Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
integer, | intent(in) | :: | CompTypeNum | |||
integer, | intent(in) | :: | CompNum |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE UpdatePlantValves(CompTypeNum,CompNum)
! SUBROUTINE INFORMATION:
! AUTHOR B. Griffith, NREL
! DATE WRITTEN Jan. 2006
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! Propagate calculations to rest of program
! METHODOLOGY EMPLOYED:
! set values at nodes
! REFERENCES:
! na
! USE STATEMENTS:
USE PlantUtilities, ONLY: SetComponentFlowRate, SafeCopyPlantNode
USE DataPlant, ONLY: TypeOf_ValveTempering
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
INTEGER , INTENT(IN) :: CompTypeNum
INTEGER , INTENT(IN) :: CompNum
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
REAL(r64) :: mdot !local fluid mass flow rate
SELECT CASE (CompTypeNum)
CASE (TypeOf_ValveTempering)
CALL SafeCopyPlantNode(TemperValve(CompNum)%PltInletNodeNum, TemperValve(CompNum)%PltOutletNodeNum)
! set mass flows in diverter path
mdot = TemperValve(CompNum)%MixedMassFlowRate &
* TemperValve(CompNum)%FlowDivFract
IF (TemperValve(CompNum)%LoopNum > 0) THEN
CALL SetComponentFlowRate( mdot, &
TemperValve(CompNum)%PltInletNodeNum, &
TemperValve(CompNum)%PltOutletNodeNum, &
TemperValve(CompNum)%LoopNum, &
TemperValve(CompNum)%LoopSideNum, &
TemperValve(CompNum)%BranchNum, &
TemperValve(CompNum)%CompNum )
TemperValve(CompNum)%DivertedFlowRate = mdot
ELSE
TemperValve(CompNum)%DivertedFlowRate = 0.d0
ENDIF
CASE DEFAULT
! should not come here
END SELECT
RETURN
END SUBROUTINE UpdatePlantValves