Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
character(len=*), | intent(in) | :: | ZoneEquipName | |||
integer, | intent(inout) | :: | ATMixerOutNode |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE GetATMixerOutNode(ZoneEquipName,ATMixerOutNode)
! SUBROUTINE INFORMATION:
! AUTHOR
! DATE WRITTEN April 2012
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! This subroutine gets the mixed air outlet node for a given ATMixer
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: FindItemInList
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
CHARACTER(len=*), INTENT(IN) :: ZoneEquipName
INTEGER, INTENT(INOUT) :: ATMixerOutNode
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: ATMixerIndex ! local air terminal mixer index
LOGICAL ErrorsFound ! for error trapping
IF (GetATMixerFlag) THEN
CALL GetATMixers
GetATMixerFlag = .FALSE.
END IF
ATMixerIndex = FindItemInList(ZoneEquipName,SysATMixer%Name,NumATMixers)
IF (ATMixerIndex > 0) THEN
ATMixerOutNode = SysATMixer(ATMixerIndex)%MixedAirOutNode
END IF
IF (ATMixerIndex == 0) THEN
CALL ShowSevereError('GetATMixerOutNode: Air Terminal Mixer outlet node not found for zone equipment='//TRIM(ZoneEquipName))
ErrorsFound=.TRUE.
ENDIF
RETURN
END SUBROUTINE GetATMixerOutNode