Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
| Type | Intent | Optional | Attributes | Name | ||
|---|---|---|---|---|---|---|
| character(len=*), | intent(in) | :: | ZoneEquipName | |||
| integer, | intent(inout) | :: | ATMixerOutNode | 
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE GetATMixerOutNode(ZoneEquipName,ATMixerOutNode)
          ! SUBROUTINE INFORMATION:
          !       AUTHOR
          !       DATE WRITTEN   April 2012
          !       MODIFIED       na
          !       RE-ENGINEERED  na
          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine gets the mixed air outlet node for a given ATMixer
          ! METHODOLOGY EMPLOYED:
          ! na
          ! REFERENCES:
          ! na
          ! USE STATEMENTS:
  USE InputProcessor, ONLY: FindItemInList
  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine
          ! SUBROUTINE ARGUMENT DEFINITIONS:
  CHARACTER(len=*), INTENT(IN) :: ZoneEquipName
  INTEGER, INTENT(INOUT)       :: ATMixerOutNode
          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na
          ! INTERFACE BLOCK SPECIFICATIONS
          ! na
          ! DERIVED TYPE DEFINITIONS
          ! na
          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
  INTEGER :: ATMixerIndex ! local air terminal mixer index
  LOGICAL ErrorsFound ! for error trapping
  IF (GetATMixerFlag) THEN
    CALL GetATMixers
    GetATMixerFlag = .FALSE.
  END IF
  ATMixerIndex = FindItemInList(ZoneEquipName,SysATMixer%Name,NumATMixers)
  IF (ATMixerIndex > 0) THEN
    ATMixerOutNode = SysATMixer(ATMixerIndex)%MixedAirOutNode
  END IF
  IF (ATMixerIndex == 0) THEN
    CALL ShowSevereError('GetATMixerOutNode: Air Terminal Mixer outlet node not found for zone equipment='//TRIM(ZoneEquipName))
    ErrorsFound=.TRUE.
  ENDIF
  RETURN