Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE SimDuct(CompName,FirstHVACIteration,CompIndex)
! SUBROUTINE INFORMATION:
! AUTHOR Fred Buhl
! DATE WRITTEN 17May2005
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! Manage the simulation of a duct component
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: FindItemInList
USE General, ONLY: TrimSigDigits
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
CHARACTER(len=*), INTENT (IN) :: CompName ! name of the duct component
LOGICAL, INTENT (IN) :: FirstHVACIteration ! TRUE if 1st HVAC simulation of system timestep !unused1208
INTEGER, INTENT (INOUT) :: CompIndex ! index of duct component
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
LOGICAL,SAVE :: GetInputFlag = .true. ! First time, input is "gotten"
INTEGER :: DuctNum ! index of duct being simulated
IF (GetInputFlag) THEN
CALL GetDuctInput
GetInputFlag=.false.
ENDIF
! Get the duct component index
IF (CompIndex == 0) THEN
DuctNum = FindItemInList(CompName,Duct%Name,NumDucts)
IF (DuctNum == 0) THEN
CALL ShowFatalError('SimDuct: Component not found='//TRIM(CompName))
ENDIF
CompIndex=DuctNum
ELSE
DuctNum=CompIndex
IF (DuctNum > NumDucts .or. DuctNum < 1) THEN
CALL ShowFatalError('SimDuct: Invalid CompIndex passed='// &
TRIM(TrimSigDigits(DuctNum))// &
', Number of Components='//TRIM(TrimSigDigits(NumDucts))// &
', Entered Component name='//TRIM(CompName))
ENDIF
IF (CheckEquipName(DuctNum)) THEN
IF (CompName /= Duct(DuctNum)%Name) THEN
CALL ShowFatalError('SimDuct: Invalid CompIndex passed='// &
TRIM(TrimSigDigits(DuctNum))// &
', Component name='//TRIM(CompName)//', stored Component Name for that index='// &
TRIM(Duct(DuctNum)%Name))
ENDIF
CheckEquipName(DuctNum)=.false.
ENDIF
ENDIF
CALL InitDuct(DuctNum)
CALL CalcDuct(DuctNum)
CALL UpdateDuct(DuctNum)
CALL ReportDuct(DuctNum)
RETURN