Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
character(len=*), | intent(in) | :: | CoilType | |||
character(len=*), | intent(in) | :: | CoilName | |||
logical, | intent(inout) | :: | ErrorsFound |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
FUNCTION GetCoilCapacity(CoilType,CoilName,ErrorsFound) RESULT(CoilCapacity)
! FUNCTION INFORMATION:
! AUTHOR Linda Lawrie
! DATE WRITTEN February 2006
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS FUNCTION:
! This function looks up the coil capacity for the given coil and returns it. If
! incorrect coil type or name is given, errorsfound is returned as true and capacity is returned
! as negative.
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE FluidProperties, ONLY: FindGlycol
USE InputProcessor, ONLY: FindItemInList, SameString
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! FUNCTION ARGUMENT DEFINITIONS:
CHARACTER(len=*), INTENT(IN) :: CoilType ! must match coil types in this module
CHARACTER(len=*), INTENT(IN) :: CoilName ! must match coil names for the coil type
LOGICAL, INTENT(INOUT) :: ErrorsFound ! set to true if problem
REAL(r64) :: CoilCapacity ! returned capacity of matched coil
! FUNCTION PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! FUNCTION LOCAL VARIABLE DECLARATIONS:
INTEGER :: WhichCoil
! Obtains and Allocates WatertoAirHP related parameters from input file
IF (GetCoilsInputFlag) THEN !First time subroutine has been entered
WaterIndex=FindGlycol('WATER') !Initialize the WaterIndex once
CALL GetWatertoAirHPInput
GetCoilsInputFlag=.false.
End If
IF (SameString(CoilType,'COIL:HEATING:WATERTOAIRHEATPUMP:PARAMETERESTIMATION') .or. &
SameString(CoilType,'COIL:COOLING:WATERTOAIRHEATPUMP:PARAMETERESTIMATION')) THEN
WhichCoil=FindItemInList(CoilName,WaterToAirHP%Name,NumWaterToAirHPs)
IF (WhichCoil /= 0) THEN
IF (SameString(CoilType,'COIL:HEATING:WATERTOAIRHEATPUMP:PARAMETERESTIMATION')) THEN
CoilCapacity=WaterToAirHP(WhichCoil)%HeatingCapacity
ELSE
CoilCapacity=WaterToAirHP(WhichCoil)%CoolingCapacity
ENDIF
ENDIF
ELSE
WhichCoil=0
ENDIF
IF (WhichCoil == 0) THEN
CALL ShowSevereError('Could not find CoilType="'//TRIM(CoilType)//'" with Name="'//TRIM(CoilName)//'"')
ErrorsFound=.true.
CoilCapacity=-1000.0d0
ENDIF
RETURN
END FUNCTION GetCoilCapacity