Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
character(len=*), | intent(in) | :: | CoilType | |||
character(len=*), | intent(in) | :: | CoilName | |||
logical, | intent(inout) | :: | ErrorsFound |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
FUNCTION GetHeatReclaimSourceIndex(CoilType,CoilName,ErrorsFound) RESULT(CoilFound)
! FUNCTION INFORMATION:
! AUTHOR Richard Raustad
! DATE WRITTEN June 2007
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS FUNCTION:
! This function looks up the given coil and returns the heating coil index number if it is a desuperheating coil.
! If incorrect coil type or name is given, errorsfound is returned as true and index number is returned
! as zero.
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: FindItemInList, SameString
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! FUNCTION ARGUMENT DEFINITIONS:
CHARACTER(len=*), INTENT(IN) :: CoilType ! must match coil types in this module
CHARACTER(len=*), INTENT(IN) :: CoilName ! must match coil names for the coil type
LOGICAL, INTENT(INOUT) :: ErrorsFound ! set to true if problem
INTEGER :: CoilFound ! returned index number of matched coil
! FUNCTION PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! FUNCTION LOCAL VARIABLE DECLARATIONS:
LOGICAL :: GetCoilErrFlag
LOGICAL :: SuppressWarning
INTEGER :: NumCoil
INTEGER :: CoilNum
! Obtains and Allocates HeatingCoil related parameters from input file
IF (GetCoilsInputFlag) THEN !First time subroutine has been entered
CALL GetHeatingCoilInput
GetCoilsInputFlag=.false.
End If
SuppressWarning = .TRUE.
CoilFound = 0
!This function only used for dessicant regeneration and refrigeration desuperheat not a valid source
!IF (SameString(CoilType,'REFRIGERATION:COMPRESSORRACK')) THEN
! CALL GetRefrigeratedRackIndex(CoilName, CoilNum,RefrigSystemTypeRack, GetCoilErrFlag, CoilType, SuppressWarning)
! DO NumCoil = 1, NumHeatingCoils
! IF(HeatingCoil(NumCoil)%ReclaimHeatingSource .NE. COMPRESSORRACK_REFRIGERATEDCASE .AND. &
! HeatingCoil(NumCoil)%ReclaimHeatingCoilName .NE. CoilName)CYCLE
! CoilFound = CoilNum
! EXIT
! END DO
! ELSEIF (SameString(CoilType,'REFRIGERATION:CONDENSER')) THEN bbb
! CALL GetRefrigeratedRackIndex(CoilName, CoilNum,RefrigSystemTypeDetailed, GetCoilErrFlag, CoilType, SuppressWarning)
! DO NumCoil = 1, NumHeatingCoils
! IF(HeatingCoil(NumCoil)%ReclaimHeatingSource .NE. CONDENSER_REFRIGERATION .AND. &
! HeatingCoil(NumCoil)%ReclaimHeatingCoilName .NE. CoilName)CYCLE
! CoilFound = CoilNum
! EXIT
! END DO
! ELSEIF
!note should eventually get rid of this string comparison
IF(SameString(CoilType,'COIL:COOLING:DX:SINGLESPEED') .or. &
SameString(CoilType,'COIL:COOLING:DX:TWOSPEED') .or. &
SameString(CoilType,'COIL:COOLING:DX:TWOSTAGEWITHHUMIDITYCONTROLMODE')) THEN
CALL GetDXCoilIndex(CoilName,CoilNum, GetCoilErrFlag, CoilType, SuppressWarning)
DO NumCoil = 1, NumHeatingCoils
IF(HeatingCoil(NumCoil)%ReclaimHeatingSource .NE. COIL_DX_COOLING .AND. &
HeatingCoil(NumCoil)%ReclaimHeatingSource .NE. COIL_DX_MULTISPEED .AND. &
HeatingCoil(NumCoil)%ReclaimHeatingSource .NE. COIL_DX_MULTIMODE .AND. &
HeatingCoil(NumCoil)%ReclaimHeatingCoilName .NE. CoilName)CYCLE
CoilFound = CoilNum
EXIT
END DO
ENDIF
IF (CoilNum == 0) THEN
ErrorsFound=.true.
ENDIF
RETURN
END FUNCTION GetHeatReclaimSourceIndex