Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
character(len=*), | intent(in) | :: | CoilType | |||
character(len=*), | intent(in) | :: | CoilName | |||
logical, | intent(inout) | :: | ErrorsFound |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
FUNCTION GetHXCoilAirFlowRate(CoilType,CoilName,ErrorsFound) RESULT(MaxAirFlowRate)
! FUNCTION INFORMATION:
! AUTHOR Richard Raustad
! DATE WRITTEN September 2013
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS FUNCTION:
! This function looks up the max air flow rate for the given HX and returns it. If
! incorrect coil type or name is given, errorsfound is returned as true and capacity is returned
! as negative.
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: FindItem,SameString
USE HeatRecovery, ONLY: GetSupplyAirFlowRate
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! FUNCTION ARGUMENT DEFINITIONS:
CHARACTER(len=*), INTENT(IN) :: CoilType ! must match coil types in this module
CHARACTER(len=*), INTENT(IN) :: CoilName ! must match coil names for the coil type
LOGICAL, INTENT(INOUT) :: ErrorsFound ! set to true if problem
REAL(r64) :: MaxAirFlowRate ! returned max air flow rate of matched HX
! FUNCTION PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! FUNCTION LOCAL VARIABLE DECLARATIONS:
INTEGER :: WhichCoil
INTEGER, SAVE :: ErrCount=0
! Obtains and allocates HXAssistedCoolingCoil related parameters from input file
IF (GetCoilsInputFlag) THEN ! First time subroutine has been called, get input data
! Get the HXAssistedCoolingCoil input
CALL GetHXAssistedCoolingCoilInput
GetCoilsInputFlag=.false. ! Set logic flag to disallow getting the input data on future calls to this subroutine
End If
IF(TotalNumHXAssistedCoils .GT. 0)THEN
WhichCoil=FindItem(CoilName,HXAssistedCoil%Name,TotalNumHXAssistedCoils)
IF (SameString(CoilType,'CoilSystem:Cooling:DX:HeatExchangerAssisted') .OR. &
SameString(CoilType,'CoilSystem:Cooling:Water:HeatExchangerAssisted')) THEN
IF (WhichCoil /= 0) THEN
MaxAirFlowRate=GetSupplyAirFlowRate(HXAssistedCoil(WhichCoil)%HeatExchangerName,ErrorsFound)
ENDIF
ELSE
WhichCoil=0
ENDIF
IF (WhichCoil == 0) THEN
CALL ShowSevereError('GetHXCoilAirFlowRate: Could not find HX, Type="'//TRIM(CoilType)// &
'" Name="'//TRIM(CoilName)//'"')
ErrorsFound=.true.
MaxAirFlowRate=-1000.d0
ENDIF
ELSE
CALL ShowSevereError('GetHXCoilAirFlowRate: Could not find HX, Type="'//TRIM(CoilType)// &
'" Name="'//TRIM(CoilName)//'"')
ErrorsFound=.true.
MaxAirFlowRate=-1000.d0
END IF
RETURN
END FUNCTION GetHXCoilAirFlowRate