Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
integer, | intent(in) | :: | SetPtMgrNum |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE CalcSZOneStageHeatingSetPt(SetPtMgrNum)
! SUBROUTINE INFORMATION:
! AUTHOR B. Griffith
! DATE WRITTEN August 2013
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! calculate the setpoint for staged on/off control
! METHODOLOGY EMPLOYED:
! Evaluate stage in zone energy demand structure and choose setpoint accordingly
! REFERENCES:
! na
! USE STATEMENTS:
USE DataZoneEnergyDemands, ONLY: ZoneSysEnergyDemand
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
INTEGER, INTENT (IN) :: SetPtMgrNum ! number of the current setpoint manager being simulated
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
IF (ZoneSysEnergyDemand(SZOneStageHeatingSetPtMgr(SetPtMgrNum)%ControlZoneNum)%StageNum <= 0) THEN
SZOneStageHeatingSetPtMgr(SetPtMgrNum)%SetPt = SZOneStageHeatingSetPtMgr(SetPtMgrNum)%HeatingOffTemp
ELSE ! positive so a heating stage is set
SZOneStageHeatingSetPtMgr(SetPtMgrNum)%SetPt = SZOneStageHeatingSetPtMgr(SetPtMgrNum)%HeatingOnTemp
ENDIF
RETURN