Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
integer, | intent(in) | :: | UnitNum |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE SizeZoneEvaporativeCoolerUnit(UnitNum)
! SUBROUTINE INFORMATION:
! AUTHOR B. Griffith
! DATE WRITTEN July 2013
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
USE ReportSizingManager, ONLY: ReportSizingOutput
USE DataSizing, ONLY: Autosize, CurZoneEqNum, FinalZoneSizing
USE DataHVACGlobals, ONLY: SmallAirVolFlow
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
INTEGER, INTENT (IN) :: UnitNum ! unit number
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
IF (ZoneEvapUnit(UnitNum)%DesignAirVolumeFlowRate == AutoSize) THEN
IF (CurZoneEqNum > 0) THEN
CALL CheckZoneSizing('ZoneHVAC:EvaporativeCoolerUnit',ZoneEvapUnit(UnitNum)%Name)
ZoneEvapUnit(UnitNum)%DesignAirVolumeFlowRate = FinalZoneSizing(CurZoneEqNum)%DesCoolVolFlow
IF (ZoneEvapUnit(UnitNum)%DesignAirVolumeFlowRate < SmallAirVolFlow) THEN
ZoneEvapUnit(UnitNum)%DesignAirVolumeFlowRate = 0.d0
ENDIF
CALL ReportSizingOutput('ZoneHVAC:EvaporativeCoolerUnit', ZoneEvapUnit(UnitNum)%Name, &
'Design Supply Air Flow Rate [m3/s]', ZoneEvapUnit(UnitNum)%DesignAirVolumeFlowRate)
ENDIF
ENDIF
RETURN
END SUBROUTINE SizeZoneEvaporativeCoolerUnit