Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
integer, | intent(in) | :: | CoilNum |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE UpdateSteamCoil(CoilNum)
! SUBROUTINE INFORMATION:
! AUTHOR Rahul Chillar
! DATE WRITTEN Jan 2005
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! This subroutine updates the coil outlet nodes.
! METHODOLOGY EMPLOYED:
! Data is moved from the coil data structure to the coil outlet nodes.
! REFERENCES:
! na
! USE STATEMENTS:
USE DataContaminantBalance, ONLY: Contaminant
USE PlantUtilities, ONLY: SafeCopyPlantNode
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
Integer, Intent(In) :: CoilNum
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
Integer :: AirInletNode
Integer :: SteamInletNode
Integer :: AirOutletNode
Integer :: SteamOutletNode
AirInletNode = SteamCoil(CoilNum)%AirInletNodeNum
SteamInletNode = SteamCoil(CoilNum)%SteamInletNodeNum
AirOutletNode = SteamCoil(CoilNum)%AirOutletNodeNum
SteamOutletNode = SteamCoil(CoilNum)%SteamOutletNodeNum
! Set the outlet air nodes of the SteamCoil
Node(AirOutletNode)%MassFlowRate = SteamCoil(CoilNum)%OutletAirMassFlowRate
Node(AirOutletNode)%Temp = SteamCoil(CoilNum)%OutletAirTemp
Node(AirOutletNode)%HumRat = SteamCoil(CoilNum)%OutletAirHumRat
Node(AirOutletNode)%Enthalpy = SteamCoil(CoilNum)%OutletAirEnthalpy
CALL SafeCopyPlantNode(SteamInletNode, SteamOutletNode)
! Set the outlet Steam nodes for the Coil
! Node(SteamOutletNode)%MassFlowRate = SteamCoil(CoilNum)%OutletSteamMassFlowRate
Node(SteamOutletNode)%Temp = SteamCoil(CoilNum)%OutletSteamTemp
Node(SteamOutletNode)%Enthalpy = SteamCoil(CoilNum)%OutletWaterEnthalpy
Node(SteamOutletNode)%Quality = SteamCoil(CoilNum)%OutletSteamQuality
!Node(SteamInletNode)%MassFlowRate = SteamCoil(CoilNum)%OutletSteamMassFlowRate
! Set the outlet nodes for properties that just pass through & not used
Node(AirOutletNode)%Quality = Node(AirInletNode)%Quality
Node(AirOutletNode)%Press = Node(AirInletNode)%Press
Node(AirOutletNode)%MassFlowRateMin = Node(AirInletNode)%MassFlowRateMin
Node(AirOutletNode)%MassFlowRateMax = Node(AirInletNode)%MassFlowRateMax
Node(AirOutletNode)%MassFlowRateMinAvail= Node(AirInletNode)%MassFlowRateMinAvail
Node(AirOutletNode)%MassFlowRateMaxAvail= Node(AirInletNode)%MassFlowRateMaxAvail
! Set the outlet nodes for properties that just pass through & not used
!Node(SteamOutletNode)%Press = Node(SteamInletNode)%Press
! Node(SteamOutletNode)%Press = StdBaroPress ! Water out at atm pressure
! Node(SteamOutletNode)%HumRat = Node(SteamInletNode)%HumRat
! Node(SteamOutletNode)%MassFlowRateMin = Node(SteamInletNode)%MassFlowRateMin
! Node(SteamOutletNode)%MassFlowRateMax = Node(SteamInletNode)%MassFlowRateMax
! Node(SteamOutletNode)%MassFlowRateMinAvail= Node(SteamInletNode)%MassFlowRateMinAvail
! Node(SteamOutletNode)%MassFlowRateMaxAvail= Node(SteamInletNode)%MassFlowRateMaxAvail
! IF (SteamCoil(CoilNum)%InletSteamMassFlowRate.EQ.0.0) THEN
! Node(SteamInletNode)%MassFlowRate = 0.0
! Node(SteamInletNode)%MassFlowRateMinAvail = 0.0
! Node(SteamOutletNode)%MassFlowRateMinAvail= 0.0
! END IF
IF (Contaminant%CO2Simulation) Then
Node(AirOutletNode)%CO2 = Node(AirInletNode)%CO2
End If
IF (Contaminant%GenericContamSimulation) Then
Node(AirOutletNode)%GenContam = Node(AirInletNode)%GenContam
End If
RETURN