Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
integer, | intent(in) | :: | MeterNumber |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
FUNCTION GetCurrentMeterValue(MeterNumber) RESULT(CurrentMeterValue)
! FUNCTION INFORMATION:
! AUTHOR Linda K. Lawrie
! DATE WRITTEN August 2002
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS FUNCTION:
! This function returns the current meter value (timestep) for the meter number indicated.
! METHODOLOGY EMPLOYED:
! Uses internal EnergyMeters structure to get value.
! REFERENCES:
! na
! USE STATEMENTS:
USE DataPrecisionGlobals
USE OutputProcessor
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! FUNCTION ARGUMENT DEFINITIONS:
INTEGER, INTENT(IN) :: MeterNumber ! Which Meter Number (from GetMeterIndex)
REAL(r64) :: CurrentMeterValue
! FUNCTION PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! FUNCTION LOCAL VARIABLE DECLARATIONS:
! na
IF (MeterNumber > 0) THEN
CurrentMeterValue=EnergyMeters(MeterNumber)%CurTSValue
ELSE
CurrentMeterValue=0.0d0
ENDIF
RETURN
END FUNCTION GetCurrentMeterValue