Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
logical | :: | FirstHVACIteration | ||||
logical | :: | SimZone | ||||
logical | :: | SimAir |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE ManageZoneEquipment(FirstHVACIteration,SimZone,SimAir)
! SUBROUTINE INFORMATION:
! AUTHOR Russ Taylor
! DATE WRITTEN May 1997
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! Calls the zone thermal control simulations and the interfaces
! (water-air, refrigerant-air, steam-air, electric-electric,
! water-water, etc)
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
LOGICAL FirstHVACIteration
LOGICAL SimZone
LOGICAL SimAir
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
IF (GetZoneEquipmentInputFlag) THEN
CALL GetZoneEquipment
GetZoneEquipmentInputFlag = .FALSE.
ZoneEquipInputsFilled=.true.
END IF
CALL InitZoneEquipment(FirstHVACIteration)
IF (ZoneSizingCalc) THEN
CALL SizeZoneEquipment
ELSE
CALL SimZoneEquipment(FirstHVACIteration, SimAir)
ZoneEquipSimulatedOnce = .TRUE.
END IF
CALL UpdateZoneEquipment(SimAir)
CALL ReportZoneEquipment
SimZone = .False.
RETURN
END SUBROUTINE ManageZoneEquipment