Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE SetupThermostatActuators
! SUBROUTINE INFORMATION:
! AUTHOR Brent Griffith
! DATE WRITTEN May 2009
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! Make zone thermostats, humidistats, and comfort controls available to EMS
! METHODOLOGY EMPLOYED:
! Loop over structures and call SetupEMSactuator for public data in DataZoneControls.
! REFERENCES:
! na
! USE STATEMENTS:
USE DataZoneControls
USE DataInterfaces, ONLY: SetupEMSActuator
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: Loop = 0 ! local do loop index
DO Loop = 1, NumTempControlledZones
CALL SetupEMSActuator('Zone Temperature Control', TempControlledZone(loop)%ZoneName, &
'Heating Setpoint', '[C]', &
TempControlledZone(loop)%EMSOverrideHeatingSetpointOn, &
TempControlledZone(loop)%EMSOverrideHeatingSetpointValue)
CALL SetupEMSActuator('Zone Temperature Control', TempControlledZone(loop)%ZoneName, &
'Cooling Setpoint', '[C]', &
TempControlledZone(loop)%EMSOverrideCoolingSetpointOn, &
TempControlledZone(loop)%EMSOverrideCoolingSetpointValue)
ENDDO
DO Loop = 1, NumHumidityControlZones
CALL SetupEMSActuator('Zone Humidity Control', HumidityControlZone(loop)%ZoneName, &
'Relative Humidity Humidifying Setpoint', '[%]', &
HumidityControlZone(loop)%EMSOverrideHumidifySetpointOn, &
HumidityControlZone(loop)%EMSOverrideHumidifySetpointValue)
CALL SetupEMSActuator('Zone Humidity Control', HumidityControlZone(loop)%ZoneName, &
'Relative Humidity Dehumidifying Setpoint', '[%]', &
HumidityControlZone(loop)%EMSOverrideDehumidifySetpointOn, &
HumidityControlZone(loop)%EMSOverrideDehumidifySetpointValue)
ENDDO
DO Loop = 1, NumComfortControlledZones
CALL SetupEMSActuator('Zone Comfort Control', ComfortControlledZone(loop)%ZoneName, &
'Heating Setpoint', '[]', &
ComfortControlledZone(loop)%EMSOverrideHeatingSetpointOn, &
ComfortControlledZone(loop)%EMSOverrideHeatingSetpointValue)
CALL SetupEMSActuator('Zone Comfort Control', ComfortControlledZone(loop)%ZoneName, &
'Cooling Setpoint', '[]', &
ComfortControlledZone(loop)%EMSOverrideCoolingSetpointOn, &
ComfortControlledZone(loop)%EMSOverrideCoolingSetpointValue)
ENDDO
RETURN
END SUBROUTINE SetupThermostatActuators