Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE ReportThermalChimney
! SUBROUTINE INFORMATION:
! AUTHOR Kwang Ho Lee
! DATE WRITTEN April 2008
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! This subroutine fills remaining report variables.
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE DataHVACGlobals, ONLY: TimeStepSys
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: ZoneLoop ! Counter for the # of zones (nz)
REAL(r64) :: AirDensity
REAL(r64) :: CpAir
REAL(r64) :: TSMult
TSMult=TimeStepSys*SecInHour
DO ZoneLoop = 1, NumOfZones ! Start of zone loads report variable update loop ...
! Break the infiltration load into heat gain and loss components.
AirDensity = PsyRhoAirFnPbTdbW(OutBaroPress,MAT(ZoneLoop),ZoneAirHumRat(ZoneLoop))
CpAir = PsyCpAirFnWTdb(ZoneAirHumRat(ZoneLoop),MAT(ZoneLoop))
ZnRptThermChim(ZoneLoop)%ThermalChimneyVolume = (MCPThermChim(ZoneLoop)/CpAir/AirDensity)*TSMult
ZnRptThermChim(ZoneLoop)%ThermalChimneyMass = (MCPThermChim(ZoneLoop)/CpAir)*TSMult
ZnRptThermChim(ZoneLoop)%ThermalChimneyHeatLoss = 0.0d0
ZnRptThermChim(ZoneLoop)%ThermalChimneyHeatGain = 0.0d0
IF (ZT(ZoneLoop) > Zone(ZoneLoop)%OutDryBulbTemp) THEN
ZnRptThermChim(ZoneLoop)%ThermalChimneyHeatLoss = MCPThermChim(ZoneLoop)*(ZT(ZoneLoop)-Zone(ZoneLoop)%OutDryBulbTemp)* &
TSMult
ZnRptThermChim(ZoneLoop)%ThermalChimneyHeatGain=0.0d0
ELSE IF (ZT(ZoneLoop) <= Zone(ZoneLoop)%OutDryBulbTemp) THEN
ZnRptThermChim(ZoneLoop)%ThermalChimneyHeatGain = MCPThermChim(ZoneLoop)*(Zone(ZoneLoop)%OutDryBulbTemp-ZT(ZoneLoop))* &
TSMult
ZnRptThermChim(ZoneLoop)%ThermalChimneyHeatLoss =0.0d0
END IF
END DO ! ... end of zone loads report variable update loop.
RETURN
END SUBROUTINE ReportThermalChimney