Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
| Type | Intent | Optional | Attributes | Name | ||
|---|---|---|---|---|---|---|
| integer, | intent(in) | :: | ATMixerNum | |||
| logical, | intent(in) | :: | FirstHVACIteration | 
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE InitATMixer(ATMixerNum,FirstHVACIteration)
          ! SUBROUTINE INFORMATION:
          !       AUTHOR
          !       DATE WRITTEN   March 2012
          !       MODIFIED       na
          !       RE-ENGINEERED  na
          ! PURPOSE OF THIS SUBROUTINE
          ! Initialize the AirTerminalMixers data structure with node data
          ! METHODOLOGY EMPLOYED:
          ! REFERENCES:
          ! USE STATEMENTS:
    USE DataLoopNode
    IMPLICIT NONE
          ! SUBROUTINE ARGUMENT DEFINITIONS
    INTEGER, INTENT(IN) :: ATMixerNum
    LOGICAL, INTENT(IN) :: FirstHVACIteration
          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! INTERFACE BLOCK SPECIFICATIONS
          ! na
          ! DERIVED TYPE DEFINITIONS
          ! na
          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: InletNode
INTEGER :: PriInNode
INTEGER :: MixedAirOutNode
InletNode = SysATMixer(ATMixerNum)%SecInNode
PriInNode = SysATMixer(ATMixerNum)%PriInNode
MixedAirOutNode = SysATMixer(ATMixerNum)%MixedAirOutNode
IF (FirstHVACIteration) THEN
!  SysATMixer(ATMixerNum)%ZoneAirMassFlowRate = SysATMixer(ATMixerNum)%MaxAirMassFlowRate
END IF
IF (BeginDayFlag) THEN
END IF
IF (FirstHVACIteration) THEN
END IF
RETURN
END SUBROUTINE InitATMixer