Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
integer, | intent(in) | :: | OAUnitNum |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE ReportOutdoorAirUnit(OAUnitNum)
! SUBROUTINE INFORMATION:
! AUTHOR Young T. Chae
! DATE WRITTEN Oct. 2009
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! This subroutine simply produces output for the outdoor air unit.
! METHODOLOGY EMPLOYED:
! Standard EnergyPlus methodology.
! REFERENCES:
! na
! USE STATEMENTS:
USE DataGlobals, ONLY : SecInHour
USE DataHeatBalance, ONLY : Zone
USE DataHVACGlobals, ONLY : TimeStepSys
USE DataLoopNode, ONLY : Node
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
INTEGER, INTENT(IN) :: OAUnitNum ! Index for the outdoor air unit under consideration within the derived types
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! FLOW:
OutAirUnit(OAUnitNum)%TotHeatingEnergy = OutAirUnit(OAUnitNum)%TotHeatingRate*TimeStepSys*SecInHour
OutAirUnit(OAUnitNum)%SensHeatingEnergy = OutAirUnit(OAUnitNum)%SensHeatingRate*TimeStepSys*SecInHour
OutAirUnit(OAUnitNum)%LatHeatingEnergy = OutAirUnit(OAUnitNum)%LatHeatingRate*TimeStepSys*SecInHour
OutAirUnit(OAUnitNum)%SensCoolingEnergy = OutAirUnit(OAUnitNum)%SensCoolingRate*TimeStepSys*SecInHour
OutAirUnit(OAUnitNum)%LatCoolingEnergy = OutAirUnit(OAUnitNum)%LatCoolingRate*TimeStepSys*SecInHour
OutAirUnit(OAUnitNum)%TotCoolingEnergy = OutAirUnit(OAUnitNum)%TotCoolingRate*TimeStepSys*SecInHour
OutAirUnit(OAUnitNum)%AirMassFlow = OutAirUnit(OAUnitNum)%OutAirMassFlow
OutAirUnit(OAUnitNum)%ElecFanEnergy = OutAirUnit(OAUnitNum)%ElecFanRate*TimeStepSys*SecInHour
RETURN
END SUBROUTINE ReportOutdoorAirUnit