Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
INTEGER FUNCTION GetFanCoilMixedAirNode(FanCoilNum)
! FUNCTION INFORMATION:
! AUTHOR B Griffith
! DATE WRITTEN Dec 2006
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS FUNCTION:
! lookup function for mixer's return node
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
USE MixedAir, ONLY: GetOAMixerMixedNodeNumber
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! FUNCTION ARGUMENT DEFINITIONS:
INTEGER, INTENT (IN) :: FanCoilNum !
! FUNCTION PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! FUNCTION LOCAL VARIABLE DECLARATIONS:
! na
IF (GetFanCoilInputFlag) THEN
CALL GetFanCoilUnits
GetFanCoilInputFlag = .FALSE.
END IF
GetFanCoilMixedAirNode = 0
IF (FanCoilNum > 0 .and. FanCoilNum <= NumFanCoils) THEN
IF (FanCoil(FanCoilNum)%OAMixIndex > 0) THEN
GetFanCoilMixedAirNode = GetOAMixerMixedNodeNumber(FanCoil(FanCoilNum)%OAMixIndex)
ELSE
GetFanCoilMixedAirNode = 0
END IF
ENDIF
RETURN
END FUNCTION GetFanCoilMixedAirNode