Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE UpdateSetPointManagers
! SUBROUTINE INFORMATION:
! AUTHOR Fred Buhl
! DATE WRITTEN July 1998
! MODIFIED Shirey/Raustad (FSEC), Jan 2004
! P. Haves Oct 2004
! Add new setpoint managers:
! SET POINT MANAGER:WARMEST TEMP FLOW and
! SET POINT MANAGER:COLDEST TEMP FLOW
! Nov 2004 M. J. Witte, GARD Analytics, Inc.
! Add new setpoint managers:
! SET POINT MANAGER:SINGLE ZONE HEATING and
! SET POINT MANAGER:SINGLE ZONE COOLING
! Work supported by ASHRAE research project 1254-RP
! B. Griffith Aug. 2006. Allow HUMRAT for scheduled setpoint manager
! P. Haves Aug 2007
! SET POINT MANAGER:WARMEST TEMP FLOW:
! Set AirLoopControlInfo()%LoopFlowRateSet every call not just on
! initialization (flag now reset in SUBROUTINE ResetHVACControl)
! Removed SET POINT MANAGER:COLDEST TEMP FLOW
! July 2010 B.A. Nigusse, FSEC/UCF
! Added new setpoint managers
! SetpointManager:MultiZone:Heating:Average
! SetpointManager:MultiZone:Cooling:Average
! SetpointManager:MultiZone:MinimumHumidity:Average
! SetpointManager:MultiZone:MaximumHumidity:Average
! Aug 2010 B.A. Nigusse, FSEC/UCF
! Added new setpoint managers:
! SetpointManager:MultiZone:Humidity:Minimum
! SetpointManager:MultiZone:Humidity:Maximum
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE
! Loop over all the Setpoint Managers and use their output arrays
! to set the node setpoints.
! METHODOLOGY EMPLOYED:
! REFERENCES:
! na
! USE STATEMENTS:
USE DataGlobals, ONLY: SysSizingCalc, AnyEnergyManagementSystemInModel
USE DataHVACGlobals, ONLY: DoSetPointTest, SetPointErrorFlag
USE EMSManager, ONLY: iTemperatureSetpoint, CheckIfNodeSetpointManagedByEMS
IMPLICIT NONE
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: SetPtMgrNum
INTEGER :: CtrlNodeIndex
INTEGER :: NodeNum
! Loop over all the Scheduled Setpoint Managers
DO SetPtMgrNum=1,NumSchSetPtMgrs
DO CtrlNodeIndex=1,SchSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = SchSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
Select Case (SchSetPtMgr(SetPtMgrNum)%CtrlTypeMode)
! set the setpoint depending on the type of variable being controlled
CASE (iCtrlVarType_Temp)
Node(NodeNum)%TempSetPoint = SchSetPtMgr(SetPtMgrNum)%SetPt
CASE (iCtrlVarType_MaxTemp)
Node(NodeNum)%TempSetPointHi = SchSetPtMgr(SetPtMgrNum)%SetPt
CASE (iCtrlVarType_MinTemp)
Node(NodeNum)%TempSetPointLo = SchSetPtMgr(SetPtMgrNum)%SetPt
CASE (iCtrlVarType_HumRat)
Node(NodeNum)%HumRatSetPoint = SchSetPtMgr(SetPtMgrNum)%SetPt
CASE (iCtrlVarType_MaxHumRat)
Node(NodeNum)%HumRatMax = SchSetPtMgr(SetPtMgrNum)%SetPt
CASE (iCtrlVarType_MinHumRat)
Node(NodeNum)%HumRatMin = SchSetPtMgr(SetPtMgrNum)%SetPt
CASE (iCtrlVarType_MassFlow)
Node(NodeNum)%MassFlowRateSetPoint = SchSetPtMgr(SetPtMgrNum)%SetPt
CASE (iCtrlVarType_MaxMassFlow)
Node(NodeNum)%MassFlowRateMax = SchSetPtMgr(SetPtMgrNum)%SetPt
CASE (iCtrlVarType_MinMassFlow)
Node(NodeNum)%MassFlowRateMin = SchSetPtMgr(SetPtMgrNum)%SetPt
END SELECT
END DO !nodes in list
END DO ! setpoint manger:scheduled
! Loop over all the Scheduled Dual Setpoint Managers
DO SetPtMgrNum=1,NumDualSchSetPtMgrs
DO CtrlNodeIndex=1,DualSchSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = DualSchSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (DualSchSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPointHi = DualSchSetPtMgr(SetPtMgrNum)%SetPtHi ! Set the setpoint High
Node(NodeNum)%TempSetPointLo = DualSchSetPtMgr(SetPtMgrNum)%SetPtLo ! Set the setpoint Low
Node(NodeNum)%TempSetPoint = (Node(NodeNum)%TempSetPointHi + Node(NodeNum)%TempSetPointLo)/2.0d0 ! average of the high and low
END IF
END DO
END DO
! Loop over all the Outside Air Setpoint Managers
DO SetPtMgrNum=1,NumOutAirSetPtMgrs
DO CtrlNodeIndex=1,OutAirSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = OutAirSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (OutAirSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = OutAirSetPtMgr(SetPtMgrNum)%SetPt ! Set the setpoint
END IF
END DO
END DO
! Loop over all the Single Zone Reheat Setpoint Managers
DO SetPtMgrNum=1,NumSZRhSetPtMgrs
DO CtrlNodeIndex=1,SingZoneRhSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = SingZoneRhSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (SingZoneRhSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = SingZoneRhSetPtMgr(SetPtMgrNum)%SetPt ! Set the setpoint
END IF
END DO
END DO
! Loop over all the Single Zone Heating Setpoint Managers
DO SetPtMgrNum=1,NumSZHtSetPtMgrs
DO CtrlNodeIndex=1,SingZoneHtSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = SingZoneHtSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (SingZoneHtSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = SingZoneHtSetPtMgr(SetPtMgrNum)%SetPt ! Set the setpoint
END IF
END DO
END DO
! Loop over all the Single Zone Cooling Setpoint Managers
DO SetPtMgrNum=1,NumSZClSetPtMgrs
DO CtrlNodeIndex=1,SingZoneClSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = SingZoneClSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (SingZoneClSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = SingZoneClSetPtMgr(SetPtMgrNum)%SetPt ! Set the setpoint
END IF
END DO
END DO
! Loop over all the Single Zone Minimum Humidity Setpoint Managers
DO SetPtMgrNum=1,NumSZMinHumSetPtMgrs
DO CtrlNodeIndex=1,SZMinHumSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = SZMinHumSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
Node(NodeNum)%HumRatMin = SZMinHumSetPtMgr(SetPtMgrNum)%SetPt ! Set the setpoint
END DO
END DO
! Loop over all the Single Zone Maximum Humidity Setpoint Managers
DO SetPtMgrNum=1,NumSZMaxHumSetPtMgrs
DO CtrlNodeIndex=1,SZMaxHumSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = SZMaxHumSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
Node(NodeNum)%HumRatMax = SZMaxHumSetPtMgr(SetPtMgrNum)%SetPt ! Set the setpoint
END DO
END DO
! Loop over all the Warmest Setpoint Managers
DO SetPtMgrNum=1,NumWarmestSetPtMgrs
DO CtrlNodeIndex=1,WarmestSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = WarmestSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (WarmestSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = WarmestSetPtMgr(SetPtMgrNum)%SetPt ! Set the setpoint
END IF
END DO
END DO
! Loop over all the Coldest Setpoint Managers
DO SetPtMgrNum=1,NumColdestSetPtMgrs
DO CtrlNodeIndex=1,ColdestSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = ColdestSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (ColdestSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = ColdestSetPtMgr(SetPtMgrNum)%SetPt ! Set the setpoint
END IF
END DO
END DO
! Loop over all the Warmest Temp Flow Setpoint Managers
DO SetPtMgrNum=1,NumWarmestSetPtMgrsTempFlow
DO CtrlNodeIndex=1,WarmestSetPtMgrTempFlow(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = WarmestSetPtMgrTempFlow(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (WarmestSetPtMgrTempFlow(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = WarmestSetPtMgrTempFlow(SetPtMgrNum)%SetPt ! Set the supply air temperature setpoint
AirLoopFlow(WarmestSetPtMgrTempFlow(SetPtMgrNum)%AirLoopNum)%ReqSupplyFrac &
= WarmestSetPtMgrTempFlow(SetPtMgrNum)%Turndown ! Set the supply air flow rate
AirLoopControlInfo(WarmestSetPtMgrTempFlow(SetPtMgrNum)%AirLoopNum)%LoopFlowRateSet = .TRUE. ! PH 8/17/07
END IF
END DO
END DO
DO SetPtMgrNum=1,NumRABFlowSetPtMgrs
NodeNum = RABFlowSetPtMgr(SetPtMgrNum)%RABSplitOutNode ! Get the node number
IF (RABFlowSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MassFlow) THEN
Node(NodeNum)%MassFlowRateSetPoint = RABFlowSetPtMgr(SetPtMgrNum)%FlowSetPt ! Set the flow setpoint
END IF
END DO
! Loop over all the MultiZone Average Cooling Setpoint Managers
DO SetPtMgrNum=1,NumMZClgAverageSetPtMGrs
DO CtrlNodeIndex=1,MZAverageCoolingSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = MZAverageCoolingSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (MZAverageCoolingSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = MZAverageCoolingSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
END IF
END DO
END DO
! Loop over all the MultiZone Average Heating Setpoint Managers
DO SetPtMgrNum=1,NumMZHtgAverageSetPtMGrs
DO CtrlNodeIndex=1,MZAverageHeatingSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = MZAverageHeatingSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (MZAverageHeatingSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = MZAverageHeatingSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
END IF
END DO
END DO
! Loop over all the MultiZone Average Minimum Humidity Setpoint Managers
DO SetPtMgrNum=1, NumMZAverageMinHumSetPtMgrs
DO CtrlNodeIndex=1,MZAverageMinHumSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = MZAverageMinHumSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (MZAverageMinHumSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MinHumRat) THEN
Node(NodeNum)%HumRatMin = MZAverageMinHumSetPtMgr(SetPtMgrNum)%SetPt ! Set the humidity ratio setpoint
END IF
END DO
END DO
! Loop over all the MultiZone Average Maxiumum Humidity Setpoint Managers
DO SetPtMgrNum=1, NumMZAverageMaxHumSetPtMgrs
DO CtrlNodeIndex=1,MZAverageMaxHumSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = MZAverageMaxHumSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (MZAverageMaxHumSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MaxHumRat) THEN
Node(NodeNum)%HumRatMax = MZAverageMaxHumSetPtMgr(SetPtMgrNum)%SetPt ! Set the humidity ratio setpoint
END IF
END DO
END DO
! Loop over all the Multizone Minimum Humidity Ratio Setpoint Managers
DO SetPtMgrNum=1, NumMZMinHumSetPtMgrs
DO CtrlNodeIndex=1,MZMinHumSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = MZMinHumSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (MZMinHumSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MinHumRat) THEN
Node(NodeNum)%HumRatMin = MZMinHumSetPtMgr(SetPtMgrNum)%SetPt ! Set the humidity ratio setpoint
END IF
END DO
END DO
! Loop over all the Multizone Maximum Humidity Ratio Setpoint Managers
DO SetPtMgrNum=1, NumMZMaxHumSetPtMgrs
DO CtrlNodeIndex=1,MZMaxHumSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = MZMaxHumSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (MZMaxHumSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MaxHumRat) THEN
Node(NodeNum)%HumRatMax = MZMaxHumSetPtMgr(SetPtMgrNum)%SetPt ! Set the humidity ratio setpoint
END IF
END DO
END DO
! Loop over all the Follow Outdoor Air Setpoint Managers
DO SetPtMgrNum=1,NumFollowOATempSetPtMgrs
DO CtrlNodeIndex=1,FollowOATempSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = FollowOATempSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (FollowOATempSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = FollowOATempSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
ELSEIF (FollowOATempSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MaxTemp) THEN
Node(NodeNum)%TempSetPointHi = FollowOATempSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
ELSEIF (FollowOATempSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MinTemp) THEN
Node(NodeNum)%TempSetPointLo = FollowOATempSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
END IF
END DO
END DO
! Loop over all the Follow System Node Temperature Setpoint Managers
DO SetPtMgrNum=1,NumFollowSysNodeTempSetPtMgrs
DO CtrlNodeIndex=1,FollowSysNodeTempSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = FollowSysNodeTempSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (FollowSysNodeTempSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = FollowSysNodeTempSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
ELSEIF (FollowSysNodeTempSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MaxTemp) THEN
Node(NodeNum)%TempSetPointHi = FollowSysNodeTempSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
ELSEIF (FollowSysNodeTempSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MinTemp) THEN
Node(NodeNum)%TempSetPointLo = FollowSysNodeTempSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
END IF
END DO
END DO
! Loop over all the Ground Tempearture Setpoint Managers
DO SetPtMgrNum=1,NumGroundTempSetPtMgrs
DO CtrlNodeIndex=1,GroundTempSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! setpoints from this setpoint manager
NodeNum = GroundTempSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (GroundTempSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = GroundTempSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
ELSEIF (GroundTempSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MaxTemp) THEN
Node(NodeNum)%TempSetPointHi = GroundTempSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
ELSEIF (GroundTempSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_MinTemp) THEN
Node(NodeNum)%TempSetPointLo = GroundTempSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
END IF
END DO
END DO
! Loop over all Condenser Entering Set Point Managers
DO SetPtMgrNum=1,NumCondEntSetPtMgrs
DO CtrlNodeIndex=1,CondEntSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! set points from this set point manager
NodeNum = CondEntSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (CondEntSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = CondEntSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
END IF
END DO
END DO
! Loop over all Ideal Condenser Entering Set Point Managers
DO SetPtMgrNum=1,NumIdealCondEntSetPtMgrs
DO CtrlNodeIndex=1,IdealCondEntSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! set points from this set point manager
NodeNum = IdealCondEntSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (IdealCondEntSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = IdealCondEntSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
END IF
END DO
END DO
!loop over all single zone on/off cooling setpoint managers
DO SetPtMgrNum=1,NumSZOneStageCoolingSetPtMgrs
DO CtrlNodeIndex=1,SZOneStageCoolingSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! set points from this set point manager
NodeNum = SZOneStageCoolingSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (SZOneStageCoolingSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = SZOneStageCoolingSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
END IF
END DO
ENDDO
!loop over all single zone on/off heating setpoint managers
DO SetPtMgrNum=1,NumSZOneStageHeatingSetPtMgrs
DO CtrlNodeIndex=1,SZOneStageHeatingSetPtMgr(SetPtMgrNum)%NumCtrlNodes ! Loop over the list of nodes wanting
! set points from this set point manager
NodeNum = SZOneStageHeatingSetPtMgr(SetPtMgrNum)%CtrlNodes(CtrlNodeIndex) ! Get the node number
IF (SZOneStageHeatingSetPtMgr(SetPtMgrNum)%CtrlTypeMode == iCtrlVarType_Temp) THEN
Node(NodeNum)%TempSetPoint = SZOneStageHeatingSetPtMgr(SetPtMgrNum)%SetPt ! Set the temperature setpoint
END IF
END DO
ENDDO
RETURN
END SUBROUTINE UpdateSetPointManagers