration limit exceeded in calculating'// &
             ' sensible part-load ratio error continues. Sensible load statistics:' &
             ,UnitarySystem(UnitarySysNum)%MaxIterIndex,ZoneLoad,ZoneLoad)
          END IF
        ELSEIF (SolFlag == -2) THEN
          IF(UnitarySystem(UnitarySysNum)%RegulaFalsIFailedIndex == 0)THEN
            CALL ShowWarningMessage('Coil control failed for ' &
             //TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//':'//TRIM(UnitarySystem(UnitarySysNum)%Name))
            CALL ShowContinueError('  sensible part-load ratio determined to be outside the range of 0-1.')
            CALL ShowContinueErrorTimeStamp('Sensible load to be met = ' &
            //TRIM(TrimSigDigits(ZoneLoad,2))//' (watts), and the simulation continues.')
          END IF
          CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
           //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - '// &
           ' sensible part-load ratio out of range error continues. Sensible load statistics:' &
           ,UnitarySystem(UnitarySysNum)%RegulaFalsIFailedIndex,ZoneLoad,ZoneLoad)
        END IF
      ELSEIF (SolFlag == -2) THEN
        IF(UnitarySystem(UnitarySysNum)%RegulaFalsIFailedIndex == 0)THEN
          CALL ShowWarningMessage('Coil control failed for ' &
            //TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//':'//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('  sensible part-load ratio determined to be outside the range of 0-1.')
          CALL ShowContinueErrorTimeStamp('Sensible load to be met = ' &
           //TRIM(TrimSigDigits(ZoneLoad,2))//' (watts), and the simulation continues.')
        END IF
        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
        //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - '// &
        ' sensible part-load ratio out of range error continues. Sensible load statistics:' &
        ,UnitarySystem(UnitarySysNum)%RegulaFalsIFailedIndex,ZoneLoad,ZoneLoad)
      END IF ! IF (SolFlag == -1) THEN
    ELSE ! load is not bounded by capacity. Leave PLR=1 or turn off unit?
      UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac = 0.0d0
      UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac = 0.0d0
      CoolPLR = 0.0d0
      HeatPLR = 0.0d0
      PartLoadRatio = 0.0d0
    END IF ! IF((HeatingLoad .AND. ZoneLoad > SensOutputOff) .OR. (CoolingLoad .AND. ZoneLoad < SensOutputOff))THEN
  END IF ! IF((HeatingLoad .AND. ZoneLoad < SensOutputOn) .OR. (CoolingLoad .AND. ZoneLoad > SensOutputOn))THEN

  IF(HeatingLoad .AND. (UnitarySystem(UnitarySysNum)%MultiSpeedHeatingCoil .OR. &
                        UnitarySystem(UnitarySysNum)%VarSpeedHeatingCoil)) THEN
    IF(UnitarySystem(UnitarySysNum)%HeatingSpeedNum == 1)THEN
      UnitarySystem(UnitarySysNum)%HeatingCycRatio   = PartLoadRatio
      UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 0.0d0
    ELSE
      UnitarySystem(UnitarySysNum)%HeatingCycRatio   = 1.0d0
      UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = PartLoadRatio
    END IF
    HeatPLR = PartLoadRatio
    CoolPLR = 0.0d0
    UnitarySystem(UnitarySysNum)%CoolingCycRatio   = 0.0d0
    UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
  ELSEIF(CoolingLoad .AND. (UnitarySystem(UnitarySysNum)%MultiSpeedCoolingCoil .OR. &
                            UnitarySystem(UnitarySysNum)%VarSpeedCoolingCoil))THEN
    IF(UnitarySystem(UnitarySysNum)%CoolingSpeedNum == 1)THEN
      UnitarySystem(UnitarySysNum)%CoolingCycRatio   = PartLoadRatio
      UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
    ELSE
      UnitarySystem(UnitarySysNum)%CoolingCycRatio   = 1.0d0
      UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = PartLoadRatio
    END IF
    UnitarySystem(UnitarySysNum)%HeatingCycRatio   = 0.0d0
    UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 0.0d0
    HeatPLR = 0.0d0
    CoolPLR = PartLoadRatio
  ELSE
    HeatPLR = UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac
    CoolPLR = UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac
  END IF

  CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                               OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)

! FullSensibleOutput is used to set supplemental heater PLR in calling routine
! OnOffAirFlowRatio is used to average air flow between ON and OFF state
  FullSensibleOutput = TempSensOutput

  ! RETURN of the moisture load is met
  IF(MoistureLoad >= 0.0d0 .OR. (MoistureLoad < 0.0d0 .AND. MoistureLoad >= TempLatOutput))RETURN
  ! Multimode does not meet the latent load, only the sensible load with or without HX active
  IF(.NOT. CoolingLoad .AND. UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_Multimode)RETURN
!  IF(HeatingLoad .AND. UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_CoolReheat)RETURN

  IF (( UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_CoolReheat .OR. &
          UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_Multimode))THEN

    ! find maximum latent output IF not already calculated
    IF(HeatingLoad)THEN
      CoolPLR = 1.0d0
      UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac = 1.0d0
      UnitarySystem(UnitarySysNum)%CoolingSpeedNum = UnitarySystem(UnitarySysNum)%NumOfSpeedCooling
      UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 1.0d0
      UnitarySystem(UnitarySysNum)%CoolingCycRatio   = 1.0d0
      UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac   = CoolPLR
      IF(UnitarySystem(UnitarySysNum)%CoolingSpeedNum .GT. 0)THEN
        UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac = 0.0d0
        UnitarySystem(UnitarySysNum)%HeatingSpeedNum = 0
        HeatPLR = 0.0d0
        CoolingLoad = .TRUE.
        HeatingLoad = .FALSE.
        UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand = 0.0d0
        UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand = MoistureLoad
        CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,0.0d0,0.0d0, &
                                   OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
        CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                                   OnOffAirFlowRatio,TempSensOutput,LatOutputOn,HXUnitOn,CompOn=CompressorONFlag)
      ELSE
        UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand = 0.0d0
        UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand = 0.0d0
        CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,0.0d0,0.0d0, &
                                   OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
        UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand = MoistureLoad
        CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                                   OnOffAirFlowRatio,TempSensOutput,LatOutputOn,HXUnitOn,CompOn=CompressorONFlag)
      END IF
    END IF

    IF(UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_Multimode .AND. &
       MoistureLoad < LatOutputOn)THEN
      HXUnitOn = .TRUE.
      CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                                   OnOffAirFlowRatio,TempSensOutput,LatOutputOn,HXUnitOn,CompOn=CompressorONFlag)
      FullSensibleOutput = TempSensOutput
    END IF

!    IF ((HeatingLoad .AND. MoistureLoad < TempLatOutput) .OR. &
!        (CoolingLoad .AND. MoistureLoad < TempLatOutput .AND. MoistureLoad > LatOutputOn) .OR. &
!        ((.NOT. HeatingLoad) .AND. (.NOT. CoolingLoad) .AND. MoistureLoad > LatOutputOn)) THEN
    IF ((MoistureLoad < TempLatOutput) .AND. (MoistureLoad > LatOutputOn)) THEN ! bounds check for RegulaFalsi

      ! save heating PLR
      HeatPLR = UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac
      Par(1)  = REAL(UnitarySysNum,r64)
      Par(2)  = 0.0d0  ! FLAG, if 1.0 then FirstHVACIteration equals TRUE, if 0.0 then FirstHVACIteration equals false
      IF(FirstHVACIteration)Par(2)=1.0d0
      Par(3)  = REAL(UnitarySystem(UnitarySysNum)%FanOpMode,r64)
      Par(4)  = CompressorONFlag ! CompOp
      IF(UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_Multimode)THEN
        Par(5)  = ZoneLoad
        Par(7)  = 1.0d0 ! FLAG, 0.0 if latent load, 1.0 if sensible load to be met
      ELSE
        Par(5)  = MoistureLoad
        Par(7)  = 0.0d0 ! FLAG, 0.0 if latent load, 1.0 if sensible load to be met
      END IF
      Par(6)  = 1.0d0 ! FLAG, 0.0 if heating load, 1.0 if cooling or moisture load
!      IF(HeatingLoad)Par(6)  = 0.0d0
      Par(8)  = OnOffAirFlowRatio ! Ratio of compressor ON mass flow rate to AVERAGE mass flow rate over time step
      IF (HXUnitOn) THEN
        Par(9) = 1.0d0
      ELSE
        Par(9) = 0.0d0
      END IF
      Par(10) = UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac
    ! Tolerance is fraction of load, MaxIter = 30, SolFalg = # of iterations or error as appropriate
      CALL SolveRegulaFalsi(0.001d0, MaxIter, SolFlagLat, PartLoadRatio, CalcUnitarySystemLoadResidual, 0.0d0, 1.0d0, Par)
!      IF (HeatingLoad) THEN
!        UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac = PartLoadRatio
!      ELSE
        UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac = PartLoadRatio
!      END IF
      UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac = HeatPLR
    ELSEIF(MoistureLoad < LatOutputOn .AND. CoolingLoad)THEN
!     Logic below needs further look...what to do if the bounds check for RegulaFalsi fail?
!     I'm not even sure if this should be done.
!     It's wrong anyway, since there won't be a cooling load if multimode (see RETURN about 80 lines up).
      IF(UnitarySystem(UnitarySysNum)%DehumidControlType_Num .NE. DehumidControl_Multimode) THEN
        UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac = 1.0d0
      END IF
    END IF
  END IF

  CoolPLR = UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac
  HeatPLR = UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac

  CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                               OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)

  IF (SolFlagLat == -1) THEN
    ! RegulaFalsi may not find cooling PLR when the latent degradation model is used.
    ! IF iteration limit is exceeded, find tighter boundary of solution and repeat RegulaFalsi
    TempMaxPLR = -0.1d0
    TempLatOutput = LatOutputOff
    DO WHILE((TempLatOutput - MoistureLoad) .GT. 0.0d0 .AND. TempMaxPLR .LT. 1.0d0)
      ! find upper limit of HeatingPLR
      TempMaxPLR = TempMaxPLR + 0.1d0
      CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,TempMaxPLR,HeatPLR, &
                                   OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
    END DO
    TempMinPLR = TempMaxPLR
    DO WHILE((TempLatOutput - MoistureLoad) .LT. 0.0 .AND. TempMinPLR .GT. 0.0d0)
      ! pull upper limit of HeatingPLR DOwn to last valid limit (i.e. heat output still exceeds SystemSensibleLoad)
      TempMaxPLR = TempMinPLR
      ! find minimum limit of HeatingPLR
      TempMinPLR = TempMinPLR - 0.01d0
      CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,TempMinPLR,HeatPLR, &
                                   OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
    END DO
    ! Now solve again with tighter PLR limits
    CALL SolveRegulaFalsi(0.001d0, MaxIter, SolFlagLat, CoolPLR, CalcUnitarySystemLoadResidual, TempMinPLR, TempMaxPLR, Par)
    CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                                 OnOffAirFlowRatio,TempSensOutput,TempLatOutput,HXUnitOn,CompOn=CompressorONFlag)
    IF (SolFlagLat == -1) THEN
      IF(ABS(MoistureLoad - TempLatOutput) .GT. SmallLoad)THEN
        IF(UnitarySystem(UnitarySysNum)%LatMaxIterIndex == 0)THEN
          CALL ShowWarningMessage('Coil control failed to converge for ' &
               //TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//':'//TRIM(UnitarySystem(UnitarySysNum)%Name))
          CALL ShowContinueError('  Iteration limit exceeded in calculating system Latent part-load ratio.')
          CALL ShowContinueErrorTimeStamp('Latent load to be met = ' &
             //TRIM(TrimSigDigits(MoistureLoad,2))//' (watts), Latent output = ' &
             //TRIM(TrimSigDigits(TempLatOutput,2))//' (watts), and the simulation continues.')
        END IF
        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
          //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - Iteration limit exceeded in calculating'// &
          ' Latent part-load ratio error continues. Latent load statistics:' &
          ,UnitarySystem(UnitarySysNum)%LatMaxIterIndex,MoistureLoad,MoistureLoad)
      END IF
    ELSEIF (SolFlagLat == -2) THEN
      IF(UnitarySystem(UnitarySysNum)%LatRegulaFalsIFailedIndex == 0)THEN
        CALL ShowWarningMessage('Coil control failed for ' &
              //TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//':'//TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('  Latent part-load ratio determined to be outside the range of 0-1.')
        CALL ShowContinueErrorTimeStamp('Latent load to be met = ' &
           //TRIM(TrimSigDigits(MoistureLoad,2))//' (watts), and the simulation continues.')
      END IF
      CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
        //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - '// &
        ' Latent part-load ratio out of range error continues. Latent load statistics:' &
        ,UnitarySystem(UnitarySysNum)%LatRegulaFalsIFailedIndex,MoistureLoad,MoistureLoad)
    END IF
  ELSEIF (SolFlagLat == -2) THEN
    IF(UnitarySystem(UnitarySysNum)%LatRegulaFalsIFailedIndex == 0)THEN
      CALL ShowWarningMessage('Coil control failed for ' &
              //TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//':'//TRIM(UnitarySystem(UnitarySysNum)%Name))
      CALL ShowContinueError('  Latent part-load ratio determined to be outside the range of 0-1.')
      CALL ShowContinueErrorTimeStamp('Latent load to be met = ' &
           //TRIM(TrimSigDigits(MoistureLoad,2))//' (watts), and the simulation continues.')
    END IF
    CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
        //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - '// &
        ' Latent part-load ratio out of range error continues. Latent load statistics:' &
        ,UnitarySystem(UnitarySysNum)%LatRegulaFalsIFailedIndex,MoistureLoad,MoistureLoad)
  END IF

  FullSensibleOutput = TempSensOutput

  CpAir = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%CoolCoilInletNodeNum)%HumRat, &
                         Node(UnitarySystem(UnitarySysNum)%CoolCoilInletNodeNum)%Temp)
  CoolingOnlySensibleOutput = Node(UnitarySystem(UnitarySysNum)%CoolCoilInletNodeNum)%MassFlowRate * CpAir * &
     ((Node(UnitarySystem(UnitarySysNum)%NodeNumOfControlledZone)%Temp-&
      Node(UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum)%Temp)- &
      (Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp-&
      Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%Temp))
  IF(QToHeatSetPt .LT. 0.0d0)THEN
!   Calculate the reheat coil load wrt the heating setpoint temperature. Reheat coil picks up
!   the entire excess sensible cooling (DX cooling coil and impact of outdoor air).
    UnitarySystem(UnitarySysNum)%DehumidInducedHeatingDemandRate = MAX(0.0d0,(CoolingOnlySensibleOutput+QToHeatSetPt))
!   Heating mode and dehumidification is required
  ELSEIF(QToHeatSetPt .GE. 0.0d0)THEN
!   Calculate the reheat coil load as the sensible capacity of the DX cooling coil only. Let
!   the heating coil pick up the load due to outdoor air.
    UnitarySystem(UnitarySysNum)%DehumidInducedHeatingDemandRate = MAX(0.0d0,CoolingOnlySensibleOutput)
  END IF

  RETURN

END SUBROUTINE ControlUnitarySystemOutput

SUBROUTINE SetSpeedVariables(UnitarySysNum, SensibleLoad, PartLoadRatio)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine determines operating PLR and calculates the load based system output.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE General,           ONLY: SolveRegulaFalsi, TrimSigDigits
  USE DataHeatBalFanSys, ONLY: TempControlType

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)              :: UnitarySysNum    ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL, INTENT(IN)              :: SensibleLoad     ! True when meeting a sensible load (not a moisture load)
  REAL(R64), INTENT(IN)            :: PartLoadRatio    ! operating PLR

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DEFINITIONS:
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  LOGICAL :: errflag         ! error flag returned from subroutine
  REAL(r64) :: RunTimeFrac   ! heat pump runtime fraction


  IF(HeatingLoad .AND. SensibleLoad)THEN
    UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
    UnitarySystem(UnitarySysNum)%CoolingCycRatio = 0.0d0
    IF(UnitarySystem(UnitarySysNum)%MultiSpeedHeatingCoil .OR. UnitarySystem(UnitarySysNum)%VarSpeedHeatingCoil) THEN
      IF(UnitarySystem(UnitarySysNum)%HeatingSpeedNum == 1)THEN
        UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 0.0d0
        UnitarySystem(UnitarySysNum)%HeatingCycRatio   = PartLoadRatio
      ELSE
        UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = PartLoadRatio
        UnitarySystem(UnitarySysNum)%HeatingCycRatio   = 1.0d0
      END IF
    ELSEIF(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple .OR. &
            UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHP)THEN
      CALL HeatPumpRunFrac(UnitarySysNum,PartLoadRatio,errflag,RuntimeFrac)
      IF(RuntimeFrac > 0.0d0 .AND. UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
        OnOffFanPartLoadFraction = PartLoadRatio/RuntimeFrac
      ELSE
        OnOffFanPartLoadFraction = 1
      END IF
      UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadRatio
      UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac   = RuntimeFrac
    END IF
  ELSE
    UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = 0.0d0
    UnitarySystem(UnitarySysNum)%HeatingCycRatio = 0.0d0
    IF(UnitarySystem(UnitarySysNum)%MultiSpeedCoolingCoil .OR. &
       UnitarySystem(UnitarySysNum)%VarSpeedCoolingCoil) THEN
      IF(UnitarySystem(UnitarySysNum)%CoolingSpeedNum == 1)THEN
        UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
        UnitarySystem(UnitarySysNum)%CoolingCycRatio   = PartLoadRatio
      ELSE
        UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = PartLoadRatio
        UnitarySystem(UnitarySysNum)%CoolingCycRatio   = 1.0d0
      END IF
    ELSEIF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHPSimple .OR. &
            UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHP)THEN
      CALL HeatPumpRunFrac(UnitarySysNum,PartLoadRatio,errflag,RuntimeFrac)
      IF(RuntimeFrac > 0.0d0 .AND. UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
        OnOffFanPartLoadFraction = PartLoadRatio/RuntimeFrac
      ELSE
        OnOffFanPartLoadFraction = 1.0d0
      END IF
      UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadRatio
      UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac   = RuntimeFrac
    ELSEIF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_CoolingTwoSpeed) THEN
      IF(UnitarySystem(UnitarySysNum)%CoolingSpeedNum == 1)THEN
        UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = 0.0d0
        UnitarySystem(UnitarySysNum)%CoolingCycRatio   = PartLoadRatio
      ELSE
        UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = PartLoadRatio
        UnitarySystem(UnitarySysNum)%CoolingCycRatio   = 1.0d0
      END IF
    END IF
  END IF


  RETURN

END SUBROUTINE SetSpeedVariables

FUNCTION CalcUnitarySystemLoadResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! To calculate the part-load ratio for the unitary system

          ! METHODOLOGY EMPLOYED:
          ! Use SolveRegulaFalsi to CALL this Function to converge on a solution

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
          ! na

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  REAL(r64), INTENT(IN)                         :: PartLoadRatio  ! DX cooling coil part load ratio
  REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par            ! Function parameters
  REAL(r64)                                     :: Residuum       ! Result (force to 0)

!   Parameter description example:
!       Par(1)  = REAL(UnitarySysNum,r64) ! Index to Unitary System
!       Par(2)  = 0.0                  ! FirstHVACIteration FLAG, IF 1.0 then TRUE, if 0.0 then FALSE
!       Par(3)  = REAL(OpMode,r64)     ! Fan control, IF 1.0 then cycling fan, if 0.0 then continuous fan
!       Par(4)  = REAL(CompOp,r64)     ! Compressor control, IF 1.0 then compressor ON, if 0.0 then compressor OFF
!       Par(5)  = SensLoad or MoistureLoad   ! Sensible or Latent load to be met by unitary system
!       Par(6)  = HeatingLoad or CoolingLoad ! Type of load FLAG, 0.0 IF heating load, 1.0 IF cooling or moisture load
!       Par(7)  = 1.0                  ! Output calculation FLAG, 0.0 for latent capacity, 1.0 for sensible capacity
!       Par(8)  = OnOffAirFlowRatio    ! Ratio of compressor ON air mass flow to AVERAGE air mass flow over time step
!       Par(9)  = HXUnitOn             ! flag to enable HX, 1=ON and 2=OFF
!       Par(10) = HeatingCoilPLR       ! used to calculate latent degradation for cycling fan RH control

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER    :: UnitarySysNum   ! Index to this unitary system
  LOGICAL    :: FirstHVACIteration ! FirstHVACIteration flag
  INTEGER    :: FanOpMode          ! Cycling fan or constant fan
  INTEGER    :: CompOp             ! Compressor on/off; 1=on, 0=off
  REAL(r64)  :: LoadToBeMet        ! Sensible or Latent load to be met
  REAL(r64)  :: OnOffAirFlowRatio  ! Ratio of compressor ON air mass flow to AVERAGE air mass flow over time step
  LOGICAL    :: HXUnitOn           ! flag to enable HX based on zone moisture load
  REAL(r64)  :: HeatPLR            ! heating coil part load ratio
  REAL(r64)  :: CoolPLR            ! cooling coil part load ratio
  LOGICAL    :: SensibleLoad       ! sensible load
  REAL(r64)  :: SensOutput         ! sensible output of system
  REAL(r64)  :: LatOutput          ! latent output of system

! Convert parameters to usable variables
  UnitarySysNum     = INT(Par(1))
  IF(Par(2) .EQ. 1.0d0)THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF
  FanOpMode            = INT(Par(3))
  CompOp               = INT(Par(4))
  LoadToBeMet          = Par(5)
  OnOffAirFlowRatio    = Par(8)

  IF(Par(6) .EQ. 1.0d0)THEN
   CoolPLR   = PartLoadRatio
   HeatPLR   = 0.0d0
  ELSE
   CoolPLR   = 0.0d0
   HeatPLR   = PartLoadRatio
  END IF

  SensibleLoad = .FALSE.
  IF(Par(7) .EQ. 1.0d0) SensibleLoad = .TRUE.

  IF(Par(9) .EQ. 1.0d0)THEN
    HXUnitOn = .TRUE.
  ELSE
    HXUnitOn = .FALSE.
  END IF

 CALL SetSpeedVariables(UnitarySysNum,SensibleLoad,PartLoadRatio)

 CALL CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
                    OnOffAirFlowRatio,SensOutput,LatOutput,HXUnitOn=HXUnitOn,CompOn=CompOp)

! Calculate residual based on output calculation flag
  IF(SensibleLoad) THEN
    IF(ABS(LoadToBeMet) .EQ. 0.0d0)THEN
      Residuum = (SensOutput - LoadToBeMet)/100.0d0
    ELSE
      Residuum = (SensOutput - LoadToBeMet)/LoadToBeMet
    END IF
  ELSE
    IF(ABS(LoadToBeMet) .EQ. 0.0d0)THEN
      Residuum = (LatOutput - LoadToBeMet)/100.0d0
    ELSE
      Residuum = (LatOutput - LoadToBeMet)/LoadToBeMet
    END IF
  END IF

RETURN
END FUNCTION CalcUnitarySystemLoadResidual

SUBROUTINE CalcUnitarySystemToLoad(UnitarySysNum,FirstHVACIteration,CoolPLR,HeatPLR, &
             OnOffAirFlowRatio,SensOutput,LatOutput,HXUnitOn,HeatCoilLoad,SuppCoilLoad,CompOn)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine calculates the resulting performance of the unitary system given
          ! the operating PLR. System output is calculated with respect to zone condition.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE Fans,             ONLY: SimulateFanComponents
  USE Psychrometrics,   ONLY: PsyHFnTdbW, PsyCpAirFnWTdb

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER,   INTENT(IN)        :: UnitarySysNum    ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL,   INTENT(IN)        :: FirstHVACIteration  ! True when first HVAC iteration
  REAL(R64), INTENT(IN)        :: CoolPLR             ! operating cooling part-load ratio []
  REAL(R64), INTENT(IN)        :: HeatPLR             ! operating cooling part-load ratio []
  REAL(R64), INTENT(INOUT)     :: OnOffAirFlowRatio   ! ratio of heating PLR to cooling PLR (is this correct?)
  REAL(R64), INTENT(INOUT)     :: SensOutput          ! sensible capacity (W)
  REAL(R64), INTENT(INOUT)     :: LatOutput           ! latent capacity (W)
  LOGICAL, INTENT(INOUT), OPTIONAL :: HXUnitOn        ! Flag to control HX for HXAssisted Cooling Coil
  REAL(r64), INTENT(INOUT), OPTIONAL :: HeatCoilLoad  ! Adjusted load to heating coil when SAT exceeds max limit (W)
  REAL(r64), INTENT(INOUT), OPTIONAL :: SuppCoilLoad  ! Adjusted load to supp heating coil when SAT exceeds max limit (W)
  INTEGER, OPTIONAL, INTENT(IN)   :: CompOn           ! Determines if compressor is on or off

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER                       :: OutletNode         ! DX System outlet node number
  REAL(R64)                     :: SuppPLR            ! supplemental heating coil operating part-load ratio
  REAL(R64)                     :: MinHumRatio        ! used to calculate delivered capacity
  REAL(R64)                     :: AirMassFlow        ! operating mass flow rate through unitary system (kg/s)
  REAL(R64)                     :: ZoneTemp           ! zone node temperature (C)
  REAL(R64)                     :: ZoneHumRat         ! zone node humidity ratio (kg-water/kg-dryair)
  REAL(R64)                     :: CoilCoolHeatRat    ! ratio of cooling to heating PLR for cycling fan RH control
  INTEGER                       :: CoolingCompOn      ! Compressor control (0=off, 1=on1)
  INTEGER                       :: HeatingCompOn      ! Compressor control (0=off, 1=on1)
  REAL(r64)                     :: MDotAir            ! inlet air mass flow rate [kg/s]
  REAL(r64)                     :: CpAir              ! average specific heat [J/kg-C]
  REAL(r64)                     :: CpAirIn            ! inlet air Cp  [J/kg-C]
  REAL(r64)                     :: CpAirOut           ! outlet air Cp [J/kg-C]
  REAL(r64)                     :: HCDeltaT           ! heating coil delta temperture [deltaC]
  REAL(r64)                     :: MaxHeatCoilLoad    ! maximum allowed coil load so max temp is not exceeded [W]

  CoolingCompOn=0
  IF(CoolPLR>0)THEN
    CoolingCompOn=1
    ! let logical override compressor status if present (tests if economizer can meet load without compressor)
    IF(PRESENT(CompOn))CoolingCompOn=CompOn
  ! for multispeed coils, comp is on IF speed > 1
  ELSEIF(UnitarySystem(UnitarySysNum)%CoolingSpeedNum .GT. 1)THEN
    CoolingCompOn=1
  END IF

  HeatingCompOn=0
  IF(HeatPLR>0)THEN
    HeatingCompOn=1
    ! let logical override compressor status if present (tests if economizer can meet load without compressor)
    ! probably don't need this for heating mode
    IF(PRESENT(CompOn))HeatingCompOn=CompOn
    CoilCoolHeatRat = MIN(1.0d0,CoolPLR/HeatPLR)
  ELSE
    CoilCoolHeatRat = 1.0d0
  END IF
  ! for multispeed coils, comp is on at PLR=0 IF speed > 1
  IF(UnitarySystem(UnitarySysNum)%HeatingSpeedNum .GT. 1)HeatingCompOn=1

  ! set the operating flow rate
  IF(UnitarySystem(UnitarySysNum)%NumOfSpeedCooling > 0 .OR. &
     UnitarySystem(UnitarySysNum)%NumOfSpeedHeating > 0)THEN
     CALL SetOnOffMassFlowRate(UnitarySysNum, OnOffAirFlowRatio, MAX(CoolPLR,HeatPLR))
  ELSE
    CALL SetAverageAirFlow(UnitarySysNum, MAX(CoolPLR,HeatPLR), OnOffAirFlowRatio)
  END IF

  ! Call the series of components that simulate a Unitary System
  IF (UnitarySystem(UnitarySysNum)%FanExists .AND. UnitarySystem(UnitarySysNum)%FanPlace .EQ. BlowThru) THEN
    CALL SimulateFanComponents(Blank,FirstHVACIteration,UnitarySystem(UnitarySysNum)%FanIndex,FanSpeedRatio)
  END IF

  IF(UnitarySystem(UnitarySysNum)%CoolingCoilUpstream)THEN

    IF (UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
      CALL CalcUnitaryCoolingSystem(UnitarySysNum, FirstHVACIteration, CoolPLR, CoolingCompOn, OnOffAirFlowRatio, &
                                    CoilCoolHeatRat, HXUnitOn)
    END IF
    IF (UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
      ! operate the heating coil without regard to coil outlet temperature
      CALL CalcUnitaryHeatingSystem(UnitarySysNum, FirstHVACIteration, HeatPLR, HeatingCompOn, &
                                    OnOffAirFlowRatio, HeatCoilLoad)
      IF(Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp .GT. &
           UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp)THEN
        MDotAir = Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%MassFlowRate
        CpAirIn  = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%HumRat, &
                                  Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%Temp)
        CpAirOut = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%HumRat, &
                                  Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp)
        CpAir = (CpAirIn + CpAirout)/2
        HCDeltaT = UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp - &
                   Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%Temp
        MaxHeatCoilLoad = MDotAir * CpAir * HCDeltaT
        CALL CalcUnitaryHeatingSystem(UnitarySysNum, FirstHVACIteration, HeatPLR, HeatingCompOn, &
                                      OnOffAirFlowRatio, MaxHeatCoilLoad)
        IF(PRESENT(HeatCoilLoad))HeatCoilLoad = MaxHeatCoilLoad
      END IF
    END IF

    ! If blow thru fan is used, the fan must be simulated after coil sets OnOffFanPartLoadFraction
    IF (UnitarySystem(UnitarySysNum)%FanExists .AND. UnitarySystem(UnitarySysNum)%FanPlace .EQ. BlowThru .AND. &
        OnOffFanPartLoadFraction < 1.0d0) THEN
      CALL SimulateFanComponents(Blank,FirstHVACIteration,UnitarySystem(UnitarySysNum)%FanIndex,FanSpeedRatio)

      IF (UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
        CALL CalcUnitaryCoolingSystem(UnitarySysNum, FirstHVACIteration, CoolPLR, CoolingCompOn, OnOffAirFlowRatio, &
                                    CoilCoolHeatRat, HXUnitOn)
      END IF
      IF (UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
        CALL CalcUnitaryHeatingSystem(UnitarySysNum, FirstHVACIteration, HeatPLR, HeatingCompOn, OnOffAirFlowRatio, HeatCoilLoad)
        IF(Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp .GT. &
           UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp)THEN
          MDotAir = Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%MassFlowRate
          CpAirIn  = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%HumRat, &
                                    Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%Temp)
          CpAirOut = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%HumRat, &
                                    Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp)
          CpAir = (CpAirIn + CpAirout)/2
          HCDeltaT = UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp - &
                     Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%Temp
          MaxHeatCoilLoad = MDotAir * CpAir * HCDeltaT
          CALL CalcUnitaryHeatingSystem(UnitarySysNum, FirstHVACIteration, HeatPLR, HeatingCompOn, &
                                        OnOffAirFlowRatio, MaxHeatCoilLoad)
        END IF
      END IF
    END IF

  ELSE

    IF (UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
      CALL CalcUnitaryHeatingSystem(UnitarySysNum, FirstHVACIteration, HeatPLR, HeatingCompOn, OnOffAirFlowRatio, HeatCoilLoad)
      IF(Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp .GT. &
           UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp)THEN
        MDotAir = Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%MassFlowRate
        CpAirIn  = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%HumRat, &
                                  Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%Temp)
        CpAirOut = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%HumRat, &
                                  Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp)
        CpAir = (CpAirIn + CpAirout)/2
        HCDeltaT = UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp - &
                   Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%Temp
        MaxHeatCoilLoad = MDotAir * CpAir * HCDeltaT
        CALL CalcUnitaryHeatingSystem(UnitarySysNum, FirstHVACIteration, HeatPLR, HeatingCompOn, &
                                      OnOffAirFlowRatio, MaxHeatCoilLoad)
      END IF
    END IF
    IF (UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
      CALL CalcUnitaryCoolingSystem(UnitarySysNum, FirstHVACIteration, CoolPLR, CoolingCompOn, OnOffAirFlowRatio, &
                                    CoilCoolHeatRat, HXUnitOn)
    END IF

    ! If blow thru fan is used, the fan must be simulated after coil sets OnOffFanPartLoadFraction
    IF (UnitarySystem(UnitarySysNum)%FanExists .AND. UnitarySystem(UnitarySysNum)%FanPlace .EQ. BlowThru .AND. &
        OnOffFanPartLoadFraction < 1.0d0) THEN
      CALL SimulateFanComponents(Blank,FirstHVACIteration,UnitarySystem(UnitarySysNum)%FanIndex,FanSpeedRatio)

      IF (UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
        CALL CalcUnitaryHeatingSystem(UnitarySysNum, FirstHVACIteration, HeatPLR, HeatingCompOn, OnOffAirFlowRatio, HeatCoilLoad)
        IF(Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp .GT. &
           UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp)THEN
          MDotAir = Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%MassFlowRate
          CpAirIn  = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%HumRat, &
                                    Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%Temp)
          CpAirOut = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%HumRat, &
                                    Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp)
          CpAir = (CpAirIn + CpAirout)/2
          HCDeltaT = UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp - &
                     Node(UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum)%Temp
          MaxHeatCoilLoad = MDotAir * CpAir * HCDeltaT
          CALL CalcUnitaryHeatingSystem(UnitarySysNum, FirstHVACIteration, HeatPLR, HeatingCompOn, &
                                        OnOffAirFlowRatio, MaxHeatCoilLoad)
        END IF
      END IF
      IF (UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
        CALL CalcUnitaryCoolingSystem(UnitarySysNum, FirstHVACIteration, CoolPLR, CoolingCompOn, OnOffAirFlowRatio, &
                                    CoilCoolHeatRat, HXUnitOn)
      END IF
    END IF

  END IF

  IF (UnitarySystem(UnitarySysNum)%FanExists .AND. UnitarySystem(UnitarySysNum)%FanPlace .EQ. DrawThru) THEN
    CALL SimulateFanComponents(Blank,FirstHVACIteration,UnitarySystem(UnitarySysNum)%FanIndex,FanSpeedRatio)
  END IF

  SuppPLR = UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac
  IF (UnitarySystem(UnitarySysNum)%SuppCoilExists)THEN
    CALL CalcUnitarySuppHeatingSystem(UnitarySysNum, FirstHVACIteration, SuppPLR, SuppCoilLoad)
    IF((Node(UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode)%Temp .GT. &
        UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp) .AND. SuppPLR .GT. 0.0d0)THEN
      MDotAir = Node(UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode)%MassFlowRate
      CpAirIn  = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode)%HumRat, &
                                Node(UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode)%Temp)
      CpAirOut = PsyCpAirFnWTdb(Node(UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode)%HumRat, &
                                Node(UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode)%Temp)
      CpAir = (CpAirIn + CpAirout)/2
      HCDeltaT = MAX(0.0d0,UnitarySystem(UnitarySysNum)%DesignMaxOutletTemp - &
                           Node(UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode)%Temp)
      MaxHeatCoilLoad = MDotAir * CpAir * HCDeltaT
      CALL CalcUnitarySuppHeatingSystem(UnitarySysNum, FirstHVACIteration, SuppPLR, MaxHeatCoilLoad)
      IF(PRESENT(SuppCoilLoad))SuppCoilLoad = MaxHeatCoilLoad
    END IF
  END IF

 ! Check delta T (outlet to space), IF positive
 ! use space HumRat (next line), ELSE outlet humrat (IF) so psyc routine gives good result
  MinHumRatio = Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%HumRat
  OutletNode = UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum
  AirMassFlow = Node(OutletNode)%MassFlowRate
  ZoneTemp = Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%Temp
  ZoneHumRat = Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%HumRat
  IF(Node(OutletNode)%Temp .LT. ZoneTemp ) MinHumRatio = Node(OutletNode)%HumRat

 ! Calculate sensible load met (at constant humidity ratio)
  SensOutput = AirMassFlow * (PsyHFnTdbW(Node(OutletNode)%Temp,MinHumRatio)  &
         - PsyHFnTdbW(ZoneTemp,MinHumRatio)) &
         - UnitarySystem(UnitarySysNum)%SenLoadLoss
  UnitarySystem(UnitarySysNum)%SensibleLoadMet = SensOutput

  IF(UnitarySystem(UnitarySysNum)%Humidistat)THEN

!   Calculate latent load met (at constant temperature)
    LatOutput = AirMassFlow * (PsyHFnTdbW(ZoneTemp,Node(OutletNode)%HumRat)  &
         - PsyHFnTdbW(ZoneTemp,ZoneHumRat)) - UnitarySystem(UnitarySysNum)%LatLoadLoss
  ELSE
    LatOutput = 0.0d0
  END IF
  UnitarySystem(UnitarySysNum)%LatentLoadMet = LatOutput

  RETURN

END SUBROUTINE CalcUnitarySystemToLoad

SUBROUTINE CalcUnitaryCoolingSystem(UnitarySysNum, FirstHVACIteration, PartLoadRatio, &
                                    CompOn, OnOffAirFlowRatio, CoilCoolHeatRat, HXUnitOn)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine manages unitary cooling system component simulation.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DXCoils,                   ONLY: SimDXCoil, SimDXCoilMultiSpeed, SimDXCoilMultiMode
  USE HVACHXAssistedCoolingCoil, ONLY: SimHXAssistedCoolingCoil
  USE Fans,                      ONLY: SimulateFanComponents
  USE WaterCoils,                ONLY: SimulateWaterCoilComponents
  USE VariableSpeedCoils,        ONLY: SimVariableSpeedCoils
  USE WatertoAirHeatPumpSimple,  ONLY: SimWatertoAirHPSimple
  USE WatertoAirHeatPump,        ONLY: SimWaterToAirHP

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)          :: UnitarySysNum       ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL, INTENT(IN)          :: FirstHVACIteration  ! True when first HVAC iteration
  REAL(R64), INTENT(IN)        :: PartLoadRatio       ! coil operating part-load ratio
  INTEGER, INTENT(IN)          :: CompOn              ! compressor control (0=off, 1=on)
  REAL(R64), INTENT(IN)        :: OnOffAirFlowRatio   !
  REAL(R64), INTENT(IN)        :: CoilCoolHeatRat     ! ratio of cooling to heating PLR for cycling fan RH control
  LOGICAL, INTENT(INOUT), OPTIONAL :: HXUnitOn        ! Flag to control HX for HXAssisted Cooling Coil

          ! SUBROUTINE PARAMETER DEFINITIONS:

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName            ! Name of Unitary System object
  INTEGER                       :: CompIndex           ! index to cooling coil
  REAL(R64)                     :: OutsideDryBulbTemp  ! outdoor temperature (C)
  REAL(r64)                     :: mdot                ! water side flow rate (kg/s)
  REAL(r64)                     :: QActual             ! actual coil output (W)
  REAL(r64)                     :: OutdoorPressure     ! Outdoor barometric pressure at condenser (Pa)
  LOGICAL                       :: errflag             ! returned flag from called routine

! Simulate the coil component
  CompName = UnitarySystem(UnitarySysNum)%CoolingCoilName
  CompIndex = UnitarySystem(UnitarySysNum)%CoolingCoilIndex
  IF (UnitarySystem(UnitarySysNum)%CondenserNodeNum /= 0) THEN
    OutdoorPressure = Node(UnitarySystem(UnitarySysNum)%CondenserNodeNum)%Press
    ! IF node is not connected to anything, pressure = default, use weather data
    IF(OutdoorPressure == DefaultNodeValues%Press)THEN
      OutsideDryBulbTemp  = OutDryBulbTemp
!      OutdoorHumRat   = OutHumRat
!      OutdoorPressure = OutBaroPress
!      OutdoorWetBulb  = OutWetBulbTemp
    ELSE
      OutsideDryBulbTemp  = Node(UnitarySystem(UnitarySysNum)%CondenserNodeNum)%Temp
!      OutdoorHumRat   = Node(UnitarySystem(UnitarySysNum)%CondenserNodeNum)%HumRat
!      OutdoorWetBulb  = PsyTwbFnTdbWPb(OutdoorDryBulb,OutdoorHumRat,OutdoorPressure,RoutineName)
    END IF
  ELSE
    OutsideDryBulbTemp  = OutDryBulbTemp
!    OutdoorHumRat   = OutHumRat
!    OutdoorPressure = OutBaroPress
!    OutdoorWetBulb  = OutWetBulbTemp
  END IF
!  PartLoadRatio = UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac

  SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

    CASE (CoilDX_CoolingSingleSpeed) ! Coil:Cooling:DX:SingleSpeed

      CALL SimDXCoil(Blank,CompOn,FirstHVACIteration, PartLoadRatio,  &
         CompIndex, &
         UnitarySystem(UnitarySysNum)%FanOpMode, &
         CoilCoolingHeatingPLRRatio = CoilCoolHeatRat)
      UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio = PartLoadRatio*REAL(CompOn,r64)

    CASE (CoilDX_CoolingHXAssisted,CoilWater_CoolingHXAssisted)  ! CoilSystem:Cooling:*:HeatExchangerAssisted

      IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num==CoilWater_CoolingHXAssisted)THEN
        mdot = MIN(Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
                 UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow * PartLoadRatio)
        Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode)%MassFlowRate = mdot
      END IF
      CALL SimHXAssistedCoolingCoil(Blank,FirstHVACIteration,CompOn,PartLoadRatio,  &
                                CompIndex, UnitarySystem(UnitarySysNum)%FanOpMode, &
                                HXUnitEnable=HXUnitOn,EconomizerFlag=EconomizerFlag)
      IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num==CoilDX_CoolingHXAssisted) &
           UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio = PartLoadRatio*REAL(CompOn,r64)

    CASE (CoilDX_CoolingTwoSpeed)  ! Coil:Cooling:DX:TwoSpeed
                                   ! formerly (v3 and beyond)COIL:DX:MULTISPEED:COOLINGEMPIRICAL

      CALL SimDXCoilMultiSpeed(Blank,UnitarySystem(UnitarySysNum)%CoolingSpeedRatio,&
                     UnitarySystem(UnitarySysNum)%CoolingCycRatio,CompIndex)
      IF(UnitarySystem(UnitarySysNum)%CoolingSpeedRatio .GT. 0.0d0)THEN
        UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio = UnitarySystem(UnitarySysNum)%CoolingSpeedRatio*REAL(CompOn,r64)
      ELSE
        UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio = UnitarySystem(UnitarySysNum)%CoolingCycRatio*REAL(CompOn,r64)
      END IF

    CASE (CoilDX_MultiSpeedCooling) ! Coil:Cooling:DX:Multispeed

      IF(OutsideDryBulbTemp .GT. UnitarySystem(UnitarySysNum)%MinOATCompressor) THEN
        CALL SimDXCoilMultiSpeed(CompName,UnitarySystem(UnitarySysNum)%CoolingSpeedRatio, &
                                 UnitarySystem(UnitarySysNum)%CoolingCycRatio,&
                                 CompIndex, &
                                 UnitarySystem(UnitarySysNum)%CoolingSpeedNum, &
                                 UnitarySystem(UnitarySysNum)%FanOpMode,CompOn)
        IF(UnitarySystem(UnitarySysNum)%CoolingSpeedNum .GT. 1)THEN
          UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio = REAL(CompOn,r64)
        ELSE
          UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio = UnitarySystem(UnitarySysNum)%CoolingCycRatio*REAL(CompOn,r64)
        END IF
      ELSE
        CALL SimDXCoilMultiSpeed(CompName,0.0d0,0.0d0,&
                                 CompIndex, &
                                 UnitarySystem(UnitarySysNum)%CoolingSpeedNum, &
                                 UnitarySystem(UnitarySysNum)%FanOpMode,CompOn)
        UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio = 0.0d0
      END IF

    CASE (CoilDX_CoolingTwoStageWHumControl)  ! Coil:Cooling:DX:TwoStageWithHumidityControlMode
                                     ! formerly (v3 and beyond) COIL:DX:MULTIMODE:COOLINGEMPIRICAL

      CALL SimDXCoilMultiMode(CompName,CompOn,FirstHVACIteration,PartLoadRatio, &
                     UnitarySystem(UnitarySysNum)%dehumidificationMode, &
                     CompIndex, &
                     UnitarySystem(UnitarySysNum)%FanOpMode)
      UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio = PartLoadRatio*REAL(CompOn,r64)

    CASE (Coil_CoolingWater, Coil_CoolingWaterDetailed)
      mdot = MIN(Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
                 UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow * PartLoadRatio)
      Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode)%MassFlowRate = mdot
      CALL SimulateWaterCoilComponents(CompName,FirstHVACIteration, &
                                           UnitarySystem(UnitarySysNum)%CoolingCoilIndex,  &
                                           QActual,UnitarySystem(UnitarySysNum)%FanOpMode, &
                                           PartLoadRatio)

    CASE (Coil_CoolingAirToAirVariableSpeed, Coil_CoolingWaterToAirHPVSEquationFit)
      CALL SimVariableSpeedCoils(CompName,CompIndex,&
           UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
           UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime,&
           CompOn, PartLoadRatio, OnOffAirFlowRatio, &
           UnitarySystem(UnitarySysNum)%CoolingSpeedNum, &
           UnitarySystem(UnitarySysNum)%CoolingSpeedRatio,&
           UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand, &
           UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand )


    CASE(Coil_CoolingWaterToAirHPSimple)

        IF(PartLoadRatio > 0.0d0 .AND. UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac > 0.0d0 .AND. &
           UnitarySystem(UnitarySysNum)%FanOpMode == CycFanCycCoil)THEN
          OnOffFanPartLoadFraction = PartLoadRatio/UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac
        END IF

        CALL SimWatertoAirHPSimple(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                   UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand, &
                                   UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand, &
                                   UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac, &
                                   UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                   UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                   CompOn, PartLoadRatio, FirstHVACIteration)

        UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio = PartLoadRatio*REAL(CompOn,r64)

    CASE(Coil_CoolingWaterToAirHP)

        CALL HeatPumpRunFrac(UnitarySysNum,PartLoadRatio,errflag,UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac)

        IF(PartLoadRatio > 0.0d0 .AND. UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac > 0.0d0 .AND. &
           UnitarySystem(UnitarySysNum)%FanOpMode == CycFanCycCoil)THEN
          OnOffFanPartLoadFraction = PartLoadRatio/UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac
        END IF

        CALL SimWatertoAirHP(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
              UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow,UnitarySystem(UnitarySysNum)%FanOpMode,&
              FirstHVACIteration,UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac,&
              UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
              UnitarySystem(UnitarySysNum)%HPTimeConstant, &
              UnitarySystem(UnitarySysNum)%FanDelayTime, &
              UnitarySystem(UnitarySysNum)%InitHeatPump, &
              UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand, &
              UnitarySystem(UnitarySysNum)%CoolingCoilLatentDemand,CompOn, PartLoadRatio)

        UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio = PartLoadRatio*REAL(CompOn,r64)

  END SELECT

  UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac = PartLoadRatio

  RETURN

END SUBROUTINE CalcUnitaryCoolingSystem

SUBROUTINE CalcUnitaryHeatingSystem(UnitarySysNum, FirstHVACIteration, PartLoadRatio, CompOn, OnOffAirFlowRatio, HeatCoilLoad)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine manages unitary heating system component simulation.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DXCoils,                   ONLY: SimDXCoil, SimDXCoilMultiSpeed
  USE HeatingCoils,              ONLY: SimulateHeatingCoilComponents
  USE WaterCoils,                ONLY: SimulateWaterCoilComponents
  USE SteamCoils,                ONLY: SimulateSteamCoilComponents
  USE VariableSpeedCoils,        ONLY: SimVariableSpeedCoils
  USE WatertoAirHeatPumpSimple,  ONLY: SimWatertoAirHPSimple
  USE WatertoAirHeatPump,        ONLY: SimWaterToAirHP

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)          :: UnitarySysNum    ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL, INTENT(IN)          :: FirstHVACIteration  ! True when first HVAC iteration
  REAL(R64), INTENT(IN)        :: PartLoadRatio       ! coil operating part-load ratio
  INTEGER, INTENT(IN)          :: CompOn              ! comrpressor control (0=off, 1=on)
  REAL(R64), INTENT(IN)        :: OnOffAirFlowRatio   ! ratio of on to off flow rate
  REAL(r64), OPTIONAL, INTENT(IN) :: HeatCoilLoad     ! adjusted heating coil load if outlet temp exceeds max (W)

          ! SUBROUTINE PARAMETER DEFINITIONS:

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName            ! Name of Unitary System object
  REAL(R64)                     :: OutsideDryBulbTemp  ! outdoor temperature (C)
  REAL(r64)                     :: mdot                ! water side flow rate (kg/s)
  REAL(r64)                     :: QActual             ! actual output of coil (W)
  REAL(r64)                     :: dummy               ! used when sub argument is not needed
  REAL(r64)                     :: OutdoorPressure     ! Outdoor barometric pressure at condenser (Pa)
  LOGICAL                       :: errflag             ! returned flag from called routine

  CompName = UnitarySystem(UnitarySysNum)%HeatingCoilName
  dummy = 0.0d0
  IF (UnitarySystem(UnitarySysNum)%CondenserNodeNum /= 0) THEN
    OutdoorPressure = Node(UnitarySystem(UnitarySysNum)%CondenserNodeNum)%Press
    ! IF node is not connected to anything, pressure = default, use weather data
    IF(OutdoorPressure == DefaultNodeValues%Press)THEN
      OutsideDryBulbTemp  = OutDryBulbTemp
!      OutdoorHumRat   = OutHumRat
!      OutdoorPressure = OutBaroPress
!      OutdoorWetBulb  = OutWetBulbTemp
    ELSE
      OutsideDryBulbTemp  = Node(UnitarySystem(UnitarySysNum)%CondenserNodeNum)%Temp
!      OutdoorHumRat   = Node(UnitarySystem(UnitarySysNum)%CondenserNodeNum)%HumRat
!      OutdoorWetBulb  = PsyTwbFnTdbWPb(OutdoorDryBulb,OutdoorHumRat,OutdoorPressure,RoutineName)
    END IF
  ELSE
    OutsideDryBulbTemp  = OutDryBulbTemp
!    OutdoorHumRat   = OutHumRat
!    OutdoorPressure = OutBaroPress
!    OutdoorWetBulb  = OutWetBulbTemp
  END IF

  SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)

    CASE (CoilDX_HeatingEmpirical) ! COIL:HEATING:DX:SINGLESPEED

        CALL SimDXCoil(CompName,CompOn,FirstHVACIteration, PartLoadRatio,  &
                       UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                       UnitarySystem(UnitarySysNum)%FanOpMode)
        UnitarySystem(UnitarySysNum)%HeatCompPartLoadRatio = PartLoadRatio*REAL(CompOn,r64)

    CASE (Coil_HeatingGas,Coil_HeatingElectric )
      IF(PRESENT(HeatCoilLoad))THEN
          CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                SuppHeat=.FALSE., &
                                QCoilReq=HeatCoilLoad, &
                                FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                PartLoadRatio=PartLoadRatio)
      ELSE
          CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                SuppHeat=.FALSE., &
                                QCoilReq=UnitarySystem(UnitarySysNum)%DesignHeatingCapacity*PartLoadRatio, &
                                FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                PartLoadRatio=PartLoadRatio)
      END IF
    CASE (Coil_HeatingDesuperheater )
      IF(PRESENT(HeatCoilLoad))THEN
          CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                SuppHeat=.FALSE., &
                                QCoilReq=HeatCoilLoad, &
                                FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                PartLoadRatio=PartLoadRatio)
      ELSE
          CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                SuppHeat=.FALSE., &
                                QCoilReq=UnitarySystem(UnitarySysNum)%DesignHeatingCapacity*PartLoadRatio, &
                                FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                PartLoadRatio=PartLoadRatio)
      END IF

    CASE(CoilDX_MultiSpeedHeating)

        IF(OutsideDryBulbTemp .GT. UnitarySystem(UnitarySysNum)%MinOATCompressor)THEN
          CALL SimDXCoilMultiSpeed(CompName,UnitarySystem(UnitarySysNum)%HeatingSpeedRatio, &
                                   UnitarySystem(UnitarySysNum)%HeatingCycRatio,&
                                   UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                   UnitarySystem(UnitarySysNum)%HeatingSpeedNum, &
                                   UnitarySystem(UnitarySysNum)%FanOpMode,CompOn)
          UnitarySystem(UnitarySysNum)%HeatCompPartLoadRatio = PartLoadRatio*REAL(CompOn,r64)
        ELSE
          CALL SimDXCoilMultiSpeed(CompName,0.0d0,0.0d0,&
                                   UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                   UnitarySystem(UnitarySysNum)%HeatingSpeedNum, &
                                   UnitarySystem(UnitarySysNum)%FanOpMode,CompOn)
          UnitarySystem(UnitarySysNum)%HeatCompPartLoadRatio = 0.0d0
        END IF

    CASE(Coil_HeatingElectric_MultiStage, Coil_HeatingGas_MultiStage)
        CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                           CompIndex     = 0, &
                                           FanOpMode     = UnitarySystem(UnitarySysNum)%FanOpMode,      &
                                           PartLoadRatio = UnitarySystem(UnitarySysNum)%HeatingCycRatio, &
                                           StageNum      = UnitarySystem(UnitarySysNum)%HeatingSpeedNum,     &
                                           SpeedRatio    = UnitarySystem(UnitarySysNum)%HeatingSpeedRatio)

    CASE (Coil_HeatingWater)
          mdot = MIN(Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
                 UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow * PartLoadRatio)
          Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode)%MassFlowRate = mdot
          CALL SimulateWaterCoilComponents(CompName,FirstHVACIteration, &
                                           UnitarySystem(UnitarySysNum)%HeatingCoilIndex,  &
                                           QActual,UnitarySystem(UnitarySysNum)%FanOpMode, &
                                           PartLoadRatio)

    CASE (Coil_HeatingSteam)
! this same CALL is made in the steam coil calc routine
          mdot = MIN(Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
                 UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow * PartLoadRatio)
          Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode)%MassFlowRate = mdot
          CALL SimulateSteamCoilComponents(CompName, FirstHVACIteration, &
                                           UnitarySystem(UnitarySysNum)%DesignHeatingCapacity*PartLoadRatio, &
                                           UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                           FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode, &
                                           PartLoadRatio = PartLoadRatio)

    CASE(Coil_HeatingAirToAirVariableSpeed, Coil_HeatingWaterToAirHPVSEquationFit)

        CALL SimVariableSpeedCoils(CompName,UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
             UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
             UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime, &
             CompOn, PartLoadRatio, OnOffAirFlowRatio, &
             UnitarySystem(UnitarySysNum)%HeatingSpeedNum, UnitarySystem(UnitarySysNum)%HeatingSpeedRatio, &
             UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand, dummy)
        IF(UnitarySystem(UnitarySysNum)%HeatingSpeedNum .GT. 1.0d0)THEN
          UnitarySystem(UnitarySysNum)%HeatCompPartLoadRatio = 1.0d0
        ELSE
          UnitarySystem(UnitarySysNum)%HeatCompPartLoadRatio = PartLoadRatio*REAL(CompOn,r64)
        END IF
    CASE(Coil_HeatingWaterToAirHPSimple)

        IF(PartLoadRatio > 0.0d0 .AND. UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac > 0.0d0 .AND. &
           UnitarySystem(UnitarySysNum)%FanOpMode == CycFanCycCoil)THEN
          OnOffFanPartLoadFraction = PartLoadRatio/UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac
        END IF

        CALL SimWatertoAirHPSimple(Blank, UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                   UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand, dummy, &
                                   UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac, &
                                   UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                   UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                   CompOn, PartLoadRatio, FirstHVACIteration)
        UnitarySystem(UnitarySysNum)%HeatCompPartLoadRatio = PartLoadRatio*REAL(CompOn,r64)

    CASE(Coil_HeatingWaterToAirHP)

        CALL HeatPumpRunFrac(UnitarySysNum,PartLoadRatio,errflag,UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac)

        IF(PartLoadRatio > 0.0d0 .AND. UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac > 0.0d0 .AND. &
           UnitarySystem(UnitarySysNum)%FanOpMode == CycFanCycCoil)THEN
          OnOffFanPartLoadFraction = PartLoadRatio/UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac
        END IF

        CALL SimWatertoAirHP(Blank, UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
              UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow,UnitarySystem(UnitarySysNum)%FanOpMode,&
              FirstHVACIteration,UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac,&
              UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
              UnitarySystem(UnitarySysNum)%HPTimeConstant, &
              UnitarySystem(UnitarySysNum)%FanDelayTime, &
              UnitarySystem(UnitarySysNum)%InitHeatPump, &
              UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand, &
              dummy,CompOn, PartLoadRatio)
        UnitarySystem(UnitarySysNum)%HeatCompPartLoadRatio = PartLoadRatio*REAL(CompOn,r64)

    CASE DEFAULT
          CALL ShowFatalError('CalcUnitaryHeatingSystem: Invalid Unitary System coil type = '//  &
                              TRIM(cAllCoilTypes(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)))

  END SELECT

  UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac = PartLoadRatio

  RETURN

END SUBROUTINE CalcUnitaryHeatingSystem

SUBROUTINE CalcUnitarySuppHeatingSystem(UnitarySysNum, FirstHVACIteration, PartLoadRatio, SuppCoilLoad)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine manages supplemental heater simulation.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE HeatingCoils,     ONLY: SimulateHeatingCoilComponents
  USE WaterCoils,       ONLY: SimulateWaterCoilComponents
  USE SteamCoils,       ONLY: SimulateSteamCoilComponents
  USE General,          ONLY: SolveRegulaFalsi

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)          :: UnitarySysNum    ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL, INTENT(IN)          :: FirstHVACIteration  ! True when first HVAC iteration
  REAL(R64), INTENT(IN)        :: PartLoadRatio       ! coil operating part-load ratio
  REAL(r64), OPTIONAL, INTENT(IN) :: SuppCoilLoad     ! adjusted supp coil load when outlet temp exceeds max (W)

          ! SUBROUTINE PARAMETER DEFINITIONS:
  INTEGER, PARAMETER   :: MaxIte    = 500     ! Maximum number of iterations for solver
  REAL(r64), PARAMETER :: Acc       = 1.d-3   ! Accuracy of solver result

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName              ! Name of Unitary System object
  REAL(r64)                     :: SuppHeatCoilLoad      ! load passed to supplemental heating coil (W)
  REAL(r64)                     :: QActual               ! actual coil output (W)
  REAL(r64)                     :: mdot                  ! water coil water mass flow rate (kg/s)
  REAL(r64), DIMENSION(5)       :: Par                   ! Parameter array passed to solver
  INTEGER                       :: SolFla                ! Flag of solver, num iterations if >0, else error index
  REAL(r64)                     :: PartLoadFrac          ! temporary PLR variable


! work is needed to figure out how to adjust other coil types if outlet temp exceeds maximum
! this works for gas and electric heating coils
  CompName = UnitarySystem(UnitarySysNum)%SuppHeatCoilName
  IF(OutDryBulbTemp .LE. UnitarySystem(UnitarySysNum)%MaxOATSuppHeat .OR. &
     (MoistureLoad < 0.0d0 .AND. UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac > 0.0d0))THEN
    IF(PRESENT(SuppCoilLoad))THEN
      SuppHeatCoilLoad = SuppCoilLoad
    ELSE
      SuppHeatCoilLoad = UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity*PartLoadRatio
    END IF
  ELSE
    SuppHeatCoilLoad = 0.0d0
  END IF

  SELECT CASE(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num)

    CASE (Coil_HeatingGas,Coil_HeatingElectric)
      SELECT CASE(UnitarySystem(UnitarySysNum)%ControlType)
        CASE(SetPointBased)
          CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
                                SuppHeat=.TRUE., &
                                FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                PartLoadRatio=PartLoadRatio)
        CASE DEFAULT
          CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
                                SuppHeat=.TRUE., &
                                QCoilReq=SuppHeatCoilLoad, &
                                FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                PartLoadRatio=PartLoadRatio)
      END SELECT
    CASE (Coil_HeatingDesuperheater)
        CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
                                SuppHeat=.TRUE., &
                                QCoilReq=SuppHeatCoilLoad, &
                                FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                PartLoadRatio=PartLoadRatio)

    CASE (Coil_HeatingWater)
      IF(PRESENT(SuppCoilLoad))THEN
        IF(SuppHeatCoilLoad > 0.0d0)THEN
          ! see if HW coil has enough capacity to meet the load
          mdot = MIN(Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
                 UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow)
          Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode)%MassFlowRate = mdot
          !     simulate water coil to find operating capacity
          CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%SuppHeatCoilName,FirstHVACIteration, &
                                           UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, QActual, &
                                           FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                           PartLoadRatio=PartLoadRatio)
          IF(QActual > SuppHeatCoilLoad)THEN
            Par(1) = REAL(UnitarySysNum,r64)
            IF (FirstHVACIteration) THEN
              Par(2) = 1.0d0
            ELSE
              Par(2) = 0.0d0
            END IF
            Par(3) = SuppHeatCoilLoad
            Par(4) = 1.0d0 ! SuppHeatingCoilFlag
            Par(5) = 1.0d0 ! Load based control
            CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, HotWaterHeatingCoilResidual, 0.0d0,   &
                                        1.0d0, Par)
            UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac = PartLoadFrac
          ELSE
            UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac = 1.0d0
          END IF
        END IF
      ELSE
        mdot = MIN(Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
                 UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow * PartLoadRatio)
        Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode)%MassFlowRate = mdot

        CALL SimulateWaterCoilComponents(CompName,FirstHVACIteration, &
                                           UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,  &
                                           QActual, UnitarySystem(UnitarySysNum)%FanOpMode, &
                                           PartLoadRatio)
      END IF
    CASE (Coil_HeatingSteam)
        mdot = MIN(Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
                 UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow * PartLoadRatio)
        Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode)%MassFlowRate = mdot
        CALL SimulateSteamCoilComponents(CompName, FirstHVACIteration, &
                                           SuppHeatCoilLoad, &
                                           UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
                                           FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode, &
                                           PartLoadRatio = PartLoadRatio)

    CASE DEFAULT

  END SELECT

!  UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac = PartLoadRatio

  RETURN

END SUBROUTINE CalcUnitarySuppHeatingSystem

SUBROUTINE CalcUnitarySuppSystemtoSP(UnitarySysNum, FirstHVACIteration)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine manages supplemental heater component simulation for setpoint based operation scheme.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE HeatingCoils,    ONLY: SimulateHeatingCoilComponents
  USE WaterCoils,      ONLY: SimulateWaterCoilComponents
  USE SteamCoils,      ONLY: SimulateSteamCoilComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)          :: UnitarySysNum    ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL, INTENT(IN)          :: FirstHVACIteration  ! True when first HVAC iteration

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName              ! Name of Unitary System object
  REAL(r64)                     :: QActual

  CompName = UnitarySystem(UnitarySysNum)%SuppHeatCoilName

  SELECT CASE(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num)

    CASE (Coil_HeatingGas,Coil_HeatingElectric)
      CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
!                                QCoilReq=(UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity* &
!                                          UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac), &
                                FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                PartLoadRatio=UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac)

    CASE (Coil_HeatingDesuperheater )
      CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
                                FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode, &
                                PartLoadRatio=UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac)

    CASE (Coil_HeatingWater)
      CALL SimulateWaterCoilComponents(CompName,FirstHVACIteration, &
                                       UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,  &
                                       QActual, UnitarySystem(UnitarySysNum)%FanOpMode, &
                                       UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac)

    CASE (Coil_HeatingSteam)
      CALL SimulateSteamCoilComponents(CompName, FirstHVACIteration, &
                                       QCoilReq=(UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity* &
                                       UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac), &
                                       CompIndex = UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
                                       FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode, &
                                       PartLoadRatio = UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac)

    CASE DEFAULT

  END SELECT

  RETURN

END SUBROUTINE CalcUnitarySuppSystemtoSP

SUBROUTINE ControlCoolingSystem(UnitarySysNum, FirstHVACIteration, HXUnitOn)
          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          !  Simulate the coil object at the required PLR.

          ! METHODOLOGY EMPLOYED:
          !  Calculate operating PLR and adjust speed when using multispeed coils.
          !  Meet moisture load if required to do so.

          ! REFERENCES:
          !  na

          ! USE STATEMENTS:
  USE DataAirLoop,     ONLY: LoopDXCoilRTF
  USE Psychrometrics , ONLY: PsyHFnTdbW, PsyTdpFnWPb
  USE General,         ONLY: SolveRegulaFalsi, RoundSigDigits
  USE DXCoils,         ONLY: SimDXCoil, SimDXCoilMultiSpeed, DXCoilOutletTemp, SimDXCoilMultiMode, DXCoilOutletHumRat
  USE HVACHXAssistedCoolingCoil, ONLY: SimHXAssistedCoolingCoil, HXAssistedCoilOutletTemp, HXAssistedCoilOutletHumRat
  USE WaterCoils,      ONLY: SimulateWaterCoilComponents
  USE PlantUtilities,  ONLY: SetComponentFlowRate
  USE WatertoAirHeatPumpSimple,  ONLY: SimWatertoAirHPSimple
  USE WatertoAirHeatPump,        ONLY: SimWaterToAirHP
  USE VariableSpeedCoils,        ONLY: SimVariableSpeedCoils, VarSpeedCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER,  Intent(In)    :: UnitarySysNum           ! index to Unitary System
  LOGICAL,  Intent(In)    :: FirstHVACIteration      ! First HVAC iteration flag
  LOGICAL,  Intent(InOut) :: HXUnitOn                ! flag to enable heat exchanger heat recovery

          ! SUBROUTINE PARAMETER DEFINITIONS:
  INTEGER, PARAMETER   :: MaxIte    = 500     ! Maximum number of iterations for solver
  REAL(r64), PARAMETER :: Acc       = 1.d-3   ! Accuracy of solver result
  REAL(r64), PARAMETER :: HumRatAcc = 1.d-6   ! Accuracy of solver result

          ! INTERFACE BLOCK SPECIFICATIONS
          !  na

          ! DERIVED TYPE DEFINITIONS
          !  na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName  ! Name of the DX cooling coil
!  REAL(r64)           :: NoOutput            ! Sensible capacity (outlet - inlet) when the compressor is off
  REAL(r64)           :: FullOutput          ! Sensible capacity (outlet - inlet) when the compressor is on
  REAL(r64)           :: ReqOutput           ! Sensible capacity (outlet - inlet) required to meet load or setpoint temperature
  Integer             :: InletNode           ! Inlet node number of the DX cooling coil
  Integer             :: OutletNode          ! Outlet node number of the DX cooling coil
  Integer             :: ControlNode         ! The node number where a setpoint is placed to control the DX cooling coil
  REAL(r64)           :: PartLoadFrac        ! The part-load fraction of the compressor
  REAL(r64)           :: SpeedRatio          ! SpeedRatio = (CompressorSpeed - CompressorSpeedMin) /
                                             !              (CompressorSpeedMax - CompressorSpeedMin)
                                             ! for variable speed or 2 speed compressors
  REAL(r64)           :: CycRatio            ! Cycling part-load ratio for variable speed or 2 speed compressors
  REAL(r64)           :: DesOutTemp          ! Desired outlet temperature of the DX cooling coil
  REAL(r64)           :: DesOutHumRat        ! Desired outlet humidity ratio of the DX cooling coil
  REAL(r64)           :: OutletTempDXCoil    ! Actual outlet temperature of the DX cooling coil
  REAL(r64)           :: OutletHumRatLS      ! Actual outlet humrat of the variable speed DX cooling coil at low speed
  REAL(r64)           :: OutletHumRatHS      ! Actual outlet humrat of the variable speed DX cooling coil at high speed
  REAL(r64)           :: OutletHumRatDXCoil  ! Actual outlet humidity ratio of the DX cooling coil
  INTEGER             :: SolFla              ! Flag of solver, num iterations if >0, else error index
  INTEGER             :: SolFlaLat           ! Flag of solver for dehumid calculations
  REAL(r64), DIMENSION(8)  :: Par                 ! Parameter array passed to solver
  LOGICAL             :: SensibleLoad        ! True if there is a sensible cooling load on this system
  LOGICAL             :: LatentLoad          ! True if there is a latent   cooling load on this system
  INTEGER             :: DehumidMode         ! dehumidification mode (0=normal, 1=enhanced)
  INTEGER             :: FanOpMode           ! Supply air fan operating mode
  REAL(r64)           :: TempMinPLR          ! Used to find latent PLR when max iterations exceeded
  REAL(r64)           :: TempMaxPLR          ! Used to find latent PLR when max iterations exceeded
  REAL(r64)           :: TempOutletTempDXCoil   ! Used to find latent PLR when max iterations exceeded
  REAL(r64)           :: TempOutletHumRatDXCoil ! Used to find latent PLR when max iterations exceeded
  REAL(r64)           :: NoLoadHumRatOut     ! DX coil outlet air humidity ratio with comprssor off
  REAL(r64)           :: FullLoadHumRatOut   ! DX coil outlet air humidity ratio with comprssor full on
  REAL(r64)           :: WSHPRuntimeFrac            ! Run time fraction of water to air hp
  REAL(r64)           :: dummy               ! dummy variable for heating latent demand
  REAL(R64)           :: OnOffAirFlowRatio
  REAL(R64)           :: OutletTemp
  INTEGER             :: SpeedNum
  REAL(R64)           :: LoopDXCoilMaxRTFSave ! Used to find RTF of DX heating coils without overwriting globabl variable
  REAL(r64)           :: NoLoadTempOut       ! saves coil off outlet temp

  ! Set local variables
  ! Retrieve the load on the controlled zone
  OutletNode   = UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum
  InletNode    = UnitarySystem(UnitarySysNum)%CoolCoilInletNodeNum
  ControlNode  = UnitarySystem(UnitarySysNum)%SystemCoolControlNodeNum
  DesOutTemp   = UnitarySystem(UnitarySysNum)%DesiredOutletTemp
  DesOutHumRat = UnitarySystem(UnitarySysNum)%DesiredOutletHumRat
  LoopDXCoilMaxRTFSave=LoopDXCoilRTF
  LoopDXCoilRTF=0.0d0

  CompName     = UnitarySystem(UnitarySysNum)%CoolingCoilName
  FanOpMode    = UnitarySystem(UnitarySysNum)%FanOpMode
  SpeedRatio   = 0.0d0
  CycRatio     = 0.0d0
  PartLoadFrac = 0.0d0
  DehumidMode  = 0
  SensibleLoad = .FALSE.
  LatentLoad   = .FALSE.
  WSHPRuntimeFrac = 0.0d0
  Dummy = 0.0d0
  SolFla = 0.0d0
  SolFlaLat = 0.0d0
  NoLoadTempOut = 0.0d0
  NoLoadHumRatOut = 0.0d0

! Check the dehumidification control type. IF it's multimode, turn off the HX to find the sensible PLR. Then check to
! see if the humidity load is met without the use of the HX. Always run the HX for the other modes.
  IF (UnitarySystem(UnitarySysNum)%DehumidControlType_Num .NE. DehumidControl_Multimode)THEN
    HXUnitOn = .TRUE.
  ELSE
    HXUnitOn = .FALSE.
  END IF

  ! IF DXCoolingSystem is scheduled on and there is flow
  IF((GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%SysAvailSchedPtr) .gt. 0.0d0) .and. &
      GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%CoolingCoilAvailSchPtr) > 0.0d0 .AND. &
     (Node(InletNode)%MassFlowRate .gt. MinAirMassFlow) .AND. UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac == 0.0d0) THEN

    ! Determine if there is a sensible load on this system (aren't the first 2 tests redundant?)
    IF((Node(InletNode)%Temp > DesOutTemp) .and. &
       (ABS(Node(InletNode)%Temp - DesOutTemp) .gt. TempControlTol) ) SensibleLoad = .TRUE.

    ! Determine if there is a latent load on this system - for future use to serve latent-only loads
    IF(Node(InletNode)%HumRat > DesOutHumRat) LatentLoad = .TRUE.

    ! disable latent dehumidification if there is no sensible load and latent only is not allowed
    IF(UnitarySystem(UnitarySysNum)%RunOnLatentOnlyWithSensible .AND. .NOT. SensibleLoad)LatentLoad = .FALSE.

    ! IF DXCoolingSystem runs with a cooling load then set PartLoadFrac on Cooling System and the Mass Flow
    ! Multimode coil will switch to enhanced dehumidification IF available and needed, but it
    ! still runs to meet the sensible load. Multimode applies to Multimode or HXAssistedCooling coils.
    IF ((SensibleLoad .and. UnitarySystem(UnitarySysNum)%RunOnSensibleLoad) .OR. &
        (LatentLoad .and. UnitarySystem(UnitarySysNum)%RunOnLatentLoad)) THEN
      ! calculate sensible PLR, don't care IF latent is true here but need to gaurd for
      ! when LatentLoad=TRUE and SensibleLoad=FALSE
      ReqOutput = Node(InletNode)%MassFlowRate *  &
                    (PsyHFnTdbW(DesOutTemp,Node(OutletNode)%HumRat) - &
                     PsyHFnTdbW(Node(InletNode)%Temp,Node(OutletNode)%HumRat))

      PartLoadFrac = 0.0d0

      SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

        CASE (CoilDX_CoolingSingleSpeed)  ! COIL:DX:COOLINGBYPASSFACTOREMPIRICAL
          UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

          CALL SimDXCoil(CompName,On,FirstHVACIteration,PartLoadFrac,UnitarySystem(UnitarySysNum)%CoolingCoilIndex,FanOpMode)

        CASE (CoilDX_CoolingHXAssisted, CoilWater_CoolingHXAssisted)  ! CoilSystem:Cooling:DX:HeatExchangerAssisted

          IF(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode .GT. 0) &
               Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode)%MassFlowRate = 0.0d0

          CALL SimHXAssistedCoolingCoil(CompName,FirstHVACIteration,On,PartLoadFrac, &
                                        UnitarySystem(UnitarySysNum)%CoolingCoilIndex, FanOpMode, &
                                        HXUnitEnable=HXUnitOn,EconomizerFlag=EconomizerFlag)
          IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num==CoilDX_CoolingHXAssisted) &
               UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac
        CASE (CoilDX_CoolingTwoSpeed)

          CALL SimDXCoilMultiSpeed(CompName,0.0d0,PartLoadFrac,UnitarySystem(UnitarySysNum)%CoolingCoilIndex)

        CASE (CoilDX_MultiSpeedCooling, Coil_CoolingAirToAirVariableSpeed, Coil_CoolingWaterToAirHPVSEquationFit)

          CALL SimMultiSpeedCoils(UnitarySysNum, FirstHVACIteration, SensibleLoad, LatentLoad, PartLoadFrac, &
                                  CoolingCoil)

        CASE (CoilDX_CoolingTwoStageWHumControl) ! Coil:Cooling:DX:TwoStageWithHumidityControlMode

          CALL SimDXCoilMultiMode(CompName,On,FirstHVACIteration,PartLoadFrac,DehumidMode,  &
                                  UnitarySystem(UnitarySysNum)%CoolingCoilIndex,FanOpMode)
          UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac
        CASE (Coil_CoolingWater, Coil_CoolingWaterDetailed)  ! COIL:COOLING:WATER

          CALL SimWaterCoils(UnitarySysNum, FirstHVACIteration, PartLoadFrac, CoolingCoil)

        CASE(Coil_CoolingWaterToAirHPSimple)

          CALL SimWatertoAirHPSimple(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, ReqOutput, Dummy, &
                                       FanOpMode,WSHPRuntimeFrac, UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                       UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                       0, PartLoadFrac, FirstHVACIteration)

        CASE(Coil_CoolingWaterToAirHP)

          CALL SimWatertoAirHP(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                 UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow,FanOpMode, &
                                 FirstHVACIteration,WSHPRuntimeFrac,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                 UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                 UnitarySystem(UnitarySysNum)%InitHeatPump, ReqOutput,Dummy,0, PartLoadFrac)
        CASE DEFAULT


      END SELECT

!      NoOutput = Node(InletNode)%MassFlowRate *  &
!                   (PsyHFnTdbW(Node(OutletNode)%Temp,Node(OutletNode)%HumRat)  &
!                    - PsyHFnTdbW(Node(InletNode)%Temp,Node(OutletNode)%HumRat))
      NoLoadTempOut = Node(OutletNode)%Temp
      NoLoadHumRatOut = Node(OutletNode)%HumRat

!     Changed logic to use temperature instead of load. The Psyc calcs can cause slight errors.
!     For example it's possible that (NoOutput-ReqOutput) > Acc while (Node(OutletNode)%Temp-DesOutTemp) is not
!     This can (and did) lead to RegulaFalsi errors

!      IF ((NoOutput-ReqOutput) .LT. Acc) THEN
!     IF outlet temp at no load is lower than DesOutTemp (set point), do not operate the coil
      IF ((NoLoadTempOut-DesOutTemp) .LT. Acc) THEN
        PartLoadFrac = 0.0d0
      ELSE IF(SensibleLoad)THEN ! need to turn on compressor to see if load is met
        PartLoadFrac = 1.0d0
        WSHPRuntimeFrac = 1.0d0
        SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

          CASE (CoilDX_CoolingSingleSpeed)  ! COIL:DX:COOLINGBYPASSFACTOREMPIRICAL

            CALL SimDXCoil(CompName,On,FirstHVACIteration,PartLoadFrac,UnitarySystem(UnitarySysNum)%CoolingCoilIndex,FanOpMode)
            UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

          CASE (CoilDX_CoolingHXAssisted,CoilWater_CoolingHXAssisted)  ! CoilSystem:Cooling:DX:HeatExchangerAssisted

            IF(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode .GT. 0) &
                 Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode)%MassFlowRate = &
                    MAX(0.0d0,UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow)
            CALL SimHXAssistedCoolingCoil(CompName,FirstHVACIteration,On,PartLoadFrac, &
                                          UnitarySystem(UnitarySysNum)%CoolingCoilIndex, FanOpMode, &
                                          HXUnitEnable=HXUnitOn,EconomizerFlag=EconomizerFlag)

            IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num==CoilDX_CoolingHXAssisted) &
                 UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

          CASE (CoilDX_CoolingTwoSpeed)

            CycRatio = 1.0d0
            DO SpeedNum = 1, UnitarySystem(UnitarySysNum)%NumOfSpeedCooling
              SpeedRatio = REAL(SpeedNum,r64) - 1.0d0
              CALL SimDXCoilMultiSpeed(CompName,SpeedRatio,CycRatio,UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
              OutletTemp = DXCoilOutletTemp(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
              IF (OutletTemp < DesOutTemp .AND. SensibleLoad) EXIT ! this isn't going to work IF dehumidIFying
            END DO

          CASE (CoilDX_MultiSpeedCooling, Coil_CoolingAirToAirVariableSpeed, Coil_CoolingWaterToAirHPVSEquationFit)

            CycRatio = 1.0d0
            DO SpeedNum = 1, UnitarySystem(UnitarySysNum)%NumOfSpeedCooling
              CALL SimMultiSpeedCoils(UnitarySysNum, FirstHVACIteration, SensibleLoad, LatentLoad, PartLoadFrac, &
                                      CoolingCoil, SpeedNum)
              OutletTemp = Node(OutletNode)%Temp
              SpeedRatio = REAL(SpeedNum,r64) - 1.0d0
              IF (OutletTemp < DesOutTemp .AND. SensibleLoad) EXIT
            END DO

          CASE (CoilDX_CoolingTwoStageWHumControl) ! Coil:Cooling:DX:TwoStageWithHumidityControlMode

            CALL SimDXCoilMultiMode(CompName,On,FirstHVACIteration,PartLoadFrac,DehumidMode,  &
                                    UnitarySystem(UnitarySysNum)%CoolingCoilIndex,FanOpMode)
            UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

          CASE (Coil_CoolingWater, Coil_CoolingWaterDetailed)  ! COIL:COOLING:WATER

            CALL SimWaterCoils(UnitarySysNum, FirstHVACIteration, PartLoadFrac, CoolingCoil)

          CASE(Coil_CoolingWaterToAirHPSimple)

            CALL SimWatertoAirHPSimple(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, ReqOutput, Dummy, &
                                       FanOpMode,WSHPRuntimeFrac, UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                       UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                       0, PartLoadFrac, FirstHVACIteration)

          CASE(Coil_CoolingWaterToAirHP)

            CALL SimWatertoAirHP(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                   UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow,FanOpMode, &
                                   FirstHVACIteration,WSHPRuntimeFrac,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                   UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                   UnitarySystem(UnitarySysNum)%InitHeatPump, ReqOutput,Dummy,0, PartLoadFrac)
          CASE DEFAULT


        END SELECT

        FullOutput = Node(InletNode)%MassFlowRate *  &
                   (PsyHFnTdbW(Node(OutletNode)%Temp,Node(OutletNode)%HumRat)  &
                    - PsyHFnTdbW(Node(InletNode)%Temp,Node(OutletNode)%HumRat))

        FullLoadHumRatOut = Node(OutletNode)%HumRat


!        IF ((FullOutput - ReqOutput) .GT. Acc) THEN ! old method
!        IF ((Node(OutletNode)%Temp-DesOutTemp) .GT. Acc) THEN ! new method gets caught when temps are very close
        IF (Node(OutletNode)%Temp .GT. DesOutTemp-Acc) THEN
          PartLoadFrac = 1.0d0

        ELSE
          SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

            CASE (CoilDX_CoolingSingleSpeed)  ! COIL:DX:COOLINGBYPASSFACTOREMPIRICAL

              Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
              Par(2) = DesOutTemp
              Par(5) = REAL(FanOpMode,r64)
              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, DOE2DXCoilResidual, 0.0d0,   &
                                    1.0d0, Par)
              UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

            CASE (CoilDX_CoolingHXAssisted,CoilWater_CoolingHXAssisted)  ! CoilSystem:Cooling:DX:HeatExchangerAssisted

                Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                Par(2) = DesOutTemp
              ! FirstHVACIteration is a logical, Par is REAL(r64), so make TRUE = 1 and FALSE = 0
                IF(FirstHVACIteration)THEN
                  Par(3) = 1.0d0
                ELSE
                  Par(3) = 0.0d0
                END IF
                IF(HXUnitOn)THEN
                  Par(4) = 1.0d0
                ELSE
                  Par(4) = 0.0d0
                END IF
                Par(5) = REAL(FanOpMode,r64)
                Par(6) = REAL(UnitarySysNum,r64)
                CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, HXAssistedCoolCoilTempResidual, 0.0d0,   &
                                      1.0d0, Par)
                IF (SolFla == -1) THEN

!                 RegulaFalsi may not find sensible PLR when the latent degradation model is used.
!                 IF iteration limit is exceeded, find tighter boundary of solution and repeat RegulaFalsi
                  TempMaxPLR = -0.1d0
                  TempOutletTempDXCoil = Node(InletNode)%Temp
                  DO WHILE((TempOutletTempDXCoil-DesOutTemp) .GT. 0.0d0 .AND. TempMaxPLR .LE. 1.0d0)
!                   find upper limit of PLR
                    TempMaxPLR = TempMaxPLR + 0.1d0
                    CALL SimHXAssistedCoolingCoil(CompName,FirstHVACIteration,On,TempMaxPLR, &
                                                  UnitarySystem(UnitarySysNum)%CoolingCoilIndex, FanOpMOde, &
                                                  HXUnitEnable=HXUnitOn, EconomizerFlag=EconomizerFlag)
                    TempOutletTempDXCoil = HXAssistedCoilOutletTemp(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                  END DO
                  TempMinPLR = TempMaxPLR
                  DO WHILE((TempOutletTempDXCoil-DesOutTemp) .LT. 0.0d0 .AND. TempMinPLR .GE. 0.0d0)
!                  pull upper limit of PLR DOwn to last valid limit (i.e. outlet temp still exceeds DesOutTemp)
                    TempMaxPLR = TempMinPLR
!                   find minimum limit of PLR
                    TempMinPLR = TempMinPLR - 0.01d0
                    CALL SimHXAssistedCoolingCoil(CompName,FirstHVACIteration,On,TempMinPLR, &
                                                  UnitarySystem(UnitarySysNum)%CoolingCoilIndex, FanOpMode, &
                                                  HXUnitEnable=HXUnitOn, EconomizerFlag=EconomizerFlag)
                    TempOutletTempDXCoil = HXAssistedCoilOutletTemp(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                  END DO
!                 Relax boundary slightly to assure a solution can be found using RegulaFalsi (i.e. one boundary may be
!                 very near the desired result)
                  TempMinPLR = MAX(0.0d0,(TempMinPLR - 0.01d0))
                  TempMaxPLR = MIN(1.0d0,(TempMaxPLR + 0.01d0))
!                 tighter boundary of solution has been found, CALL RegulaFalsi a second time
                  CALL SolveRegulaFalsi(Acc,MaxIte,SolFla,PartLoadFrac,HXAssistedCoolCoilTempResidual,TempMinPLR,TempMaxPLR,Par)
                  IF (SolFla == -1) THEN
                    IF(.NOT. WarmupFlag)THEN
                      IF(UnitarySystem(UnitarySysNum)%HXAssistedSensPLRIter .LT. 1)THEN
                        UnitarySystem(UnitarySysNum)%HXAssistedSensPLRIter = UnitarySystem(UnitarySysNum)%HXAssistedSensPLRIter+1
                        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' - Iteration limit'// &
                                              ' exceeded calculating DX unit sensible part-load ratio for unit = '// &
                                              TRIM(UnitarySystem(UnitarySysNum)%Name))
                        CALL ShowContinueError('Estimated part-load ratio   = '//RoundSigDigits((ReqOutput/FullOutput),3))
                        CALL ShowContinueError('Calculated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
                        CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation'// &
                                                        ' continues. Occurrence info: ')
                      END IF
                      CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
                          //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - Iteration limit exceeded calculating'// &
                          ' sensible part-load ratio error continues. Sensible PLR statistics follow.' &
                          ,UnitarySystem(UnitarySysNum)%HXAssistedSensPLRIterIndex,PartLoadFrac,PartLoadFrac)
                    END IF
                  ELSEIF (SolFla == -2) THEN
                    PartLoadFrac = ReqOutput/FullOutput
                    IF(.NOT. WarmupFlag)THEN
                      IF(UnitarySystem(UnitarySysNum)%HXAssistedSensPLRFail .LT. 1)THEN
                        UnitarySystem(UnitarySysNum)%HXAssistedSensPLRFail = UnitarySystem(UnitarySysNum)%HXAssistedSensPLRFail+1
                        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                                            ' - DX unit sensible part-load ratio calculation unexpectedly failed: part-load '// &
                                            'ratio limits exceeded, for unit = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                        CALL ShowContinueError('Estimated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
                        CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation'// &
                                                        ' continues. Occurrence info: ')
                      END IF
                      CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
                          //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - DX unit sensible part-load ratio calculation'// &
                          ' unexpectedly failed error continues. Sensible PLR statistics follow.' &
                          ,UnitarySystem(UnitarySysNum)%HXAssistedSensPLRFailIndex,PartLoadFrac,PartLoadFrac)
                    END IF
                  END IF
                ELSEIF (SolFla == -2) THEN
                  PartLoadFrac = ReqOutput/FullOutput
                  IF(.NOT. WarmupFlag)THEN
                    IF(UnitarySystem(UnitarySysNum)%HXAssistedSensPLRFail2 .LT. 1)THEN
                      UnitarySystem(UnitarySysNum)%HXAssistedSensPLRFail2 = UnitarySystem(UnitarySysNum)%HXAssistedSensPLRFail2+1
                      CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                                            ' - DX unit sensible part-load ratio calculation failed: part-load '// &
                                            'ratio limits exceeded, for unit = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                      CALL ShowContinueError('Estimated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
                      CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation'// &
                                                      ' continues. Occurrence info: ')
                    END IF
                    CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
                        //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - DX unit sensible part-load ratio calculation'// &
                        ' failed error continues. Sensible PLR statistics follow.' &
                        ,UnitarySystem(UnitarySysNum)%HXAssistedSensPLRFailIndex2,PartLoadFrac,PartLoadFrac)
                  END IF
                END IF
              IF(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num==CoilDX_CoolingHXAssisted) &
                   UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

            CASE (CoilDX_CoolingTwoSpeed)
              Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
              Par(2) = DesOutTemp
              ! Par(3) is only needed for variable speed coils (see DXCoilVarSpeedResidual and DXCoilCyclingResidual)
              Par(3) = UnitarySysNum
              IF(SpeedRatio == 1.0d0)THEN
                CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, SpeedRatio, DXCoilVarSpeedResidual, 0.0d0,   &
                                        1.0d0, Par)
                PartLoadFrac = SpeedRatio
              ELSE
                CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, CycRatio, DXCoilCyclingResidual, 0.0d0,   &
                                      1.0d0, Par)
                PartLoadFrac = CycRatio
              END IF

            CASE (CoilDX_MultiSpeedCooling, Coil_CoolingAirToAirVariableSpeed, Coil_CoolingWaterToAirHPVSEquationFit)

                Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                Par(2) = DesOutTemp
                Par(3) = UnitarySysNum
                ! Par(4) = CycRatio or SpeedRatio
                Par(5) = UnitarySystem(UnitarySysNum)%CoolingSpeedNum
                Par(6) = 1.0d0 ! UnitarySystem(UnitarySysNum)%FanOpMode
                Par(7) = 1.0d0 ! CompOp
                Par(8) = ReqOutput

              IF (SpeedRatio == 1.0d0) THEN
                Par(4) = CycRatio
                CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, SpeedRatio, DXCoilVarSpeedResidual, 0.0d0,   &
                                              1.0d0, Par)
                UnitarySystem(UnitarySysNum)%CoolingCycRatio = SpeedRatio
                UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac = SpeedRatio
                CALL CalcPassiveSystem(UnitarySysNum, FirstHVACIteration)
                PartLoadFrac = SpeedRatio
              ELSE
                SpeedRatio = 0.0d0
                UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = SpeedRatio
                Par(4) = SpeedRatio

                CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, CycRatio, DXCoilCyclingResidual, 0.0d0,   &
                                                1.0d0, Par)
                UnitarySystem(UnitarySysNum)%CoolingCycRatio = CycRatio
                UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac = CycRatio
                CALL CalcPassiveSystem(UnitarySysNum, FirstHVACIteration)
                PartLoadFrac = CycRatio
              END IF

            CASE (CoilDX_CoolingTwoStageWHumControl) ! Coil:Cooling:DX:TwoStageWithHumidityControlMode

              Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
              Par(2) = DesOutTemp
              ! dehumidification mode = 0 for normal mode, 1+ for enhanced mode
              Par(3) = REAL(DehumidMode,r64)
              Par(4) = REAL(FanOpMode,r64)
              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, MultiModeDXCoilResidual, 0.0d0,   &
                                    1.0d0, Par)
              UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

            CASE (Coil_CoolingWater, Coil_CoolingWaterDetailed)  ! COIL:COOLING:WATER

              Par(1) = REAL(UnitarySysNum,r64)
              IF (FirstHVACIteration) THEN
                Par(2) = 1.0d0
              ELSE
                Par(2) = 0.0d0
              END IF
              Par(3) = DesOutTemp
              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, CoolWaterTempResidual, 0.0d0,   &
                                            1.0d0, Par)

            CASE(Coil_CoolingWaterToAirHPSimple, Coil_CoolingWaterToAirHP)
              Par(1) = REAL(UnitarySysNum,r64)
              IF (FirstHVACIteration) THEN
                Par(2) = 1.0d0
              ELSE
                Par(2) = 0.0d0
              END IF
              Par(3) = DesOutTemp
              Par(4) = ReqOutput

              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, CoolWatertoAirHPTempResidual, 0.0d0,   &
                                            1.0d0, Par)

            CASE DEFAULT
              CALL ShowMessage(' For :'//TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//'="'// &
                               TRIM(UnitarySystem(UnitarySysNum)%Name)//'"')
              CALL ShowFatalError('ControlCoolingSystem: Invalid cooling coil type = '//  &
                               TRIM(CALLCoilTypes(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)))

          END SELECT

        END IF
      END IF

!     IF system does not operate to meet sensible load, use no load humidity ratio to test against humidity setpoint,
!     ELSE use operating humidity ratio to test against humidity setpoint
      IF (PartLoadFrac .EQ. 0.0d0)THEN
        OutletHumRatDXCoil = NoLoadHumRatOut
      ELSE
        OutletHumRatDXCoil = Node(OutletNode)%HumRat
      END IF

      ! IF humidity setpoint is not satisfied and humidity control type is MultiMode,
      ! then enable heat exchanger and run to meet sensible load

      IF (( OutletHumRatDXCoil > (DesOutHumRat + HumRatAcc)) .AND. (PartLoadFrac .LT. 1.0d0) .AND. &
          (UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_Multimode)) THEN

        SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

          CASE (CoilDX_CoolingHXAssisted)  ! CoilSystem:Cooling:DX:HeatExchangerAssisted
            ! Determine required part load when heat exchanger is ON
            HXUnitOn = .TRUE.
            PartLoadFrac = 1.0d0
            CALL SimHXAssistedCoolingCoil(CompName,FirstHVACIteration,On,PartLoadFrac, &
                                            UnitarySystem(UnitarySysNum)%CoolingCoilIndex, FanOpMode, &
                                            HXUnitEnable=HXUnitOn, EconomizerFlag=EconomizerFlag)

            OutletTempDXCoil = HXAssistedCoilOutletTemp(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)

        !               FullOutput will be different than the FullOutput determined above during sensible PLR calculations
            FullOutput = Node(InletNode)%MassFlowRate *  &
                        (PsyHFnTdbW(Node(OutletNode)%Temp,Node(OutletNode)%HumRat)  &
                        - PsyHFnTdbW(Node(InletNode)%Temp,Node(OutletNode)%HumRat))

        !   Check to see if the system can meet the load with the compressor off
        !   If NoOutput is lower than (more cooling than required) or very near the ReqOutput, do not run the compressor
            IF ((NoLoadTempOut-DesOutTemp) .LT. Acc) THEN
                PartLoadFrac = 0.0d0
        !          OutletTempDXCoil is the full capacity outlet temperature at PartLoadFrac = 1 from the CALL above.
        !          if this temp is greater than or very near the desired outlet temp, then run the compressor at PartLoadFrac = 1.
!            ELSEIF ((OutletTempDXCoil > DesOutTemp) .OR. ABS(OutletTempDXCoil - DesOutTemp) .LE. (Acc*2.0d0)) THEN
            ELSEIF (OutletTempDXCoil > DesOutTemp - (Acc*2.0d0)) THEN
                PartLoadFrac = 1.0d0
            ELSE
                Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                Par(2) = DesOutTemp
                ! FirstHVACIteration is a logical, Par is REAL(r64), so make TRUE = 1.0 and FALSE = 0.0
                IF(FirstHVACIteration)THEN
                Par(3) = 1.0d0
                ELSE
                Par(3) = 0.0d0
                END IF
                IF(HXUnitOn)THEN
                Par(4) = 1.0d0
                ELSE
                Par(4) = 0.0d0
                END IF
                Par(5) = REAL(FanOpMode,r64)
                CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, HXAssistedCoolCoilTempResidual, 0.0d0,   &
                                            1.0d0, Par)
            END IF
            UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

          CASE (CoilDX_CoolingTwoStageWHumControl) ! Coil:Cooling:DX:TwoStageWithHumidityControlMode
                                        ! formerly (v3 and beyond) COIL:DX:MULTIMODE:COOLINGEMPIRICAL)

               ! Get full load result
                PartLoadFrac = 1.0d0
                DehumidMode  = 1
                UnitarySystem(UnitarySysNum)%dehumidificationMode = DehumidMode
                CALL SimDXCoilMultiMode(CompName,On,FirstHVACIteration,PartLoadFrac,DehumidMode,  &
                                        UnitarySystem(UnitarySysNum)%CoolingCoilIndex,FanOpMode)
                FullOutput = Node(InletNode)%MassFlowRate *  &
                             (PsyHFnTdbW(Node(OutletNode)%Temp,Node(InletNode)%HumRat)  &
                              - PsyHFnTdbW(Node(InletNode)%Temp,Node(InletNode)%HumRat))

                ! Since we are cooling, we expect FullOutput to be < 0 and FullOutput < NoCoolOutput
                ! Check that this is the case; IF not set PartLoadFrac = 0.0 (off) and return
                ! Calculate the part load fraction
                IF (FullOutput .GE. 0) THEN
                  PartLoadFrac = 0.0d0
                ELSE
                  OutletTempDXCoil = DXCoilOutletTemp(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                  OutletHumRatDXCoil = DXCoilOutletHumRat(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                  ! If sensible load and setpoint cannot be met, set PLR = 1. if no sensible load and
                  ! latent load exists and setpoint cannot be met, set PLR = 1.
! why is our logic different? Did we figure something out that reduced the logic?
!                  IF ((SensibleLoad .and. LatentLoad .AND. .NOT. UnitarySystem(UnitarySysNum)%RunOnLatentLoad .AND. &
!                       OutletHumRatDXCoil >= DesOutHumRat)) THEN
                  IF ((OutletTempDXCoil > (DesOutTemp-(Acc*2.0d0)) .AND. SensibleLoad .and.   &
                       UnitarySystem(UnitarySysNum)%RunOnSensibleLoad) .OR. &
                      (OutletHumRatDXCoil > (DesOutHumRat-(HumRatAcc*2.0d0)) .AND. &
                      .NOT. SensibleLoad .AND. LatentLoad .AND. UnitarySystem(UnitarySysNum)%RunOnLatentLoad)) THEN
                    PartLoadFrac = 1.0d0
!                  ELSEIF ((SensibleLoad .and. LatentLoad .AND. .NOT. UnitarySystem(UnitarySysNum)%RunOnLatentLoad .AND. &
!                       OutletHumRatDXCoil < DesOutHumRat)) THEN
                  ELSE IF (.NOT. SensibleLoad .AND. &
                      (OutletHumRatDXCoil < DesOutHumRat .AND. LatentLoad .AND. UnitarySystem(UnitarySysNum)%RunOnLatentLoad)) THEN
                    PartLoadFrac = ReqOutput/FullOutput
                    Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                    Par(2) = DesOutHumRat
                    ! dehumidification mode = 0 for normal mode, 1+ for enhanced mode
                    Par(3) = REAL(DehumidMode,r64)
                    Par(4) = REAL(FanOpMode,r64)
                    CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, MultiModeDXCoilHumRatResidual, &
                                          0.0d0, 1.0d0, Par)
                  ELSE ! must be a sensible load so find PLR
                    PartLoadFrac = ReqOutput/FullOutput
                    Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                    Par(2) = DesOutTemp
                    ! Dehumidification mode = 0 for normal mode, 1+ for enhanced mode
                    Par(3) = REAL(DehumidMode,r64)
                    Par(4) = REAL(FanOpMode,r64)
                    CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, MultiModeDXCoilResidual, &
                                          0.0d0, 1.0d0, Par)
                  END IF
                END IF
            UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

          CASE DEFAULT

        END SELECT
      END IF ! END IF humidity ratio setpoint not met - Multimode humidity control

        ! IF humidity setpoint is not satisfied and humidity control type is CoolReheat,
        ! then overcool to meet moisture load

      IF (( OutletHumRatDXCoil > DesOutHumRat) .AND. (PartLoadFrac .LT. 1.0d0) .AND. LatentLoad .AND. &
            (UnitarySystem(UnitarySysNum)%DehumidControlType_Num .EQ. DehumidControl_CoolReheat)) THEN

!           IF NoLoadHumRatOut is lower than (more dehumidification than required) or very near the DesOutHumRat,
!           do not run the compressor
        IF ((NoLoadHumRatOut-DesOutHumRat) .LT. HumRatAcc) THEN
            PartLoadFrac = PartLoadFrac  ! keep part-load fraction from sensible calculation
!           If the FullLoadHumRatOut is greater than (insufficient dehumidification) or very near the DesOutHumRat,
!           run the compressor at PartLoadFrac = 1.
!        ELSEIF ((DesOutHumRat-FullLoadHumRatOut) .LT. HumRatAcc) THEN
        ELSEIF (FullLoadHumRatOut .GT. (DesOutHumRat-HumRatAcc)) THEN
            PartLoadFrac = 1.0d0
!           ELSE find the PLR to meet the load

        ELSE

          SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

            CASE (CoilDX_CoolingSingleSpeed)  ! COIL:DX:COOLINGBYPASSFACTOREMPIRICAL

                Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                Par(2) = DesOutHumRat
                Par(5) = REAL(FanOpMode,r64)
                CALL SolveRegulaFalsi(HumRatAcc, MaxIte, SolFlaLat, PartLoadFrac, DOE2DXCoilHumRatResidual, 0.0d0,   &
                                            1.0d0, Par)
              UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

            CASE (CoilDX_CoolingHXAssisted)  ! CoilSystem:Cooling:DX:HeatExchangerAssisted

!               IF NoLoadHumRatOut is lower than (more dehumidification than required) or very near the DesOutHumRat,
!               do not run the compressor
                IF ((NoLoadHumRatOut-DesOutHumRat) .LT. HumRatAcc*2.0d0) THEN
                  PartLoadFrac = PartLoadFrac  ! keep part-load fraction from sensible calculation
!                If the FullLoadHumRatOut is greater than (insufficient dehumidification) or very near the DesOutHumRat,
!                run the compressor at PartLoadFrac = 1.
                ELSEIF ((DesOutHumRat-FullLoadHumRatOut) .LT. HumRatAcc*2.0d0) THEN
                  PartLoadFrac = 1.0d0
!               ELSE find the PLR to meet the load
                ELSE
                  Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                  Par(2) = DesOutHumRat
                  ! FirstHVACIteration is a logical, Par is REAL(r64), so make TRUE = 1 and FALSE = 0
                  IF(FirstHVACIteration)THEN
                    Par(3) = 1.0d0
                  ELSE
                    Par(3) = 0.0d0
                  END IF
                  IF(HXUnitOn)THEN
                    Par(4) = 1.0d0
                  ELSE
                    Par(4) = 0.0d0
                  END IF
                  Par(5) = REAL(FanOpMode,r64)
                  CALL SolveRegulaFalsi(HumRatAcc, MaxIte, SolFla, PartLoadFrac, HXAssistedCoolCoilHRResidual, 0.0d0,   &
                                        1.0d0, Par)
                  IF (SolFla == -1) THEN

!                   RegulaFalsi may not find latent PLR when the latent degradation model is used.
!                   IF iteration limit is exceeded, find tighter boundary of solution and repeat RegulaFalsi
                    TempMaxPLR = -0.1d0
                    TempOutletHumRatDXCoil = OutletHumRatDXCoil
                    DO WHILE((OutletHumRatDXCoil - TempOutletHumRatDXCoil) .GE. 0.0d0 .AND. TempMaxPLR .LE. 1.0d0)
!                     find upper limit of LatentPLR
                      TempMaxPLR = TempMaxPLR + 0.1d0
                      CALL SimHXAssistedCoolingCoil(CompName,FirstHVACIteration,On,TempMaxPLR, &
                                                    UnitarySystem(UnitarySysNum)%CoolingCoilIndex, FanOpMode, &
                                                    HXUnitEnable=HXUnitOn, EconomizerFlag=EconomizerFlag)
                      OutletHumRatDXCoil = HXAssistedCoilOutletHumRat(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                    END DO
                    TempMinPLR = TempMaxPLR
                    DO WHILE((OutletHumRatDXCoil - TempOutletHumRatDXCoil) .LE. 0.0d0 .AND. TempMinPLR .GE. 0.0d0)
!                     pull upper limit of LatentPLR DOwn to last valid limit (i.e. latent output still exceeds SystemMoisuterLoad)
                      TempMaxPLR = TempMinPLR
!                     find minimum limit of Latent PLR
                      TempMinPLR = TempMinPLR - 0.01d0
                      CALL SimHXAssistedCoolingCoil(CompName,FirstHVACIteration,On,TempMaxPLR, &
                                                    UnitarySystem(UnitarySysNum)%CoolingCoilIndex, FanOpMode, &
                                                    HXUnitEnable=HXUnitOn, EconomizerFlag=EconomizerFlag)
                      OutletHumRatDXCoil = HXAssistedCoilOutletHumRat(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                    END DO
!                   tighter boundary of solution has been found, CALL RegulaFalsi a second time
                    CALL SolveRegulaFalsi(HumRatAcc,MaxIte,SolFla,PartLoadFrac,HXAssistedCoolCoilHRResidual, &
                                          TempMinPLR,TempMaxPLR,Par)
                    IF (SolFla == -1) THEN
                      IF(.NOT. WarmupFlag)THEN
                        IF(UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRIter .LT. 1)THEN
                          UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRIter = &
                            UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRIter+1
                          CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                                                ' - Iteration limit exceeded calculating DX unit latent'// &
                                                ' part-load ratio for unit = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                          CALL ShowContinueError('Estimated latent part-load ratio  = '//RoundSigDigits((ReqOutput/FullOutput),3))
                          CALL ShowContinueError('Calculated latent part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
                          CALL ShowContinueErrorTimeStamp('The calculated latent part-load ratio will be used and the'// &
                                                          ' simulation continues. Occurrence info: ')
                        END IF
                        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
                            //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - Iteration limit exceeded calculating'// &
                            ' latent part-load ratio error continues. Latent PLR statistics follow.' &
                            ,UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRIterIndex,PartLoadFrac,PartLoadFrac)
                      END IF

                    ELSEIF (SolFla == -2) THEN

                      PartLoadFrac = ReqOutput/FullOutput
                      IF(.NOT. WarmupFlag)THEN
                        IF(UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRFail .LT. 1)THEN
                          UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRFail = &
                            UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRFail+1
                          CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                                         ' - DX unit latent part-load ratio calculation failed unexpectedly:'// &
                                         ' part-load ratio limits exceeded, for unit = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                          CALL ShowContinueError('Estimated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
                          CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation'// &
                                                          ' continues. Occurrence info: ')
                        END IF
                        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
                            //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - DX unit latent part-load ratio calculation'// &
                            ' failed unexpectedly error continues. Latent PLR statistics follow.' &
                            ,UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRFailIndex,PartLoadFrac,PartLoadFrac)
                      END IF
                    END IF
                  ELSEIF (SolFla == -2) THEN
                    PartLoadFrac = ReqOutput/FullOutput
                    IF(.NOT. WarmupFlag)THEN
                      IF(UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRFail2 .LT. 1)THEN
                        UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRFail2 = &
                          UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRFail2+1
                        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                                            ' - DX unit latent part-load ratio calculation failed: part-load '// &
                                             'ratio limits exceeded, for unit = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
                        CALL ShowContinueError('Estimated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
                        CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation'// &
                                                        ' continues. Occurrence info: ')
                      END IF
                      CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
                          //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - DX unit latent part-load ratio calculation'// &
                          ' failed error continues. Latent PLR statistics follow.' &
                          ,UnitarySystem(UnitarySysNum)%HXAssistedCRLatPLRFailIndex2,PartLoadFrac,PartLoadFrac)
                    END IF
                  END IF
                END IF
              UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

            CASE (CoilDX_CoolingTwoSpeed)

!               Simulate MultiSpeed DX coil at sensible result
                CALL SimDXCoilMultiSpeed(CompName,SpeedRatio,CycRatio,UnitarySystem(UnitarySysNum)%CoolingCoilIndex)

                OutletHumRatDXCoil = DXCoilOutletHumRat(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                ! IF humidity setpoint is not satisfied and humidity control type is CoolReheat,
                ! then overcool to meet moisture load

                IF (OutletHumRatDXCoil > DesOutHumRat) THEN

                  CycRatio = 0.0d0
                  SpeedRatio = 0.0d0

                  CALL SimDXCoilMultiSpeed(CompName,0.0d0,1.0d0,UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                  OutletHumRatLS = DXCoilOutletHumRat(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                  IF (OutletHumRatLS > DesOutHumRat) THEN
                    CycRatio = 1.0d0
                    CALL SimDXCoilMultiSpeed(CompName,1.0d0,1.0d0,UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                    OutletHumRatHS = DXCoilOutletHumRat(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                    IF (OutletHumRatHS < DesOutHumRat) THEN
                      Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                      Par(2) = DesOutHumRat
                      CALL SolveRegulaFalsi(HumRatAcc, MaxIte, SolFla, SpeedRatio, DXCoilVarSpeedHumRatResidual, 0.0d0, &
                                            1.0d0, Par)
                    ELSE
                      SpeedRatio = 1.0d0
                    END IF
                  ELSE
                    SpeedRatio = 0.0d0
                    Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                    Par(2) = DesOutHumRat
                    CALL SolveRegulaFalsi(HumRatAcc, MaxIte, SolFla, CycRatio, DXCoilCyclingHumRatResidual, 0.0d0, &
                                          1.0d0, Par)
                  END IF

                END IF

            CASE (CoilDX_MultiSpeedCooling, Coil_CoolingAirToAirVariableSpeed, Coil_CoolingWaterToAirHPVSEquationFit)

                IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling) THEN
                  CALL SimDXCoilMultiSpeed(CompName,SpeedRatio,CycRatio,UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                ELSE
                  CALL SimVariableSpeedCoils(CompName,UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                    UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                    UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                    1, CycRatio, OnOffAirFlowRatio,SpeedNum, SpeedRatio,ReqOutput,Dummy )
                END IF

                OutletHumRatDXCoil = DXCoilOutletHumRat(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                ! IF humidity setpoint is not satisfied and humidity control type is CoolReheat,
                ! then overcool to meet moisture load

                IF (OutletHumRatDXCoil > DesOutHumRat) THEN

                  CycRatio = 0.0d0
                  SpeedRatio = 0.0d0

                  IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling) THEN
                    CALL SimDXCoilMultiSpeed(CompName,0.0d0,1.0d0,UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                  ELSE
                    CALL SimVariableSpeedCoils(CompName,UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                 UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                 UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                 1, 1.0d0, OnOffAirFlowRatio,SpeedNum, 1.0d0,ReqOutput,Dummy )
                  END IF

                  OutletHumRatLS = DXCoilOutletHumRat(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)

                  IF (OutletHumRatLS > DesOutHumRat) THEN
                    CycRatio = 1.0d0
                    IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == CoilDX_MultiSpeedCooling) THEN
                      CALL SimDXCoilMultiSpeed(CompName,1.0d0,1.0d0,UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                    ELSE
                      CALL SimVariableSpeedCoils(CompName,UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                   UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                   UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                   1, 1.0d0, OnOffAirFlowRatio,SpeedNum, 1.0d0,ReqOutput,Dummy )
                    END IF
                    OutletHumRatHS = DXCoilOutletHumRat(UnitarySystem(UnitarySysNum)%CoolingCoilIndex)
                    IF (OutletHumRatHS < DesOutHumRat) THEN
                      Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                      Par(2) = DesOutHumRat
                      Par(3) = ReqOutput
                      CALL SolveRegulaFalsi(HumRatAcc, MaxIte, SolFla, SpeedRatio, DXCoilVarSpeedHumRatResidual, 0.0d0,   &
                                                1.0d0, Par)
                    ELSE
                      SpeedRatio = 1.0d0
                    END IF
                  ELSE
                    SpeedRatio = 0.0d0
                    Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                    Par(2) = DesOutHumRat
                    Par(3) = ReqOutput
                      CALL SolveRegulaFalsi(HumRatAcc, MaxIte, SolFla, CycRatio, DXCoilCyclingHumRatResidual, 0.0d0,   &
                                                1.0d0, Par)
                  END IF

                END IF

            CASE (CoilDX_CoolingTwoStageWHumControl) ! Coil:Cooling:DX:TwoStageWithHumidityControlMode

                Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
                Par(2) = DesOutHumRat
                ! dehumidification mode = 0 for normal mode, 1+ for enhanced mode
                Par(3) = REAL(DehumidMode,r64)
                Par(4) = REAL(FanOpMode,r64)
                CALL SolveRegulaFalsi(Acc, MaxIte, SolFlaLat, PartLoadFrac, MultiModeDXCoilHumRatResidual, 0.0d0,   &
                                            1.0d0, Par)
                UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

            CASE (Coil_CoolingWater, Coil_CoolingWaterDetailed)  ! COIL:COOLING:WATER

                Par(1) = REAL(UnitarySysNum,r64)
                IF (FirstHVACIteration) THEN
                Par(2) = 1.0d0
                ELSE
                Par(2) = 0.0d0
                END IF
                Par(3) = DesOutHumRat

                CALL SolveRegulaFalsi(HumRatAcc, MaxIte, SolFlaLat, PartLoadFrac, CoolWaterHumRatResidual, 0.0d0,   &
                                            1.0d0, Par)

            CASE(Coil_CoolingWaterToAirHPSimple, Coil_CoolingWaterToAirHP)

                Par(1) = REAL(UnitarySysNum,r64)
                IF (FirstHVACIteration) THEN
                  Par(2) = 1.0d0
                ELSE
                  Par(2) = 0.0d0
                END IF
                Par(3) = DesOutHumRat
                Par(4) = ReqOutput

                CALL SolveRegulaFalsi(HumRatAcc, MaxIte, SolFlaLat, PartLoadFrac, CoolWatertoAirHPHumRatResidual, 0.0d0,   &
                                                1.0d0, Par)

              CASE DEFAULT

            END SELECT
        END IF
      END IF
    END IF
  END IF

  IF (SolFla == -1) THEN
    IF(.NOT. WarmupFlag)THEN
      IF(UnitarySystem(UnitarySysNum)%SensPLRIter .LT. 1)THEN
        UnitarySystem(UnitarySysNum)%SensPLRIter = UnitarySystem(UnitarySysNum)%SensPLRIter+1
        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                                ' - Iteration limit exceeded calculating '// &
                                'part-load ratio for unit = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('Estimated part-load ratio  = '//RoundSigDigits((ReqOutput/FullOutput),3))
        CALL ShowContinueError('Calculated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
        CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation'// &
                                        ' continues. Occurrence info: ')
      ELSE
        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
            //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - Iteration limit exceeded calculating'// &
            ' sensible part-load ratio error continues. Sensible PLR statistics follow.' &
            ,UnitarySystem(UnitarySysNum)%SensPLRIterIndex,PartLoadFrac,PartLoadFrac)
      END IF
    END IF
  ELSEIF (SolFla == -2) THEN
    PartLoadFrac = ReqOutput/FullOutput
    IF(.NOT. WarmupFlag)THEN
      IF(UnitarySystem(UnitarySysNum)%SensPLRFail .LT. 1)THEN
        UnitarySystem(UnitarySysNum)%SensPLRFail = UnitarySystem(UnitarySysNum)%SensPLRFail+1
        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' - sensible part-'// &
                        'load ratio calculation failed: part-load ratio limits exceeded, for unit = '// &
                            TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('Estimated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
        CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation'// &
                                        ' continues. Occurrence info: ')
      ELSE
        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
            //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - sensible part-load ratio calculation'// &
            ' failed error continues. Sensible PLR statistics follow.' &
            ,UnitarySystem(UnitarySysNum)%SensPLRFailIndex,PartLoadFrac,PartLoadFrac)
      END IF
    END IF
  END IF

  IF (SolFlaLat == -1 .AND. SolFla .NE. -1) THEN
    IF(.NOT. WarmupFlag)THEN
      IF(UnitarySystem(UnitarySysNum)%LatPLRIter .LT. 1)THEN
        UnitarySystem(UnitarySysNum)%LatPLRIter = UnitarySystem(UnitarySysNum)%LatPLRIter+1
        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                                ' - Iteration limit exceeded calculating latent part-load'// &
                                ' ratio for unit = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('Estimated part-load ratio   = '//RoundSigDigits((ReqOutput/FullOutput),3))
        CALL ShowContinueError('Calculated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
        CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation'// &
                                        ' continues. Occurrence info: ')
      END IF
        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
            //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - Iteration limit exceeded calculating'// &
            ' latent part-load ratio error continues. Latent PLR statistics follow.' &
            ,UnitarySystem(UnitarySysNum)%LatPLRIterIndex,PartLoadFrac,PartLoadFrac)
    END IF
  ELSEIF (SolFlaLat == -2 .AND. SolFla .NE. -2) THEN
!               RegulaFalsi returns PLR = minPLR when a solution cannot be found, recalculate PartLoadFrac.
    IF(NoLoadHumRatOut-FullLoadHumRatOut .NE. 0.0d0)THEN
        PartLoadFrac = (NoLoadHumRatOut-DesOutHumRat)/(NoLoadHumRatOut-FullLoadHumRatOut)
    ELSE
        PartLoadFrac = 1.0d0
    END IF
    IF(.NOT. WarmupFlag)THEN
      IF(UnitarySystem(UnitarySysNum)%LatPLRFail .LT. 1)THEN
        UnitarySystem(UnitarySysNum)%LatPLRFail = UnitarySystem(UnitarySysNum)%LatPLRFail+1
        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' - latent part-'// &
                        'load ratio calculation failed: part-load ratio limits exceeded, for unit = '//&
                        TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('Estimated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
        CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation'// &
                                        ' continues. Occurrence info: ')
      END IF
        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
            //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - latent part-load ratio calculation'// &
            ' failed error continues. Latent PLR statistics follow.' &
            ,UnitarySystem(UnitarySysNum)%LatPLRFailIndex,PartLoadFrac,PartLoadFrac)
    END IF
  END IF
  !Set the final results

  IF(PartLoadFrac .GT. 1.0d0) THEN
    PartLoadFrac = 1.0d0
  ELSEIF(PartLoadFrac < 0.0d0) THEN
    PartLoadFrac = 0.0d0
  END IF

  UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac = PartLoadFrac
  UnitarySystem(UnitarySysNum)%CoolingSpeedRatio = SpeedRatio
  UnitarySystem(UnitarySysNum)%CoolingCycRatio = CycRatio
  UnitarySystem(UnitarySysNum)%dehumidificationMode = DehumidMode

  LoopDXCoilRTF      = MAX(LoopDXCoilRTF, LoopDXCoilMaxRTFSave)

RETURN
END SUBROUTINE ControlCoolingSystem

SUBROUTINE ControlHeatingSystem(UnitarySysNum, FirstHVACIteration)
          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          !  Simulate the coil object at the required PLR.

          ! METHODOLOGY EMPLOYED:
          !  Calculate operating PLR and adjust speed when using multispeed coils.

          ! REFERENCES:
          !  na

          ! USE STATEMENTS:
  USE Psychrometrics , ONLY: PsyHFnTdbW, PsyTdpFnWPb
  USE General,         ONLY: SolveRegulaFalsi, RoundSigDigits
  USE DXCoils,         ONLY: SimDXCoil, SimDXCoilMultiSpeed, DXCoilOutletTemp, DXCoilOutletHumRat
  USE HeatingCoils,    ONLY: SimulateHeatingCoilComponents
  USE DataAirLoop,     ONLY: LoopHeatingCoilMaxRTF, LoopDXCoilRTF
  USE WaterCoils,      ONLY: SimulateWaterCoilComponents
  USE SteamCoils,      ONLY: SimulateSteamCoilComponents
  USE PlantUtilities,  ONLY: SetComponentFlowRate
  USE WatertoAirHeatPumpSimple,  ONLY: SimWatertoAirHPSimple
  USE WatertoAirHeatPump,        ONLY: SimWaterToAirHP
  USE VariableSpeedCoils,        ONLY: SimVariableSpeedCoils, VarSpeedCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER,  INTENT(In)    :: UnitarySysNum             ! index to Unitary System
  LOGICAL,  INTENT(In)    :: FirstHVACIteration        ! First HVAC iteration flag

          ! SUBROUTINE PARAMETER DEFINITIONS:
  INTEGER, PARAMETER   :: MaxIte    = 500     ! Maximum number of iterations for solver
  REAL(r64), PARAMETER :: Acc       = 1.0d-3   ! Accuracy of solver result
  REAL(r64), PARAMETER :: HumRatAcc = 1.0d-6   ! Accuracy of solver result
  LOGICAL, PARAMETER   :: SuppHeatingCoilFlag = .FALSE.

          ! INTERFACE BLOCK SPECIFICATIONS
          !  na

          ! DERIVED TYPE DEFINITIONS
          !  na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName  ! Name of the heating coil
  INTEGER             :: CompIndex           ! Index to the heating coil
!  REAL(r64)           :: NoOutput            ! Sensible capacity (outlet - inlet) when the compressor is off
  REAL(r64)           :: FullOutput          ! Sensible capacity (outlet - inlet) when the compressor is on
  REAL(r64)           :: ReqOutput           ! Sensible capacity (outlet - inlet) required to meet load or set point temperature
  Integer             :: InletNode           ! Inlet node number of the DX cooling coil
  Integer             :: OutletNode          ! Outlet node number of the DX cooling coil
  Integer             :: ControlNode         ! The node number where a set point is placed to control the DX cooling coil
  REAL(r64)           :: PartLoadFrac        ! The part-load fraction of the compressor

  REAL(r64)           :: SpeedRatio          ! SpeedRatio = (CompressorSpeed - CompressorSpeedMin) /
                                             !              (CompressorSpeedMax - CompressorSpeedMin)
                                             ! for variable speed or 2 speed compressors
  INTEGER             :: SpeedNum
  REAL(r64)           :: CycRatio            ! Cycling part-load ratio for variable speed or 2 speed compressors
  REAL(r64)           :: DesOutTemp          ! Desired outlet temperature of the DX cooling coil

  INTEGER             :: SolFla              ! Flag of solver, num iterations if >0, else error index
  REAL(r64), DIMENSION(8)  :: Par                 ! Parameter array passed to solver
  LOGICAL             :: SensibleLoad        ! True if there is a sensible cooling load on this system
  LOGICAL             :: LatentLoad          ! True if there is a latent   cooling load on this system
  INTEGER             :: FanOpMode           ! Supply air fan operating mode
  REAL(R64)           :: LoopHeatingCoilMaxRTFSave ! Used to find RTF of heating coils without overwriting globabl variable
  REAL(R64)           :: LoopDXCoilMaxRTFSave ! Used to find RTF of DX heating coils without overwriting globabl variable
  REAL(r64)           :: dummy               ! dummy variable for heating latent demand
  REAL(r64)           :: WSHPRuntimeFrac            ! Run time fraction of water to air hp
  REAL(R64)           :: OutdoorDryBulb     ! local variable for OutDryBulbTemp
  REAL(R64)           :: OutdoorHumRat      ! local variable for OutHumRat
  REAL(R64)           :: OutdoorPressure    ! local variable for OutBaroPress
  REAL(R64)           :: OutdoorWetBulb     ! local variable for OutWetBulbTemp
  REAL(R64)           :: OutletTemp

      ! Set local variables
      ! Retrieve the load on the controlled zone
  InletNode    = UnitarySystem(UnitarySysNum)%HeatCoilInletNodeNum
  OutletNode   = UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum
  ControlNode  = UnitarySystem(UnitarySysNum)%SystemHeatControlNodeNum
  DesOutTemp   = UnitarySystem(UnitarySysNum)%DesiredOutletTemp
  LoopHeatingCoilMaxRTFSave=LoopHeatingCoilMaxRTF
  LoopHeatingCoilMaxRTF = 0.0d0
  LoopDXCoilMaxRTFSave=LoopDXCoilRTF
  LoopDXCoilRTF=0.0d0

  CompName     = UnitarySystem(UnitarySysNum)%HeatingCoilName
  CompIndex    = UnitarySystem(UnitarySysNum)%HeatingCoilIndex
  FanOpMode    = UnitarySystem(UnitarySysNum)%FanOpMode

  PartLoadFrac = 0.0d0
  SpeedRatio   = 0.0d0
  CycRatio     = 0.0d0
  Dummy        = 0.0d0
  SolFla       = 0.0d0
  SensibleLoad = .FALSE.
  LatentLoad   = .FALSE.

  IF (UnitarySystem(UnitarySysNum)%CondenserNodeNum /= 0) THEN
    OutdoorDryBulb  = Node(UnitarySystem(UnitarySysNum)%CondenserNodeNum)%Temp
    IF(UnitarySystem(UnitarySysNum)%CondenserType == WaterCooled)THEN
      OutdoorHumRat   = OutHumRat
      OutdoorPressure = OutBaroPress
      OutdoorWetBulb  = OutWetBulbTemp
    ELSE
      OutdoorPressure = Node(UnitarySystem(UnitarySysNum)%CondenserNodeNum)%Press
      ! IF node is not connected to anything, pressure = default, use weather data
      IF(OutdoorPressure == DefaultNodeValues%Press)THEN
        OutdoorDryBulb  = OutDryBulbTemp
        OutdoorHumRat   = OutHumRat
        OutdoorPressure = OutBaroPress
        OutdoorWetBulb  = OutWetBulbTemp
      ELSE
        OutdoorHumRat   = Node(UnitarySystem(UnitarySysNum)%CondenserNodeNum)%HumRat
  !     this should use Node%WetBulbTemp or a PSYC function, not OAWB
        OutdoorWetBulb  = Node(UnitarySystem(UnitarySysNum)%CondenserNodeNum)%OutAirWetBulb
      END IF
    END IF
  ELSE
    OutdoorDryBulb  = OutDryBulbTemp
    OutdoorHumRat   = OutHumRat
    OutdoorPressure = OutBaroPress
    OutdoorWetBulb  = OutWetBulbTemp
  END IF

  ! IF DXHeatingSystem is scheduled on and there is flow
  IF(GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%SysAvailSchedPtr) > 0.0d0 .AND. &
      GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%HeatingCoilAvailSchPtr) > 0.0d0 .AND. &
      Node(InletNode)%MassFlowRate .gt. MinAirMassFlow .AND. UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac == 0.0d0) THEN

    ! Determine if there is a sensible load on this system
!    IF((Node(InletNode)%Temp < Node(ControlNode)%TempSetPoint) .AND. &
    IF((Node(InletNode)%Temp < DesOutTemp) .AND. &
       (ABS(Node(InletNode)%Temp - DesOutTemp) .gt. TempControlTol) ) SensibleLoad = .TRUE.


    ! IF DXHeatingSystem runs with a heating load then set PartLoadFrac on Heating System
    IF (SensibleLoad ) THEN

      ReqOutput = Node(InletNode)%MassFlowRate *  &
                      (PsyHFnTdbW(UnitarySystem(UnitarySysNum)%DesiredOutletTemp,Node(InletNode)%HumRat) - &
                       PsyHFnTdbW(Node(InletNode)%Temp,Node(InletNode)%HumRat))

      ! Get no load result
      PartLoadFrac = 0.0d0
      WSHPRuntimeFrac = 0.0d0

      SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)

        CASE (CoilDX_HeatingEmpirical)  ! Coil:Heating:DX:SingleSpeed

          CALL SimDXCoil(CompName,On,FirstHVACIteration,PartLoadFrac,UnitarySystem(UnitarySysNum)%HeatingCoilIndex,FanOpMode)
          UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

        CASE (CoilDX_MultiSpeedHeating, Coil_HeatingAirToAirVariableSpeed, Coil_HeatingWaterToAirHPVSEquationFit, &
              Coil_HeatingElectric_MultiStage, Coil_HeatingGas_MultiStage)

          CALL SimMultiSpeedCoils(UnitarySysNum, FirstHVACIteration, SensibleLoad, LatentLoad, PartLoadFrac, &
                                  HeatingCoil)

        CASE (Coil_HeatingGas,Coil_HeatingElectric,Coil_HeatingDesuperheater )

          CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=CompIndex, &
                                FanOpMode=FanOpMode, QCoilReq = 0.0d0)

        CASE (Coil_HeatingWater)

          CALL SimWaterCoils(UnitarySysNum, FirstHVACIteration, PartLoadFrac, HeatingCoil)

        CASE (Coil_HeatingSteam)

          CALL SimSteamCoils(UnitarySysNum, FirstHVACIteration, PartLoadFrac, HeatingCoil)
          IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow .GT. 0.0d0)PartLoadFrac = &
                     MIN(1.0d0,Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum)%MassFlowRate/ &
                              UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow)

        CASE(Coil_HeatingWaterToAirHPSimple)

          CALL SimWatertoAirHPSimple(Blank, UnitarySystem(UnitarySysNum)%HeatingCoilIndex, ReqOutput, Dummy, &
                                     FanOpMode,WSHPRuntimeFrac, UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                     UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                     0, PartLoadFrac, FirstHVACIteration)
          UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

        CASE(Coil_HeatingWaterToAirHP)

          CALL SimWatertoAirHP(Blank, UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                 UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow,FanOpMode, &
                                 FirstHVACIteration,WSHPRuntimeFrac,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                 UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                 UnitarySystem(UnitarySysNum)%InitHeatPump, ReqOutput,Dummy,0, PartLoadFrac)
          UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

        CASE DEFAULT

      END SELECT

!     IF outlet temp at no load is within ACC of set point, do not run the coil
      IF(ABS(Node(OutletNode)%Temp-DesOutTemp) < Acc)THEN
       ! do nothing, coil is at the set point.
      ELSE IF ((Node(OutletNode)%Temp-DesOutTemp) > Acc) THEN ! IF outlet temp is above set point turn off coil
        PartLoadFrac = 0.0d0
      ELSE ! ELSE get full load result

        ! Get full load result
        PartLoadFrac = 1.0d0
        WSHPRuntimeFrac = 1.0d0

        SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)

          CASE (CoilDX_HeatingEmpirical)  ! Coil:Heating:DX:SingleSpeed

            CALL SimDXCoil(CompName,On,FirstHVACIteration,PartLoadFrac,UnitarySystem(UnitarySysNum)%HeatingCoilIndex,FanOpMode)
            UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

          CASE (CoilDX_MultiSpeedHeating, Coil_HeatingAirToAirVariableSpeed, Coil_HeatingWaterToAirHPVSEquationFit, &
                Coil_HeatingElectric_MultiStage, Coil_HeatingGas_MultiStage)

            CycRatio = 1.0d0
            DO SpeedNum = 1, UnitarySystem(UnitarySysNum)%NumOfSpeedHeating
              CALL SimMultiSpeedCoils(UnitarySysNum, FirstHVACIteration, SensibleLoad, LatentLoad, PartLoadFrac, &
                                      HeatingCoil, SpeedNum)
              OutletTemp = Node(OutletNode)%Temp
              SpeedRatio = REAL(SpeedNum,r64) - 1.0d0
              IF (OutletTemp > DesOutTemp .AND. SensibleLoad) EXIT
            END DO

          CASE (Coil_HeatingGas,Coil_HeatingElectric)

            CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=CompIndex, &
                                FanOpMode=FanOpMode, QCoilReq = UnitarySystem(UnitarySysNum)%DesignHeatingCapacity)

          CASE (Coil_HeatingDesuperheater )

              CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=CompIndex, &
                                FanOpMode=FanOpMode, QCoilReq = ReqOutput)

          CASE (Coil_HeatingWater)

            CALL SimWaterCoils(UnitarySysNum, FirstHVACIteration, PartLoadFrac, HeatingCoil)

          CASE (Coil_HeatingSteam)

            CALL SimSteamCoils(UnitarySysNum, FirstHVACIteration, PartLoadFrac, HeatingCoil)
            IF(UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow .GT. 0.0d0)PartLoadFrac = &
                     MIN(1.0d0,Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum)%MassFlowRate/ &
                              UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow)


          CASE(Coil_HeatingWaterToAirHPSimple)

            CALL SimWatertoAirHPSimple(Blank, UnitarySystem(UnitarySysNum)%HeatingCoilIndex, ReqOutput, Dummy, &
                                     FanOpMode,WSHPRuntimeFrac, UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                     UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                     0, PartLoadFrac, FirstHVACIteration)
            UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

          CASE(Coil_HeatingWaterToAirHP)
            CALL SimWatertoAirHP(Blank, UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                 UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow,FanOpMode, &
                                 FirstHVACIteration,WSHPRuntimeFrac,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                                 UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                                 UnitarySystem(UnitarySysNum)%InitHeatPump, ReqOutput,Dummy,0, PartLoadFrac)
            UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac


          CASE DEFAULT

        END SELECT

        FullOutput = Node(InletNode)%MassFlowRate *  &
                       (PsyHFnTdbW(Node(OutletNode)%Temp,Node(InletNode)%HumRat)  &
                        - PsyHFnTdbW(Node(InletNode)%Temp,Node(InletNode)%HumRat))

!       If the outlet temp is within ACC of set point,
        IF(ABS(Node(OutletNode)%Temp-DesOutTemp) < Acc)THEN
          ! do nothing, coil is at set point
        ELSE IF (Node(OutletNode)%Temp .LT. (DesOutTemp-Acc)) THEN ! IF outlet temp is below set point coil must be on
          PartLoadFrac = 1.0d0
        ELSE  ! ELSE find the PLR to meet the set point

          SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)

            CASE (CoilDX_HeatingEmpirical)  ! Coil:Heating:DX:SingleSpeed

              Par(1) = REAL(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,r64)
              Par(2) = DesOutTemp
              Par(3) = 1.0d0  !OnOffAirFlowFrac assume = 1.0 for continuous fan dx system
              Par(5) = REAL(FanOpMode,r64) ! this does nothing since set point based control requires constant fan
              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, DXHeatingCoilResidual, 0.0d0,   &
                                            1.0d0, Par)
              UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadFrac

            CASE (CoilDX_MultiSpeedHeating, Coil_HeatingAirToAirVariableSpeed, Coil_HeatingWaterToAirHPVSEquationFit, &
                  Coil_HeatingElectric_MultiStage, Coil_HeatingGas_MultiStage)

              Par(1) = REAL(UnitarySystem(UnitarySysNum)%HeatingCoilIndex,r64)
              Par(2) = DesOutTemp
              Par(3) = UnitarySysNum
              ! Par(4) = CycRatio or SpeedRatio
              Par(5) = UnitarySystem(UnitarySysNum)%HeatingSpeedNum
              Par(6) = 1.0d0 ! UnitarySystem(UnitarySysNum)%FanOpMode
              Par(7) = 1.0d0 ! UnitarySystem(UnitarySysNum)%CompOp
              Par(8) = ReqOutput ! UnitarySystem(UnitarySysNum)%FanOpMode
              IF (SpeedRatio == 1.0d0) THEN
                Par(4) = CycRatio
                CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, SpeedRatio, HeatingCoilVarSpeedResidual, 0.0d0,   &
                                                1.0d0, Par)
                UnitarySystem(UnitarySysNum)%HeatingCycRatio = CycRatio
                UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = SpeedRatio
                UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac = SpeedRatio
                CALL CalcPassiveSystem(UnitarySysNum, FirstHVACIteration)
                PartLoadFrac = SpeedRatio
              ELSE
                SpeedRatio = 0.0d0
                UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = SpeedRatio
                Par(4) = SpeedRatio
                CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, CycRatio, HeatingCoilVarSpeedCycResidual, 0.0d0,   &
                                                1.0d0, Par)
                UnitarySystem(UnitarySysNum)%HeatingCycRatio = CycRatio
                UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac = CycRatio
                CALL CalcPassiveSystem(UnitarySysNum, FirstHVACIteration)
                PartLoadFrac = CycRatio
              END IF

            CASE (Coil_HeatingGas,Coil_HeatingElectric, Coil_HeatingDesuperheater)

              Par(1) = REAL(UnitarySysNum,r64)
              IF (FirstHVACIteration) THEN
                Par(2) = 1.0d0
              ELSE
                Par(2) = 0.0d0
              END IF
              Par(3) = DesOutTemp
              IF (SuppHeatingCoilFlag) THEN
                Par(4) = 1.0d0
              ELSE
                Par(4) = 0.0d0
              END IF
              Par(5) = FanOpMode
              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, GasElecHeatingCoilResidual, 0.0d0,   &
                                                1.0d0, Par)

            CASE (Coil_HeatingWater)

              Par(1) = REAL(UnitarySysNum,r64)
              IF (FirstHVACIteration) THEN
                Par(2) = 1.0d0
              ELSE
                Par(2) = 0.0d0
              END IF
              Par(3) = DesOutTemp
              IF (SuppHeatingCoilFlag) THEN
                Par(4) = 1.0d0
              ELSE
                Par(4) = 0.0d0
              END IF
              Par(5) = 0.0d0
              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, HotWaterHeatingCoilResidual, 0.0d0,   &
                                                1.0d0, Par)

            CASE (Coil_HeatingSteam)

              Par(1) = REAL(UnitarySysNum,r64)
              IF (FirstHVACIteration) THEN
                Par(2) = 1.0d0
              ELSE
                Par(2) = 0.0d0
              END IF
              Par(3) = DesOutTemp
              IF (SuppHeatingCoilFlag) THEN
                Par(4) = 1.0d0
              ELSE
                Par(4) = 0.0d0
              END IF

              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, SteamHeatingCoilResidual, 0.0d0,   &
                                                1.0d0, Par)

            CASE(Coil_HeatingWaterToAirHPSimple, Coil_HeatingWaterToAirHP)

              Par(1) = REAL(UnitarySysNum,r64)
              IF (FirstHVACIteration) THEN
                Par(2) = 1.0d0
              ELSE
                Par(2) = 0.0d0
              END IF
              Par(3) = DesOutTemp
              Par(4) = ReqOutput

              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, HeatWatertoAirHPTempResidual, 0.0d0,   &
                                            1.0d0, Par)

            CASE DEFAULT
              CALL ShowMessage(' For :'//TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//'="'// &
                                       TRIM(UnitarySystem(UnitarySysNum)%Name)//'"')
              CALL ShowFatalError('ControlHeatingSystem: Invalid heating coil type = '//  &
                                  TRIM(CALLCoilTypes(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)))

          END SELECT
        END IF
      END IF
    END IF
  END IF

  IF(PartLoadFrac .GT. 1.0d0) THEN
    PartLoadFrac = 1.0d0
  ELSEIF(PartLoadFrac < 0.0d0) THEN
    PartLoadFrac = 0.0d0
  END IF

  IF (SolFla == -1) THEN
    IF(.NOT. WarmupFlag)THEN
      IF(UnitarySystem(UnitarySysNum)%HeatCoilSensPLRIter .LT. 1)THEN
        UnitarySystem(UnitarySysNum)%HeatCoilSensPLRIter = UnitarySystem(UnitarySysNum)%HeatCoilSensPLRIter+1
        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                                ' - Iteration limit exceeded calculating sensible '// &
                                'part-load ratio for unit = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('Estimated part-load ratio  = '//RoundSigDigits((ReqOutput/FullOutput),3))
        CALL ShowContinueError('Calculated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
        CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation'// &
                                        ' continues. Occurrence info: ')
      ELSE
        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
            //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - Iteration limit exceeded calculating'// &
            ' sensible part-load ratio error continues. Sensible PLR statistics follow.' &
            ,UnitarySystem(UnitarySysNum)%HeatCoilSensPLRIterIndex,PartLoadFrac,PartLoadFrac)
      END IF
    END IF
  ELSEIF (SolFla == -2) THEN
    PartLoadFrac = ReqOutput/FullOutput
    IF(.NOT. WarmupFlag)THEN
      IF(UnitarySystem(UnitarySysNum)%HeatCoilSensPLRFail .LT. 1)THEN
        UnitarySystem(UnitarySysNum)%HeatCoilSensPLRFail = UnitarySystem(UnitarySysNum)%HeatCoilSensPLRFail+1
        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' - sensible part-'// &
                        'load ratio calculation failed: part-load ratio limits exceeded, for unit = '// &
                            TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('Estimated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
        CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation'// &
                                        ' continues. Occurrence info: ')
      ELSE
        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
            //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - sensible part-load ratio calculation'// &
            ' failed error continues. Sensible PLR statistics follow.' &
            ,UnitarySystem(UnitarySysNum)%HeatCoilSensPLRFailIndex,PartLoadFrac,PartLoadFrac)
      END IF
    END IF
  END IF

  !Set the final results
  UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac = PartLoadFrac
  UnitarySystem(UnitarySysNum)%HeatingSpeedRatio = SpeedRatio
  UnitarySystem(UnitarySysNum)%HeatingCycRatio = CycRatio

  LoopHeatingCoilMaxRTF = MAX(LoopHeatingCoilMaxRTF, LoopHeatingCoilMaxRTFSave)
  LoopDXCoilRTF      = MAX(LoopDXCoilRTF, LoopDXCoilMaxRTFSave)

RETURN
END SUBROUTINE ControlHeatingSystem

SUBROUTINE ControlSuppHeatSystem(UnitarySysNum, FirstHVACIteration )
          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          !  This subroutine updates the System outlet nodes.

          ! METHODOLOGY EMPLOYED:
          !  Data is moved from the System data structure to the System outlet nodes.

          ! REFERENCES:
          !  na

          ! USE STATEMENTS:
  USE DataAirLoop,     ONLY: LoopHeatingCoilMaxRTF, LoopDXCoilRTF
  USE Psychrometrics,  ONLY: PsyHFnTdbW, PsyTdpFnWPb
  USE General,         ONLY: SolveRegulaFalsi, RoundSigDigits
  USE HeatingCoils,    ONLY: SimulateHeatingCoilComponents
  USE WaterCoils,      ONLY: SimulateWaterCoilComponents
  USE SteamCoils,      ONLY: SimulateSteamCoilComponents
  USE PlantUtilities,  ONLY: SetComponentFlowRate


  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER,  INTENT(In)    :: UnitarySysNum           ! index to Unitary System
  LOGICAL,  INTENT(In)    :: FirstHVACIteration      ! First HVAC iteration flag

          ! SUBROUTINE PARAMETER DEFINITIONS:
  INTEGER, PARAMETER   :: MaxIte    = 500     ! Maximum number of iterations for solver
  REAL(r64), PARAMETER :: Acc       = 1.0d-3  ! Accuracy of solver result
  REAL(r64), PARAMETER :: HumRatAcc = 1.0d-6  ! Accuracy of solver result
  INTEGER, PARAMETER   :: SolveMaxIter=50

          ! INTERFACE BLOCK SPECIFICATIONS
          !  na

          ! DERIVED TYPE DEFINITIONS
          !  na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName  ! Name of the heating coil
  INTEGER             :: CompIndex           ! Index to the heating coil
!  REAL(r64)           :: NoOutput            ! Sensible capacity (outlet - inlet) when the compressor is off
  REAL(r64)           :: FullOutput          ! Sensible capacity (outlet - inlet) when the compressor is on
  REAL(r64)           :: ReqOutput           ! Sensible capacity (outlet - inlet) required to meet load or set point temperature
  Integer             :: InletNode           ! Inlet node number of the DX cooling coil
  Integer             :: OutletNode          ! Outlet node number of the DX cooling coil
  Integer             :: ControlNode         ! The node number where a set point is placed to control the DX cooling coil
  REAL(r64)           :: PartLoadFrac        ! The part-load fraction of the compressor

  REAL(r64)           :: DesOutTemp          ! Desired outlet temperature of the DX cooling coil
  REAL(r64)           :: QCoilActual         ! Heating coil operating capacity [W]

  INTEGER             :: SolFla              ! Flag of solver, num iterations if >0, else error index
  REAL(r64), DIMENSION(5)  :: Par            ! Parameter array passed to solver
  LOGICAL             :: SensibleLoad        ! True if there is a sensible cooling load on this system
  INTEGER             :: FanOpMode           ! Supply air fan operating mode
  REAL(R64)           :: LoopHeatingCoilMaxRTFSave ! Used to find RTF of heating coils without overwriting globabl variable
  REAL(R64)           :: LoopDXCoilMaxRTFSave ! Used to find RTF of DX heating coils without overwriting globabl variable
  LOGICAL             :: SuppHeatingCoilFlag = .TRUE.
  REAL(r64)           :: NoLoadTempOut       ! save outlet temp when coil is off (C)

      ! Set local variables
      ! Retrieve the load on the controlled zone

  OutletNode   = UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode
  InletNode    = UnitarySystem(UnitarySysNum)%SuppCoilAirInletNode
  ControlNode  = UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode
  DesOutTemp   = UnitarySystem(UnitarySysNum)%DesiredOutletTemp
  CompName     = UnitarySystem(UnitarySysNum)%SuppHeatCoilName
  CompIndex    = UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex
  FanOpMode    = UnitarySystem(UnitarySysNum)%FanOpMode
  SolFla       = 0.0d0

  PartLoadFrac = 0.0d0

  SensibleLoad = .FALSE.

  LoopHeatingCoilMaxRTFSave=LoopHeatingCoilMaxRTF
  LoopHeatingCoilMaxRTF = 0.0d0
  LoopDXCoilMaxRTFSave=LoopDXCoilRTF
  LoopDXCoilRTF=0.0d0

  IF((GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%SysAvailSchedPtr) > 0.0d0) .AND. &
     (Node(InletNode)%MassFlowRate .gt. MinAirMassFlow)) THEN

    ! Determine if there is a sensible load on this system
    IF((Node(InletNode)%Temp < DesOutTemp) .AND. &
       (ABS(Node(InletNode)%Temp - DesOutTemp) .gt. TempControlTol) ) SensibleLoad = .TRUE.

    IF (SensibleLoad ) THEN

      ReqOutput = Node(InletNode)%MassFlowRate *  &
                       (PsyHFnTdbW(UnitarySystem(UnitarySysNum)%DesiredOutletTemp,Node(InletNode)%HumRat) - &
                        PsyHFnTdbW(Node(InletNode)%Temp,Node(InletNode)%HumRat))

      ! Get no load result
      PartLoadFrac = 0.0d0

      SELECT CASE(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num)

        CASE (Coil_HeatingGas,Coil_HeatingElectric,Coil_HeatingDesuperheater )
          CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                CompIndex=CompIndex, PartLoadRatio = PartLoadFrac, & ! QCoilReq= 0.0d0,  &
                                SuppHeat=SuppHeatingCoilFlag,FanOpMode=FanOpMode,QCoilActual=QCoilActual)
          PartLoadFrac=QCoilActual/UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity

        CASE (Coil_HeatingWater)

          CALL SimWaterCoils(UnitarySysNum, FirstHVACIteration, PartLoadFrac, SuppHeatCoil)

        CASE (Coil_HeatingSteam)

          CALL SimSteamCoils(UnitarySysNum, FirstHVACIteration, PartLoadFrac, SuppHeatCoil)

        CASE DEFAULT

      END SELECT


      NoLoadTempOut = Node(OutletNode)%Temp
!      NoOutput = Node(InletNode)%MassFlowRate *  &
!                       (PsyHFnTdbW(NoLoadTempOut,Node(OutletNode)%HumRat)  &
!                        - PsyHFnTdbW(Node(InletNode)%Temp,Node(OutletNode)%HumRat))

!     If OutletTemp is within ACC of set point, either coil operated or is not needed
      IF(ABS(Node(OutletNode)%Temp-DesOutTemp) < Acc)THEN
        ! do nothing, coil is at set point (i.e., gas/elec/steam coil will try to hit set point
      ELSE IF(PartLoadFrac .GT. 0.0d0)THEN
        ! do nothing, coil tried to hit set point (i.e., gas/elec/steam coil tried to hit set point but missed
      ELSE IF (NoLoadTempOut .GT. (DesOutTemp - Acc)) THEN
        PartLoadFrac = 0.0d0 ! outlet temp > set point, coil is not needed
      ELSE ! outlet temp too low, turn on coil

        ! Get full load result
        PartLoadFrac = 1.0d0

        SELECT CASE(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num)

          CASE (Coil_HeatingGas,Coil_HeatingElectric)

            CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
!                                  CompIndex=CompIndex, QCoilReq= UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity,  &
                                  CompIndex=CompIndex, PartLoadRatio = PartLoadFrac, &
                                  SuppHeat=SuppHeatingCoilFlag, FanOpMode=FanOpMode,QCoilActual=QCoilActual)
            PartLoadFrac=QCoilActual/UnitarySystem(UnitarySysNum)%DesignSuppHeatingCapacity

          CASE (Coil_HeatingDesuperheater )

            CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                  CompIndex=CompIndex, QCoilReq= ReqOutput,  &
                                  SuppHeat=SuppHeatingCoilFlag, FanOpMode=FanOpMode)

          CASE (Coil_HeatingWater)

            CALL SimWaterCoils(UnitarySysNum, FirstHVACIteration, PartLoadFrac, SuppHeatCoil)

          CASE (Coil_HeatingSteam)

            CALL SimSteamCoils(UnitarySysNum, FirstHVACIteration, PartLoadFrac, SuppHeatCoil)

          CASE DEFAULT

        END SELECT

        FullOutput = Node(InletNode)%MassFlowRate *  &
                       (PsyHFnTdbW(Node(OutletNode)%Temp,Node(InletNode)%HumRat)  &
                        - PsyHFnTdbW(Node(InletNode)%Temp,Node(InletNode)%HumRat))

!         If the FullOutput outlet temp is less than (insufficient heating) or very near set point,
!         run the coil at PartLoadFrac = 1.
        IF (Node(OutletNode)%Temp .LT. (DesOutTemp+Acc)) THEN
          PartLoadFrac = 1.0d0
        ELSE

          SELECT CASE(UnitarySystem(UnitarySysNum)%SuppHeatCoilType_Num)

            CASE (Coil_HeatingGas,Coil_HeatingElectric, Coil_HeatingDesuperheater)

              Par(1) = REAL(UnitarySysNum,r64)
              IF (FirstHVACIteration) THEN
                Par(2) = 1.0d0
              ELSE
                Par(2) = 0.0d0
              END IF
              Par(3) = DesOutTemp
              IF (SuppHeatingCoilFlag) THEN
                Par(4) = 1.0d0
              ELSE
                Par(4) = 0.0d0
              END IF
              Par(5) = FanOpMode
              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, GasElecHeatingCoilResidual, 0.0d0,   &
                                                1.0d0, Par)

            CASE (Coil_HeatingWater)

               Par(1) = REAL(UnitarySysNum,r64)
               IF (FirstHVACIteration) THEN
                 Par(2) = 1.0d0
               ELSE
                 Par(2) = 0.0d0
               END IF
               Par(3) = DesOutTemp
               IF (SuppHeatingCoilFlag) THEN
                 Par(4) = 1.0d0
               ELSE
                 Par(4) = 0.0d0
               END IF
               Par(5)=0.0d0
               CALL SolveRegulaFalsi(Acc, SolveMaxIter, SolFla, PartLoadFrac, HotWaterHeatingCoilResidual, &
                                     0.0d0, 1.0d0, Par)

            CASE (Coil_HeatingSteam)

              Par(1) = REAL(UnitarySysNum,r64)
              IF (FirstHVACIteration) THEN
                Par(2) = 1.0d0
              ELSE
                Par(2) = 0.0d0
              END IF
              Par(3) = DesOutTemp
              IF (SuppHeatingCoilFlag) THEN
                Par(4) = 1.0d0
              ELSE
                Par(4) = 0.0d0
              END IF

              CALL SolveRegulaFalsi(Acc, MaxIte, SolFla, PartLoadFrac, SteamHeatingCoilResidual, 0.0d0,   &
                                                1.0d0, Par)

            CASE DEFAULT

          END SELECT

        END IF   ! IF ((FullOutput - ReqOutput) < Acc) THEN
      END IF     ! IF ((NoOutput-ReqOutput) > Acc) THEN
    END IF       ! IF (SensibleLoad ) THEN
  END IF         ! IF((GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%SysAvailSchedPtr) > 0.0d0) .AND. &

  IF(PartLoadFrac .GT. 1.0d0) THEN
    PartLoadFrac = 1.0d0
  ELSEIF(PartLoadFrac < 0.0d0) THEN
    PartLoadFrac = 0.0d0
  END IF

  IF (SolFla == -1) THEN
    IF(.NOT. WarmupFlag)THEN
      IF(UnitarySystem(UnitarySysNum)%SuppHeatCoilSensPLRIter .LT. 1)THEN
        UnitarySystem(UnitarySysNum)%SuppHeatCoilSensPLRIter = UnitarySystem(UnitarySysNum)%SuppHeatCoilSensPLRIter+1
        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)// &
                              ' - Iteration limit exceeded calculating sensible '// &
                              'part-load ratio for unit = '//TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('Estimated part-load ratio  = '//RoundSigDigits((ReqOutput/FullOutput),3))
        CALL ShowContinueError('Calculated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
        CALL ShowContinueErrorTimeStamp('The calculated part-load ratio will be used and the simulation'// &
                                      ' continues. Occurrence info: ')
      ELSE
        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
        //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - Iteration limit exceeded calculating'// &
        ' sensible part-load ratio error continues. Sensible PLR statistics follow.' &
        ,UnitarySystem(UnitarySysNum)%SuppHeatCoilSensPLRIterIndex,PartLoadFrac,PartLoadFrac)
      END IF
    END IF  ! IF(.NOT. WarmupFlag)THEN
  ELSEIF (SolFla == -2) THEN
    PartLoadFrac = ReqOutput/FullOutput
    IF(.NOT. WarmupFlag)THEN
      IF(UnitarySystem(UnitarySysNum)%SuppHeatCoilSensPLRFail .LT. 1)THEN
        UnitarySystem(UnitarySysNum)%SuppHeatCoilSensPLRFail = UnitarySystem(UnitarySysNum)%SuppHeatCoilSensPLRFail+1
        CALL ShowWarningError(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' - sensible part-'// &
                              'load ratio calculation failed: part-load ratio limits exceeded, for unit = '// &
                              TRIM(UnitarySystem(UnitarySysNum)%Name))
        CALL ShowContinueError('Estimated part-load ratio = '//RoundSigDigits(PartLoadFrac,3))
        CALL ShowContinueErrorTimeStamp('The estimated part-load ratio will be used and the simulation'// &
                                        ' continues. Occurrence info: ')
      ELSE
        CALL ShowRecurringWarningErrorAtEnd(TRIM(UnitarySystem(UnitarySysNum)%UnitarySystemType)//' "'&
             //TRIM(UnitarySystem(UnitarySysNum)%Name)//'" - sensible part-load ratio calculation'// &
             ' failed error continues. Sensible PLR statistics follow.' &
             ,UnitarySystem(UnitarySysNum)%SuppHeatCoilSensPLRFailIndex,PartLoadFrac,PartLoadFrac)
      END IF
    END IF  ! IF(.NOT. WarmupFlag)THEN
  END IF  ! IF (SolFla == -1) THEN

  UnitarySystem(UnitarySysNum)%SuppHeatPartLoadFrac = PartLoadFrac

  LoopHeatingCoilMaxRTF = MAX(LoopHeatingCoilMaxRTF, LoopHeatingCoilMaxRTFSave)
  LoopDXCoilRTF      = MAX(LoopDXCoilRTF, LoopDXCoilMaxRTFSave)

RETURN
END SUBROUTINE ControlSuppHeatSystem

SUBROUTINE SimWaterCoils(UnitarySysNum, FirstHVACIteration,PartLoadFrac, CoilType)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Chandan Sharma, FSEC
          !       DATE WRITTEN   March 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine manages water cooling/heating coil simulation.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE WaterCoils,       ONLY: SimulateWaterCoilComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)          :: UnitarySysNum    ! Index of AirloopHVAC:UnitarySystem object
  INTEGER, INTENT(IN)          :: CoilType
  LOGICAL, INTENT(IN)          :: FirstHVACIteration  ! True when first HVAC iteration
  REAL(R64), INTENT(IN)        :: PartLoadFrac
          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName              ! Name of Unitary System object
  REAL(R64)                     :: mdot

 IF (CoilType == CoolingCoil) THEN
    CompName     = UnitarySystem(UnitarySysNum)%CoolingCoilName

    mdot = MIN(Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
           UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow * PartLoadFrac)
    Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode)%MassFlowRate = mdot

    CALL SimulateWaterCoilComponents(CompName,FirstHVACIteration,UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                    FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode, &
                                    PartLoadRatio = PartLoadFrac)

 ELSEIF (CoilType == HeatingCoil) THEN
    CompName     = UnitarySystem(UnitarySysNum)%HeatingCoilName

    mdot = MIN(Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
           UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow * PartLoadFrac)
    Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode)%MassFlowRate = mdot

    CALL SimulateWaterCoilComponents(CompName,FirstHVACIteration,UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                    FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode, &
                                    PartLoadRatio = PartLoadFrac)

 ELSE
    CompName     = UnitarySystem(UnitarySysNum)%SuppHeatCoilName

    mdot = MIN(Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
           UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow * PartLoadFrac)
    Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode)%MassFlowRate = mdot

    CALL SimulateWaterCoilComponents(CompName,FirstHVACIteration,UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
                                    FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode, &
                                    PartLoadRatio = PartLoadFrac)
 END IF

END SUBROUTINE SimWaterCoils

SUBROUTINE SimSteamCoils(UnitarySysNum, FirstHVACIteration,PartLoadFrac, CoilType)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Chandan Sharma, FSEC
          !       DATE WRITTEN   March 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine manages steam heating coil simulation.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE SteamCoils,       ONLY: SimulateSteamCoilComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)          :: UnitarySysNum    ! Index of AirloopHVAC:UnitarySystem object
  INTEGER, INTENT(IN)          :: CoilType
  LOGICAL, INTENT(IN)          :: FirstHVACIteration  ! True when first HVAC iteration
  REAL(R64), INTENT(IN)        :: PartLoadFrac
          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName              ! Name of Unitary System object
  REAL(R64)                     :: mdot

  IF (CoilType == HeatingCoil) THEN

    CompName     = UnitarySystem(UnitarySysNum)%HeatingCoilName

    mdot = MIN(Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
           UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow * PartLoadFrac)
    Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode)%MassFlowRate = mdot

    CALL SimulateSteamCoilComponents(CompName, FirstHVACIteration, &
                                           1.0d0, & !QCoilReq, simulate any load > 0 to get max capacity
                                           UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                           FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode, &
                                           PartLoadRatio = PartLoadFrac)

  ELSE

    CompName     = UnitarySystem(UnitarySysNum)%SuppHeatCoilName

    mdot = MIN(Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
           UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow * PartLoadFrac)
    Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode)%MassFlowRate = mdot

    CALL SimulateSteamCoilComponents(CompName, FirstHVACIteration, &
                                           1.0d0, & !QCoilReq, simulate any load > 0 to get max capacity
                                           UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
                                           FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode, &
                                           PartLoadRatio = PartLoadFrac)

  END IF
RETURN

END SUBROUTINE SimSteamCoils

SUBROUTINE SimMultiSpeedCoils(UnitarySysNum, FirstHVACIteration, SensibleLoad, LatentLoad, PartLoadFrac, CoilType, SpeedNumber)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Chandan Sharma, FSEC
          !       DATE WRITTEN   March 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine manages multispeed and variable speed cooling coil simulation.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DXCoils,            ONLY: SimDXCoilMultiSpeed, DXCoilOutletTemp
  USE VariableSpeedCoils, ONLY: SimVariableSpeedCoils
  USE HeatingCoils,       ONLY: SimulateHeatingCoilComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)           :: UnitarySysNum    ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL, INTENT(IN)           :: FirstHVACIteration  ! True when first HVAC iteration
  LOGICAL, INTENT(IN)           :: SensibleLoad
  LOGICAL, INTENT(IN)           :: LatentLoad
  INTEGER, INTENT(IN)           :: CoilType
  REAL(R64), INTENT(IN)         :: PartLoadFrac
  INTEGER, OPTIONAL,INTENT(IN)  :: SpeedNumber

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  CHARACTER(len=MaxNameLength)  :: CompName              ! Name of Unitary System object
  REAL(R64)                     :: Dummy
  REAL(R64)                     :: SensLoad
  REAL(R64)                     :: LatLoad
  REAL(R64)                     :: OnOffAirFlowRatio
  INTEGER                       :: CoilTypeNum
  INTEGER                       :: SpeedNum
  INTEGER                       :: CoilOutletNodeNum
  INTEGER                       :: CompIndex
  LOGICAL                       :: CoolLoad
  LOGICAL                       :: HeatLoad

  Dummy = 0.0d0

  IF(PRESENT(SpeedNumber))THEN
    SpeedNum = SpeedNumber
  ELSE
    SpeedNum = 1
  END IF

  IF (CoilType == CoolingCoil) THEN

    CompName     = UnitarySystem(UnitarySysNum)%CoolingCoilName
    CompIndex    = UnitarySystem(UnitarySysNum)%CoolingCoilIndex
    CoilTypeNum  = UnitarySystem(UnitarySysNum)%CoolingCoilType_Num
    CoilOutletNodeNum = UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum
    IF(SensibleLoad)THEN
      SensLoad = -1.0d0
      CoolLoad = .TRUE.
      HeatLoad = .FALSE.
    END IF
    IF(LatentLoad)LatLoad = -1.0d0

  ELSE

    CompName     = UnitarySystem(UnitarySysNum)%HeatingCoilName
    CompIndex    = UnitarySystem(UnitarySysNum)%HeatingCoilIndex
    CoilTypeNum  = UnitarySystem(UnitarySysNum)%HeatingCoilType_Num
    CoilOutletNodeNum = UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum

    IF(SensibleLoad)THEN
      SensLoad = 1.0d0
      CoolLoad = .FALSE.
      HeatLoad = .TRUE.
    ELSE
      SensLoad = 0.0d0
      HeatLoad = .FALSE.
    END IF
    LatLoad = 0.0d0
    UnitarySystem(UnitarySysNum)%FanOpMode = 1

  END IF

  OnOffAirFlowRatio = 1.0d0
  CALL SetOnOffMassFlowRate(UnitarySysNum, OnOffAirFlowRatio, PartLoadFrac) !1.0d0 = PartLoadRatio

  CALL CalcPassiveSystem(UnitarySysNum, FirstHVACIteration)

  SELECT CASE(CoilTypeNum)

    CASE(CoilDX_MultiSpeedCooling, CoilDX_MultiSpeedHeating)

      CALL SimDXCoilMultiSpeed(CompName,0.0d0,PartLoadFrac,CompIndex,SpeedNum,UnitarySystem(UnitarySysNum)%FanOpMode,1)

    CASE(Coil_CoolingAirToAirVariableSpeed)

       CALL SimVariableSpeedCoils(CompName,CompIndex, &
                   UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                   UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime, &
                   1, PartLoadFrac, OnOffAirFlowRatio,SpeedNum, 0.0d0,UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand,Dummy )

    CASE(Coil_HeatingAirToAirVariableSpeed)

       CALL SimVariableSpeedCoils(CompName,CompIndex, &
                   UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                   UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime, &
                   1, PartLoadFrac, OnOffAirFlowRatio,SpeedNum, 0.0d0,UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand,Dummy )

    CASE(Coil_CoolingWaterToAirHPVSEquationFit)

      CALL SimVariableSpeedCoils(CompName,CompIndex, &
                   UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                   UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime, &
                   1, PartLoadFrac, OnOffAirFlowRatio,SpeedNum, 0.0d0,UnitarySystem(UnitarySysNum)%CoolingCoilSensDemand,Dummy )

    CASE(Coil_HeatingWaterToAirHPVSEquationFit)

      CALL SimVariableSpeedCoils(CompName,CompIndex, &
                   UnitarySystem(UnitarySysNum)%FanOpMode,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                   UnitarySystem(UnitarySysNum)%HPTimeConstant,UnitarySystem(UnitarySysNum)%FanDelayTime, &
                   1, PartLoadFrac, OnOffAirFlowRatio,SpeedNum, 0.0d0,UnitarySystem(UnitarySysNum)%HeatingCoilSensDemand,Dummy )

    CASE(Coil_HeatingElectric_MultiStage, Coil_HeatingGas_MultiStage)

      CALL SimulateHeatingCoilComponents(CompName,FirstHVACIteration, &
                                         CompIndex     = CompIndex, &
                                         FanOpMode     = UnitarySystem(UnitarySysNum)%FanOpMode,      &
                                         PartLoadRatio = PartLoadFrac,  &
                                         StageNum      = SpeedNum,     &
                                         SpeedRatio    = 0.0d0)
    CASE DEFAULT

  END SELECT

  RETURN

END SUBROUTINE SimMultiSpeedCoils

SUBROUTINE CalcPassiveSystem(UnitarySysNum, FirstHVACIteration)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine calculates the set point based output of the unitary system.

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE Fans,             ONLY: SimulateFanComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN)          :: UnitarySysNum       ! Index of AirloopHVAC:UnitarySystem object
  LOGICAL, INTENT(IN)          :: FirstHVACIteration  ! True when first HVAC iteration
          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  REAL(R64)                     :: PartLoadRatio         ! coil operating part-load ratio
  REAL(R64)                     :: OnOffAirFlowRatio     ! Setpoint based coil control does not use this variable
  REAL(R64)                     :: CoilCoolHeatRat       ! ratio of cooling to heating PLR for cycling fan RH control
  REAL(R64)                     :: QZnReq
  INTEGER                       :: CompOn                ! compressor control (0=off, 1=on)
  LOGICAL                       :: HXUnitOn

  OnOffAirFlowRatio = 1.0d0
  CoilCoolHeatRat = 1.0d0
  QZnReq = 0.0d0
  !CALL the series of components that simulate a Unitary System
  IF (UnitarySystem(UnitarySysNum)%FanExists .AND. UnitarySystem(UnitarySysNum)%FanPlace .EQ. BlowThru) THEN
    CALL SimulateFanComponents(Blank,FirstHVACIteration,UnitarySystem(UnitarySysNum)%FanIndex,FanSpeedRatio)
  END IF

  IF(UnitarySystem(UnitarySysNum)%CoolingCoilUpstream)THEN

    IF (UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
      PartLoadRatio = UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac
      CompOn = 0
      IF(PartLoadRatio > 0.0d0)CompOn = 1
      HXUnitOn = .FALSE.
      CALL CalcUnitaryCoolingSystem(UnitarySysNum,FirstHVACIteration,PartLoadRatio, &
                                    CompOn,OnOffAirFlowRatio,CoilCoolHeatRat,HXUnitOn)
    END IF
    IF (UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
      PartLoadRatio = UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac
      CompOn = 0
      IF(PartLoadRatio > 0.0d0)CompOn = 1
      CALL CalcUnitaryHeatingSystem(UnitarySysNum,FirstHVACIteration,PartLoadRatio, CompOn, OnOffAirFlowRatio)
    END IF

  ELSE

    IF (UnitarySystem(UnitarySysNum)%HeatCoilExists)THEN
      PartLoadRatio = UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac
      CompOn = 0
      IF(PartLoadRatio > 0.0d0)CompOn = 1
      CALL CalcUnitaryHeatingSystem(UnitarySysNum,FirstHVACIteration,PartLoadRatio, CompOn, OnOffAirFlowRatio)
    END IF
    IF (UnitarySystem(UnitarySysNum)%CoolCoilExists)THEN
      PartLoadRatio = UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac
      CompOn = 0
      IF(PartLoadRatio > 0.0d0)CompOn = 1
      HXUnitOn = .FALSE.
      CALL CalcUnitaryCoolingSystem(UnitarySysNum,FirstHVACIteration,PartLoadRatio, &
                                    CompOn,OnOffAirFlowRatio,CoilCoolHeatRat,HXUnitOn)
    END IF

  END IF

  IF (UnitarySystem(UnitarySysNum)%FanExists .AND. UnitarySystem(UnitarySysNum)%FanPlace .EQ. DrawThru) THEN
    CALL SimulateFanComponents(Blank,FirstHVACIteration,UnitarySystem(UnitarySysNum)%FanIndex,FanSpeedRatio)
  END IF

! CALL reheat coils next
  IF (UnitarySystem(UnitarySysNum)%SuppCoilExists)THEN
    SuppHeatingCoilFlag = .TRUE.
    CALL CalcUnitarySuppSystemToSP(UnitarySysNum,FirstHVACIteration)
    SuppHeatingCoilFlag = .FALSE.
  END IF

  RETURN

END SUBROUTINE CalcPassiveSystem

SUBROUTINE SetOnOffMassFlowRate(UnitarySysNum, OnOffAirFlowRatio, PartLoadRatio)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Chandan Sharma
          !       DATE WRITTEN   May 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine is for initializations of the components.

          ! METHODOLOGY EMPLOYED:
          ! The unitarysystem may have alternate air flow rates
          ! in cooling, heating, and when no cooling or heating is needed. Set up the coil (comp) ON and OFF
          ! air flow rates. Use these flow rates during the Calc routines to set the average mass flow rates
          ! based on PLR.

          ! REFERENCES:
          ! Based on SetOnOffMassFlowRate by Richard Raustad

          ! USE STATEMENTS:
          ! na

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER,   INTENT(IN)    :: UnitarySysNum     ! index to unitary system
  REAL(r64), INTENT(INOUT) :: OnOffAirFlowRatio ! ratio of coil on to coil off air flow rate
  REAL(r64), INTENT(IN)    :: PartLoadRatio     ! coil part-load ratio

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
 INTEGER   :: HeatSpeedNum
 INTEGER   :: CoolSpeedNum
 REAL(R64) :: SpeedRatio

CompOffMassFlow  = 0.0d0
CompOffFlowRatio = 0.0d0

! Set the compressor or coil ON mass flow rate
IF ( HeatingLoad ) THEN

  UnitarySystem(UnitarySysNum)%LastMode = HeatingMode

  IF(MultiOrVarSpeedHeatCoil(UnitarySysNum)) THEN

    HeatSpeedNum = UnitarySystem(UnitarySysNum)%HeatingSpeedNum

    IF (HeatSpeedNum .EQ. 0) THEN
      CompOnMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
      CompOnFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
    ELSE IF (HeatSpeedNum .EQ. 1) THEN
      CompOnMassFlow  = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(1)
      CompOnFlowRatio = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(1)
      MSHPMassFlowRateLow  = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(1)
      MSHPMassFlowRateHigh = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(1)
    ELSEIF (HeatSpeedNum .GT. 1) THEN
      SpeedRatio       = UnitarySystem(UnitarySysNum)%HeatingSpeedRatio

      CompOnMassFlow   = SpeedRatio*UnitarySystem(UnitarySysNum)%HeatMassFlowRate(HeatSpeedNum) + &
                         (1.0d0-SpeedRatio)*UnitarySystem(UnitarySysNum)%HeatMassFlowRate(HeatSpeedNum-1)
      CompOnFlowRatio  = SpeedRatio*UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(HeatSpeedNum) + &
                         (1.0d0-SpeedRatio)*UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(HeatSpeedNum-1)
      MSHPMassFlowRateHigh = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(HeatSpeedNum)
      MSHPMassFlowRateLow  = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(HeatSpeedNum-1)
    END IF
    ! Set the compressor or coil OFF mass flow rate based on LOGICAL flag
    ! UseCompressorOnFlow is used when the user does not enter a value for no cooling or heating flow rate
    IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
      IF(MoistureLoad .LT. 0.0d0 .AND. UnitarySystem(UnitarySysNum)%Humidistat .AND. &
         UnitarySystem(UnitarySysNum)%DehumidControlType_Num == DehumidControl_CoolReheat)THEN
        IF (MultiOrVarSpeedCoolCoil(UnitarySysNum)) THEN
          CoolSpeedNum = UnitarySystem(UnitarySysNum)%CoolingSpeedNum
          IF(CoolSpeedNum .LT. 1)THEN
            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
          ELSEIF(CoolSpeedNum == 1) THEN
            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(1)
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(1)
          ELSEIF(CoolSpeedNum > 1) THEN
            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum-1)
          END IF
        ELSE
          CompOffMassFlow  = UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow
          CompOffFlowRatio = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
        END IF
      ELSE
!        IF (UnitarySystem(UnitarySysNum)%AirFlowControl .EQ. UseCompressorOnFlow) THEN
          IF(HeatSpeedNum <= 1)THEN
            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
          ELSE
            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(HeatSpeedNum-1)
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(HeatSpeedNum-1)
          END IF
      END IF
    END IF
  ELSE   ! IF(MultiOrVarSpeedHeatCoil) THEN
!   If a heating and moisture load exists, operate at the cooling mass flow rate ELSE operate at the heating flow rate
    IF(MoistureLoad .LT. 0.0d0 .AND. UnitarySystem(UnitarySysNum)%Humidistat .AND. &
       UnitarySystem(UnitarySysNum)%DehumidControlType_Num == DehumidControl_CoolReheat .AND. &
       .NOT. UnitarySystem(UnitarySysNum)%DXHeatingCoil)THEN
      IF (MultiOrVarSpeedCoolCoil(UnitarySysNum)) THEN
        CoolSpeedNum = UnitarySystem(UnitarySysNum)%CoolingSpeedNum
        IF(CoolSpeedNum .LT. 1)THEN
          CompOnMassFlow   = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
          CompOnFlowRatio  = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
        ELSEIF(CoolSpeedNum .EQ. 1)THEN
          CompOnMassFlow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(1)
          CompOnFlowRatio = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(1)
        ELSE
!          SpeedRatio           = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum)
          SpeedRatio           = UnitarySystem(UnitarySysNum)%CoolingSpeedRatio

          CompOnMassFlow       = SpeedRatio*UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum) + &
                                 (1.0d0-SpeedRatio)*UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
          CompOnFlowRatio      = SpeedRatio*UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum) + &
                                 (1.0d0-SpeedRatio)*UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum-1)
          MSHPMassFlowRateHigh = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum)
          MSHPMassFlowRateLow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
        END IF
      ELSE ! IF (MultiOrVarSpeedCoolCoil) THEN
        CompOnMassFlow   = UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow
        CompOnFlowRatio  = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
        IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
          CompOffMassFlow  = UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirMassFlow
          CompOffFlowRatio = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
        END IF
      END IF
    ELSE  ! Heating load but no moisture load
      CompOnMassFlow  = UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow
      CompOnFlowRatio = UnitarySystem(UnitarySysNum)%HeatingFanSpeedRatio
      IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
        IF (UnitarySystem(UnitarySysNum)%AirFlowControl .EQ. UseCompressorOnFlow) THEN
          CompOffMassFlow  = UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow
          CompOffFlowRatio = UnitarySystem(UnitarySysNum)%HeatingFanSpeedRatio
        ELSE
          CompOffMassFlow  = UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirMassFlow
          CompOffFlowRatio = UnitarySystem(UnitarySysNum)%HeatingFanSpeedRatio
        END IF
      END IF
    END IF
  END IF

! If a cooling load exists, operate at the cooling mass flow rate
ELSEIF ( CoolingLoad ) THEN

  UnitarySystem(UnitarySysNum)%LastMode = CoolingMode

  IF(MultiOrVarSpeedCoolCoil(UnitarySysNum)) THEN

    CoolSpeedNum = UnitarySystem(UnitarySysNum)%CoolingSpeedNum

    IF (CoolSpeedNum .EQ. 0) THEN
      CompOnMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
      CompOnFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
    ELSE IF (CoolSpeedNum .EQ. 1) THEN
      CompOnMassFlow       = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(1)
      CompOnFlowRatio      = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(1)
      MSHPMassFlowRateLow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(1)
      MSHPMassFlowRateHigh = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(1)
    ELSEIF (CoolSpeedNum .GT. 1) THEN
!      SpeedRatio           = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum)
      SpeedRatio           = UnitarySystem(UnitarySysNum)%CoolingSpeedRatio

      CompOnMassFlow       = SpeedRatio * UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum) + &
                             (1.0d0-SpeedRatio) * UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
      CompOnFlowRatio      = SpeedRatio * UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum) + &
                             (1.0d0-SpeedRatio) * UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum-1)
      MSHPMassFlowRateHigh = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum)
      MSHPMassFlowRateLow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
    END IF
    ! Set the compressor or coil OFF mass flow rate based on LOGICAL flag
    ! UseCompressorOnFlow is used when the user does not enter a value for no cooling or heating flow rate
!    IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
!      IF (UnitarySystem(UnitarySysNum)%AirFlowControl .EQ. UseCompressorOnFlow) THEN
        IF(CoolSpeedNum <= 1)THEN
          IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
          END IF
        ELSE
          CompOffMassFlow = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
          CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum-1)
        END IF
!      ELSE
!        CompOffMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
!        CompOffFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
!      END IF
!    END IF
  ELSE ! IF(MultiOrVarSpeedCoolCoil(UnitarySysNum)) THEN
    CompOnMassFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow
    CompOnFlowRatio = UnitarySystem(UnitarySysNum)%CoolingSpeedRatio
    IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
      IF (UnitarySystem(UnitarySysNum)%AirFlowControl .EQ. UseCompressorOnFlow) THEN
        CompOffMassFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow
        CompOffFlowRatio = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
      ELSE
        CompOffMassFlow = UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirMassFlow
        CompOffFlowRatio = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
      END IF
    END IF
  END IF

ELSE  ! No load
! If no load exists, set the compressor on mass flow rate.
! Set equal the mass flow rate when no heating or cooling is needed If no moisture load exists.
! If the user has set the off mass flow rate to 0, set according to the last operating mode.

  IF(MoistureLoad .LT. 0.0d0 .AND. UnitarySystem(UnitarySysNum)%Humidistat .AND. &
     UnitarySystem(UnitarySysNum)%DehumidControlType_Num == DehumidControl_CoolReheat)THEN
    IF (MultiOrVarSpeedCoolCoil(UnitarySysNum)) THEN
      CoolSpeedNum = UnitarySystem(UnitarySysNum)%CoolingSpeedNum
      IF(CoolSpeedNum .LT. 1)THEN
        CompOnMassFlow   = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
        CompOnFlowRatio  = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
      ELSEIF(CoolSpeedNum .EQ. 1)THEN
        CompOnMassFlow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(1)
        CompOnFlowRatio = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(1)
      ELSE
!        SpeedRatio           = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum)
        SpeedRatio           = UnitarySystem(UnitarySysNum)%CoolingSpeedRatio

        CompOnMassFlow       = SpeedRatio * UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum) + &
                               (1.0d0-SpeedRatio) * UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
        CompOnFlowRatio      = SpeedRatio * UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum) + &
                               (1.0d0-SpeedRatio) * UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum-1)
        MSHPMassFlowRateHigh = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum)
        MSHPMassFlowRateLow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
      END IF

      IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
        IF (UnitarySystem(UnitarySysNum)%AirFlowControl .EQ. UseCompressorOnFlow) THEN
          IF(CoolSpeedNum <= 1)THEN
            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
          ELSE
            CompOffMassFlow = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum-1)
          END IF
        ELSE
          CompOffMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
          CompOffFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
        END IF
      END IF

    ELSE  ! IF (MultiOrVarSpeedCoolCoil(UnitarySysNum)) THEN
      CompOnMassFlow = UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow
      CompOnFlowRatio = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
      IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
        IF (UnitarySystem(UnitarySysNum)%AirFlowControl .EQ. UseCompressorOnFlow) THEN
          CompOffMassFlow  = UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow
          CompOffFlowRatio = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
        ELSE
          CompOffMassFlow  = UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirMassFlow
          CompOffFlowRatio = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
        END IF
      END IF
    END IF

  ELSE ! No Moisture Load

    IF(UnitarySystem(UnitarySysNum)%LastMode .EQ. HeatingMode)THEN
      IF(MultiOrVarSpeedHeatCoil(UnitarySysNum)) THEN
        CompOnMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
        CompOnFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
      ELSE
        CompOnMassFlow  = UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirMassFlow
        CompOnFlowRatio = 1.0d0
      END IF
    ELSE
      IF(MultiOrVarSpeedCoolCoil(UnitarySysNum)) THEN
        CompOnMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
        CompOnFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
      ELSE
        CompOnMassFlow  = UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirMassFlow
        CompOnFlowRatio = 1.0d0
      END IF
    END IF
    IF(CompOnMassFlow .EQ. 0.0d0)THEN
      IF(UnitarySystem(UnitarySysNum)%LastMode .EQ. HeatingMode)THEN
        IF(MultiOrVarSpeedHeatCoil(UnitarySysNum)) THEN
          HeatSpeedNum = UnitarySystem(UnitarySysNum)%HeatingSpeedNum
          IF (HeatSpeedNum .EQ. 0) THEN
            CompOnMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
            CompOnFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
          ELSE IF (HeatSpeedNum .EQ. 1) THEN
            CompOnMassFlow   = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(1)
            CompOnFlowRatio  = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(1)
!            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
!            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
          ELSEIF (HeatSpeedNum .GT. 1) THEN
            CompOnMassFlow   = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(HeatSpeedNum)
            CompOnFlowRatio  = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(HeatSpeedNum)
!            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(HeatSpeedNum-1)
!            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(HeatSpeedNum-1)
          END IF
        ELSE  ! IF(MultiOrVarSpeedHeatCoil) THEN
          CompOnMassFlow  = UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow
          CompOnFlowRatio = UnitarySystem(UnitarySysNum)%HeatingFanSpeedRatio
        END IF
      ELSE   ! IF(UnitarySystem(UnitarySysNum)%LastMode .EQ. HeatingMode)THEN
        IF(MultiOrVarSpeedCoolCoil(UnitarySysNum)) THEN
          CoolSpeedNum = UnitarySystem(UnitarySysNum)%CoolingSpeedNum
          IF (CoolSpeedNum .EQ. 0) THEN
            CompOnMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
            CompOnFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
          ELSE IF (CoolSpeedNum .EQ. 1) THEN
            CompOnMassFlow   = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(1)
            CompOnFlowRatio  = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(1)
!            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
!            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
          ELSEIF (CoolSpeedNum .GT. 1) THEN
            CompOnMassFlow   = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum)
            CompOnFlowRatio  = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum)
!            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
!            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum-1)
          END IF
        ELSE  ! IF(MultiOrVarSpeedCoolCoil) THEN
          CompOnMassFlow  = UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow
          CompOnFlowRatio = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
        END IF ! IF(MultiOrVarSpeedCoolCoil) THEN
      END IF   ! IF(UnitarySystem(UnitarySysNum)%LastMode .EQ. HeatingMode)THEN
    END IF ! IF(CompOnMassFlow .EQ. 0.0d0)THEN

    IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
      IF (UnitarySystem(UnitarySysNum)%AirFlowControl .EQ. UseCompressorOnFlow) THEN
        IF(UnitarySystem(UnitarySysNum)%LastMode .EQ. HeatingMode)THEN
          IF(MultiOrVarSpeedHeatCoil(UnitarySysNum)) THEN
            HeatSpeedNum = UnitarySystem(UnitarySysNum)%HeatingSpeedNum
            IF(HeatSpeedNum<1)THEN
              CompOffMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
              CompOffFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
            ELSE IF(HeatSpeedNum==1)THEN
              CompOffMassFlow  = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(1)
              CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(1)
            ELSE
              CompOffMassFlow  = UnitarySystem(UnitarySysNum)%HeatMassFlowRate(HeatSpeedNum-1)
              CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(HeatSpeedNum-1)
            END IF
          ELSE
            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%HeatingFanSpeedRatio
          END IF
        ELSE   ! IF(UnitarySystem(UnitarySysNum)%LastMode .EQ. HeatingMode)THEN
          IF(MultiOrVarSpeedCoolCoil(UnitarySysNum)) THEN
            CoolSpeedNum = UnitarySystem(UnitarySysNum)%CoolingSpeedNum
            IF(CoolSpeedNum<1)THEN
              CompOffMassFlow  = UnitarySystem(UnitarySysNum)%IdleMassFlowRate
              CompOffFlowRatio = UnitarySystem(UnitarySysNum)%IdleSpeedRatio
            ELSE IF(CoolSpeedNum==1)THEN
              CompOffMassFlow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(1)
              CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(1)
            ELSE
              CompOffMassFlow  = UnitarySystem(UnitarySysNum)%CoolMassFlowRate(CoolSpeedNum-1)
              CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(CoolSpeedNum-1)
            END IF
          ELSE
            CompOffMassFlow  = UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
          END IF
        END IF   ! IF(UnitarySystem(UnitarySysNum)%LastMode .EQ. HeatingMode)THEN
      ELSE  ! IF (UnitarySystem(UnitarySysNum)%AirFlowControl .EQ. UseCompressorOnFlow) THEN
        CompOffMassFlow  = UnitarySystem(UnitarySysNum)%MaxNoCoolHeatAirMassFlow
        IF(UnitarySystem(UnitarySysNum)%LastMode .EQ. HeatingMode)THEN
          IF(MultiOrVarSpeedHeatCoil(UnitarySysNum)) THEN
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSHeatingSpeedRatio(1)
          ELSE
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%HeatingFanSpeedRatio
          END IF
        ELSE
          IF(MultiOrVarSpeedCoolCoil(UnitarySysNum)) THEN
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%MSCoolingSpeedRatio(1)
          ELSE
            CompOffFlowRatio = UnitarySystem(UnitarySysNum)%CoolingFanSpeedRatio
          END IF
        END IF
      END IF ! IF (UnitarySystem(UnitarySysNum)%AirFlowControl .EQ. UseCompressorOnFlow) THEN
    END IF   ! IF(UnitarySystem(UnitarySysNum)%FanOpMode == ContFanCycCoil)THEN
  END IF     ! ELSE ! No Moisture Load
END IF       ! No Heating/Cooling Load

! Set the system mass flow rates
CALL SetAverageAirFlow(UnitarySysNum, PartLoadRatio, OnOffAirFlowRatio)

END SUBROUTINE SetOnOffMassFlowRate

SUBROUTINE SetAverageAirFlow(UnitarySysNum,PartLoadRatio,OnOffAirFlowRatio)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2005
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS SUBROUTINE:
          ! Set the average air mass flow rates using the part-load fraction of the HVAC system for this time step
          ! Set OnOffAirFlowRatio to be used by DX coils

          ! METHODOLOGY EMPLOYED:
          ! The air flow rate in cooling, heating, and no cooling or heating can be dIFferent.
          ! Calculate the air flow rate based on initializations.

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE DataZoneEnergyDemands

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER,   INTENT (IN)    :: UnitarySysNum   ! Unit index
  REAL(r64), INTENT (IN)    :: PartLoadRatio      ! unit part load ratio
  REAL(r64), INTENT (INOUT) :: OnOffAirFlowRatio  ! ratio of compressor ON airflow to AVERAGE airflow over timestep

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER             :: InletNode           ! inlet node number
  REAL(r64)           :: AverageUnitMassFlow ! average supply air mass flow rate over time step
  INTEGER             :: SpeedNum            ! speed for multi-speed or variable-speed coils
  LOGICAL             :: FanOn

  SpeedNum  = MAX(UnitarySystem(UnitarySysNum)%CoolingSpeedNum,UnitarySystem(UnitarySysNum)%HeatingSpeedNum)
  InletNode = UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum

  IF(SpeedNum > 1)THEN
    AverageUnitMassFlow = CompOnMassFlow
  ELSE
    AverageUnitMassFlow = (PartLoadRatio * CompOnMassFlow) + ((1.0d0-PartLoadRatio) * CompOffMassFlow)
  END IF
  IF(CompOffFlowRatio .GT. 0.0d0)THEN
    IF(SpeedNum > 1)THEN
      FanSpeedRatio = CompOnFlowRatio
    ELSE
      FanSpeedRatio = (PartLoadRatio * CompOnFlowRatio) + ((1.0d0-PartLoadRatio) * CompOffFlowRatio)
    END IF
  ELSE
    FanSpeedRatio     = CompOnFlowRatio
  END IF
! If the unitary system is scheduled on or nightime cycle overrides fan schedule. Uses same logic as fan.
  IF(UnitarySystem(UnitarySysNum)%FanExists)THEN
    FanOn=.FALSE.
    IF(GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%FanAvailSchedPtr) .GT. 0)FanOn=.TRUE.
  ELSE
    FanOn=.TRUE.
  END IF
  IF ( GetCurrentScheduleValue(UnitarySystem(UnitarySysNum)%SysAvailSchedPtr) .GT. 0.0d0 .AND. &
     ( (FanOn .OR. TurnFansOn) .AND. .NOT. TurnFansOff) ) THEN
    Node(InletNode)%MassFlowRate              = AverageUnitMassFlow
    Node(InletNode)%MassFlowRateMaxAvail      = AverageUnitMassFlow
    IF (AverageUnitMassFlow .GT. 0.0d0) THEN
      OnOffAirFlowRatio                       = CompOnMassFlow / AverageUnitMassFlow
    ELSE
      OnOffAirFlowRatio                       = 0.0d0
    END IF
  ELSE
    Node(InletNode)%MassFlowRate              = 0.0d0
    OnOffAirFlowRatio                         = 1.0d0
  END IF

  RETURN
END SUBROUTINE SetAverageAirFlow

SUBROUTINE ReportUnitarySystem(UnitarySysNum, AirLoopNum)


          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Chandan Sharma
          !       DATE WRITTEN   July 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na


          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine updates the report variable for the coils.


          ! METHODOLOGY EMPLOYED:
          !

          ! REFERENCES:
          ! na


          ! USE STATEMENTS:
  USE Psychrometrics,        ONLY: PsyHFnTdbW
  USE DataAirLoop, ONLY: LoopSystemOnMassFlowrate,LoopSystemOffMassFlowrate,LoopFanOperationMode,LoopOnOffFanPartLoadRatio, &
                         LoopCompCycRatio, AirLoopFlow

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine


          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT(IN) :: UnitarySysNum
  INTEGER, INTENT(IN) :: AirLoopNum


          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na


          ! INTERFACE BLOCK SPECIFICATIONS
          ! na


          ! DERIVED TYPE DEFINITIONS
          ! na


          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
      INTEGER      :: OutletNode
      INTEGER      :: InletNode
      REAL(r64)    :: QSensUnitOut
      REAL(r64)    :: QTotUnitOut
      REAL(r64)    :: AirMassFlow
      REAL(r64)    :: MinHumRatio
      REAL(r64)    :: CompPartLoadFrac
      REAL(r64)    :: ReportingConstant

      ReportingConstant = TimeStepSys*SecInHour

      QTotUnitOut = 0.0d0
      QSensUnitOut = 0.0d0
      UnitarySystem(UnitarySysNum)%PartLoadFrac              = 0.0d0
      UnitarySystem(UnitarySysNum)%CompPartLoadRatio         = 0.0d0
      UnitarySystem(UnitarySysNum)%CycRatio                  = 0.0d0
      UnitarySystem(UnitarySysNum)%SpeedRatio                = 0.0d0
      UnitarySystem(UnitarySysNum)%FanPartLoadRatio          = 0.0d0
      UnitarySystem(UnitarySysNum)%TotalAuxElecPower         = 0.0d0
      UnitarySystem(UnitarySysNum)%HeatingAuxElecConsumption = 0.0d0
      UnitarySystem(UnitarySysNum)%CoolingAuxElecConsumption = 0.0d0
      UnitarySystem(UnitarySysNum)%ElecPower                 = 0.0d0
      UnitarySystem(UnitarySysNum)%ElecPowerConsumption      = 0.0d0

      OutletNode  = UnitarySystem(UnitarySysNum)%UnitarySystemOutletNodeNum
      AirMassFlow = Node(OutletNode)%MassFlowRate
      SELECT CASE(UnitarySystem(UnitarySysNum)%ControlType)
        CASE(SetPointBased)
          InletNode  = UnitarySystem(UnitarySysNum)%UnitarySystemInletNodeNum
          MinHumRatio  = Node(InletNode)%HumRat
          QSensUnitOut = AirMassFlow * (PsyHFnTdbW(Node(OutletNode)%Temp,MinHumRatio)  &
                            - PsyHFnTdbW(Node(InletNode)%Temp,MinHumRatio)) &
                            - UnitarySystem(UnitarySysNum)%SenLoadLoss
          QTotUnitOut  = AirMassFlow * (Node(OutletNode)%Enthalpy - &
                         Node(InletNode)%Enthalpy)

        CASE(LoadBased)
          MinHumRatio  = Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%HumRat
          QSensUnitOut = AirMassFlow * (PsyHFnTdbW(Node(OutletNode)%Temp,MinHumRatio)  &
                           - PsyHFnTdbW(Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%Temp,MinHumRatio)) &
                           - UnitarySystem(UnitarySysNum)%SenLoadLoss
          QTotUnitOut  = AirMassFlow * (Node(OutletNode)%Enthalpy - &
                         Node(UnitarySystem(UnitarySysNum)%NodeNumofControlledZone)%Enthalpy)

        CASE DEFAULT

      END SELECT

      ! set the system part-load ratio report variable
      UnitarySystem(UnitarySysNum)%PartLoadFrac = MAX(UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac, &
                                                      UnitarySystem(UnitarySysNum)%HeatingPartLoadFrac)
      ! set the compressor part-load ratio report variable
      SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)
        CASE(CoilDX_HeatingEmpirical, CoilDX_MultiSpeedHeating, Coil_HeatingWaterToAirHP, &
             Coil_HeatingWaterToAirHPSimple, Coil_HeatingWaterToAirHPVSEquationFit, Coil_HeatingAirToAirVariableSpeed)
! wasn't this already set in the calc routine?
! they look wrong anyway since the compressor can be off when the fan is on
!          UnitarySystem(UnitarySysNum)%CompPartLoadRatio = UnitarySystem(UnitarySysNum)%PartLoadFrac
        CASE DEFAULT
!          UnitarySystem(UnitarySysNum)%CompPartLoadRatio = UnitarySystem(UnitarySysNum)%CoolingPartLoadFrac
      END SELECT
      UnitarySystem(UnitarySysNum)%CompPartLoadRatio = MAX(UnitarySystem(UnitarySysNum)%CoolCompPartLoadRatio, &
                                                           UnitarySystem(UnitarySysNum)%HeatCompPartLoadRatio)

      IF (HeatingLoad) THEN
        UnitarySystem(UnitarySysNum)%TotCoolEnergyRate  = 0.0d0
        UnitarySystem(UnitarySysNum)%SensCoolEnergyRate = 0.0d0
        UnitarySystem(UnitarySysNum)%LatCoolEnergyRate  = 0.0d0
        UnitarySystem(UnitarySysNum)%TotHeatEnergyRate  = ABS(MAX(0.0d0, QTotUnitOut))
        UnitarySystem(UnitarySysNum)%SensHeatEnergyRate = ABS(MAX(0.0d0, QSensUnitOut))
        UnitarySystem(UnitarySysNum)%LatHeatEnergyRate  = ABS(MAX(0.0d0, (QTotUnitOut - QSensUnitOut)))
      ELSE
        UnitarySystem(UnitarySysNum)%TotCoolEnergyRate  = ABS(MIN(0.0d0, QTotUnitOut))
        UnitarySystem(UnitarySysNum)%SensCoolEnergyRate = ABS(MIN(0.0d0, QSensUnitOut))
        UnitarySystem(UnitarySysNum)%LatCoolEnergyRate  = ABS(MIN(0.0d0, (QTotUnitOut - QSensUnitOut)))
        UnitarySystem(UnitarySysNum)%TotHeatEnergyRate  = 0.0d0
        UnitarySystem(UnitarySysNum)%SensHeatEnergyRate = 0.0d0
        UnitarySystem(UnitarySysNum)%LatHeatEnergyRate  = 0.0d0
      END IF

      IF (UnitarySystem(UnitarySysNum)%FanExists) THEN
        IF (CompOnMassFlow .GT. 0.0d0) THEN
          UnitarySystem(UnitarySysNum)%FanPartLoadRatio = Node(OutletNode)%MassFlowRate / CompOnMassFlow
        ELSE
          UnitarySystem(UnitarySysNum)%FanPartLoadRatio = 0.0d0
        END IF
        IF(AirLoopNum .GT. 0)THEN
          IF(UnitarySystem(UnitarySysNum)%FanOpMode == CycFanCycCoil)THEN
            AirLoopflow(AirLoopNum)%FanPLR = UnitarySystem(UnitarySysNum)%FanPartLoadRatio
          ELSE
            AirLoopflow(AirLoopNum)%FanPLR = 0.0d0
          END IF
        END IF
      END IF

      SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

        CASE(CoilDX_CoolingTwoSpeed)
          ! need to make sure these are 0 for non-variable speed coils (or not report these variables)
          UnitarySystem(UnitarySysNum)%CycRatio     = MAX(UnitarySystem(UnitarySysNum)%CoolingCycRatio,     &
                                                          UnitarySystem(UnitarySysNum)%HeatingCycRatio)
          UnitarySystem(UnitarySysNum)%SpeedRatio   = MAX(UnitarySystem(UnitarySysNum)%CoolingSpeedRatio,   &
                                                          UnitarySystem(UnitarySysNum)%HeatingSpeedRatio)
          UnitarySystem(UnitarySysNum)%SpeedNum     = MAX(UnitarySystem(UnitarySysNum)%CoolingSpeedNum,   &
                                                          UnitarySystem(UnitarySysNum)%HeatingSpeedNum)

        CASE(CoilDX_MultiSpeedCooling)
          UnitarySystem(UnitarySysNum)%CycRatio     = MAX(UnitarySystem(UnitarySysNum)%CoolingCycRatio,     &
                                                          UnitarySystem(UnitarySysNum)%HeatingCycRatio)
          UnitarySystem(UnitarySysNum)%SpeedRatio   = MAX(UnitarySystem(UnitarySysNum)%CoolingSpeedRatio,   &
                                                          UnitarySystem(UnitarySysNum)%HeatingSpeedRatio)
          UnitarySystem(UnitarySysNum)%SpeedNum     = MAX(UnitarySystem(UnitarySysNum)%CoolingSpeedNum,   &
                                                          UnitarySystem(UnitarySysNum)%HeatingSpeedNum)

          CompPartLoadFrac = UnitarySystem(UnitarySysNum)%CompPartLoadRatio
          IF (CoolingLoad) THEN

            UnitarySystem(UnitarySysNum)%TotalAuxElecPower  = UnitarySystem(UnitarySysNum)%AncillaryOnPower * CompPartLoadFrac + &
                                                         UnitarySystem(UnitarySysNum)%AncillaryOffPower * (1.0d0-CompPartLoadFrac)
            UnitarySystem(UnitarySysNum)%CoolingAuxElecConsumption = UnitarySystem(UnitarySysNum)%AncillaryOnPower * &
                                                                   CompPartLoadFrac * ReportingConstant
          END IF
          IF (UnitarySystem(UnitarySysNum)%LastMode .EQ. CoolingMode) THEN
            UnitarySystem(UnitarySysNum)%CoolingAuxElecConsumption = UnitarySystem(UnitarySysNum)%CoolingAuxElecConsumption + &
                              UnitarySystem(UnitarySysNum)%AncillaryOffPower*(1.0d0-CompPartLoadFrac)*ReportingConstant

          END IF
          UnitarySystem(UnitarySysNum)%ElecPower = FanElecPower + DXElecCoolingPower + DXElecHeatingPower + &
                                                   ElecHeatingCoilPower + UnitarySystem(UnitarySysNum)%TotalAuxElecPower
          UnitarySystem(UnitarySysNum)%ElecPowerConsumption = UnitarySystem(UnitarySysNum)%ElecPower * ReportingConstant

        CASE DEFAULT

      END SELECT

      SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)

        CASE(CoilDX_MultiSpeedHeating)
          UnitarySystem(UnitarySysNum)%CycRatio     = MAX(UnitarySystem(UnitarySysNum)%CoolingCycRatio,     &
                                                          UnitarySystem(UnitarySysNum)%HeatingCycRatio)
          UnitarySystem(UnitarySysNum)%SpeedRatio   = MAX(UnitarySystem(UnitarySysNum)%CoolingSpeedRatio,   &
                                                          UnitarySystem(UnitarySysNum)%HeatingSpeedRatio)

          CompPartLoadFrac = UnitarySystem(UnitarySysNum)%CompPartLoadRatio
          IF (HeatingLoad) THEN

            UnitarySystem(UnitarySysNum)%TotalAuxElecPower  = UnitarySystem(UnitarySysNum)%AncillaryOnPower * CompPartLoadFrac + &
                                                         UnitarySystem(UnitarySysNum)%AncillaryOffPower * (1.0d0-CompPartLoadFrac)
            UnitarySystem(UnitarySysNum)%HeatingAuxElecConsumption = UnitarySystem(UnitarySysNum)%AncillaryOnPower * &
                                                                     CompPartLoadFrac * ReportingConstant
          END IF
          IF (UnitarySystem(UnitarySysNum)%LastMode .EQ. HeatingMode) THEN
            UnitarySystem(UnitarySysNum)%HeatingAuxElecConsumption = UnitarySystem(UnitarySysNum)%HeatingAuxElecConsumption + &
                                UnitarySystem(UnitarySysNum)%AncillaryOffPower*(1.0d0-CompPartLoadFrac)*ReportingConstant

          END IF
          UnitarySystem(UnitarySysNum)%ElecPower = FanElecPower + DXElecCoolingPower + DXElecHeatingPower + &
                                                   UnitarySystem(UnitarySysNum)%TotalAuxElecPower
          UnitarySystem(UnitarySysNum)%ElecPowerConsumption = UnitarySystem(UnitarySysNum)%ElecPower * ReportingConstant

        CASE(Coil_HeatingGas_MultiStage, Coil_HeatingElectric_MultiStage)
          UnitarySystem(UnitarySysNum)%CycRatio     = MAX(UnitarySystem(UnitarySysNum)%CoolingCycRatio,     &
                                                          UnitarySystem(UnitarySysNum)%HeatingCycRatio)
          UnitarySystem(UnitarySysNum)%SpeedRatio   = MAX(UnitarySystem(UnitarySysNum)%CoolingSpeedRatio,   &
                                                          UnitarySystem(UnitarySysNum)%HeatingSpeedRatio)

          UnitarySystem(UnitarySysNum)%ElecPower = FanElecPower + DXElecCoolingPower + &
                                                   ElecHeatingCoilPower + UnitarySystem(UnitarySysNum)%TotalAuxElecPower
          UnitarySystem(UnitarySysNum)%ElecPowerConsumption = UnitarySystem(UnitarySysNum)%ElecPower * ReportingConstant

        CASE DEFAULT

      END SELECT

  LoopSystemOnMassFlowrate = CompOnMassFlow
  LoopSystemOffMassFlowrate = CompOffMassFlow
  LoopFanOperationMode = UnitarySystem(UnitarySysNum)%FanOpMode
  LoopOnOffFanPartLoadRatio = UnitarySystem(UnitarySysNum)%FanPartLoadRatio
  LoopCompCycRatio = UnitarySystem(UnitarySysNum)%CycRatio

  IF(CurOASysNum > 0)THEN
    OASysEqSizing(CurOASysNum)%AirFlow = .FALSE.
    OASysEqSizing(CurOASysNum)%Capacity = .FALSE.
  ELSE IF(CurSysNum > 0)THEN
    UnitarySysEqSizing(CurSysNum)%AirFlow = .FALSE.
    UnitarySysEqSizing(CurSysNum)%Capacity = .FALSE.
    AirLoopControlInfo(CurSysNum)%UnitarySysSimulating = .FALSE.
  ELSE IF(CurZoneEqNum > 0)THEN
    ZoneEqSizing(CurZoneEqNum)%AirFlow = .FALSE.
    ZoneEqSizing(CurZoneEqNum)%Capacity = .FALSE.
  END IF

RETURN
END SUBROUTINE ReportUnitarySystem

SUBROUTINE UnitarySystemHeatRecovery(UnitarySysNum)

            ! SUBROUTINE INFORMATION:
            !       AUTHOR:          Chandan Sharma
            !       DATE WRITTEN:    May 2013
            !       MODIFIED:        na
            !       RE-ENGINEERED    na

            ! PURPOSE OF THIS SUBROUTINE:
            !  Calculate the heat recovered from UnitarySystem

            ! METHODOLOGY EMPLOYED:
            !  na

            ! REFERENCES:
            !  na

            ! USE STATEMENTS:
  USE FluidProperties,     ONLY: GetSpecificHeatGlycol
  USE DataPlant,           ONLY: PlantLoop
  USE PlantUtilities,      ONLY: SafeCopyPlantNode

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER, INTENT (IN)     :: UnitarySysNum ! Number of the current electric UnitarySystem being simulated

          ! SUBROUTINE PARAMETER DEFINITIONS:
          !  na

          ! DERIVMS TYPE DEFINITIONS:
          !  na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER      :: HeatRecInNode       ! Node number of heat recovery water inlet node
  INTEGER      :: HeatRecOutNode      ! Node number of heat recovery water outlet node
  REAL(r64)    :: QHeatRec            ! Total heat recovered [W]
  REAL(r64)    :: HeatRecInletTemp    ! Heat reclaim inlet temp [C]
  REAL(r64)    :: HeatRecOutletTemp   ! Heat reclaim outlet temp [C]
  REAL(r64)    :: HeatRecMassFlowRate ! Heat reclaim mass flow rate [m3/s]
  REAL(r64)    :: CpHeatRec           ! Heat reclaim water inlet specIFic heat [J/kg-K]
  REAL(r64)    :: HeatRecInletEnth    ! Heat reclaim water inlet enthalpy [J/kg]
  REAL(r64)    :: ReportingConstant

  ReportingConstant = TimeStepSys*SecInHour

  ! Begin routine
  HeatRecInNode  = UnitarySystem(UnitarySysNum)%HeatRecoveryInletNodeNum
  HeatRecOutNode = UnitarySystem(UnitarySysNum)%HeatRecoveryOutletNodeNum

   ! Inlet node to the heat recovery heat exchanger
  HeatRecInletTemp  = Node(HeatRecInNode)%Temp
  HeatRecInletEnth  = Node(HeatRecInNode)%Enthalpy

   ! Set heat recovery mass flow rates
  HeatRecMassFlowRate = Node(HeatRecInNode)%MassFlowRate

  QHeatRec = MSHPWasteHeat

  IF (HeatRecMassFlowRate > 0.0d0) THEN

    CpHeatRec = GetSpecificHeatGlycol(PlantLoop(UnitarySystem(UnitarySysNum)%HRLoopNum)%FluidName, &
                                      HeatRecInletTemp, &
                                      PlantLoop(UnitarySystem(UnitarySysNum)%HRLoopNum)%FluidIndex, &
                                      'UnitarySystemHeatRecovery')

    HeatRecOutletTemp = QHeatRec/(HeatRecMassFlowRate*CpHeatRec) + HeatRecInletTemp
    IF (HeatRecOutletTemp .GT. UnitarySystem(UnitarySysNum)%MaxHROutletWaterTemp) &
        HeatRecOutletTemp = UnitarySystem(UnitarySysNum)%MaxHROutletWaterTemp
  ELSE
    HeatRecOutletTemp = HeatRecInletTemp
  END IF

  CALL SafeCopyPlantNode(HeatRecInNode, HeatRecOutNode)
  ! changed outputs
  Node(HeatRecOutNode)%Temp         = HeatRecOutletTemp

  UnitarySystem(UnitarySysNum)%HeatRecoveryRate         = QHeatRec
  UnitarySystem(UnitarySysNum)%HeatRecoveryEnergy       = UnitarySystem(UnitarySysNum)%HeatRecoveryRate*ReportingConstant
  UnitarySystem(UnitarySysNum)%HeatRecoveryInletTemp    = HeatRecInletTemp
  UnitarySystem(UnitarySysNum)%HeatRecoveryOutletTemp   = HeatRecOutletTemp
  UnitarySystem(UnitarySysNum)%HeatRecoveryMassFlowRate = HeatRecMassFlowRate

  RETURN

END SUBROUTINE UnitarySystemHeatRecovery

FUNCTION DXHeatingCoilResidual(PartLoadFrac, Par) RESULT (Residuum)
          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   June 2006
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls CalcDOe2DXCoil to get outlet temperature at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils, ONLY: DXCoilOutletTemp, CalcDXHeatingCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadFrac               ! Compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! Par(1) = DX coil number
                                                    ! Par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum                   ! Residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER      :: CoilIndex        ! Index of this coil
  REAL(r64)    :: OutletAirTemp    ! Outlet air temperature [C]
  REAL(r64)    :: OnOffAirFlowFrac ! Ratio of compressor ON to compressor OFF air mass flow rate

  CoilIndex        = INT(Par(1))
  OnOffAirFlowFrac = Par(3)

  CALL CalcDXHeatingCoil(CoilIndex,PartLoadFrac,ContFanCycCoil,OnOffAirFlowFrac)

  OutletAirTemp = DXCoilOutletTemp(CoilIndex)
  Residuum      = Par(2) - OutletAirTemp

  RETURN
END FUNCTION DXHeatingCoilResidual

FUNCTION DXCoilVarSpeedResidual(SpeedRatio, Par) RESULT (Residuum)
          ! FUNCTION INFORMATION:
          !       AUTHOR         Fred Buhl
          !       DATE WRITTEN   September 2002
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp).
          ! DX Coil output depends on the compressor speed which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls CalcMultiSpeedDXCoil to get outlet temperature at the given compressor speed
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils,                   ONLY: DXCoilOutletTemp, CalcMultiSpeedDXCoil, CalcMultiSpeedDXCoilCooling
  USE VariableSpeedCoils,        ONLY: CalcVarSpeedCoilCooling

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: SpeedRatio ! compressor speed ratio (1.0 is max, 0.0 is min)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex        ! index of this coil
  INTEGER   :: UnitarySysNum ! index to Unitary System
  REAL(r64) :: OutletAirTemp   ! outlet air temperature [C]
  REAL(r64) :: CycRatio
  INTEGER   :: SpeedNum
  INTEGER   :: FanOpMode
  INTEGER   :: CompOp
  REAL(r64) :: ReqOutput
  REAL(r64) :: dummy
  REAL(r64) :: RuntimeFrac
  REAL(r64) :: OnOffAirFlowRatio


  CoilIndex     = INT(Par(1))
  UnitarySysNum = INT(Par(3))

  SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

    CASE (CoilDX_CoolingTwoSpeed)

      CALL CalcMultiSpeedDXCoil(CoilIndex,SpeedRatio,1.0d0)
      OutletAirTemp = DXCoilOutletTemp(CoilIndex)

    CASE (CoilDX_MultiSpeedCooling)

      CycRatio = Par(4)
      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))
      CompOp     = INT(Par(7))

      CALL CalcMultiSpeedDXCoilCooling(CoilIndex,SpeedRatio,CycRatio,SpeedNum,FanOpMode,CompOp)
      OutletAirTemp = DXCoilOutletTemp(CoilIndex)

    CASE (Coil_CoolingAirToAirVariableSpeed, Coil_CoolingWaterToAirHPVSEquationFit)

      CycRatio   = Par(4)
      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))
      CompOp     = INT(Par(7))
      ReqOutput  = Par(8)
      dummy      = 0.0d0
      RuntimeFrac = 1.0d0
      OnOffAirFlowRatio = 1.0d0

      CALL CalcVarSpeedCoilCooling(CoilIndex,FanOpMode,RuntimeFrac,&
                ReqOutput,dummy,CompOp,CycRatio,OnOffAirFlowRatio, SpeedRatio, SpeedNum)

      OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum)%Temp

    CASE DEFAULT

  END SELECT

  Residuum = Par(2) - OutletAirTemp

  RETURN
END FUNCTION DXCoilVarSpeedResidual

FUNCTION HeatingCoilVarSpeedResidual(SpeedRatio, Par) RESULT (Residuum)
          ! FUNCTION INFORMATION:
          !       AUTHOR         Fred Buhl
          !       DATE WRITTEN   September 2002
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp).
          ! DX Coil output depends on the compressor speed which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls calc routines of  multi Speed or variable Coil to get outlet temperature at the given compressor speed
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils,               ONLY: DXCoilOutletTemp, CalcMultiSpeedDXCoil, CalcMultiSpeedDXCoilHeating
  USE VariableSpeedCoils,    ONLY: CalcVarSpeedCoilHeating
  USE HeatingCoils,          ONLY: CalcMultiStageElectricHeatingCoil, CalcMultiStageGasHeatingCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: SpeedRatio ! compressor speed ratio (1.0 is max, 0.0 is min)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex        ! index of this coil
  INTEGER   :: UnitarySysNum ! index to Unitary System
  REAL(r64) :: OutletAirTemp   ! outlet air temperature [C]
  REAL(r64) :: CycRatio
  INTEGER   :: SpeedNum
  INTEGER   :: FanOpMode
  INTEGER   :: CompOp
  REAL(r64) :: ReqOutput
  REAL(r64) :: RuntimeFrac
  REAL(r64) :: OnOffAirFlowRatio

  CoilIndex = INT(Par(1))
  UnitarySysNum = INT(Par(3))

  SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)

    CASE (CoilDX_MultiSpeedHeating)

      CycRatio   = Par(4)
      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))

      CALL CalcMultiSpeedDXCoilHeating(CoilIndex,SpeedRatio,CycRatio,SpeedNum,FanOpMode)

      OutletAirTemp = DXCoilOutletTemp(CoilIndex)

    CASE (Coil_HeatingAirToAirVariableSpeed, Coil_HeatingWaterToAirHPVSEquationFit)

      CycRatio   = Par(4)
      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))
      CompOp     = INT(Par(7))
      ReqOutput  = Par(8)
      RuntimeFrac = 1.0d0
      OnOffAirFlowRatio = 1.0d0

      CALL CalcVarSpeedCoilHeating(CoilIndex,FanOpMode,RuntimeFrac,&
                ReqOutput,CompOp,CycRatio,OnOffAirFlowRatio, SpeedRatio, SpeedNum)

      OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp

    CASE (Coil_HeatingElectric_MultiStage)

      CycRatio   = Par(4)
      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))

      CALL CalcMultiStageElectricHeatingCoil(CoilIndex,SpeedRatio,CycRatio,SpeedNum,FanOpMode)

      OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp

    CASE (Coil_HeatingGas_MultiStage)

      CycRatio   = Par(4)
      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))

      CALL CalcMultiStageElectricHeatingCoil(CoilIndex,SpeedRatio,CycRatio,SpeedNum,FanOpMode)

      OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp

    CASE DEFAULT

  END SELECT

  Residuum = Par(2) - OutletAirTemp

  RETURN
END FUNCTION HeatingCoilVarSpeedResidual

FUNCTION DXCoilVarSpeedHumRatResidual(SpeedRatio, Par) RESULT (Residuum)
          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   January 2008
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet humrat - actual outlet humrat).
          ! DX Coil output depends on the compressor speed which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls calc routine sof multi speed or variable speed coils to get outlet humidity ratio at the given compressor speed
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils,                   ONLY: DXCoilOutletHumRat, CalcMultiSpeedDXCoil, CalcMultiSpeedDXCoilCooling
  USE VariableSpeedCoils,        ONLY: CalcVarSpeedCoilCooling

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: SpeedRatio ! compressor speed ratio (1.0 is max, 0.0 is min)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet humidity ratio [kg/kg]
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex         ! index of this coil
  INTEGER   :: UnitarySysNum     ! index to Unitary System
  REAL(r64) :: OutletAirHumRat   ! outlet air humidity ratio
  REAL(r64) :: CycRatio
  INTEGER   :: SpeedNum
  INTEGER   :: FanOpMode
  INTEGER   :: CompOp
  REAL(r64) :: ReqOutput
  REAL(r64) :: dummy
  REAL(r64) :: RuntimeFrac
  REAL(r64) :: OnOffAirFlowRatio

  CoilIndex = INT(Par(1))
  UnitarySysNum = INT(Par(3))
  SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

    CASE (CoilDX_CoolingTwoSpeed)

      CALL CalcMultiSpeedDXCoil(CoilIndex,SpeedRatio,1.0d0)
      OutletAirHumRat = DXCoilOutletHumRat(CoilIndex)

    CASE (CoilDX_MultiSpeedCooling)

      CycRatio = Par(4)
      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))
      CompOp     = INT(Par(7))

      CALL CalcMultiSpeedDXCoilCooling(CoilIndex,SpeedRatio,CycRatio,SpeedNum,FanOpMode,CompOp)
      OutletAirHumRat = DXCoilOutletHumRat(CoilIndex)

    CASE (Coil_CoolingAirToAirVariableSpeed, Coil_CoolingWaterToAirHPVSEquationFit)

      CycRatio   = Par(4)
      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))
      CompOp     = INT(Par(7))
      ReqOutput  = Par(8)
      dummy      = 0.0d0
      RuntimeFrac = 1.0d0
      OnOffAirFlowRatio = 1.0d0

      CALL CalcVarSpeedCoilCooling(CoilIndex,FanOpMode,RuntimeFrac,&
                ReqOutput,dummy,CompOp,CycRatio,OnOffAirFlowRatio, SpeedRatio, SpeedNum)

      OutletAirHumRat = Node(UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum)%HumRat

    CASE DEFAULT

  END SELECT

  Residuum = Par(2) - OutletAirHumRat

  RETURN
END FUNCTION DXCoilVarSpeedHumRatResidual

FUNCTION DXCoilCyclingResidual(CycRatio, Par) RESULT (Residuum)
          ! FUNCTION INFORMATION:
          !       AUTHOR         Fred Buhl
          !       DATE WRITTEN   September 2002
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! DX Coil output depends on the cycling ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls multi or variable speed coil to get outlet temperature at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils,             ONLY: DXCoilOutletTemp, CalcMultiSpeedDXCoil, CalcMultiSpeedDXCoilCooling
  USE VariableSpeedCoils,  ONLY: CalcVarSpeedCoilCooling

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: CycRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex       ! index of this coil
  REAL(r64) :: OutletAirTemp   ! outlet air temperature [C]
  REAL(R64) :: SpeedRatio
  INTEGER   :: SpeedNum
  INTEGER   :: FanOpMode
  INTEGER   :: CompOp
  INTEGER   :: UnitarySysNum
  REAL(R64) :: ReqOutput
  REAL(R64) :: dummy
  REAL(r64) :: RuntimeFrac
  REAL(r64) :: OnOffAirFlowRatio

!            Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
!            Par(2) = DesOutTemp
!            Par(3) = UnitarySysNum
!            Par(4) = SpeedRatio
!            Par(5) = UnitarySystem(UnitarySysNum)%CoolingSpeedNum
!            Par(6) = UnitarySystem(UnitarySysNum)%FanOpMode
!            Par(7) = 1.0d0 ! CompOp

  CoilIndex  = INT(Par(1))
  UnitarySysNum = INT(Par(3))

SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

  CASE (CoilDX_CoolingTwoSpeed)

    CALL CalcMultiSpeedDXCoil(CoilIndex,0.0d0,CycRatio)

    OutletAirTemp = DXCoilOutletTemp(CoilIndex)
  CASE (CoilDX_MultiSpeedCooling)

    SpeedRatio = INT(Par(4))
    SpeedNum   = INT(Par(5))
    FanOpMode  = INT(Par(6))
    CompOp     = INT(Par(7))

    CALL CalcMultiSpeedDXCoilCooling(CoilIndex,SpeedRatio,CycRatio,SpeedNum,FanOpMode,CompOp)
    OutletAirTemp = DXCoilOutletTemp(CoilIndex)

  CASE (Coil_CoolingAirToAirVariableSpeed, Coil_CoolingWaterToAirHPVSEquationFit)

      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))
      CompOp     = INT(Par(7))
      ReqOutput  = Par(8)
      dummy      = 0.0d0
      RuntimeFrac = 1.0d0
      OnOffAirFlowRatio = 1.0d0

      CALL CalcVarSpeedCoilCooling(CoilIndex,FanOpMode,RuntimeFrac,&
                ReqOutput,dummy,CompOp,CycRatio,OnOffAirFlowRatio, SpeedRatio, SpeedNum)

      OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum)%Temp

  CASE DEFAULT

END SELECT

  Residuum = Par(2) - OutletAirTemp

  RETURN
END FUNCTION DXCoilCyclingResidual

FUNCTION HeatingCoilVarSpeedCycResidual(CycRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Fred Buhl
          !       DATE WRITTEN   September 2002
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! DX Coil output depends on the cycling ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls multi or variable speed coil to get outlet temperature at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils,               ONLY: DXCoilOutletTemp, CalcMultiSpeedDXCoil, CalcMultiSpeedDXCoilHeating
  USE VariableSpeedCoils,    ONLY: CalcVarSpeedCoilHeating
  USE HeatingCoils,          ONLY: CalcMultiStageElectricHeatingCoil, CalcMultiStageGasHeatingCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: CycRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex       ! index of this coil
  REAL(r64) :: OutletAirTemp   ! outlet air temperature [C]
  REAL(R64) :: SpeedRatio
  INTEGER   :: SpeedNum
  INTEGER   :: FanOpMode
  INTEGER   :: CompOp
  INTEGER   :: UnitarySysNum
  REAL(r64) :: RuntimeFrac
  REAL(r64) :: ReqOutput
  REAL(r64) :: dummy
  REAL(r64) :: OnOffAirFlowRatio

!            Par(1) = REAL(UnitarySystem(UnitarySysNum)%CoolingCoilIndex,r64)
!            Par(2) = DesOutTemp
!            Par(3) = UnitarySysNum
!            Par(4) = SpeedRatio
!            Par(5) = UnitarySystem(UnitarySysNum)%CoolingSpeedNum
!            Par(6) = UnitarySystem(UnitarySysNum)%FanOpMode
!            Par(7) = 1.0d0 ! CompOp

  CoilIndex  = INT(Par(1))
  UnitarySysNum = INT(Par(3))


SELECT CASE(UnitarySystem(UnitarySysNum)%HeatingCoilType_Num)

  CASE (CoilDX_MultiSpeedHeating)

    SpeedRatio = INT(Par(4))
    SpeedNum   = INT(Par(5))
    FanOpMode  = INT(Par(6))
    CompOp     = INT(Par(7))

    CALL CalcMultiSpeedDXCoilHeating(CoilIndex,SpeedRatio,CycRatio,SpeedNum,FanOpMode)
    OutletAirTemp = DXCoilOutletTemp(CoilIndex)

  CASE (Coil_HeatingAirToAirVariableSpeed, Coil_HeatingWaterToAirHPVSEquationFit)

      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))
      CompOp     = INT(Par(7))
      ReqOutput  = Par(8)
      dummy      = 0.0d0
      RuntimeFrac = 1.0d0
      OnOffAirFlowRatio = 1.0d0

      CALL CalcVarSpeedCoilHeating(CoilIndex,FanOpMode,RuntimeFrac,&
                ReqOutput,CompOp,CycRatio,OnOffAirFlowRatio, SpeedRatio, SpeedNum)

      OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp

  CASE (Coil_HeatingElectric_MultiStage)

      SpeedRatio = INT(Par(4))
      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))

      CALL CalcMultiStageElectricHeatingCoil(CoilIndex,SpeedRatio,CycRatio,SpeedNum,FanOpMode)

      OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp

  CASE (Coil_HeatingGas_MultiStage)

      SpeedRatio = INT(Par(4))
      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))

      CALL CalcMultiStageElectricHeatingCoil(CoilIndex,SpeedRatio,CycRatio,SpeedNum,FanOpMode)

      OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp

  CASE DEFAULT


END SELECT

  Residuum = Par(2) - OutletAirTemp

  RETURN
END FUNCTION HeatingCoilVarSpeedCycResidual

FUNCTION DXCoilCyclingHumRatResidual(CycRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Fred Buhl
          !       DATE WRITTEN   September 2002
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! DX Coil output depends on the cycling ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls CalcMultiSpeedDXCoil to get outlet temperature at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils,             ONLY: DXCoilOutletHumRat, CalcMultiSpeedDXCoil, CalcMultiSpeedDXCoilCooling
  USE VariableSpeedCoils,  ONLY: CalcVarSpeedCoilCooling

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: CycRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet humidity ratio [kg/kg]
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex       ! index of this coil
  REAL(r64) :: OutletAirHumRat  ! outlet air humidity ratio [kg/kg]
  REAL(R64) :: SpeedRatio
  INTEGER   :: SpeedNum
  INTEGER   :: FanOpMode
  INTEGER   :: CompOp
  INTEGER   :: UnitarySysNum
  REAL(R64) :: ReqOutput
  REAL(R64) :: dummy
  REAL(r64) :: RuntimeFrac
  REAL(r64) :: OnOffAirFlowRatio

  CoilIndex     = INT(Par(1))
  UnitarySysNum = INT(Par(3))

SELECT CASE(UnitarySystem(UnitarySysNum)%CoolingCoilType_Num)

  CASE (CoilDX_CoolingTwoSpeed)

    CALL CalcMultiSpeedDXCoil(CoilIndex,0.0d0,CycRatio)

    OutletAirHumRat = DXCoilOutletHumRat(CoilIndex)
  CASE (CoilDX_MultiSpeedCooling)

    SpeedRatio = INT(Par(4))
    SpeedNum   = INT(Par(5))
    FanOpMode  = INT(Par(6))
    CompOp     = INT(Par(7))

    CALL CalcMultiSpeedDXCoilCooling(CoilIndex,SpeedRatio,CycRatio,SpeedNum,FanOpMode,CompOp)
    OutletAirHumRat = DXCoilOutletHumRat(CoilIndex)

  CASE (Coil_CoolingAirToAirVariableSpeed, Coil_CoolingWaterToAirHPVSEquationFit)

      SpeedNum   = INT(Par(5))
      FanOpMode  = INT(Par(6))
      CompOp     = INT(Par(7))
      ReqOutput  = Par(8)
      dummy      = 0.0d0
      RuntimeFrac = 1.0d0
      OnOffAirFlowRatio = 1.0d0

      CALL CalcVarSpeedCoilCooling(CoilIndex,FanOpMode,RuntimeFrac,&
                ReqOutput,dummy,CompOp,CycRatio,OnOffAirFlowRatio, SpeedRatio, SpeedNum)

      OutletAirHumRat = Node(UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum)%HumRat

  CASE DEFAULT

END SELECT

  Residuum = Par(2) - OutletAirHumRat

  RETURN
END FUNCTION DXCoilCyclingHumRatResidual

FUNCTION DOE2DXCoilResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   November 2003
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls CalcDOe2DXCoil to get outlet temperature at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils, ONLY: DXCoilOutletTemp, CalcDOe2DXCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet temperature [C]
                                                    ! par(5) = supply air fan operating mode (ContFanCycCoil)
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex       ! index of this coil
  REAL(r64) :: OutletAirTemp   ! outlet air temperature [C]
  INTEGER   :: FanOpMode       ! Supply air fan operating mode

  CoilIndex = INT(Par(1))
  FanOpMode = INT(Par(5))
  CALL CalcDOe2DXCoil(CoilIndex,On,.TRUE., PartLoadRatio,FanOpMode)
  OutletAirTemp = DXCoilOutletTemp(CoilIndex)
  Residuum = Par(2) - OutletAirTemp

  RETURN
END FUNCTION DOE2DXCoilResidual

FUNCTION DOE2DXCoilHumRatResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   January 2008
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet humrat - actual outlet humrat)
          ! DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls CalcDOe2DXCoil to get outlet humidity ratio at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils, ONLY: DXCoilOutletHumRat, CalcDOe2DXCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet humidity ratio [kg/kg]
                                                    ! par(5) = supply air fan operating mode (ContFanCycCoil)
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex       ! index of this coil
  REAL(r64) :: OutletAirHumRat ! outlet air humidity ratio [kg/kg]
  INTEGER   :: FanOpMode       ! Supply air fan operating mode

  CoilIndex = INT(Par(1))
  FanOpMode = INT(Par(5))
  CALL CalcDOe2DXCoil(CoilIndex,On,.TRUE., PartLoadRatio,FanOpMode)
  OutletAirHumRat = DXCoilOutletHumRat(CoilIndex)
  Residuum = Par(2) - OutletAirHumRat

  RETURN
END FUNCTION DOE2DXCoilHumRatResidual

FUNCTION CoolWaterHumRatResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Chandan Sharma, FSEC
          !       DATE WRITTEN   January 2013
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet humrat - actual outlet humrat)
          ! Cool water coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimulateWaterCoilComponents to get outlet temp at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE WaterCoils,     ONLY: SimulateWaterCoilComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = CoolWater coil number
                                                    ! par(2) = desired air outlet humidity ratio [kg/kg]
                                                    ! par(5) = supply air fan operating mode (ContFanCycCoil)
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: UnitarySysNum       ! index of this coil
  REAL(r64) :: OutletAirHumRat        ! outlet air humidity ratio [kg/kg]
  REAL(r64) :: mdot
  LOGICAL   :: FirstHVACIteration


  UnitarySysNum = INT(Par(1))
  IF (Par(2) > 0.0d0) THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF

  mdot = MIN(Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
         UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow * PartLoadRatio)
  Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode)%MassFlowRate = mdot
  CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%CoolingCoilName,FirstHVACIteration, &
                                   UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                   PartLoadRatio = PartLoadRatio)

  OutletAirHumRat = Node(UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum)%HumRat
  Residuum      = Par(3) - OutletAirHumRat

  RETURN
END FUNCTION CoolWaterHumRatResidual

FUNCTION CoolWaterTempResidual(PartLoadRatio, Par) RESULT (Residuum)
          ! FUNCTION INFORMATION:
          !       AUTHOR         Chandan Sharma, FSEC
          !       DATE WRITTEN   January 2013
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! Cool water coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimulateWaterCoilComponents to get outlet temp at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE WaterCoils,     ONLY: SimulateWaterCoilComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = CoolWater coil number
                                                    ! par(2) = desired air outlet humidity ratio [kg/kg]
                                                    ! par(5) = supply air fan operating mode (ContFanCycCoil)
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: UnitarySysNum       ! index of this coil
  REAL(r64) :: OutletAirTemp        ! outlet air humidity ratio [kg/kg]
  REAL(r64) :: mdot
  LOGICAL   :: FirstHVACIteration


  UnitarySysNum = INT(Par(1))
  IF (Par(2) > 0.0d0) THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF

  mdot = MIN(Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
         UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow * PartLoadRatio)
  Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode)%MassFlowRate = mdot
  CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%CoolingCoilName,FirstHVACIteration, &
                                   UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                                   PartLoadRatio = PartLoadRatio)

  OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum)%Temp
  Residuum      = Par(3) - OutletAirTemp

  RETURN
END FUNCTION CoolWaterTempResidual

FUNCTION CoolWatertoAirHPHumRatResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Chandan Sharma, FSEC
          !       DATE WRITTEN   January 2013
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet humrat - actual outlet humrat)
          ! Cool water coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimWatertoAirHP or SimWatertoAirHPSimple to get outlet humidity ratio at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE WatertoAirHeatPumpSimple,  ONLY: SimWatertoAirHPSimple
  USE WatertoAirHeatPump,        ONLY: SimWaterToAirHP

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = CoolWatertoAirHP coil number
                                                    ! par(2) = desired air outlet humidity ratio [kg/kg]
                                                    ! par(5) = supply air fan operating mode (ContFanCycCoil)
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: UnitarySysNum       ! index of this coil
  REAL(r64) :: OutletAirHumRat        ! outlet air humidity ratio [kg/kg]
  REAL(r64) :: ReqOutput
  LOGICAL   :: FirstHVACIteration
  LOGICAL   :: errflag
  REAL(r64)  :: RuntimeFrac        ! heat pump runtime fraction
  REAL(r64)  :: Dummy


  UnitarySysNum = INT(Par(1))
  IF (Par(2) > 0.0d0) THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF
  ReqOutput = Par(4)

  CALL HeatPumpRunFrac(UnitarySysNum,PartLoadRatio,errflag,RuntimeFrac)

  UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadRatio
  UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac   = RuntimeFrac

  Dummy = 0.0d0
  IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHPSimple) THEN
    CALL SimWatertoAirHPSimple(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, ReqOutput, Dummy, &
                               UnitarySystem(UnitarySysNum)%FanOpMode,RuntimeFrac, &
                               UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                               UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                               0, PartLoadRatio, FirstHVACIteration)
  ELSE
    CALL SimWatertoAirHP(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                         UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow,UnitarySystem(UnitarySysNum)%FanOpMode, &
                         FirstHVACIteration,RuntimeFrac,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                         UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                         UnitarySystem(UnitarySysNum)%InitHeatPump, ReqOutput,Dummy,0, PartLoadRatio)
  END IF

  OutletAirHumRat = Node(UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum)%HumRat
  Residuum      = Par(3) - OutletAirHumRat

  RETURN
END FUNCTION CoolWatertoAirHPHumRatResidual

FUNCTION CoolWatertoAirHPTempResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR        Chandan Sharma, FSEC
          !       DATE WRITTEN   January 2013
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! Cool water coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimWatertoAirHP or SimWatertoAirHPSimple to get outlet humidity ratio at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE WatertoAirHeatPumpSimple,  ONLY: SimWatertoAirHPSimple
  USE WatertoAirHeatPump,        ONLY: SimWaterToAirHP

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = CoolWatertoAirHP coil number
                                                    ! par(2) = desired air outlet humidity ratio [kg/kg]
                                                    ! par(5) = supply air fan operating mode (ContFanCycCoil)
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: UnitarySysNum       ! index of this coil
  REAL(r64) :: OutletAirTemp        ! outlet air humidity ratio [kg/kg]
  REAL(r64) :: ReqOutput
  LOGICAL   :: FirstHVACIteration
  LOGICAL   :: errflag
  REAL(r64) :: RuntimeFrac
  REAL(r64) :: Dummy

  UnitarySysNum = INT(Par(1))
  IF (Par(2) > 0.0d0) THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF
  ReqOutput = Par(4)

  CALL HeatPumpRunFrac(UnitarySysNum,PartLoadRatio,errflag,RuntimeFrac)

  IF(RuntimeFrac > 0.0d0 .AND. UnitarySystem(UnitarySysNum)%FanOpMode == CycFanCycCoil)THEN
    OnOffFanPartLoadFraction = PartLoadRatio/RuntimeFrac
  ELSE
    OnOffFanPartLoadFraction = 1
  END IF

  UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadRatio
  UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac   = RuntimeFrac

  Dummy = 0.0d0
  IF (UnitarySystem(UnitarySysNum)%CoolingCoilType_Num == Coil_CoolingWaterToAirHPSimple) THEN
    CALL SimWatertoAirHPSimple(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, ReqOutput, Dummy, &
                               UnitarySystem(UnitarySysNum)%FanOpMode,RuntimeFrac, &
                               UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                               UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                               0, PartLoadRatio, FirstHVACIteration)
  ELSE
    CALL SimWatertoAirHP(Blank, UnitarySystem(UnitarySysNum)%CoolingCoilIndex, &
                         UnitarySystem(UnitarySysNum)%MaxCoolAirMassFlow,UnitarySystem(UnitarySysNum)%FanOpMode, &
                         FirstHVACIteration,RuntimeFrac,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                         UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                         UnitarySystem(UnitarySysNum)%InitHeatPump, ReqOutput,Dummy,0, PartLoadRatio)
  END IF

  OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%CoolCoilOutletNodeNum)%Temp
  Residuum      = Par(3) - OutletAirTemp

  RETURN
END FUNCTION CoolWatertoAirHPTempResidual

FUNCTION HeatWatertoAirHPTempResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Chandan Sharma, FSEC
          !       DATE WRITTEN   January 2013
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! Heat water coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimWatertoAirHP or SimWatertoAirHPSimple to get outlet humidity ratio at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE WatertoAirHeatPumpSimple,  ONLY: SimWatertoAirHPSimple
  USE WatertoAirHeatPump,        ONLY: SimWaterToAirHP

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = HeatWatertoAirHP coil number
                                                    ! par(2) = desired air outlet humidity ratio [kg/kg]
                                                    ! par(5) = supply air fan operating mode (ContFanCycCoil)
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: UnitarySysNum       ! index of this coil
  REAL(r64) :: OutletAirTemp        ! outlet air humidity ratio [kg/kg]
  REAL(r64) :: ReqOutput
  LOGICAL   :: FirstHVACIteration
  LOGICAL   :: errflag
  REAL(r64) :: RuntimeFrac
  REAL(r64) :: Dummy

  UnitarySysNum = INT(Par(1))
  IF (Par(2) > 0.0d0) THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF
  ReqOutput = Par(1)

  CALL HeatPumpRunFrac(UnitarySysNum,PartLoadRatio,errflag,RuntimeFrac)

  IF(RuntimeFrac > 0.0d0 .AND. UnitarySystem(UnitarySysNum)%FanOpMode == CycFanCycCoil)THEN
    OnOffFanPartLoadFraction = PartLoadRatio/RuntimeFrac
  ELSE
    OnOffFanPartLoadFraction = 1
  END IF

  UnitarySystem(UnitarySysNum)%CompPartLoadRatio = PartLoadRatio
  UnitarySystem(UnitarySysNum)%WSHPRuntimeFrac   = RuntimeFrac

  Dummy = 0.0d0
  IF (UnitarySystem(UnitarySysNum)%HeatingCoilType_Num == Coil_HeatingWaterToAirHPSimple) THEN
    CALL SimWatertoAirHPSimple(Blank, UnitarySystem(UnitarySysNum)%HeatingCoilIndex, ReqOutput, Dummy, &
                               UnitarySystem(UnitarySysNum)%FanOpMode,RuntimeFrac, &
                               UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                               UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                               0, PartLoadRatio, FirstHVACIteration)
  ELSE
    CALL SimWatertoAirHP(Blank, UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                         UnitarySystem(UnitarySysNum)%MaxHeatAirMassFlow,UnitarySystem(UnitarySysNum)%FanOpMode, &
                         FirstHVACIteration,RuntimeFrac,UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour, &
                         UnitarySystem(UnitarySysNum)%HPTimeConstant, UnitarySystem(UnitarySysNum)%FanDelayTime, &
                         UnitarySystem(UnitarySysNum)%InitHeatPump, ReqOutput,Dummy,0, PartLoadRatio)
  END IF

  OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp
  Residuum      = Par(3) - OutletAirTemp

  RETURN
END FUNCTION HeatWatertoAirHPTempResidual

SUBROUTINE HeatPumpRunFrac(UnitarySysNum,PLR,errflag,RuntimeFrac)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Kenneth Tang
          !       DATE WRITTEN   Apr 2004
          !       MODIFIED       na
          !       RE-ENGINEERED  na


          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine calculates the PLF based on the PLR. Parameters required are
          ! thermostat cycling rate (Nmax), heat pump time constant (tau), and the fraction
          ! of on-cycle power use (pr)

          ! METHODOLOGY EMPLOYED:
          ! NA


          ! REFERENCES:
          ! (1) Henderson, H. I., K. Rengarajan.1996. A Model to predict the latent capacity
          ! of air conditioners and heat pumps at part-load conditions with constant fan
          ! operation. ASHRAE Transactions 102 (1): 266-274

          ! (2) Henderson, H.I. Jr., Y.J. Huang and Danny Parker. 1999. Residential Equipment
          ! Part Load Curves for Use in DOE-2.  Environmental Energy Technologies Division,
          ! Ernest OrlanDO Lawrence Berkeley National Laboratory.


          ! USE STATEMENTS:


  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine


          ! SUBROUTINE ARGUMENT DEFINITIONS:
  INTEGER,   INTENT(IN)           :: UnitarySysNum       ! UnitarySystem Index Number
  REAL(r64), INTENT(IN)           :: PLR              ! part load ratio
  REAL(r64), INTENT(OUT)          :: RuntimeFrac      ! the required run time fraction to meet part load
  LOGICAL,   INTENT(INOUT)        :: errflag          ! part load factor out of range flag

          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  REAL(r64) :: PartLoadFactor ! Part load factor
  REAL(r64) :: Nmax           ! Maximum cycling rate [cycles/hr]
  REAL(r64) :: tau            ! Heat pump time constant [s]
  REAL(r64) :: pr             ! On-cycle power use fraction [~]
  REAL(r64) :: error          ! Calculation error
  REAL(r64) :: PLF1           ! ith term of part load factor
  REAL(r64) :: PLF2           ! (i+1)th term of part load factor
  REAL(r64) :: A              ! Variable for simplIFy equation
  INTEGER   :: NumIteration   ! Iteration Counter

  Nmax=UnitarySystem(UnitarySysNum)%MaxONOFFCyclesperHour
  tau=UnitarySystem(UnitarySysNum)%HPTimeConstant
  pr=UnitarySystem(UnitarySysNum)%OnCyclePowerFraction

  !Initialize
  errflag = .FALSE.
  error = 1
  NumIteration = 0

  !Initial guess for part load fraction
  PLF1 = 1

  !Calculate PLF using successive substitution until convergence
  !is achieved
  LOOPPLF: DO
    NumIteration=NumIteration + 1

    IF (PLR.EQ.1) THEN
        ! Set part load fraction, PLF1=1.0 IF PLR=1.0 and EXIT loop
        PLF1 = 1
        EXIT LOOPPLF
    END IF

    IF (NumIteration.GT.100)THEN
        ! EXIT loop IF interation exceed 100
        errflag = .TRUE.
        PLF1 = 1
        EXIT LOOPPLF
    END IF

    IF (error.LT.0.00001d0)THEN
        ! EXIT loop IF convergence is achieved
        EXIT LOOPPLF

    ELSE
        ! Calculate PLF
        A = 4.d0 * tau * (Nmax/3600.0d0) * (1 - PLR / PLF1)
        IF (A.LT.1.5d-3) THEN
            ! A safety check to prevent PLF2 = 1 - A * (1 - Exp(-1 / A))
            ! from "float underflow error". Occurs when PLR is very close to 1.0,
            ! small A value, thus Exp(-1/A) = 0
            PLF2 = 1.0d0 - A
        ELSE
            PLF2 = 1.0d0 - A * (1.0d0 - Exp(-1.0d0 / A))
        END IF
        error = ABS((PLF2 - PLF1) / PLF1)
        PLF1 = PLF2
     END IF
  END DO LOOPPLF

  !Adjust PLF for the off cycle power consumption IF
  !on-cycle power use is specified by the user
  IF (pr>0.0d0) THEN
    PartLoadFactor = PLR / ((PLR / PLF1) + (1.0d0 - PLR / PLF1) * pr)
  ELSE
    PartLoadFactor=PLF1
  END IF

  IF (PartLoadFactor <= 0.0d0)THEN
     PartLoadFactor = 0
     RuntimeFrac = 0
     errflag = .TRUE.
  ELSE
     RuntimeFrac = PLR / PartLoadFactor
  END IF

  IF (RuntimeFrac > 1.0d0 ) THEN
     RuntimeFrac = 1.0d0
  END IF

 RETURN

END SUBROUTINE HeatPumpRunFrac

FUNCTION MultiModeDXCoilResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         M. J. Witte, GARD Analytics, Inc.
          !       DATE WRITTEN   February 2005
          !                      (based on DOE2DXCoilResidual by Richard Raustad, FSEC)
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimDXCoilMultiMode to get outlet temperature at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils, ONLY: DXCoilOutletTemp, SimDXCoilMultiMode

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet temperature [C]
                                                    ! par(3) = dehumidification mode (0=normal, 1=enhanced)
                                                    ! par(4) = supply air fan operating mode (ContFanCycCoil)
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex       ! index of this coil
  REAL(r64) :: OutletAirTemp   ! outlet air temperature [C]
  INTEGER   :: DehumidMode     ! dehumidification mode (par3)
  INTEGER   :: FanOpMode       ! supply air fan operating mode

  CoilIndex   = INT(Par(1))
  DehumidMode = INT(Par(3))
  FanOpMode   = INT(Par(4))
  CALL SimDXCoilMultiMode('',On,.FALSE.,PartLoadRatio,DehumidMode,CoilIndex,FanOpMode)
  OutletAirTemp = DXCoilOutletTemp(CoilIndex)
  Residuum = Par(2) - OutletAirTemp

  RETURN
END FUNCTION MultiModeDXCoilResidual

FUNCTION MultiModeDXCoilHumRatResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   January 2008
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet humrat - actual outlet humrat)
          ! DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimDXCoilMultiMode to get outlet humidity ratio at the given cycling ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE DXCoils, ONLY: DXCoilOutletHumRat, SimDXCoilMultiMode

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                    ! par(2) = desired air outlet humidity ratio [kg/kg]
                                                    ! par(3) = dehumidification mode (0=normal, 1=enhanced)
                                                    ! par(4) = supply air fan operating mode (ContFanCycCoil)
    REAL(r64)         :: Residuum ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex       ! index of this coil
  REAL(r64) :: OutletAirHumRat ! outlet air humidity ratio [kg/kg]
  INTEGER   :: DehumidMode     ! dehumidification mode (par3)
  INTEGER   :: FanOpMode       ! supply air fan operating mode

  CoilIndex   = INT(Par(1))
  DehumidMode = INT(Par(3))
  FanOpMode   = INT(Par(4))
  CALL SimDXCoilMultiMode('',On,.FALSE.,PartLoadRatio,DehumidMode,CoilIndex,FanOpMode)
  OutletAirHumRat = DXCoilOutletHumRat(CoilIndex)
  Residuum = Par(2) - OutletAirHumRat

  RETURN
END FUNCTION MultiModeDXCoilHumRatResidual

FUNCTION HXAssistedCoolCoilTempResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   November 2003
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          !  Calculates residual function (desired outlet temp - actual outlet temp)
          !  DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          !  Calls CalcHXAssistedCoolingCoil to get outlet temperature at the given part load ratio
          !  and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE HVACHXAssistedCoolingCoil, ONLY: HXAssistedCoilOutletTemp, CalcHXAssistedCoolingCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  REAL(r64), INTENT(IN)     :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
  REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                  ! par(2) = desired air outlet temperature [C]
                                                  ! par(3) = FirstHVACIteration logical converted to numeric (1=TRUE,0=FALSE)
                                                  ! par(4) = HX control (On/Off)
                                                  ! par(5) = supply air fan operating mode (ContFanCycCoil)
  REAL(r64)         :: Residuum  ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          !  na

          ! INTERFACE BLOCK SPECIFICATIONS
          !  na

          ! DERIVED TYPE DEFINITIONS
          !  na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex          ! index of this coil
  REAL(r64) :: OutletAirTemp      ! outlet air temperature [C]
  LOGICAL   :: FirstHVACIteration ! FirstHVACIteration flag
  LOGICAL   :: HXUnitOn           ! flag to enable heat exchanger heat recovery
  INTEGER   :: FanOpMode          ! Supply air fan operating mode
  INTEGER   :: UnitarySysNum      ! index to unitary system

  CoilIndex = INT(Par(1))
  ! FirstHVACIteration is a logical, Par is REAL(r64), so make 1=TRUE and 0=FALSE
  IF(Par(3) .EQ. 1.0d0)THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF
  IF(Par(4) .EQ. 1.0d0)THEN
    HXUnitOn = .TRUE.
  ELSE
    HXUnitOn = .FALSE.
  END IF
  FanOpMode = INT(Par(5))
  UnitarySysNum = INT(Par(6))
  IF(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode .GT. 0)THEN
    Node(UnitarySystem(UnitarySysNum)%CoolCoilFluidInletNode)%MassFlowRate = &
      UnitarySystem(UnitarySysNum)%MaxCoolCoilFluidFlow * PartLoadRatio
  END IF
  CALL CalcHXAssistedCoolingCoil(CoilIndex,FirstHVACIteration,On,PartLoadRatio, HXUnitOn, FanOpMode)
  OutletAirTemp = HXAssistedCoilOutletTemp(CoilIndex)
  Residuum = Par(2) - OutletAirTemp
  RETURN

END FUNCTION HXAssistedCoolCoilTempResidual

FUNCTION HXAssistedCoolCoilHRResidual(PartLoadRatio, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad, FSEC
          !       DATE WRITTEN   January 2008
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          !  Calculates residual function (desired outlet humrat - actual outlet humrat)
          !  DX Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          !  Calls CalcHXAssistedCoolingCoil to get outlet humidity ratio at the given part load ratio
          !  and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE HVACHXAssistedCoolingCoil, ONLY: HXAssistedCoilOutletHumRat, CalcHXAssistedCoolingCoil

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  REAL(r64), INTENT(IN)     :: PartLoadRatio ! compressor cycling ratio (1.0 is continuous, 0.0 is off)
  REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! par(1) = DX coil number
                                                  ! par(2) = desired air outlet humidity ratio [kg/kg]
                                                  ! par(3) = FirstHVACIteration logical converted to numeric (1=TRUE,0=FALSE)
                                                  ! par(4) = HX control (On/Off)
                                                  ! par(5) = supply air fan operating mode (ContFanCycCoil)
  REAL(r64)         :: Residuum  ! residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          !  na

          ! INTERFACE BLOCK SPECIFICATIONS
          !  na

          ! DERIVED TYPE DEFINITIONS
          !  na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER   :: CoilIndex          ! index of this coil
  REAL(r64) :: OutletAirHumRat    ! outlet air humidity ratio [kg/kg]
  LOGICAL   :: FirstHVACIteration ! FirstHVACIteration flag
  LOGICAL   :: HXUnitOn           ! flag to enable heat exchanger heat recovery
  INTEGER   :: FanOpMode          ! Supply air fan operating mode

  CoilIndex = INT(Par(1))
  ! FirstHVACIteration is a logical, Par is REAL(r64), so make 1=TRUE and 0=FALSE
  IF(Par(3) .EQ. 1.0d0)THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF
  IF(Par(4) .EQ. 1.0d0)THEN
    HXUnitOn = .TRUE.
  ELSE
    HXUnitOn = .FALSE.
  END IF
  FanOpMode = INT(Par(5))
  CALL CalcHXAssistedCoolingCoil(CoilIndex,FirstHVACIteration,On,PartLoadRatio, HXUnitOn, FanOpMode, &
                                 EconomizerFlag=EconomizerFlag)
  OutletAirHumRat = HXAssistedCoilOutletHumRat(CoilIndex)
  Residuum = Par(2) - OutletAirHumRat
  RETURN

END FUNCTION HXAssistedCoolCoilHRResidual

FUNCTION GasElecHeatingCoilResidual(PartLoadFrac, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Chandan Sharma, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! hot water Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimulateHeatingCoilComponents to get outlet temperature at the given part load ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE HeatingCoils,    ONLY: SimulateHeatingCoilComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadFrac               ! Compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! Par(1) = DX coil number
                                                    ! Par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum                   ! Residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  REAL(r64)    :: OutletAirTemp    ! Outlet air temperature [C]
  INTEGER      :: UnitarySysNum
  INTEGER      :: FanOpMode              =0   ! Fan operating mode (see parameter above)
  LOGICAL      :: FirstHVACIteration
  LOGICAL      :: SuppHeatingCoilFlag

  UnitarySysNum = INT(Par(1))
  IF (Par(2) > 0.0d0) THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF
  IF (Par(4) > 0.0d0) THEN
    SuppHeatingCoilFlag = .TRUE.
  ELSE
    SuppHeatingCoilFlag = .FALSE.
  END IF
  FanOpMode = Par(4)
  IF (.NOT. SuppHeatingCoilFlag) THEN
    CALL SimulateHeatingCoilComponents(UnitarySystem(UnitarySysNum)%HeatingCoilName,FirstHVACIteration, &
                                       CompIndex=UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                       FanOpMode=FanOpMode, &
                                       PartLoadRatio = PartLoadFrac)
    OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp
  ELSE
    CALL SimulateHeatingCoilComponents(UnitarySystem(UnitarySysNum)%SuppHeatCoilName,FirstHVACIteration, &
                                       CompIndex=UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
                                       FanOpMode=FanOpMode, &
                                       PartLoadRatio = PartLoadFrac, SuppHeat=.TRUE.)
    OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode)%Temp
  END IF
  Residuum      = Par(3) - OutletAirTemp

  RETURN
END FUNCTION GasElecHeatingCoilResidual

FUNCTION HotWaterHeatingCoilResidual(PartLoadFrac, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Chandan Sharma, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! hot water Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimulateWaterCoilComponents to get outlet temperature at the given part load ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE WaterCoils,       ONLY: SimulateWaterCoilComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadFrac               ! Compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! Par(1) = DX coil number
                                                    ! Par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum                   ! Residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  REAL(r64)    :: OutletAirTemp    ! Outlet air temperature [C]
  REAL(r64)    :: mdot             ! water-side flow rate of HW coil [kg/s]
  REAL(r64)    :: QActual          ! heating capacity of HW coil [W]
  INTEGER      :: UnitarySysNum    ! index to unitary system
  LOGICAL      :: FirstHVACIteration ! iteration flag
  LOGICAL      :: SuppHeatingCoilFlag ! TRUE if supplemental heating coil
  LOGICAL      :: LoadBased        ! TRUE if controlling to load, else control to temperature

  UnitarySysNum = INT(Par(1))
  IF (Par(2) > 0.0d0) THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF
  IF (Par(4) > 0.0d0) THEN
    SuppHeatingCoilFlag = .TRUE.
  ELSE
    SuppHeatingCoilFlag = .FALSE.
  END IF
  IF(Par(5) > 0.0d0)THEN
    LoadBased = .TRUE.
  ELSE
    LoadBased = .FALSE.
  END IF
  QActual = 0.0d0
  IF (.NOT. SuppHeatingCoilFlag) THEN
    mdot = MIN(Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
           UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow * PartLoadFrac)
    Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode)%MassFlowRate = mdot
    CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%HeatingCoilName,FirstHVACIteration, &
                                     UnitarySystem(UnitarySysNum)%HeatingCoilIndex,QActual=QActual, &
                                     FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode,PartLoadRatio = PartLoadFrac)
    OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp
  ELSE
    mdot = MIN(Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
           UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow * PartLoadFrac)
    Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode)%MassFlowRate = mdot
    CALL SimulateWaterCoilComponents(UnitarySystem(UnitarySysNum)%SuppHeatCoilName,FirstHVACIteration, &
                                     UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex,QActual=QActual, &
                                     FanOpMode=UnitarySystem(UnitarySysNum)%FanOpMode,PartLoadRatio = PartLoadFrac)
    OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%SuppCoilAirOutletNode)%Temp
  END IF
  IF(LoadBased)THEN
    Residuum      = Par(3) - QActual
  ELSE
    Residuum      = Par(3) - OutletAirTemp
  END IF

  RETURN
END FUNCTION HotWaterHeatingCoilResidual

FUNCTION SteamHeatingCoilResidual(PartLoadFrac, Par) RESULT (Residuum)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Chandan Sharma, FSEC
          !       DATE WRITTEN   February 2013
          !       MODIFIED
          !       RE-ENGINEERED

          ! PURPOSE OF THIS FUNCTION:
          ! Calculates residual function (desired outlet temp - actual outlet temp)
          ! hot Steam Coil output depends on the part load ratio which is being varied to zero the residual.

          ! METHODOLOGY EMPLOYED:
          ! Calls SimulateSteamCoilComponents to get outlet temperature at the given part load ratio
          ! and calculates the residual as defined above

          ! REFERENCES:

          ! USE STATEMENTS:
  USE SteamCoils,       ONLY: SimulateSteamCoilComponents

  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
    REAL(r64), INTENT(IN)  :: PartLoadFrac               ! Compressor cycling ratio (1.0 is continuous, 0.0 is off)
    REAL(r64), INTENT(IN), DIMENSION(:), OPTIONAL :: Par ! Par(1) = DX coil number
                                                    ! Par(2) = desired air outlet temperature [C]
    REAL(r64)         :: Residuum                   ! Residual to be minimized to zero

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na

          ! DERIVED TYPE DEFINITIONS
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  REAL(r64)    :: OutletAirTemp    ! Outlet air temperature [C]
  REAL(r64)    :: mdot
  INTEGER      :: UnitarySysNum
  LOGICAL      :: FirstHVACIteration
  LOGICAL      :: SuppHeatingCoilFlag

  UnitarySysNum = INT(Par(1))
  IF (Par(2) > 0.0d0) THEN
    FirstHVACIteration = .TRUE.
  ELSE
    FirstHVACIteration = .FALSE.
  END IF
  IF (Par(4) > 0.0d0) THEN
    SuppHeatingCoilFlag = .TRUE.
  ELSE
    SuppHeatingCoilFlag = .FALSE.
  END IF

  IF (.NOT. SuppHeatingCoilFlag) THEN
    mdot = MIN(Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
           UnitarySystem(UnitarySysNum)%MaxHeatCoilFluidFlow * PartLoadFrac)
    Node(UnitarySystem(UnitarySysNum)%HeatCoilFluidInletNode)%MassFlowRate = mdot
    CALL SimulateSteamCoilComponents(UnitarySystem(UnitarySysNum)%HeatingCoilName, FirstHVACIteration, &
                                     1.0d0, &
                                     UnitarySystem(UnitarySysNum)%HeatingCoilIndex, &
                                     FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode, &
                                     PartLoadRatio = PartLoadFrac)
  ELSE
    mdot = MIN(Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidOutletNodeNum)%MassFlowRateMaxAvail, &
           UnitarySystem(UnitarySysNum)%MaxSuppCoilFluidFlow * PartLoadFrac)
    Node(UnitarySystem(UnitarySysNum)%SuppCoilFluidInletNode)%MassFlowRate = mdot
    CALL SimulateSteamCoilComponents(UnitarySystem(UnitarySysNum)%SuppHeatCoilName, FirstHVACIteration, &
                                     1.0d0, &
                                     UnitarySystem(UnitarySysNum)%SuppHeatCoilIndex, &
                                     FanOpMode = UnitarySystem(UnitarySysNum)%FanOpMode, &
                                     PartLoadRatio = PartLoadFrac)
  END IF
  OutletAirTemp = Node(UnitarySystem(UnitarySysNum)%HeatCoilOutletNodeNum)%Temp
  Residuum      = Par(3) - OutletAirTemp

  RETURN
END FUNCTION SteamHeatingCoilResidual

SUBROUTINE FrostControlSetPointLimit(UnitarySysNum,TempSetPoint,HumRatSetPoint,BaroPress,TfrostControl,ControlMode)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Bereket Nigusse, FSEC
          !       DATE WRITTEN   January 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na
          !
          ! PURPOSE OF THIS SUBROUTINE:
          ! Controls the forst formation condition based on user specified minimum DX coil outlet
          ! air temperature. Resets the cooling setpoint based on the user specified limiting
          ! temperature for frost control.
          !
          ! METHODOLOGY EMPLOYED:
          ! Based on FrostControlSetPointLimit by Bereket Nigusse in HVACDXSystem
          !
          ! REFERENCES:
          !  na
          ! USE STATEMENTS:
  USE Psychrometrics,     ONLY: PsyWFnTdpPb
          !
  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine
          !
          ! SUBROUTINE ARGUMENT DEFINITIONS:
    INTEGER, INTENT(IN)       :: UnitarySysNum           ! dx cooling coil system index
    REAL(r64), INTENT(INOUT)  :: TempSetPoint          ! temperature setpoint of the sensor node
    REAL(r64), INTENT(INOUT)  :: HumRatSetPoint        ! humidity ratio setpoint of the sensor node
    REAL(r64), INTENT(IN)     :: BaroPress             ! baromtric pressure, Pa [N/m^2]
    REAL(r64), INTENT(IN)     :: TfrostControl         ! minimum temperature limit for forst control
    INTEGER, INTENT(IN)       :: ControlMode           ! temperature or humidity control mode

          ! SUBROUTINE PARAMETER DEFINITIONS:
    INTEGER, PARAMETER        :: RunOnSensible = 1     ! identifier for temperature (sensible load) control
    INTEGER, PARAMETER        :: RunOnLatent = 2       ! identifier for humidity (latent load) control

          ! INTERFACE BLOCK SPECIFICATIONS
          ! na
          !
          ! DERIVED TYPE DEFINITIONS
          ! na
          !
          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  REAL(r64)                   :: HumRatioSat     ! saturation humidity ratio at forst control temperature
  REAL(r64)                   :: AirMassFlow     ! air masss flow rate through the DX coil
  !
  AirMassFlow = Node(UnitarySystem(UnitarySysNum)%CoolCoilInletNodeNum)%MassFlowRate
  IF (ControlMode == RunOnSensible .AND. AirMassFlow > MinAirMassFlow .AND. &
      TempSetPoint .LT. Node(UnitarySystem(UnitarySysNum)%CoolCoilInletNodeNum)%Temp) THEN
    IF (TempSetPoint .lt. TfrostControl) THEN
        TempSetPoint = TfrostControl
        UnitarySystem(UnitarySysNum)%FrostControlStatus = 1
    END IF
  ELSEIF(ControlMode == RunOnLatent .AND. AirMassFlow > MinAirMassFlow .AND. &
         HumRatSetPoint .LT. Node(UnitarySystem(UnitarySysNum)%CoolCoilInletNodeNum)%HumRat) THEN
    HumRatioSat = PsyWFnTdpPb(TfrostControl,BaroPress,'FrostControlSetPointLimit')
    IF (HumRatioSat .gt. HumRatSetPoint) THEN
        HumRatSetPoint = HumRatioSat
        UnitarySystem(UnitarySysNum)%FrostControlStatus = 2
    END IF
  ELSE
    UnitarySystem(UnitarySysNum)%FrostControlStatus = 0
  END IF
  RETURN
END SUBROUTINE FrostControlSetPointLimit

SUBROUTINE CheckUnitarySysCoilInOASysExists(UnitarySysName)

          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Chandan Sharma
          !       DATE WRITTEN   April 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na
          !
          ! PURPOSE OF THIS SUBROUTINE:
          ! After making sure get input is done, checks if the Coil System DX coil is in the
          ! OA System.  IF exists then the DX cooling coil is 100% DOAS DX coil.
          !
          ! METHODOLOGY EMPLOYED:
          ! Based on CheckDXCoolingCoilInOASysExists by Bereket Nigusse in HVACDXSystem
          !
          ! REFERENCES:
          ! na
          !
          ! USE STATEMENTS:
  USE InputProcessor, ONLY: FindItemInList
  USE DXCoils,        ONLY: SetDXCoilTypeData

  IMPLICIT NONE ! Enforce explicit typing of all variables in this routine

          ! SUBROUTINE ARGUMENT DEFINITIONS:
  CHARACTER(len=MaxNameLength), INTENT(IN) :: UnitarySysName

          ! SUBROUTINE PARAMETER DEFINITIONS:
  CHARACTER(len=*), PARAMETER :: RoutineName='CheckUnitarySysCoilInOASysExists: ' ! include trailing blank space

          ! INTERFACE BLOCK SPECIFICATIONS:
          ! na

          ! DERIVED TYPE DEFINITIONS:
          ! na

          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER                       :: UnitarySysNum

  IF (GetInputFlag) THEN
    CALL GetUnitarySystemInput
    GetInputFlag=.false.
  END IF

  UnitarySysNum=0
  IF (NumUnitarySystem > 0) THEN
     UnitarySysNum=FindItemInList(UnitarySysName,UnitarySystem%Name,NumUnitarySystem)
     IF (UnitarySysNum > 0)THEN
       IF(UnitarySystem(UnitarySysNum)%ISHundredPercentDOASDXCoil) THEN
         CALL SetDXCoilTypeData(UnitarySystem(UnitarySysNum)%CoolingCoilName)
       END IF
     ELSE
       CALL ShowSevereError(TRIM(RoutineName)//'System not found = AirloopHVAC:UnitarySystem "'//TRIM(UnitarySysName)//'"')
     END IF
  ELSE
    CALL ShowSevereError(TRIM(RoutineName)//'System not found = AirloopHVAC:UnitarySystem "'//TRIM(UnitarySysName)//'"')
  END IF


  RETURN

END SUBROUTINE CheckUnitarySysCoilInOASysExists

SUBROUTINE GetUnitarySystemOAHeatCoolCoil(UnitarySystemName, OACoolingCoil, OAHeatingCoil)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Chandan Sharma
          !       DATE WRITTEN   April 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS FUNCTION:
          ! Determined weather Unitary system in OA stream has heating or cooling coils

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE InputProcessor,   ONLY: SameString

  IMPLICIT NONE ! Enforce explicit typing of all variables in this routine

          ! FUNCTION ARGUMENT DEFINITIONS:
  CHARACTER(len=*), INTENT(IN)         :: UnitarySystemName  ! Name of Unitary System object
  LOGICAL,   INTENT(INOUT),   OPTIONAL :: OACoolingCoil      ! Cooling coil in OA stream
  LOGICAL,   INTENT(INOUT),   OPTIONAL :: OAHeatingCoil      ! Heating coil in OA stream

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS:
          ! na

          ! DERIVED TYPE DEFINITIONS:
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER :: UnitarySysNum

  IF (GetInputFlag) THEN             !First time subroutine has been entered
    CALL GetUnitarySystemInput
    GetInputFlag=.false.
  END IF

  DO UnitarySysNum = 1,  NumUnitarySystem
    IF(SameString(UnitarySystemName,UnitarySystem(UnitarySysNum)%Name))THEN
      IF (UnitarySystem(UnitarySysNum)%CoolCoilExists) THEN
        OACoolingCoil = .TRUE.
      END IF
      IF (UnitarySystem(UnitarySysNum)%HeatCoilExists .OR. &
          UnitarySystem(UnitarySysNum)%SuppCoilExists) THEN
        OAHeatingCoil = .TRUE.
      END IF
    END IF
  END DO

  RETURN

END SUBROUTINE GetUnitarySystemOAHeatCoolCoil

FUNCTION GetUnitarySystemDXCoolingCoilIndex(UnitarySystemName)

          ! FUNCTION INFORMATION:
          !       AUTHOR         Richard Raustad
          !       DATE WRITTEN   July 2013
          !       MODIFIED       na
          !       RE-ENGINEERED  na

          ! PURPOSE OF THIS FUNCTION:
          ! Find the DX cooling coil in this Unitary System

          ! METHODOLOGY EMPLOYED:
          ! na

          ! REFERENCES:
          ! na

          ! USE STATEMENTS:
  USE InputProcessor,   ONLY: SameString

  IMPLICIT NONE ! Enforce explicit typing of all variables in this routine

          ! FUNCTION ARGUMENT DEFINITIONS:
  CHARACTER(len=*), INTENT(IN)         :: UnitarySystemName  ! Name of Unitary System object

          ! FUNCTION PARAMETER DEFINITIONS:
          ! na

          ! INTERFACE BLOCK SPECIFICATIONS:
          ! na

          ! DERIVED TYPE DEFINITIONS:
          ! na

          ! FUNCTION LOCAL VARIABLE DECLARATIONS:
  INTEGER :: UnitarySysNum
  INTEGER :: GetUnitarySystemDXCoolingCoilIndex

  IF (GetInputFlag) THEN             !First time subroutine has been entered
    CALL GetUnitarySystemInput
    GetInputFlag=.false.
  END IF

  GetUnitarySystemDXCoolingCoilIndex = 0
  DO UnitarySysNum = 1,  NumUnitarySystem
    IF(SameString(UnitarySystemName,UnitarySystem(UnitarySysNum)%Name))THEN
      IF (UnitarySystem(UnitarySysNum)%CoolCoilExists) THEN
        GetUnitarySystemDXCoolingCoilIndex = UnitarySystem(UnitarySysNum)%CoolingCoilIndex
      END IF
    END IF
  END DO

  RETURN

END FUNCTION GetUnitarySystemDXCoolingCoilIndex

END MODULE HVACUnitarySystem

! *****************************************************************************
!
!     NOTICE
!
!     Copyright © 1996-2013 The Board of Trustees of the University of Illinois
!     and The Regents of the University of CalIFornia through Ernest OrlanDO Lawrence
!     Berkeley National Laboratory.  All rights reserved.
!
!     Portions of the EnergyPlus software package have been developed and copyrighted
!     by other individuals, companies and institutions.  These portions have been
!     incorporated into the EnergyPlus software package under license.   For a complete
!     list of contributors, see "Notice" located in EnergyPlus.f90.
!
!     NOTICE: The U.S. Government is granted for itself and others acting on its
!     behalf a paid-up, nonexclusive, irrevocable, worldwide license in this data to
!     reproduce, prepare derivative works, and perform publicly and display publicly.
!     Beginning five (5) years after permission to assert copyright is granted,
!     subject to two possible five year renewals, the U.S. Government is granted for
!     itself and others acting on its behalf a paid-up, non-exclusive, irrevocable
!     worldwide license in this data to reproduce, prepare derivative works,
!     distribute copies to the public, perform publicly and display publicly, and to
!     permit others to DO so.
!
!     TRADEMARKS: EnergyPlus is a trademark of the US Department of Energy.
!

AirflowNetworkBalanceManager.f90 AirflowNetworkSolver.f90 BaseboardRadiator.f90 BaseboardRadiatorElectric.f90 BaseboardRadiatorSteam.f90 BaseboardRadiatorWater.f90 BranchInputManager.f90 BranchNodeConnections.f90 ConductionTransferFunctionCalc.f90 CoolTower.f90 CostEstimateManager.f90 CurveManager.f90 CVFOnlyRoutines.f90 DataAirflowNetwork.f90 DataAirLoop.f90 DataAirSystems.f90 DataBranchAirLoopPlant.f90 DataBranchNodeConnections.f90 DataBSDFWindow.f90 DataComplexFenestration.f90 DataContaminantBalance.f90 DataConvergParams.f90 DataConversions.f90 DataCostEstimate.f90 DataDaylighting.f90 DataDaylightingDevices.f90 Datadefineequip.f90 DataDElight.f90 DataEnvironment.f90 DataEquivalentLayerWindow.f90 DataErrorTracking.f90 DataGenerators.f90 DataGlobalConstants.f90 DataGlobals.f90 DataHeatBalance.f90 DataHeatBalFanSys.f90 DataHeatBalSurface.f90 DataHVACControllers.f90 DataHVACGlobals.f90 DataInterfaces.f90 DataIPShortCuts.f90 DataLoopNode.f90 DataMoistureBalance.f90 DataMoistureBalanceEMPD.f90 DataOutputs.f90 DataPhotovoltaics.f90 DataPlant.f90 DataPlantPipingSystems.f90 DataPrecisionGlobals.f90 DataReportingFlags.f90 DataRoomAir.f90 DataRootFinder.f90 DataRuntimeLanguage.f90 DataShadowingCombinations.f90 DataSizing.f90 DataStringGlobals.f90 DataSurfaceColors.f90 DataSurfaceLists.f90 DataSurfaces.f90 DataSystemVariables.f90 DataTimings.f90 DataUCSDSharedData.f90 DataVectorTypes.f90 DataViewFactorInformation.f90 DataWater.f90 DataZoneControls.f90 DataZoneEnergyDemands.f90 DataZoneEquipment.f90 DaylightingDevices.f90 DaylightingManager.f90 DElightManagerF.f90 DElightManagerF_NO.f90 DemandManager.f90 DesiccantDehumidifiers.f90 DirectAir.f90 DisplayRoutines.f90 DXCoil.f90 EarthTube.f90 EconomicLifeCycleCost.f90 EconomicTariff.f90 EcoRoof.f90 ElectricPowerGenerators.f90 ElectricPowerManager.f90 EMSManager.f90 EnergyPlus.f90 ExteriorEnergyUseManager.f90 ExternalInterface_NO.f90 FanCoilUnits.f90 FaultsManager.f90 FluidProperties.f90 General.f90 GeneralRoutines.f90 GlobalNames.f90 HeatBalanceAirManager.f90 HeatBalanceConvectionCoeffs.f90 HeatBalanceHAMTManager.f90 HeatBalanceInternalHeatGains.f90 HeatBalanceIntRadExchange.f90 HeatBalanceManager.f90 HeatBalanceMovableInsulation.f90 HeatBalanceSurfaceManager.f90 HeatBalFiniteDifferenceManager.f90 HeatRecovery.f90 Humidifiers.f90 HVACControllers.f90 HVACCooledBeam.f90 HVACDualDuctSystem.f90 HVACDuct.f90 HVACDXSystem.f90 HVACEvapComponent.f90 HVACFanComponent.f90 HVACFurnace.f90 HVACHeatingCoils.f90 HVACHXAssistedCoolingCoil.f90 HVACInterfaceManager.f90 HVACManager.f90 HVACMixerComponent.f90 HVACMultiSpeedHeatPump.f90 HVACSingleDuctInduc.f90 HVACSingleDuctSystem.f90 HVACSplitterComponent.f90 HVACStandAloneERV.f90 HVACSteamCoilComponent.f90 HVACTranspiredCollector.f90 HVACUnitaryBypassVAV.f90 HVACUnitarySystem.f90 HVACVariableRefrigerantFlow.f90 HVACWaterCoilComponent.f90 HVACWatertoAir.f90 HVACWatertoAirMultiSpeedHP.f90 InputProcessor.f90 MatrixDataManager.f90 MixedAir.f90 MoistureBalanceEMPDManager.f90 NodeInputManager.f90 NonZoneEquipmentManager.f90 OutAirNodeManager.f90 OutdoorAirUnit.f90 OutputProcessor.f90 OutputReportPredefined.f90 OutputReports.f90 OutputReportTabular.f90 PackagedTerminalHeatPump.f90 PackagedThermalStorageCoil.f90 Photovoltaics.f90 PhotovoltaicThermalCollectors.f90 PlantAbsorptionChillers.f90 PlantBoilers.f90 PlantBoilersSteam.f90 PlantCentralGSHP.f90 PlantChillers.f90 PlantCondLoopOperation.f90 PlantCondLoopTowers.f90 PlantEIRChillers.f90 PlantEvapFluidCoolers.f90 PlantExhaustAbsorptionChiller.f90 PlantFluidCoolers.f90 PlantGasAbsorptionChiller.f90 PlantGroundHeatExchangers.f90 PlantHeatExchanger.f90 PlantIceThermalStorage.f90 PlantLoadProfile.f90 PlantLoopEquipment.f90 PlantLoopSolver.f90 PlantManager.f90 PlantOutsideEnergySources.f90 PlantPipeHeatTransfer.f90 PlantPipes.f90 PlantPipingSystemManager.f90 PlantPondGroundHeatExchanger.f90 PlantPressureSystem.f90 PlantPumps.f90 PlantSolarCollectors.f90 PlantSurfaceGroundHeatExchanger.f90 PlantUtilities.f90 PlantValves.f90 PlantWaterSources.f90 PlantWaterThermalTank.f90 PlantWatertoWaterGSHP.f90 PlantWaterUse.f90 PollutionAnalysisModule.f90 PoweredInductionUnits.f90 PsychRoutines.f90 Purchasedairmanager.f90 RadiantSystemHighTemp.f90 RadiantSystemLowTemp.f90 RefrigeratedCase.f90 ReportSizingManager.f90 ReturnAirPath.f90 RoomAirManager.f90 RoomAirModelCrossVent.f90 RoomAirModelDisplacementVent.f90 RoomAirModelMundt.f90 RoomAirModelUFAD.f90 RoomAirModelUserTempPattern.f90 RootFinder.f90 RuntimeLanguageProcessor.f90 ScheduleManager.f90 SetPointManager.f90 SimAirServingZones.f90 SimulationManager.f90 SizingManager.f90 SolarReflectionManager.f90 SolarShading.f90 SortAndStringUtilities.f90 sqlite3.c SQLiteCRoutines.c SQLiteFortranRoutines.f90 SQLiteFortranRoutines_NO.f90 StandardRatings.f90 SurfaceGeometry.f90 SystemAvailabilityManager.f90 SystemReports.f90 TarcogComplexFenestration.f90 ThermalChimney.f90 ThermalComfort.f90 UnitHeater.f90 UnitVentilator.f90 UserDefinedComponents.f90 UtilityRoutines.f90 VectorUtilities.f90 VentilatedSlab.f90 WaterManager.f90 WeatherManager.f90 WindowAC.f90 WindowComplexManager.f90 WindowEquivalentLayer.f90 WindowManager.f90 WindTurbine.f90 Zoneairloopequipmentmanager.f90 ZoneContaminantPredictorCorrector.f90 ZoneDehumidifier.f90 Zoneequipmentmanager.f90 ZonePlenumComponent.f90 ZoneTempPredictorCorrector.f90