Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE ReportDirectAir(DirectAirNum)
! SUBROUTINE INFORMATION:
! AUTHOR: Russ Taylor
! DATE WRITTEN: Nov 1997
! PURPOSE OF THIS SUBROUTINE: This subroutine
! METHODOLOGY EMPLOYED:
! REFERENCES:
! USE STATEMENTS:
Use DataHVACGlobals, ONLY: TimeStepSys
IMPLICIT NONE
INTEGER :: DirectAirNum
!report the Direct Air Output
DirectAir(DirectAirNum)%HeatRate = MAX(DirectAir(DirectAirNum)%SensOutputProvided,0.0d0)
DirectAir(DirectAirNum)%CoolRate = Abs(MIN(DirectAir(DirectAirNum)%SensOutputProvided,0.0d0))
DirectAir(DirectAirNum)%HeatEnergy = MAX(DirectAir(DirectAirNum)%SensOutputProvided,0.0d0)*TimeStepSys*SecInHour
DirectAir(DirectAirNum)%CoolEnergy = Abs(MIN(DirectAir(DirectAirNum)%SensOutputProvided,0.0d0)*TimeStepSys*SecInHour)
RETURN