TCMF(ZoneNum) = (ZTFloor(ZoneNum) * (HeightOccupiedSubzoneAve - HeightComfort) & + ZTMX(ZoneNum) * (HeightComfort - HeightFloorSubzoneAve)) & / (HeightOccupiedSubzoneAve - HeightFloorSubzoneAve) TempTstatAir(ZoneNum) = (ZTFloor(ZoneNum) * (HeightOccupiedSubzoneAve - HeightThermostat) & + ZTMX(ZoneNum) * (HeightThermostat - HeightFloorSubzoneAve)) & / (HeightOccupiedSubzoneAve - HeightFloorSubzoneAve)
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
integer, | intent(in) | :: | ZoneNum |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE CalcUCSDDV(ZoneNum)
! SUBROUTINE INFORMATION:
! AUTHOR G. Carrilho da Graca
! DATE WRITTEN February 2004
! MODIFIED Brent Griffith June 2008 for new interpolation and time history
! RE-ENGINEERED -
! PURPOSE OF THIS SUBROUTINE:
! Subroutine for displacement ventilation modelling.
! This subroutine calculates the mixed subzone height, surface heat transfer coefficients and
! room air equivalent temperatures and three space temperatures (floor subzone, occupied zone and upper,
! mixed subzone temperature)
! METHODOLOGY EMPLOYED:
! -
! -
! -
! -
! REFERENCES:
! Model developed by Paul Linden (UCSD), G. Carrilho da Graca (UCSD) and P. Haves (LBL).
! Work funded by the California Energy Comission. More information on the model can found in:
! "Simplified Models for Heat Transfer in Rooms" G. Carrilho da Graça, Ph.D. thesis UCSD. December 2003.
! USE STATEMENTS:
USE DataHeatBalFanSys
USE DataEnvironment
USE DataHeatBalance
USE InputProcessor
USE ScheduleManager, ONLY: GetScheduleIndex, GetCurrentScheduleValue
USE DataZoneEquipment, ONLY: ZoneEquipConfig
USE Psychrometrics, ONLY: PsyRhoAirFnPbTdbW, PsyCpAirFnWTdb
USE DataHVACGlobals, ONLY: TimestepSys, UseZoneTimeStepHistory
USE InternalHeatGains, ONLY: SumInternalConvectionGainsByTypes, SumReturnAirConvectionGainsByTypes
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
INTEGER, INTENT(IN) :: ZoneNum ! Which Zonenum
! SUBROUTINE PARAMETER DEFINITIONS:
REAL(r64), PARAMETER :: OneThird=(1.d0/3.d0)
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
REAL(r64) :: HeightFrac ! Fractional height of transition between occupied and mixed subzones
REAL(r64) :: GainsFrac ! Fraction of lower subzone internal gains that mix as opposed to forming plumes
REAL(r64) :: ConvGains ! Total convective gains in the room
REAL(r64) :: ConvGainsOccupiedSubzone ! Total convective gains released in occupied subzone
REAL(r64) :: ConvGainsMixedSubzone ! Total convective gains released in mixed subzone
REAL(r64) :: MCP_Total ! Total capacity rate into the zone - assumed to enter at low level
REAL(r64) :: ZTAveraged
REAL(r64) :: TempDiffCritRep ! Minimum temperature difference between mixed and occupied subzones for reporting
LOGICAL :: MIXFLAG
INTEGER :: CTD
REAL(r64) :: MinFlow
REAL(r64) :: NumPLPP ! Number of plumes per person
INTEGER :: NumberOfOccupants
REAL(r64) :: MTGAUX
INTEGER :: ZoneEquipConfigNum
INTEGER :: NodeNum
REAL(r64) :: PowerInPlumes
REAL(r64) :: SumSysMCp
REAL(r64) :: SumSysMCpT
REAL(r64) :: NodeTemp
REAL(r64) :: MassFlowRate
REAL(r64) :: CpAir
REAL(r64) :: MCpT_Total
INTEGER :: ZoneNodeNum ! index number of the zone node
REAL(r64) :: NumberOfPlumes
REAL(r64) :: SumMCp
REAL(r64) :: SumMCpT
REAL(r64) :: AirCap
REAL(r64) :: TempHistTerm
REAL(r64) :: PowerPerPlume
REAL(r64) :: HeightMixedSubzoneAve ! Height of center of mixed air subzone
REAL(r64) :: HeightOccupiedSubzoneAve ! Height of center of occupied air subzone
REAL(r64) :: HeightFloorSubzoneAve ! Height of center of floor air subzone
REAL(r64) :: HeightThermostat ! Height of center of thermostat/temperature control sensor
REAL(r64) :: HeightComfort ! Height at which air temperature value is used to calculate comfort
REAL(r64) :: CeilingHeight
REAL(r64) :: ZoneMult ! total zone multiplier
INTEGER :: Loop
INTEGER :: FlagApertures
REAL(r64) :: TempDepCoef=0.0d0 ! Formerly CoefSumha, coef in zone temp equation with dimensions of h*A
REAL(r64) :: TempIndCoef=0.0d0 ! Formerly CoefSumhat, coef in zone temp equation with dimensions of h*A(T1
INTEGER, DIMENSION(28) :: IntGainTypesOccupied = (/IntGainTypeOf_People, &
IntGainTypeOf_WaterHeaterMixed, &
IntGainTypeOf_WaterHeaterStratified, &
IntGainTypeOf_ThermalStorageChilledWaterMixed, &
IntGainTypeOf_ThermalStorageChilledWaterStratified, &
IntGainTypeOf_ElectricEquipment, &
IntGainTypeOf_GasEquipment, &
IntGainTypeOf_HotWaterEquipment, &
IntGainTypeOf_SteamEquipment, &
IntGainTypeOf_OtherEquipment, &
IntGainTypeOf_ZoneBaseboardOutdoorTemperatureControlled, &
IntGainTypeOf_GeneratorFuelCell, &
IntGainTypeOf_WaterUseEquipment, &
IntGainTypeOf_GeneratorMicroCHP, &
IntGainTypeOf_ElectricLoadCenterTransformer, &
IntGainTypeOf_ElectricLoadCenterInverterSimple, &
IntGainTypeOf_ElectricLoadCenterInverterFunctionOfPower, &
IntGainTypeOf_ElectricLoadCenterInverterLookUpTable, &
IntGainTypeOf_ElectricLoadCenterStorageBattery, &
IntGainTypeOf_ElectricLoadCenterStorageSimple, &
IntGainTypeOf_PipeIndoor, &
IntGainTypeOf_RefrigerationCase, &
IntGainTypeOf_RefrigerationCompressorRack, &
IntGainTypeOf_RefrigerationSystemAirCooledCondenser ,&
IntGainTypeOf_RefrigerationSystemSuctionPipe, &
IntGainTypeOf_RefrigerationSecondaryReceiver, &
IntGainTypeOf_RefrigerationSecondaryPipe, &
IntGainTypeOf_RefrigerationWalkIn/)
INTEGER, DIMENSION(2) :: IntGainTypesMixedSubzone = (/IntGainTypeOf_DaylightingDeviceTubular , &
IntGainTypeOf_Lights/)
REAL(r64) :: RetAirGain
! Exact solution or Euler method
If (ZoneAirSolutionAlgo .NE. Use3rdOrder) Then
If (ShortenTimeStepSysRoomAir .and. TimeStepSys .LT. TimeStepZone) Then
If (PreviousTimeStep < TimeStepZone) Then
Zone1Floor(ZoneNum) = ZoneM2Floor(ZoneNum)
Zone1OC(ZoneNum) = ZoneM2OC(ZoneNum)
Zone1MX(ZoneNum) = ZoneM2MX(ZoneNum)
Else
Zone1Floor(ZoneNum) = ZoneMXFloor(ZoneNum)
Zone1OC(ZoneNum) = ZoneMXOC(ZoneNum)
Zone1MX(ZoneNum) = ZoneMXMX(ZoneNum)
End If
Else
Zone1Floor(ZoneNum) = ZTFLOOR(ZoneNum)
Zone1OC(ZoneNum) = ZTOC(ZoneNum)
Zone1MX(ZoneNum) = ZTMX(ZoneNum)
End If
End If
MIXFLAG = .FALSE.
Flagapertures=1
DVHcIn = HConvIn
CeilingHeight = ZoneCeilingHeight((ZoneNum-1)*2 + 2) - ZoneCeilingHeight((ZoneNum-1)*2 + 1)
ZoneMult = Zone(ZoneNum)%Multiplier * Zone(ZoneNum)%ListMultiplier
DO Ctd=1,TotUCSDDV
IF(ZoneNum == ZoneUCSDDV(Ctd)%ZonePtr) THEN
GainsFrac = GetCurrentScheduleValue(ZoneUCSDDV(Ctd)%SchedGainsPtr)
NumPLPP = ZoneUCSDDV(Ctd)%NumPlumesPerOcc
HeightThermostat = ZoneUCSDDV(Ctd)%ThermostatHeight
HeightComfort = ZoneUCSDDV(Ctd)%ComfortHeight
TempDiffCritRep = ZoneUCSDDV(Ctd)%TempTrigger
ENDIF
ENDDO
CALL SumInternalConvectionGainsByTypes(ZoneNum, IntGainTypesOccupied, ConvGainsOccupiedSubzone)
ConvGainsOccupiedSubzone = ConvGainsOccupiedSubzone &
+ 0.5d0*SysDepZoneLoadsLagged(ZoneNum)
! Add heat to return air if zonal system (no return air) or cycling system (return air frequently very
! low or zero)
IF (Zone(ZoneNum)%NoHeatToReturnAir) THEN
CALL SumReturnAirConvectionGainsByTypes(ZoneNum,IntGainTypesOccupied, RetAirGain )
ConvGainsOccupiedSubzone = ConvGainsOccupiedSubzone + RetAirGain
END IF
CALL SumInternalConvectionGainsByTypes(ZoneNum, IntGainTypesMixedSubzone, ConvGainsMixedSubzone)
ConvGainsMixedSubzone = ConvGainsMixedSubzone + SumConvHTRadSys(ZoneNum) &
+ 0.5d0*SysDepZoneLoadsLagged(ZoneNum)
IF (Zone(ZoneNum)%NoHeatToReturnAir) THEN
CALL SumReturnAirConvectionGainsByTypes(ZoneNum, IntGainTypesMixedSubzone, RetAirGain)
ConvGainsMixedSubzone = ConvGainsMixedSubzone + RetAirGain
END IF
ConvGains = ConvGainsOccupiedSubzone + ConvGainsMixedSubzone
!=================== Entering air system temperature and flow====================
SumSysMCp = 0.0d0
SumSysMCpT = 0.0d0
! Check to make sure if this is a controlled zone and determine ZoneEquipConfigNum
ZoneEquipConfigNum = ZoneNum
IF (ZoneEquipConfig(ZoneEquipConfigNum)%IsControlled) THEN
DO NodeNum = 1,ZoneEquipConfig(ZoneEquipConfigNum)%NumInletNodes
NodeTemp = Node(ZoneEquipConfig(ZoneEquipConfigNum)%InletNode(NodeNum))%Temp
MassFlowRate = Node(ZoneEquipConfig(ZoneEquipConfigNum)%InletNode(NodeNum))%MassFlowRate
CpAir = PsyCpAirFnWTdb(ZoneAirHumRat(ZoneNum), NodeTemp)
SumSysMCp = SumSysMCp + MassFlowRate * CpAir
SumSysMCpT = SumSysMCpT + MassFlowRate * CpAir * NodeTemp
ENDDO
ENDIF
SumMCp = MCPI(ZoneNum) + MCPV(ZoneNum) + MCPM(ZoneNum) + MCPE(ZoneNum) + MCPC(ZoneNum) + MdotCPOA(ZoneNum)
SumMCpT = MCPTI(ZoneNum) + MCPTV(ZoneNum) + MCPTM(ZoneNum) + MCPTE(ZoneNum) + MCPTC(ZoneNum) + &
MdotCPOA(ZoneNum)*Zone(ZoneNum)%OutDryBulbTemp
if (SimulateAirflowNetwork == AirflowNetworkControlMultizone) then
SumMCp = AirflowNetworkExchangeData(ZoneNum)%SumMCp+AirflowNetworkExchangeData(ZoneNum)%SumMMCp
SumMCpT = AirflowNetworkExchangeData(ZoneNum)%SumMCpT+AirflowNetworkExchangeData(ZoneNum)%SumMMCpT
end if
MCP_Total = SumMCp + SumSysMCp
MCpT_Total = SumMCpT + SumSysMCpT
IF (TotPeople > 0) THEN
NumberOfOccupants = 0
NumberOfPlumes = 0.0d0
DO Ctd = 1,TotPeople
IF(People(Ctd)%ZonePtr == ZoneNum) THEN
NumberOfOccupants = NumberOfOccupants + People(Ctd)%NumberOfPeople ! *GetCurrentScheduleValue(People(Ctd)%NumberOfPeoplePtr)
NumberOfPlumes = NumberOfOccupants*NumPLPP
ENDIF
ENDDO
IF (NumberOfPlumes == 0.0d0) THEN
NumberOfPlumes = 1.0d0
ENDIF
PowerInPlumes = (1.0d0-GainsFrac)*ConvGainsOccupiedSubzone
PowerPerPlume = PowerInPlumes/NumberOfPlumes
ELSE
NumberOfPlumes = 1.0d0
PowerInPlumes = (1.0d0-GainsFrac)*ConvGainsOccupiedSubzone
PowerPerPlume = PowerInPlumes/NumberOfPlumes
ENDIF
! When AirflowNetwork is used verify if bottom apertures are inflowing and upper apertures are
! outflowing. The lower apertures have to be located below 0.8m and the upper apertures
! have to be located above 1.8m.
IF (NumOfLinksMultizone >0) THEN
DO Loop=1, AirflowNetworkSurfaceUCSDCV(ZoneNum,0)
! direct AirflowNetwork surface
IF (surface(MultizoneSurfaceData(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%SurfNum)%zone == ZoneNum) THEN
IF ((SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmax<0.8d0 .and. &
AirflowNetworkLinkSimu(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%VolFlow>0)) THEN
FlagApertures=0
EXIT
END IF
IF (SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmin>1.8d0 .and. &
AirflowNetworkLinkSimu(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%VolFlow2>0) THEN
FlagApertures=0
EXIT
END IF
IF ((SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmin>0.8d0 .and. &
SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmin<1.8d0) .or. &
(SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmax>0.8d0 .and. &
SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmax<1.8d0)) THEN
FlagApertures=0
EXIT
END IF
! indirect AirflowNetwork surface; this is an interzone surface
ELSE
IF (SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmax+ &
zone(Surface(MultizoneSurfaceData(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%SurfNum)%zone)%originz- &
zone(zonenum)%originz<0.8d0 .and. AirflowNetworkLinkSimu(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%VolFlow2>0) THEN
FlagApertures=0
EXIT
END IF
IF (SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmin+ &
zone(Surface(MultizoneSurfaceData(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%SurfNum)%zone)%originz- &
zone(zonenum)%originz>1.8d0 .and. AirflowNetworkLinkSimu(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%VolFlow>0) THEN
FlagApertures=0
EXIT
END IF
IF ((SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmin+ &
zone(Surface(MultizoneSurfaceData(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%SurfNum)%zone)%originz- &
zone(zonenum)%originz>0.8d0 .and. &
SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmin+ &
zone(Surface(MultizoneSurfaceData(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%SurfNum)%zone)%originz- &
zone(zonenum)%originz<1.8d0) .or. &
(SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmax+ &
zone(Surface(MultizoneSurfaceData(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%SurfNum)%zone)%originz- &
zone(zonenum)%originz>0.8d0 .and. &
SurfParametersCVDV(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%Zmax+ &
zone(Surface(MultizoneSurfaceData(AirflowNetworkSurfaceUCSDCV(ZoneNum,Loop))%SurfNum)%zone)%originz- &
zone(zonenum)%originz<1.8d0)) THEN
FlagApertures=0
EXIT
END IF
ENDIF
END DO
ENDIF
IF ((PowerInPlumes .EQ. 0.0d0) .OR. (MCPT_Total .EQ. 0.0d0) .OR. FlagApertures==0) THEN
! The system will mix
HeightFrac = 0.0d0
ELSE
HeightFrac = Min(24.55d0*(MCP_Total*0.000833d0/(NumberOfPlumes*PowerPerPlume**(1.d0/3.d0)))**0.6d0 / CeilingHeight , 1.0d0)
DO Ctd = 1,4
CALL HcUCSDDV(ZoneNum,HeightFrac)
HeightFrac = Min(24.55d0*(MCP_Total*0.000833d0/(NumberOfPlumes*PowerPerPlume**(1.d0/3.d0)))**0.6d0 / CeilingHeight , 1.0d0)
!EPTeam-replaces above (cause diffs) HeightFrac = Min(24.55d0*(MCP_Total*0.000833d0/(NumberOfPlumes*PowerPerPlume**(1.d0/3.d0)))**0.6 / CeilingHeight , 1.0d0)
HeightTransition(ZoneNum) = HeightFrac * CeilingHeight
AIRRATFloor(ZoneNum) = Zone(ZoneNum)%Volume*MIN(HeightTransition(ZoneNum),HeightFloorSubzoneTop) &
/CeilingHeight*ZoneVolCapMultpSens &
*PsyRhoAirFnPbTdbW(OutBaroPress,MATFloor(ZoneNum),ZoneAirHumRat(ZoneNum)) &
*PsyCpAirFnWTdb(ZoneAirHumRat(ZoneNum),MATFloor(ZoneNum))/(TimeStepSys*SecInHour)
AIRRATOC(ZoneNum) = Zone(ZoneNum)%Volume*(HeightTransition(ZoneNum)-MIN(HeightTransition(ZoneNum),0.2d0)) &
/CeilingHeight*ZoneVolCapMultpSens &
*PsyRhoAirFnPbTdbW(OutBaroPress,MATOC(ZoneNum),ZoneAirHumRat(ZoneNum)) &
*PsyCpAirFnWTdb(ZoneAirHumRat(ZoneNum),MATOC(ZoneNum))/(TimeStepSys*SecInHour)
AIRRATMX(ZoneNum) = Zone(ZoneNum)%Volume*(CeilingHeight-HeightTransition(ZoneNum)) &
/CeilingHeight*ZoneVolCapMultpSens &
*PsyRhoAirFnPbTdbW(OutBaroPress,MATMX(ZoneNum),ZoneAirHumRat(ZoneNum)) &
*PsyCpAirFnWTdb(ZoneAirHumRat(ZoneNum),MATMX(ZoneNum))/(TimeStepSys*SecInHour)
IF (UseZoneTimeStepHistory) THEN
ZTM3Floor(ZoneNum) = XM3TFloor(ZoneNum)
ZTM2Floor(ZoneNum) = XM2TFloor(ZoneNum)
ZTM1Floor(ZoneNum) = XMATFloor(ZoneNum)
ZTM3OC(ZoneNum) = XM3TOC(ZoneNum)
ZTM2OC(ZoneNum) = XM2TOC(ZoneNum)
ZTM1OC(ZoneNum) = XMATOC(ZoneNum)
ZTM3MX(ZoneNum) = XM3TMX(ZoneNum)
ZTM2MX(ZoneNum) = XM2TMX(ZoneNum)
ZTM1MX(ZoneNum) = XMATMX(ZoneNum)
ELSE
ZTM3Floor(ZoneNum) = DSXM3TFloor(ZoneNum)
ZTM2Floor(ZoneNum) = DSXM2TFloor(ZoneNum)
ZTM1Floor(ZoneNum) = DSXMATFloor(ZoneNum)
ZTM3OC(ZoneNum) = DSXM3TOC(ZoneNum)
ZTM2OC(ZoneNum) = DSXM2TOC(ZoneNum)
ZTM1OC(ZoneNum) = DSXMATOC(ZoneNum)
ZTM3MX(ZoneNum) = DSXM3TMX(ZoneNum)
ZTM2MX(ZoneNum) = DSXM2TMX(ZoneNum)
ZTM1MX(ZoneNum) = DSXMATMX(ZoneNum)
ENDIF
AirCap = AIRRATFloor(ZoneNum)
TempHistTerm = AirCap*(3.0d0*ZTM1Floor(ZoneNum)-(3.0d0/2.0d0)*ZTM2Floor(ZoneNum)+(1.0d0/3.0d0)*ZTM3Floor(ZoneNum))
TempDepCoef = HA_FLOOR + MCP_Total
TempIndCoef = HAT_FLOOR + MCPT_Total + NonAirSystemResponse(ZoneNum)/ZoneMult
SELECT CASE (ZoneAirSolutionAlgo)
CASE (Use3rdOrder)
ZTFLOOR(ZoneNum) = (TempHistTerm + HAT_FLOOR + MCPT_Total + NonAirSystemResponse(ZoneNum)/ZoneMult) &
/ ((11.0d0/6.0d0)*AirCap + HA_FLOOR + MCP_Total)
CASE (UseAnalyticalSolution)
If (TempDepCoef .eq. 0.0d0) Then ! B=0
ZTFLOOR(ZoneNum) = Zone1Floor(ZoneNum) + TempIndCoef/AirCap
Else
ZTFLOOR(ZoneNum) = (Zone1Floor(ZoneNum)-TempIndCoef/TempDepCoef)*exp(MIN(700.d0,-TempDepCoef/AirCap))+ &
TempIndCoef/TempDepCoef
End If
CASE (UseEulerMethod)
ZTFLOOR(ZoneNum) = (AirCap*Zone1Floor(ZoneNum)+TempIndCoef)/(AirCap+TempDepCoef)
END SELECT
AirCap = AIRRATOC(ZoneNum)
TempHistTerm = AirCap*(3.0d0*ZTM1OC(ZoneNum)-(3.0d0/2.0d0)*ZTM2OC(ZoneNum)+(1.0d0/3.0d0)*ZTM3OC(ZoneNum))
TempDepCoef = HA_OC + MCP_Total
TempIndCoef = ConvGainsOccupiedSubzone*GainsFrac + HAT_OC + ZTFLOOR(ZoneNum)*MCP_Total
SELECT CASE (ZoneAirSolutionAlgo)
CASE (Use3rdOrder)
ZTOC(ZoneNum) = (TempHistTerm + ConvGainsOccupiedSubzone*GainsFrac + HAT_OC + ZTFLOOR(ZoneNum)*MCP_Total) &
/ ((11.0d0/6.0d0)*AirCap + HA_OC + MCP_Total)
CASE (UseAnalyticalSolution)
If (TempDepCoef .eq. 0.0d0) Then ! B=0
ZTOC(ZoneNum) = Zone1OC(ZoneNum) + TempIndCoef/AirCap
Else
If (AirCap .eq. 0.0d0) Then
ZTOC(ZoneNum) = TempIndCoef/TempDepCoef
Else
ZTOC(ZoneNum) = (Zone1OC(ZoneNum)-TempIndCoef/TempDepCoef)*exp(MIN(700.d0,-TempDepCoef/AirCap))+ &
TempIndCoef/TempDepCoef
End If
End If
CASE (UseEulerMethod)
ZTOC(ZoneNum) = (AirCap*Zone1OC(ZoneNum)+TempIndCoef)/(AirCap+TempDepCoef)
END SELECT
AirCap = AIRRATMX(ZoneNum)
TempHistTerm = AirCap*(3.0d0*ZTM1MX(ZoneNum)-(3.0d0/2.0d0)*ZTM2MX(ZoneNum)+(1.0d0/3.0d0)*ZTM3MX(ZoneNum))
TempDepCoef = HA_MX + MCP_Total
TempIndCoef = ConvGainsOccupiedSubzone*(1.0d0-GainsFrac) + ConvGainsMixedSubzone+ HAT_MX + ZTOC(ZoneNum)*MCP_Total
SELECT CASE (ZoneAirSolutionAlgo)
CASE (Use3rdOrder)
ZTMX(ZoneNum) = (TempHistTerm + ConvGainsOccupiedSubzone*(1.0d0-GainsFrac) + ConvGainsMixedSubzone &
+ HAT_MX + ZTOC(ZoneNum)*MCP_Total) &
/ ((11.0d0/6.0d0)*AirCap + HA_MX + MCP_Total)
CASE (UseAnalyticalSolution)
If (TempDepCoef .eq. 0.0d0) Then ! B=0
ZTMX(ZoneNum) = Zone1MX(ZoneNum) + TempIndCoef/AirCap
Else
If (AirCap .eq. 0.0d0) Then
ZTMX(ZoneNum) = TempIndCoef/TempDepCoef
Else
ZTMX(ZoneNum) = (Zone1MX(ZoneNum)-TempIndCoef/TempDepCoef)*exp(MIN(700.d0,-TempDepCoef/AirCap))+ &
TempIndCoef/TempDepCoef
End If
End If
CASE (UseEulerMethod)
ZTMX(ZoneNum) = (AirCap*Zone1MX(ZoneNum)+TempIndCoef)/(AirCap+TempDepCoef)
END SELECT
END DO
! MinFlow for interface layer at z = 1.0
MinFlow = (1.d0/24.55d0*1.0d0)**(1.0d0/0.6d0)*NumberOfPlumes*PowerPerPlume**(1.0d0/3.0d0)
!EPTeam above replaces (cause diffs?) MinFlow = (1.d0/24.55d0*1.0d0)**(1.0d0/0.6d0)*NumberOfPlumes*PowerPerPlume**(1./3.)
IF (MinFlow /= 0.0d0) THEN
FracMinFlow(ZoneNum) = MCP_Total*0.000833d0 / MinFlow
ELSE
FracMinFlow(ZoneNum) = 9.999d0
ENDIF
AirModel(ZoneNum)%SimAirModel = .TRUE.
END IF
!=============================== M I X E D Calculation ==============================================
IF(ZTMX(ZoneNum) < ZTOC(ZoneNum) .or. MCP_Total <= 0.0d0 .or. &
HeightFrac*CeilingHeight < (HeightFloorSubzoneTop + ThickOccupiedSubzoneMin)) THEN
MIXFLAG = .TRUE.
HeightFrac = 0.0d0
AvgTempGrad(ZoneNum) = 0.0d0
MaxTempGrad(ZoneNum) = 0.0d0
AirModel(ZoneNum)%SimAirModel = .FALSE.
AirCap = AIRRAT(ZoneNum)
TempHistTerm = AirCap*(3.0d0*ZTM1(ZoneNum)-(3.0d0/2.0d0)*ZTM2(ZoneNum)+(1.0d0/3.0d0)*ZTM3(ZoneNum))
DO Ctd = 1,3
TempDepCoef = HA_MX + HA_OC + HA_FLOOR + MCP_Total
TempIndCoef = ConvGains + HAT_MX + HAT_OC + HAT_FLOOR + MCpT_Total
SELECT CASE (ZoneAirSolutionAlgo)
CASE (Use3rdOrder)
ZTAveraged = (TempHistTerm + ConvGains + HAT_MX + HAT_OC + HAT_FLOOR + MCpT_Total)/ &
((11.0d0/6.0d0)*AirCap + HA_MX + HA_OC + HA_FLOOR + MCP_Total)
CASE (UseAnalyticalSolution)
If (TempDepCoef .eq. 0.0d0) Then ! B=0
ZTAveraged = ZoneT1(ZoneNum) + TempIndCoef/AirCap
Else
ZTAveraged = (ZoneT1(ZoneNum)-TempIndCoef/TempDepCoef)*exp(MIN(700.d0,-TempDepCoef/AirCap))+ &
TempIndCoef/TempDepCoef
End If
CASE (UseEulerMethod)
ZTAveraged = (AirCap*ZoneT1(ZoneNum)+TempIndCoef)/(AirCap+TempDepCoef)
END SELECT
ZTOC(ZoneNum) = ZTAveraged
ZTMX(ZoneNum) = ZTAveraged
ZTFLOOR(ZoneNum) = ZTAveraged
CALL HcUCSDDV(ZoneNum,HeightFrac)
TempDepCoef = HA_MX + HA_OC + HA_FLOOR + MCP_Total
TempIndCoef = ConvGains + HAT_MX + HAT_OC + HAT_FLOOR + MCpT_Total
SELECT CASE (ZoneAirSolutionAlgo)
CASE (Use3rdOrder)
ZTAveraged = (TempHistTerm + ConvGains + HAT_MX + HAT_OC + HAT_FLOOR + MCpT_Total)/ &
((11.0d0/6.0d0)*AirCap + HA_MX + HA_OC + HA_FLOOR + MCP_Total)
CASE (UseAnalyticalSolution)
If (TempDepCoef .eq. 0.0d0) Then ! B=0
ZTAveraged = ZoneT1(ZoneNum) + TempIndCoef/AirCap
Else
ZTAveraged = (ZoneT1(ZoneNum)-TempIndCoef/TempDepCoef)*exp(MIN(700.d0,-TempDepCoef/AirCap))+ &
TempIndCoef/TempDepCoef
End If
CASE (UseEulerMethod)
ZTAveraged = (AirCap*ZoneT1(ZoneNum)+TempIndCoef)/(AirCap+TempDepCoef)
END SELECT
ZTOC(ZoneNum) = ZTAveraged
ZTMX(ZoneNum) = ZTAveraged
ZTFLOOR(ZoneNum) = ZTAveraged
END DO
END IF
!=========================================================================================
! Comfort temperature and temperature at the thermostat/temperature control sensor
HeightTransition(ZoneNum) = HeightFrac * CeilingHeight
HeightMixedSubzoneAve = (CeilingHeight + HeightTransition(ZoneNum)) / 2.d0
HeightOccupiedSubzoneAve = (HeightFloorSubzoneTop + HeightTransition(ZoneNum)) / 2.d0
HeightFloorSubzoneAve = HeightFloorSubzoneTop / 2.d0
! Comfort temperature
IF (MIXFLAG) THEN
TCMF(ZoneNum) = ZTAveraged
ELSE
IF (HeightComfort >= 0.0d0 .AND. HeightComfort < HeightFloorSubzoneAve) THEN
CALL ShowWarningError ('Displacement ventilation comfort height is in floor subzone in Zone: '//TRIM(Zone(ZoneNum)%Name))
TCMF(ZoneNum) = ZTFloor(ZoneNum)
ELSEIF (HeightComfort >= HeightFloorSubzoneAve .AND. HeightComfort < HeightOccupiedSubzoneAve) THEN
TCMF(ZoneNum) = (ZTFloor(ZoneNum) * (HeightOccupiedSubzoneAve - HeightComfort) &
+ ZTOC(ZoneNum) * (HeightComfort - HeightFloorSubzoneAve)) &
/ (HeightOccupiedSubzoneAve - HeightFloorSubzoneAve)
!! TCMF(ZoneNum) = (ZTFloor(ZoneNum) * (HeightOccupiedSubzoneAve - HeightComfort) &
!! + ZTMX(ZoneNum) * (HeightComfort - HeightFloorSubzoneAve)) &
!! / (HeightOccupiedSubzoneAve - HeightFloorSubzoneAve)
ELSEIF (HeightComfort >= HeightOccupiedSubzoneAve .AND. HeightComfort < HeightMixedSubzoneAve) THEN
TCMF(ZoneNum) = (ZTOC(ZoneNum) * (HeightMixedSubzoneAve - HeightComfort) &
+ ZTMX(ZoneNum) * (HeightComfort - HeightOccupiedSubzoneAve)) &
/ (HeightMixedSubzoneAve - HeightOccupiedSubzoneAve)
ELSEIF (HeightComfort >= HeightMixedSubzoneAve .AND. HeightComfort <= CeilingHeight) THEN
TCMF(ZoneNum) = ZTMX(ZoneNum)
ELSE
CALL ShowFatalError ('Displacement ventilation comfort height is above ceiling or below floor in Zone: '// &
TRIM(Zone(ZoneNum)%Name))
ENDIF
ENDIF
! Temperature at the thermostat/temperature control sensor
IF (MIXFLAG) THEN
TempTstatAir(ZoneNum) = ZTAveraged
ELSE
IF (HeightThermostat >= 0.0d0 .AND. HeightThermostat < HeightFloorSubzoneAve) THEN
CALL ShowWarningError ('Displacement thermostat is in floor subzone in Zone: '//TRIM(Zone(ZoneNum)%Name))
TempTstatAir(ZoneNum) = ZTFloor(ZoneNum)
ELSEIF (HeightThermostat >= HeightFloorSubzoneAve .AND. HeightThermostat < HeightOccupiedSubzoneAve) THEN
TempTstatAir(ZoneNum) = (ZTFloor(ZoneNum) * (HeightOccupiedSubzoneAve - HeightThermostat) &
+ ZTOC(ZoneNum) * (HeightThermostat - HeightFloorSubzoneAve)) &
/ (HeightOccupiedSubzoneAve - HeightFloorSubzoneAve)
!! TempTstatAir(ZoneNum) = (ZTFloor(ZoneNum) * (HeightOccupiedSubzoneAve - HeightThermostat) &
!! + ZTMX(ZoneNum) * (HeightThermostat - HeightFloorSubzoneAve)) &
!! / (HeightOccupiedSubzoneAve - HeightFloorSubzoneAve)
ELSEIF (HeightThermostat >= HeightOccupiedSubzoneAve .AND. HeightThermostat < HeightMixedSubzoneAve) THEN
TempTstatAir(ZoneNum) = (ZTOC(ZoneNum) * (HeightMixedSubzoneAve - HeightThermostat) &
+ ZTMX(ZoneNum) * (HeightThermostat - HeightOccupiedSubzoneAve)) &
/ (HeightMixedSubzoneAve - HeightOccupiedSubzoneAve)
ELSEIF (HeightThermostat >= HeightMixedSubzoneAve .AND. HeightThermostat <= CeilingHeight) THEN
TempTstatAir(ZoneNum) = ZTMX(ZoneNum)
ELSE
CALL ShowFatalError ('Displacement ventilation thermostat height is above ceiling or below floor in Zone: '// &
TRIM(Zone(ZoneNum)%Name))
ENDIF
ENDIF
! Temperature gradients
IF ((HeightMixedSubzoneAve - HeightFloorSubzoneAve) > 0.1d0) THEN
AvgTempGrad(ZoneNum) = (ZTMX(ZoneNum) - ZTFLOOR(ZoneNum))/(HeightMixedSubzoneAve - HeightFloorSubzoneAve)
ELSE
AvgTempGrad(ZoneNum) = -9.999d0
ENDIF
IF ((HeightOccupiedSubzoneAve - HeightFloorSubzoneAve) > 0.1d0) THEN
MaxTempGrad(ZoneNum) = (ZTOC(ZoneNum) - ZTFLOOR(ZoneNum))/(HeightOccupiedSubzoneAve - HeightFloorSubzoneAve)
ELSE
MaxTempGrad(ZoneNum) = -9.999d0
ENDIF
IF ((HeightMixedSubzoneAve - HeightOccupiedSubzoneAve) > 0.1d0) THEN
MTGAUX = (ZTMX(ZoneNum)-ZTOC(ZoneNum))/(HeightMixedSubzoneAve - HeightOccupiedSubzoneAve)
ELSE
MTGAUX = -9.999d0
ENDIF
IF (MTGAUX > MaxTempGrad(ZoneNum)) THEN
MaxTempGrad(ZoneNum) = MTGAUX
ENDIF
IF (MIXFLAG) THEN
ZoneDVMixedFlag(ZoneNum) = 1
AirModel(ZoneNum)%SimAirModel = .FALSE.
ELSE
ZoneDVMixedFlag(ZoneNum) = 0
AirModel(ZoneNum)%SimAirModel = .TRUE.
ENDIF
IF (ZoneEquipConfig(ZoneNum)%IsControlled) THEN
ZoneNodeNum = Zone(ZoneNum)%SystemZoneNodeNumber
Node(ZoneNodeNum)%Temp = ZTMX(ZoneNum)
ENDIF
! Mixed for reporting purposes
IF ((MIXFLAG) .OR. ((ZTMX(ZoneNum)-ZTOC(ZoneNum)).LT.TempDiffCritRep)) THEN
ZoneDVMixedFlagRep(ZoneNum) = 1.d0
FracMinFlow(ZoneNum) = -1.0d0
HeightTransition(ZoneNum) = -9.999d0
AvgTempGrad(ZoneNum) = -9.999d0
MaxTempGrad(ZoneNum) = -9.999d0
ELSE
ZoneDVMixedFlagRep(ZoneNum) = 0.0d0
ENDIF
END SUBROUTINE CalcUCSDDV