Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
integer, | intent(in) | :: | WaterConnNum |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE UpdateWaterConnections(WaterConnNum)
! SUBROUTINE INFORMATION:
! AUTHOR Peter Graham Ellis
! DATE WRITTEN August 2006
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! Updates the node variables with local variables.
! METHODOLOGY EMPLOYED:
! Standard EnergyPlus methodology.
! USE STATEMENTS:
USE DataLoopNode, ONLY: Node
USE PlantUtilities, ONLY: SafeCopyPlantNode
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
INTEGER, INTENT(IN) :: WaterConnNum
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: InletNode
INTEGER :: OutletNode
INTEGER :: LoopNum
! FLOW:
InletNode = WaterConnections(WaterConnNum)%InletNode
OutletNode = WaterConnections(WaterConnNum)%OutletNode
LoopNum = WaterConnections(WaterConnNum)%PlantLoopNum
IF (InletNode > 0 .AND. OutletNode > 0) THEN
! Pass all variables from inlet to outlet node
CALL SafeCopyPlantNode( InletNode, OutletNode, LoopNum )
! DSU3 Node(OutletNode) = Node(InletNode)
! Set outlet node variables that are possibly changed
Node(OutletNode)%Temp = WaterConnections(WaterConnNum)%ReturnTemp
! should add enthalpy update to return?
END IF
RETURN
END SUBROUTINE UpdateWaterConnections