Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
logical, | intent(inout) | :: | SimAir |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE UpdateZoneEquipment(SimAir)
! SUBROUTINE INFORMATION:
! AUTHOR Russ Taylor
! DATE WRITTEN Nov 1997
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! This subroutine performs the update for Zone Equipment Management.
! Specifically, it transfers the conditions from the zone equipment return air nodes across
! to the air loop side, allowing for multiple return air nodes
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE HVACInterfaceManager, ONLY : UpdateHVACInterface
USE DataAirLoop, ONLY : AirToZoneNodeInfo
USE DataHVACGlobals, ONLY : NumPrimaryAirSys
USE DataConvergParams, ONLY : CalledFromAirSystemDemandSide
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
LOGICAL, INTENT(INOUT) :: SimAir
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: ZoneGroupNum
INTEGER :: RetAirPathNum
! Transfer the conditions from the zone equipment return air nodes across
! to the air loop side, allowing for multiple return air nodes
DO ZoneGroupNum = 1, NumPrimaryAirSys
DO RetAirPathNum = 1, AirToZoneNodeInfo(ZoneGroupNum)%NumReturnNodes
CALL UpdateHVACInterface(ZoneGroupNum, CalledFromAirSystemDemandSide, &
AirToZoneNodeInfo(ZoneGroupNum)%ZoneEquipReturnNodeNum(RetAirPathNum), &
AirToZoneNodeInfo(ZoneGroupNum)%AirLoopReturnNodeNum(RetAirPathNum), &
SimAir)
END DO
END DO
RETURN
END SUBROUTINE UpdateZoneEquipment