Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
character(len=*), | intent(in) | :: | CoilType | |||
character(len=*), | intent(in) | :: | CoilName | |||
real(kind=r64), | intent(in) | :: | CoilDesFlow | |||
logical, | intent(inout) | :: | ErrorsFound |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE SetCoilDesFlow(CoilType,CoilName,CoilDesFlow, ErrorsFound)
! SUBROUTINE INFORMATION:
! AUTHOR Fred Buhl
! DATE WRITTEN May 2009
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! This routine is designed to set the design air volume flow rate in the
! water coil data structure. Some of the coil types do not have this datum as
! an input parameter and it is needed for calculating capacity for output reporting.
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: FindItem,SameString
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! FUNCTION ARGUMENT DEFINITIONS:
CHARACTER(len=*), INTENT(IN) :: CoilType ! must match coil types in this module
CHARACTER(len=*), INTENT(IN) :: CoilName ! must match coil names for the coil type
LOGICAL, INTENT(INOUT) :: ErrorsFound ! set to true if problem
REAL(r64), INTENT(IN) :: CoilDesFlow ! coil volumetric air flow rate [m3/s]
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: WhichCoil ! index to coil
IF (GetWaterCoilsInputFlag) THEN !First time subroutine has been entered
CALL GetWaterCoilInput
GetWaterCoilsInputFlag=.false.
End If
IF (SameString(CoilType,'Coil:Heating:Water') .or. SameString(CoilType,'Coil:Cooling:Water:DetailedGeometry') .or. &
SameString(CoilType,'Coil:Cooling:Water')) THEN
WhichCoil=FindItem(CoilName,WaterCoil%Name,NumWaterCoils)
IF (WhichCoil /= 0) THEN
IF (SameString(CoilType,'Coil:Cooling:Water') .and. WaterCoil(WhichCoil)%DesAirVolFlowRate < 0.0d0) THEN
WaterCoil(WhichCoil)%DesAirVolFlowRate = CoilDesFlow
ELSE
WaterCoil(WhichCoil)%DesAirVolFlowRate = CoilDesFlow
END IF
ELSE
CALL ShowSevereError('GetCoilMaxWaterFlowRate: Could not find Coil, Type="'//TRIM(CoilType)// &
'" Name="'//TRIM(CoilName)//'"')
ErrorsFound=.true.
ENDIF
ENDIF