Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
integer, | intent(in) | :: | BaseboardTypeNum | |||
character(len=*), | intent(in) | :: | BaseboardName | |||
integer, | intent(in) | :: | EquipFlowCtrl | |||
integer, | intent(in) | :: | LoopNum | |||
integer, | intent(in) | :: | LoopSide | |||
integer, | intent(inout) | :: | CompIndex | |||
logical, | intent(in) | :: | FirstHVACIteration | |||
logical, | intent(inout) | :: | InitLoopEquip |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE UpdateHWBaseboardPlantConnection(BaseboardTypeNum, &
BaseboardName,&
EquipFlowCtrl, &
LoopNum,LoopSide,CompIndex,&
FirstHVACIteration, InitLoopEquip)
! SUBROUTINE INFORMATION:
! AUTHOR Brent Griffith
! DATE WRITTEN Sept. 2010
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! update sim routine called from plant
! METHODOLOGY EMPLOYED:
! check input, provide comp index, call utility routines
! REFERENCES:
! na
! USE STATEMENTS:
USE PlantUtilities , ONLY: PullCompInterconnectTrigger
USE DataPlant, ONLY: ccSimPlantEquipTypes, TypeOf_Baseboard_Rad_Conv_Water, &
CriteriaType_MassFlowRate, CriteriaType_Temperature, CriteriaType_HeatTransferRate
USE InputProcessor, ONLY: FindItemInList
USE General, ONLY: TrimSigDigits
USE DataGlobals, ONLY: KickOffSimulation
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER, INTENT(IN) :: BaseboardTypeNum ! type index
CHARACTER(len=*), INTENT(IN) :: BaseboardName ! component name
INTEGER, INTENT(IN) :: EquipFlowCtrl ! Flow control mode for the equipment
INTEGER, INTENT(IN) :: LoopNum ! Plant loop index for where called from
INTEGER, INTENT(IN) :: LoopSide ! Plant loop side index for where called from
INTEGER, INTENT(INOUT) :: CompIndex ! Chiller number pointer
LOGICAL , INTENT(IN) :: FirstHVACIteration
LOGICAL, INTENT(INOUT) :: InitLoopEquip ! If not zero, calculate the max load for operating conditions
INTEGER :: BaseboardNum
INTEGER :: InletNodeNum
INTEGER :: OutletNodeNum
! Find the correct baseboard
IF (CompIndex == 0) THEN
BaseboardNum = FindItemInList(BaseboardName,HWBaseboard%EquipID,NumHWBaseboards)
IF (BaseboardNum == 0) THEN
CALL ShowFatalError('UpdateHWBaseboardPlantConnection: Specified baseboard not valid ='//TRIM(BaseboardName))
ENDIF
CompIndex=BaseboardNum
ELSE
BaseboardNum=CompIndex
IF (BaseboardNum > NumHWBaseboards .or. BaseboardNum < 1) THEN
CALL ShowFatalError('UpdateHWBaseboardPlantConnection: Invalid CompIndex passed='// &
TRIM(TrimSigDigits(BaseboardNum))// &
', Number of baseboards='//TRIM(TrimSigDigits(NumHWBaseboards))// &
', Entered baseboard name='//TRIM(BaseboardName))
ENDIF
IF (KickOffSimulation) THEN
IF (BaseboardName /= HWBaseboard(BaseboardNum)%EquipID) THEN
CALL ShowFatalError('UpdateHWBaseboardPlantConnection: Invalid CompIndex passed='// &
TRIM(TrimSigDigits(BaseboardNum))// &
', baseboard name='//TRIM(BaseboardName)//', stored baseboard Name for that index='// &
TRIM(HWBaseboard(BaseboardNum)%EquipID))
ENDIF
IF (BaseboardTypeNum /= TypeOf_Baseboard_Rad_Conv_Water) THEN
CALL ShowFatalError('UpdateHWBaseboardPlantConnection: Invalid CompIndex passed='// &
TRIM(TrimSigDigits(BaseboardNum))// &
', baseboard name='//TRIM(BaseboardName)//', stored baseboard Name for that index='// &
TRIM(ccSimPlantEquipTypes(BaseboardTypeNum)) )
ENDIF
ENDIF
ENDIF
IF (InitLoopEquip) THEN
RETURN
END IF
CALL PullCompInterconnectTrigger(HWBaseboard(BaseboardNum)%LoopNum, &
HWBaseboard(BaseboardNum)%LoopSideNum, &
HWBaseboard(BaseboardNum)%BranchNum, &
HWBaseboard(BaseboardNum)%CompNum, &
HWBaseboard(BaseboardNum)%BBLoadReSimIndex, &
HWBaseboard(BaseboardNum)%LoopNum, &
HWBaseboard(BaseboardNum)%LoopSideNum, &
CriteriaType_HeatTransferRate, &
HWBaseboard(BaseboardNum)%Power)
CALL PullCompInterconnectTrigger(HWBaseboard(BaseboardNum)%LoopNum, &
HWBaseboard(BaseboardNum)%LoopSideNum, &
HWBaseboard(BaseboardNum)%BranchNum, &
HWBaseboard(BaseboardNum)%CompNum, &
HWBaseboard(BaseboardNum)%BBMassFlowReSimIndex, &
HWBaseboard(BaseboardNum)%LoopNum, &
HWBaseboard(BaseboardNum)%LoopSideNum, &
CriteriaType_MassFlowRate, &
HWBaseboard(BaseboardNum)%WaterMassFlowRate)
CALL PullCompInterconnectTrigger(HWBaseboard(BaseboardNum)%LoopNum, &
HWBaseboard(BaseboardNum)%LoopSideNum, &
HWBaseboard(BaseboardNum)%BranchNum, &
HWBaseboard(BaseboardNum)%CompNum, &
HWBaseboard(BaseboardNum)%BBInletTempFlowReSimIndex, &
HWBaseboard(BaseboardNum)%LoopNum, &
HWBaseboard(BaseboardNum)%LoopSideNum, &
CriteriaType_Temperature, &
HWBaseboard(BaseboardNum)%WaterOutletTemp)
RETURN
END SUBROUTINE UpdateHWBaseboardPlantConnection