Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
character(len=*), | intent(in) | :: | HeatingCoilName | |||
integer, | intent(inout) | :: | HeatingCoilIndex | |||
logical, | intent(inout) | :: | ErrorsFound |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE GetCoilIndex(HeatingCoilName,HeatingCoilIndex,ErrorsFound)
! SUBROUTINE INFORMATION:
! AUTHOR Richard Raustad
! DATE WRITTEN March 2005
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! This subroutine sets an index for a given DX Coil -- issues error message if that
! DX Coil is not a legal DX Coil.
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: FindItem
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
CHARACTER(len=*), INTENT(IN) :: HeatingCoilName
INTEGER, INTENT(INOUT) :: HeatingCoilIndex
LOGICAL, INTENT(INOUT) :: ErrorsFound
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
! Obtains and Allocates HeatingCoil related parameters from input file
IF (GetCoilsInputFlag) THEN !First time subroutine has been entered
CALL GetHeatingCoilInput
GetCoilsInputFlag=.false.
End If
HeatingCoilIndex = FindItem(HeatingCoilName,HeatingCoil%Name,NumHeatingCoils)
IF (HeatingCoilIndex == 0) THEN
CALL ShowSevereError('GetCoilIndex: Heating coil not found='//TRIM(HeatingCoilName))
ErrorsFound = .TRUE.
ENDIF
RETURN