Nodes of different colours represent the following:
Solid arrows point from a parent (sub)module to the submodule which is descended from it. Dashed arrows point from a module being used to the module or program unit using it. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
character(len=*), | intent(in) | :: | SplitterName | |||
integer, | intent(in) | :: | SplitterNum | |||
logical, | intent(inout) | :: | ErrorsFound |
Nodes of different colours represent the following:
Solid arrows point from a procedure to one which it calls. Dashed arrows point from an interface to procedures which implement that interface. This could include the module procedures in a generic interface or the implementation in a submodule of an interface in a parent module. Where possible, edges connecting nodes are given different colours to make them easier to distinguish in large graphs.
FUNCTION GetSplitterOutletNumber(SplitterName,SplitterNum,ErrorsFound) RESULT(SplitterOutletNumber)
! FUNCTION INFORMATION:
! AUTHOR Lixing Gu
! DATE WRITTEN Feb 2013
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS FUNCTION:
! This function looks up the given AirLoopHVAC:ZoneSplitter and returns the number of outlet nodes. If
! incorrect AirLoopHVAC:ZoneSplitter name is given, errorsfound is returned as true
! as zero.
! METHODOLOGY EMPLOYED:
! na
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: FindItemInList
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! FUNCTION ARGUMENT DEFINITIONS:
CHARACTER(len=*), INTENT(IN) :: SplitterName ! must match Splitter names for the Splitter type
INTEGER, INTENT(IN) :: SplitterNum ! Index of Splitters
LOGICAL, INTENT(INOUT) :: ErrorsFound ! set to true if problem
! FUNCTION PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! FUNCTION LOCAL VARIABLE DECLARATIONS:
INTEGER :: WhichSplitter, SplitterOutletNumber
! Obtains and Allocates AirLoopHVAC:ZoneSplitter related parameters from input file
IF (GetSplitterInputFlag) THEN !First time subroutine has been entered
CALL GetSplitterInput
GetSplitterInputFlag=.false.
End If
If (SplitterNum .EQ. 0) Then
WhichSplitter = FindItemInList(SplitterName,SplitterCond%SplitterName,NumSplitters)
Else
WhichSplitter = SplitterNum
End If
IF (WhichSplitter /= 0) THEN
SplitterOutletNumber = SplitterCond(WhichSplitter)%NumOutletNodes
ENDIF
IF (WhichSplitter == 0) THEN
CALL ShowSevereError('GetSplitterOuletNumber: Could not find Splitter = "'//TRIM(SplitterName)//'"')
ErrorsFound=.true.
SplitterOutletNumber = 0
ENDIF
RETURN
END FUNCTION GetSplitterOutletNumber