Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
character(len=*), | intent(in) | :: | UnitarySystemName | |||
logical, | intent(inout), | optional | :: | OACoolingCoil | ||
logical, | intent(inout), | optional | :: | OAHeatingCoil |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
SUBROUTINE GetUnitarySystemOAHeatCoolCoil(UnitarySystemName, OACoolingCoil, OAHeatingCoil)
! FUNCTION INFORMATION:
! AUTHOR Chandan Sharma
! DATE WRITTEN April 2013
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS FUNCTION:
! Determined weather Unitary system in OA stream has heating or cooling coils
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: SameString
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! FUNCTION ARGUMENT DEFINITIONS:
CHARACTER(len=*), INTENT(IN) :: UnitarySystemName ! Name of Unitary System object
LOGICAL, INTENT(INOUT), OPTIONAL :: OACoolingCoil ! Cooling coil in OA stream
LOGICAL, INTENT(INOUT), OPTIONAL :: OAHeatingCoil ! Heating coil in OA stream
! FUNCTION PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! FUNCTION LOCAL VARIABLE DECLARATIONS:
INTEGER :: UnitarySysNum
IF (GetInputFlag) THEN !First time subroutine has been entered
CALL GetUnitarySystemInput
GetInputFlag=.false.
END IF
DO UnitarySysNum = 1, NumUnitarySystem
IF(SameString(UnitarySystemName,UnitarySystem(UnitarySysNum)%Name))THEN
IF (UnitarySystem(UnitarySysNum)%CoolCoilExists) THEN
OACoolingCoil = .TRUE.
END IF
IF (UnitarySystem(UnitarySysNum)%HeatCoilExists .OR. &
UnitarySystem(UnitarySysNum)%SuppCoilExists) THEN
OAHeatingCoil = .TRUE.
END IF
END IF
END DO
RETURN
END SUBROUTINE GetUnitarySystemOAHeatCoolCoil