Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
| Type | Intent | Optional | Attributes | Name | ||
|---|---|---|---|---|---|---|
| integer, | intent(in) | :: | CoilNum | 
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE ReportHeatingCoil(CoilNum)
          ! SUBROUTINE INFORMATION:
          !       AUTHOR         Richard Liesen
          !       DATE WRITTEN   May 2000
          !       MODIFIED       na
          !       RE-ENGINEERED  na
          ! PURPOSE OF THIS SUBROUTINE:
          ! This subroutine updates the report variable for the coils.
          ! METHODOLOGY EMPLOYED:
          ! NA
          ! REFERENCES:
          ! na
          ! USE STATEMENTS:
  Use DataHVACGlobals, ONLY: TimeStepSys
  IMPLICIT NONE    ! Enforce explicit typing of all variables in this routine
          ! SUBROUTINE ARGUMENT DEFINITIONS:
  Integer, Intent(IN) :: CoilNum
          ! SUBROUTINE PARAMETER DEFINITIONS:
          ! na
          ! INTERFACE BLOCK SPECIFICATIONS
          ! na
          ! DERIVED TYPE DEFINITIONS
          ! na
          ! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
   REAL(r64) :: ReportingConstant
   ReportingConstant = TimeStepSys*SecInHour
 ! report the HeatingCoil energy from this component
   HeatingCoil(CoilNum)%HeatingCoilRate  = HeatingCoil(CoilNum)%HeatingCoilLoad
   HeatingCoil(CoilNum)%HeatingCoilLoad  = HeatingCoil(CoilNum)%HeatingCoilLoad*ReportingConstant
   HeatingCoil(CoilNum)%GasUseRate       = HeatingCoil(CoilNum)%GasUseLoad
   HeatingCoil(CoilNum)%ElecUseRate      = HeatingCoil(CoilNum)%ElecUseLoad
   HeatingCoil(CoilNum)%GasUseLoad       = HeatingCoil(CoilNum)%GasUseLoad*ReportingConstant
   HeatingCoil(CoilNum)%ElecUseLoad      = HeatingCoil(CoilNum)%ElecUseLoad*ReportingConstant
   HeatingCoil(CoilNum)%ParasiticGasLoad = HeatingCoil(CoilNum)%ParasiticGasRate*ReportingConstant
  RETURN